A new version of the data type is present than one required

Hi  Experts,
I am getting a short dump saying "A new version of the data type is present than one required".
The data type in my case is the Transfer structure for 2LIS_02_SCL. I am getting this short dump whenever i try to change the transfer rules.
I tried activating and deactivating the transfer and update rules but to no avail. Kindly advice.
Thanks in advance.

SAP Note 1157796 resolved the issue.

Similar Messages

  • Error:  A newer version of data type was found than one required

    Hi Experts,
    we made a changes to a table and then transported the table to the quality system. But a program which is referring to this table, results in dump with the below error message.
    Error Message>>>>>>>>>>" A newer version of data type <TABLE> was found than one required "
    The issue occures inspite of
    1. re-activated the table and send to quality system
    2. Re-activated the program
    3. Activated and adjusted database in SE14.
    Please let me know the correction to be taken to resolve the issue.
    Regards
    Suresh Kumar

    This happens when you modify your new data element, domain while another program is currently using it.
    Simply get out completely of the program, re activate the program, reactivate the table. You might need to run se14 to convert the database table but this does not happen frequently. Try first to reactivate the program
    Dean
    Edited by: Dean Ton on Mar 8, 2012 9:54 PM
    Edited by: Dean Ton on Mar 8, 2012 9:56 PM

  • When to expect a new version of the Data Modelling tool ?

    Hello,
    just a quick question - what's the time horizon for the new version ? and where ( if at all ) can i see the list of bugs/features to be addressed in it ?
    Thank you.
    Andrew
    Edited by: andrey on Jan 16, 2009 8:40 AM

    Hello,
    what is soon? Do you know exact date or month?
    Thank you
    Regards
    Martin

  • Dump-A newer version of data type "ZMNFLOCK" was found than one required

    Hi,
    I am getting dump in program when there is a select query on ZMNFLOCK table.
    Error analsys is given as
    Error analysis                                                                               
    The data type "ZMNFLOCK" was loaded from the database during the program run.                 
        However, a type of a newer version than the one requried was found here.   
    What could be the problem? my BASIS person says this is somewhere related to ABAP.
    should i Adjust & Activate database by going to SE14 for ZMNFLOCK table.
    Also noted that error is random in nature and its not coming everytime.

    Hi,
    There could be an issue with in the table, As Dataelement or domain related to any field in table may have changed, And that field is not getting used aal the time, That's why Dump is coming randomly.
    The best possible solution is to Activate and adjust database table through SE14, This will update table with all the updated versions.
    Thanks
    Saurabh Siwach

  • A newer version of data type BBP_PDS_HSS_IC was found than one required

    Hi,
    When I create a SC, it is automatically approved but the PO is not created.
    If I check TRX SM58 I get the message:
    "A newer version of data type BBP_PDS_HSS_IC was found than one required"
    Any ideas?
    Carlos Durazo

    Hi
    Which SRM version are you using ?
    By an chance have you created any new fields in the standard structure
    <b>'BBP_PDS_HSS_IC'</b> using <u>SE11</u> Transaction in SRM system. Please confirm the same by taking help of ABAP person here. Seems to be like the structure is not Activated completed. 
    <u>Related SAP OSS Notes -></u>
    Note 758067 - SRM 4.0: Change documents of new sets (DynAttr, Weight)
    Note 820201 - Document changes for attachments does not work
    Hinweis 691880 - Changes in tolerances not displayed in purchase order
    Note 1018714 - Change documents: Time stamp of the application server
    Note 1006898 - Deleted vendor not displayed in Change hist of Shopping cart
    Do let me know.
    Regards
    - Atul

  • Newer version of the zen xt

    In a older thread someone said something about a newer version of the zen xtra with a fixed headphone jack and I was just wondering when the "newer version" of the zen xtra came out.

    I can't remember the exact date, but it seemed to coincide with a change in packaging. From the box to the plastic blister type package, with a case that has a cut-out for the window. No guarantee that one in this package has the reinforced headphone jack though.

