Hi ,
We have installed BW7.0 and EP 7.0 . Testing are running from Load runner with HP quality center. It is running some time properly and last minute we are getting error.
Basicalley performance testing is we are doing on the sap systems.
Cannot get connection for 60 seconds. Possible reasons: 1) Connections are cached within SystemThread(can be any server service or any code invoked within SystemThread in the SAP J2EE Engine), 2) The pool size of adapter "SAPFactory" is not enough according to the current load of the system or 3) The specified time to wait for connection is not enough according to the pool size and current load of the system. In case 1) the solution is to check for cached connections using the Connector Service list-conns command, in case 2) to increase the size of the pool and in case 3) to increase the time to wait for connection property. In case of application thread, there is an automatic mechanism which detects unclosed connections and unfinished transactions
Can some body help on this??
Regards,

Hi,
Any ways we can get the log of the error to see here.
Also see for replicating the problem couple of times, check the log if its different for different tries please paste all those logs here.
Regards,
Ravi

Similar Messages

  • Integration between Soluiotn Manager and HP Quality Center

    Hi Folks,
    I am currently configuring the integration between Solution Manager and HP Quality Center, and during the set up of communication user, I get the following error:
    User hpqc_comm is not authorized to access projects
    Message no. QC_INTEGRATION016
    Diagnosis
    You want to access projects in the Quality Center with the communication user hpqc_comm. This causes an error because the user either does not exist in the Quality Center or is not assigned to any project.
    Procedure
    Check whether the user hpqc_comm is in the Quality Center, and whether it is assigned to at least one project. Ask the Quality Center administrator to create the user and assign it to projects, if necessary.
    You can use another user for the communication
    Well, I have created that user in HPQC and assigned it to projects.
    Thanks for your help
    Marco

    the error is in Solution Manager. I am defining the communication parameters in SOLAR_PROJECT_ADMIN / <selected project> / edit / Connection to HP Quality Center. I choose the corresponding project in Quality Center, but when I validate the screen, I get the error I mentioned before, even though the communication user exists in HPQC and is assigned to that specific project.
    Thanks for your reply.
    Marco

  • UPK and HP Quality Center

    I am interested in obtaining information on how to integrate UPK with HP Quality Center. I know how to deploy the content - what I don't know are the next steps of the integration and what is involved. Does anyone have any information or experience to share?

    Hi,
    Any ways we can get the log of the error to see here.
    Also see for replicating the problem couple of times, check the log if its different for different tries please paste all those logs here.
    Regards,
    Ravi

  • Difference between Test workbench and HP Quality center

    Hello,
    What is the difference between SAP test Workbench and the HP Quality center? what is the advantage and disadvantage of each tool?
    Thanks in advance
    Hassan

    the error is in Solution Manager. I am defining the communication parameters in SOLAR_PROJECT_ADMIN / <selected project> / edit / Connection to HP Quality Center. I choose the corresponding project in Quality Center, but when I validate the screen, I get the error I mentioned before, even though the communication user exists in HPQC and is assigned to that specific project.
    Thanks for your reply.
    Marco

  • CoreTemp and Dual Core Center report differently.

    In CoreTemp I get Idle cpu (its a q6600 stock) temperatures near the 55° degrees while DualCore Center reports around 30°. If I go to the bios window it reports the same as DualCore Center, is there an issue??? BTW I have an P7N SLI-FI. When I run all other monitoring programs I have it says the same as CoreTemp so which program do I believe. If I run Prime95 multithreaded I get around 100° C - 120° C so I'm wondering since I don't want to fry my cpu...

