Error 200745 occured at DAQmx

Hello everyone.
Does anybody knows about this "error-200745 occured at DAQmx"
everytime I used 57.6KHz frequency and Initial delay of 1.
Looking forward of your help..
thanks and regards,
Ludz

Hi Ludz,
Do you get the error for every duty cycle?  Do you know which frequency or frequency range the program will give you this error?  What example program did you start with? One example you can try is the PWM-Counter Output.vi located in the example finder.  You can find the example finder at Help>>Find Examples.  When this opens, select the search tab in the top left and search for PWM.  I would try running this example with the same settings as your other program to see if you see the same behavior.
Regards,
Jim Schwartz

Similar Messages

  • Error -200587 occurred at DAQmx Start Task.vi:7

    I am running the attached code Merrit_Coil_calibration, and I get the following error:
    Error -200587 occurred at DAQmx Start Task.vi:7
    Possible reason(s):
    Requested operation could not be performed, because the specified digital lines are either reserved or the device is not present in NI-DAQmx.
    It is possible that these lines are reserved by another task, the device is being used through the Traditional NI-DAQ interface, or the device is being reset. You might also get the error if the specified resource is currently in use by LabVIEW network variables bound to the DAQ Channel, or if the DAQ Channel is being used in any OPC Client software.
    If you are using these lines with another task, wait for the task to complete.  If you are using the device through the Traditional NI-DAQ interface, and you want to use it with NI-DAQmx, reset (initialize) the device using the Traditional NI-DAQ interface. If you are resetting the device, wait for the reset to finish.
    Device:  Dev2
    Task Name: _unnamedTask<F>
    I am calling the same DAQ, many different places in my code and I think that is the problem, but I can not figure out why or hw to fix it.  Anyone have any suggestions?
    Attachments:
    Final.zip ‏2434 KB

    Thank you both for your input.  I slightly changed my code to Merritt_Coil_calibration (updated code attached) and the first error went away, but now I have a different one which is:
    Error -200429 occurred at DAQmx Write (Digital U32 1Chan 1Samp).vi:1
    Possible reason(s):
    Value passed to the Task/Channels In control is an empty string (or I/O control).
    The value must refer to a valid task or valid channels.
    As far as what DAQ device I am using, it is the NI USB 6009.  I am only using digital port 0.  During different pieces of my code I send different values to port 0.  I am using this to drive some stepper motors.  I thus send square waves on the different pins on port 0.  I do not know if this is exactly what you were asking. 
    Whatever the case, I was wondering if anyone knows why this error occurs and how I could fix it. 
    thanks.
    Attachments:
    honorsproject.zip ‏256 KB

  • Error-200220 occurred at daqmx create channel %28AO-Voltage-Basic%29.vi%3A3

    Hello  
    i need u r help  this  error apeears to me when i run my code on labview 
    and i dont know how i can solve it due  am still wake and dont have background on labviw 
    and coding 
    (error-200220 occurred at daqmx create channel (AO-Voltage-Basic).vi:3)

    ok the first problem is solved...
    but now in the another program
    its appearing:
    Error 1 occurred at Read File+ (string): Read File
    Possible reason(s):
    LabVIEW:  An input parameter is invalid. For example if the input is a path, the path might contain a character not allowed by the OS such as ? or @.
    =========================
    NI-488:  Command requires GPIB Controller to be Controller in Charge.

  • Error 229771 occurred at DAQmx Start Task - only in Labview project

    Labview 2011 sp1
    os: W7 32bits
    DAQmx 9.7.0f0
    ni-PCI 6251
    Hi,
    I'm working with a ni-PCI 6251 card. I got the error :  Error -229771 occurred at DAQmx Start Task. Possible reasons :Internal sofware error  occured in MIG software ... when I'm trying to launch my data acquisition vi. This error was already reported in this post :
    http://forums.ni.com/t5/Academic-Hardware-Products​-NI/Error-229771-occurred-at-DAQmx-Start-Task/td-p​...
    I tried to reinstall DAQmx as explained in the post but it unfurtunatly it did'nt fix my issue.
    I've notice the following points :
    1. This error appears randomly, after several reboots the vi will finally run without error
    2. The error only appears when the vi is included in project
    I will really appreciate any kind of help.
    sebastian
    Attachments:
    test_daq_2.vi ‏23 KB

