Aironet 1240AG - cant use the web interface

I am trying to configure a new Aironet 1240AG. After it picked an ip address from the DHCP in my lan, I still can't log in using the web interface. I am using an Internet Explorer 6.0 on Win 2000. It keeps telling me cannot find server. please i need assistance

Hi Obinna,
Sorry about the link :( The problem here is the fact that 12.3.(11)JX is a Lightweight image. Have a look;
Warning: All Cisco Aironet Access Points receiving Cisco IOS Software Release 12.3(11)JX will only function in conjunction with a Cisco Wireless LAN Controller. They will no longer be able to function as Cisco Aironet Autonomous Access Points.
This product bulletin describes the content and delivery information for Cisco IOS Software Release 12.3(11)JX. This is a Cisco Lightweight Access Point Protocol (LWAPP) upgrade and recovery support software image supporting Cisco Aironet 1100, Aironet 1130, Aironet 1200, Aironet 1230 AG, Aironet 1240 AG, and Aironet 1300 Series Access Points.
http://www.cisco.com/en/US/products/ps5861/prod_bulletin0900aecd804b1a72.html
You can use this method to convert the AP back to Autonomous Mode (and access via Web);
Reverting the Access Point Back to Autonomous Mode
http://www.cisco.com/en/US/products/hw/wireless/ps430/prod_technical_reference09186a00804fc3dc.html#wp161272
You can convert an access point from lightweight mode back to autonomous mode by loading a Cisco IOS Release that supports autonomous mode (Cisco IOS release 12.3(7)JA or earlier). If the access point is associated to a controller, you can use the controller to load the Cisco IOS release. If the access point is not associated to a controller, you can load the Cisco IOS release using TFTP.
Using a TFTP Server to Return to a Previous Release
Follow these steps to revert from LWAPP mode to autonomous mode by loading a Cisco IOS release using a TFTP server:
Step 1 The static IP address of the PC on which your TFTP server software runs should be between 10.0.0.2 and 10.0.0.30.
Step 2 Make sure that the PC contains the access point image file (such as c1200-k9w7-tar.122-15.JA.tar for a 1200 series access point) in the TFTP server folder and that the TFTP server is activated.
Step 3 Rename the access point image file in the TFTP server folder to c1200-k9w7-tar.default for a 1200 series access point, c1130-k9w7-tar.default for an 1130 series access point, and c1240-k9w7-tar.default for a 1240 series access point.
Step 4 Connect the PC to the access point using a Category 5 (CAT5) Ethernet cable.
Step 5 Disconnect power from the access point.
Step 6 Press and hold MODE while you reconnect power to the access point.
Step 7 Hold the MODE button until the status LED turns red (approximately 20 to 30 seconds) and then release.
Step 8 Wait until the access point reboots, as indicated by all LEDs turning green followed by the Status LED blinking green.
Step 9 After the access point reboots, reconfigure it using the GUI or the CLI.
From this doc;
http://www.cisco.com/en/US/products/hw/wireless/ps430/prod_technical_reference09186a00804fc3dc.html#wp161272
Hope this helps!
Rob

Similar Messages

  • HT4623 i cant use the web on my iphone 3 that iv just bought pre owned it hasnt got software up daate in the general settings

    i am unable to access the web on a pre owned iphone 3 that iv just bought how do i do so??

    Read this: iOS 4: Updating your device to iOS 5 or later
    ... oh I think it is a 3gs or a 3
    This makes a difference. What does it say in Settings > General > About?

