Error 2101 Detection error on HDD2 (mini sata) X220

running 1.40 biosthink I have WWAN model as there is a SIM slot and there are a red and blue wires ready for the 3G wireless card.all lenovo drivers etc checked to latest versionsInstalled 128GB Kingspan which failed to do anything and caused the whole system to be unbootable. Turns out the ssd was dead as it did not work in working usb enclosure.swapped in 64GB msata minipci from my old eee901 it is the correct size for the lenovo slot - it wasn't for the 901 and I am now getting 2101 Detection Error on hdd2 on boot up.I have tried reseating the card, cleaning the pins, reseating, booting to Hirens, Slacko, Gparted, Fedora and not been able to see it as the error code is pre OS... Anything I can do? - roll back drivers, roll back bios, buy specific brand msata any suggestions welcome :-)

Ram speed is not the issue I mentioned the speed purely in response to
comment relating to the bios and ram speed.
Because i would like to multiboot I would like to get an ssd to run in the
msata slot, which is currently empty. I bought a 128GB Kingspan ssd that
did "nothing" in the slot and refused to even let the x220 boot (I tried
booting from the ultrabase and from the laptop) i tried reseating the ssd a
number of times but the laptop would not boot with it in the msata slot.
And the Kingspan ssd did nothing in a working external msata enclosure and
is being returned.
I have an old m-factor 64GB ssd from my eee901 (with 2 or 3 mixed format
partitions on it) and I tried that in the x220 at which point I received
the 2101: Detection error on hdd2. I tried reseating the ssd to no avail
and tried cleaning the contacts with rubbing alcohol and reseated it but
still keep getting the error.
What I do not know is if the x220 is a wwan model does it need a specific
brand of msata ssd to work in the slot? E.G. the Intel 80GB + that are
mentioned in the forums.
Re Bios: According to the readme file attached to the older bios versions
that are available from lenovo there were some fixes for the wwan models
that related to the ssds which is why I asked about rolling back the bios
in the hope that an earlier bios might work the ssd in the msata slot.
(Rather as the later bios restricts the speed of the ram...)
Thanks again for all of your help. I'm new to messing around with the x
series and don't know all of the quirks etc :-)

Similar Messages

  • T450s Thinkpad - ERROR 2101: Detection error on SSD1 (M.2)

    Model: T450sEquiped as:Intel i54+4GB RAM256GB SSD (M.2) Configured as boot disk running Win 7 x64500GB HDD as additional storage Issue:Seemingly at random, approx once every one to two weeks while PC is on and at the desktop but not actively being used (meaning no user is sitting in front of it performing tasks) it will error and crash.  The error is a black screen with the following error: 2101: Detection error on SSD1 (M.2) Press Esc to continue. According to the user Esc does nothing and the only escape is to long press the physical power button until a power down occurs.  On reboot the system comes up without issue.  No user has actually seen the crash take place.   MY QUESTION(S):1st.  Is this most likely an issue with the T450s not being able to reliably boot from the m.2 slot or is this more likely an issue with the SSD installed in the m.2 slot?2nd.  Is this something altogether different?  Any (knowledgeable) advice or info appreciated.

    It is hard to diagnose without seeing it, but my experience has been that the Gen4 and later CPUs (like yours) support a very low power state that is incompatible with some devices. (that would make it a problem with the card) Make sure you have the latest BIOS and power manager software installed. Look in the device manager and find the M.2 SSD. There should be a power management tab. Turn off the option to allow the system shut the device off to save energy.

  • W520: PNY XLR8 240GB SSD with error "2100: Detection Error on HDD0 (Main HDD)"

    When I try to boot my W520, I get a BIOS boot up error : "2100: Detection Error on HDD0 (Main HDD)". I am using PNY XLR8 240GB SSD.
    It worked fine for a month.
    I also have PGP installed and whole disc encrypted.
    I installed an update of Intel Management Engine Firmware and Intel Chipset, both are the latest from lenovo site because I was experiencing expreme slowness from my harddrive. Programs would freeze. Webpages would take forever to load..
    The next time I rebooted, I got the error. If I leave the SSD out for a bit, and put the SSD back in, the disk will work for some time... but on next reboot, it is again detection error..
    TRIM is enabled on my system. I am not sure how the SSD died so quickly.
    I am back to using my HDD but I am not happy. I want a solution... is this a intel chipset issue? Intel IMEI issue? Is  the PNY SSD just a bad model?
    I've googled plenty and dont really see a solution. Sometimes there is a firmware update.. PNY has no firmware updates for my drive.. I don't see anybody else using PNY on their W520, but plenty of people are experiencing Error 2100 with SSD on their W520.. somethings fishy..
    help please! thanks in advance !

