Dear colleagues!
I am new to LabView and I am only starting to learn the system (I have never been a programmer, I'm a chemist to be precise).
I have before me a task to interface an old analog scanning spectrophotometer to PC via LabView.
It has two output analog channels: one is wavelength (two ranges, currenlty let it be 190 to 390 nm; it reads on multimeter as 0.19-0.39 V range) and another one is absorbance (0-1V range). An UV spectrum sholud be an X-Y graph wherein X is wavelength and Y is absorbance.
I am able to read one channel OR another. I am able to read BOTH channels simultaneously, but how can I plot them AGAINST each other, not against TIME?
I am using DAQPad-1200 (LPT interface) and LabView 6.1 (that's why I am unable to read most of the VI's posted on the forum ).
Is such an interfacing even possible given my software and hardware limitations???
Thank you all in advance!

Thanks a lot, johnsold!
I am now able to get something which looks like an UV spectrum! %)
1. I will post an image (later); however, my primary objective is to get two columns of numbers, not necessary to see an X-Y graph onscreen.
2. Without inserting arrays like I did LV always tells about error connecting this data line from two channels to save "2-D data to file" option telling me that input is 1D!
3. I have a manual for the device, it has all of the schematics. I am no electrician though. I will post scanned circuit diagrams then when I manage to scan them.
Now I see two more opportunities to control the device.
A. There is a circuit (+12V DC) on the rear of one of the modlues, which, if shorted for at least 500 milliseconds (according to Tracor manual) can initialize automatic scan. How can this be done using Labview and DAQ device? My first guess is to use an analog output and some kind of a relay, either electromagentic or semiconductor one. Is there any other possibility?
B. In my code I am always asked to write to a file after I initialize the sequence. Can this be done AFTER the sequence is finished?
C. Finally, is it possible to automatically stop the While loop when the number generated by shift register becomes equal to 190?
Here are attached a new code and a sample of data.
Attachments:
Tracor970A-v1.0.vi ‏53 KB
UV-test-01.txt ‏15 KB

Similar Messages

  • I want to use two analog channels and one digital simultaneo​usly

    Hello and thanks in advance for reading this!
    What I am trying to do is generate two different signals from the output channels of my interface card (PCI6024E) and simultaneously use a digital line so that I can switch two tranzistors (one NPN, one PNP) which actually control the "flow" of the two signals. This means that both signals need to be "active" while the VI is running and at the same time whenever I want to choose the signal not in use I need to use the digital line so that I switch the tranzistors and I get the desired signal.
    I have already created a VI which activates a digital line and while I was trying to add with the NI-DAQmx Assistant the first digital output, I discovered that it c
    ould not be used simultaneously, because there was the error code -200324 saying that "Device not available in NI-DAQmx. It is possible that the device is being used by Traditional NI-DAQ or that the device is being reset."
    I did reset the device but as I get it when VI runs, it cannot have an active digital channel and an analog output channel at the same time (not to mention two analog channels). Correct me (And make my day if I am wrong but this seems to be the case. Thanks a lot for your time!

    Hey Shootist000,  Thanks for the replies.  First off, I am actually okay if we both have each other applications so I am not concerned about that. It is still unclear from what you have said as to whether I can in fact, use these two separte time machine backup to create two separate profiles on the new hard drive.  If that in fact can be done, then - will it create two copies of the apps we both have in the ROOT of the drive as well as placing all the ones we each have separately?
    And reading your second reply, makes me think that maybe the partition is the way to go to begin with and then down the road - after I am in the new iMac, I could reformat the iMac 27 with only one partion and restore my son's latest back prior to the reformat thus giving him full access to the 2 TB of the drive.
    If this is still making sense, does this mean :
    replace the 1TB with a 2TB - but have it partitione - 1.5 TB & 500 GB.
    Install(Restore using Time Machine) my latest back up prior to the  1.5 partition
    Install (Restore using Time Machine) my son's latest back up prior to the 500 gig partition
    Lastly, in order for us both to be using the partioned computer - I am assuming Switch user can no longer be used - so would we need to restart and select our respective partions in order to use the computer?   And if so, how would we each be able to be using time machine to back up - two separte external hard drives - with each one dedicated to only one partition? Or ? 
    Thanks so much.
    Ironically, I am only trying to do this so that I don't need to manually install all his apps, setting, games, blah blah for this temporary period.  :-)