  • 500 internal server error when using the web interface

    I've created several tables in Visual Studio, and I'm using a .NET backend for my mobile services.
    The table code looks something like this...
    using Microsoft.WindowsAzure.Mobile.Service;
    namespace AzureService.DataObjects
    public class Country : EntityData
    public string Name { get; set; }
    I then added a scaffolded item to generate the controller for my table, then published.
    I then went to my azure service, flipthechipservice.azure-mobile.net, and tried to run the default POST with default data.
    I then get back a popup, which looks like the following...
    Now what baffles me is I have already created another table, called 'Call', which has exactly the same 'Name' field as the above Country table, yet the Call POSTs work.
    I then tried creating another table, with a Name field, and I get the 500 error again. 
    How can this be possibly happening? Nothing is different, and now I get 500 errors? 
    This makes no sense.
    Thanks

    Thank you, I looked at the logs, and this is the error...
    System.NotSupportedException: Model compatibility cannot be checked because the database does not contain model metadata. Model compatibility can only be checked for databases created using Code First or Code First Migrations.
     at System.Data.Entity.Internal.ModelCompatibilityChecker.CompatibleWithMode
    I looked this error up, and tried
    this proposed solution on StackOverFlow
    I changed the line of code in my WebApiConfig Register() method from...
    Database.SetInitializer(new MobileServiceInitializer());
    to 
    Database.SetInitializer<MobileServiceContext>(new DropCreateDatabaseIfModelChanges<MobileServiceContext>());
    I also have this in my WebApiConfig...
    public class MobileServiceInitializer : DropCreateDatabaseIfModelChanges<MobileServiceContext>
    protected override void Seed(MobileServiceContext context)
    base.Seed(context);
    My understanding is that the database should drop and create if the model changes? So why is this not happening?
    I then tried another solution, and changed DropCreateDatabaseIfModelChanges to DropCreateDatabaseAlways. I still get an internal error. Then the logs show this problem...
    System.Data.SqlClient.SqlException (0x80131904): Cannot open database "master" requested by the login. The login failed.
     Login failed for user 'QEOzFqAnDXLogin_flipthechipservice'.
     This session has been assigned a tracing ID of 'a3b12e78-90f2-4db0-a5ca-6895eebd246c'. Provide this tracing ID to customer support when you need assistance.
     at System.Data.SqlClient.SqlInternalConnection.OnError
    As an additional question, how do I re-generate my local SQL database when debugging on my local PC's web browser? I deleted the database, but can't seem to get it back?
    Thanks

  • How to configure the web interface of service desk

    Hi All,
    We are currently doing a configuration on solman service desk. I am on a stage where in i need to use the web interface of service desk via tcode notif_create_bsp. However, every time i call the transaction code (call the url) i cant view the web. Only an error the "Network Access Message: The website cannot be found".
    I already activate needed services and already publish
    SIAC_PUBLISH_ALL_INT but it still doesnt work.
    I might have missed some configs/procedure on how to do it correctly.
    My questions are.
    1. How am i going to know the qualified domain name
    of the Web AS for solman? How to configure it?
    2. Can anyone give me some guide and any step by step documentation/procedure on this.
    You help/suggestion will be very much appreciated
    Thank you very much,
    Ice

    Hi,
    +"Check the following 2 things. See if the port 8000 is open and in the url for the BSP in internet explorer, replace the host name with the IP address of your Solman server.+
    +"+
    That was a helpful tip. I change the host name with the ip address ofour solman server. However, upon login, it promts me to enter username and password. I've tried to login using my solman password but it shows an error like this.
    Business Server Page (BSP) error
    What happened?
    Calling the BSP page was terminated due to an error.
    SAP Note
    The following error text was processed in the system:
    Die URL enthält keine vollständige Domainangabe (10.123.161.125 statt 10.123.161.125.).
    Exception Class CX_FQDN
    Error Name 
    Program CX_FQDN=======================CP
    Include CX_FQDN=======================CM002
    ABAP Class CX_FQDN
    Method CHECK
    Line 10 
    Long text -
    Error type: Exception
    Your SAP Business Server Pages Team
    Is there anything i need to configure so that i can maintan the username and password?
    Thank you for your assistance,
    Ice