    No go, the drive is in there pretty firmly, a tech support to PNY said they are going to replace my drive.
    They came to the same conclusion I did - which is that the drive is toast..
    Drive slow downs and eventually unable to detect points to this.. I was hoping for some firmware update. I am really surprised an SSD died because I thought the whole point of them - no spinning parts - would make them last longer.. but there is some sort of logic board and maybe the flash drive itself went kaput.. who knows. 
    They do have 3 year warranty on my mode and i'm happy to take it. Luckily my old HDD was still around and works.. so thats what i'll be using for the next few weeks while I ship this to them and have them send me a new one.
    I asked about Advanced replacement, which is when they send me a new one before they recieve my current ssd. They said the Advanced replacemenet costs $30, and they would need credit card info to place a charge of the original amount for the drive incase I didnt send in the drive too. So it would cost me $30 plus temporary $100-150 or so... which I opted not to do... So I wait now for a few weeks. I dont know if I'll get another PNY drive in the future. OCZ has faired pretty well for me, I've had 3 of them work on desktops/laptops flawlessly. 

  • 2101 detection on HDD2 (mini sata) error on my T430

    I got this error out of the blue the other day on startup, and now I get it every time I restart.  I have tried a number of solutions that I found in these forums (which I'll outline below) but it seems like my system just can't find the drive anymore. 
    Here's what I've done:
    1. ran the ExpressCache program via Command Prompt (eccmd.exe -info) and got this error:  "**ERROR** ECCmd Request device is not available"
    2. unistalled the ExpressCache software, shut down, pulled the battery opened up the memory module slot cover, removed the mSATA drive and then re mounted it.
    3.  reinstalled ExpressCache
    4.  I'm trying to reformat the drive, but I am receiving similar errors
         a.  When I try to format the drive (eccmd.exe -format) I get the following error:  HFS Volume is not mounted  **ERROR**  ECCmd Requested device is not available
         b.  When I try to create a partition (eccmd.exe -partition) I get the following error:  0x10df (4319).  I looked this up and maybe there are system files missing?
    I have also tried this but it then says "There is NO mSATA detected, please check mSATA attached" http://support.lenovo.com/en_US/research/hints-or-tips/detail.page?DocID=HT073737
    If anyone has any advice, please let me know.

    Hello and welcome,
    None of the symptoms you describe sound to me like software issues. There is something wrong with the mSATA SSD, or the controller that accesses it - or it needs to be re-inserted in its socket.
    Is this machine under warranty?  I'd suggest calling support and running this by them.  They may suggest re-seating the device in its socket, or may offer replacement or some other option.  I don't speak for Lenovo, just offering my personal suggestion.
    Z.
    The large print: please read the Community Participation Rules before posting. Include as much information as possible: model, machine type, operating system, and a descriptive subject line. Do not include personal information: serial number, telephone number, email address, etc.  The fine print: I do not work for, nor do I speak for Lenovo. Unsolicited private messages will be ignored. ... GeezBlog
    English Community   Deutsche Community   Comunidad en Español   Русскоязычное Сообщество

  • 2100: Detection error on HDD0 (Main HDD)

    I have a Lenovo ThinkPad Yoga, with a 256GB SSD and an i5 processor.
    I received it on April 29. After two weeks of normal use, it crashed and gave this error:
    “2100: Detection error on HDD0 (Main HDD)”
    I could not get it to boot. I took it to a computer repair shop and they (Lenovo warrantee) replaced the SSD. It worked for about a week, then crashed again, same error. My tech guy said that it might be a bad board, frying hard drives; but Lenovo insisted on replacing the hard drive again. Ten days later, same crash. I unplugged it and put it on a shelf for the weekend, intending to take it back to the shop. Monday morning I plugged it in and it started up normally.
    It has been working normally for three days, but I am worried about getting the same error and crash. Can you tell me what might be happening, and if there is anything I can do to prevent a recurrence?
    This seems to be a common problem across many machine models, but I haven't found any solutions to it.
    Solved!
    Go to Solution.

