Dear All,
when i click display on End-to-End Monitoring, and then not accepting any user etc and the following error message come up
Logon failed error
Call of URL http://sapxi:50010/sap/bc/bsp/sap/spi_monitor/monitor.do terminated due to error in logon data.
Note
Logon performed in system XID .
Logon performed for client 100 and language EN.
What can I do?
Check the validity of your SSO ticket for this system.
If you do not yet have a user ID, contact your system administrator.
error code: ICF-LE-http-c:100-l:3-T:21-C:3-U:5-P:-L:7
HTTP 401 - Unauthorized
Please help.
Regards,
Venkat.

Dear All,
As per your suggestion,I have used PIRWBUSER,
In Runtime Workbench -> configuration (with user PIRWBUSER) i see "A monitoring configuration for the selected XI domain does not yet exist" and a table with 2 component are checked.
When i try "Save Configuration", it writes " RFCDEST_NOT_CREATED".
and I try to use Runtime Workbench -> end-to-end monitoring.But i get "No process defined for this domain ", when "Display".
Please suggest me,how to procced.
Sridhar:user is aleady having the SAP_XI_MONITORING role.
Regards,
Venkat.

Similar Messages

  • RFC Connection Error (for end-to-end Monitoring)

    Hi,
    I am configure End-to-End monitoring in XI 3.0 SP20, PMI does't show data in end-to-end monitoring... anyway!!! I check RFC connection PMI
    RFC destination name: PMIXQA90020080827
    in TEST connection I am getting an error: "Group PUBLIC not Found" where may I define that PUBLIC to solve this problem please let me know.... thanks
    and what is Group PUBLIC in RFC ??? what does it do???
    Is there any notes I can read for related issue, please help me out this
    Thanks a lot in advanced
    Edited by: issue2008 issue on Aug 28, 2008 10:03 AM

    Thanks for reply... SURE I can tell you
    Connection Type: 3 R/3 connection
    ScreenShot shows blow:
    http://www.flickr.com/photos/25222280@N03/2806290586/sizes/o/
    Thanks
    Edited by: issue2008 issue on Aug 28, 2008 10:20 AM

  • Getting Error while accessing End to end Monitoring.

    Hi,
    We are running XI 3.0 on MS SQL Server. While we hit END to END Monitoring Button we getting some error.
    Here the Error.
    Service cannot be reached
    What has happened?
    URL http://lax05sesd02:50000/sap/bc/bsp/sap/spi_monitor/monitor.do call was terminated because the corresponding service is not available.
    Note
    The termination occurred in system XID with error code 403 and for the reason Forbidden.
    The selected virtual host was 0 .
    What can I do?
    Please select a valid URL.
    If you do not yet have a user ID, contact your system administrator.
    ErrorCode:ICF-NF-http-c:000-u:SAPSYS-l:E-i:LAX05SESD02_XID_00-v:0-s:403-r:Forbidden
    HTTP 403 - Forbidden
    Your SAP Internet Communication Framework Team
    Please help us to solve this issue.

    Hi,
    We are running XI 3.0 on MS SQL Server. While we hit END to END Monitoring Button we getting some error.
    Here the Error.
    Service cannot be reached
    What has happened?
    URL http://lax05sesd02:50000/sap/bc/bsp/sap/spi_monitor/monitor.do call was terminated because the corresponding service is not available.
    Note
    The termination occurred in system XID with error code 403 and for the reason Forbidden.
    The selected virtual host was 0 .
    What can I do?
    Please select a valid URL.
    If you do not yet have a user ID, contact your system administrator.
    ErrorCode:ICF-NF-http-c:000-u:SAPSYS-l:E-i:LAX05SESD02_XID_00-v:0-s:403-r:Forbidden
    HTTP 403 - Forbidden
    Your SAP Internet Communication Framework Team
    Please help us to solve this issue.

  • End-to-end monitoring error!!!!!!

    hi.
    i have a problem.
    i trying to start a new selection in end-to-end monitoring, but i have an error with JNET: java.lang.NullPointerException. can anybody help me to resolve it please??
    another question is: What is JNET?
    is the fist time i configure CCMS and have thousands  problems
    be patiends with me!
    thanks very much!!!

    java.lang.NullPointerException in End-to-End monitoring
    java.lang.NullPointerException in End-to-End monitoring
    Ref. the above threads.

