ABAP process job ( BI_PROCESS_ABAP ) in process chain running for long time

Dear Experts,
We have an ABAP process job  BI_PROCESS_ABAP  in a process chain. This job is running for a very long time than previous run time.
Recently we had an ORACLE database upgrade from 9.2 to 10g.
From the very next day , we are having this problem.
And also previously this process-chain was under control of BASIS guys . they were using a tool called CRONACLE to schedule it. At the time of upgrade this tool was crashed and they asked us to schedule it in BW system instead.
Underlying program is using two custom tables.
one is having both primary & secondary indexes but the other table is having only primary index.
I am not sure whether we have secondary indexes on other table prior to upgrade or not.
Where must be the problem?...
At the time of upgrade BASIS has re-organized the table space along with database upgrade.
please help me...
Regards,
SRIKANTH

Please ask yr basis consultant to check the system parms.
Below i have listed down SAP recommneded system parms .
abap/heap_area_total 4000000000
abap/heap_area_dia 2000000000
abap/heap_area_nondia 2000000000
Also check in SM37 if any other jobs are running for long time, peventing the your job running.
Check the SM12 for locks or SM58

Similar Messages

  • Report running for long time & performance tuning

    Hi All,
    (1). WebI report is running for long time.so what are the steps i need to check for it ?
    (2). Can you tell me about performance tuning in BO ?
    please help me.....
    Thanks
    Kumar

    (1). WebI report is running for long time.so what are the steps i need to check for it ?
    The first step is to see if the problem lies in the query on the data source or in webi itself. Depending on the data source there are different ways to extract the query and try to run it against the database. Which source does your report uses?
    (2). Can you tell me about performance tuning in BO ?
    I would recommend to start by reading the administrator's guide. There is a section about how to improve performance.
    Regards,
    Stratos

  • Background Jobs running for long time.