    Thanks!
    Funny, my post was dated 7/15/2014.  That article is dated 7/17/2014.  Someone might be listening
    http://support.lenovo.com/en_US/detail.page?DocID=HT082504
    Will test it out, hopefully it works.
    -Sloppy

  • MD3000 Drive detected errors is increasing

    Hi,
    we are using md3000 with sas connection.
    since some days, we are facing big performance issues.
    the system is running with 15 drives:
          TRAY, SLOT  STATUS   CAPACITY    TYPE  CURRENT DATA RATE  PRODUCT ID                                FIRMWARE VERSION
          0, 1        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 2        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 3        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 4        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 5        Failed   931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 6        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 7        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 8        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 9        Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 10       Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 11       Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 12       Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 13       Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 14       Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
          0, 15       Optimal  931.513 GB  SATA  3 Gbps             Hitachi HUA722010CLA330                   JP4OA3JH
    here the information on disk 5:
    Drive at Enclosure 0, Slot 5
       Status:                  Failed
       Mode:                    Assigned
       Raw capacity:            931.513 GB
       Usable capacity:         931.013 GB
       World-wide identifier:   50:00:cc:a3:9a:c7:9f:50:00:00:00:00:00:00:00:00
       Associated array:        md3000g0
       Drive path redundancy:  Lost
       Drive type:             Serial ATA (SATA)
       Speed:                  7,200 RPM
       Current data rate:      3 Gbps
       Product ID:             Hitachi HUA722010CLA330
       Package version:        JP4OA3JH
       Firmware version:       JP4OA3JH
       Serial number:          JPW9P0N00JSU2D
       Vendor:                 Not Available
       Date of manufacture:    Not Available
    it is already replaced by hotspare disk 13 and the array is in optimal status.
    but the error counter is still increasing:
    DRIVE CHANNELS----------------------------
       SUMMARY
          CHANNEL  PORT       STATUS   
          1        Expansion  Optimal  
          2        Expansion  Optimal  
       DETAILS
          DRIVE CHANNEL 1
             Port: Expansion
                Status: Optimal
                Max. Rate: 3 Gbps
                Current Rate: 3 Gbps
                Rate Control: Switched
                DRIVE COUNTS
                   Total # of attached drives: 15
                   Connected to: A
                      Attached drives: 15
                         Drive enclosure: 0 (15 drives)
                CUMULATIVE ERROR COUNTS
                   Controller A
                      Baseline time set:               4/2/15 9:15:42 AM  
                      Sample period (days, hh:mm:ss):  33 days, 03:07:36  
                      Controller detected errors:      9                  
                      Drive detected errors:           3640802            
                      Timeout errors:                  0                  
                      Total I/O count:                 31288381           
                   Controller B
                      Baseline time set:               4/2/15 9:15:42 AM  
                      Sample period (days, hh:mm:ss):  33 days, 03:01:02  
                      Controller detected errors:      8                  
                      Drive detected errors:           3512795            
                      Timeout errors:                  0                  
                      Total I/O count:                 754965630          
             DRIVE CHANNEL 2
                Port: Expansion
                   Status: Optimal
                   Max. Rate: 3 Gbps
                   Current Rate: 3 Gbps
                   Rate Control: Switched
                   DRIVE COUNTS
                      Total # of attached drives: 15
                      Connected to: B
                         Attached drives: 15
                            Drive enclosure: 0 (15 drives)
                   CUMULATIVE ERROR COUNTS
                      Controller A
                         Baseline time set:               4/2/15 9:15:42 AM  
                         Sample period (days, hh:mm:ss):  33 days, 03:07:36  
                         Controller detected errors:      0                  
                         Drive detected errors:           0                  
                         Timeout errors:                  0                  
                         Total I/O count:                 5708758            
                      Controller B
                         Baseline time set:               4/2/15 9:15:42 AM  
                         Sample period (days, hh:mm:ss):  33 days, 03:01:02  
                         Controller detected errors:      0                  
                         Drive detected errors:           0                  
                         Timeout errors:                  0                  
                         Total I/O count:                 247629779          
    do i have to "unassign" the disk 5 or how to find out, where these "Drive detected errors" come from?
    thanks.
    patrick

    Somya, check your parameters:
    1 * Last added file name (lastfile) ....... [I:\ORACLE\SMD\SAPDATA2\SR3_11\SR3.
    DATA11]
    2 * Last added file size in MB (lastsize) . [<b>420</b>]
    3 - New file to be added (file) ........... [I:\oracle\SMD\sapdata2\sr3_12\sr3.
    data12]
    4 # Raw disk / link target (rawlink) ...... []
    5 - Size of the new file in MB (size) ..... [420]
    6 - File autoextend mode (autoextend) ..... [yes]
    7 - Maximum file size in MB (maxsize) ..... [<b>10000]</b>
    8 - File increment size in MB (incrsize) .. [<b>20</b>]
    option 2: your datafile will use 420MB to begin with.
    option 7: it can grow up to 10000MB
    option 8: it will grow with increments of 20MB
    so, you need at least 10GB in your filesystem.
    your warnings are saying that datafiles of 3 tablespaces, if they grow to their maximum file size, will overflow your filesystem (PSAPSR3,PSAPSR3700,PSAPSR3DB).
    solutions:
    1. increase filesystem size
    2. decrease value of maximum size of datafiles, I would especially check the maximum size of ALL datafiles of PSAPSR3.
    3. move some datafiles on another filesystem.
    good luck.