  • Error in Configuration and End to end monitoring

    Hi all,
    I am getting error in RWB  under configuration and end to end  monitoring.
    End to end monitoring iam getting
    "Neither the messager server nor the application server can be reached for system pirdev.titan.co.in"
    and under
    Configuration
    "Cannot read the configuration for the selected domain because the system was unable to connect to the monitoring server (possibly due to incorrect logon data). Error message: Neither the messager server nor the application server can be reached for system pirdev.titan.co.in"
    Please help me.
    Regards
    Pradeep P N

    Hi,
    Have you gone throgh these threads.
    Neither the messager server nor the application server can be reached
    Error when I click "End-to-End monitoring" in XI runtime workbench
    Neither the messager server nor the application server can be reached
    Regards
    Goli Sridhar

  • ** End-to-End Monitoring - RFC destination error while save config in RWB

    Hi Friends,
    We have 2 RFC destinations in our XI server. 1) PMI<client>001 2) PMI<client><client>800. First one is for XI server. Next one is for Sender/Receiver System.
    We want to activate End-to-End Monitoring in RWB. For this, when I save configuration, it throws the following error.
    Incorrect RFC Destinations: When the configuration is saved, an RFC destination is created on the monitoring server for each XI component to enable end-to-end monitoring of the respective XI component. However, the test call failed for the destinations listed. Therefore, you must check the call and the authorization on the monitoring server for the destinations concerned, by using transaction SM59. Also check whether RFC user used for the destination is maintained in the relevant XI component. Note that a component can only be monitored when its RFC destination is maintained correctly.
    I have checked the user in the above destinations. For the first destination, we have assigned PIRWBUSER of XI system. Test Connection is OK, but unable to login remote. At the same time, PIRWBUSER is not locked.
    For the second destination, I have assigned some login user of sender/receiver system. Test connection is OK. Able to login remotely.
    There is no RFC user in our XI system. (I tried using RFCUSER* thru SU01 tcode).
    There is no PIRWBUSER in the Sender/Receiver System.
    In RWB, Configuration, 3 components are there. 1) XIIntegrationServer 2) Business System (for Sender/Receiver System) 3) XI Adapter Framework. I selected last two. (First one is already selected). Monitoring Level : Medium (for all 3). Send and Receive Check box is selcted for the last two.
    So, what could be the problem for the above error?
    Could you kindly clarifiy friends.
    Thanking you
    Kind Regards,
    Jeg P.

    Hi friends,
    I have one RFC Destination PMI<sysid>001. (Abap Connction) in my XI system. This destination is for  XI server. Connection Test is OK. Remote Logon by using the PIRWBUSER is also ok.
    In the 'Configuration' tab of the Runtime Workbench, when we select 'Save Configuration', (Business System and Adapter Framework is not activated) with the default activation for XI Integration Server, the system throws the following error.
    Incorrect RFC Destinations: When the configuration is saved, an RFC destination is created on the monitoring server for each XI component to enable end-to-end monitoring of the respective XI component. However, the test call failed for the destinations listed. Therefore, you must check the call and the authorization on the monitoring server for the destinations concerned, by using transaction SM59. Also check whether RFC user used for the destination is maintained in the relevant XI component. Note that a component can only be monitored when its RFC destination is maintained correctly.
    When we save configuration, an one more destination is automatically created in the name as below.
    PMI<sysid>001<yyyymmdd>. For Example, PMIPID00120080207. 
    When we test  newly created RFC destination, connection is OK, but not able to remot login using the same user PIRWBUSER.
    The difference between old and new RFC destination, in old, we have selected Load Balancing is 'Yes', but in the new it is 'No'. The system also tells the error below.
    Name or Password is incorrect (repeat logon) - PMIPID00120080207
    But, still remote login is possible in the old RFC destination using the PIRWBUSER.
    So, What could be the problem ...?
    Kindly reply, friends.

  • ERWB end to end monitor configuration error

    Error msg:
    Configuration saved RFC ping failed for the following RFC destinations (created upon saving) in the system PI0001: PMIMZ020020090413
    Incorrect RFC Destinations: When the configuration is saved, an RFC destination is created on the monitoring server for each XI component to enable end-to-end monitoring of the respective XI component. However, the test call failed for the destinations listed. Therefore, you must check the call and the authorization on the monitoring server for the destinations concerned, by using transaction SM59. Also check whether RFC user used for the destination is maintained in the relevant XI component. Note that a component can only be monitored when its RFC destination is maintained correctly.
    Incorrect RFC Destinations
    Component Type Name of Component RFC Destination Message for RFC Call
    ALE-LogicalSystem MZ0CLNT200 PMIMZ020020090413 Error when opening an RFC connection
    When  I check the RFC destination, I found XI createPMI destination with Load balancing Status "YES" every time, and failed the connect test.

