Crystal Reports 2011 not working in windows 2008 server CITRIX
Hi All,
We are using Crystal reports 2011 in windows 2008 server which is CITRIX farm., having crystal reports 2011 runtime in it..
We are using .net applicationton to run the reports.
The crystal reports parameter popup is getting opened. But the calendar icon is not fuctioning ..clicking on the calendar control no pop up appears. no error too..
OK button is not responding. Cancel button too.
Can you please help us why we are facing this issue in CITRIX only. When we are using the same version in desktop, Crystal report is working fine.
Please feel free to ask if required any more details about my problem.
Regards,
Venkat.K
Ido's idea is excellent, only addition I'd like to make is the following:
You are trying to run a .NET app. However, CR 2011 does not install any SDKs. So, the directory specified by Ido is not correct. Assuming that by CR 2011 you actually mean "SAP Crystal Reports, Developer Version for Visual Studio .NET", then the directory would be:
C:\Program Files (x86)\SAP BusinessObjects\Crystal Reports for .NET Framework 4.0\Common\Crystal Reports 2011\crystalreportviewers\prompting
If that does not help, use Process Monitor and see what the logs tell you (look for Access Denied messages).
- Ludek
Senior Support Engineer AGS Product Support, Global Support Center Canada
Follow us on Twitter
Similar Messages
-
Automate the database and forms / reports services to start on windows 2008 server R2 startup
Dear memebers,
I want to automate the database and forms / reports services to start on windows 2008 server R2 startup. whats the possibilities and which method is the best?
Regards:Hi,
type services.msc at run
then check for Oracle Services--> Right Click-->Properties-->Startup type-->start automatic
HTH -
Dear Team
i need solution from Microsoft for the issue;
My infrastructure
- Windows Server 2008 R2 (Role - AD and Terminal Service)- Updated
- Client Machine running with windows 7 pro (Updated)
- Client Using RDP Client to connect Windows 2008 Terminal Session
- All are working fine, but Redirect Printing is not working (Through Windows 7 Pro) ... (HP Laser Jet 1020 plus - attached in Client PC)
- it is working fine from Windows XP
- i was done All terminal setting in both end, also try RDP Login with Administrator User, but issue is not resolve;
What Microsoft can say about the issue;
Thanks & Regards,
VIMAL PRAJAPATI | 09824111686Have you checked the Print Service log in event viewer?
Here's How.
I have the Microsoft XPS driver on my clients, so I use that fact to my advantage below.
Click Start Button/Administrative Tools/Remote Desktop Services/Remote Desktop Services Manager on the RDSH server
Click the Sessions tab. PC’s are listed Under Client Name by their computer name. Take Note of the corresponding
ID. We will use this to locate the Printer information in the Event Log.
In the Event Log open Application and Services Logs/Microsoft/Windows/Print Service/Admin/ and Find the Event ID 823 entry that has the corresponding ID from the sessions tab you previously noted.
This Event Log Entry is created at Logon and you can only get the session ID when they are logged in.
This tells you what client printer was mapped for the client. The name that appears is the name of the Printer that was set on the client when the printer was installed.
See if you see any errors here.
If you see Event Id 823 with the following message “The default printer was changed to Microsoft XPS Document Writer,winspool,Ne00:. See the event user data for context information.” Twice in a row with no other messages in between, and the first occurs
at the time the user logged in, then their printer was not properly redirected.
You see the Microsoft XPS driver mapped for each session prior to Easy Print redirecting the client machine’s Default Printer.
Since your printer is the HP 1020 I would bet the driver on the client does not work with Easyprint. I would try the the HP Universal Print Driver or the driver for a printer that is very close, like the HP 1018.
Thanks,
Jeremy -
CRVS2010 Beta - Crystal Report does not work with VS 2010
After having installed vs 2010, as mentioned, I dowloaded crsytal report . But when trying to create a new crystal report object, I have a html page displayed but crystal report does not start. I would like to know how to make crystal report start to create new report ?
