Create A New Monitoring Profile In Grid Control

Hi All,
We need to set up a monitoring user in grid control to monitor only a few limited metrics i.e FRA area filled , Shared Pool usage, Archiver hung,cpu usage & memory usage..
This account would be provided to a monitoring team to view only these metrics and of course wont have rights to modify anything in the database so only read only access...
I managed to create a read only account from Setup----Administrators---Create...
So doing the above i have created the read only user from the appropriate options, now my only question is that i do not want to give read only access for any other metrics apart from the ones i mentioned above..
Is it possible to set only the above five metrics.
Thanks...

Hi;
For your issue i suggest close your thread here as changing thread status to answered and move your issue to Forum Home » Enterprise Manager » Enterprise Manager Grid Control
Regard
Helios

Similar Messages

  • Creating a new monitor profile

    Does anyone know how to Create a new monitor profile...Running Windows 7 with Elemnts 9 and I cant find a Adobe Gamma Wizard on my PC.

    Adobe Gamma has been long discontinued, because it was never meant to work with anything but the old fashioned CRT monitors (the ones like  tube television sets).
    You may have some kind of utility in your video driver, which is better than nothing, but the best way to calibrate a monitor is with a hardware device. They're not nearly as expensive as they used to be--check out the Huey or the colormunki, for example.

  • Create a new monitor profile?

    I'm using a big screen iMac at work to connect to my Mac Pro at home (With a smaller monitor). Can I create a new monitor profile closer to the iMac's monitor size?

    Adobe Gamma has been long discontinued, because it was never meant to work with anything but the old fashioned CRT monitors (the ones like  tube television sets).
    You may have some kind of utility in your video driver, which is better than nothing, but the best way to calibrate a monitor is with a hardware device. They're not nearly as expensive as they used to be--check out the Huey or the colormunki, for example.

  • Cannot create a new monitor profile

    Just got new 27" imac.
    Everytime I try to calibrate monitor I get,
    error, could not create new profile.
    Is this some issue? thanks.

    make a back up if you dont already have one, read those carefully and go down the list. the second option should sort it, and what profiles are you talking about? connectivity or user profile for phone, text, email stuff? 
     1. *#7780# - Restore factory settings - resets all the settings to the default ( you will not lose any data)
    Make sure you back up your data as you will lose all of it when you perform option 2 or 3 on this list. The default code for ALL operations listed here is 12345
    2. *#7370# - Reformat your phone (out of the box, tho keep in mind that most newer nokia phones at least n series, e series and s60 based phones have udp - user data preservation so not ALL data may be lost. still it is a good idea to always do a back up of your stuff.)
    3. This you perform as a last resort. Nothing else is working.If the phone is not showing any activity, proceed with hard formatting , turn off your phone, hold the following buttons while pressing the power button. (the default code is 12345)
    hard reset - hold the following buttons *, 3 (number button) and talk/green key. turn on the phone and do not release those buttons until you see the Nokia boot up screen. once you feel the phone power up you can let go off the power button while still holding all three buttons ( for Nokia 5800XM - use the following buttons to do a hard reset, GREEN/RED/CAMERA keys pressed all at once on power up. this will only work on 5800's that have firmware version 20... and up. )
    If these codes are not working the only thing for you to do is contact your Nokia Care Center/Service for assistance. 
    Message Edited by radical24 on 27-Aug-2009 09:59 AM
    You know what I love about you the most, the fact that you are not me ! In love with technology and all that it can offer. Join me in discovery....

  • Error creating a new user profile service application: The specified database is not a valid synchronization database

