At max how many logical columns can be created in RPD

Hi All,
At max how many logical columns can be created in RPD. I have a requirement of creating 200 columns. Will there be any problem .
Is there any predefind number of columns for RPD creation??
Please help ..

Hi Annapurna,
There's no limit that I'm aware of or which is mentioned anywhere. Just as an example: I have a logical fact table with around 750 logical columns (>500 original measures & 250 derived measures). No issue whatsoever. Opening the presentation table through answers takes about 2-3 seconds (the NQSQL command has a lot to retrieve), but that's about it.
Cheers,
C.

Similar Messages

  • How many server nodes can you create per instance

    Hi,
    Very often the bottle neck in a java installation (NW04s) is the heap size. In order to increase the heap you simple create new server nodes.
    My question is:
    How many server nodes can you create per instance?
    Is there an upper limit before you have to create a new dialog instance (with a web dispatcher)?
    I can imagine that when you create a new server node you also have to increase the heap and max therad of the dispatcher. Is there any upper limit of the heap size of the dispatcher node ?

    Rasmus , I think you laid out a real good scenario for every one to contribute
    I may be very late but just updating this forum for benefit of everyone who visits this.
    In addition to all the points above one must also consider following things if one decides to add more server nodes to one dispatcher
    1.Garbage collection time
    2.Dispatcher would keep on sending request to node S2 if it is not completely bad and there by impacting all the servernode       so  you might end up restartiing the entire cluster.
    3,Debugging also becomes diffculy as you are not sure on which server node you are within the cluster.
    4.If you have something like F5 which does hear beat monitoring even one server node goes bad F5 will not report anything.
    So in my view one server node per dispatcher is an ideal configuration.
    Over All Dispatcher does not consume more resouces (Disk Space + CPU + memory ) at the same time it will give you maintenance flexibility.
    Nothing is right or wrong ,all these things are based on how your infrastructure set up is.
    Cheers !!
    Manish Jain

  • How many physical standbys can be created in one data guard environment?

    Hi Experts,
    How many physical standbys can be created from primary in one data guard environment? Why LOG_ARCHIVE_CONFIG limits up to 9 unique database names? Thanks.

    Victor Jin-Oracle wrote:
    Hi Experts,
    How many physical standbys can be created from primary in one data guard environment? Why LOG_ARCHIVE_CONFIG limits up to 9 unique database names? Thanks.
    Post the source of your information abouit the limit of 9 names.
    Even the Oracle doc shows 1..30 names in the same provided although that doesn't necessarily indicate a limit.
    https://docs.oracle.com/database/121/REFRN/refrn10237.htm

  • How many icloud account can we create with one ios device???

    how many icloud account can we create with one ios device???

    i need more then 1 account as i owe itunes some money and i cant access my app store so if i change my icloud account .....all my previous history wont be tracked

  • How many users/ schemas can we create in an oracle database?

    How many users can we create in an oracle database? Or how many users can oracle handle?
    Problem-
    I have to store information of ontologies (I will use countries instead) in db.
    I have to store information regarding countries.
    I have 13 tables in all to maintain for each country.
    Now there are two approaches:
    1) keep only 13 tables. Have an extra column in each table to indicate that a particular
    row stores information for which country.
    2) create a new user/ schema for each country. So we can get rid of the extra column
    needed in 1st approach.
    I have used the second approach. This is because number of entries in each table for a
    given country will be large.
    So initially when the s/w is installed I create a central-user. Each time data for new
    country has to be entered central-user creates a user/ schema, and creates tables for
    this user/ schema. The central user can access the tables of all the countries by
    country_name.table_name. By this approach I believe searching would be easy.
    If there is any flaw in my approach kindly mention it.
    Thank you

    There is no (practical at least) limit to the number of users & schemas you can have in Oracle.
    Your approach, however, is not going to scale nearly as well as the first option you outlined (adding a column). You are going to end up caching every possible variation of the various queries you're going to be executing because you will be referring to so many different tables, which is going to mean that you are doing a lot more work to parsing statements and generally churning through the shared pool. If you create enough users, you're liable to start hitting ORA-04030 errors because your shared pool is so fragmented.
    Additionally, you're likely going to end up with a whole lot of dynamically generated SQL to accommodate new schemas getting added over time which is going to cause you even more pain. Figuring out dynamically what table to join in is a heck of a lot more difficult for the programmer to write and for the database to handle than simply passing in a different country code.
    If you're concerned about having too much data, you can have your cake and eat it to by adding the country column and partitioning the tables based on country.
    Justin
    One other item I forgot to mention is maintainability. Having dozens or hundreds of "identical" schemas makes maintenance a huge pain because something like adding a new column now requires dozens or hundreds of separate DDL statements. You're almost guaranteed that some schema isn't going to be in sync-- it's going to miss a column or miss an index, etc.
    Message was edited by:
    Justin Cave