    Dear All,
    I had done the Homogeneous System Copy on my ECC 6 QA System successfully by restoring the offline backup of Production system. My system is up & running but  I have some Performace issues in the system. I also observed that some jobs are running since long time & most commonly i got the below line in the BGD Trace "WP has reached abap/heaplimit = 40000000 bytes".
    I search for the notes but couldn't find anything.
    Please help me to resolve this issue.
    Below is the Trace :-
    trc file: "dev_w7", trc level: 1, release: "700"
    ACTIVE TRACE LEVEL           1
    ACTIVE TRACE COMPONENTS      all, MJ
    M sysno      12
    M sid        UBQ
    M systemid   370 (Solaris on SPARCV9 CPU)
    M relno      7000
    M patchlevel 0
    M patchno    52
    M intno      20050900
    M make:      single threaded, Unicode, 64 bit, optimized
    M pid        16335
    M
    M
    M Mon Nov 10 19:01:10 2008
    M  kernel runs with dp version 210000(ext=109000) (@(#) DPLIB-INT-VERSION-210000-UC)
    M  length of sys_adm_ext is 572 bytes
    M  ThInit: running on host UBSQAS
    M  calling db_connect ...
    C  Client NLS settings: AMERICAN_AMERICA.UTF8
    C  Logon as OPS$-user to get SAPSR3's password
    C  Connecting as /@UBQ on connection 0 (nls_hdl 0) ... (dbsl 700 240106)
    C  Nls CharacterSet                 NationalCharSet              C      EnvHp      ErrHp ErrHpBatch
    C    0 UTF8                                                      1 0x1067f1be0 0x1067f96a0 0x106809e38
    C  Attaching to DB Server UBQ (con_hdl=0,svchp=0x106809d68,svrhp=0x10680c0b8)
    C  Starting user session (con_hdl=0,svchp=0x106809d68,srvhp=0x10680c0b8,usrhp=0x1067f9eb8)
    C  Now '/@UBQ' is connected (con_hdl 0, nls_hdl 0).
    C  Got SAPSR3's password from OPS$-user
    C  Disconnecting from connection 0 ...
    C  Closing user session (con_hdl=0,svchp=0x106809d68,usrhp=0x1067f9eb8)
    C  Now I'm disconnected from ORACLE
    C  Connecting as SAPSR3/<pwd>@UBQ on connection 0 (nls_hdl 0) ... (dbsl 700 240106)
    C  Nls CharacterSet                 NationalCharSet              C      EnvHp      ErrHp ErrHpBatch
    C    0 UTF8                                                      1 0x1067f1be0 0x1067f96a0 0x106809e38
    C  Starting user session (con_hdl=0,svchp=0x106809d68,srvhp=0x10680c0b8,usrhp=0x1067f9eb8)
    C  Now 'SAPSR3/<pwd>@UBQ' is connected (con_hdl 0, nls_hdl 0).
    C  Database NLS settings: AMERICAN_AMERICA.UTF8
    C  Database instance UBQ is running on UBSQAS with ORACLE version 10.2.0.2.0 since 20081109
    B  Connection 0 opened (DBSL handle 0)
    B  Wp  Hdl ConName          ConId     ConState     TX  PRM RCT TIM MAX OPT Date     Time   DBHost
    B  000 000 R/3              000000000 ACTIVE       NO  YES NO  000 255 255 20081110 190110 UBSQAS
    M  db_connect o.k.
    M  ICT: exclude compression: .zip,.cs,.rar,.arj,.z,.gz,.tar,.lzh,.cab,.hqx,.ace,.jar,.ear,.war,.css,.pdf,.js,.gzip
    I  MtxInit: 7 0 0
    M  SHM_PRES_BUF###(addr: 0xffffffff6c400000, size: 4400000)
    M  SHM_ROLL_AREA##(addr: 0xfffffffe56000000, size: 134217728)
    M  SHM_PAGING_AREA##(addr: 0xfffffffe50000000, size: 67108864)
    M  SHM_ROLL_ADM###(addr: 0xffffffff7000a000, size: 2672386)
    M  SHM_PAGING_ADM##(addr: 0xffffffff77a00000, size: 656416)
    M  ThCreateNoBuffer##allocated 572152 bytes for 1000 entries at 0xfffffffe48004000
    M  ThCreateNoBuffer##index size: 3000 elems
    M  ThCreateVBAdm##allocated 12176 bytes (50 server) at 0xffffffff77900000
    X  EmInit: MmSetImplementation( 2 ).
    X  MM diagnostic options set: 0
    X  <ES> client 7 initializing ....
    X  Using implementation std
    X  ES initialized.
    B  db_con_shm_ini:  WP_ID = 7, WP_CNT = 12, CON_ID = -1
    B  dbtbxbuf: Buffer TABL  (addr: 0xfffffffe42000100, size: 30000000, end: 0xfffffffe43c9c480)
    B  dbtbxbuf: Buffer TABLP (addr: 0xffffffff6b800100, size: 10240000, end: 0xffffffff6c1c4100)
    B  dbexpbuf: Buffer EIBUF (addr: 0xffffffff65800108, size: 4194304, end: 0xffffffff65c00108)