    When trying to create a new user profile service application on a new SharePoint install I get the following error:
    "The specified database is not a valid synchronization database"
    The installation then fails and does not create the third database. 
    I found some threads with similar problems but it involved upgrading an existing db.  In this case we want to create a new one.  Here is the relevant ULS log info:
    Starting schema provisioning of SynchronizationDatabase 'SP15_TEST_ENT_SyncDB'
    Provisioning the SP15_TEST_ENT_SyncDB database with the script at C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\15\Template\SQL\SPS\drop_procs.sql.
    Provisioning the SP15_TEST_ENT_SyncDB database with a script stream.
    Ensuring that the SP15_TEST_ENT_SyncDB database exists . . .
    The SP15_TEST_ENT_SyncDB database does not exist. 
    It will now be created.
    Setting the AutoClose option to False on the database SP15_TEST_ENT_SyncDB.
    Setting the ArithAbort option to True on the database SP15_TEST_ENT_SyncDB.
    Setting the TruncLogOnChkpt option to True on the database SP15_TEST_ENT_SyncDB.
    Starting schema evaluation of existing SynchronizationDatabase 'SP15_TEST_ENT_SyncDB'
    Validate Database: validating sync database
    Validate Database: validation failed: Error code -2
    Application error when access /_admin/NewProfileServiceApplicationSettings.aspx, Error=The specified database is not a valid synchronization database 
     at Microsoft.Office.Server.Administration.SynchronizationDatabase.Provision()   
     at Microsoft.Office.Server.Administration.UserProfileApplication.Provision()   
     at Microsoft.SharePoint.Portal.UserProfiles.AdminUI.NewProfileServiceSettingsPage.DoCreateApplication()   
     at Microsoft.SharePoint.Portal.UserProfiles.AdminUI.NewProfileServiceSettingsPage.OnOkButtonClick(Object sender, EventArgs e)   
     at System.EventHandler.Invoke(Object sender, EventArgs e)   
     at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument)   
     at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)
    Microsoft.SharePoint.Administration.SPDatabaseException: The specified database is not a valid synchronization database  
     at Microsoft.Office.Server.Administration.SynchronizationDatabase.Provision()   
     at Microsoft.Office.Server.Administration.UserProfileApplication.Provision()   
     at Microsoft.SharePoint.Portal.UserProfiles.AdminUI.NewProfileServiceSettingsPage.DoCreateApplication()   
     at Microsoft.SharePoint.Portal.UserProfiles.AdminUI.NewProfileServiceSettingsPage.OnOkButtonClick(Object sender, EventArgs e)   
     at System.EventHandler.Invoke(Object sender, EventArgs e)   
     at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument)   
     at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)
    Getting Error Message for Exception System.Web.HttpUnhandledException (0x80004005): Exception of type 'System.Web.HttpUnhandledException' was thrown. ---> Microsoft.SharePoint.Administration.SPDatabaseException:
    The specified database is not a valid synchronization database   
     at Microsoft.Office.Server.Administration.SynchronizationDatabase.Provision()   
     at Microsoft.Office.Server.Administration.UserProfileApplication.Provision()   
     at Microsoft.SharePoint.Portal.UserProfiles.AdminUI.NewProfileServiceSettingsPage.DoCreateApplication()   
     at Microsoft.SharePoint.Portal.UserProfiles.AdminUI.NewProfileServiceSettingsPage.OnOkButtonClick(Object sender, EventArgs e)   
     at System.EventHandler.Invoke(Object sender, EventArgs e)   
     at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument)   
     at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)   
     at System.Web.UI.Page.HandleError(Exception e)   
     at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)   
     at System.Web.UI.Page.ProcessRequest(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)   
     at System.Web.UI.Page.ProcessRequest()   
     at System.Web.UI.Page.ProcessRequest(HttpContext context)   
     at System.Web.HttpApplication.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute()   
     at System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously)
    I Tried to create another one under a different name (databases also) and I get the same error. 
    The SharePoint instance has the march mandatory update installed.  The sql instance we are using is an existing SQL cluster for other SharePoint poc's. 
    Has anybody seen this issue before? 

    I had the same problem and could not figure out what was wrong for the longest time.  I then had the idea to check in the model system database to see if there were any extra custom tables in that database.  Any tables that are in the model database
    are put into any new database when it is created.  I had some custom tables in the model database so I deleted the custom tables in the model database and deleted the failed user profile service application and its databases and then tried to recreate
    the user profile service application again and it worked with no errors

  • Creating a new application profile

    Hi Hyperion Gurus,
    Need your advice on an issue we are facing now:
    In our current application (HFM 11.1.2.2. EPMA), we have created our application profile with only English as the language. We have 3 applications residing on our current profile.
    We now have a requirement as to include Japanese as a language. I am aware that I can not make changes to the alias dimension in the  existing application. This means that we will have to create a new application profile.
    My question is: What will happen to the existing shared library that we use for our current applications? When I create a new application will it impact the old ones?
    Any thoughts and ideas are greatly appreciated!
    Thanks,
    Steffi.

    Hi Thanos,
    so I did create a new application profile and included the languages I needed. And when I created the application, the Alias dimension is blank.
    Here are the steps that I followed:
    1. Create a new application profile from the desktop client.
    2. Opened work space and created New application from Administer > Consolidation Administration.
    3. Registered the application to Shared Services.
    4. Transformed the classic app to EPMA in order to use the Shared library
    Not sure what I am missing. I have attached a screenshot of the dimension library from my new application.

