ChaRM Error - "No maintenance cycle is open for the current system"

Hello All,
I am setting up ChaRM in development system after EGI session with SAP support. I have copied standard transactions to custom ones and created Maintenance and Implementation project to run test of all scenarios.
I now come across error of "No maintenance cycle is open for the current system" after I create a change request and in the change document, I cannot see it link with task list and the error message is displayed. I tried it with custom transaction as well as standard SAP transaction (SDCR) and get the same error.
What links a document to a maintenance cycle? Where can I see the config of this setup? I am trying to see where it is broken. I am using the correct IBASE number (production client in logical component), I tried to create a new logical component, new projects with correct settings but it still gives this error message. Please advice.
Thanks and regards,
Nischal

Hi
did you also unlock the maintenance cycle and open for changes in solar_project_admin by right click
do check this blog
/people/dolores.correa/blog/2009/07/23/change-request-management-scenario-working-examples
/people/dolores.correa/blog/2009/07/23/change-request-management-scenario-working-examples-final-points-and-appendix
Question no 17
/people/dolores.correa/blog/2009/07/22/change-request-management-scenario-usual-questions-and-known-errors
Hope it solves
Regards
Prakhar

Similar Messages

  • Charm implementation: No maintenance cycle is open for the current system

    Gurus,
    I'm in implementation project to use charm.
    I've created SDCR using charm_create, and choose transaction type subject "Development (implementation)"
    After approving the change request, so that the status become "Approved", I re-open the request to set into "in development", but there's error:
    "No maintenance cycle is open for the current system"
    I've checked notes and search the forum but not relevant to my subject.
    Please help.
    Regards,

    Hi Cesar,
    I'm facing this issue now. I have followed Dolores blog
    - The IBase is wrong: The IBase/component must represent the production system in the project landscape. RP1 is my production
    - Lack of authorizations: Assign role "SAP_SOCM_ADMIN" or "SAP_CM_ADMINISTRATOR_COMP" (or equivalent) to the user who would like to approve the change request. I have updated all roles and given the users SAP_ALL
    - Project is locked in table /TMWFLOW/PROJMAP: If an error is detected during the processing, then the project might be locked in this table. The customer can unlock it by pressing the refresh button under tab "System Landscape" -> "Change Requests". If there are other error messages shown during the refresh process, the customer must fix those errors beforehand. Refreshed it many times without errors
    I'm on the latest level of Solman 7.1 SP8, I have implemented all the new notes as well.
    I have attached a screenshot
    To me it seems like a bug, but haven't found anything on marketplace. Any help is much appreciated.
    Cheers
    Jimmy

  • Error "No maintenance cycle is open for the current system"

    Hi,
    I'm setting up the ChaRM for test purposes.
    I have done everything according to SAP Expert Guided session requirements (like Basic configuration, Landscape and TSMS set-up) and also was reading and checking the following Blog " Change Request Management scenario: Working examples"
    /people/dolores.correa/blog/2009/07/23/change-request-management-scenario-working-examples
    Everything seems to be ok:
    1) Landscape ok, IBase created and active, Partners assigned to each component
    2) Maintenance project created and Maintenance cycle set to "Development with release"
    3) I can easily create Change request (I tried Normal correction), approve it.
    4) When I open Change Document for approved change reques - it gives error "No maintenance cycle is open for the current system" and I can't proceed with setting Change document status to "In development".
    In Change Request I indicate the only IBase (1) and as Component - SolMan clent 803, whish is set-up like PRD.
    What could be wrong?
    I tried reading all threads but did not get solution - there were suggestions to activate maintenance cycle (in my case it active), to check if business partners are assigned to IBase components (in my case done),
    What else?
    Thanks in advance,
    Ausra Gustainiene

    Hi Ausra,
    Please, take a look at this topic:
    Change Request Management scenario: Usual questions and known errors
    /people/dolores.correa/blog/2009/07/22/change-request-management-scenario-usual-questions-and-known-errors
    17. Error: "No maintenance cycle is opened for the current system"
    Best Regards,
    Fernando Rocha