    B  dbexpbuf: Buffer ESM   (addr: 0xffffffff65000108, size: 4194304, end: 0xffffffff65400108)
    B  dbexpbuf: Buffer CUA   (addr: 0xfffffffe4b01e108, size: 3072000, end: 0xfffffffe4b30c108)
    B  dbexpbuf: Buffer OTR   (addr: 0xffffffff64800108, size: 4194304, end: 0xffffffff64c00108)
    M  rdisp/reinitialize_code_page -> 0
    M  icm/accept_remote_trace_level -> 0
    M  rdisp/no_hooks_for_sqlbreak -> 0
    M  CCMS: AlInitGlobals : alert/use_sema_lock = TRUE.
    S  *** init spool environment
    S  initialize debug system
    T  Stack direction is downwards.
    T  debug control: prepare exclude for printer trace
    T  new memory block 0x106ab5bb0
    S  spool kernel/ddic check: Ok
    S  using table TSP02FX for frontend printing
    S  1 spool work process(es) found
    S  frontend print via spool service enabled
    S  printer list size is 150
    S  printer type list size is 50
    S  queue size (profile)   = 300
    S  hostspool list size = 3000
    S  option list size is 30
    S      found processing queue enabled
    S  found spool memory service RSPO-RCLOCKS at 0xfffffffe4b30e070
    S  doing lock recovery
    S  setting server cache root
    S  found spool memory service RSPO-SERVERCACHE at 0xfffffffe4b30e548
    S    using messages for server info
    S  size of spec char cache entry: 297032 bytes (timeout 100 sec)
    S  size of open spool request entry: 2168 bytes
    S  immediate print option for implicitely closed spool requests is disabled
    A Mon Nov 10 19:01:11 2008
    A
    A     PXA
    A  PXA INITIALIZATION
    A  PXA: Fragment Size too small: 73 MB, reducing # of fragments
    A  System page size: 8kb, total admin_size: 11048kb, dir_size: 10992kb.
    A  Attached to PXA (address 0xfffffffe20000000, size 300000K)
    A  abap/pxa = shared protect gen_remote
    A  PXA INITIALIZATION FINISHED
    A     PXA
    A
    A  ABAP ShmAdm attached (addr=0xfffffffe60590000 leng=20938752 end=0xfffffffe61988000)
    A  >> Shm MMADM area (addr=0xfffffffe6083edd0 leng=140480 end=0xfffffffe60861290)
    A  >> Shm MMDAT area (addr=0xfffffffe60862000 leng=17981440 end=0xfffffffe61988000)
    A  RFC rfc/signon_error_log = -1
    A  RFC rfc/dump_connection_info = 0
    A  RFC rfc/dump_client_info = 0
    A  RFC rfc/cp_convert/ignore_error = 1
    A  RFC rfc/cp_convert/conversion_char = 23
    A  RFC rfc/wan_compress/threshold = 251
    A  RFC rfc/recorder_pcs not set, use defaule value: 2
    A  RFC rfc/delta_trc_level not set, use default value: 0
    A  RFC rfc/no_uuid_check not set, use default value: 0
    A  RFC rfc/bc_ignore_thcmaccp_retcode not set, use default value: 0
    A  RFC Method> initialize RemObjDriver for ABAP Objects
    M  ThrCreateShObjects##allocated 12676 bytes at 0xffffffff77700000
    N  SsfSapSecin: putenv(SECUDIR=/usr/sap/UBQ/DVEBMGS12/sec): ok
    N
    N  =================================================
    N  === SSF INITIALIZATION:
    N  ===...SSF Security Toolkit name SAPSECULIB .
    N  ===...SSF trace level is 0 .
    N  ===...SSF library is /usr/sap/UBQ/DVEBMGS12/exe/libsapsecu.so .
    N  ===...SSF hash algorithm is SHA1 .
    N  ===...SSF symmetric encryption algorithm is DES-CBC .
    N  ===...sucessfully completed.
    N  =================================================
    N  =================================================
    N  MskiInitLogonTicketCacheHandle: Logon Ticket cache pointer retrieved from shared memory.
    N  MskiInitLogonTicketCacheHandle: Workprocess runs with Logon Ticket cache.
    M  JrfcVmcRegisterNativesDriver o.k.
    W  =================================================
    W  === ipl_Init() called
    W    ipl_Init(): wp task type is 4:BTC, skip initialization
    W  === ipl_Init() returns 0, ITSPE_OK: OK
    W  =================================================
    E  Replication is disabled
    E  EnqCcInitialize: local lock table initialization o.k.
    E  EnqId_SuppressIpc: local EnqId initialization o.k.