    Bonjour,
    Je vous invite à jeter un oeil sur le lien suivant :
    http://digital.ni.com/public.nsf/allkb/03123D0E8A3​6C48E862577A4005B6BAA?OpenDocument
    Il devrait résoudre votre problématique.
    Cdlt,
    Matthieu RICORD
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    Été de LabVIEW 2014
    12 présentations en ligne, du 30 juin au 18 juillet

  • Error -200609 occurred at DAQmx Write: Selected Buffer Size Too Small

    Hello, I'm writing some simple test VI's that I will eventually build upon to make an externally clocked analog output VI. I started with a very simple program to output finite samples using the onboard clock with the DAQmx Timing.VI. When I run the program, I almost immediately get an error. The error message is below.
    Error -200609 occurred at DAQmx Write (Analog DBL 1Chan 1Samp).vi:1
    Possible reason(s):
    Generation cannot be started, because the selected buffer size is too small.
    Increase the buffer size.
    Conflicting Property
    Property: Output.BufSize
    Corresponding Value: 1
    Minimum Supported Value: 2
    Task Name: _unnamedTask<1C>
    I have used DAQmx VI's before in similar applications and never encountered this error. Additionally, I read at the link below that DAQmx Timing.VI should be generating the buffer automatically. Any ideas as what could be causing this?
    Specs:
    Windows 7
    Labview 2012
    PCIe-6353 as DAQ board
    Below is a picture of my block diagram and the VI is attached.
    Solved!
    Go to Solution.
    Attachments:
    FiniteSamplesTest.vi ‏18 KB

    Oops. Just realized my very silly mistake: I forgot to add the Start Task VI. I did so and it works as designed.

  • Error 200380 occurred at DAQmx perform bridge offset nulling operation

    I had a working VI that could balance a wheatstone half bridge and read and record measurements.  My sensors are attached to a SCXI-1314 modle in a 1520 box in channel 0 (positioned as in the manual for half bridge) with the completion resistors in the appt places in ch7.  It used 'custom voltage with excitation'.
    Wanted to improve this VI so that it would also do a shunt calibration.  I therefore connected the shunt resistor in the board over my active sensor as in the manual.  I tried then to create a virtual channel for it - but it wouldn't work.  So I gave up on that idea and tried to put things back how they were - deleted the virtual channel, and removed the connections to the shunt resistor.  Except now none of my previously working VIs will work.  I have built a new VI, and that can find a signal but not balance the bridge.  I get:
    error 200380 occurred at DAQmx perform bridge offset nulling operation.
    I have checked the hardware again, and it's all wired correctly - it seems like the VI can see the channel but doesn't know what to do with it.   Have running the VIs with and without a custom voltage with excitation channel created but nothing works.
    Help!

    Hi LucyWH
    Have you tried re identifying the chassis in Measurement and
    automation explorer?
    Have you changed the jumpers at all as when rewiring this is easily
    overlooked?
    I have found some links that you may find useful:
    Error -200380 When
    Calibrating SCXI-1520 in NI-DAQmx
    http://digital.ni.com/public.nsf/allkb/6E94108C9611910186256D43007C2584?OpenDocument
    Common NI-DAQmx Error
    Codes and Solutions: Codes -200300 to -200999
    http://digital.ni.com/public.nsf/allkb/8A0E097385A4269586256DBA0054E668?OpenDocument
    Regards
    Robert
    National Instruments UK & Ireland

