Error type 102

I have an i book a friend gave me but when i put it on it says error type 102 temporary turn off extensions ,restart and hold down the shift key but is not doing nothing after i hold the key and shut it down .not even the cursor comes up . Is somebody else having the same problem ?

Usually when a vintage computer running Mac OS 9 shows that message
that could mean the version of OS 9.2 was arrived at incorrectly and may
not be for the computer it was installed on. A base level OS 9, updated,
only goes so far; a retail install disc for a later version is required; plus
any original update files. Most older support site links no longer work, so
if you see some information online pointing to Apple Support - Mac OS 9,
they generally put you on the newer home page, nothing about OS9/8/7.
If you have a compatible Mac OS system on DVD or CD for the computer,
depending on what vintage it is, you could attempt to use the Disk Tools
on there to check the hard disk drive, repair it, and perhaps erase & install
a new system.
You don't really say much about the computer, the situation involves details
and most of them are lacking where they are necessary to attempt to help.
The details vary according to the exact build model series iBook G3/G4
you have. Some last model ones do not boot into OS9 at all, but can use
OS9 as Classic in an OS X computer, no later than Tiger 10.4.11.
If your computer originally ran OS 8.1 through 8.6, a Mac OS 9.0 or later
retail install disc may work. If it supports OS 9.2, if you want to end up at
OS 9.2.1 or OS 9.2.2, get a retail OS 9.2.1 Install CD.
Is this a clamshell colors early G3 iBook, if so which one? If it is a white G3
iBook, (first was 500MHz dual-usb) which one? Then, they went to G4 as a
processor base. These also have different system/hardware requirements.
And they shipped with compatible discs, with part numbers for their series.
The error message implies the incorrect OS version was installed or partial
installation had failed; there may also be other hardware issues involved.
An old obsolete KB article from Apple support suggests the system is too
old for the computer to use; but it may be an improper installation of one
that is not correct for the ROM version of the computer. Perhaps you have
an older computer that was supposed to have a firmware update, too?
Does the iBook have a tray-load optical drive, or a slot-load? Here's a page
of iBook models, all models from the first to last; to help identify your model.
There also is a page where you can figure exactly what one you have.
•Apple iBook Specs (All iBook Technical Spec) - everymac:
http://www.everymac.com/systems/apple/ibook/index-ibook.html
The issue likely is the lack of matching supported software, to include correct
installer discs and other items; some models required firmware update to run
a later system. Mostly after OS X was introduced a major update was issued.
Good luck!

Similar Messages

  • Error Type 102 in 9.2.2

    All of a sudden I'm getting a system bomb with an error type 102. The hard drive boots well into 10.3.3. I've run norton disk doctor and everything checks out. I get a disk icon with a questions mark and then the 9.2 logo comes up with a system bomb and the error type 102 message. The same thing happens when I try to boot without extensions. HELP!!

    Dennis, you didn't fully read the DiskWarrior page. Here's what it says:
    "DiskWarrior ships on a CD-ROM that will start up in Mac OS X on a Mac with a G3 or higher processor (including a G5) with built-in USB and 128 MB (256 MB recommended) of RAM.
    Once started from the DiskWarrior CD, DiskWarrior can be run from the CD to eliminate all damage to any HFS (Mac OS Standard) and HFS Plus (Mac OS Extended) disk directories, including your normal startup disk as well as journaled disks (but not case-sensitive disks). Version 2.1 of DiskWarrior, also included, runs and installs on a 68020 Mac or better when started from Mac OS 7.1 to 9.x. Either version of DiskWarrior repairs any supported disk no matter which version of the Mac OS is installed on the disk being repaired."
    So, it will work for you.
    Is your OS 9.2.2 on a separate partition? Or on the same volume/partition as OS X with OS 9 running as Classic?
    Cheers, Tom

  • Error Type 102, Unimplemented Trap, Will not initialize...