    Quote from: Lugaidster on 17-July-08, 00:20:36
    In CoreTemp I get Idle cpu (its a q6600 stock) temperatures near the 55° degrees while DualCore Center reports around 30°. If I go to the bios window it reports the same as DualCore Center, is there an issue??? BTW I have an P7N SLI-FI. When I run all other monitoring programs I have it says the same as CoreTemp so which program do I believe. If I run Prime95 multithreaded I get around 100° C - 120° C so I'm wondering since I don't want to fry my cpu...
    I really wouldn't believe either  Dualcore center is rather buggy but not bad for reading voltage and temps I suppose. I'm going to recommend you try Realtemp, you can d/l it from techpowerup... http://www.techpowerup.com/realtemp/. It's highly accurate when calibrated per the documentation, and it explains in detail how your sensors work and also some really interesting information about C2D thermal properties. That's found here... http://www.techpowerup.com/realtemp/docs.php. The author has done extensive testing of intel cpu's to correctly determine tjmax and has written realtemp to be extremely configurable, accurate, and user friendly.

  • CUIS Contact Center Reporting Error

    I was getting this error on CUIS Reporting tool. I have developed a report using Database Query. My query runs successfully on SQL Server, but its making error in front end. Could anyone have solution on this?
    Thread was being aborted. at System.Threading.Thread.AbortInternal() at System.Threading.Thread.Abort(Object stateInfo) at System.Web.HttpResponse.End() at System.Web.HttpResponse.Redirect(String url, Boolean endResponse) at ViewerLauncher.Page_Load(Object sender, EventArgs e)
    Thanks,

    Hi,
    The Contact Center Simulation runs on the J2EE stack so you need to know your J2EE HTTP port and include that in your URL.
    http://<server>:<J2EE Port>/bcb
    The J2EE port is different from the HTTP/S port.
    Check with your basis team to know you J2EE port.
    Regards,
    Joost

  • History report error: | An Exceptional Error occurred. Application exiting. Check the log file for error 5022

    Hi all
    I've got a error msg when try to generate a report using Cisco history report tool:
    Error | An Exceptional Error occurred. Application exiting.  Check the log file for error 5022
    It only happens when choose report template: ICD_Contact_Service_Queue_Activity_by_CSQ_en_us.
    User tried samething on other PC, it working fine.
    only on user' own PC and only choose this report, error appears.
    user runing windows 7 and do not have crystal report installed
    tried reinstalled the software, doesn't work.
    also tried this: (https://cisco-support.hosted.jivesoftware.com/thread/2041254) - doesn't work
    then tried https://supportforums.cisco.com/docs/DOC-6209  - doesn't work
    attached the log file.
    thanks.

    wenqianyu wrote:From the log file:Looks like you get a Login Window.Error message showed up after username/password be enteredThere is an error in the log: Error happened in comparing UCCX version and HRC versionYou may need to do a clean uninstall, download the Historical report from the server, and install it again on the PC.Does this only happen to one PC or to every PC with this application?Wenqian 
    I have completely uninstalled the HRC, and download from server install again -- still doesn't work with exactly same error.
    this matter only happens on this PC, when user try same thing on other PC, it works.
    so i think it not relate to server or account.

  • Ports on various servers GRC, RWD, Loadrunner, Quality Center

    Y'all,
    With Governance, Risk, and Compliance on a Windows 2008 server, what ports should be open?
    Same for RWD, HP Loadrunner, and HP Quality Center.
    The port numbers, please.
    This is some hard to find info.  I've searched the Forums.  Not that it's not there, just not popping out.
    Thank you.
    Cheers!
    Edited by: Perry DuBard on Sep 26, 2011 4:07 PM

    Well, y'all, looks like if it's setting on a Windows box the port is 3389.  There might be need of a 8XXX something for some of the apps.
    Cheers!

  • HP Quality Center Adapter ST-QCA

    We've just installed solution manager 7.0 ehp1 sr1 and hp quality center.
    Is the adapter a separate purchased product for solution manager?
    Do I need to purchase and install ST-QCA in solution manager?
    Thanks,
    Daniel

    Is the adapter a separate purchased product for solution manager?
    Do I need to purchase and install ST-QCA in solution manager?
    The adapter works on 2 fronts, the SAP side and the HP side.
    The SAP Interface is free, and can be downloaded from the marketplace however, HP will sell you the Enterprise Integration Adapter which has to be bought along with BPT licenses if you decide to implement automated testing using Quick Test Pro and SAP TAO.
    Hope that helps
    Cheers!