    Hi,
    Please check the RFC's PMIMZ020020090413 in SM59.
    There you will find the test conncetion tab. Please check if you are able to login to target system or not.
    If not please set the logon parameters and host name.
    Also if the name and password are correct, check the following points
    1. The user is not locked on system that is the target of the RFC.
    2. Assigned the Authorisation object S_RFCACL for the user. It is to allow the user to access the trusted/trusting system.
    3. If you are on PI7.1 please check if the sm59 destination has fully qualified hostname.
    I hope it should solve your problem.
    Best Regards
    Jitender Chauhan.

  • End to End Monitoring is not working

    Hi All,
    I don't see the msgs in End to End Monitoring. I have checked all connections in SM59, full host name parameters is present in profile.
    I cannot select the "instance" radio button either. Anyone had these problems in SP12, XI3.0 SR1.
    thanks
    tony

    Hi All,
    I have also same problem of end to end monitoring ,it does not refreshing statistics after certain interval,
    currently statitical data is showing like
    Errors 0
    Open 0
    Successfully Completed 0
    Overall 0
    I have set frequency of hourly  in furthur settings.
    But messages are not seen , it is showing only starting (when we configured end to end monitoring) days message statistics .
    Expecting some clue to resolve this.
    Thanks in advance
    Regards,
    Santosh

  • GUID FormatExceptionError in End to End Scenario at runtime, but no error in Message Mapping test

    Hi Friends
    My scenario is Idoc to RFC and , my mapping is working fine and executing successfully in the message map tab but , it is failing in the End to End case at runtime with GUIDFormatException error, can anyone please help on this , I have searched the forum and no proper or concrete answers are available , creating a separate or new channel is not an option.

    Hi,
    Check in which step you are receiving this error
    1st check in SXMB_MONI/trace
    2nd If the above is successful then check in rwb/comm channel monitoring/receiver rfc channel.
    Regards
    Venkat

  • End to End Monitoring

    Hello,
    I have implemented this scenario :
    "Flat file ->mapping->BPM (for calling a bapi)->mapping->Flat file" and when i use the message monitoring sometimes end-to-end monitoring is available and sometimes not, Why ??? Is there a specific configuration for enable end-to-end monitoring in any case ?
    Regards
    Vincent

    Hi,
    What error do you get ? I consistently get this error :-
    Service cannot be reached
    What has happened?
    URL http://axonlabs11.axonlabs.co.uk:8000/sap/bc/bsp/sap/spi_monitor/monitor.do call was terminated because the corresponding service is not available.
    Note
    The termination occurred in system XI3 with error code 403 and for the reason Forbidden.
    The selected virtual host was 0 .
    What can I do?
    Please select a valid URL.
    If you do not yet have a user ID, contact your system administrator.
    ErrorCode:ICF-NF-http-c:000-u:SAPSYS-l:E-i:axonlabs11_XI3_00-v:0-s:403-r:Forbidden
    HTTP 403 - Forbidden
    Your SAP Internet Communication Framework Team
    Kind regards
    Colin.

  • Error in End to End Monitering:  java.lang.NullPointerException

    Hi Experts,
                   while tryimg to configure the end to end monitering in my system, when i open the RW- > end to end monitering , I get teh following error.
      java.lang.NullPointerException
    I hav already added the PMI Monitering parameter in the SXMB_ADM -> integration engine configuration.
    Any feed experts!
    Regards,
    Arnab .

    Hi Arnab,
    Go Throgh the following thread.
    Re: java.lang.NullPointerException in End-to-End monitoring
    Regards
    Goli Sridhar