    Among a lot of eight iMacs that were donated to us, there are a pair of them each with their own issues. Both are old CRT iMacs from 2001 with 266MB of RAM.
    (#1)
    This iMac initially was advertising an "Unimplemented Trap." I could boot up with the shift key or the C key down, but not otherwise.
    By the recommendation of a number of websites, I tried altering the extension expression with the extension manager. Even if I unchecked every box in the extension manager, the reboot would not be successful, requiring either shift or C to be pushed to get past the "OS 9.2" boot screen.
    With the computer not responding to the alterations in the extension manager, I put in the OS 9.2.1 disc and ran a complete install. During installation, it warned me that the Remote Access 4.0 required Open Transport 2.0 (or something to this effect).
    After the install, I am now getting an "Error Type 102" at start up. I can still restart with the shift or C key, but I remain unable to have any positive effect on booting even after unchecking every conceivable box within the extension manager.
    Any suggestions?
    (#2)
    This iMac boots successfully in the sense that it gets beyond the start up screen to the Desktop. Once it gets there, mouse inputs are received with respect to movement, but neither key strokes nor mouse clicks have any effect.
    When a CD is not in the drive, it will load a window labeled "Launcher" with nothing inside at the moment the computer stops initializing.
    When a CD is in the drive, it will load a window displaying all of the CD's contents at the moment the computer stops initializing.
    When I boot with shift, the Extension Manager can not be opened, "because it is locked."
    When I try to boot with C, I get an icon of a disk with a flashing question mark at the initial gray screen.
    Problem with the CD drive? Any ideas?
    Thanks a million. Getting these computers working would be a huge help: we need them to be working when school starts in two weeks and we don't have the money to purchase new computers.

    To Apple Discussions!
    *Unimplemented Trap Error*
    Probable Causes: There are several.
    Can involve the Macintosh's ROM (read only memory), where core operating system routines are stored. The error can occur when a request made for a routine that's in ROM could not be completed because the routine was unavailable. Typically, this error is caused by older software that assumes an older version of ROM. The software in question could be an application or a system extension.
    Unimplemented Trap error can also occur when the Macintosh model or the system software is too old for your application(s). While most software is written to be backward compatible (i.e., designed to work with older hardware models and system versions), it is not possible to be compatible with every Macintosh and system software version.
    Possible Solutions:
    Make sure your software is current and is compatible with your Macintosh model and system software.
    Most software applications include system requirements in the documentation or on the outside of the box. If your configuration does not meet the minimum requirements, upgrade your configuration as necessary.
    Similarly, if you are using an application that is more than one major version older than the current version (major versions being 2.0, 3.0, 4.0 and minor versions being 2.01, 2.2, 2.2.3, etc.), but your Macintosh model and system software are current, upgrade your application to the current version.
    ============
    According to Article: http://support.apple.com/kb/HT2088 Mac OS System Error Codes: 1 to 32767
    Error Type 102 = System is too old for this ROM
    =============
    http://docs.info.apple.com/article.html?artnum=58042 Macintosh: Flashing Question Mark at Startup
    ============
    "Among a lot of eight iMacs that were donated to us,"
    Hopefully, you were also given the System CDs that originally came w/those iMacs. If not, you can get replacement System Install & Restore CDs from Apple's Customer Support - in the US, (800) 767-2775 - for a nominal S&H fee. You'll need to have the model and/or serial number of your Mac available.

  • "system error type 102"?

    OK, I recently had to remove the drive in my PowerMac G3 that had OS X Panther on it and now am using my drive with OS 9.2.2. But when it starts up, it says it cant because of the a type 102 error, and it tells me to restart using no extensions using the shift key. It starts up fine when I do, but how do I fix it from there? I'm planning on reinstalling Panther today so help would be appreciated.