  • Any idea what this errorr means? the data type of the reference does not match the data type of the variable

    I am using Veristand 2014, Scan Engine and EtherCat Custom Device.  I have not had this error before, but I was trying to deploy my System Definition File (run) to the Target (cRio 9024 with 6 modules) and it failed. It wouldn't even try to communicate with the target. I get the 'connection refused' error.  
    I created a new Veristand project
    I added the Scan Engine and EtherCat custom device.
    I changed the IP address and auto-detected my modules
    i noticed tat Veristand didn't find one of my modules that was there earlier. (this week)
     So, i went to NiMax to make sure software was installed and even reinstalled Scan Engine and Veristand just to make sure.
    Now, it finds the module, but when i go to deploy it getsto the last step of deploying the code to the target, and then it fails.
    Any thoughts?
    Start Date: 4/10/2015 11:48 AM
    • Loading System Definition file: C:\Users\Public\Documents\National Instruments\NI VeriStand 2014\Projects\testChassis\testChassis.nivssdf
    • Initializing TCP subsystem...
    • Starting TCP Loops...
    • Connection established with target Controller.
    • Preparing to synchronize with targets...
    • Querying the active System Definition file from the targets...
    • Stopping TCP loops.
    Waiting for TCP loops to shut down...
    • TCP loops shut down successfully.
    • Unloading System Definition file...
    • Connection with target Controller has been lost.
    • Start Date: 4/10/2015 11:48 AM
    • Loading System Definition file: C:\Users\Public\Documents\National Instruments\NI VeriStand 2014\Projects\testChassis\testChassis.nivssdf
    • Preparing to deploy the System Definition to the targets...
    • Compiling the System Definition file...
    • Initializing TCP subsystem...
    • Starting TCP Loops...
    • Connection established with target Controller.
    • Sending reset command to all targets...
    • Preparing to deploy files to the targets...
    • Starting download for target Controller...
    • Opening FTP session to IP 10.12.0.48...
    • Processing Action on Deploy VIs...
    • Setting target scan rate to 10000 (uSec)... Done.
    • Gathering target dependency files...
    • Downloading testChassis.nivssdf [92 kB] (file 1 of 4)
    • Downloading testChassis_Controller.nivsdat [204 kB] (file 2 of 4)
    • Downloading CalibrationData.nivscal [0 kB] (file 3 of 4)
    • Downloading testChassis_Controller.nivsparam [0 kB] (file 4 of 4)
    • Closing FTP session...
    • Files successfully deployed to the targets.
    • Starting deployment group 1...
    The VeriStand Gateway encountered an error while deploying the System Definition file.
    Details:
    Error -66212 occurred at Project Window.lvlibroject Window.vi >> Project Window.lvlib:Command Loop.vi >> NI_VS Workspace ExecutionAPI.lvlib:NI VeriStand - Connect to System.vi
    Possible reason(s):
    LabVIEW: The data type of the reference does not match the data type of the variable.
    =========================
    NI VeriStand: NI VeriStand Engine.lvlib:VeriStand Engine Wrapper (RT).vi >> NI VeriStand Engine.lvlib:VeriStand Engine.vi >> NI VeriStand Engine.lvlib:VeriStand Engine State Machine.vi >> NI VeriStand Engine.lvlib:Initialize Inline Custom Devices.vi >> Custom Devices Storage.lvlib:Initialize Device (HW Interface).vi
    • Sending reset command to all targets...
    • Stopping TCP loops.
    Waiting for TCP loops to shut down...
    • TCP loops shut down successfully.
    • Unloading System Definition file...
    • Connection with target Controller has been lost.

    Can you deploy if you only have the two 9401 modules in the chassis (no other modules) and in the sysdef?  I meant to ask if you could attach your system definition file to the forum post so we can see it as well (sorry for the confusion).  
    Are you using any of the specialty configurations for the 9401 modules? (ex: counter, PWM, quadrature, etc)
    You will probably want to post this on the support page for the Scan Engine/EtherCAT Custom Device: https://decibel.ni.com/content/thread/8671  
    Custom devices aren't officially supported by NI, so technical questions and issues are handled on the above page.
    Kevin W.
    Applications Engineer
    National Instruments

  • Cisco AnyConnect VPN won't install, says There is a newer version of the AnyConnect client already installed

    I had an issue with my Cisco Anyconnect VPN not working, so uninstalled it. I've tried a new install and now I get the message "There is a newer version of the AnyConnect client installed" and it won't tell me install it at all. I've gone through various recommendations on the site included this :-
    Go to "Regedit" and search for "Deterministic Networks" and delete it.
    HKEY_LOCAL_MACHINE \SOFTWARE\Deterministic Networks
    Search with the following keywords in the registry, under "Uninstall" or  "Components" folders and delete any related entries.
    Vpnapi
    Vpngui
    Cisco
    CVPND
    CVPNDRA
    Ipsecdialer
    Source: https://supportforums.cisco.com/message/3728011#3728011
    But I've still got the same problem, and just cant find anything to help !