  • Error -200220 occurred at DAQmx Create Channel (CO-Pulse Generation-Time).vi:1

    Hello,
    Just a couple of days ago I was given a task to complete. To transfer a Labview program from a desktop computer to laptop.
    The program itself uses a marlin camera to count the number of seeds.
    The transfer was fine I installed Labview 8.2, installed the DAQmx drivers and labview vision.
    I then transffered the program files over and ran the program on the laptop in labview and found an ERROR: Error -200220 occurred at DAQmx Create Channel (CO-Pulse Generation-Time).vi:1
    I remember that the desktop had a kind of board attached to it: some NI board dont know the model etc.
    can this be a problem? I have ensured that the problem is not the camera by checking it in MAX and it works fine.
    When i do step by step debugging the problem comes to a VI that uses a palette called DAQmx trigger - data acquisition palette.
    please see the attached picture!!
    Is this VI the problem then and is this palette the main problem that is not enabling this program to work??
    thankyou
    p.s. Will it be necessary to use the NI board then? if so i dont think it will work on the laptop then as you will need to install the daq card
    which can only be done on a desktop i think!! 

    Hello Rob W,
    Yes I only use a Firewire to connect the camera.
    And also i am sure that the device shows up in MAX under NI-DAQmx devices and not under Traditional DAQ. and it works under max.
    I am sure the problem is as shown in the image. because i have not connected to the NI board on the laptop and the program is designed to work with the board.
    but i have also tried removing the parts in the program that use the board but because of the complexity of the program i.e. wires i had some other problems i think
    must be the wiring etc
    thankyou

  • Error-50150 occured at DAQmx Write

    Hello,
        I am experiencing a seemingly random error in a large program. The error occurs in a part of the program that simulates tach signals to a CPLD. I have not been able to find out what conditions cause this error, it seems to be random in nature.
    The full error reads this:
    Error - 50150 occurred at DAQmx Write(Digital 1D U16 1Chan Nsamp).vi
    Possible Reasons:
    The software has entered an unknown state-usually as a result of a cascade failure induced by an unexpected series of state inputs. The operation could not be completed as specified and you should immediately terminate all further transactions if you are able to do so.
    Task Name:TackABC_Write Port0 U16
    The device we are using is a PCI-DIO-32HS, with Labview 7.1, NI-MAX 4.1, and DAQmx drivers 8.3.1. The task writes 3 signals to the CPLD, and it works most of the time, but every so often this error will occur. I was wondering what could be the cause of an error like this?
    Thanks, Steve

    Hello Brian, thanks for the response.
    I made a mistake in my last post, it is actually a DAQmx clear task in place of the stop task vi i mentioned. When we first received this error it had no clear task at the end, but I added one. Even with this the error has still shown up from time to time. Would it help at all to add a reset device vi afte the clear task vi?
    I took some screenshots for you as well. The first shot is of the function in question, the second is the same shot with the case turned to false, and the third is the inside of the main subvi. When the error occurs it focuses on the write vi that is inside the subvi. Let me know if there is more info I could grab that would make things mroe clear.
    Thanks,
    Steve
    Attachments:
    SS3.JPG ‏160 KB
    SS1.JPG ‏189 KB
    SS2.JPG ‏181 KB

  • Error -201003 occurred at DAQmx Create Channel (AI-Temperature-Thermocouple).vi:4

      I get this error when using the NI USB-TC01 LabVIEW Temperature Logger and a J type thermocouple.
    So I tried creating my own VI, the daq assistant gives me a correct reading but only for 1 sample. If I try to change to continous or N samples it will then give me this error:
    Error -200077 occurred at DAQ
    Assistant
    Possible Reason(s):
    Requested value
    is not a supported value for this property. The property value may be invalid
    because it conflicts with another property.
    Property:
    SampTimingType
    Requested Value: Sample Clock
    You Can Select:
    On Demand
    What Is the problem?? I need to get a continous reading that I can use through a VI to get an excel file with  the data. I also need it to be continous so I can manipulate the sampling rate.
    By the way I also tried using the device on other computers and it still gives the same problem.
    Julian Sanchez
    Mechanical Engineering Student - University of Central Florida
    Research Intern | CASER
    C. 407.744.4174 | E. [email protected]