  • FREC Error while Generating Reports in Quality Center

    Hi,
    We usually generate reports using Dashboard module of Quality Center . While generating reports on  a particular PC, we are getting the following error.
    The SQL Query <sheet1> has failed to run, with the following error:
    Returned Result is not valid FREC.
    We are able to generate the same report on a different PC.
    Does anyone encounter this issue earlier? Could someone help us out in solving this issue.

    Issue popped up with me a few times and seemingly uncontrolled.
    I resolved one query with replacing quotes in the string i.e. replace single with double by replace([field],chr(39),chr(34))

  • Quality Center 11 (ALM) Query - Integration with Subversion and Jenkins

    Hi OHPCPaT Forum,
    Are there any restrictions to enabling the QC integration with Subversion and Jenkins when the QC server is a SaaS cloud instance? Is there any additional config I should be aware of?
    Thanks in anticipation

    Hi,
    Yes all the users are facing the issue. Please find more details for the issue.
    Currently we are upgrading Quality Center 10.0 to 11.0 with HP Enterprise Integration module for SAP applications. The project successfully upgraded from QC 10.0 to 11.0 but there are some error popup for the project for which Application Module and Enterprise Integration for SAP applications Version 2.6 was enabled
    Quality Center Details:
    HP Application Lifecycle Management 11.00
    ALM patch level: 07
    Quality Center 11.00 Enterprise Edition
    Component     Build
    OTA Client     11.0.0.6051
    User Interface     11.0.0.6051
    WebGate Client     11.0.0.6051
    Test Run Scheduler     11.0.0.6051
    Execution Flow     11.0.0.6051
    Site Administration Client     11.0.0.6051
    Extension Version     
    Enterprise Integration for SAP applications     2.6.0.3232
    Sprinter     11.0.0.6051
    Application Model     2.6.0.917
    Installation Steps followed:-
    1.Installed HP ALM
    2.Installed Patch Service Pack 2 (Patch 2,3,4)
    3.Installed Patch 6
    4.Installed Patch 7
    5.Installed the Extensions HP Enterprise Integration module for SAP applications using Extension Deployment Tool by following the steps provided in the Addin Page
    6.Created new project in HP ALM
    7.Login to the project (no issue)
    8.Enabled the Project Extensions
    9.Login to the project (able to access the project but error message is popup when we access Test plan and Defect module)
    Note: There is no error when we access the project for which the HP Enterprise Integration module for SAP applications EI not enabled. QC 11.0 is not integrated with any tools.
    Let me know is there any step we missed or we need to do any manual steps we need to do before enabling EI

  • Profit Center Report and P&L difference

    Hi Experts,
    I have setup the following scenario with Profit Centers:
    I created a Profit Center called 'A' and another called 'B'.
    Then I created a Distribution rule 'AB' directly allocates 75% to A and 25% to B.
    I added an Invoice for a line total of $100 and used this Distribution Rule. This did pull through to the Journal Entry.
    My question is regarding the Profit and Loss Statement that will not pick up the Profit Center 'A' when I specify this in the Expanded button. This will however pick up the 'AB" for the total amount of $100.
    I would have thought that if I ran this only for 'A', I'll see the value $75 in the P&L....
    I looked at the Profit Center Report for this invoice and there I could see the $75 for the Profit Center 'A'.
    Please let me know what I'm missing, or if you are not able to see seperate Profit Centers in the P&L.
    Regards,
    Marli

    Hello Marli - are you running the Profit Center Report which shows that information???
    Path of Finances > Cost Accounting > Profit Center Report...
    I do not belive the profit center is on the Profit and Loss Statement (unless you set up each profit center with a specific GL Account Segment)...
    Take care - Zal