    Disable Internet Connection Sharing (ICS) and then try You can disable ICS in two ways:
    Per Adapter:
    Click the Start button.
    Click on Control Panel.
    Click on View Network Status and Tasks
    Click on Change adapter settings
    Right-click the shared connection and choose Properties
    Click the Sharing tab
    Clear the Allow other network users to connect through this computer's Internet connection checkbox
    Click OK
    System Wide:
    Click the Start button (Windows' orb)
    Type: services.msc and press ENTER
    Double-Click on Internet Connection Sharing (ICS)
    Change Startup Type to Disabled
    Reboot the computer
    You can now try reinstalling the WiscVPN client again

  • How can I ensure newer versions of the same page are opened every time I visit

    I am advised by my Uni IT screen to ensure that firefox is set to check for 'newer versions of the same page with every visit to the page'. This is to ensure proper functioning inside the University's internal tutorial program.

    # Type '''about:config''' into the location bar and press enter
    # Accept the warning message that appears, you will be taken to a list of preferences
    # Locate the preference '''browser.cache.check_doc_frequency''', double-click on it and change its value to '''1'''
    http://kb.mozillazine.org/Browser.cache.check_doc_frequency

  • Can I modify the data type of a dynamic parameter?

    I am using CR2008 against an Oracle 11 db and have a report with dynamic parameters.
    One of the report sources is a custom view that selects all of the possible 'pay ending dates' where one of the fields from this view is used as the source for the dynamic parameter.
    The view performs a TRUNC on the date field in an effort to eliminate the TIME component.
    The problem is that the parameter definintion defaults to DATE/TIME (vs. just DATE). I'm wondering if there is any way to modify the data type of the parameter to be DATE only.
    I've searched several forumns but have not found anything.
    One solution I can think of is to have the custom view format the date field as a VARCHAR (sans the time component) which I assume would force the dynamic parameter data type to string, and then have the report perform a todate function on the value when applying the criteria.
    Anyone else have an idea? Just seems like CR should allow the developer to specify the data type- especially b/w Date and Date/Time, rather than make an assumption.
    Thank you in advance-
    emaher

    emaher,
    Here's what you can do:
    Leave the existing date column as it is in the view...
    Just add another column to the view that casts the the date as a VarChar data type and formats the date as you would like it to be.
    So now you'll have 2 date columns in the view... 1 that's still a date and another that a character string.
    Now for your parameter, use the date version as the parameter value and the text version as the parameter description.
    Be sure to set the "Prompt with description only" is set to true.
    This way the user sees the LoV in the desired format but there's not need to wrangle it back into a date for data selection.
    HTH,
    Jason

  • Issue with the Data Type 'Number' in Business Objects

    Hi,
    I have an Object in the Universe where the Data Type of the Object is a number. This Column pertaining to this Object has certain values in the database out of which there is a 17 Digit Value which is 00000000031101165.
    Now, when trying to retreive the same value through Business Objects it is getting rounded off to 00000000031101200 automatically when trying to view in Webi and when trying to retreive the same in Designer/Deski, it displays as 0.000000003110116E+16.
    So, I would like to know if there is any other alternative in trying to retreive the Original Value that would not round off. Also, do we have any Limitation for the Data Type Number in Business Objects? The Version we are on is XI3.1.
    Note: There are no functions that are used on this Object at the Universe Level and would not like to use any functions here.

    What is the underlying database?
    It looks like the data is considered to have two decimals, but is rounded to zero decimals.
    Only you don't see the number formatting.
    Is this a BW query?
    Is this a calculated keyfigure?
    In the query you can specify the rounding you want and it is also possible to specify it on an infoobject level.
    Check those settings...
    Hope this helps,
    Marianne
    PS. Oh, and about the formatting, you can specify a default object format in the universe and override it on the final client (WebI, Crystal)

  • What is the data type for the Data Dashboard XY Graph?

    Hey all,
    I am playing with the new Data Dashboard (!!) on my iPad 2 and am having trouble setting up the shared variables that host data to the XY Graph.
    On my PC, in my Project (inside of a variable library) I have set up shared variables for all of the other controls/indicators available in the app; They all work great. However, I have not been able to identify the data type that is for the XY Graph in Data Dashboard. Of course, inside LabVIEW, I use a cluster of 2 arrays; this is not an available data type that I can select while creating a new variable on the hosting side. I have even gone so far as to create a custom control from my XYGraph in LabVIEW and then creating the data type "From Custom Control..." with no success.
    What gives? Am I missing something obvious? Thanks for the help!!
    Tom
    Solved!
    Go to Solution.