  • How to use DAQ Assistant to display two analog channels in a XY Graph

    Hi,
    I am new to LabVIEW. I have been assigned a project in which i have to display two analog signals from an analog potentiostat i.e. voltage and current (also a voltage signal) on a graph using labview. I am using a myDAQ device to acquire these analog signals and I am using labview 2013 to display these signals on a graph. I am using DAQ assistant to configure these signals. Rightnow I have separate graphs for each channel. However, I want a single XY graph to display one voltage as a function of the other i.e. I want to have voltage on the X-axis and current output on the Y axis. Any kind of help is greatly appreciated.
    I have attached a screenshot of the VI. that I have made.
    Regards,
    Max
    Attachments:
    New Microsoft Word Document (2).docx ‏32 KB

    Thanks for the quick response. I was able to make a X-Y graph. However, I can only see a dot floating around. It's not drawing anything. I want to see it making a plot as it collects data. Also, I want to see the complete waveform formed when I stop the VI.
    Thanks,
    Max

  • Data retrieve from tables in two diff schema in same db

    hi,
    i have one db and name is HWRDB, in this i have two schema PRLHEEP and PRLCFFP.
    in PRLHEEP my table is NAMAS, and in PRLCFFP also table's name is NAMAS.
    i want
    if :unit = 'H' then
    -- connect to PRLHEEP
    select data into some items from NAMAS
    eslif :unit = 'C' then
    -- connect to PRLCFFP
    select data into some items from NAMAS
    endif;
    plz help me to connect to schema. *** db is oracle db, 10g version***

    here is my code,
    if :deloan.unit = 'H' then
    ....... select nmodpay,nbnkacc
    .......into modpay, bnkacc
    .......from namas where nstfno = :deloan.stfno;
    .......select some colums
    .......into some items
    .......from pafac
    ....... where pstfno = :deloan.stfno and
    elsif :deloan.unit = 'C' then
    ....... select nmodpay,nbnkacc
    .......into modpay, bnkacc
    ....... from prlcffp.namas where nstfno = :deloan.stfno;
    .......select some colums
    ....... into some items
    ....... from prlcffp.pafac
    .......where pstfno = :deloan.stfno and
    in forms builder, i connect to prlheep
    when i compile i get errors:
    identifier *'PRLCFFP.NAMAS'* must be declared
    identifier *'PRLCFFP.PAFAC'* must be declared

  • How to visualise continues Data aquisition from a PCI 6602 with 2121 BNC connector board in C++ ?

    Hello everyone,
    We are trying to get on the screen the aquired pulses from our  PCI 6602 with a 2121 BNC connector board, from several devices. We are able to read the data and save without problem, but we cannot look at it while we are measuring. Anybody has an idea to how program this in C++ ? Any suggestion is welcome!
    Thanks for the help

    Hi,
    try to look for some example programs and Tutorials:
    Examples Results
    http://search.ni.com/nisearch/app/main/p/bot/no/ap/tech/lang/en/pg/1/sn/catnav:ex/q/DAQmx%20C%2B%2B/...
    Tutorials Results
    http://search.ni.com/nisearch/app/main/p/bot/no/ap/tech/lang/en/pg/1/sn/catnav:tu/q/DAQmx%20C%2B%2B/...
    You should also have a look at the "C Reference Help" which is installed with the NI DAQmx driver.
    Acquire N Scans (Visual C++ 6.0, CW++, NI-DAQ)
    http://zone.ni.com/devzone/cda/epd/p/id/207
    Continuous Analog Acquisition with Producer Consumer Architecture in C#
    https://decibel.ni.com/content/docs/DOC-4253
    Good Luck!
    Matteo

  • Build view with data rows from one of two views.