  • Error in Preview and Print in Crystal Report Viewer 2.0.0.7 in Workstation

    Hi Guys,
    I am encountering a problem when clicking preview and print in Crystal Report Viewer 2.0.0.7. It returns an error
    Unhandled exception has occurred in your application. If you click Continue the application will ignore and attempt to continue. If you click quit, the application will close immediately. Load report failed.
    I already install the runtime crruntime_120_mlb, . net framework 3.5 sp1 and the add-on itself. The viewer is working properly in SAP Server. My version of SAP is SBO 2007 A SP00 PL10.
    Regards,
    Michael

    here's the detailed error
    See the end of this message for details on invoking
    just-in-time (JIT) debugging instead of this dialog box.
    Exception Text
    CrystalDecisions.Shared.CrystalReportsException Load report failed. --- System.Runtime.InteropServices.COMException (0x80004005) The device is not ready.
       at CrystalDecisions.ReportAppServer.ClientDoc.ReportClientDocumentClass.Open(Object& DocumentPath, Int32 Options)
       at CrystalDecisions.ReportAppServer.ReportClientDocumentWrapper.Open(Object& DocumentPath, Int32 Options)
       at CrystalDecisions.ReportAppServer.ReportClientDocumentWrapper.EnsureDocumentIsOpened()
       --- End of inner exception stack trace ---
       at CrystalDecisions.ReportAppServer.ReportClientDocumentWrapper.EnsureDocumentIsOpened()
       at CrystalDecisions.CrystalReports.Engine.ReportDocument.Load(String filename, OpenReportMethod openMethod, Int16 parentJob)
       at CrystalDecisions.CrystalReports.Engine.ReportDocument.EnsureLoadReport()
       at CrystalDecisions.CrystalReports.Engine.ReportDocument.get_Database()
       at SAP_CR.MyForms.frmReportViewer.ConfigureCrystalReports()
       at SAP_CR.MyForms.frmReportViewer.frmReportViewer_Load(Object sender, EventArgs e)
       at System.Windows.Forms.Form.OnLoad(EventArgs e)
       at System.Windows.Forms.Form.OnCreateControl()
       at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)
       at System.Windows.Forms.Control.CreateControl()
       at System.Windows.Forms.Control.WmShowWindow(Message& m)
       at System.Windows.Forms.Control.WndProc(Message& m)
       at System.Windows.Forms.ScrollableControl.WndProc(Message& m)
       at System.Windows.Forms.ContainerControl.WndProc(Message& m)
       at System.Windows.Forms.Form.WmShowWindow(Message& m)
       at System.Windows.Forms.Form.WndProc(Message& m)
       at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
       at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
       at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
    Loaded Assemblies
    mscorlib
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3620 (GDR.050727-3600)
        CodeBase fileCWINDOWSMicrosoft.NETFrameworkv2.0.50727mscorlib.dll
    SAP_CR
        Assembly Version 2.0.0.7
        Win32 Version 2.0.0.7
        CodeBase fileCProgram%20FilesSAPSAP%20Business%20OneAddOnsSAP_CRSAP_CR.exe
    Interop.SAPbouiCOM
        Assembly Version 8.0.0.0
        Win32 Version 8.0.0.0
        CodeBase fileCProgram%20FilesSAPSAP%20Business%20OneAddOnsSAP_CRInterop.SAPbouiCOM.DLL
    System.Windows.Forms
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_MSILSystem.Windows.Forms2.0.0.0__b77a5c561934e089System.Windows.Forms.dll
    System
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3614 (GDR.050727-3600)
        CodeBase fileCWINDOWSassemblyGAC_MSILSystem2.0.0.0__b77a5c561934e089System.dll
    System.Drawing
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_MSILSystem.Drawing2.0.0.0__b03f5f7f11d50a3aSystem.Drawing.dll
    CustomMarshalers
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_32CustomMarshalers2.0.0.0__b03f5f7f11d50a3aCustomMarshalers.dll
    Interop.CR_Crypto
        Assembly Version 6.0.0.0
        Win32 Version 6.0.0.0
        CodeBase fileCProgram%20FilesSAPSAP%20Business%20OneAddOnsSAP_CRInterop.CR_Crypto.DLL
    System.Data
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_32System.Data2.0.0.0__b77a5c561934e089System.Data.dll
    System.Configuration
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_MSILSystem.Configuration2.0.0.0__b03f5f7f11d50a3aSystem.Configuration.dll
    System.Xml
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3082 (QFE.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_MSILSystem.Xml2.0.0.0__b77a5c561934e089System.Xml.dll