    Despite Tom's otherwise excellent advice, I find holding down the spacebar at startup often makes my Mac unstable. Often, it will not proceed to boot after extensions are re-arranged.
    I prefer to boot up (using the shift key the first time to get extensions off) then use Extensions Manager in the running system (not at boot-up) to add a few extensions at a time and re-boot. Using a different name for each incremental set allows you to return to a previously-working set after a bad choice, and continue the investigation.

  • 'Goods movement not possible with mvmt type 102'

    Dear Experts,
    I have to reverse the GR and I am using BAPI -> BAPI_GOODSMVT_CREATE and passing below information but I am getting error message as 'Goods movement not possible with mvmt type 102'. Could any one please tell me what would be the possible reasons to get this error and how can I fix this.
    goodsmvt_header-PSTNG_DATE = 20110705
    goodsmvt_header-DOC_DATE = 20110705
    goodsmvt_code-GM_CODE = 06
    goodsmvt_item-PLANT = 1400
    goodsmvt_item-MOVE_TYPE = 102 <<< Reversal movement type
    goodsmvt_item-ENTRY_QNT = 02
    goodsmvt_item-ENTRY_UOM = SET
    goodsmvt_item-PO_NUMBER = W299999508
    goodsmvt_item-PO_ITEM = 0010
    goodsmvt_item-MVT_IND = B
    goodsmvt_item-XSTOB = ''. << space to use reversal types
    Thanks in Advance
    Venkat

    Hi Please provide Material Document, Document Year and Posting date as shown below
    MATDOCUMENTYEAR = DOC_YEAR.
    GOODSMVT_PSTNG_DATE = POSTING_DATE.
    MATERIALDOCUMENT = MAT_DOC
    CALL FUNCTION 'BAPI_GOODSMVT_CANCEL'
        EXPORTING
          MATERIALDOCUMENT          = MATERIALDOCUMENT
          MATDOCUMENTYEAR           = MATDOCUMENTYEAR
          GOODSMVT_PSTNG_DATE       = GOODSMVT_PSTNG_DATE
        GOODSMVT_PR_UNAME         =
       IMPORTING
         GOODSMVT_HEADRET          = WA_GOODSMVT_HEADRET
        TABLES
          RETURN                    = IT_RETURN
        GOODSMVT_MATDOCITEM       =
      CALL FUNCTION 'BAPI_TRANSACTION_COMMIT'
        EXPORTING
          WAIT = 'X'.

  • Error while executing "" command Error type ACCESS VIOLATION Error Address: 0006898E Module name:gfsdesk.DLL

    Hi All,
    I'm using diadem from .net Program. While on the run I'm getting the following error.
    Error While executing "" Command
    Error type ACCESS VIOLATION
    Error Address: 0006898E
    Module name:gfsdesk.DLL
    Anyone have any idea why this is happening?
    regards,
    Swaroop

    Hi Swaroop,
    It would be helpful to better understand what your code really does. The information that you called DIAdem from your enviroenment is not yet sufficient to understand what the problem might be.
    Andreas

  • Error:Type conflict when calling a function module RFC_ERROR_SYSTEM_Failure

    Hi Experts,
    When I run my Application in Portal, i am getting the following error.
    Type conflict when calling a function module., error key: RFC_ERROR_SYSTEM_FAILURE
    When I execute the BAPI, it is getting executed.
    My Bapi Strucute:
    Import Parameters
    IM_MAT_Search --> ZPTIP_MAT --> Import Parameters
    Tables
    IT_INFO_REC --> ZMM_GET_ITEM --> Output Parameters
    When I import the model, i am getting the structure like this
    BAPI_Name > ZMM_BAPI_Input> IM_MAT_Search(respective Parameters) , Output (respective Tables and their parameters)
                        > ZMM_Input1> Parameters
    This is the way, how i am executing in webdynpro java
    Zmm_Bapi_Ptip_Search_Input eleInput = new Zmm_Bapi_Ptip_Search_Input();
    wdContext.nodeZmm_Bapi_Ptip_Search_Input().bind(eleInput);
    Zptip_Asset eleInputAsset = new Zptip_Asset();
    eleInputAsset.setSearch("ACRS");
    wdContext.nodeZptip_Asset().bind(eleInputAsset);
    eleInput.setIm_Ast_Search(eleInputAsset);
    wdContext.nodeZmm_Bapi_Ptip_Search_Input().bind(eleInput);
    wdContext.nodeZmm_Bapi_Ptip_Search_Input().currentZmm_Bapi_Ptip_Search_InputElement().modelObject().execute();
    wdContext.nodeOutput().invalidate();
    Please let me know, how to do the same.
    Thanks in advance.
    Regards,
    Palani