  • How to insert the logo of my company in the web interface page

    Hi Experts,
    I have created one web interface using the web interface wizard. I have to show logo of my company in the page created by web interface wizard. I think I can do so by creating one sub compnent called 'Text, Image, HTML'. Here I can change the property of text. I can click on property of text and then select 'Edit long text' option.
    Then I can insert the HTML code. The HTML code can call the image.
    I am not sure from where the HTML page will call the logo of my company. I think logo should be stored in the server or any other place.
    Can you please let me know how to sort out the issue.
    Thanks

    Hi Raja,
    The link mentioned above is not working. Can you please let me know the solution. I have done following to get the result:
    1) Have uploaded the image in MIMEs at following location. The .jpg is located at following place in SE80:
    $TMP project1 --> BSP Library --> BSP Application --> ZIO_MY_WEB_INTERFACE --> MIMEs --> myimage.jpg
    2) I have created one subcomponent 'Text, Image, HTML'.
    3) I have set the property HTML of this subcomponent as 'true'.
    4) I have set property 'Text' as follows.
    Clicked on value of attribute field of 'Text'. Here I have selected Edit long text. Here I have done HTML coding. Can you please let me know what should be the path of image file here:
    <html>
    <html>
    <p>
    <img src="c:\image002.jpg">
    </p>
    </html>
    </html>
    I think path should be some thing like as follows:
    img src="??"
    I want to know what will be value for ??
    Thanks

  • How to view the Planning area, folders, pmr group used in web interface?

    Hi Gd Morning,
    I am new to web interface in SAP bw 3.5 BPS- web interface. I can see a couple of Web interface developed i want analyze one of them how do i see what is the planning area, parameter group they are selected in the web interface.
    Thanks
    Pooja

    Hi all,
    When u right click on the container or any of the objects there in you can see the properties which describes about the planning area, planning package, parameter group been used.
    Thanks
    Pooja

  • Ive downloaded ff4 now i cant scroll the web pages using my mouse i have to use the scroll bar why's this and can it be sorted?

    i cant use the scroll function on my laptop mouse pad after i downloaded ff4. i have to use the scroll bar on the page its self

    Have you looked for the file in the location as suggested by the post above mine in the linked thread?
    C:\Windows\System32\tp4table.dat
    Or, if you have a Synaptics device, the file might be located in its installation folder, e.g:
    C:\Program Files\Synaptics\SynTP\tp4table.dat
    If/when you find it I think the syntax should be the same. Either way; you could just change it back if something goes wrong and knowing the file name/location will let you search the internet more effectivly as this is a likely cause.

  • Executing the planning function while opening the web interface

    hello all,
    I have created a planning area based on multiprovider.This multiprovider is based on two transactional cube ie,COPA cube and Cost Center cube.
    This planning area is meant for enabling integrated planning.One plans in COPA cube and other plans in Cost Center cube the income statement gets planned based on this two.
    I selected planning items in multiprovider layout to display the income statement.The layout is as follows:
    <b>PlanningItem</b>  <b>Amount</b>
    Net Sales<b>:</b>    9.000,00 INR   (This comes from COPA)
    Sales Overheads<b>:</b> 200,00 INR  (This comes from Cost Center)
    Depreciation<b>:</b> 200,00 INR (This comes from Cost Center)
    Other Expenses<b>:</b> 300,00 INR  (This comes from Cost Center)
    EBIT<b>:</b> 0,00 INR
    Interest Income<b>:</b> 0,00 INR
    Interest Expense<b>:</b> 0,00 INR
    Operating Income<b>:</b> 0,00 INR
    Taxes<b>:</b> 0,00 INR
    Now EBIT planning item is to be calculated from the planning items as follows:
    EBIT = Net Sales-Sales Overheads-Depriciation-Other Expenses
    For this i have created a planning function which calculates EBIT.This function works properly,there are no issues in it.
    My problem is that i want this function to be executed as soon as i open the web interface for my planning application and the result should be as follows:
    <b>PlanningItem</b>  <b>Amount</b>
    Net Sales<b>:</b>    9.000,00 INR   (This comes from COPA)
    Sales Overheads<b>:</b> 200,00 INR  (This comes from Cost Center)
    Depreciation<b>:</b> 200,00 INR (This comes from Cost Center)
    Other Expenses<b>:</b> 300,00 INR  (This comes from Cost Center)
    EBIT<b>:</b> 8.300,00 INR
    Interest Income<b>:</b> 0,00 INR
    Interest Expense<b>:</b> 0,00 INR
    Operating Income<b>:</b> 0,00 INR
    Taxes<b>:</b> 0,00 INR
    Can anybody suggest how to go about this problem?
    Thanks in advance.
    regards,
    Yogesh