  • 2100: Detection error on HDD0 (Thinkpad Yoga)

    I have a Thinkpad Yoga which today was turned on while I was away (i.e. computer was not in use). When returning back the screen said "2100: Detection error on HDD0 (Main HDD)". Windows must have crashed (probably just another one of those faulty Lenovo drivers) and then the system couldn't boot up.
    Everything seems alright after a hard reboot but I'm afraid my SSD drive has gone bad.
    Link to image
    Found a support document of the error on Thinkpads with Samsung SSD, but mine have a LiteOn. Can anyone help me find out why this happened and if anything is wrong with my SSD?
    Thanks,
    // Måns
    The support document I'm talking about: http://support.lenovo.com/us/en/documents/ht082504
    Moderator note: large image(s) converted to link(s):  About Posting Pictures In The Forums

    Hi guys,
    had the same error and found out, that the cable from Motherboard to HDD controller was not plugged in correctly.
    After plugin correctly the error disappeared.
    Hope to help you.
    BR, David

  • X240 2100: Detection error on HDD0 (Main HDD)

    Hi all,
    I replaced original HDD on SSD 250 GB and formatted built-in Toshiba SSD-disk 20 GB . On 250 GB SSD installed Windows 8. And after turn on notebook I get "2100: Detection error on HDD0 (Main HDD). Press Esc to continue". If press "Esc" then there is boot menu, contain 2 point: ATA HDD2 Toshiba and PCI LAN. But after ALT+CTRL+DEL begins normal loading Windows 8.
    Any ideas why?

    Count me in... 
    Crucial M550 1TB SSD...
    It is fine after reboot, I got this laptop on Wednesday and just doing stability testing since this morning...
    I left home ~1pm with the Lenovo hardware testing software running, and came back ~7pm... not even half day...
    I just finished the same hardware testing, no 2100 yet... will leave it on overnight.
    My client is waiting for this laptop... I can't wait for replacement... either refund or firmware to fix it.
    Why is that so hard to get a decent PC laptop these days?! Even we are willing to pay for the money.
    EDIT:
    x240 config - Upgraded to
    8GB RAM
    Intel 7260 BT ACBGN
    X240 12.5FHD IPS MT WWAN
    X240 Intel i5-4300U

  • I'm getting this error statement: XULRUNNER error: platform version 6.0.2 is not compatible with min etc max etc6.0.1 - what is this about and how can it be corrected?

    This is what I think may have happened. The other day, Thursday Sept 8th, I shut down my pc in the middle of a Firefox upgrade. Now when I try to access Firefox on my pc, I get this error message:
    XULRUNNER Error: Platform version '6.0.2 is not compatible with min Version >= 6.0.1 max Version < 6.0.1
    What is this about and how can I retsore access to Firefox on my pc?

    If you use ZoneAlarm Extreme Security then try to disable Virtualization.
    Do a clean reinstall and delete the Firefox program folder.
    * http://kb.mozillazine.org/Browser_will_not_start_up#XULRunner_error_after_an_update
    *[[/questions/869812]]
    *[[/questions/869951]]

  • How to fix authentic error in game centre of iPad mini?

    How to fix authentic error in game centre of iPad mini?

    Following further research, this keyboard lag issue appears to be related to the (botched) iOS 7.1 update. It's good to know I am not the only user who had his iPad mini rendered unusuable by the iOS 7.1 update, however that does not solve my problem.
    Anyone out there who has further suggestions (except doing a factory reset via iTunes)?

  • How can I configure ReFS to NOT fail read operations when a checksum error is detected (on non-Storage-Spaces volumes where data integrity streams are enabled)?