Thanks
Patrick
Subject modified as per the sticky post at the top of this forum; [Crystal Reports for Visual Studio 2010 Beta - read before posting|Crystal Reports for Visual Studio 2010 Beta - read before posting;
Thread moved to NET Development - Crystal Reports
Edited by: Ludek Uher on Aug 27, 2010 6:48 AMMy OS is windows XP. Visual studio 2010 Professional version 10.0.30319.1.rtm rel. Visual basic is 01018-532-2002102-70383. dot net framework is 4.0.30319 rtm rel. When I add a new crystal report object to my project a file named CrystalReport1.mht. Its content is :
From: <Saved by Windows Internet Explorer 8>
Subject: Crystal Reports for Visual Studio 2010
Date: Fri, 2 Oct 2009 17:24:34 -0700
MIME-Version: 1.0
Content-Type: multipart/related;
type="text/html";
boundary="----=_NextPart_000_0000_01CA4385.35B07AB0"
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.5579
This is a multi-part message in MIME format.
=_NextPart_000_0000_01CA4385.35B07AB0
Content-Type: text/html;
charset="utf-8"
Content-Transfer-Encoding: quoted-printable
Content-Location: file://C:\_Working\Projects\Cortez\Stub Templates\RTM\EN\CR for VS 2010 HTML\CRforVS2010.html
=EF=BB=BF<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
then followed by characters whch are not readable.
Thank you for your help
Patrick -
Wily Enterprise Manager Service not Started in Windows 2008 Server
Hi All,
Our Solution Manager is in EHP1 SP21 and OS-Windows 2008 Server.
We installed Wily Enterprise Manager 8.0. and found 1 non-fatal error in the installation log. The service is not starting.
However it works fine for Windows 2003 Server.
Can anyone encountered with the same kind of problem?
This is the latest log file information:
Summary
Installation: Successfulwith errors.
387 Successes
0 Warnings
1 NonFatalErrors
0 FatalErrors
Action Notes:
Execute ANT Script: Script:
Status: ERROR
Additional Notes: ERROR - E:\usr\sap\ccms\wilyintroscope\install\em.installer.exec.ant15.xml:425: Timeout: killed the sub-process
Thank you in advance.
Regards
SanjaiNote 1273028 - Introscope 8 Release Notes resoved this issue.
Known problems in all Releases 8.x
2. Windows Server 2008 is not yet officially supported by CA Wily for the Enterprise Manager. If you want to install the Enterprise Manager anyway, set the "Windows 2003 compatibility mode" for the installer before launching it. To activate this mode, right click on the installer.exe file in the Windows Explorer, select tab "Compatibility", activate the check box for compatibility mode and select Windows 2003. If you do not set this, the installer will consider your OS as Unix and install shell scripts (no suffix) instead of batch files (.bat) and leave out some files for Windows Service registration.
If the windows service still fails to start please check if files ServiceWrapper.jar and ServiceWrapper.dll are present in folder lib. If not download them from attachment of this note.
The service should start although giving an error message regarding the ServiceWrapper.dll. You can ignore this error. -
CR 10.2 not workin in Windows 2008 server 64bit
Hi everybody,
I've tried install CR10.2 on a Windows 2008 server 64bit but that doesn't work. After riding this interresting link : [wiki.sdn.sap.com|https://wiki.sdn.sap.com/wiki/pages/viewpage.action?pageId=56787567] I see this version is not supported by W2008.
Then I decide to install CR2008. I update my web.config to the new version and finally I test the web app. But I've some errors like : [sdn.sap.com|http://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes_boj/sdn_oss_boj_erq/sap%28bd1lbizjptawmq==%29/bc/bsp/spn/scn_bosap/notes%7B6163636573733d36393736354636443646363436353344333933393338323636393736354637333631373036453646373436353733354636453735364436323635373233443330333033303331333133383333333733303334%7D.do] I can't retake all files, because they are so much and this is not the solution. All of our client are working with 10.2 and we can't update the application just for one client.