    E  EnqCcInitialize: local enqueue client init o.k.
    B
    B Mon Nov 10 19:30:28 2008
    B  dbtran INFO (init_connection '<DEFAULT>' [ORACLE:700.08]):
    B   max_blocking_factor =  15,  max_in_blocking_factor      =   5,
    B   min_blocking_factor =  10,  min_in_blocking_factor      =   5,
    B   prefer_union_all    =   0,  prefer_join                 =   0,
    B   prefer_fix_blocking =   0,  prefer_in_itab_opt          =   1,
    B   convert AVG         =   0,  alias table FUPD            =   0,
    B   escape_as_literal   =   1,  opt GE LE to BETWEEN        =   0,
    B   select *            =0x0f,  character encoding          = STD / <none>:-,
    B   use_hints           = abap->1, dbif->0x1, upto->2147483647, rule_in->0,
    B                         rule_fae->0, concat_fae->0, concat_fae_or->0
    M  SecAudit(RsauShmInit): WP attached to existing shared memory.
    M  SecAudit(RsauShmInit): addr of SCSA........... = 0xffffffff78500000
    M  SecAudit(RsauShmInit): addr of RSAUSHM........ = 0xffffffff78500768
    M  SecAudit(RsauShmInit): addr of RSAUSLOTINFO... = 0xffffffff785007a0
    M  SecAudit(RsauShmInit): addr of RSAUSLOTS...... = 0xffffffff785007ac
    A
    A Mon Nov 10 20:04:25 2008
    A  WP has reached abap/heaplimit = 40000000 bytes
    A
    A Tue Nov 11 02:25:41 2008
    A  generated report /1BCWDY/BSAEKROD3IX58HSBOTLJ==CP         with fingerprint 1078C98BF377F2618A7F4843DE257FC8   50556
    Tue Nov 11 02:36:40 2008
    actual OCI-type (1) of OUT-variable 0 differs from cached statement (96) ==> reparsing
    sc_p=0x10673a550,no=176,idc_p=0x106750c68,con=0,act=1,slen=149,smax=768,#vars=5,stmt=0x107ba9dc0,table=TADIR
    prep=1,lit=0,nsql=0,lobret=0,#exec=455,dbcnt=0,upsh_p=(nil),ocistmth_p=0x1073f3ec0
    IN : cols=5,rmax=1,xcnt=0,rpc=0,rowi=0,rtot=0,upto=4294967295,rsize=108,vmax=32,bound=1,iobuf_p=0x1068680e0,vda_p=0x1073f8960
          lobs=0,lmax=0,lpcnt=0,larr=(nil),lcurr_p=(nil),rret=0
    OUT: cols=1,rmax=0,xcnt=0,rpc=0,rowi=0,rtot=0,upto=1,rsize=0,vmax=32,bound=1,iobuf_p=(nil),vda_p=0x1073f90f0
          lobs=0,lmax=0,lpcnt=0,larr=(nil),lcurr_p=(nil),rret=0
    SELECT /*+ FIRST_ROWS  */ "OBJ_NAME" FROM "TADIR" WHERE "PGMID" = :A0 AND ( "OBJECT" = :A1 OR "OBJEC\
    T" = :A2 ) AND "OBJ_NAME" = :A3 AND ROWNUM <= :A4;
    actual OCI-type (96) of OUT-variable 0 differs from cached statement (1) ==> reparsing
    sc_p=0x10673a550,no=176,idc_p=0x106750c68,con=0,act=1,slen=149,smax=768,#vars=5,stmt=0x107ba9dc0,table=TADIR
    prep=1,lit=0,nsql=0,lobret=0,#exec=2,dbcnt=0,upsh_p=(nil),ocistmth_p=0x1073f3ec0
    IN : cols=5,rmax=1,xcnt=0,rpc=0,rowi=0,rtot=0,upto=4294967295,rsize=108,vmax=32,bound=1,iobuf_p=0x1068680e0,vda_p=0x1073f8960
          lobs=0,lmax=0,lpcnt=0,larr=(nil),lcurr_p=(nil),rret=0
    OUT: cols=1,rmax=0,xcnt=0,rpc=0,rowi=0,rtot=0,upto=1,rsize=0,vmax=32,bound=1,iobuf_p=(nil),vda_p=0x1073f90f0
          lobs=0,lmax=0,lpcnt=0,larr=(nil),lcurr_p=(nil),rret=0
    SELECT /*+ FIRST_ROWS  */ "OBJ_NAME" FROM "TADIR" WHERE "PGMID" = :A0 AND ( "OBJECT" = :A1 OR "OBJEC\
    T" = :A2 ) AND "OBJ_NAME" = :A3 AND ROWNUM <= :A4;
    Tue Nov 11 02:36:42 2008
    actual OCI-type (1) of OUT-variable 0 differs from cached statement (96) ==> reparsing
    sc_p=0x10673a550,no=176,idc_p=0x106750c68,con=0,act=1,slen=149,smax=768,#vars=5,stmt=0x107ba9dc0,table=TADIR
    prep=1,lit=0,nsql=0,lobret=0,#exec=3,dbcnt=0,upsh_p=(nil),ocistmth_p=0x1073f3ec0
    IN : cols=5,rmax=1,xcnt=0,rpc=0,rowi=0,rtot=0,upto=4294967295,rsize=108,vmax=32,bound=1,iobuf_p=0x1068680e0,vda_p=0x1073f8960
          lobs=0,lmax=0,lpcnt=0,larr=(nil),lcurr_p=(nil),rret=0
    OUT: cols=1,rmax=0,xcnt=0,rpc=0,rowi=0,rtot=0,upto=1,rsize=0,vmax=32,bound=1,iobuf_p=(nil),vda_p=0x1073f90f0
          lobs=0,lmax=0,lpcnt=0,larr=(nil),lcurr_p=(nil),rret=0
    SELECT /*+ FIRST_ROWS  */ "OBJ_NAME" FROM "TADIR" WHERE "PGMID" = :A0 AND ( "OBJECT" = :A1 OR "OBJEC\
    T" = :A2 ) AND "OBJ_NAME" = :A3 AND ROWNUM <= :A4;
    Thanks,
    Shambo