  • No maintenance cycle is open for the current system

    Hello!
    I have problems to use CharM functionality due to following error:
    <b>No maintenance cycle is open for the current system</b>
    The error arises when I try to set a urgent correction in status "In Development" I get the following error, menwhile I have an valid maintenance cycle active.
    I use CharM functionality for the solution consisting of an single system with two clients:
    SRM:000 (as DEV-system) (system role: source system)
    SRM:100 (as PRD-system) (system role: target system)
    - No maintenance cycle is open for the current system (meanwhile I have a valid maintenance cycle created and activated).
    Futhermore I get the additional warning:
    IBase component is not a productive system in system lanscape
    Can some help me with this issue?
    Thank you very much!
    regards
    Thom

    Hello Kriti,
    thank you very much for your response.
    Unfortunately I also thought about it.
    Basically my CharM procedure looks as follows.
    I send the message from productive client (I have only one system with client 000 and 100)  to Service Desk in SOLMAN.
    There I can see the IBase of the productive client.
    Then I create a urgent correction by assigning IBase to this IBase of productive client. It is also possible to change the IBase in change mode, so I have tried all the possible values of IBase and get the same error.
    My problem also is that I have multiple values of IBase assigmenets, it means one system has multiple assigments to IBase components.
    I do not know how to delete/cut these settings....
    Thank you for your further help!
    regards
    Thom

  • No Maintenance Cycle is open for current system

    Hi Experts,
    We are facing a peculiar problem in ChaRM implementation.
    We have successfully created the maintenance cycle .But when we try to create change transaction & get it approved then it is showing an error : " No Maintenance cycle is open for current system".
    We have checked all the configuration like STMS & system landscape too. All are working fine.
    Any help will be appreciated.
    Pooja Mittal.

    Hi,
    you might have different reasons why it is not working
    1 check the status of the tasklist (or cycle) and of your project (service desk document) (via SOLAR_PROJECT_ADMIN)
    2. check your authorisation for project
    3. check the subject code of the change request (Implementation or Maintenance project ?) check
    CRMD_ORDER on your change request
    4. check the type of project you have activated (should match the above subject code) via SOLAR_PROJECT_ADMIN
    5. check the target system of your change request : it should be a  productive environment
    I hope it helps
    br Xavier

  • Error "codepage could not be determined for the receiver-system"

    Hi,
    we use the idoc-adapter to send message from mySAP ERP to PI.
    All worked fine.
    So, this morning I have changed the datatype of the messageId from "char" to "int" in mySAP ERP in the customizing menue (install param). So, no message received in SAP PI.
    When I start transction "we05" in mySAPERP" I get the following error:
    "codepage could not be determined for the receiver-system" status 02.
    I have changed the datatyp to "char" but the same probleme
    Can anybody help me please?
    Regards
    Stefan

    This error shouldn't occur unless there is some modification at the OS level codepages.
    Please check the entried in the RFC destination for connecting to the XI system. Unicode settings.
    Regards,
    Prateek

  • Should OKP1 being all closed and only be opened for the current period ?

    Guyz,
    In OB52 (Financial closing period) , only "open period" being input on it. So, basically the closing period in OB52 is by opening the period provided to be posting.
    Then how about OKP1?
    It's provided to lock the actual period , actual transactions, or to lock the plan period or plan transactions..but the question is:
    a. Should it be all closed (ticked mark all transactions & all periods) except for the current period that is provided to be posting as period determined in OB52...For example, it is now June, then all periods & transactions other than June is being ticked mark.
    OR
    b. Should it be all opened except for the period that is being closed? For example, it is now June, so periods & transactions of period January to May are being ticked mark (closed).
    Which of the options is the best practice?
    Need your answers asap plz.... Thanking you ..