    Hi David,
    I checked for the Parameter of setIm_Ast_Search, it is of Zptip_Asset.
    Hi Saleem,
    When I changed the same, i am getting the Type conflict error,
    Type conflict when calling a function module., error key: RFC_ERROR_SYSTEM_FAILURE
    Please let me know,what can be done in this regard to solve the problem.
    My BAPI Structure when imported as model
    SearchBAPI
    --> ZMM_BAPI_SEARCH_INPUT
    > IM_AST_SEARCH(zPTIP_ASSET)
    >Zptip_Asset
    >Search (Parameter)
    > OutPut(ZMM_BAPI_Search_Output)
    >IT_Asser_Rec(ZMM_Asset)
    >ZMM_Asset
    >TXT100 (output Parameter)
    --> ZMM_BAPI_SEARACH_OUTPUT
    --> ZPTIP_ASSET
    >Search (Parameter)
    Thanks & Regards,
    Palani
    Edited by: Palani Appan on Nov 11, 2009 5:31 PM

  • What is d BAPI for reversal of Good Receipt Note(GRN) for movement type 102

    Hi ABAPers,
       I have got requirement like this , I have done Goods Receipt Note (GRN) based on Purchse order Number using '.BAPI_GOODSMVT_CREATE' with 101 movement type.
       But now my requirement is reversal of good receipt note(GRN) based on Material Document Number (or) Purchase Order Number with 102 movement type. what is the bapi name i need to use. and i need to give reason for the reversal of GRN.
    please tell me the field name for reason  in bapi.
    i have searched in the net, but i could not get proper answer to this isse.
    Highly appriciate who gives answer as early as possible. I need to complete this task EOD. please give replies.
    Thanks & Regards,
    Vinay Kumar.

    Hi,
    If your material document has specific movement type i.e. 101, if you cancel document using BAPI_GOODSMVT_CANCEL, it automatically picks associated movement type 102 defined in customizing setting, you don't need to pass 102 explicitly while cancelling.
    I have not seen reason code in this bapi, but it is required to pass reason code then you may try transaction code MBST using BDC.
    Thanks,
    Ashok Veer

  • Creative Cloud Installation Failed Download Error - Error Type -7 and Error Code - 401

    I subscribed to Creative Cloud in December 2012 and have been trying to install the applications, but the "Installation Failed" through the Adobe Application Manager. (see screenshot)
    Here is a line from my log file:
    01/08/13 11:08:48:346 | [WARN] |  | ASU | PDApp | DownloadError |  |  | 6120 | Download Error has come with GDE Error type - -7 and error code - 401
    I tried searching for the same error code in the "knowledge base" but couldn't locate any.
    I am on a Windows 7 (x64) machine. I also have CS5.5 installed.
    Anyone have this problem? Please help or point me in the right direction if you can. Thanks!

    Thanks Romsinha,
       I tried the above steps, with no luck.  I have admin rights on both laptop and desktop I'm trying to install to.  I have updated my AAM on both machines with no issue (when using the direct link above). But when I click the 'Try' link to download an application, it shows the scrolling status bar for a few seconds, then  "Installation Failed"  'Download error. Press Retry to try again or contact customer support. (-7)'   Retry only produces same results.
    Both machines are running Win 7 Pro - SP1 64bit
         (laptop - 16 GB RAM & Core i7-2760QM 2.40 GHz processor)
         (desktop - 8 GB RAM & Xeon W3520 2.67GHz processor)
    I am running in a corporate setting with I'm sure all sorts of Firewall protection etc...
    I'm planning on asking for a CC membership, but wanted to check out the new features first....
    Thanks!