    According to William Stanek, in his Windows Server 2012 R2 Inside Out: Configuration, Storage & Essentials book, this is apparently possible: (pg. 615 - here it is on Google Books: https://books.google.ca/books?id=0IyfBAAAQBAJ&pg=PT819&lpg=PT819&dq=read+operation )
        Integrity can be enabled when the system is not running on Storage Spaces. When
        integrity is enabled and ReFS detects a checksum mismatch, ReFS logs an event and
        fails the read operation by default. If you don’t want the read operation to fail, you
        can configure ReFS to continue with the read operation. A related event will be logged
        regardless.
    So then how do I configure it to do that???
    (And just to make it super-clear, I'm NOT using Storage Spaces, so there is no redundancy via mirroring/parity, and I'm not expecting any file repair - just detection of corruption. It's just a basic volume formatted with ReFS and
    with integrity streams enabled, via format E: /fs:ReFS /i:enabled
    For those who want more details, here's the situation: 
    I try to perform a read operation on a file with corrupted data (purposely done for testing using a low-level disk editor), I get a the following error message:
    And an event ID 133 from ReFSv1 gets logged in the System log:
    Clicking "Try Again" just brings up the same message, and clicking "Skip" skips the operation entirely.
    This is indeed the correct default behaviour.
    What I want instead is for the read operation to be allowed to complete, with corrupt data and all, and ONLY for the event to be logged. And according to William Stanek, this is supposed to be configurable somewhere - and after hours of searching, I haven't
    been able to find anything.

    Hi Tommy,
    >>How can I configure ReFS to NOT fail read operations when a checksum error is detected
    We can use PowerShell command Set-FileIntegrity to configure this. The specific parameter for controlling this behavior is
    -Enforce <Boolean>which indicates whether to enable blocking access to a file if integrity streams do not match the data.  
    Regarding this point, the following article can be referred to as reference.
    Set-FileIntegrity
    https://technet.microsoft.com/en-us/library/jj218351.aspx
    Best regards,
    Frank Shen
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Solution - Battery error is detected. Irreparable damage to the battery has been detected. Replace

    I own a T61 7658 I bough on 2008, it worked great with the default power settings until October 22nd I decided to change my power profile to MAXIMUM PERFORMANCE.  
    Next day I received on Message Center...
     10/23/2010 - Battery health is critical. With the current system settings and a full charge, your battery can provide approximately 3.0 hours of use. A new battery could provide up to an estimated 5.5 hours.
    I kept using the Laptop with the Max performance until...
    11/12/2010 - Battery error is detected. Irreparable damage to the battery has been detected. Replace the battery with a new one. 
    I have used IBM/Lenovo  for years and even had used batteries for 5 years without a single issue.
    I have read many posts of people having the same problem not only with T61s, but many other Lenovo models, and also read posts of Lenovo's administrators suggesting this is normal and justifying that batteries should be good for at least 12 months and after that we are on own, basically meaning we should be thankful in name of our own safety that we had that battery protection and we must replace it at our own cost and forget about it.  That is a very easy way out, isn’t it.
    But certainly, not only batteries with more than 12 months are failing, even new batteries are and have been replaced with multiple exchange programs posted by Lenovo in their website just as in http://download.lenovo.com/lenovo/content/batt/082009/LandingPage.html. and also in multiple MIGR battery replacement campaigns available to all online as well. 
    Good thing here is that Lenovo has recognized the problem and has exchange the batteries still under warranty and also few of the batteries without warranty limiting to some serial numbers on the MIGR battery replacement campaigns, but the bad side is that Lenovo is leaving behind other clients like me and many others not being selected for replacement.  But I’m sure we all have a good battery but turned useless due to the Lenovo programmed safety temperature limits in the power manager and the battery board.  Please let me explain.
    This is my conclusion.  There is nothing wrong with used or new batteries or their cells in 99% of the cases, I'm sure my battery is okay although is being turned useless by the battery protection feature on my T61.
    Lenovo must recognize the problem is the settings they have programmed on the power manager and battery protection board. It is very understandable that when users select a Power Scheme that demands higher amounts of power to generate better performance on the system this also demand additional power generating heat on battery and on the power supply as the computer is running at full performance, just as happens on my ipod when watching video, or in my kid’s R/C truck when running continuously and will happen with any other battery powered device.  
    Therefore any scheme requiring performance is generating heat and is tripping the battery protection and this is not a client’s fault, as are we just using an available scheme provided on our Lenovo system. If the battery protection is not calibrated to support this power demand, then there is a poor design/testing of the capabilities of the system and the battery protection parameters that instruct the battery to save itself from a fire or burning … which is understandable. 
    The bad side is that there is not possible reset option for the end users, the only option is to buy a new battery at our own cost after the 12 months of warranty, when the cause of the problem is originated in the computer system design settings and can happen at any time, that is way, the system warned me, as in:
     10/23/2010 - Battery health is critical. With the current system settings and a full charge, your battery can provide approximately 3.0 hours of use. A new battery could provide up to an estimated 5.5 hours.
    The computer is saying! At maximum performance, You are using too much power, and my battery will last just 3 hrs (9 cells on my system) instead of the 5.5 hrs that should last. But not only the running time was reduced, the heat on the power supply system and Battery was also increased due to the higher power demand, the battery can not handle the demand and protect itself to prevent fire or damage.
    So who has to pay for this?  Can Lenovo do something about it? For us client and for future clients?  This not a matter of having or not having warranty, this can happen at any time in any computer.
    I'm writing this hoping to be heard and supported and I hope LENOVO provides a satisfactory solution to the issue.  I'm not going to say will never buy Lenovo again I already did, I invested my money on Lenovo and with warranty or not I'm looking forward to get a decent response.  
    Lenovo must change the parameters for tripping battery protection probably handled at BIOS level, and to provide a reset feature to all "locked" batteries there is many people that has lost at least one battery, some other more than that.  Since even if we get a replacement, the chances  the issue will continue is there, as long as I select a high power demand scheme the problem sooner or later will be back.   Even car makers support their clients beyond the warranty if they detect that the issue compromises safety and their reputation.  Fix it. 
    M.Padron.