How can I do for make it work with CR10.2 ?
Thank's for your help.
PS : I'm not fluent in englishHi,
Make sure that you are on CR 10.2 SP1
https://smpdl.sap-ag.de/~sapidp/012002523100006007872008E/crvs05sp1.exe.
Recompile the application.
You would need runtime.
https://smpdl.sap-ag.de/~sapidp/012002523100010010692008E/crredist2005_sp1_x86.zip
Then deploy the application to your server.
Also what method you have been using to deploy the application?
What is the version of Visual Studio?
Thanks,
Saurabh -
Crystal Report Export not working in Server 2008
Hi
Please Help..
I am Using Crystal report Report 9 with VB 6 and SQL Server 2008. All my Client PC s (Windows XP SP3) are able to export the reports in any format but with my SERVER - (Windows Server 2008 (32 Bit)) it isn't possible. The Button is very much enabled
but when I click on it, Nothing happens.. Please Help...Hi,
I would like to suggest you try to run SAP Crystal Reports under Compatibility Mode to check if it works.
Run in compatibility mode with administrative privilege
================================
1. Right-click the .exe file of the SAP Crystal Reports program and choose
Properties.
2. Switch to the
Compatibility tab.
3. Please check the
Run this program in compatibility mode for and choose
Windows XP (Service Pack 3).
4. Check the
Run this program as an administrator box under the
Privilege Level.
5. Click
Apply, click OK.
Note: If the option is unavailable when running this program as an administrator, it means that either the application is blocked from always
running elevated, the application does not require administrative credentials to run, or you are not logged into the computer as an administrator.
If it does not work, it is high recommended to contact your local SAP Support Engineers for further assistance. They are more familiar with their own
product.
Regards,
Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread. -
SAP Crystal Reports 2011: Error INS00140 on Windows 7
I am trying to install on Windows 7, and I am getting the error 'The Product keycode is not valid: INS00140'
When I run the isKeycodeValid.exe directly I get this:
Info: found Aurora type "D" keycode
Could not resolve the location of isKeyCodeValid.exe at: isKeycodeValid.exe
Then it crashes with:
Problem signature:
Problem Event Name: APPCRASH
Application Name: isKeycodeValid.exe
Application Version: 14.0.2.364
Application Timestamp: 4de9a453
Fault Module Name: cryptocme2.dll
Fault Module Version: 0.0.0.0
Fault Module Timestamp: 46cb9da8
Exception Code: c0000005
Exception Offset: 000246c7
OS Version: 6.1.7600.2.0.0.256.4
Locale ID: 1033
Additional Information 1: 0a9e
Additional Information 2: 0a9e372d3b4ad19135b953a78882e789
Additional Information 3: 0a9e
Additional Information 4: 0a9e372d3b4ad19135b953a78882e789
Any ideas?
Thanks.Hello,
It's also been noted that an old version of Adobe Reader copied into the windowssystem32 folder. They have changed their ways but that old software did not clean it up. As well as McAffee also uses an older version.
Search your PC for that file, is it in any folder?
A test is to rename the one you find and copy the one from CR into that app's folder, reboot and test again.
We have extensive discussions and post on this issue in the .NET SDK forum due to install issues for the runtime for Crystal Reports.
See this thread for more info: Re: Installing CR for VS2010 throws 1904 Exception - fails to register many dll
Bottom line is this set of dll's are for Encryption and there are updated versions. CR requires a recent version, older programs that have the dll loaded into memory do not have the new functions of the updated dll. Because of the way Windows works if a dll with the same name is in memory all applications can and will use it. They can't load another version, it's the way Windows works....
CA resolved the issue by renaming their version of the dll because they too were putting their app in the PATH statement.
Only other option is to report this issue to CREDANT and see if they can "fix" their version issue.