    Hello,
    For example in OB52, if you have opened for June, i.e.,
    06 of 2009 to 06 of 2009 (1st Period)
    In such case,
    In OKP1, you need to only untick June for all the months and close all remaining months (Untick June and tick all other months and transactions).
    Note that your planning activities for all the year must have been completed. Otherwise, you cannot enter the plan values.
    Regards,
    Ravi

  • Set Change to 'Development' : ERROR: No maintenance cycle

    Hello,
    i have customized the change management scenario in SolMan 4. Now that I have approved a change request I want to set the change to 'development'. But the error No Maintenance Cycle appears.
    I have assigned a maintenance project to my Solution. I have actived the change management in the maintenance project, but as i wanted to push on the create task list button the message appears that my project ist not released yet, cycle can not be created.
    Please could you explain me how to create a maintenance cycle, what are exactly the necessary steps and why I need a maintenance cycle, for example for creation of a new user??
    Thank you in advance!!
    Regards
    Marcus

    Hi Ausra,
    Please, take a look at this topic:
    Change Request Management scenario: Usual questions and known errors
    /people/dolores.correa/blog/2009/07/22/change-request-management-scenario-usual-questions-and-known-errors
    17. Error: "No maintenance cycle is opened for the current system"
    Best Regards,
    Fernando Rocha

  • Getting error "You have insufficiant priviliges for the current operation"

    Hi,
    we are calling one seeded self service page from one custom self service page. But it is showing error like *"You have insufficiant priviliges for the current operation. Pls contact your system administrator."* Pls advice how to resolve this issue.
    Thanks in advance,
    Hanimi.....

    Hanimi
    This can be possible that in the instance in which it is working, In that the user with which you are testing the page is having access to that particular responsibility to which this page is attached.
    So try to assign this page's responsibility to your user and try again.
    Thanks
    AJ

  • Node id does not exist for the current application server id

    Hi gurus,
    when i start application services (adstrtal.sh) i encounter the following error: Node id does not exist for the current application server id.
    i executed the command select server_id from fnd_nodes and had the following output
    SERVER_ID
    991D192B1CFC10F2E043C0A8645210F226563381082071204628231314463687
    i also checked the .dbc files under $FND_TOP/secure, there were two HOSTNAME_SID.dbc files (IPPDDVP_VIS.dbc and ippddvp_vis.dbc) with different APPL_SERVER_ID
    ippddvp_vis.dbc == 9827D18C8C2E8816E043C0A86452881611641850934523625093287478849136
    IPPDDVP_VIS.dbc == 991D192B1CFC10F2E043C0A8645210F226563381082071204628231314463687
    Please help me out.
    thanks.

    i cleaned the FND_NODES TABLE as per metalink note 260887.1. i run autoconfig on db/apps tier. Now when i start the application, i encounter the following error:
    applmgr >./adstrtal.sh apps/apps
    You are running adstrtal.sh version 115.19
    Executing service control script:
    /dvp2/product/viscomn/admin/scripts/VIS_ippddvp/adapcctl.sh start
    script returned:
    adapcctl.sh version 115.55
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    Apache Web Server Listener is not running.
    Starting Apache Web Server Listener (dedicated HTTP) ...
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    Apache Web Server Listener (PLSQL) is not running.
    Starting Apache Web Server Listener (dedicated PLSQL) ...
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    adapcctl.sh: exiting with status 0
    .end std out.
    .end err out.
    please what should i do next to resolve this problem.
    thanks

  • SFLIGHT is NOT defined for the current logical database.

