Error while refreshing  WEBi Report : Supplied XML Invalid

Hi,
I have a universe buit on BI query in production environment.
I changed the query in BI directly in PRD. The only chnage i did was ,unhide the keyfigure which was hidden originally as i wanted to see the data it brings in BEx analyzer.
Then i agian chaged that key figure to Hidden.
now the WEBi reports which are built on the universe which uses this bi qury is not getting refreshed.
It gives the error : Supplies XML invalid
I refreshed the Universe and Parsed it.there was 1 parsing erroe in Filter.Still i exported the universe.
Now generally the WEBI reports start working after re exporting the universe, but this time it is not working.
What can be done in this case.???
I dont think it is because of parsing error as i have exported the same universe earlier with same error and reports worked fine that time.
following  is in the WHERE section of the filter:
<FILTER KEY="[!V000006]"><CONDITION OPERATORCONDITION="Equal"><CONSTANT TECH_NAME="@Prompt('Posting date','D',,mono,free)"/></CONDITION></FILTER>

How you tried editing Webi report ?
Its possible that your changes to Bex query while propagated to Universe after structure refresh, have changed some of the objects, and that change is not in Webi report yet, you'll need to edit it and maybe re-map objects.....

Similar Messages

  • Database Error while refreshing webi report

    Hi,
    I am getting following error while refreshing webi report. And also all my scheduled webi reports are getting failed because of same issue. What would be the reason for this error.
    Regards,
    PRK

    Hi Praveen,
    As you are getting error 'IES10901' it is related to database connection issue.
    Find below link it might help you.
    Database error in Web I ( BO 4.0)
    check your universe connections to DB(ODBC connections).
    Regards,
    Samatha B.

  • Error while refreshing webi report

    SAP BO XI 3.1, when i am trying to refresh data in a webi report, its giving error, Invalid prompt definition contact BO admin WI 00005.
    Though i deleted all filters in Bex query, save the query, import universe, refresh univerese, save universe, export universe still webi report is  showing the same error, but if all the filters are removed it shouldn't show that error?
    After universe is refreshed clicked the check button it showed me 15 errors on filters with message Invalid prompt definiton, supplied XML doc is not valid.
    Can any one please help me out.
    Thanks.

    I am getting this error when i refresh the webi report.
    ERROR:
    Multiple query filters contain a prompt with the same text, but the
    prompts use a different opernd type or operator count of values. (WIS: 0015)
    I got answer for this error.
    The query has multiple prompts that display the      same message. Web Intelligence combines prompts with the same message and      displays the prompt once. If the operator defined for some of these prompts      requires you to enter one value while the operator in other prompts with the      same message requires you to enter multiple values, Web Intelligence cannot      combine the prompt.
    But can anyone please explain me what is the cause of error in brief? i didn't get what does prompt with same text means?

  • ORA-12500 error while refreshing webi report

    Hi All,
    The problem looks simple, but i am struck with this. I am trying to refresh a webi report in BO XI R3.1, it throws the error "DBD: ORA-12500: TNS:listener failed to start a dedicated server process". It looks like there is no issue with the tnsnames.ora and sqlnet.ora.whar could be the other cause for this issue ? Any input will be appreciated.  Thanks in advance.
    Thanks
    Raj

    Hi,
       You need to fix up the issue on the Oracle D/B side first prior to testing on WebI.
       Try this link, it explains the error encountered in more details.
                 http://ora-12500.ora-code.com/
       Simply put, can you use client tool (e.g. TOAD) to log into Oracle D/B using the same machine?
       Fix up the connection then WebI will work.
    Regards,
    Ken

  • Error while refreshing webi reports

    Hi
    I am getting the below error when i try to refresh my webi reports in prod/uat/qa/dev
    These reports are developed on my team mate's id .
    Please assist
    regards,
    mahi

    This means you are using SSO. Make sure you are using SAP Authentication(or the user has an sap auth alias assigned in cmc) to login and SSO is properly configured between BW and BO.
    SSO Configuration :
    http://wiki.scn.sap.com/wiki/display/BOBJ/Generate+keystore+and+certificate+for+SAP+BO+BI4.0
    Import SAP BO BI4.0 certificate into SAP BW - Business Intelligence (BusinessObjects) - SCN Wiki
    Setup of SAP SSO Service in SAP BO BI4.0 CMC - Business Intelligence (BusinessObjects) - SCN Wiki

  • Connection Error while refreshing webi reports

    Hi Gurus,
    When i am refreshing my webi rep i am getting the below error.. pls advice what to do.. attached is the services file... that im using
    thx
    mahi