Don
Edited by: Don Williams on Oct 7, 2011 9:12 AM -
Crystal Reports has stopped working with Windows 7 and demo database
I'm trying to get back up to speed on Crystal Reports after 10 years away. I'm running Crystal Reports 2008 Standard with the just-released Service Pack 3 (same symptom with SP2).
So I downloaded the demo database and tried creating a new report. No problems creating a simple customer list. When I add the Orders table and link the CustomerID columns and then add the OrderDate column to the report, everything works fine. But as soon as I add the OrderID or OrderDate column, the application crashes.
Culprit seems to be MSVCR80.dll. Here's the log:
Faulting application name: crw32.exe, version: 12.3.0.601, time stamp: 0x4bd05d31
Faulting module name: MSVCR80.dll, version: 8.0.50727.4927, time stamp: 0x4a2752ff
Exception code: 0xc000000d
Fault offset: 0x00008aa0
Faulting process id: 0x1944
Faulting application start time: 0x01cb0139cfafeb40
Faulting application path: C:\Program Files\Business Objects\BusinessObjects Enterprise 12.0\win32_x86\crw32.exe
Faulting module path: C:\Windows\WinSxS\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.4927_none_d08a205e442db5b5\MSVCR80.dll
Report Id: 3b28c990-6d2d-11df-b9d8-00080d72c9f2
Suggestions? Thanks in advance.Hello,
It may be that something was "fixed" and our default xml file falls out of the Standards now.
Are you wanting to connect to SQL or XML?
Go to Microsoft's site and search for C++ distribution and download and install the recommended one for windows 7. It may be that part is corrupt or our installer thinks it is there. Try doing a Repair install and custom options to select all of the DB drivers and exports types to see if that resolves the issue.
Thank you
Don -
Reports 6i Not working in Windows 7, 64Bit
Dear,
We have Forms and Reports 6i which is perfectly running its reports in windows xp pc and even in windows 98 pc.
But recently we have installed windows 7 64 bit, but
the reports not working here.
what might be the problem what shall we do to handle this
problem?
Report Version: Report Builder 6.0.8.24.0
Regards,
Stanlee...Thanks for the Reply...
Yeah i downloaded the ddl files and replaced
the DDL files in the oracle directory Bin folder.
from the below download link.
http://www.orafaq.com/forum/t/124421/0/
Now reports working fine.
Regards,
Stanlee... -
System.Windows.Forms.SaveFileDialog not working under Windows 2008 R2 Server
I am using Windows Server 2008 R2 (64-bit) that is been virtualized with Hyper-V and it is being used as a "Remote Desktop Server".
I am trying to use this PowerShell code that will open a "Save-File-Dialog" box to select the PDF file and send it to my "batch" file for scanning. This code works great on my Windows Vista machine and my Windows 7 32-bit machine
but I cannot get it to work on the "Windows 2008 R2 Server (64-bit)". It will not come up with any window at all and it will not produce any errors at all, so I can't exactly google for this issue. I am using PowerShell 2.0 from 2009.
Any ideas? I tried it from an Admin account and a regular domain users and neither worked at all, no errors, no window, no nothing.
*** Update ***
I took Out-Null out and I received this...
GAC Version Location
True v2.0.50727 C:\Windows\assembly\GAC_MSIL\System.Windows.Forms\2.0.0.0__b77a5c561934e089\System.Windows.Forms.dll
I then checked the path and the DLL file was in there and it had read and execute permissions for Domain users and Administrators and the window still won't pop up...
Here is the entire code in question.....