    Hi Yogesh,
    as far as i know, there is no standard functionality for that purpose, but there are workaround for it.
    1. Modify the BSP Application.
       Go to SE80 --> Repository Browser --> BSP Application --> your WI name --> page with flow logic --> double click on page1.htm --> Event handler tabstrip --> on the drop down selection press F1 --> add a function module that call you BPS function in specific event (e.g: OnInitialization).
    2. Use WI-Exit Class / WI-Extention (ABAP OO).
    Here you need to create sub class from Class: CL_UPWB_BSP_APPL, and assign the class to your WI. You can then add a function module that call you BPS function in method:
    2.1. Load --> performed only once on intial execution of WI.
    2.2. Initialisation --> called once for each server response.
    2.3. Dispatch --> called at each action and also for each WI component.
    You can see further information in SAP how to paper:
    How to Validate manual input in WEB planning application, New BPS-Features delivered with SAP BW 3.5, etc.
    You can call your BPS function with BPS API FM (See F.Group: UPC_API)
    But there is also more easier way to realize your ebit calculation. If you define your EBIT calc. manually in layout (define with manually defined Lead column). With this way, You will always get your EBIT analog with inputed values.
    Then you add your EBIT calc.function to Layout Component in WI in property: 'Function After Data Change'.
    Best Regards,
    Suan Liono

  • How can I find out the web interface a module function is executed from?

    Hello all,
    I was wondering if anybody knows how would be possible de determine the web interface a function is being launched from, within the function.
    I've got this function that is used for a exit variable that updates the variable value depending on another variable in a web interface. The thing is that this very same function and variable will be used in many web interfaces and the "source" variable will be different for each mask.
    So, for example, mask 1 will have variable 1 as a selector variable and variable X will be updated by it. Then I also have variable 2 in mask 2 as a selector variable and variable X will be updated by it as well.
    I want to develop a code, within the function module, that depending on the web interface that is calling it, it will use a source the correct variable and for this I need to know which web interface is calling the function.
    I hope to have been able to explain myself clearly. It's a purely technical question.
    Thanks in advance.
    Best regards.

    Hi Francesco,
    Are you talking about that ??? )) It will explain you about to get the name of the web page when you are executing an abap function for determining the values of variables...
    <a href="https://www.sdn.sap.comhttp://www.sdn.sap.comhttp://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/library/biw/g-i/how%20to%20make%20a%20variable%20even%20more%20flexible%20in%20bw-bps.pdf">How to make a variable even more flexible in BW-BPS?</a>
    This is weird: I wrote that document a few weeks ago, it is theorically published on SDN but this is not possible to find it by using the research tool... Maybe because it applies only to BPS in 3.5. I did not have enough time to migrate that solution to BI-IP 7.0.
    Regards
    Laurent

  • My contacts are not showing up on the PC app or the web interface.  Why isn't this working?