    amtho, welcome to the forum,
    start by looking at this site and also look at this site which is actually linked to from the first one.
    Hope this helps
    Andy  ______________________________________
    Please remember to come back and mark the post that you feel solved your question as the solution, it earns the member + points
    Did you find a post helpfull? You can thank the member by clicking on the star to the left awarding them Kudos Please add your type, model number and OS to your signature, it helps to help you. Forum Search Option T430 2347-G7U W8 x64, Yoga 10 HD+, Tablet 1838-2BG, T61p 6460-67G W7 x64, T43p 2668-G2G XP, T23 2647-9LG XP, plus a few more. FYI Unsolicited Personal Messages will be ignored.
      Deutsche Community     Comunidad en Español    English Community Русскоязычное Сообщество
    PepperonI blog 

  • JSPM: Error while detecting start profile for instance with ID _c.

    Hi Experts,
    we have an error when we start JSPM with message "cannot initialize application data. Error while detecting start profile for instance with ID _c." . Until now nothing has been updated yet. The system can be started up and shut down without any problem. The profiles are found in /usr/sap/PMA/SYS/profile
    Our BI system is currently Netweaver 7.0 with SPS14. We plan to update it to SPS20. But when we start JSPM, we have abover error.
    could somebody give a help? Thank you very much.
    Rongfeng
    P.S. the log file DETECT_SYSTEM_PARAMETERS_01.LOG:
    <!LOGHEADER[START]/>
    <!HELP[Manual modification of the header may cause parsing problem!]/>
    <!LOGGINGVERSION[1.5.3.7185 - 630]/>
    <!NAME[/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/log/log_2009_11_18_10_28_50/DETECT_SYSTEM_PARAMETERS_01.LOG]/>
    <!PATTERN[DETECT_SYSTEM_PARAMETERS_01.LOG]/>
    <!FORMATTER[com.sap.tc.logging.ListFormatter]/>
    <!ENCODING[UTF8]/>
    <!LOGHEADER[END]/>
    #1.5^H#C000995FC0200000000000207BD47BD40004789C01294DB0#1258511336558#/System/Server/Upgrade/JSPM##com.sap.sdt.jspm.gui.InitialParametersDetector.initializeJspmDataModel(InitialParametersDetector.java:397)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.jspm.gui.InitialParametersDetector.initializeJspmDataModel(InitialParametersDetector.java:397)#Java###Initializing JSPM data model...##
    #1.5^H#C000995FC0200000000000217BD47BD40004789C01295968#1258511336561#/System/Server/Upgrade/JSPM##com.sap.sdt.jspm.gui.InitialParametersDetector.detectProfileDirectory(InitialParametersDetector.java:1468)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.jspm.gui.InitialParametersDetector.detectProfileDirectory(InitialParametersDetector.java:1468)#Java###Detected profile directory .#1#/usr/sap/PMA/SYS/profile#
    #1.5^H#C000995FC0200000000000227BD47BD40004789C0141AFE0#1258511338156#/System/Server/Upgrade/JSPM##com.sap.sdt.jspm.gui.InitialParametersDetector.detectDb(InitialParametersDetector.java:936)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.jspm.gui.InitialParametersDetector.detectDb(InitialParametersDetector.java:936)#Java###Detecting the parameters of the database...##
    #1.5^H#C000995FC0200000000000237BD47BD40004789C014205D0#1258511338178#/System/Server/Upgrade/JSPM##com.sap.sdt.db.dmtif.AbstractDMTController.execute(AbstractDMTController.java:261)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.db.dmtif.AbstractDMTController.execute(AbstractDMTController.java:261)#Java###Executing command with arguments .#2#dbinfo#/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/config/DBINFO.XML#
    #1.5^H#C000995FC0200000000000247BD47BD40004789C01421570#1258511338182#/System/Server/Upgrade/JSPM##com.sap.sdt.tools.proc.JavaOsProcessController.logProcessInfo(JavaOsProcessController.java:41)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.tools.proc.JavaOsProcessController.logProcessInfo(JavaOsProcessController.java:41)#Java###Java process ID , name has been started.#2#5#com.sap.sdt.dmt.main.DMT#