  • IPhone 6 Plus 16GB blue screen crashes: Read, error type:Address map hole or size mis-match

    Hi folks,
    Some time ago I had a 16GB 6+ and it crashed with the blue screen, so I returned it. I now have a brand new one that I got from Tmobile ($75 return fee) and although it has mostly worked just fine, I have gotten 2 blue screen crashes. Below are the details from the phone's log.
    What strikes me is the message "Read, error type:Address map hole or size mis-match".
    Does anyone know if this could be caused by a hardware defect?
    I've gotten one of these crashes running iOS 8.1.2 and another in 8.1.3.
    Thanks.
    Incident Identifier: 20304759-E90B-453F-BDC5-176AF4E30041
    CrashReporter Key:   fcf18d230005749957728546dea3221a0c588330
    Hardware Model:      iPhone7,1
    Date/Time:           2015-01-25 19:43:44.913 -0800
    OS Version:          iOS 8.1.2 (12B440)
    panic(cpu 0 caller 0xffffff8008cd45d0): L2C PIO error (src:core0-AF snoop, address:0x1202030208, access:Read, error type:Address map hole or size mis-match, L2C_ERR_STS:100003fc00000202, L2C_ERR_ADR:0x1108e1202030208, L2C_ERR_INF:0x2107)
    Debugger message: panic
    OS version: 12B440
    Kernel version: Darwin Kernel Version 14.0.0: Mon Nov  3 22:27:30 PST 2014; root:xnu-2783.3.22~1/RELEASE_ARM64_T7000
    iBoot version: iBoot-2261.3.33
    secure boot?: YES
    Paniclog version: 3
    Kernel slide:     0x0000000006000000
    Kernel text base: 0xffffff8008002000
    Epoch Time:        sec       usec
      Boot    : 0x54bc22ef 0x00000000
      Sleep   : 0x54c58398 0x0002abb4
      Wake    : 0x54c583ae 0x000f08df
      Calendar: 0x54c5b7e3 0x00025045