    My contacts are not showing up on the PC app or the web interface.  Message+ works fine on my Note 4 though.  My contacts are saved in my Google account.
    I've tried several things but message+ acts like there are no contacts in the app yet there are names and pictures in my conversations.  Can anyone help me?

        matthttam,
    Let's make sure that we get you up and running with no issues. I want to make sure that we are on the same page. Are your contacts actually listed in the address book on your phone? Are you using Verizon Messages? Or the third party Messages  from the Play Store? Please keep us posted.
    KevinR_VZW
    Follow us on Twitter @VZWSupport

  • Error while calling RFC when using BSP Web Interface

    Hi,
    we have a problem with the Authorization when we use an Web Interface for BSP. We have assigned all roles to the user which were mentioned in the SAP standard documentation:
    R_AREA   
    R_METHOD 
    R_PACKAGE
    R_PARAM  
    R_PLEVEL 
    R_PM_NAME
    R_PROFILE
    R_STS_PT 
    R_STS_SUP
    R_WEBITF 
    S_RS_ADMWB
    S_RS_AUTH
    S_RS_COMP
    S_RS_COMP1
    S_RS_DAS 
    S_RS_ICUBE
    but we still get the error message: "Error while calling RFC".
    When using a user with SAP_ALL, it works.
    What can we do?
    Thx for your time.
    Joerg

    Actually that's surprising - because BSP (Business Server Pages) and RFC (Remote Function Call) are not related; they use totally different transport protocols (http vs. RFC). Even if an BSP application is calling a function module remotely (acting as RFC client) no authorizations for S_RFC are required - in the calling system (but in the called system, i.e. the RFC server).
    Since assigning SAP_ALL seems to "cure" the problem, it seems to be an authorization issue, indeed. In that case it makes sense to use the authorization trace (ST01 - notice: that's specific to one single ABAP application server; you might have to activate the trace on multiple instances) to find out which authorizations are checked / demanded.

  • How to display popup at the web interface side while checking a sh cart

    Hi Experts,
    I have a requirement to get the popup while checking the shopping cart..
    I have implemented the badi BBP_DOC_CHECK_BADI..(Classic scenario)
    In this badi , i am using one RFC FM to check the item details availability in the backend..I am getting the desired functionality. But I have a specific requirement to show popup when the items in the shopping cart are not available in the inventory that is maintained the backend R/3 system..
    Can you please advise me how to write a popup in the web interface when stock is not available for a perticular item? Any HTML code available for the same?
    Please advise me?
    2) How to change status of an shopping cart item or else need to display some customized information for the item like 'This Item is in back order status '.
        The above situation arises when we are trying to check a shopping cart item status after ordering the shopping cart.
    thank you!!

    Hi Ravindranath,
    Try to add a standard message like:
    message e100(ZBBP_SC) into lf_dummy.
    clear ls_message.
    ls_message-msgty       = sy-msgty.
            ls_message-msgid         = sy-msgid.
            ls_message-msgno     = sy-msgno.
            shift ls_message-msgv1 left deleting leading '0'.
            select single text from t100 into ls_message-message
                                        where sprsl = sy-langu
                                          and arbgb = sy-msgid
                                          and msgnr = sy-msgno.
            append ls_message to et_messages.
    Regards,
    Marcin Gajewski

  • The URL in the web interface builder

    Hi
    In the web interface builder in BPS there are several components.
    When I click on them one by one I can see the planning functions and other details.
    There is a URL present in the web interface builder which corresponds to upload flat file data.
    How can we trace what are the planning functions used for this link.
    If we go to se80 how can we find whats the applicable BSP page for this particular URL which corresponds to a planning function.
    Please advise.
    Many thanks.