    Great question, Aerogoob.
    The XY graph can be bound to a 1d array of "points", where each point is a cluster of two numerics (X and Y). To create a shared variable of this type, you can set the data type to "From Custom Control..." in the shared variable properties dialog. Of course, first you'll have to build the custom control of the correct type: array of cluster of two numerics.
    If any of that doesn't make sense, please post back and we can walk you through it in more detail.
    Also, just for completeness, the chart indicator can be bound to a scalar numeric or to an array of numerics. The graph indicator can only be bound to an array of numerics.

  • What's the data type when defining a KF to show an integer with a sign?

    We want show some days difference which should be an integer with either a positive or negative sign.  I used to design a KF with type of Number with "DEC - Counter or amount field with comma and sign" as the Data Type, but find it shows 25.000 if the day difference is 25 days.  We want to show it as 25 other than 25.000.  Then what type would we pick when defining the KF?  Use Integer as the type?  But we also want it to show the sign symbol.
    The type field is dimmed as long as the InfoObj. is activated that I have to remove this field.  I've delete all the data loaded in ODS, PSA and etc., and I have successfully remove this KF from InfoSource, but when I try to remove it from the ODS, always get the msg "Can't move/delete locked InfoObjects" even if the InfoObject is not locked (I've tried SM12 to delete all locked entries and also tried relog on, but not helpful).  If someone gives any idea, I would be very appreciated on how to remove this KF from ODS and also let me what type should I use when creating a new KF which only shows integer with a sign!
    Thanks

    hey Siggi,
    Now after I right click the ODS and select "Delete Data", the KF eventually gets removed from the ODS without any error, then I continue to delete this InfoObj. 
    However, when I run the InfoPackage to load data to the ODS, get a msg (see below in between two dashed lines):
    Syntax error in GP_ERR_RSDRO_UPDATE, row 1,210 (-> long text)
    Message no. RG102
    Diagnosis
    The data object "I_S_OLDDATA" does not have a component called "/BIC/Z_field".
    Where Z_field is the InfoObject we deleted.  With this error, that's even worse since that stops any data coming in!  How to get rid of this error that we can continue to load data?
    Thanks

  • The data type of InfoObject 0ORGUNIT is incompatible with field 0ORGUNIT

    I am trying to create a DataSource in BW to load the organizational hierarchy from HR R/3 to BW.  I get the message "The data type of InfoObject 0ORGUNIT is incompatible with field 0ORGUNIT," 
    Our BW version is 3.5; the version of HR R/3 is SAP ECC 6.0.
    I'm not sure what this message means but if I continue to click OK, I get transfer structures for the org attributes and hierarchies but not the text.  The key to the text is 60 characters.  Shouldn't the key be the org unit, which is in format NUMC 8?
    I was able to create this DataSource last summer, when HR was in a different version (4.6?) with no issues. Does anybody have any idea what's wrong and what I can do about it?
    Thanks!

    Would be nice if you could share the resolution they found,
    since that might help other people as well.
    For instance, me.... as we face exactly the same problem at the moment !!
    Ch

  • What the data type of this variant? (in the following)

    What's the datatype of the following variant (use probe and indicator):
    value -> 1356.00
    I want to tranfer it to numerical data. When I tranfer it using "variant to data" function (the datatype used is string or numerical), An error occured:
     ERROR 91 occured at Variant to Data. The data type is not compatible with the data type wired to the type input."
    Thank you very much!

    You can investigate any Variant by using the 'Variant Probe' for download from LAVA.
    It will tell you what the actual contents of the Variant were.
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

Maybe you are looking for

  • Error while Executing th program

    Hi Guys,              When i am executing my program I am getting this type of error           " Object ZMMOF3007_INVCE_TO_FACILITIES of class RE and language EN does not exist. Message no. SF616"                       can anybody tell me whsts the s

  • Windows 8.1 Update and Verizon

    How long does Microsoft expect us to wait for the update to arrive on the the phones.  It will almost at this point and be a 1/2 a year since the update has been released and yet no update.  how does Microsoft expect to keep up with Apple or Android

  • Problem in converting the date format in Second's place

    I am developing an application using OAF in JDeveloper. I have to pass the current date from my page to a quary to filter the data. I used the following: String PresentDate=this.getOADBTransaction().getCurrentDBDate().toString(); However it is sendin

  • What's new in solaris 8 from solaris 7

    Hi, I want a help regarding the solaris 8 interfaces which are modified from solaris 7. Can some one provide me information regarding these interfaces. Thanks in advance.

  • Old domain controller crashed. Created a new one..having to rejoin computers to domain..easier way to do this?

    I had a single domain controller. It has crashed. I had to create a new domain controller with all the same existing information from the old server..same domain name, server name, and IP. Im having issues with desktops. Everything is setup on the se