    Hello. I've got problem with PL/SQL.
    I have built two PL/SQL views. Now I have to write a third
    view based on the data from "view_1" or "view_2". "view_2" contains all data rows
    but "view_1" contains special information. If the needed data rows (it's
    always a tupel of two rows) are available in "view_1" i have to use these data.
    Are they not available in "view_1" i have to get it from the second view.
    I've tried it with the DECODE function and a procedure I've written but I think it's
    the completly wrong way because I have to search for a tour_id and there are always
    two shipments for one tour.
    It looks something like:
    >
    SELECT
    DECODE(FNC_OPERATION_INSTRUCTION_EXISTS(T1.TOURNO),0,
    (SELECT SHIPPING_NO
    FROM VIEW_SHIPPINGADRESS
    WHERE TOUR_ID=TO_CHAR(T1.TOURNO)),
    (SELECT SHIPPING_NO
    FROM VIEW_SHIPPINGADRESS_OPERATION_INSTRUCTION
    WHERE TOUR_ID=TO_CHAR(T1.TOURNO)) "SHIPPING_NO"
    FROM
    TB_TOURS     T1
    WHERE
    But for sure I've got the error "ORA-01427: single-row subquery returns more than one row."
    because there are always two rows for one T1.TOURNO.
    I think that it's a standard problem but I also think that I'm on the wrong way.
    I will be very thankful for any hint.
    Thanx,
    Christoph

    select col1,
           col2,
           col3
      from  (select (select decode(count(*),0,0,1) cnt
                       from view_1
                      where ...)) chk,
                     col1,
                     col2,
                     col3
               from view_1
              where ...) tab1
    where tab1.chk = 1
    union all
    select col1,
           col2,
           col3
      from  (select (select decode(count(*),0,0,1) cnt
                       from view_1
                      where ...)) chk,
                     col1,
                     col2,
                     col3
               from view_2
              where ...) tab1
    where tab1.chk = 0note: untested.

  • One user receiving WINMAIL.DAT attachments from one or two domains

    I have a single user in our organization that is RECEIVING WINMAIL.DAT attachments which contain PDF's from only one or two domains external to the organization.
    Let me be clear that he is not sending out WINMAIL.DAT attachments to anyone. I have tested sending him RTF emails with a PDF attachment from an external address and he is receiving them just fine. We are running two Exchange 2013 servers in
    HA configuration and this user is using Outlook 2010 for his email client. If he looks at these messages in OWA, they still have the WINMAIL.DAT attachment within OWA. I cannot find an answer for this anywhere, and this is not related to disabling TNEF on
    our exchange servers.  Does anyone have any ideas?  I would really appreciate the assistance.
    Thanks,
    Dean

    Hi
    Did you try this article -
    http://support.microsoft.com/kb/278061/en-us
    If the above article did not help then you can try the following
    1) Create an external contact for sender email address from whom the email is sent to the affected user.
    Run the below command for that sender external contact
    Set-MailContact "External Contact" -UseMapiRichTexFormat Never
    Ask the user to send email once again to that affected recipient and see if it still occurs.
    Most likely the latter should fix your problem.
    Please mark as helpful if you find my contribution useful or as an answer if it does answer your question.That will encourage me - and others - to take time out to help you.
    Regards,
    Sathish

  • Data Aquisition from HP 54504A

    I have an older model HP 54504A Digitizing Oscilloscope, and I need to create a LabVIEW program that can pull data off the scope. I also need to be able to capture an eye-diagram, which will require repetitive sampling to acquire a large number of data points. I was wondering if anyone had a simliar program that I could use as a reference in create mine. Thanks in advance.