    I have just started learning ABAP and bought an ABAP Objects book by Horst Keller. I have installed 4.6d mini sap and SAP GUI 6.4 on win XP Prof. I executed S_FLIGHT_MODEL_DATA_GENERATOR to load DB tables.
    (1). When I tried to check a sample program, I get an error message SFLIGHT is not defined for the current logical database.
    Here is the partial code:
    REPORT zbcb01f1 .
    TABLES: sflight, sbook.
    DATA: BEGIN OF sr OCCURS 100,
          carrid LIKE sbook-carrid,
          connid LIKE sbook-connid,
          fldate LIKE sbook-fldate,
          bookid LIKE sbook-bookid,
          order_date LIKE sbook-order_date,
          loccuram LIKE sbook-loccuram,
          END OF sr.
    GET sflight.   <---- Error is pointed here
    (2). I am also not getting Graphical Screen Painter when selecting Layout for a screen. Instead, I am getting alphanumeric editor.
    Someone please help me.  
    Raizak.

    Hi Raizak,
    the easiest way is to go to service.sap.com/notes and enter the note number. For this time I've copied the 2 notes below.
    Best regards,
    Christian
    Symptom
    The Graphical Layout Editor of the Screen Painter either does not start or terminates.Error message 37527 is displayed in the session in which the call was made (Graphical Layout Editor not available.
    Additional key words
    () EUNOTE, EUSCREENPAINTER, 37 527
    Cause and prerequisites
    This note comprises all the common causes for error message 37527 and provides you with information on how to systematically trouble shoot the problem.
    1. Windows32 or UNIX/motif?
    As of Release 4.6B there is only the program version for 32bit Windows (NT, 95, 98, 2000 ff.).Up to Release 4.6A there was also a version for UNIX/Motif.All of the more current notes (with the exception of Note 45490) refer only to the Windows version.
    2. Termination at the start or during use?
    The following diagnostic steps refer to the causes of the errors which prevent the Graphical Layout Editor from starting. However, there are also known error causes, which result in the program terminating when the application is being used and which also produce the 37527 error message. This affects -
    Rel.4.6C/D: Termination when attempting to read texts in the logon language -> Note 375494
    Crash after transferring program and dictionary fields. Termination after transferring program and dictionary fields -> Note 189245
    Release 3.1I: Termination after inputting field text -> Note 113318
    3. Is the SAPGUI installation correct?
    The Graphical Layout Editor is automatically installed during the standard installation of the SAPGUI.If you chose a non-standard installation, then you should have explicitely selected its installation (component "Development Tools - Graphical Screen Painter").
    The program executable is called gneux.exe.During the SAPGUI installation it is placed in the same directory as the SAPGUI programms (for example, front.exe) (usually C:\Program Files\SAPpc\sapgui). The following belong to the program:
    - An additonal executable gnetx.exe (RFC starter program)
    - the DLL eumfcdll.dll
    - various eusp* data files (that is, the names all begin with eusp.)
    You can check the completeness of the program installation by starting the program gneux.exe locally in the SAPGUI directory (for example, by double-clicking on the program name in the Explorer window).The Layout Editor is displayed with German texts and an empty drawing area for the pseudo screen EUSPDYND 0000.
    If the installation is not complete, an error dialog box provides information regarding the cause of the error, for example, sometimes the DLL eumfcdll.dll is missing after reinstalling the SAPGUI. For example, the eumfcdll.dll DLL was sometimes missing after the SAPGUI was reinstalled.
    4. System link defined and okay?
    The Graphical Layout Editor is a separate program which is started by the Screen Painter Transaction (SE51) on the Frontend machine.
    Up to Release 3.0F, the programs communicated with each other via the graphics log of the SAPGUIs (gmux).The definition of the environment variable SAPGRAPH may be the cause for the program not being being found where it is.