  • Creating a New Document Profile CS5

    I have created a New Document Profile that I want to use as a base when starting Ilustrator work. I  cleared pallettes colors, brushes, symbols etc and created 3 new common layers etc. When I select my file from the New Document Profiles pull down menu the Layers pallette opens with only a blank Layer1 .The work on my custom Layers that I would like as masters is gone.

    Where did you save the new file?
    Looks like you're right. Seems only way is to Save the file as a Template file and use New from template from the file menu.

  • BUG: Access Connect Abort, when I create a new network profile.

    Where can I report bugs?
    My system is windows xp sp2 on X60.
    I have been using AC-4.42(Access Connection) for a long time. And before,  there is no problem when I added new network profile into it.
    But yesterday, I wanted to add a new profile into it. I opened the "create profile" window and input the name of the new profile (I have two network adapters, wired and wireless. So by default, the both are selected. And I left the default selection unchanged.), then "Next". The 2nd window is about wireless config, I configured everything, then go on "Next", at this moment, an error occured and AC aborted with four error windows. The titles of those windows are "ACMainGUI.exe error" and "ACMainGUIWnd: ACMainGUI.exe".
    Then I did it again, I opened the "create profile" window, and this time, in this (1st) window, I changed the selection of network adapter, besides inputing the name of the new profile. I only selected the wired adapter, and then "Next". Sadly, this time the 2nd(next) window did not appear(pop up) at all. Instead, those four error windows poped up one by one.  AC aborted again.
    I repeated the above operations many times, and everytime, AC aborted.
    So I went to the online "support and download" to look for some updates about AC. And I found AC-4.52 with luck. After downloading and installing, unfortunately the problem still exists. AC-4.52 still aborts when I create a new network profile.
    So now, what to do. I have no ways. I am expecting the developers could note this problem and fix it and give me a newer update as soon as possible.
    Sigh...

    I have exactly the same issue. Next to the actions mentioned by ixbm I have also fully uninstalled and reinstalled the AC-4.52, but this didn't help.
    Any idea on how to solve, installing older version?
    regards,
    Bart

  • How do I create a new lens profile?

    How do I creat a new lens profile for a Canon EF135mm f/2 and EF200 f/2.8 in lightroom 3.3?

    Hi Simon,
    Thanks for your reply.   I figured it out, I  downloaded the new version of Raw 6.3 and now I have the lens profile and others  such as crop constraint and
    chromatic abrerrations.  I was looking for these items in Photoshop Raw
    Thanks,
    Aideen
    If I understand you correctly, you found and downloaded a lens profile that matches your camera and lens, and you don't see the profile in LR?
    1. Make sure that you relaunch LR after you downloaded the lens profiles.
    2. The type of lens profiles (raw or non-raw) matches your image type (raw or non-raw). Namely you can only apply raw lens profiles to raw image files and vice versa for the non-raw profiles.
    -Simon
    >

  • Creating a New Forecasting profile for MRP

    Hi there,
    Please can somebody let me know how do I create a new Forecasting profile for MRP. 
    I want to see this in table MRPR once created.  (field PROPR).
    Kind Regards,

    Dear marelizen
    Use transactio code MP80.
    Creating a Profile  
    The information contained in this info object is relevant to the material master for industry and to the article master for retail. Retail customers are requested to substitute:
      article for material
      requirements planning for material requirements planning or MRP
    1. In the Material Master menu, choose Profile ® MRP profile or Forecast profile ® Create.
    The initial screen appears.
    2. Enter the name you want to give the profile.
    If you want to use an existing profile as a reference, enter its name under Copy from so that the system can copy its values to the new profile.
    3. Choose Selection screen.
    The selection screen appears. It shows all the fields that can be copied to the MRP or Forecasting screen in the material master record.
    4. Enter a profile description and select the fields you want the profile to contain, specifying whether each field is to be copied to the material master record as a fixed value or as a default value.
    It is not possible to select Fixed lot size and Maximum stock level in a single MRP profile. However, if you select Maximum stock level, you must also select Lot size (materials planning).5. Choose Data screen.
    MRP profile data is spread over two screens. To switch from one screen to the other, choose Data screen 1 or Data screen 2.
    When you access the data screen from the selection screen, the system checks whether the fields selected are allowed to appear in the same profile.
    The data screen appears, containing only the fields you selected on the selection screen. The fixed values and default values are displayed in different colors. All fixed values are required fields except where the field can also be left blank.
    If, in the forecast profile, you enter N or 0 as the forecast model, no forecast is made.
    Like forecast model N, if you enter forecast model 0 when maintaining a forecast profile, you will be unable to maintain any other field in the profile.
    Unlike forecast model N, forecast model 0 deletes any existing forecast values when you change the material. This ensures that these values are no longer included in materials planning.
    6. Enter the corresponding values and save the profile.
    If the system detects inconsistencies or errors, it asks you to change the fields selected on the selection screen and/or to correct the values. Otherwise, the initial screen appears, where you can begin to create another profile.
    warm regards
    Ramakrishna