    Hi,
    From URL you can't find the details of planning objects. BUt you can find the BSP application that gets executed from that link and in that BPS application you can see the planning objects that are used in various events to upload the file data.
    Regards,
    Deepti

  • Sun x4170 ILOM - Can't get to the web interface 2 days after password reset

    Just bought a used x4170. I was able to get iLOM on the network and get to the web interface logon screen after setting the IP for it.
    I tried logging on but the password was not given to me. So I connected to the serial interface (rj45) from another machine and used putty to connect. Got to the preboot point and was able to reset the password to default, Rebooted.
    I was then able to log into iLOM. That was 2 days ago. Today for some reason, I can't get into iLOM. It pings but I can't get to the web interface. I get the IE error "cannot connect" or unable to connect or something like that.
    I'm completely new to this brand of server so consider me completely ignorant on all aspects of the hardware.......lol
    Thanks

    Hello
    By default, you connect to the server’s service processor (SP) using the out-of-band network management port (NET MGT). The ILOM sideband management feature enables you to select either the NET MGT port or one of the server’s Gigabit Ethernet ports (NET 0, 1, 2, 3), which are in-band ports, to send and receive ILOM commands to and from the server SP. In-band ports are also called sideband ports.
    You can refer more here : https://docs.oracle.com/cd/E19269-01/820-7959-11/820-7959-11.pdf
    If you want to use the NET MGT port of ILOM, then your output should display similar to below
    -> show /SP/network
    /SP/network
        Targets:
            interconnect
            ipv6
            test
        Properties:
            commitpending = (Cannot show property)
            dhcp_clientid = none
            dhcp_server_ip = xxxxxxxxx
            ipaddress = xxxxxxxxx
            ipdiscovery = dhcp
            ipgateway = xxxxxxxxx
            ipnetmask = xxxxxxxxx
            macaddress = 00:10:E0:65:2F:20
            managementport = MGMT   <<<<<<<<<<<<<<
            outofbandmacaddress = 00:10:E0:65:2F:20
            pendingipaddress = xxxxxxxxx
            pendingipdiscovery = dhcp
            pendingipgateway = xxxxxxxxx
            pendingipnetmask = xxxxxxxxx
            pendingmanagementport = MGMT    <<<<<<<<<<<<
            pendingvlan_id = (none)
            sidebandmacaddress = 00:10:E0:65:2F:21
            state = enabled
            vlan_id = (none)
    Hope this helps.
    Best Regards
    Bhavyesh

  • Values needs to be populated automatically in the web interface

    Hi,
    When the planner selects the value from a variable  in the web interface then automatically a planning function needs to be executed without pushing any push button.I do not use any planning folders as such.
    Could some one tell me how to achieve this functionality.
    points will be assigned.
    Thanks,
    Subha

    Hi Subha,
    You can assing default values to the Variables...Fiscal Year2008; Version100...etc. so that the user need not input all the variables.
    I am not sure whether you can assign a function--"on selection" of variables.  For better control It would be prudent to advise users to execute a function (if need be embed a SAVE function with in the sequence) on press of a button.
    Regards
    Srinivas

Maybe you are looking for

  • Migrating database from 9i to 11g.

    I would like to know that I wanted to migrate from database 9i to 11g so what has to be done. Wheather I can direct import the 9i dump file into 11g or I have to run the database upgrade assistant. Regards Alpesh.

  • How to add two datasets inside a same tablix?

    Hi Everyone, I want to create a report as using project server datas with two datasets in the same tablix.my report has three grouping by Months,Resources, and Resource Role.my dataset has resource name parameter.when i selected a few resource as fil

  • Sync issues with Windows 7 and Office 2010

    Just got a new computer running Windows 7. Downloaded and installed BB Desktop . When I try to sync with my Bold 9650 via USB cable I get message telling me that I have to have an internet connection to set up sync options. Never saw this message bef

  • Display of change docs in CUA

    Hi All, When we see the change docs in CUA system, it will only show the admin name for roles added to CUA client, for other child systems we need to check in respective systems. But in child system it will show that change is done by system user use

  • App- SleepMute doesn't work as they describes can i get a refund

    detail: my system is OS x 10.7.3, i want to mute the startup BONG sound@. issue: the "SleepMute" which is the app that i purchased on itune, it doesnt work as they describes on the photo "mute the startup sound"           My computer still bONgs... w