    Hi Trigeek,
    I do not have personal experience with this device, but you might check this site for a driver for your instrument. I'm not sure if there is one for this instrument or not but you might be able to find a driver for a similar instrument that you can modify. Maybe someone else who has experience with this instrument will post an example for you. Hope this helps.
    JenK

  • Acquiring data from all the analog channels of NI-3202 NODE using a single sensor

    Hi all,
    I would like to know that can i be able to get the data from all the four analog channels of NI-WSN node 3202(analog input node) connecting only single sensor on the analog input and connecting all the remaining analog inputs using wires and also shorting the ground pins corresponding to each analog input pin.
    By configuring the each channels like 0.5 sec delay for every analog channels to acquire data. can we get the sensor data from all the channels by doing this. basically here i am trying to increase the minimum sampling rate of the ni-wsn NODE 3202 which is 1s.
    I this approach is correct or we cannot do this.
    Thanks

    Stefan,
    In terms of differential and RSE, channels 0-8 should default to differential when using test panels.  Differential needs two input channels to function correctly and these channels must be spread apart by 8 channels. (i.e channels 0 and 7 are a differential pair)  Channel 13, on the other hand, will default to rse if chosen as the reading channel because there does not exist another channel that is eight away.  I am not quiet sure if the virtual channels will default channel 5 into being differential but I will check into it.  If it is differential as default then you may run into problems since channel 13 is utilized in both strain gauge reads.   
    "The second question is, if we can also use the "voltage" setting for measuring strain gauges? we did that in the past, using LabView 6.2."
    If you are referring to "voltage" as acquiring a signal with custom voltage with exciation then I would reccomend using example in LabVIEW called Acq Wheatstone Bridge Samples (with Calibration).  This can be found by navigating to LabVIEW's example finder and expanding Hardware Input and Output>>DAQmx>>Analog Measurements>>Strain.
    I have also included some useful links that may provide more insight into the SCC modules as well.  Also, what is the excitation voltage and power that your strain gauges are expecting?
    SCC Tutorial Series: SCC-SG0x
    SCC Example Series: SCC-SG0x
    Using the SCC-SG11 Shunt Calibration Module
    Thanks,
    Gio L.
    Digital Support - Product Manager
    National Instruments

  • How to send out two analog signals

    hi
    I'm running Labview 10.0 with a PXI controller 8196 with with an M-series DAQ board 6289 which has 4 analog out ports. What I have done is create a statemachine which controls a multi LED board (57 LEDs arranged in 7 concentric circles, with a centre LED). The state machine moves between various states such as Fixation point on, Fixation point off, Target on, Target off. At the moment I have one Analog out port which outputs a voltage to tell me which state I am in, but I want to know how to configure a second port to say which LED I am turning on. I am controlling the LED with the digital out, and converting a binary to a digital code so I was just going to convert that digital code (by diving it by some factor) and write out that factor to a second port. I've read I can not confiure two Analog out ports on the same board, but instead I have to cluster the outputs together, I'm just not sure now to do that. I've attached my main vi as well as the two subvi's that the main vi calls. I've looked at some of the other threads and the suggestion was to close one port to open the other, that's just not possible in my case as I need to keep both channels open throughout the whole program as the analog out is constantly changing. I'm also recording from up to 25 analog channels at the same time.
    Thanks in advance
    NB. I could only add two of the sub vi's that the main program calls, so the main vi will not work, so if need be I can post the other sub vi in an additional post.
    Attachments:
    VisDisplay_v1.vi ‏121 KB
    Build Table_v3.vi ‏45 KB
    LEDon.vi ‏24 KB

    Hi
    For one of the channels it is a stepping voltage which changes between +/- 5 volts depending of which state of the statemachine the program is in, so it is not just a constant voltage through out the whole task. On the second channel I want to out put a single voltage that would signify which LED is turning on, that would just be a constant voltage, but it would not be the same voltage on both channels. I'm just about to try something else and hopefully that will work.
    Thanks
    Sam

  • DAQ write+read analog channels

    Hi,
    I need some urgent help to solve a simple problem:
    My job is to write an analog channel to a DAQ device and then to read two analog channels from the same device.
    These should be done at the 5 KHz rate.
    For smaller rates I can do it using normal loops (or timed loops). But I don't know how to do it using DAQ features.
    Please give me an example.
    I have found something but I am not sure if it can be used in this way (see the attachment)
    Thank you!
    Solved!
    Go to Solution.
    Attachments:
    DAQ Test write analog+read analog.vi ‏49 KB