  • Jnet exception in RWB in end-to-end-monitoring

    hi,
    i have problems with jnet in end-to-end-monitoring:
    java.lang.NullPointerException
         at com.sap.plaf.frog.FrogScrollPaneUI$1.propertyChange(FrogScrollPaneUI.java:113)
         at java.beans.PropertyChangeSupport.firePropertyChange(Unknown Source)
         at java.beans.PropertyChangeSupport.firePropertyChange(Unknown Source)
         at java.awt.Component.firePropertyChange(Unknown Source)
         at javax.swing.JScrollPane.setHorizontalScrollBar(Unknown Source)
         at javax.swing.plaf.basic.BasicComboPopup.createScroller(Unknown Source)
         at javax.swing.plaf.basic.BasicComboPopup.<init>(Unknown Source)
         at com.sap.plaf.frog.FrogComboPopup.<init>(FrogComboPopup.java:21)
         at com.sap.plaf.frog.FrogComboBoxUI.createPopup(FrogComboBoxUI.java:410)
         at com.sap.plaf.frog.FrogComboBoxUI.installUI(FrogComboBoxUI.java:178)
         at javax.swing.JComponent.setUI(Unknown Source)
         at javax.swing.JComboBox.setUI(Unknown Source)
         at javax.swing.JComboBox.updateUI(Unknown Source)
         at javax.swing.JComboBox.init(Unknown Source)
         at javax.swing.JComboBox.<init>(Unknown Source)
         at com.sap.jnet.clib.JNcToolBar$ComboBox.<init>(JNcToolBar.java:68)
         at com.sap.jnet.clib.JNcToolBar.addComboBox(JNcToolBar.java:196)
         at com.sap.jnet.clib.JNcAppWindow.newUI(JNcAppWindow.java:878)
         at com.sap.jnet.clib.JNcAppWindow.newData(JNcAppWindow.java:1520)
         at com.sap.jnet.JNetData.createGraphFromDOM(JNetData.java:594)
         at com.sap.jnet.JNetData.load(JNetData.java:815)
         at com.sap.jnet.JNetApplet.initJNetApplet(JNetApplet.java:508)
         at com.sap.jnet.JNetApplet.access$000(JNetApplet.java:40)
         at com.sap.jnet.JNetApplet$1.run(JNetApplet.java:283)
         at java.awt.event.InvocationEvent.dispatch(Unknown Source)
         at java.awt.EventQueue.dispatchEvent(Unknown Source)
         at java.awt.EventDispatchThread.pumpOneEventForFilters(Unknown Source)
         at java.awt.EventDispatchThread.pumpEventsForFilter(Unknown Source)
         at java.awt.EventDispatchThread.pumpEventsForHierarchy(Unknown Source)
         at java.awt.EventDispatchThread.pumpEvents(Unknown Source)
         at java.awt.EventDispatchThread.pumpEvents(Unknown Source)
         at java.awt.EventDispatchThread.run(Unknown Source)
    my jre is 1.6.0_11
    thanks christoph

    hi,
    now, i have anothe problem. i am in end-to-end-monitoring ans start the selection from the past. on right site - i see the jnet flowchart. in the final error box i do a doubleclick and a attribute display popup is coming. when i am calling the application: message id i become a popup window with an error message 'ashost' is missing. in exchangeprofile under Runtime Workbench the parameter: com.sap.aii.rwb.server.centralmonitoring.r3.ashost is set to normally hostname not fqdn.
    do you have an idea?
    christoph

  • PMI Problem (End-to-End Monitor does not show data)

    (End-to-End Monitor does not show data)
    As I know that XML Messages Alerts T-code: SXMB_NOMI shows all alerts including errors as well I put date Range: 01-01-2008 to 01-08-2008 and filters for "Errors" system does show more then 300 errors
    But problem in RWB - End-to-End Monitoring, when I click on display and date range 01-01-2008 to 01-08-2008 its give me graphical overview in right of window
    and shows summary:
    Errors:                     0  Average
    Open                  904  Maximum
    Successfully Completed         0  Minimum
    Overall:                  904
    I thing End-to-End Monitor doesn't get data from PMI...
    why does't show any errors, which is shows in SXMB_MONI
    Please tell me how to resolve that problem
    Thanks in Advanced
    Edited by: issue2008 issue on Aug 26, 2008 12:02 PM

    Hi,
    A destination pointing to the Integration Server is created on the J2EE engine to collect the data for the end-to-end monitoring. If this destination is incorrect or if there are several clients in the system of the integration server, the data may be sent to the incorrect client.
    This might be a reason so you can  implement the correction of the destination in a manual way as follows:
    Open the J2EE visual administrator.
    Select the Destination service.
    Select the HTTP "pmistore" destination.
    Enter the URL for the ICF service spi_gate of the Integration Server in the following form "http://<host>:<port>/sap/bc/spi_gate?sap-client=<xxx>", where 'host' denotes the host of the integration server, 'port' denotes the HTTP port, and xxx is the client of the Integration Server.
    Thanks,
    Hemant