    same with my iPhone 4s 16gb
    {"os_version":"iOS 8.1.3 (12B466)","bug_type":"110"}
    Incident Identifier: 582496DB-6999-468C-9504-3D1C191B9F4B
    CrashReporter Key: 623a577555e51ed110b937358adfa66fba3ea447
    Hardware Model: iPhone4,1
    Date/Time: 2015-02-20 04:17:50.830 +0300
    OS Version: iOS 8.1.3 (12B466)
    panic(cpu 0 caller 0x83dc8347): "i2c1::_checkBusStatus Bus is still in a bad state; last write status 00010110 xfer 00000000 fifo 00000000 for device als"
    Debugger message: panic
    OS version: 12B466
    Kernel version: Darwin Kernel Version 14.0.0: Mon Jan 12 21:30:11 PST 2015; root:xnu-2783.3.26~3/RELEASE_ARM_S5L8940X
    Kernel slide: 0x0000000003400000
    Kernel text base: 0x83401000
    Boot : 0x54e68884 0x00000000
    Sleep : 0x54e68a7e 0x000dd6ac
    Wake : 0x54e68b19 0x00035c02
    Calendar: 0x54e68b1d 0x00040927
    Panicked task 0x84a87c60: 13773 pages, 122 threads: pid 0: kernel_task
    panicked thread: 0xc5066e80, backtrace: 0x81a33ca0
    0x834ad94d
    0x834adcb1
    0x8341d5bd
    0x83dc8347
    0x83dc8059
    0x83dc7e35
    0x8389c601
    0x8389c513
    0x836f6f65
    0x8389cc6d
    0x8389ccc5
    0x83a9f18d
    0x83a9c27f
    0x83a9c73f
    0x83a9c90d
    0x836f6f65
    0x83a9c8e5
    0x836e91e7
    0x8343ed9b
    0x834ab59c
    Task 0x84a87c60: 13773 pages, 122 threads: pid 0: kernel_task
    Task 0x84a87948: 771 pages, 3 threads: pid 1: launchd
    Task 0x84a87000: 2016 pages, 13 threads: pid 17: UserEventAgent
    Task 0x84a87630: 481 pages, 4 threads: pid 18: misd
    Task 0x84a87318: 4114 pages, 22 threads: pid 19: CommCenter
    Task 0x87a62948: 349 pages, 2 threads: pid 21: keybagd
    Task 0x87a62318: 574 pages, 4 threads: pid 23: iaptransportd
    Task 0x87a62000: 868 pages, 9 threads: pid 24: configd
    Task 0x87a7ac60: 793 pages, 4 threads: pid 25: lockdownd
    Task 0x87a7a948: 1218 pages, 6 threads: pid 26: imagent
    Task 0x87a7a630: 2771 pages, 4 threads: pid 27: atc
    Task 0x87a7a318: 792 pages, 2 threads: pid 28: fairplayd.H1
    Task 0x87a7a000: 1571 pages, 14 threads: pid 29: aggregated
    Task 0x87c4ac60: 1069 pages, 4 threads: pid 30: routined
    Task 0x87c4a318: 707 pages, 5 threads: pid 33: timed
    Task 0x87d23c60: 646 pages, 2 threads: pid 35: installd
    Task 0x87d23948: 2383 pages, 11 threads: pid 36: mediaserverd
    Task 0x87d23318: 1279 pages, 11 threads: pid 38: ubd
    Task 0x87d23000: 249 pages, 7 threads: pid 39: syslogd
    Task 0x87d6ac60: 410 pages, 2 threads: pid 40: softwareupdated
    Task 0x87d6a948: 851 pages, 5 threads: pid 41: mediaremoted
    Task 0x87d6a630: 1877 pages, 7 threads: pid 42: identityservices
    Task 0x87d6a318: 9938 pages, 16 threads: pid 43: SpringBoard
    Task 0x87d6a000: 453 pages, 2 threads: pid 44: fileproviderd
    Task 0x87e25c60: 609 pages, 4 threads: p

  • Send Error Type or Description of failed messgaes in body of mail using SMTP adapter

    Hi,
    I want to send failed messages error type or description to admin to notify him for error occurs in BizTalk, with Error description in body part.
    I have set Send port option for "Enable routing of failed messages" and created a send port having SMTP adapter. Now in body I want to send error description.
    Pls advise how can I achieve this.
    -- Kind Regards Sandeep

    When failed message routing is enabled, BizTalk Server does not suspend the message—it routes the message instead.
    When a failed message is generated, BizTalk Server promotes error-report-related message context properties and demotes regular message context properties before publishing the failed message. Compare this to the default behavior when
    failed message routing is not enabled: Messages that fail are suspended. --------
    MSDN
    So if i were in this situation i would prefer to route the failed message to SMTP as well as to some kind of transport from which i can again receive the message ( like MSMQ or File).
    I mean create a send port group and bind 2 send port to this group (SMTP and MSMQ) and bind this group to that orchestration (specified in previous post) which subscribe the Failed Messages. Then bind the MSMQ location to your receive
    location to retry.
    I am not sure wheather it is the optimal solution or not ..... but it will work. Kindly let me know if you are not clear with what i said.
    Regards 

  • HTTPIO_PG_MI_ERROR with error code 102:CLIENT_SEND_FAILED

    Hi Experts ,
    I  was getting HTTPIO_PG_MI_ERROR with the  error test showing Error WHILE SENDING BY HTTP with Error code showing like 102 in the R/3 system , and  the interface is synchronous mode.
    Please help me ..
    Thnks in Advance.