  • How to monitor ODI in Grid Control

    Hello
    We are using Grid Control 11.1.0.1.0 and ODI 11.1.1.5.0.
    We were previously using a grep command on the server that ODI was running from to monitor if it was up or not.
    Since the (OEM) upgrade we have lost this metric and would like to take a more elegant approach to monitoring the state of ODI.
    (We didn't install ODI as part of a WebLogic Server install, it is stand alone and therefore the plugins or usual way to monitor are not relevant to us.)
    Is there a way I can have Grid (via a UDM for instance) go into the database and query for a process?
    If the process is found then no alert is sent. This also means that we will only have to blackout the database during cold backups instead of the whole server.
    Hopefully this makes sense and hopefully someone can give me a few hints / tips on how to achieve this?
    Thanks.

    You can find info about the backups in sysman.mgmt$ha_backup. But only one entry per database can be seen. So only for the latest rman job you will find info here.
    You could also start using a rman catalog that will contain all backup info (example http://oracleinstall.wordpress.com/2011/06/03/oracle-11g-rman-catalog-setup/). You can create reports/queries on the rman repository to get the info you need.
    Or even better: create a rman repository and schedule the rman jobs using Grid/Cloud Control.
    Eric

  • Add a New line to ALV Grid control

    Hi experts,
       My requirement is after filling ALV grid, user will select a + button from the menu, I need to add a new line next to the selected ALV line (Like in a table control).  Does it posible to do this? If can any body tell me how I can do this.
    Regards,
    Venkat.

    Hi Venkat...
    I have tried this and it worked...
    Just copy paste this program...
    Note : U will have to create a new PF status for this... and give the Function code as given in my program... then only it will work...
    *& Report  Z_ALV_TRAINING_LIST_EVENTS
    REPORT  Z_ALV_TRAINING_LIST_EVENTS.
    Tables  *************
    TABLES : T001.
    Type Pools Used  **********
    TYPE-POOLS : SLIS.
    Types Declared  **********
    Internal Tables Declare  ************
    DATA : IT_company    TYPE STANDARD TABLE OF T001 INITIAL SIZE 0 WITH HEADER LINE,
           IT_FIELD_CAT  TYPE SLIS_T_FIELDCAT_ALV,
           it_alv_event  type SLIS_T_EVENT.
    Select Data  ***********
    start-of-selection.
    SELECT * FROM T001 INTO TABLE IT_company.
    Make Field Catalog  ******
    PERFORM MAKE_FIELD_CATALOG.
    get evente  *****
    perform get_alv_events.
    Display ALV  *********
    end-of-selection.
    PERFORM DISPLAY_ALV_LIST.
    *&      Form  make_field_catalog
          text
    -->  p1        text
    <--  p2        text
    FORM MAKE_FIELD_CATALOG .
    CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE'
      EXPORTING
      I_PROGRAM_NAME               =
      I_INTERNAL_TABNAME           =
       I_STRUCTURE_NAME             = 'T001'
      I_CLIENT_NEVER_DISPLAY       = 'X'
      I_INCLNAME                   =
      I_BYPASSING_BUFFER           =
      I_BUFFER_ACTIVE              =
      CHANGING
        CT_FIELDCAT                  = it_field_cat
    EXCEPTIONS
      INCONSISTENT_INTERFACE       = 1
      PROGRAM_ERROR                = 2
      OTHERS                       = 3
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    ENDFORM.                    " make_field_catalog
    *&      Form  display_alv_list
          text
    -->  p1        text
    <--  p2        text
    FORM DISPLAY_ALV_LIST .
    CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
    EXPORTING
      I_INTERFACE_CHECK              = ' '
      I_BYPASSING_BUFFER             =
      I_BUFFER_ACTIVE                = ' '
       I_CALLBACK_PROGRAM             = sy-repid
        I_CALLBACK_PF_STATUS_SET       = 'SET_MY_PF_STATUS'
      I_CALLBACK_USER_COMMAND        = ' '
      I_STRUCTURE_NAME               =
      IS_LAYOUT                      = fl_layout
       IT_FIELDCAT                    = it_field_cat[]
      IT_EXCLUDING                   =
      IT_SPECIAL_GROUPS              =
      IT_SORT                        =
      IT_FILTER                      =
      IS_SEL_HIDE                    =
      I_DEFAULT                      = 'X'
       I_SAVE                         = 'X'
      IS_VARIANT                     = '/TEST_VV'
        IT_EVENTS                      = it_alv_event
      IT_EVENT_EXIT                  =
      IS_PRINT                       =
      IS_REPREP_ID                   =
      I_SCREEN_START_COLUMN          = 0
      I_SCREEN_START_LINE            = 0
      I_SCREEN_END_COLUMN            = 0
      I_SCREEN_END_LINE              = 0
      IR_SALV_LIST_ADAPTER           =
      IT_EXCEPT_QINFO                =
      I_SUPPRESS_EMPTY_DATA          = ABAP_FALSE
    IMPORTING
      E_EXIT_CAUSED_BY_CALLER        =
      ES_EXIT_CAUSED_BY_USER         =
      TABLES
        T_OUTTAB                       = it_company
    EXCEPTIONS
      PROGRAM_ERROR                  = 1
      OTHERS                         = 2
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    ENDFORM.                    " display_alv_list
    *&      Form  get_alv_events
          text
    -->  p1        text
    <--  p2        text
    FORM get_alv_events .
    data : wa type slis_alv_event.
      wa-name = 'USER_COMMAND'.
      wa-form = 'SUB_MY_PF_EVENT'.
      append wa to it_alv_event.
    ENDFORM.                    " get_alv_events
    *&      Form  sub_my_pf_event
          text
    -->  p1        text
    <--  p2        text
    FORM sub_my_pf_event using p_comm type sy-ucomm p_sEL_FIELD TYPE SLIS_SELFIELD.
      data : wa type t001.
      case p_comm.
        when 'BACK'.
          leave program.
        when 'EXIT'.
          leave program.
        when 'NEW'.
          clear wa.
          insert wa into it_company[] index p_sel_field-tabindex.
          PERFORM DISPLAY_ALV_LIST.
      endcase.
    ENDFORM.                    " sub_my_pf_event
    *&      Form  SET_MY_PF_STATUS
          text
    -->  p1        text
    <--  p2        text
    FORM SET_MY_PF_STATUS USING    p_rt_extab TYPE slis_t_extab.
    SET PF-STATUS 'ZALV_STATUS'.
    ENDFORM.                    " SET_MY_PF_STATUS
    Plz award points if this was helpful....