# Uses the dot net assembly to give the users a Save-File-Dialog box so they can decide where to put the pdf file
Function Get-SaveFile($initialDirectory){
[System.Reflection.Assembly]::LoadWithPartialName("System.windows.forms") | Out-Null
$SaveFileDialog = New-Object System.Windows.Forms.SaveFileDialog
$SaveFileDialog.initialDirectory = $initialDirectory
$SaveFileDialog.filter = "PDF files (*.pdf)| *.pdf"
$SaveFileDialog.ShowDialog() | Out-Null
$SaveFileDialog.filename
# open dialog box to select the .nessuss file.
$OutputFile = Get-SaveFile
# User selected where they want to put the scanned.pdf file and it will automatically set it to .pdf for them
start-process Scan $OutputFileI ran the code you have in your function on a Windows 2008 Standard server, and it seems to be hanging on the line
$SaveFileDialog.ShowDialog()
| Out-Null
It just sits there and nothing happens, but if I run it on my Windows 7 machines, it runs without any issues. So it seems like the dialog opened, but behind the scenes, and is waiting on the user, but since it doesn't open, the user can't do anything.
If you find that my post has answered your question, please mark it as the answer. If you find my post to be helpful in anyway, please click vote as helpful.
Don't Retire Technet -
Re: Toshiba Store Alu 3.5" 1TB HDD not working with Windows 2008 64-bit
Just bought this as a backup device for Small Business Server 2008 which runs on Windows 2008 64-bit. However it does not recognise it? Are there any drivers anywhere for this or is it just not supported and I need to buy an alternative?
Connected it to my Windows 7 64-bit laptop and no problems there.
Anyone else had same problem?Hi
Unfortunately, there is no other software for download.
I checked the Toshiba driver page in Options area but didnt find anything
As far as I know its a plug & play HDD so you dont need any software in order to recognize the HDD
Possibly there is a password protection.
Try this:
Connect your HDD to the PC where the HDD is working
select the CD Drive (Password) with your Explorer
run the ONSPCLCK.exe
select "Options"
select "Disable Password Security"
enter your Current Password
unplug the HDD
connect the HDD
Now it will work but without any password protection. Maybe it would works -
Reposcan x64 will not run under Windows 2008 Server R2....
Hello,
When i run from the command line
reposcan.exe -dbdriver sqlserverdatabasesubsytem -connect u201CUID=xx;PWD=xxxxxxx;DSN=xxxxxxxxu201D -dbkey xxxxxxx -inputfrsdir u201CC:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore\Inputu201D -outputfrsdir u201CC:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore\Outputu201D -outputdir "c:\reposcan logs" -repair true
reposcan pops up for 1 second and closes, no log outputed
I have also tried...
A text file called Reposcan.txt
-dbdriver sqlserverdatabasesubsytem
-connect u201CUID=xx;PWD=xxxxxx;DSN=xxxxxxxxxu201D
-dbkey Linfxxxxxxx
-inputfrsdir u201CC:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore\Inputu201D
-outputfrsdir u201CC:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore\Outputu201D
-repair false
"C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\win64_x64\reposcan.exe" -optionsfile "C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\win64_x64\reposcan.txt"
none of the above work, any ideas?
I am running with admin privliage
Edited by: davitali on Dec 28, 2011 3:58 PMProblem solved.
Solution:
1. Create two files, Reposcan.bat and Reposcan.txt
2. In windows 2008 x64, right click on reposcan.bat and select "Run as Administrator"
3. When running the first time, remove the "-repair" option from reposcan.txt. Check the results in the ouput diectory
4. Before inserting the repair option, backup CMS, CMS_Audit tables and also the entire Business Objects Directory
Reposcan.bat
"C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\win64_x64\reposcan.exe" -optionsfile "C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\win64_x64\reposcan.txt"
Reposcan.txt
-dbdriver sqlserverdatabasesubsystem
-connect "UID=xx;PWD=xxxxxx;DSN=xxxxxxxxx"
-dbkey xxxx
-repair
-inputfrsdir "C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore\Input"
-outputfrsdir "C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore\Output"
-outputdir "C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\reposcan" -
JConsole not working on Windows 2003 Server
Hi Friends,
I'm trying to use JConsole on a Windows 2003 (service pack#2) to monitor the performance of Tomcat application.
