Controlling a chemical process with LabVIEW and the SC 2075 board

Hi,
I am a degree student and one of my projects is to control a chemical process using LabVIEW and the SC2075 board. The process variables i must control are temperature, pH and also several motor. Is this viable using the SC 2075 board and if so does anyone know where i can attain information on using the board. Also if anyone has suitable sample vi's that may be of use to me it would be very much appreciated. My email is [email protected]
Kind Regards,
Derek

Hi Derek,
Bellow is a link the the user guide for the 2075.
http://www.ni.com/pdf/manuals/371217a.pdf
You should be able to aquire data from you sensors but you might need some signal conditioning depening on the voltage levels they return.
For sample vi's try going to Help>>Find Examples... within LabVIEW or goto the following link to search our developer exachange.
http://www.ni.com/devzone/dev_exchange/ex_search.htm
For more information about Signal conditioning and Data Aquisition try:
http://zone.ni.com/devzone/devzone.nsf/webcategories/4d58b1b80ec41ef70625683f006e1d6d
I hope this helps
Regards
Jon Bowers
Applications Engineer
NIUK

Similar Messages

  • Controling heating/cooling element with labview and usb 6008 DAQ card

    Greetings All
    I'm looking for a heating/cooling type of element that I can control with labview and my usb-6008 card. Heating/Cooling will just be for clean water and the temperture range will be from 0 C to 100 degree C.
    Thanks
    The heating and cooling elements can be seperate products. Any recommendations

    A simple kettle element will of course be sufficient for upto 100°C
    To get the temperature down you need a cooling system, what springs readily to mind of course is a refrigerator.
    Just a note of warning, water and electricity are dangerous bed fellows.
    On that note perhaps one of those vortex air units would be safer - they blow hot in one direction and cold in the other, nominally to 100°C
    see: -
    http://www.airtxinternational.com/how_vortex_tubes_work.php

  • Troubles with LabVIEW and the SR830 Lock-in Amp.

    i'm quite new to LabVIEW and am trying to use the sr830 instrument drivers
    to control the Lock-in from a computer, but the instrument drivers don't
    seem to want to send or recieve any data. if anyone who is more proficient
    in VI programming couild help me out with this, i would greatly appreciate
    a response. thanks.

    Lackey wrote:
    > i'm quite new to LabVIEW and am trying to use the sr830 instrument drivers
    > to control the Lock-in from a computer, but the instrument drivers don't
    > seem to want to send or recieve any data. if anyone who is more proficient
    > in VI programming couild help me out with this, i would greatly appreciate
    > a response. thanks.
    Are you using the instrument driver downloaded from Nat Inst ??
    If you are this thing looks terrible, but should work.
    You could try building a simple VI to see if all the communication is working
    properly.
    Check to make sure you have the correct GPIB address and that all the cables
    cards etc are properly connected and working.
    Kevin KEnt
    Attachments:
    Kevin.Kent.vcf ‏1 KB

  • How can i work simultaniously with labVIEW and Excel ?

    Hello . I study engineering and need some help with labVIEW, and the connection to microsoft excel.

    Hi
    NI offers an "Report generation toolkit". You get some VI's with this toolkit and so you can directly create your reports from LV.
    Another possibility is the communication through ActiveX. There is a nice link with application notes and LV examples for that:
    http://zone.ni.com/devzone/devzone.nsf/webcategories/C3E56C69D399361E86256AB7006A9149?opendocument&node=DZ53003_US
    Regards,
    Luca

  • How to switch central frequency fastly with labview and USRP?

    Hello everybody,
             Recently I was making a frequency hopping receiver with labview and USRP N210 and SBX. The transmitter works on the 2.4G band, and it changes from one central frequency to another every 65536us. As I think, if I start receiving at the correct time, and  change the central frequency of the USRP every 65536us, I should be able to receive the data.
        But I find that, when usrp switch form one central frequency to a different one, it spends nearly 48ms and when it switch from one frequency to the same one, it only spends 3ms(I test the performance by modifying the niUSRP EX Rx Continuous Async Reconfig on the Fly.vi example). So if I want to follow the hopping sequency, I may can only receive 17ms data because I have to save time for switching central frequency. 
         My problem is that: why usrp changes central frequency so slow,  how can I make the process faster? If I want to follow the hopping sequency, can anybody give me some good advice? Thanks