    Mcdan wrote:
    Quick correction to my last post... I did not notice that your original VI called DAQmx Start.  In this case I think it is preferred to call start before your loop rather than calling commit, since start will put the tasks in running state outside of the while loop.  In Jeff's proposed change, the tasks would need to transition from committed to running and then back to committed each iteration of the loop.  As originally written, the tasks will be in the running state before the while loop and remain there until they are cleared.
    Dan
    Dan- You missed the Autostart(T)-  and, ALL tasks go from committed to run and back to committed,( unless abnormally terminated by a explicit abort while running starting from a state other than committed,) the commit state is the least overhead for any task that is not continuous or regenerating.  The original post started the task from Verify state- and required DAQmx to reserve and commit the DAQ resources for each read or write and then (since it Started from verify) implictilly uncommit and un reserve the resouce after "running" in each loop iteration.  Sean N "Popped-the-hood" and gave difinitive advice on the DAQmx task state handeler in this post (warning ----wrap head with duct tape before reading) 
    Sorry to derail the thread but, accuracy counts too.  I can't let a user stay stuck behind an "8-ball" with misconceptions (nice avatar by the way)
    Jeff

  • How to modify the VB examples in ni-scope to sample data simultaneously from two channels in PCI 5922?

     Dear all:
    I want to write VB programs to sample data simultaneously from two channels in PCI 5922. The niscope driver has some example VB programs to sample data from one channel, for example, the "save to file ", the program works well to sample the data from one channel.  When I modify it to sample data simultaneously from two channels, I always get error so I seek your help on how to write the program to sample two channels simulatenously. Thanks.  I attached the sample program here and what I tried to modify is the "channel name" and "waveform()"
    Regards
    Andy
    Attachments:
    savetofile.doc ‏42 KB

    Hi Bajaf, regarding the FFT of the four channels, the next link might be what your looking for:
    http://digital.ni.com/public.nsf/allkb/862567530005f09c8625671b00739970
    Respect the phase issue how are you doing the acquisition of the signals, are you doing two independent acquisitions? if you are controlling them as independent acquisitions try to synchronize them with triggers and the clock.
    How much are they out of phase?
    By the way we know have forums in Spanish
    Best Regards
    Benjamin C
    Senior Systems Engineer // CLA // CLED // CTD