    Hi Shambo
    have you checked the oracle parameters as per the sap note 830576,and also the backup which you have taken is a logical backup,in that case you have to run the update database statistics either from DB13 or BRTOOLS
    also check ST04 and also ST02 to do a  performance tuning
    I believe its more Database Parameter issue
    regards
    George Varghese

  • ECC6 upgrade phase XPRAS_UPG running for long time

    Hi,
    I am performing a Downtime minimized upgrade (MODPROF_TRANS) from R34.7ext2 to ECC6.0 / Windows2003/MSSQL2005
    Currently i am in the phase XPRAS_UPG .It is running for really long time.I tried to reset the phase but still went on for more than 10 hrs. I initialized the phase now its running for more than 7 hours. There are no processes when i check in SM50 and no log files updated. There is no log file called XPRAS_UPG.ELG.SM37 no jobs running.
    Though if it takes long time , How do i confirm that my upgrade phase is running ??????????as its not updating anything
    In PARDIST_SHD phase when there was en error , i have manuall deleted the DB trigger acording to the note 956198. And the phase went on.
    Now after reading few messages reg this error , i checked DB02 but no locks on any table . Have cheked note 558197,1292069,1142410,1138351,1062559,597885,551298. But nothings applicable in my case.
    Please suggest ...
    will really appreciate your help.
    Chandra

    Dear Chandra,
    Regarding long runtime for XPRAS phase kindly note the following:
    1. The reason of slow performance of XPRAS phase can vary differently.
    Basically during XPRAS phase, there're a lot of reports to run. These
    reports are inlcuded in the transport requests(both upgrade
    requests and support packages). If there's a performance problem,
    it very likely the database performance problem, such as wrong
    access plan was chosen, or missing index, etc.
    2. To find out the performance problems in the XPRAS, you can always
    logon into the system. During the XPRAS phase, the system has to be up and running.
    In SM50, usually you can find which report is running, and/or which table is being accessed.
    If you find some table accesses take unusually long time, please
    record the table name and find the SQL statement. Sometimes a simple
    index can solve the problem, sometimes you need help from Oracle
    to get the solution.
    3. If you want to shorten the downtime, you can select less support
    packages since all SPs have a lot of reports to run in XPRAS. But
    remember you need to import them soon or later. But if you prefer
    import them later it's fine.
    Currently if you check in SM37 then you can see RDDEXECL job in active status.
    Check for the job log, if there are any errors reported?
    Thereafter check the SM50 and see if its taking unusually long time for some particular table.
    If so then it might be because you might have not updated the statistics for that particular table.
    Also check what was the parameter value of Number of batch processes defined by you
    for upgrade. If you have defined very less number of batch processes for upgrade then also
    it will take more time.
    Check accordingly and let me know for further help.
    Regards,
    Abhishek
    Edited by: Abhishek Srivastava on May 9, 2010 10:57 AM

  • Loud fan runs for long time then overheating then shutdown

    About 2 months ago I started to have problems with my MacBook. It is my main machine so this is something I really want to get fixed. The new behavior: fan(s) run loud for some time, then the computer refuses to accept a charge, and then it shuts down. It seems to do this when it feels like it. It did not do this before. I have Apple Care and took it to the Genius Bar. But they said it passed all their hardware tests. I just don't see how it could be anything else but a hardware problem. What should I do?

    It could be that you have some errant process running sometimes but not all the time, due to who-knows-what reason (to be discovered later if this bears out.
    Have you ran Activity Monitor when it is running hot to see if there is something taking up more than a few percent of CPU time?
    I don't know the likelyhood of this next idea because I have not yet had a MacBook apart but all modern computers have some kind of heat sink on the CPU and it may be that that heat sink is sometimes not making a good physical contact to the CPU chip. This has been the case on some Mac powerbooks in the past.