    Hi Arijit,
    pls find the below screen... the services file type is not in .txt format.. any suggestions to proceed further..
    thx
    mahi

  • Error occured while refreshing webi report in bi system

    Dear Experts ,
    please look into my problem
    While refreshing WebI report in BIDEV system, we are getting the following error. The problem occurs only while refreshing the report.
    ERROR: a database error occured. the database error text is unable to connect to sap bw server incomplete logon data.. (wis10901)
    Regards

    HI ayur
    In the universe connection if the username and password is hardcoded then make sure those username and passwords are correct.
    else
    Make sure you are in the right BOX, for example if Universe is pointed to Prod, and you execute the report associated with that universe  in the Dev, then  that error will show up. So in universe connection find out to what BOX(dev, test, prod) it is pointed to and login to webI in the same BOX as universe pointed to and execute the report.
    It should work, if not please let us know.

  • WIS 10901 error while running WEBI Report but no error in the DESKI report

    Hi,
    Can anyone please help me to resolve this issue.
    we have recently migrated BOXIR2 - BOXI3.1. many of the reports are from SQL Server and Oracle databases.
    Oracle Database connection universe reports error:
    i'm getting WIS 10901 error while running WEBI report for some particular objects not for all the objects but the same time i could able to pull the same object in the DESKI.
    those particular objects having lenthy data's for ex:100 bytes. but i tried same 100bytes some other objects refreshing fine and displaying results.
    i don't know where we ar missing.
    SQL Server Connection universe reports:
    These reports are giving mismatched results from the original but the callculation are done by the reporter side by creating variables. other than that there are no issues with these reports.
    Please we are struggling lot on these issues, can anyone please help us.

    Hi,
    For your issue 2 check whether any filters used in XI  R2 are missing in XI R3. As during migration some filetrs might be missed. To check this in  slice and dice panel in both bo versions.
    Cheers,
    Suresh Aluri.

  • SharePoint 2010 Error while executing web part: System.Xml.Xsl.XslLoadException: XSLT compile error.