    Hi,
    i am sory small correction in the  the error it is 
       with error code 102:CLIENT_SEND_FAILED with the test HTTPIO_PLG_MPI_ERROR
    thnks so much

  • Help I cant update the 2014 security. I keep getting error code 102

    My computor has updates that I cant get to update. itunes 11.2.2 and security update 2014-002 1.0. I have tryed many times but I keep getting error code 102. does anyone know what is happening?

    kbprovo,
    Try updating using the stand alone installer.
    Go to Safari/Preferences, General tab, for Save downloaded files to: select other then select desktop from the left side bar. This will download the stand alone installer to your desktop. Then double click on it and follow the prompts.
    You have not disclosed your version of OSX so I will include multiple versions.
    Mavericks security:
    http://support.apple.com/kb/DL1740
    Mountain Lion
    http://support.apple.com/kb/DL1738
    Lion
    http://support.apple.com/kb/DL1738
    Try using an ethernet connection if possible, less chance of corruption.
    You can also try this in safe mode
    power off, power on holding the shift key till you see the progress bar then release and allow to finish booting, then try.
    Itunes
    http://support.apple.com/kb/DL1614

  • Bulk load data conversion error (type mismatch or invalid character for the specified codepage) for row 1, column 3 (NumberOfMultipleMatches).

    Hi,
    I have a file where fields are wrapped with ".
    =========== file sample
    "asdsa","asdsadasdas","1123"
    "asdsa","asdsadasdas","1123"
    "asdsa","asdsadasdas","1123"
    "asdsa","asdsadasdas","1123"
    ==========
    I am having a .net method to remove the wrap characters and write out a file without wrap characters.
    ======================
    asdsa,asdsadasdas,1123
    asdsa,asdsadasdas,1123
    asdsa,asdsadasdas,1123
    asdsa,asdsadasdas,1123
    ======================
    the .net code is here.
    ========================================
    public static string RemoveCharacter(string sFileName, char cRemoveChar)
                object objLock = new object();
                //VirtualStream objInputStream = null;
                //VirtualStream objOutStream = null;
                FileStream objInputFile = null, objOutFile = null;
                lock(objLock)
                    try
                        objInputFile = new FileStream(sFileName, FileMode.Open);
                        //objInputStream = new VirtualStream(objInputFile);
                        objOutFile = new FileStream(sFileName.Substring(0, sFileName.LastIndexOf('\\')) + "\\" + Guid.NewGuid().ToString(), FileMode.Create);
                        //objOutStream = new VirtualStream(objOutFile);
                        int nByteRead;
                        while ((nByteRead = objInputFile.ReadByte()) != -1)
                            if (nByteRead != (int)cRemoveChar)
                                objOutFile.WriteByte((byte)nByteRead);
                    finally
                        objInputFile.Close();
                        objOutFile.Close();
                    return sFileName.Substring(0, sFileName.LastIndexOf('\\')) + "\\" + Guid.NewGuid().ToString();
    ==================================
    however when I run the bulk load utility I get the error 
    =======================================
    Bulk load data conversion error (type mismatch or invalid character for the specified codepage) for row 1, column 3 (NumberOfMultipleMatches).
    ==========================================
    the bulk insert statement is as follows
    =========================================
     BULK INSERT Temp  
     FROM '<file name>' WITH  
      FIELDTERMINATOR = ','  
      , KEEPNULLS  
    ==========================================
    Does anybody know what is happening and what needs to be done ?
    PLEASE HELP
    Thanks in advance 
    Vikram