    #1.5^H#C000995FC0200000000000257BD47BD40004789C01421958#1258511338183#/System/Server/Upgrade/JSPM##com.sap.sdt.tools.proc.JavaOsProcessController.logProcessInfo(JavaOsProcessController.java:54)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.tools.proc.JavaOsProcessController.logProcessInfo(JavaOsProcessController.java:54)#Java###Command line: #2#  #/opt/IBMJava2-amd64-142/jre/bin/java -cp .:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/sdt_dmt.jar:/oracle/client/10x_64/instantclient/ojdbc14.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/jddi.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/opensqlsta.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/tc_sec_secstorefs.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/frame.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/exception.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/logging.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/jperflib.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/lib/util.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/./lib/tc_sec_secstorefs.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/./lib/exception.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/./lib/logging.jar:/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/./lib/opensqlsta.jar:/sapmnt/PMA/global/security/lib/tools/info/IAIKSecurityFS.list:/sapmnt/PMA/global/security/lib/tools/iaik_jce.jar:/sapmnt/PMA/global/security/lib/tools/iaik_smime.jar:/sapmnt/PMA/global/security/lib/tools/iaik_jsse.jar:/sapmnt/PMA/global/security/lib/tools/w3c_http.jar:/sapmnt/PMA/global/security/lib/tools/iaik_ssl.jar:/sapmnt/PMA/global/security/lib/engine/info/IAIKSecurityFS.list:/sapmnt/PMA/global/security/lib/engine/iaik_jce.jar com.sap.sdt.dmt.main.DMT -rootdir=/usr/sap/PMA/DVEBMGS10/j2ee/JSPM -descriptor=csrt29_PMA -logfile=/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/log/log_2009_11_18_10_28_50/DMT_01.LOG dbinfo /usr/sap/PMA/DVEBMGS10/j2ee/JSPM/config/DBINFO.XML#
    #1.5^H#C000995FC0200000000000267BD47BD40004789C01422128#1258511338185#/System/Server/Upgrade/JSPM##com.sap.sdt.tools.proc.JavaOsProcessController.logProcessInfo(JavaOsProcessController.java:55)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.tools.proc.JavaOsProcessController.logProcessInfo(JavaOsProcessController.java:55)#Java###Standard out: #2#  #/usr/sap/PMA/DVEBMGS10/j2ee/JSPM/log/log_2009_11_18_10_28_50/DMT_01_01.OUT#
    #1.5^H#C000995FC0200000000000277BD47BD40004789C01424838#1258511338195#/System/Server/Upgrade/JSPM##com.sap.sdt.tools.proc.OsProcessController.launch(OsProcessController.java:126)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.tools.proc.OsProcessController.launch(OsProcessController.java:126)#Java###Process ID has been started.#1#5#
    #1.5^H#C000995FC0200000000000287BD47BD40004789C014253F0#1258511338198#/System/Server/Upgrade/JSPM##com.sap.sdt.tools.proc.OsProcessController.waitFor(OsProcessController.java:182)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.tools.proc.OsProcessController.waitFor(OsProcessController.java:182)#Java###Waiting for process ID , name to finish.#2#5#java#
    #1.5^H#C000995FC0200000000000297BD47BD40004789C017402B0#1258511341454#/System/Server/Upgrade/JSPM##com.sap.sdt.tools.proc.OsProcessController.waitFor(OsProcessController.java:215)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.tools.proc.OsProcessController.waitFor(OsProcessController.java:215)#Java###Process ID , name has been finished, exit code .#3#5#java#0#
    #1.5^H#C000995FC02000000000002A7BD47BD40004789C01741638#1258511341459#/System/Server/Upgrade/JSPM##com.sap.sdt.db.dmtif.AbstractDMTController.execute(AbstractDMTController.java:273)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.db.dmtif.AbstractDMTController.execute(AbstractDMTController.java:273)#Java###Command has been executed.#1#dbinfo#
    #1.5^H#C000995FC02000000000002B7BD47BD40004789C017421F0#1258511341462#/System/Server/Upgrade/JSPM##com.sap.sdt.jspm.gui.InitialParametersDetector.detectDb(InitialParametersDetector.java:984)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.jspm.gui.InitialParametersDetector.detectDb(InitialParametersDetector.java:984)#Java###Detection of the parameters of the database has finished. Database type is , database name is and database version is .#3#ORA#Oracle#10.2.0.2.0#
    #1.5^H#C000995FC02000000000002C7BD47BD40004789C01744CE8#1258511341473#/System/Server/Upgrade/JSPM##com.sap.sdt.j2ee.tools.sysinfo.AbstractInfoController.updateProfileVariable(AbstractInfoController.java:284)#######Thread[main,5,main]##0#0#Info#1#com.sap.sdt.j2ee.tools.sysinfo.AbstractInfoController.updateProfileVariable(AbstractInfoController.java:284)#Java###Parameter has been detected. Parameter value is .#2#/J2EE/StandardSystem/DefaultProfilePath#/usr/sap/PMA/SYS/profile/DEFAULT.PFL#
    Sorry, I don't know how to format post 
    Edited by: Rongfeng Shi on Nov 18, 2009 4:20 AM