  • Full GC running for longer time

    hi Team,
    We are running SLD on separate hardware with Windows 2003. But since couple of months we been observing that 'full GC taking longer time' then it used to be. So wondering what are the possible parameters, configuration items that i need to look back to find tune this issue.
    any good reference docs related to find tuning the GC is much appriciated.
    Thanks
    Sekhar

    I have three basic suggestions.
    1.  Decrease your heap size.  This will make the GC shorter but more frequent.
    2.  Increase the heap size to some huge number.  This will make it take longer but run infrequently.
    3.  Use the java option to never do GC on the java startup and then force GC on a daily basis when the system is relatively unused.  This also requires increasing the heap size.  You may need to have a developer write something to force GC.  In smaller companies, you can just restart J2ee each night but that seems like cheating.
    hth

  • Cannot use Dreamweaver CS6 because of "running for long time" script issue

    Started getting this error yesterday, it’s killing me....
    Dialog box says: "A script in file ~:Applications:ADOBE CS6:Adobe Dreamweaver CS6:Configuration:Shared:BC:JS:bc_sites.js has been running for a long time.  Do you want to continue?"
    The message keeps persisting almost everytime I try to edit something, the Yes or No options don’t seem to do anythin other than remove the dialogue box temporarily.
    Searched for a solution to this but only found unanswered questions, so I uninstalled the app, re-installed it and all seemed to be ok for a short while and now the issue is back.
    I’m using business catalyst and like the improved imtegration, but this is broken!!
    Please Help..

    designchiefkm wrote:
    Hi, yeah that link leads to "Ask the experts" which is this community forum...
    very bland support me thinks...
    I'm a strong supporter of DW and Adobe, but it's one of the reasons I'm not in the Cloud or using BC.  Support is charged at a per-incident or corporate rate: http://www.adobe.com/support/programs/ . 
    You can try trashing that Configuration folder ( http://helpx.adobe.com/dreamweaver/kb/troubleshoot-javascript-errors-dreamweaver-cs4.html - See steps 12 & 4 for details).  But that's about the extent of community support here for most technical issues.  Seeing as how you have only 3 posts since April  you probably were not around the last time customers spoke up and complained and prompted the Lambert Walsh letter almost 3 years back now. ( http://blogs.adobe.com/captivate/2009/08/open_letter_to_our_customers_o.html ).  Just don't be afraid to speak up or write to Adobe, they will listen.

  • Report running for longer time

    Hi,
    I have a report in dashboard which does not stop running and the clock on it keeps on ticking.
    Please suggest what must be the possible reasons that this report is taking so much time to run . So I that I can backtrack it.
    Thanks.

    949675 wrote:
    Hi,
    I have a report in dashboard which does not stop running and the clock on it keeps on ticking.
    Please suggest what must be the possible reasons that this report is taking so much time to run . So I that I can backtrack it.
    Thanks.Check out this presentation to improve the performance on the report: http://www.peakindicators.com/media_pi/Knowledge/obiee%20and%20database%20performance%20tuning.pdf

  • How to stop process chain if it yellow for long time

    hello all,
    I see that my process chain is running for long time and is yellow for more than last 24 hours now. I can see where the chain is stuck(not going ahead).
    What do we normally do in such scenarios?
    Also one more question I have is about delete PSA request process variant. Can i use the same variant in two different process chains, is yes than do I have to include the name of the PSA tables that are in both the process chains. When the variant runs in 1st chain does it delete the PSA tables from the second chain as well..(i hope i made this clear)
    Thanks in advance

    Once you have done with your init load manually. Then in case it was just the start of the process in ur Process Chain then first remove the chain from schedule and then go to the start process of the process chain and save the setting for immediate, uncheck the periodic box and save and then come out of the screen and then execute and activate the chain.
    Note:
    1. Before changing the setting in the start process make a note of the start time and also its periodic value.
    2. Once the chain is completed then change the setting in the start process back to previous start time and periodic value.
    3. Don’t forget to save and activate the chain.
    Regards,
    Rohini

  • Background job is running for long tome in source system (ECC)

    Hi All,
    Background job is running for long tome in source system (ECC) while extracting data to PSA.
    I checked in ECC system SM66,SM50 the job is still running
    in SM37 the job is Active
    There are only maximum 7000 records the extractor is 2LIS_02_ITM but it is taking 11 to 13 hours to load to PSA daily
    I had checked enhancements every thing is correct.
    Please help me on this how can I solve this issue.
    Regards
    Supraja K