    As of Release 3.1 G, the programs use a separate RFC link which is set up in addition to the SAPGUI's RFC link.Missing or incorrect definitions of the RFC destination EU_SCRP_WN32 or problems with the creation of the RFC link are the most frequent causes for error message 37527 being displayed.Below you can find the correct settings for the RFC destination EU_SCRP_WN32 (under "Solution").Note 101971 lists all the possible causes for problems with the RFC link set-up. Attention:The Graphical Layout Editor may not be operated through a firewall (for example between the SAP and the customer system) because this does not allow an additional RFC connection in addition to the SAPGUI.
    Solution
    ad 1 UNIX/Motif
    Note 45490 describes possible errors resulting from an incorrect program installation under UNIX/Motif (up to Release 4.6A).
    ad 2 Termination when using
    The above-mentioned notes may contain options for solving individual problems.However, you usually have to replace the program with an corrected version.You can do this either by downloading a patch from sapservX or by installing a more current SAPGUI.The patch is mentioned in the respective note.
    ad 3 Installation
    You either need to reinstall the SAPGUI or manually copy the missing file into the SAPGUI directory.In both cases you should make sure beforehand that a Graphical Layout Editor is no longer running.To do this you can either remove all processes gneux.exe from the process list by using a tool such as Task Manager (on WindowsNT) or exit the Graphical Layout Editor from the Screen Painter Transaction menu via Edit -> Cancel Graphical Screen Painter). Attention:For each session or system an individial Layout Editor process may exist so that, if need be, several processes should be cancelled.
    ad 4 System link
    Up to Release 3.0F:you can either delete the environment variable SAPGRAPH or copy all the files of the Graphical Layout Editor into the directory which is specified by SAPGRAPH.
    As of Release 3.1G:you can use Transaction SM59 to check the RFC destination EU_SCRP_WN32 (expand the TCP/IP connections, select destination EU_SCRP_WN32).If the destination is missing, then you should create it with the following settings:
    - Connection type "T" (start of an external program via ...)
    - Activation type "Start"
    - Start on "Front-end workstation"
    - Front-end workstation program "gnetx.exe" (caution! NOT gneux.exe)
    - Description (optional) "Graph. Screen Painter (Windows32)
      Start Program gneux.exe using the gnetx.exe starter program."
    If you want to start the program from a different directory than the SAPGUI standard directory, then replace the default value under Frontend work station by the complete path name for program gnetx.exe.Transaction SM59 also allows you to check the RFC connection via the pushbutton "Test connection").In this case the system attempts to localize and start the program gnetx.exe.If there are errors, a message is displayed regarding the possible causes (for example, gateway problem, timeout problem or the like).Note 101971 provides a detailed explanation of the problems involved with an RFC connection set-up.As the Graphical Screen Painter requires a functional RFC connection as of Release 3.1G, contact the System Administrator or create an message on the topic Middleware (BC-MID-RFC) if you encounter RFC problems.
    If the program gnetx.exe can be found and started, the banner dialog box with logo, release data and version number is displayed briefly.As the Layout Editor itself is not started, the error cause must be in the installation of the Layout Editor program gneux.exe if the connection test was successful.
    Release 4.5A to 4.6B: Use with Releases <3.1G>.
    The Graphical Layout Editor is downward-compatible as regards the system connection, that is, an RFC-based Layout Editor for example from Release 4.6C can also be used on a non-RFC-based Screen Painter, for example of Release 3.0F.However, the releases mentioned above have a program error which causes a crash due to memory violation in the start phase of the program.Note 197328 describes the solution by installation of the corrected program version.
    Important: Trace file dev_euspNNN!
    If none of the diagnosis steps leads to the cause of the error and to the solution of the problem via the corresponding note, then you should add the contents of the trace files dev_euspNNN (NNN = process number) to the message for SAP, if possible.You can find this file in the current directory of the SAP System, for example under Windows NT in C:\Winnt\Profiles\<user>\SAPworkdir.If several such trace files can be found there, make sure that you use the file which matches the termination time with respect to date and time of creation.In most cases the ERROR message in the last lines of this trace file provides an important note on the cause of the error.