    Thank you for your reply,
    I am new to LabVIEW and I am not sure how to do what you explained. The DAQ assistant has a "number of samples" when you drag the bottom; is that where I need to create the loop??
    What is the maximum # of samples per second that I can get with this device?? That is my ultimate goal with this experiment, to be able to get the most readings per second.
    Julian Sanchez
    Mechanical Engineering Student - University of Central Florida
    Research Intern | CASER
    C. 407.744.4174 | E. [email protected]

  • Error -200220 occurred at DAQmx Create Channel (AI-Voltag​e-Basic).v​i

    I am trying to set up my PMT using NI-DAQ 7.3 along with Labview 7.1.  I keep getting an error message described above.  I am new to this program, so I am not sure what is wrong.  I have also received an error message stating the device could not be routed.  Any ideas?  Thanks

    Hello WayneState,
    Welcome to the NI Forums. The error message should say something like this "Possible reason(s): Measurements: Device identifier is invalid." This means that the name of your device was incorrect. You should use the drop down box to select the one is configured in Measurement and Automation Explorer (MAX).
    There is very valuable information in this site since it is designed for people starting with data acquisition using our products.
    Finally, I see you have other problems in this LabVIEW thread that suggest that you have already overcome the error in this Thread. If so, please post back your description of the resolution and if not, please feel free to post back some screenshots of MAX and LabVIEW.
    Gerardo O.
    RF Systems Engineering
    National Instruments

  • Error -200428 Occurred at DAQmx Write (Digital Bool 1Line 1Point).vi

    The working program started giving this program after we have had a hard_disk crash. We are just using the program that was backed up. Will appreciate any suggestions on this one. 
    Naresh

    Have you read the explanation for the error and did you verify the task or virtual channels exist?

  • Error in Error -200485 occurred at DAQmx Create Task.vi:2

    I keep having this error: 
    The specified task cannot be loaded, because it is not in Data Neighborhood.
    Check Data Neighborhood in MAX. Look for similar characters, such as the capital letter "O" and the number zero.
    I would like to know what is the problem with the program.  I've attached the VI.
    Basically i am trying to control a physical LED connected to the NI Elvis II by comparing the inputs from DIO 0-7 and DIO 8-15.
    So if DIO 0 is on, DIO 8 must also be on to turn on the LED. 
    But at the moment, the program cant run. Need help in spotting the mistake! >< Thanks!
    Solved!
    Go to Solution.
    Attachments:
    Untitled 2.vi ‏94 KB

    From the code you attached I guess you haven't created a task (This is used to configure which is input and which is output) so you can take a look at the page how to create a task and go ahead.
    Good luck
    The best solution is the one you find it by yourself

  • How do I use two DAQ cards in one Labview code? Current I'm getting error " error 200558 occurred at DAQmx Create Channel.vi. One task cann't contain multiple independent devices". Can someone help me?

    The two DAQ cards are NI PCI-6070E & NI PCI-6052E. The Labview I'm using is labview 7 Express and the Window system is Window XP. I'm using NI SCXI-1000 chasis and SCXI-1102 & 1102B two modules plus a feedthrough SCXI-1180. 1102 is connected through SCXI-1349 cable to DAQ card 6052E while 1102B is connected through SCXI-1349 cable to DAQ card 6070E. SCXI-1180 is connected to 6070E through SCXI-1349 adaptor on the back of 1102B.

    Sarah, thank you for replying my question. It seems that I'm making progress everyday (smile). I'm able to run the test using both daq cards in my code now. But as I'm moving forward, I'm getting new questions too. How do I use one STOP button to control both tasks and how can I save data into one single file?
    I attached my code here hoping you can get the specifics on my application by looking at the code. Thanks very much!
    Thanks.
    Attachments:
    DAQmx_Task_Example_plus_voltage_2.vi ‏416 KB

  • Error -50103 occuring in one program, but not occuring in another similar program