    Hi sudhi,
    The difference between Call customer enhancement...  and  Result of customer enhancement:... is very less we can say this as a second.
    The difference is between LUWs confirmed and 1 LUWs -
       and Call customer enhancement -
    Please find the job log details below, and give me the solution to ressolve this
    01:06:43 ***01:06:43 * ztta/roll_extension........... 2000000000                              *                 R8           050
                     R8           048
    01:06:43 1 LUWs confirmed and 1 LUWs to be deleted with function module RSC2_QOUT_CONFIRM_DATA     RSQU          036
    06:56:31 Call customer enhancement BW_BTE_CALL_BW204010_E (BTE) with 5.208 records                  R3           407
    06:56:31 Result of customer enhancement: 5.208 records                                              R3           408
    06:56:31 Call customer enhancement EXIT_SAPLRSAP_001 (CMOD) with 5.208 records                      R3           407
    06:56:31 Result of customer enhancement: 5.208 records                                              R3           408
    06:56:31 PSA=1 USING SMQS SCHEDULER / IF [tRFC=ON] STARTING qRFC ELSE STARTING SAPI                 R3           299
    06:56:31 Synchronous send of data package 1 (0 parallel tasks)                                      R3           410
    06:56:32 tRFC: Data Package = 0, TID = , Duration = 00:00:00, ARFCSTATE =                           R3           038
    06:56:32 tRFC: Start = 00.00.0000 00:00:00, End = 00.00.0000 00:00:00                               R3           039
    06:56:32 Synchronized transmission of info IDoc 3 (0 parallel tasks)                                R3           414
    06:56:32 IDOC: Info IDoc 3, IDoc No. 1549822, Duration 00:00:00                                     R3           088
    06:56:32 IDoc: Start = 04.10.2011 06:56:32, End = 04.10.2011 06:56:32                               R3           089
    06:56:32 Altogether, 0 records were filtered out through selection conditions                      RSQU          037
    06:56:32 Synchronized transmission of info IDoc 4 (0 parallel tasks)                                R3           414
    06:56:32 IDOC: Info IDoc 4, IDoc No. 1549823, Duration 00:00:00                                     R3           088
    06:56:32 IDoc: Start = 04.10.2011 06:56:32, End = 04.10.2011 06:56:32                               R3           089
    06:56:32 Job finished                                                                               00           517
    Regards
    Supraja

  • F110S (payment run + DME creation) running for infinite time

    Hi ABAP gurus,
    I originally posted this question in ERP finicials but didn't get any response. If somebody has faced any similar issue please share the solution
    A batch job schduled for "daily payment run + creation of DME files" using F110S (SAP ECC 6.0) . The batch is running in production for more infinite time.
    The job runs in following 2 steps
    1. SAPF110S which processes the payment clears FBL5N.
    2. SAPFPAYM_SCHEDULE.
    The second step seems a non-ending process.
    The job variant has only 15 customers, only one invoice is to be processed against one account.
    However in quality system the same job with more than 10,000 customer account range with more than 10 invoices runs just in few minutes.
    Any idea or suggestion why it's taking so long in production? Any missing configuration in production server?
    ==================
    It's not performance issue. When we run F110S or F110 in production with individual login id, program runs the way it should and finishes in reasonable time (for example the scenario I described in question finsihes in few seconds).
    The problem occurs only when production batch job runs with job scheduler; program seems looping somewhere for infinite time - to be particular it keeps reading the table TPRI_DEF which has just few records (must be reading this table inside a loop).
    Thanks,
    Satyaki.

    Hello,
    Since the issue seems still open, (status Not Answered), and since I encountered the same problem, here is the solution. Apparently, a printer must be defined either in OBPM4 (payment variant) or in user personal data (Menu System / User profil / Own data)
    In Box 'Spool Control' / Filed 'OutputDevice', enter your default printer.
    Once SAP report can determine Printer, program will stop to run endless.
    Best regards
    LB

  • Calc scripts running very Long time

    Hi All,
    Recently, i am migrated the objects from Production to Test region. We have 5 applications and each of the application has a set of calc scripts.
    In test region, they are running really long time. Where as in Production, they run for less time.
    In TEST region each Calc script is taking 10 times more time than the Production times.
    No Dimension added or no script is updated. No difference in objects between TEST and PROD.
    Please suggest me, why is this difference.
    Thanks
    Mahesh