    Source code corrections
    Symptom
    The graphic layout editor of the Screen Painter cannot be started (RFC version).
    Other terms
    () EUNOTE, EUSCREENPAINTER
    Reason and Prerequisites
    This is generally caused by the fact that the RFC connection between the frontend graphics layout editor and the calling screen painter program at the backend cannot be set up.
    Possibility 1: Route permission denied
    In the trace file dev_eusp<Process Id> of the graphics layout editor you find the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR route permission denied (<Front-Id> to <BackId>,<Service>)".
    If there is a firewall between frontend computer and application
    server, you need to decide whether the port for the RFC of the graphical layout editor can be released here (see Solution 1 below).
    In case no firewall exists between the frontend computer and the application server, in its route permission table, the SAProuter contains either no entry for the frontend computer, on which the graphics layout editor is started, or the entry says that the link is saved by a password.Since the connection is denied, the graphics editor processes exits again, and the screen painter switches to the alphanumeric layout editor.
    Possibility 2: Service 'sapgw<ServiceId>' unknown
    In the trace file dev_eusp<ProzessId> of the graphics layout editor you have the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR service 'sapgw<ServiceId>' unknown".
    The service sapgw<ServiceId> (for example, sapgw00) is not known on one of the computers participating in the RFC communication because the corresponding entry is missing in its service file. The affected computer can be the frontend computer or the gateway computer.
    Possibility 3: The system parameter gw/cpic_timeout value is too low
    This system parameter determines how many seconds the gateway is waiting for the RFC connection to be set up.In case of a high network load, the default value of 20 seconds is too small with the result that the connection cannot be created on time.Here the graphics layout editor process also exits with the trace file entry "ERROR in RFCMgr_accept: not accepted".
    Possibility 4: System parameter abap/no_sapgui_rfc set
    The profile parameter abap/no_sapgui_rfc of the system is set (that is, it has a value not equal to space or 0).This prevents the program of the graphics layout editor from being started with RFC at the frontend.
    Possibility 5: Unnecessary authorization check
    The error message "No RFC authorization for user xxxxxx" is generated although the check of the RFC authorization was deactivated by profile parameter auth/rfc_authority_check (value = space or 0). The problem is caused by a program error, that ignores the value of the profile parameter let during the call of the RFC authorization check (see Note 93254). This error can occur as of Release 4.5.
    Solution
    ad 1) If a Firewall is installed between frontend computer and the application server, you need to decide whether the port for the RFC link of the graphical layout editor shall be released in the firewall. This is port 33nn, where nn is the 2-digit system number of the SAP application server. As of Release 3.1G, the graphical layout editor needs an RFC link for communication with the application server in addition to the already existing linkof the SAP GUIs. Such a second link is not allowed by the firewall in general because it would contradict the security concept (password protection, logging of the connection).
    If no firewall exists, you should check whether the frontend computer can be added to the route permission table or whether the password option can be removed from out of the available entry.
    For details refer to chapter 4.4 of the attached Note 30289.
    ad 2) Include service sapgw<ServiceId> in the service file.
    Refer to Note 52959 for details.
    ad 3) Increase value for system parameter gw/cpic_timeout. 60 seconds should be sufficent as a timeout limit.
    ad 4) Set the system parameter abap/no_sapgui_rfc to space or 0
    Start the application server so that the new parameter value comes into effect.
    ad 5) Import the Support Package specified in the attachment for the release in question or implement the advance correction in the source code as described in the attached correction instructions.
    As a workaround, assign RFC authorizations as described in Note 93254.