    System.Transactions
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_32System.Transactions2.0.0.0__b77a5c561934e089System.Transactions.dll
    System.EnterpriseServices
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3053 (netfxsp.050727-3000)
        CodeBase fileCWINDOWSassemblyGAC_32System.EnterpriseServices2.0.0.0__b03f5f7f11d50a3aSystem.EnterpriseServices.dll
    CrystalDecisions.Windows.Forms
        Assembly Version 12.0.2000.0
        Win32 Version 12.0.2000.840
        CodeBase fileCWINDOWSassemblyGAC_MSILCrystalDecisions.Windows.Forms12.0.2000.0__692fbea5521e1304CrystalDecisions.Windows.Forms.dll
    CrystalDecisions.Shared
        Assembly Version 12.0.2000.0
        Win32 Version 12.0.2000.840
        CodeBase fileCWINDOWSassemblyGAC_MSILCrystalDecisions.Shared12.0.2000.0__692fbea5521e1304CrystalDecisions.Shared.dll
    CrystalDecisions.ReportSource
        Assembly Version 12.0.2000.0
        Win32 Version 12.0.2000.840
        CodeBase fileCWINDOWSassemblyGAC_MSILCrystalDecisions.ReportSource12.0.2000.0__692fbea5521e1304CrystalDecisions.ReportSource.dll
    CrystalDecisions.CrystalReports.Engine
        Assembly Version 12.0.2000.0
        Win32 Version 12.0.2000.840
        CodeBase fileCWINDOWSassemblyGAC_MSILCrystalDecisions.CrystalReports.Engine12.0.2000.0__692fbea5521e1304CrystalDecisions.CrystalReports.Engine.dll
    System.Web
        Assembly Version 2.0.0.0
        Win32 Version 2.0.50727.3618 (GDR.050727-3600)
        CodeBase fileCWINDOWSassemblyGAC_32System.Web2.0.0.0__b03f5f7f11d50a3aSystem.Web.dll
    CrystalDecisions.ReportAppServer.CommLayer
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.1100.840
        CodeBase fileCWINDOWSassemblyGACCrystalDecisions.ReportAppServer.CommLayer12.0.1100.0__692fbea5521e1304CrystalDecisions.ReportAppServer.CommLayer.dll
    CrystalDecisions.ReportAppServer.ClientDoc
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.1100.840
        CodeBase fileCWINDOWSassemblyGACCrystalDecisions.ReportAppServer.ClientDoc12.0.1100.0__692fbea5521e1304CrystalDecisions.ReportAppServer.ClientDoc.dll
    CrystalDecisions.ReportAppServer.DataSetConversion
        Assembly Version 12.0.2000.0
        Win32 Version 12.0.2000.840
        CodeBase fileCWINDOWSassemblyGAC_MSILCrystalDecisions.ReportAppServer.DataSetConversion12.0.2000.0__692fbea5521e1304CrystalDecisions.ReportAppServer.DataSetConversion.dll
    CrystalDecisions.ReportAppServer.DataDefModel
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.1100.840
        CodeBase fileCWINDOWSassemblyGACCrystalDecisions.ReportAppServer.DataDefModel12.0.1100.0__692fbea5521e1304CrystalDecisions.ReportAppServer.DataDefModel.dll
    CrystalDecisions.ReportAppServer.Controllers
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.1100.840
        CodeBase fileCWINDOWSassemblyGACCrystalDecisions.ReportAppServer.Controllers12.0.1100.0__692fbea5521e1304CrystalDecisions.ReportAppServer.Controllers.dll
    CrystalDecisions.ReportAppServer.CubeDefModel
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.1100.840
        CodeBase fileCWINDOWSassemblyGACCrystalDecisions.ReportAppServer.CubeDefModel12.0.1100.0__692fbea5521e1304CrystalDecisions.ReportAppServer.CubeDefModel.dll
    CrystalDecisions.ReportAppServer.ReportDefModel
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.1100.840
        CodeBase fileCWINDOWSassemblyGACCrystalDecisions.ReportAppServer.ReportDefModel12.0.1100.0__692fbea5521e1304CrystalDecisions.ReportAppServer.ReportDefModel.dll
    BusinessObjects.Licensing.KeycodeDecoder
        Assembly Version 12.0.1100.0
        Win32 Version 12.0.0.840
        CodeBase fileCWINDOWSassemblyGACBusinessObjects.Licensing.KeycodeDecoder12.0.1100.0__692fbea5521e1304BusinessObjects.Licensing.KeycodeDecoder.dll
    JIT Debugging
    To enable just-in-time (JIT) debugging, the .config file for this
    application or computer (machine.config) must have the
    jitDebugging value set in the system.windows.forms section.
    The application must also be compiled with debugging
    enabled.
    For example
    configuration
        system.windows.forms jitDebugging=true
    configuration
    When JIT debugging is enabled, any unhandled exception
    will be sent to the JIT debugger registered on the computer
    rather than be handled by this dialog box.