    Hello,
    I'm a new user of LabView and I'm trying to figure out how a part of this programming process works.  Anyway, the block diagram of the working program consists of the first two pictures (C:\Users\Labview\Pictures\errorsetupnew1.jpg  -and-  C:\Users\Labview\Pictures\errorsetupnew2.jpg).  The parts in question are the DAQAssistant9 and DAQAssistant12 in the lower half of the diagram.  When I run the program, everything goes fine.
    So now I'm trying to run two other programs that both share the same properties as these two DAQAssistants, but they are in two separate programs.  When I run one program, it works, but when I run the other program, Error -50103 occurs at DAQmx Control Task.vi:10.  Pressing continue yields Error -50103 occuring at DAQmx Read (Analog 1D Wfm NChan NSamp).vi:3. 
    So my first attempt at solving it was to consolidate it into one program and run it all together, however the same error shows up.  I isolated the two While loops which seem to be causing the problem into a test program (third picture) and the error occurs there as well. 
    My question is what is different from the program in the first two pictures that is allowing the program to run correctly and the test program (which can be extended to the program that I need to work).
    I'm new, so please let me know how many beginner mistakes I might be making here!
    Thanks
    Attachments:
    errorsetupnew1.jpg ‏137 KB
    errorsetupnew2.jpg ‏113 KB
    errortest.jpg ‏82 KB

    I'm not currently at the computer with the files in question, but what if I attached those instead when I got the chance?  The problem is that I don't believe I am using the same DAQ resource in two different tasks.  The command line runs correctly in one, but can not run in the other even though the part giving the error is just a copy of the other program.
    I'm trying to run through the previous posts about this particular error but the LabView lingo is something I'm still getting used to.  Thank you for bearing with me and helping.

  • Error code -88708 with DAQmx Create Channel (AI-Voltage-Basic)

    Hi,
    I am trying to construct a VI that moves a piezoelectric stage, the VI then needs to scan voltages from the DAQ card to build up arrays of the voltage and coordinates before constructing a 3D graph.
    The VI successfully moves the stage and reads the position back to me but when it tries to scan voltages from the DAQ it fails (I'm using the DAQmx Create Channel (AI-Voltage-Basic).vi example, as this has been used in a previous, similar (and successful) VI within my department.)
    I get the following error code:
    Error -88708 occurred at DAQmx Create Channel (AI-Voltage-Basic).vi
    Possible reason(s):
    The specified resource is not available. The operation could not be completed as specified.
    Task Name: _unnamedTask<1>
    Any help on this would be appreciated - I'm fairly new to LabView and am at a loss with how to fix this!
    Thanks
    -Tom

    Is this working when you restart the computer? It might be that the recources are still recerved because the Clear Task.vi wasn't executed (either it`s not present or you did use the abort button).
    Felix
    www.aescusoft.de
    My latest community nugget on producer/consumer design
    My current blog: A journey through uml

Maybe you are looking for

  • How to find registered e-mail address for my skype...

    Hello, I need your help, because I'm unable to find associated email address for my father's skype account. After changing his computer we are not able to login again. Is there an option to use registered phone number in order to veify his identity a

  • IPod connected and read by MyComputer buy not iTunes...how do I restore?

    I was getting the frowning iPod and the triangle with the ! in it. I did the reset which did nothing. Then I did the play/select reset which put it into disk mode. I connected to the laptop. Now I get a Do Not Disconnect with a flashing circle with a

  • Monthly planned price in KP26

    Hi Experts, Could any of You pls help me how to handle monthly changed price in KP26! I would like to change and set planned activity price 4 times in a Year (per each Q), but If I simply enter the different prices in KP26 - the system calculates a s

  • ITunes cannot access files from home network

    Just got new Vista PC. All my music files are on older XP PC. I have set up my home network, and Vista PC can see/access all my XP folders. I have Sonos and Yahoo Jukebox installed on Vista PC and both programs can access the XP music files and play

  • Link to download DTW in marketplace

    Hi, I've been looking to download DTW for my SAP - 2005A (6.80.320) SP01 PL39. If I do a search for DTW in SAP Software Distribution Center, all I got is DTW 1.1 and 6.5. Based on their description, these files are just upgrades and patches. But I do