  • Error: "File couldn't be opened for writing" with CinemaDNG sequence

    Using a Premiere Pro > After Effects workflow with my colorist.
    I created a project in Premiere CS6 and used MOV transcodes because Premiere CS6 does not read CinemaDNG sequences. I do not have CC installed on my computer. My colorist, on his computer (we are both using Mavericks), imported the .prproj into AE CS6. We tried to replace MOV files with CinemaDNG sequences, and AE returned this error:
    After Effects error: File couldn't be opened for writing: "[file path]". ( 3 :: 0 )
    Normally when you replace footage with a CinemaDNG sequence in AE, Adobe Camera Raw pops open so you can make changes before the file is important. I have never seen this error before.
    My colorist has CC installed as well as CS6, so we tried that instead.
    Colorist opened the Premiere CS6 project in Premiere CC, creating a new Premiere CC project. Replaced MOV files with CinemaDNG sequences within Premiere CC with no error, project plays fine in Premiere CC. Finally! So we imported the new Premiere CC project in AE CC, and all linked CinemaDNG sequences appear as color bars (unlinked footage). When testing to import a CinemaDNG sequence, AE CC returned the same error as AE CS6.
    So we tried opening the same CinemaDNG files in Photoshop CS6 and Photoshop CC to see if there was an error with Camera Raw. Both versions of Photoshop open the CinemaDNG files correctly in Camera Raw (version 8.3). So now we have CinemaDNG files functioning properly in Premiere Pro, Photoshop, but... not AE?
    Tried replicating this on a second, Mountain Lion computer with both versions of AE, and returned the same issue.
    CinemaDNG files from a different source DID open in AE CC and AE CS6 on both computers, which leads me to believe there is some kind of permissions/metadata issue in this particular set of CinemaDNG files I'm using that's causing problems for AE, but NOT Premiere Pro or Photoshop. Anyone experience anything like this?

    try the "oddball problems" fix:
    http://www.bulletsandbones.com/GB/GBFAQ.html#oddballprobs
    (Let the page FULLY load. The link to your answer is at the top of your screen)

  • Main optimizer error - There is already a transaction for the system

    Hi Guru's,
       I am trying to download support packs from maintenance optimizer in solution manager system. When i select the logical system it gives the error
    'There is already a transaction for the system of this product version'
    After this error, it does not proceed further.
    There is many maintanence transactions in Maintanence optimizer. Now how to remove all these.
    Any ideas or solutions most welcome.
    Moses

    As Christian has already written, the only problem is that there is already an open Maintenance Transaction for that specific system. Maintenance Optimizer checks that you do not open two different Maintenance Transactions for a system at the same time.
    You only have to withdraw the old Maintenance Transaction to be able to proceed with the new one. Open the old Maintenance Transaction and click "Withdraw" on the bottom of the page. If it is grayed out, you need to go one step backwards, there you can withdraw it.
    Best regards,
    Joachim

  • Bulk load data conversion error (type mismatch or invalid character for the specified codepage) for row 1, column 3 (NumberOfMultipleMatches).

    Hi,
    I have a file where fields are wrapped with ".
    =========== file sample
    "asdsa","asdsadasdas","1123"
    "asdsa","asdsadasdas","1123"
    "asdsa","asdsadasdas","1123"
    "asdsa","asdsadasdas","1123"
    ==========
    I am having a .net method to remove the wrap characters and write out a file without wrap characters.
    ======================
    asdsa,asdsadasdas,1123
    asdsa,asdsadasdas,1123
    asdsa,asdsadasdas,1123
    asdsa,asdsadasdas,1123
    ======================
    the .net code is here.
    ========================================
    public static string RemoveCharacter(string sFileName, char cRemoveChar)
                object objLock = new object();
                //VirtualStream objInputStream = null;
                //VirtualStream objOutStream = null;
                FileStream objInputFile = null, objOutFile = null;
                lock(objLock)
                    try
                        objInputFile = new FileStream(sFileName, FileMode.Open);
                        //objInputStream = new VirtualStream(objInputFile);
                        objOutFile = new FileStream(sFileName.Substring(0, sFileName.LastIndexOf('\\')) + "\\" + Guid.NewGuid().ToString(), FileMode.Create);
                        //objOutStream = new VirtualStream(objOutFile);
                        int nByteRead;
                        while ((nByteRead = objInputFile.ReadByte()) != -1)
                            if (nByteRead != (int)cRemoveChar)
                                objOutFile.WriteByte((byte)nByteRead);
                    finally
                        objInputFile.Close();
                        objOutFile.Close();
                    return sFileName.Substring(0, sFileName.LastIndexOf('\\')) + "\\" + Guid.NewGuid().ToString();
    ==================================
    however when I run the bulk load utility I get the error 
    =======================================
    Bulk load data conversion error (type mismatch or invalid character for the specified codepage) for row 1, column 3 (NumberOfMultipleMatches).
    ==========================================
    the bulk insert statement is as follows
    =========================================
     BULK INSERT Temp  
     FROM '<file name>' WITH  
      FIELDTERMINATOR = ','  
      , KEEPNULLS  
    ==========================================
    Does anybody know what is happening and what needs to be done ?
    PLEASE HELP
    Thanks in advance 
    Vikram