    There is an attribute "LO Frequency" that you can use to lock down the frequency of the local oscillator.  Then, when you set the "Carrier Frequency" attribute, the difference between the carrier frequency value and the LO frequency value will be realized by frequency shift in the DSP in the FPGA.  Changing this "digital" frequency shift value is much faster, since you don't have to re-tune the local oscillator.
    Let's say you're sweeping from 2.44 GHz to 2.46 GHz.  Set the "LO Frequency" to 2.45 GHz then Commit.  Then, in your loop, program the "Carrier Frequency" attribute from 2.44 GHz to 2.46 GHz.  In the loop, it will only program the digital frequency shift, which will happen much faster.
    Another tip is to use the property node to program only the attributes you want to change, rather than the niUSRP Configure Signal.vi (which sets many at once).
    For more details, see the "Configuration:Advanced:LO Frequency Property" in the NI-USRP Help, and look at this example:
    <LabVIEW dir>\examples\instr\niUSRP\niUSRP EX Fine-Tune LO Frequency.vi

  • How to access SPECIFIC camera attributes tree (camera controls) located in MAX with Labview?

    How to access specific camera attributes tree (camera controls) located in MAX with Labview?
    I want to be able to access frame, trigger and grab properties. Does anyone know?
    Thanks.
    /Peter

    Please see this related thread http://forums.ni.com/t5/LabVIEW/IMAQdr-Property-Node/m-p/1642950/highlight/false#M590168
    Matt
    Product Owner - NI Community
    National Instruments

  • Face and Eye Tracking with LabView and Vision

    Hey all,
    For my senior project I am trying to perform face tracking and eye tracking by using LabView and the Vision Development Module. Unfortunately I am new to LV and I'm drowning in a sea of links and tutorials so I was wondering if anyone here that has had experience performing similar tasks would be willing to help and point me in the right direction or provide examples. I bought two Logitech c525 webcams and hooked them up to my pc running LabView and Vision 2011. I was able to see images captured but that's as far as I've gotten with the tools. Any tips?
    Thanks,
    Alex.

    have a look at http://sine.ni.com/cs/app/doc/p/id/cs-14116 and http://forums.ni.com/t5/Machine-Vision/how-to-trac​k-face-and-allocate-lips-in-face-using-labview/td-​...
    This thread would also be more suited to the Machine Vision section.

  • Create a CR for multiple processing with me as the current processor

    Hi
    How to create a change request for multiple processing with myself as the current processor.
    I have created a change request for multiple processing and the ystem throws me the error that "There are no suitable change requests"
    Display help shows the below
    For the upload you need a change request that has the status Considered
    and Approved or To Be Revised and ideally has a type that does
    not have the property Object List Is Binding. If the
    change request does have this property, all the entities that are uploaded must
    already be assigned to this object list.
    Please can someoen guide me on how to fix this.
    I found few threads related to this but cudint understand on how to assign a status to CR
    Thanks,
    Sharma

    Hi Prateek,
    Please can anyone give any pointers on how to set the status of change request (for multiple processing):-
    For assigning the statuses to the change request:-
    Go to t code:- MDGIMG->General settings>Process Modeling>Change Request>Edit status of change request.
    the path you mentioned is to create and edit the existing Change request statuses, what I am looking for is when I create a CR for Multi record processing and try to upload a file I get the error "There are no suitable change requests". and when I check the Status of the change request I created I see that the status is Changes to be executed (Set automatically).
    how can i set myself as the processor.
    tcode: MDGIMG->General settings>Process Modeling>Change Request>Create Change request type. Ucheck the single object checkbox and assign your userid for that CR step.
    Single object is already Unchecked  and I am using BRF+ so when I am the processor First approver is say X, I am not sure if we have any place where we can set ourselves as the user. Please let me know if I missed sumting
    Thanks
    Hi Shephalika,
    Yes I am trying to upload a file and Single object is Unchecked in the Change request type.
    Thanks,
    Sharma

  • Mountain Lion fails to install saying it cannot create the recovery; I had a similar problem with Lion and the Apple Store that helped me resolve it gave me an installable version of Mountain Lion on a flash drive for my inconvenience....

    Mountain Lion fails to install saying it cannot create the recovery; I had a similar problem with Lion and the Apple Store that helped me resolve it gave me an installable version of Mountain Lion on a flash drive for my inconvenience....is there some trick I am missing or do I need to make an appointment with a genius...