  • How many softMotion references can you create on an Interface Object

    I'm wondering how many softmotion references I can create on an interface object.  For example can I create a straight line move on an axis, keep that reference open then at the same time create another line move referece on a coordinate space that using that same axis?
    Can I have multiple line move references open at the same time on the same axis?
    Thanks,
    SteveA
    SteveA
    CLD
    FPGA/RT/PDA/TP/DSC

    Thanks Paul,
    I have noticed that the SoftMotion express vis open a reference on first call, but they never close the reference.  On my machine I will be doing regular coordinate moves and from time to time I will need to perform an Axis move.  Would it be better practice to close each reference after I perform the move?  How much overhead does it take to create a new reference?  The thought I had on keeping multiple reference open was to minimize the overhead in opening a reference.  Once my system gives a trigger to perform a move, I need it to be very responsive.
    Thanks,
    Steve
    SteveA
    CLD
    FPGA/RT/PDA/TP/DSC

  • How many logic remotes can you have

    I love the logic remote app and was wondering if it was possible to have it on multiple Ipads running at the same time with different views.
    This would be awesome to build a console of IPADs.

    Nope - only one LogicRemote connection to Logic.
    I'm sure that will come in the next upgrade. THis LogicRemote is such an amazin app with so many features and functionalities, it screams to have multiple LogicRemote connected at once.
    Hope that helps
    Edgar Rothermich
    http://DingDingMusic.com/Manuals
    'I may receive some form of compensation, financial or otherwise, from my recommendation or link.'

  • How many iCloud accounts can you create on Mac?

    I use different emails for different purposes (subscriptions,  shopping, forums, iTunes, etc.). With that in mind, I created 3 iCloud email accounts on my iPad and upon trying to register a 4th one I was told that this device is no longer eligible to create an iCloud account. Anyways, does the same rule apply to Macs (3 IDs per device)?

    Why not create aliases to your primary iCloud mail account for those other email needs.  That way you can access all emails from each of your devices with the same email client, Mail. On your Mac Just create a Rule to put emails to each alias in its own specific folder.
    OT

  • How many logical systems are required to connect between one XI and R3 sytm

    Hi Experts,
                   I need to know how many Logical systems we need to create when connecting an SAP XI and SAP R3 system.
    details wht I configured is as follows :
    For XI :  LOGSYSXI assigned to 100 client
    For R3:  LOGSYSR3 assigned to 800 client.
    Do I need to create two log'cal systems on one side?
    How many logical systems can a Client can support simultaneously? is it only one or more that one?
    THANKS IN ADVANCE.
    Sunil K Shetty

    Hi,
    >>>>I need to know how many Logical systems we need to create when connecting an SAP XI and SAP R3 system.
    as you've noticed you only need 2 - one for r3 one for XI
    this is enough
    also shown in my book:
    <a href="/people/michal.krawczyk2/blog/2006/10/11/xi-new-book-mastering-idoc-business-scenarios-with-sap-xi"><b>Mastering IDoc Business Scenarios with SAP XI</b></a>
    >>>>How many logical systems can a Client can support simultaneously?
    one per client
    but you can create as much as you wish
    wihtout connecting them to a client
    but use one for XI
    Regards,
    michal
    <a href="/people/michal.krawczyk2/blog/2005/06/28/xipi-faq-frequently-asked-questions"><b>XI / PI FAQ - Frequently Asked Questions</b></a>

  • At max how many columns is advisable to create in a table/view

    Hi All,
    I have two transaction table from which i want to create a simple view or materialized view. But the number of columns is about 200. So i want to know at max how many columns is advisable from the performance point of view.
    Even though i will create 200 columns in a view , for a perticular client installation i may not use all the columns.
    one more thing i will never use 200 columns in the select statement . At a time i will use only 4/5 columns.
    It may happen from this four column one column will be the 1st and 2nd column will be the 200th one.
    I want to know how it affects the performance and in which scenario . Please help if any body knows or already faced this kind of scenario.
    I am using oracle 10g .

    Annapurna Nayak wrote:
    thanks for ur reply .
    We are going to use this view in a report , so if i will create it as simple view it will affect report performance. because the view script is too long ...so every time quring to a view will decrease the performance.
    Are you asking me if it will? I think it probably won't but of course you have the means to test it to be sure, right?
    As u said MV should be done with minimum possible column . what can be the maximum column in MV ..??It would be defined by the limits on:
    * The maximum number of columns that a table can contain
    * The size of the query needed to define the select statement
    * Limitations on queries needed to maintain the data
    http://download.oracle.com/docs/cd/B19306_01/server.102/b14237/limits003.htm#i288032

  • How many key fields can we maintained in dso or ods

    HI
    pls let me know how many key fields can we maintained in DSO or ODS.
    Thanks and Regards.
    ASIM.

    Hi,
    Key fields can only be 16 you cannot exceed this. but if you have more key fields, you can combine fields using a routine for a key field
    Max Data Fields - 749 data fields can be added in a DSO.
    Regards,
    Marasa.

  • How many logic boards needed ?!!