For some reason, JConsole is not able to attach to the PID (Process Id) of Tomcat. The error I see from JConsole is *"Invalid process Id".* However, I'm using the correct PID of Tomcat listed in the Windows Task manager. I repeat, that the PID of Tomcat is exactly the same what is shown in the Windows Task Manager.
Here is the command am using to launch the JConsole
JConsole <PID of Tomcat>.
JConsole 632
JConsole 4432
JConsole localhost:8080 (
Note: the same steps work good on WindowsXP.
Here is version of JDK we are using on my system.
=====================================
java version "1.6.0_06"
Java(TM) SE Runtime Environment (build 1.6.0_06-b02)
Java HotSpot(TM) Client VM (build 10.0-b22, mixed mode)
C:\Sun\java_ee_sdk5.05\jdk\bin>
Tomcat version:
============
Using CATALINA_BASE: C:\apache-tomcat-5.5.17
Using CATALINA_HOME: C:\apache-tomcat-5.5.17
Using CATALINA_TMPDIR: C:\apache-tomcat-5.5.17\temp
Using JRE_HOME: C:\Program Files\Java\jdk1.5.0_02
Server version: Apache Tomcat/5.5.17
Server built: Apr 14 2006 02:08:29
Server number: 5.5.17.0
OS Name: Windows 2003
OS Version: 5.2
Architecture: x86
JVM Version: 1.5.0_02-b09
JVM Vendor: Sun Microsystems Inc.
Any help would really be appreciated.
ThanksBut the link is not working.What does this mean ? What browser is used ?
I tried to Restart the webserver by srtartPIA.cmd script but it is not workingAgain, "not working" does not mean much for us on the other side of the network.
Please show us any errors.
Nicolas. -
Crystal Report XI not updating correctly within CR Server
Greetings. I have a report that I have created using Crystal Reports XI. I then have published it and set it up within Crystal Reports SERVER to automatically run on a daily basis. The report automatically runs with no errors, however, when you look at the data, it does not reflect the current database - instead shows the data from whever it was published. Thus, the reports look like they are updated daily, however the information inside shows that they are not.
Any help/tips/advice on what to look for to fix this problem would greatly help! I'm new to Crystal Reports Server.
Thanks,
PamI have them set up on the Crystal Reports side, then when I publish them, the database information is "grayed out", so the reports initially don't run once published. So, I then log into the CMS using the ADMIN password and set the database parameters. The reports run fine and the data is saved with the report (only if I publish the report with the data saved). However, the next day (assuming you have daily reoccurence setup), the report is the initially published contents, not the "refresh".
I am probably missing some "simple" step...but being a newbie to this, I'm obviously missing it! Any advice is greatly appreciated!
Pam
Maybe you are looking for
-
I updated my phone today on our family itunes account. I currently have the iphone 4 and needed updates. At the end of the update I got a message that my phone info would now be the same as my daughter's ( who usually uses the itune account). I didn
-
Error Deploying A Cube with the Deploy All option
Hi All, I get the error below when I try to deploy a cube: ORA-06510: PL/SQL: unhandled user-defined exception ORA-06512: at "OLAPSYS.CWM2_OLAP_UTILITY", line 1660 ORA-01403: no data found ORA-06512: at "OLAPSYS.CWM2_OLAP_CUBE", line 33 ORA-06512: at
-
Windows phone no longer syncing...
Hi there I did the Cyan update, seems great! Except my hotmail and onedrive no longer sync and I can't even open or uninstall onedrive and I gather you have to do a hard reset to delete the hotmail account! Can anyone advise of anything else to do pl
-
Looking up JNDI in Weblogic 5.1.0 server
I have written a simple stateless session bean in weblogic 5 server. The bean has been deployed etc. I am having problems in accessing it from the client. My client code is as under: Its giving an exception in getting the initail context in the line-
-
Trying to un-hide content type using powershell
I'm using this script below and am writing back the library name and if the content type is hidden after the update. Everything points to being correct yet when I go back to the library settings the eDocument Link is still hidden. What am I missing?