    I have the MacIntosh volume and the Boot Camp partition only.  I know that when I installed Lion, I had to go through a whole back-up and recovery of Windows and then re-format the drive. 
    The tech at the Apple Store had a previous life as a MSCE and was very helpful.  I believe he even said that I should not have htis problem with Mountain Lion which is why they gave me the flash with it onboard.  I was in the process of starting a new job when I went to Lion, so I have waited to do this next and probably last upgrade to this old MBP since I doubt Apple will support this MBP in Maverick. 
    I do not have another installation, so that is not an option.  I will try to create an external, I have plenty of hard drives around and see if I can get it done that way.  It might take me a week or two to get back to it, but I will comment back upon completion of that effort.  Thanks for your help....Dave Iverson

  • I am having troubles with 3 things: scrolling with my laptop mouse, controlling my laptops volume with F9 and F10 keys, and I can not copy and paste images.

    I am having troubles with 3 things: scrolling with my laptop mouse, controlling my laptops volume with F9 and F10 keys, and I can not copy and paste images.

    Hello,
    Try disabling graphics hardware acceleration. Since this feature was added to Firefox, it has gradually improved, but there still are a few glitches.
    You might need to restart Firefox in order for this to take effect, so save all work first (e.g., mail you are composing, online documents you're editing, etc.).
    Then perform these steps:
    *Click the orange Firefox button at the top left, then select the "Options" button, or, if there is no Firefox button at the top, go to Tools > Options.
    *In the Firefox options window click the ''Advanced'' tab, then select "General".
    *In the settings list, you should find the ''Use hardware acceleration when available'' checkbox. Uncheck this checkbox.
    *Now, restart Firefox and see if the problems persist.
    Additionally, please check for updates for your graphics driver by following the steps mentioned in the following Knowledge base articles:
    [[Troubleshoot extensions, themes and hardware acceleration issues to solve common Firefox problems]]
    [[Upgrade your graphics drivers to use hardware acceleration and WebGL]]
    volume controls issues are windows, not firefox.
    How your copy and paste your image? from where to where

  • Command a ventilator with USB6251 and The Daq Signal Accessory

    Hello,
    I would like to make a school project using Labview and the USB6251 connected  to the Daq Signal Accessory Board.
    The Labview program must read continuously the temperature from the temperature sensor (AI channel 4, internally connected) from the Daq Signal Accessory Board. When the temperature reaches an established value, then a led on the front pannel must be turned on and an output singal from the Daq must start a ventilator connected to the Daq which cools down the sensor and then stops.
    Would it be possible to do something like this? Even if I generate a square signal and the ventilator runs only on the high state of the signal. The ventilator requires at least 120 mV DC current. I am afraid that if I take such current from the Daq I might damage the device.
    Thank you.
    Solved!
    Go to Solution.

    I guess you mean 120 mA DC current . If you look at your daq board spec you will find that the max current are far bellow 120 mA. This is true for both analog out and digital out. Take a look at this site it may help out some. http://www.me.umn.edu/courses/me2011/robot/technotes/motorcontrol/motorcontrol.html cool site. If you want speed control you have two options PWM or regulating the motor voltage.
    Good luck
    Besides which, my opinion is that Express VIs Carthage must be destroyed deleted
    (Sorry no Labview "brag list" so far)

  • Anyone got experience with LabView and JTAG ?

    Anyone got experience with LabView and JTAG ?
    Especially in system programming of Altera and FLASH

    Yes, I've actually driven JTAG using DIO, but this was a project in itself.
    I guess you're just wanting to get the job done! I'm currently evaluating
    gear to do the same job myself, in addition to interconnect testing. I've
    been looking at JTAG Technologies equipment. They do PCI/PXI cards and the
    SW, with a LabVIEW interface.
    They're at:
    www.jtag.com
    You'll need to be sitting down when you get their quote though - their development
    system costs about the same as a decent car!
    Cheers
    -Sean.
    [email protected] wrote:
    >Anyone got experience with LabView and JTAG ? >Especially in system programming
    of Altera and FLASH

  • Will internet recovery work on my mid 2010 MBP with yosemite and the firmare internet recovoery update designed for OS lion

    will internet recovery work on my mid 2010 MBP with yosemite and the firmare internet recovery update designed for OS lion