    The obvious first question would be if the hardware is different. You would expect prod to be a more powerful server and therefore perform better.I'm seeing a lot of virtualized test servers (who knows, really, what power the box has) and real prod servers. That can make a huge difference in performance.
    It makes benchmarking tough -- yes, you can see how long something will take relative to another process, but there isn't any way to know how it will perform in production until you sneak it over there and benchmark it. It can be a real PITA for Planning.
    And yes, the theory is that dev and prod are similar so that the above isn't an issue, but that seems to be a more theoretical than actual kind of thing.
    Regards,
    Cameron Lackpour

  • Program Running from Long Time

    Hi Friends,
    There is a program running from long time. Can anybody let me know how can i analyse this program other than SM50, SM51, SM66. Its a CRM Program.....there are no logs.......
    Points will be rewarded....
    Thanks,
    Nagesh.

    Hi,
    I will suggest you to check a few places where you can see the status
    1) SM37 job log. If its active make sure that the job log is getting updated at frequent intervals.
    2) Get the job details (server name PID etc from SM37) and see in SM66 if the job is running or not. See if its accessing/updating some tables or is not doing anything at all.
    If its running and if you are able to see it active in SM66 you can wait for some time to let it finish.
    3) You can also try SM50 / SM51 to see what is happening in the system level like reading/inserting tables etc.
    If you feel its active and running you can verify by checking if the number of records getting updated/ inserted /deleted in table level.
    You can take the help of Basis/DB2 to find out what is actually happening in the background.
    This is the best way to identify of something is happening in the database level.
    Thanks,
    JituK

  • The status of importing TR is still running a long time

    Hi,
    I'm facing a problem. the status of importing TR is still running a long time(more than 1 day).
    I think the TR has a problem, How can I know what had happened?
    Which T-code can I get more informations for that?
    jk

    what u are transporting ? do u have any table entries in that ?.....or any standard dev.packages ?
    regards
    Prabhu

  • MSCOBJCL.sql runs for long while applying patch 6678700 for 12.1.1 upgrade

    DB:11.2.0.3.0
    OS: IBM AIX Power system 64 bits 6.1
    Hi All,
    MSCOBJCL.sql runs for long while applying patch 6678700 for 12.1.1 upgrade. We are upgrading from 11.5.10.2.0 to 12.1.1
    Could anyone please share why the script takes so much of time to run?
    Thanks for your time
    Regards,a1_win

    As per Mscobjcl.Sql Is Running Long While Applying Patch.8671960 (Doc ID 1295881.1)
    The patch is already applied in the instance
    BUG_NUMBER CREATION_DATE
    8671960 19-SEP-10
    Thanks,
    a1_win

Maybe you are looking for

  • Bug in new Arch 2008.04-RC?

    I just burned the new Arch AMD64 2008.04-RC to a CD and gave it a go on my Mac Pro. It runs and boots!!  Quite an accomplishment since most Linux LiveCD's (including old versions of Arch) do NOT boot properly on my Mac Pro Tower.  It usually hangs wi

  • Nas 200 connection - pingable, but not accessable

    bringing this issue to life again.... http://homecommunity.cisco.com/t5/Network-Storage/NAS-200/m-p/351520/highlight/true#M7549 My nas 200 seems to lose the authentication and web service every once in a while.  I can still ping the device and get a

  • Incorrect results for calculation based on diff dimensions - 11.1.1.5

    Hello All, OBIEE gives incorrect results when i try to perform a calculation (for eg: addition) based on 2 measures. For eg: (Note: "->" signifies 1:M) Rpd (Physical model & BMM): dim_fe -> dim_gl-> Fact_Legder <- Dim_param Fact_Ledger (agg measures)

  • PI Proxy runtime RFCSYSTEM

    Hi Every one, when i try to active Proxy runtime RFCsystem on runtime workbench i am not able to activate it. i here by enclosing the with following error, Kindly do the needful ASAP An error occurred: Message: Exception in Method: CentralTrexManager

  • How buy at att on line or store?

    if i will buy some iphones at store or online.. they forced me to make a contract ? i need some for gift... but i buy 2 before to apple store with my card... att can sold if you buy before ??