  • Send and Recieve Error code " Receiving reported error (0x80004005): The operation failed"

    This is what is happening after installing 2010 on to a computer that was running 2007 Outlook.  Currently using Office 365 so everything is on the cloud but when the user sends one or two emails the error on the bottom of outlook says send and receive
    error. Then a pop up dialog box comes up with the following error
    Receiving reported error (0x80004005): The operation failed
    Does anyone know how to fix this
    Nexusxox

    Hi,
    Glad to know that you have found the solution.
    Thanks for your generous sharing. Have a nice day : )
    Thanks
    Mavis
    Mavis Huang
    TechNet Community Support

  • Getting an error while configuring VMM for System Center 2012. error - An internal error has occurred trying to contact an agent on the WIN-NTJU8CNU server: : . Ensure the agent is installed and running.

    Hi,
    I am trying to install "System Center 2012 - Virtual Machine Manager by Using a Pre-Configured VHD".
    I downloaded install guide & the binaries from http://www.microsoft.com/en-us/download/details.aspx?displaylang=en&id=10712
    I have followed the installation document & getting an error while configuring VMM for System Center 2012.
    error details from log file given below:
    01:12:24:VMMPostinstallProcessor threw an exception: Threw Exception.Type: Microsoft.Carmine.WSManWrappers.WSManProviderException, Exception.Message: An internal error has occurred trying to contact an agent on the WIN-NTJTNEJ1UCN.mydomain.com server: : .
    Ensure the agent is installed and running. Ensure the WS-Management service is installed and running, then restart the agent.
    01:12:24:StackTrace:   at Microsoft.Carmine.WSManWrappers.ErrorContextParameterHelper.ThrowTranslatedCarmineException(WsmanSoapFault fault, COMException ce)
       at Microsoft.Carmine.WSManWrappers.WsmanAPIWrapper.RetrieveUnderlyingWMIErrorAndThrow(SessionCacheElement sessionElement, COMException ce)
       at Microsoft.Carmine.WSManWrappers.WsmanAPIWrapper.Invoke(String actionUri, WSManUri targetUri, Hashtable parameters, Type returnType, Boolean isCarmineMethod, Boolean forceResponseCast)
       at Microsoft.Carmine.WSManWrappers.AgentManagement.AssociateLibrary(WsmanAPIWrapper wsmanObject, String CertificateSubjectName, String& ExportedCertificate, ErrorInfo& ErrorInfo)
       at Microsoft.VirtualManager.Setup.VirtualMachineManagerHelpers.AssociateAgentServer(String fullyQualifiedServerName)
       at Microsoft.VirtualManager.Setup.VirtualMachineManagerHelpers.AssociateDefaultLibraryServer()
       at Microsoft.VirtualManager.Setup.VirtualMachineManagerHelpers.SetupLibraryShare()
       at Microsoft.VirtualManager.Setup.InstallItemCustomDelegates.PangaeaServerPostinstallProcessor()
    01:12:24:InnerException.Type: System.Runtime.InteropServices.COMException, InnerException.Message: There is a time and/or date difference between the client and server.
    01:12:24:InnerException.StackTrace:   at WSManAutomation.IWSManSession.Invoke(String actionUri, Object resourceUri, String parameters, Int32 flags)