  • Data acquisition from analog start trigger to analog stop trigger

    Hi,
    I'm trying to start and to stop a data aquisition by using an analog input trigger. I'm using NI-USB-6251. At input channel ai0 is a sin-signal connected. At input channel apfi0 is an analog trigger signal connected. I can start the trigger signal by pushing a button on my frequency generator. Here's a part of my code:
    Hi,
    ich versuche eine Messung mit einem analogen Eingangssignal zu starten und zu beenden. Ich benutze die Messkarte NI-USB-6251. An Eingang ai0 ist ein Sinus-Signal angeschlossen. An Eingang apfi0 ist der Triggereingang angeschlossen. Das Triggersignal löse ich immer per Tastendruck auf dem Funktionsgenerator aus. Hier ist ein Teil des Quellcodes:
    TaskHandle taskHandle = 0;
    int32 read;
    float64 *data;
    float64 sampleRate = 1000; //Samples per Channel per Second
    uInt64 sampsPerChan = 4000; //Samples per Channel to read
    int sumOfChan = 1;
    double triggerLevel = 2.0;
    double min = -0.2;
    double max = 0.2;
    double timeOutReadAnalog = 10.0;
    void calculate()
    DAQmxCreateTask("", &taskHandle);
    DAQmxCreateAIVoltageChan(taskHandle, "/dev1/ai0", "", DAQmx_Val_Cfg_Default, min, max, DAQmx_Val_Volts, NULL);
    DAQmxCfgSampClkTiming(taskHandle, "", sampleRate, DAQmx_Val_Rising, DAQmx_Val_FiniteSamps, sampsPerChan);
    DAQmxCfgAnlgEdgeStartTrig (taskHandle, "/dev1/apfi0", DAQmx_Val_RisingSlope, triggerLevel);
    DAQmxCfgAnlgEdgeRefTrig (taskHandle, "/dev1/apfi0", DAQmx_Val_RisingSlope, triggerLevel, 3000);
    DAQmxStartTask(taskHandle);
    if( (data=malloc(sampsPerChan*sumOfChan*sizeof(float64)))==NULL )
    MessagePopup("Error","Not enough memory");
    //set start and stop trigger
    //set breakpoint here
    DAQmxReadAnalogF64 (taskHandle, -1, timeOutReadAnalog, DAQmx_Val_GroupByChannel, data, (sampsPerChan * sumOfChan), &read, NULL);
    I've choosen the sample rate (1000/s) and the samples per channel (4000), that the aquisition needs 4 seconds to be complete. I can start the aquisition by Start-Trigger, but I think I have a problem with the function DAQmxCfgAnlgEdgeRefTrig. Actually the array will always be filled with 4000 values. I thought I can start the aquisition by triggering once and e.g. after two seconds triggering again for stopping aquisition with result of 2000 values in the array. I hope you can help me with this problem.
    Ich habe die Sample Rate (1000/s) und die Samples pro Kanal (4000) so gewählt, dass die Aufzeichnung 4 Sekunden dauert. Ich schaffe es auch die Aufzeichnung über den Trigger zu starten, jedoch funktioniert das Stoppen mit der Funktion DAQmxCfgAnlgEdgeRefTrig nicht. Aktuell ist es so, dass das Array immer mit 4000 Werten gefüllt wird.
    Ich hatte mir erhofft, dass ich durch einmalige Triggerung die Messung starten kann und beispielsweise nach zwei Sekunden erneut triggere und die Messung damit stoppe und dann nur 2000 Werte eingelesen habe.
    Ich hoffe, ihr könnt mir dabei helfen.

    Hi Martin,
    I looked over your code and noticed that you called the function without checking the returnvalue.
    Try to change the line to the following:
    First: define a new int32 value and call it for example: errorcode
    Second: The function returns a status code, wich if it fails, includes an error code so save this code in the new generated value
    errorcode = DAQmxCfgAnlgEdgeRefTrig (taskHandle, "/dev1/apfi0", DAQmx_Val_RisingSlope, triggerLevel, 3000);
    and try to run the programm and read out this value.
    If you got this value, please post it here and I will try to help you if I can.
    Regards
    Philipp

  • Help! data manipulation for high speed streaming to disk from multiple boards and multiple channels

    I am using Labview 7.1 and have been trying to capture data from 12 channels simutaneously sampled at 2MS/s each and streaming to disk for up to a minute or more.  The hardware I am using is 2 x PXI 6133 S series boards with a MXI4 link to a Pentium D 2.8 Ghz machine with 2Gb ram.   I have 2 sata drives set up in a raid 0 configuration which should give me hard disk write speed faster or equal to the MXI-4 transfer speed. 
    I have first started off by using the example code "multi device sync - analog input- cont acquisition" which has enabled me to sync the two boards and sample at the required speed. 
    To stream the data to disk, I have first merged the data from each board  together to save it to one file.  I have tried using the storage vi's but I end up with a Daqmx read error (trying to read data that is no longer available).  I have played around with the read data size to the point that I either get a insufficient memory error, or I get the "trying to read data that is no longer available"  error.  I have also tried using the file IO blocks with some success and have found that I have been able to stream to disk only if I configure the daqmx read block to output the data in "raw 1D I16" format and plugging it into the file-write block.  In doing this, I have noticed that using  multiple channels on one daqmx read task, I will get all the channels in one 1D array rather than a 2D array organized by channels.  This makes it messy to read at the end of this, and I also don't want to write another vi to separate the channels, due to the high chance of getting the data mixed or messed up if I happen to change the number of channels on a board
    Is there a cleaner way of streaming this data to disk and keeping the channel data separated from each other?, and/or is there a better way to capture and handle the data I need? 
    I have attached the vi which I have got to consistantly work streaming to disk using the raw 1D I16 format.
    Thanks in advance to anyone who can help.
    Attachments:
    multidevicesync_analoginput_streamtodisk.vi ‏197 KB