  • Problem in XI 30 with End-to-End Monitoring

    Hi people,
    I'm acceding to the End-to-End Monitoring in the Runtime Workbench.
    After I introduce all the data for monitoring messages and click
    Display.
    It shows the error:
    [code]java.lang.NullPointerException
         at com.sap.plaf.frog.FrogScrollPaneUI$1.propertyChange(FrogScrollPaneUI.java:113)
         at java.beans.PropertyChangeSupport.firePropertyChange(Unknown Source)
         at java.beans.PropertyChangeSupport.firePropertyChange(Unknown Source)
         at java.awt.Component.firePropertyChange(Unknown Source)
         at javax.swing.JScrollPane.setHorizontalScrollBar(Unknown Source)
         at javax.swing.plaf.basic.BasicComboPopup.createScroller(Unknown Source)
         at javax.swing.plaf.basic.BasicComboPopup.<init>(Unknown Source)
         at com.sap.plaf.frog.FrogComboPopup.<init>(FrogComboPopup.java:21)
         at com.sap.plaf.frog.FrogComboBoxUI.createPopup(FrogComboBoxUI.java:410)
         at com.sap.plaf.frog.FrogComboBoxUI.installUI(FrogComboBoxUI.java:178)
         at javax.swing.JComponent.setUI(Unknown Source)
         at javax.swing.JComboBox.setUI(Unknown Source)
         at javax.swing.JComboBox.updateUI(Unknown Source)
         at javax.swing.JComboBox.init(Unknown Source)
         at javax.swing.JComboBox.<init>(Unknown Source)
         at com.sap.jnet.clib.JNcToolBar$ComboBox.<init>(JNcToolBar.java:64)
         at com.sap.jnet.clib.JNcToolBar.addComboBox(JNcToolBar.java:192)
         at com.sap.jnet.clib.JNcAppWindow.newUI(JNcAppWindow.java:538)
         at com.sap.jnet.clib.JNcAppWindow.newData(JNcAppWindow.java:966)
         at com.sap.jnet.JNetData.createGraphFromDOM(JNetData.java:488)
         at com.sap.jnet.JNetData.load(JNetData.java:674)
         at com.sap.jnet.JNetData.load(JNetData.java:710)
         at com.sap.jnet.JNetApplet.init(JNetApplet.java:545)
         at sun.applet.AppletPanel.run(Unknown Source)
         at java.lang.Thread.run(Unknown Source)
    [/code]
    The version of my JVM is: build 1.5.0_08, but also I have test in
    another computer with version 1.4.2_12 of the JVM. Additionally, the
    version of JAVA Web Start is 1.0.1_02.
    What could be happening?
    Is a problem with my clients??? Is a problem with .jar????
    Kind regards,

    Himadri,
    In the exchange profile the port and host name are correct.
    Venkat,
    Yes, it shows the log-in pop up and I have access to the next window (it's divided in two parts, to the left I select the values; and to the right with the client java). But before acceding this window, it shows the error that I comment and the right part shows "JNET Aborted...".
    If I press “Start Selection”, the java client try to load and shows the same error.

  • RWB-Message Monitoring and End-to-End Monitoring

    hi
    Can someone explain the differences between Message Monitoring & End-to-End Monitoring through RWB. I see both of them displaying the messages status with better descriptive with End-to-End Monitoring.

    HI Chandra
    You use message monitoring in the following cases:
    1 To track the status of messages
    2 To find errors that have occurred and establish what caused them
    Check this help for further info:
    http://help.sap.com/saphelp_nw04/helpdata/en/2f/4e313f8815d036e10000000a114084/content.htm
    You use end-to-end monitoring in the following cases:
    1 If you want to monitor message processing steps in a number of SAP components (to be configured).
    2 If you want to monitor the path of individual messages through these SAP components, from start to end.
    Check this help for further info:
    http://help.sap.com/saphelp_nw04/helpdata/en/82/9e8dfe9eadbd4b9194c433e646b84e/content.htm
    End-to-end monitoring includes message monitoring, adapter monitoring, BPE if BPM is involved.. so end-to-end monitoring tells you complete description of your scenario......but message monitoring is concerned only with source message coming to target message successfully generated.
    Cheers..
    Vasu
    <i>** Reward Points if found useful **</i>

Maybe you are looking for

  • Editable Text

    I need to create PDFs with text content editable by others.  The text needs to conform to styling created in the Photoshop document. For example, other users need to be able to change the heading on a page, but retain font color and size.  How to I e

  • Files appear to be missing from my hard drive - FCP 5.1.4

    I am having an issue with my external hard drive(has both USB and FIREWIRE). I had downloaded P2 files to my hard drive, checked and double checked to make sure they were there(using FCP). Then I ejected the hard drive to reconnect it using Firewire

  • Issue with WRT120N Firmware in NZ

    Hi guys. I'm residing in New Zealand and I've had the Wireless-N Home Router WRT120N for a year or so, I recently had trouble accessing the router and I am not able to reset the **bleep** thing to factory default settings so I can re-setup. I read t

  • Acrobat Pro X reinstall Fails

    I received an Acrobat Pro update notification and started the update process. Update failed and the message said it needed to uninstall and reinstall Acrobat Pro. I followed Adobe’s advice. But I have not been able to get Acrobat Pro to finish instal

  • Sales order right click option

    Hai,   Is it possible to deactivate the right click option in the sales order document. Regards, Gokul K.