    Yes, it does. The point is can your computer use full Internet Recovery with the firmware update or not. If not then you have to begin with the Snow Leopard DVD that came with your computer and do an Erase and Install.
    Clean Install of Snow Leopard
    Be sure to make a backup first because the following procedure will erase
    the drive and everything on it.
         1. Boot the computer using the Snow Leopard Installer Disc or the Disc 1 that came
             with your computer.  Insert the disc into the optical drive and restart the computer.
             After the chime press and hold down the  "C" key.  Release the key when you see
             a small spinning gear appear below the dark gray Apple logo.
         2. After the installer loads select your language and click on the Continue
             button. When the menu bar appears select Disk Utility from the Utilities menu.
             After DU loads select the hard drive entry from the left side list (mfgr.'s ID and drive
             size.)  Click on the Partition tab in the DU main window.  Set the number of
             partitions to one (1) from the Partitions drop down menu, click on Options button
             and select GUID, click on OK, then set the format type to MacOS Extended
             (Journaled, if supported), then click on the Apply button.
         3. When the formatting has completed quit DU and return to the installer.  Proceed
             with the OS X installation and follow the directions included with the installer.
         4. When the installation has completed your computer will Restart into the Setup
             Assistant. Be sure you configure your initial admin account with the exact same
             username and password that you used on your old drive. After you finish Setup
             Assistant will complete the installation after which you will be running a fresh
             install of OS X.  You can now begin the update process by opening Software
             Update and installing all recommended updates to bring your installation current.
    Download and install Mac OS X 10.6.8 Update Combo v1.1.
    However, if you can use full Internet Recovery:
    Install Yosemite, Mavericks, Lion/Mountain Lion Using Internet Recovery
    Be sure you backup your files to an external drive or second internal drive because the following procedure will remove everything from the hard drive.
    Boot to the Internet Recovery HD:
    Restart the computer and after the chime press and hold down the COMMAND-OPTION- R keys until a globe appears on the screen. Wait patiently - 15-20 minutes - until the Recovery main menu appears.
    Partition and Format the hard drive:
    Select Disk Utility from the main menu and click on the Continue button.
    After DU loads select your newly installed hard drive (this is the entry with the mfgr.'s ID and size) from the left side list. Click on the Partition tab in the DU main window.
    Under the Volume Scheme heading set the number of partitions from the drop down menu to one. Click on the Options button, set the partition scheme to GUID then click on the OK button. Set the format type to Mac OS Extended (Journaled.) Click on the Partition button and wait until the process has completed. Quit DU and return to the main menu.
    Reinstall Lion/Mountain Lion. Mavericks: Select Reinstall Lion/Mountain Lion, Mavericks and click on the Install button. Be sure to select the correct drive to use if you have more than one.
    Note: You will need an active Internet connection. I suggest using Ethernet if possible because it is three times faster than wireless.
    This should restore the version of OS X originally pre-installed on the computer.

  • TS3694 i factory unlock my iphone 3gs and was on ios 6.1.2 and updatednit to 6.1.3 with itunes and the phone got lock again at activation screen. i try downgrading to 4.1 with baseband 5.13.04 and want to upgrade back to 6.1.2. pls help me

    i factory unlock my iphone 3gs and was on ios 6.1.2 and updatednit to 6.1.3 with itunes and the phone got lock again at activation screen. i try downgrading to 4.1 with baseband 5.13.04 and want to upgrade back to 6.1.2. pls help me

    Sorry, downgrading the iOS is not supported by Apple, thus there is no official way to do so. Your phone was re-locked to the carrier it was originally locked to because you hacked it to unlock it. Apple's servers detected such & re-locked your phone. You need to contact the carrier your phone is locked to if you want to get it officially unlocked.

  • How do i set up my apple id with itunes and the appstore?

    How do i set up my apple id with itunes and the appstore?

    iTunes 10 for Mac: Set up an Apple ID account for use in the iTunes Store
    http://support.apple.com/kb/PH1726

Maybe you are looking for

  • Sender mail adapter - attachment name

    Hi there We have configured a sender email adapter to receive text/csv attachments and save them to a file system. What we are having a problem with is reading the attachment name. So we are using Dynamis Configuration to create the file name using t

  • Maximum size of a package in oracle 10g ?

    Hi, I am using Oracle 10g, version-10.1.0.4.2 and OS- Windows XP. What should be the maximum size of a package in oracle 10g ? Thank u....! Ravi

  • How to create an instance of a protected class outside the enclosing packag

    Hi all, I have a piece of code like this: package test; public class A { protected class B { } How to create an instance of B outside the package test ? Could you please give me an example ? Thanks Ha Chau

  • Video, when played on iPod, doesn't contain any audio.

    So, I converted an episode of an anime from .mkv to .mp4, since that is a compatible format for videos on the iPod Touch (using 4th gen). I exported the episode to my iPod touch using CopyTrans Manager, since iTunes doesn't particularly like me doing

  • How to access data from WPBP(Work center) in t-code PC_PAYRESULT ?

    Hi All, I am working on HR module and need to get the values of  table WPBP(Work Center) from PC_PAYRESULT .I need the no. of working days calculated here . So , is there any functional module to get the values o WPBP? Edited by: VimalSharma on Aug 1