    Hi,
    i can suggest following
    Refer to an example VI called as "High speed data logger.VI"  in conjunction with "High Speed data logger reader.vi" in Labview examples. Alhrough the logger might be in Tradiditional Daq format, it can be quite easily converted to Daq Mx format to store data in Binary (I32 format) . I have used this for many of my applications and i have found that the data retrieved does not have any "messups".
    Why not keep a seperate file for each card? This way, you do not have to load your application with extra process. You only have to acquire and save. After saving in Binbary format, you can retrive it offline, convert it to ascii format and merge the data files of various cards to get one consolidated ascii data file.
    hope this helps
    Regards
    Dev

  • How to make a synchronous acquisition of two analog signals with a one channel DAQ ?

    Hi !
    It is the first time I use Labview. I have just made some easy VIs, and now, I do not know how to deal with my problem...
    My problem : I have only one acquisition card (DAQ Ni 6034E) and I would like
    to acquire simultaneously two analog signals. It seems to be possible, in a quasi-synchronous acquisition if the card acquires one point of the first signal, then the first point of the second signal, then the second of the first signal, and so on ... I thougth that I could made two sequencies with a VI of data acquisition in each sequency, with the AI MULT PT. But with this, I think that I will lose the precision of the sampling frequency. And I have to know the sampling fre
    quency ...
    Thanks for your help !
    Carline

    Hi Carline,
    A PCI-6034E is a low-cost board, which only has one Analog to Digital Converter (ADC).
    With only one ADC you can't acquire different channels at the same time. That's why you find a multiplexer before the ADC in this type of board. This enables you to acquire multi-channels at the same rate quasi simultaneously. The samples of the different channels will be interleaved as it is explained in the following knowledge base :
    - http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/9379ea091c264b7c86256bc90082ca5d?OpenDocument.
    With this method, the sampling frequency is the same for all channels. The sampling frequency of one channel is determined with the "scan rate" parameter. There is only a small delay between the samples
    of each channels. When you perform an interval scanning acquisition, this delay depends on the "sample rate" that you specify. To have more informations about this terminology, please refer to the following KBs :
    - http://digital.ni.com/public.nsf/websearch/4D1435DF82EF494186256D8A006DD6D4?OpenDocument.
    - http://digital.ni.com/public.nsf/websearch/4D1435DF82EF494186256D8A006DD6D4?OpenDocument.
    To easily perform such a multi-channels analog acquisition, you can use the VI named "AI Acquire Waveforms.vi". You also can use an example provided with LabVIEW. You just have to browse the NI Example Finder in "Harware Input & output >> Traditional NI-DAQ >> General".
    Best regards,
    Benjamin
    National Instruments France

Maybe you are looking for

  • Macbook to Sony Bravia - Problems

    Hey - So I'm trying to connect my Macbook (I got this back in like 2006-2007?) to my Sony Bravia TV. I have the current set-up: VGA Cable connected from the back of the TV to a Mini-DVI-to-VGA connector to the MacBook. When I plug it in, the Macbook

  • HT5012 How do I get the meddle button to work on my iphone

    How do I get the meddle button to work on my iPhone

  • Open documents

    Hi everyone, Is there a way to open any type of document and to display to the user ? How can I do it ? Thanks.

  • Siri bug reporting?

    How can one submit a bug report for Siri?  Below for your review - this is sort of important, I think... Note that Siri is saying "Street Agnes Hospital" instead of "Saint Agnes Hospital" - therefor she finds nothing. If I search for baltimore hospit

  • LOGIC PRO; with Macbook or Macbook Pro???????????????????????

    Hey!!!! Just wondering if you could help me. I 'm hesitating to buy MacBook or MacBook pro to use the LOgic Pro7. My question is; do you think that with the MacBOok will work properlly, or not? Do I need to buy the MacBook Pro? Please, help me becous