       at Microsoft.Carmine.WSManWrappers.MyIWSManSession.Invoke(String actionUri, Object resourceUri, String parameters, Int32 flags)
       at Microsoft.Carmine.WSManWrappers.WsmanAPIWrapper.Invoke(String actionUri, WSManUri targetUri, Hashtable parameters, Type returnType, Boolean isCarmineMethod, Boolean forceResponseCast)
    01:12:24:ProcessInstalls: Running the PostProcessDelegate returned false.
    01:12:24:ProcessInstalls: Running the PostProcessDelegate for PangaeaServer failed.... This is a fatal item.  Setting rollback.
    01:12:24:SetProgressScreen: FinishMinorStep.
    01:12:24:ProcessInstalls: Rollback is set and we are not doing an uninstall so we will stop processing installs
    I have completed MSSQL server configuration and while configuring VMM the below error displayed in the wizard:
    An internal error has occurred trying to contact an agent on the WIN-NTJTNEJ1UCN.mydomain.com server: : .
    Ensure the agent is installed and running. Ensure the WS-Management service is installed and running, then restart the agent.
    I have checked that the following services are running:
    1) Verified WS-Management srvice 2) MSSQL server + MSSQL (agent)  3)SC VM Manager Agent  4)  Windows management instrumentation .
    I have joined the VM (on which installing SC VMM) in a domain(as per install guide) and installing VMM using domain account & it is in local Administrators group.
    Also I would like know if there is any stand alone SC VMM installer. If yes then please let me know the installer location & install guide.
    thanks.
    ====

    Have you installed AppController on the same machine with VMM?

Maybe you are looking for

  • Printing address bar codes in Appleworks

    I use the database function in Appleworks to make a custom invoice system. Each 8.5" by 11" database "card" is an invoice. Prints out very nice, and I spaced things so it fits perfectly in a #9 Window envelope. Problem is I would like to make more pr

  • Trouble after reinstalling iTunes on PC

    Hi guys. I had to reinstall iTunes on my PC and I notice that I no longer have my original playlists and such. Yet thy are still on my other devices. How do I syncs my iPod without it going to the way my PC is? I don't want to lose any songs/playlist

  • To write a single query to get the desired output.

    Hi, I have table by name "employees" it contains 20 records meaning 20 employee details. some of the column it contains are employee_id,Hiredate as below. EMPLOYEE_ID|HIRE_DATE 100|6/17/1987 101|9/21/1989 102|1/13/1993 103|1/3/1993 104|5/21/1991 107|

  • Table height in layout development

    Hello there,                I have defined a table in the layout which has a header and a row. Now, I have another table is displayed (using repeating subforms not with standard table layout). When my data is getting printed, if the inner table is bl

  • Deprec. area data can be changed despite view authorization

    Hi, Users with Asset view '03' (ie authorization to change master data for only tax depreciation areas-10,11,13 & 40) are able to change values in asset master for all deprecation areas. I applied note 1316246 and in user role restricted the AA_VIEW