    Yes. How many logic boards does a Powerbook G4 17" (1Ghz) need to work properly? Do they really have to be changed every year?
    I bought this beautiful machine secondhand. About 6 months later the screen seems to fail (stays black) i can us it only in Target mode as hard disk. The consulted Repair centre concludes: new logic board! Then they discover it already had been changed 26/07/2004 ; merely a year ago. But no more garanty. It isn't fair that such a expensive part and repair is only garanteed foor 3 months. Cost of this reparation: more than 700 euros !!!!! Apple customer care: "sorry, we can't do anything to help you" Who can then?
    Time to switch I suppose? What else can I do ??

    Sorry to hear that - not sure if you have any recourse based on the fact that it has already been replaced. If you have an up to date AppleCare contract then I would think it should be covered. In general I would say that your problem is somewhat rare. If main board failures every 6 months were common across the entire product line - or even just a subset such as the 17" - then there woudl have been a class action lawsuit resulting in a settlment that woudl provide extended warranty coverage.

  • Is there a limit to how many Podcasts you can post to iTunes

    I've been trying to post our most recent podcast to iTunes, and I haven't been able to. I've checked everything over and over and tried to repost, and have not been able to. I'm wondering if iTunes has a limit to how many podcasts you can post. Currently there are 83 podcasts that we' ve put up to iTunes. Each one is about 5-6 MB in size.
    Does anyone know if I've reached my max and need to remove old podcasts to make space for the new one?
    thanks. collintowne

    Thanks for the info. You're right. I never thought about it. That's what the whole RSS feed is all about. Telling iTunes where to get the info it needs. So iTunes doesn't store the actual files. Got it!
    I will try out that link you gave me. What I've been doing in the past to update my RSS/XML feed is just simply copy/paste the previous weeks info, update the new info, post it, and that's it. I never changed any of the information on the top part before you get to all the weekly posts. I did however for the first time attempt doing all of this on my Mac rather than use the PC that I have always done the Podcasts on and RSS feeds. So that must have caused a problem somewhere.
    collintowne

  • How many dunning levels can be defined ?

    < MODERATOR:  Message locked.  Please read the [Rules of Engagement|https://www.sdn.sap.com/irj/sdn/wiki?path=/display/home/rulesofEngagement] before posting next time. Suspected points abuse. >Hello friends
    Could u tell me,how many dunning levels can be defined ?
    regards
    AA

    hi anu
    Insap provides max 9 levels but all companies use 4 levels only.If u want use 9 levels also.
    At the time of FBMP configuration u cen give Dunning levels field 9.and then save.U cen run 9 levels inDUNNING RUN F150.
    Deifference is one level to another level DUNNING TEXT.
    Dunning text determines URGENCY OF DUNNING NOTICE.
    U cen give 9 levels dunning text also at the time of fbmp configaration
    Edited by: prasad k on Jul 11, 2008 3:14 PM

  • How many CPU cores can PS use?

    How many CPU cores can Photoshop CC (version 14.1) use at a max running on Mac OS X Mavericks? I have even looked into the PS tech specs but it only states multicore. Many thanks.

    I am wondering if CC has been further optimised for multi core, because AFAICR these results show more CPU use than the last time I bothered to check.  That would probably have been with CS6
    Image size (1000 pixels square to 10,000 pixels square)
    If memory serves, the lens blur filters made good use of system resources.  This was with Iris Blur
    I tried a few other filters on the 10k pixel image, but couldn't test my system enough to get a meaningful result.  I can hear my GPU fans ramp up with various actions even before I put them to serious use.  (I think the system starts working really early in the process.)
    I am assuming that Apple OS are similar to Windows.  Was there a specific reason you wanted this info, or just out of interest?

Maybe you are looking for

  • [SOLVED] Battery status in i3status is incorrect...

    So i3status suddenly seems to think my battery is fully charged at ~80%. At first I thought maybe my laptop's battery was going, but then I noticed if I run acpi -b when i3status is reporting full at ~80%, I receive the following: Battery 0: Charging

  • Migrating data from one screen to another though Table Control

    Hi Sapgurus, I am woking n the scenerio where i have two screen 100 and 200 now in 100 screen i have a Table Control, now i want that when i click on the row of this table control the selected row data should  be migrated to another screen. I have al

  • Problems with editing/opening PDF's in Acrobat X

    We have 2 situations going on with Acrobat X: 1.  We are scanning drawings on a Xerox Wide Format scanner to PDF's.  When I open them in Acrobat 8 Pro I can rotate and edit them.  When my boss opens them in Acrobat X the same file opens as a PDF/A an

  • Dvd not longer supported

    Illustrator cs3 down & dirty trick dvd, does not play on my mac, it says files not longer supported the back of the dvd says for windows and Mac, any solution ???

  • ESS - CLAIMS ERROR

    Hi One & All, Hope everyone is doing good. I have one issue when creating Claims request from ESS through Portal. When I click Create in Reimbursements / claims application, I have selected the Reimbursement type & Request type, then It is giving err