  • Created a new user profile but it does not show on Login screen or fast sw

    I have created a new profile that I want to be an admin profile. The creation of the profile went ok. I can see and edit the profile. When I reboot or logout, the login menu only show the inital profile that I set up when I got the system. The new user id also does not show up when I go to my fast switch menu.
    My original user id is set to automatically logon when the system is started. I did try and set the new userid to be the one that started automatically on bootup and then both profiles appeared in the startup menu and fast switching menu.
    If I switch back to having my original user id be the id that automatically logs in on bootup then the new user id disappears again from the login and fast switch menus. I really don't want to startup on my admin id.
    Any ideas?

    No not yet. I am still researching the problem. I was hoping someone in the discussion forum could help. Let me know if you find a resolution.

  • How to add a new server to the grid control

    Hi ,
    OEM 10g grid control has already bee installed n our site . But I don't know how a add /configure a new sever / database into that . Do I need to install the agent software on the destination machine OR is there any way to add the new sever from the 10g grid control itself ... Please help me out . You can also revert me back on my id [email protected]
    redgs
    RAHUL

    thnx for replying .
    Could you please tell me the patch number that I need to download for OEM grid control 10.2.0.3 . Actually I searched for lot of docs . But didn't found doc regarding installation of oem agent and agent PATCH number .
    So , Please revert back with necessary Patch number and all the steps that I need to be follow . Thanx in advance
    regds
    RAHUL

  • I created a new account/profile on my Mac OS X (10.4.11) and tried to download Firefox, which I am already using on my existing account/profile, and was told that my system doesn't support Firefox; what's this all about?

    I would like to be able to use Firefox on the new account/profile I have created and don't know why my system will support it on this account/profile but not the new one.

    Firefox 4 requires at least OS X 10.5 and an Intel Mac. There is a third party version of Firefox 4 that runs on OS X 10.4/10.5 and PPC Macs, for details see http://www.floodgap.com/software/tenfourfox
    If you prefer, you can get the latest version of Firefox 3.6 from http://www.mozilla.com/en-US/firefox/all-older.html
    Mozilla are working to prevent Mac users with non-compatible systems from getting the notification about Firefox 4, and also not displaying the "Download Firefox 4" button on http://www.mozilla.com

Maybe you are looking for