    To load that file with BULK INSERT, use this format file:
    9.0
    4
    1 SQLCHAR 0 0 "\""      0 ""    ""
    2 SQLCHAR 0 0 "\",\""   1 col1  Latin1_General_CI_AS
    3 SQLCHAR 0 0 "\",\""   2 col2  Latin1_General_CI_AS
    4 SQLCHAR 0 0 "\"\r\n"  3 col3  Latin1_General_CI_AS
    Note that the format file defines four fields while the fileonly seems to have three. The format file defines an empty field before the first quote.
    Or, since you already have a .NET program, use a stored procedure with table-valued parameter instead. I have an example of how to do this here:
    http://www.sommarskog.se/arrays-in-sql-2008.html
    Erland Sommarskog, SQL Server MVP, [email protected]

  • Movement Type 102, 122, 161

    Hello Experts,
    Please guide me regarding the use of movement type 102, 122 and 161 movement types.
    What are the scenarios where the above movement types should be used and what  are the reference documents to be used for all above processes.
    Also if QM is active then how to use these movement types.
    What are the accounting effect that went during posting with above mentioned movement types.
    Regards,
    Ashutosh

    Hi ,
    Please find the details of the movement types
    I) 101 Goods receipt for purchase order or order
    If the purchase order or order has not been assigned to an account, a stock type (unrestricted-use stock, stock in quality inspection, blocked stock) can be entered during goods receipt.
    If the purchase order or order has been assigned to an account, the goods receipt is not posted to the warehouse, but to consumption.
    In the case of non-valuated materials, the goods receipt is posted to the warehouse, although the purchase order has not been assigned to an account.
    Possible special stock indicators:
    o     K Goods receipt for purchase order to consignment stock
    o     O Goods receipt for purchase order to stock of material provided to vendor
    o     E GR for purchase order or order to
    o     sales order stock
    o     Q GR for purchase order or order to
    o     project stock.
    Goods receipt for subcontract order : at goods receipt, the consumption of the components is posted at the same time (see movement type 543)
    Goods receipt for
    stock transport order : at goods receipt the transported quantity is posted in the receiving plant from stock in transit into unrestricted-use stock (or stock in quality inspection, blocked stock).
    The cancellation or reversal of movement type 101 is the movement type  102.
    II) 122 - Return delivery to supplier or to production
    Using movement type 122, you can distinguish real return deliveries for a purchase order or order from cancellations (102).
    In the standard version, you must enter a reason for the return delivery if you are using movement type 122. In this way, evaluations of return deliveries are possible.
    The effects of movement type 122 correspond to a cancellation of movement type 101.
    III) 161 Return for purchase order
    If a purchase order item is marked as a returns item, the returns to vendor are posted using movement type 161 when the goods receipt for purchase order is posted.
    Movement type 161 has the same effects as movement type 122
    I think this may give clear idea about movement types
    Thanks,
    Arun G

Maybe you are looking for

  • Midi instrument stops playing when I move the mouse button

    Hi. Weirdest thing. All of a sudden, I started noticing some strange behavior with my midi input. 1) I can play a selection for a given software instrument, but, if I move the mouse, the midi input freezes (for lack of a better term). I am using logi

  • My microsoft account is not visible by other user

    Hi, Nobody can see find my miscrosoft account in Skype. Is there hidden button where I can make my microsoft account Id visible in search results? Thanks Andrew

  • Insert multiple rows with autoincrement id

    I need to insert multiple rows to a table which has an autoincrement PK (unique), e.g: Entity: public Class Entity{ @Id @GeneratedValue(strategy = GenerationType.IDENTITY) @Basic(optional = false) @Column(name = "id") Private Long id; Facade: @Persis

  • TestStand'​s container type from LabVIEW

    Hi, With a LabVIEW's VI, I'd would like to set a TestStand cointainer as a TDMS file properties. So i tried to get all the elements of my container using PropertyObject Class (ThisContext.AsPropertyObject) with this method :PropertyObject.GetValVaria

  • Why doesn't the pwdchangedtime attribute get created?

    In OID, I set up a password policy where passwords never expire. Then I create some users. Then, I change the password policy so passwords expire in 30 days. But, the passwords never expire for the users I previously created. I think it's because the