    To load that file with BULK INSERT, use this format file:
    9.0
    4
    1 SQLCHAR 0 0 "\""      0 ""    ""
    2 SQLCHAR 0 0 "\",\""   1 col1  Latin1_General_CI_AS
    3 SQLCHAR 0 0 "\",\""   2 col2  Latin1_General_CI_AS
    4 SQLCHAR 0 0 "\"\r\n"  3 col3  Latin1_General_CI_AS
    Note that the format file defines four fields while the fileonly seems to have three. The format file defines an empty field before the first quote.
    Or, since you already have a .NET program, use a stored procedure with table-valued parameter instead. I have an example of how to do this here:
    http://www.sommarskog.se/arrays-in-sql-2008.html
    Erland Sommarskog, SQL Server MVP, [email protected]

  • SLDCHECK error-Check and maintain the SLD content for the current client

    Hi experts,
           I am trying to configure PI on QAS box and getting this error when I ran SLD check. This is the only warning/error I am getting in YELLOW and the other messages were in green so thinking that is ok.
    =============
       Calling function LCR_GET_OWN_BUSINESS_SYSTEM
       Retrieving data from the SLD server...
      No corresponding business system found for system NWQ      client 001
        => Check and maintain the SLD content for the current client
        Summary: Connection to SLD works technically, but the SLD content may need maintenance
       => Check and maintain the SLD data content
    ==========
    I went through some threads and readiness check document but not able to get it resolved because I am a developer and not sure about exact steps. Please give me if you have any feedback and if there is admin jobs involved I will get BASIS help but it is totally my responsibilty to get the system up and running. Any help would be greatly appreciated.
    Thanks.
    Mithun

    Hi Mithun,
        Let me know if there is any recent changes/Patching/Upgradatiions in your server....
    Perform Cacherefresh both in ABAP and JAVA Stacks..
    For ABAP level cache go to SXI_CACHE -> RUNTIME->START DELTACACHE REFRESH
    >>>>SXI_CACHE -> RUNTIME->COMPLETE CACHE REFRESH
    CPACACHE:
    For complete cache refresh u2013 http://<hostname>:<port>/CPACache/refresh?mode=full
    For delta cache refresh u2013 http://<hostname>:<port>/CPACache/refresh?mode=delta
    Please let me know if this doesnot resolve your issue.
    Cheers!!!!
    Naveen

Maybe you are looking for

  • How can I get my music on iTunes on my new computer?

    I just got a new computer because my old one totally died. All I want to do is get my iTunes on my new computer to have all my music on it, just like it was on my previous computer. I have an first generation iPod Touch, 16GB.

  • One material in two company codes

    How can we maintain one material in two company codes?

  • How to make Lightroom the default photo program

    I don't seem to be able to push Aperture to one side. Nor will lightroom come up for selection when changing the screen display.

  • Can you find the notes of your voice

    I was wondering, if any of you knew if you could see the notes you were singing on garage band. I've searched and searched and I can't find anything. Is there anything?

  • Retrieving command line parameters

    How I can retrieve the command line parameters generated by following JSP? <HTML> <Head> <Title> Reading command line parameters </title> </head> <Body> <P><H1> Press here to try the test command line string</H1></P> </body> </html> Zulfi