    Hi Rongfeng,
    There is not much information about the error in the log file you have pasted above.
    Please repeat the issue and catch the log files once again.
    Are you able to open SDM ?
    Best Regards
    Raghu

  • Error Message " An error occured while running the detection " Sharepoint 2010 & Project Server 2010

    i am trying to Update the Service Pack of sharepoint & Project
    Server (SP2) . i got an error while running the Package " An error occured while running the detection " ... I searched a bit and ran ROISCAN.vbs script which is by provided by MS to identify any issues ... i Found that few MSI files of sharepoint
    are missing from WINDOWS Installer folder.... My Question is Should i repair the Sharepoint or any tool that i can use to get the MSI ?

    There is a MS internal tool for fixing this issue but for this may be you need to contact MS, refer to below links:
    Utility Name: OPUtil.vbs
    http://social.technet.microsoft.com/Forums/en-US/a7919b10-e4fe-4911-9016-bb6b81cf4194/sharepoint-patch-update-issue
    http://blogs.technet.com/b/paulpaa/archive/2010/03/26/sharepoint-2007-hotfix-failed-with-an-error-the-detection-failed-this-can-be-due-to-a-corrupted-installation.aspx
    Please ensure that you mark a question as Answered once you receive a satisfactory response.

  • TS1843 I am getting the following error messages- No DNS Server and Double SAT.  Can anyone walk me through a fix?

    Airport Express- No internet connection. I am getting the following error messages- No DNS Server and Double SAT.  Can anyone walk me through a fix

    Try putting these numbers in Network>TCP/IP>DNS Servers, for the Interface you connect with...
    208.67.222.222
    208.67.220.220
    Then Apply. For 10.5/10.6 Network, highlight Interface>Advanced button>DNS tab>little + icon.
    Might also put them in the Airport Express, no idea what Double SAT is!?

Maybe you are looking for

  • Importfileinto fails PNG's on SOME computers WHEN on the internet (shockwave)

    hello; I have a shockwave that uses preloadnetthing/importfileinto to import various files (eg jpg's , png's , w3d's ); use my laptop as an example: - when in author mode ( Director 10 ) all files do as expected; - when on the internet, the png's dow

  • Tracing outbound delivery failures

    First, I hope this is the correct forum. I am looking at the Exchange Admin center for Office 365, which I believe is the same product as Exchange Online? I am trying to determine why outbound mail is not being delivered to a particular sender for on

  • How do I update my itunes to 10.5 or higher

    My Iphone will not update; an error always takes place when I try to update.

  • The flow of SD

    Hi Experts .     Can u please help me explain how the flow of SD  and MM, and In FI CO( what are the transcation will be created)

  • Img alt="text" not displayed when images are turned off in Safari

    I have tried to search this, but every search has returned too many posts, so I apologize in advance. Have I made some error or is there an issue with my Safari? For some reason my Safari does not display alt="text" when images are turned off? This i