    Hello,
    I currently having a series of errors (18 issues) that are occurring under the below Correlation ID ad1a22f5-1ddb-4fa5-8487-143cb6fd0f9d
    I have listed (3) that are in the Web Parts category, this error/issue is causing several timed job to no longer work properly I have been trying to find the root cause for about a week now. If anyone has encountered a issue
    such as this one I'm open for suggestions.     
    (1)
    Error while executing web part: System.Xml.Xsl.XslLoadException: XSLT compile error. An error occurred at (1,475). ---> System.Net.WebException: The underlying connection was closed: Could not establish trust relationship for the SSL/TLS secure channel.
    ---> System.Security.Authentication.AuthenticationException: The remote certificate is invalid according to the validation procedure.     at System.Net.Security.SslState.StartSendAuthResetSignal(ProtocolToken message, AsyncProtocolRequest
    asyncRequest, Exception exception)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[] buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer,
    AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[] buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer,
    AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[] buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer,
    AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ForceAuthentication(Boolean receiveFirst, Byte[] buffer, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessAuthentication(LazyAsyncResult
    lazyResult)     at System.Threading.ExecutionContext.runTryCode(Object userData)     at System.Runtime.CompilerServices.RuntimeHelpers.ExecuteCodeWithGuaranteedCleanup(TryCode code, CleanupCode backoutCode, Object userData)    
    at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)     at System.Net.TlsStream.ProcessAuthentication(LazyAsyncResult result)     at System.Net.TlsStream.Write(Byte[]
    buffer, Int32 offset, Int32 size)     at System.Net.PooledStream.Write(Byte[] buffer, Int32 offset, Int32 size)     at System.Net.ConnectStream.WriteHeaders(Boolean async)     --- End of inner exception
    stack trace ---     at System.Net.HttpWebRequest.GetResponse()     at System.Xml.XmlDownloadManager.GetNonFileStream(Uri uri, ICredentials credentials)     at System.Xml.XmlUrlResolver.GetEntity(Uri
    absoluteUri, String role, Type ofObjectToReturn)     at Microsoft.SharePoint.WebPartPages.WSSXmlUrlResolver.GetEntity(Uri absoluteUri, String role, Type ofObjectToReturn)     at System.Xml.Xsl.Xslt.XsltLoader.CreateReader(Uri
    uri, XmlResolver xmlResolver)     at System.Xml.Xsl.Xslt.XsltLoader.LoadStylesheet(Uri uri, Boolean include)     at System.Xml.Xsl.Xslt.XsltLoader.LoadStylesheet(XmlReader reader, Boolean include)    
    --- End of inner exception stack trace ---     at System.Xml.Xsl.Xslt.XsltLoader.LoadStylesheet(XmlReader reader, Boolean include)     at System.Xml.Xsl.Xslt.XsltLoader.Load(Compiler compiler, Object stylesheet, XmlResolver
    xmlResolver)     at System.Xml.Xsl.Xslt.Compiler.Compile(Object stylesheet, XmlResolver xmlResolver, QilExpression& qil)     at System.Xml.Xsl.XslCompiledTransform.CompileXsltToQil(Object stylesheet, XsltSettings
    settings, XmlResolver stylesheetResolver)     at System.Xml.Xsl.XslCompiledTransform.LoadInternal(Object stylesheet, XsltSettings settings, XmlResolver stylesheetResolver)     at System.Xml.Xsl.XslCompiledTransform.Load(XmlReader
    stylesheet, XsltSettings settings, XmlResolver stylesheetResolver)     at Microsoft.SharePoint.WebPartPages.DataFormWebPart.LoadXslCompiledTransform(WSSXmlUrlResolver someXmlResolver)     at Microsoft.SharePoint.WebPartPages.DataFormWebPart.GetXslCompiledTransform()    
    at Microsoft.SharePoint.WebPartPages.DataFormWebPart.PrepareAndPerformTransform(Boolean bDeferExecuteTransform)
    (2)
    InnerException 1: System.Net.WebException: The underlying connection was closed: Could not establish trust relationship for the SSL/TLS secure channel. ---> System.Security.Authentication.AuthenticationException: The remote certificate is invalid according
    to the validation procedure.     at System.Net.Security.SslState.StartSendAuthResetSignal(ProtocolToken message, AsyncProtocolRequest asyncRequest, Exception exception)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[]
    buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[]
    buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[]
    buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ForceAuthentication(Boolean
    receiveFirst, Byte[] buffer, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessAuthentication(LazyAsyncResult lazyResult)     at System.Threading.ExecutionContext.runTryCode(Object userData)    
    at System.Runtime.CompilerServices.RuntimeHelpers.ExecuteCodeWithGuaranteedCleanup(TryCode code, CleanupCode backoutCode, Object userData)     at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback,
    Object state)     at System.Net.TlsStream.ProcessAuthentication(LazyAsyncResult result)     at System.Net.TlsStream.Write(Byte[] buffer, Int32 offset, Int32 size)     at System.Net.PooledStream.Write(Byte[]
    buffer, Int32 offset, Int32 size)     at System.Net.ConnectStream.WriteHeaders(Boolean async)     --- End of inner exception stack trace ---     at System.Net.HttpWebRequest.GetResponse()    
    at System.Xml.XmlDownloadManager.GetNonFileStream(Uri uri, ICredentials credentials)     at System.Xml.XmlUrlResolver.GetEntity(Uri absoluteUri, String role, Type ofObjectToReturn)     at Microsoft.SharePoint.WebPartPages.WSSXmlUrlResolver.GetEntity(Uri
    absoluteUri, String role, Type ofObjectToReturn)     at System.Xml.Xsl.Xslt.XsltLoader.CreateReader(Uri uri, XmlResolver xmlResolver)     at System.Xml.Xsl.Xslt.XsltLoader.LoadStylesheet(Uri uri, Boolean include)    
    at System.Xml.Xsl.Xslt.XsltLoader.LoadStylesheet(XmlReader reader, Boolean include)
    (3)
    InnerException 2: System.Security.Authentication.AuthenticationException: The remote certificate is invalid according to the validation procedure.     at System.Net.Security.SslState.StartSendAuthResetSignal(ProtocolToken message, AsyncProtocolRequest
    asyncRequest, Exception exception)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[] buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer,
    AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[] buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer,
    AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessReceivedBlob(Byte[] buffer, Int32 count, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.StartReceiveBlob(Byte[] buffer,
    AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ForceAuthentication(Boolean receiveFirst, Byte[] buffer, AsyncProtocolRequest asyncRequest)     at System.Net.Security.SslState.ProcessAuthentication(LazyAsyncResult
    lazyResult)     at System.Threading.ExecutionContext.runTryCode(Object userData)     at System.Runtime.CompilerServices.RuntimeHelpers.ExecuteCodeWithGuaranteedCleanup(TryCode code, CleanupCode backoutCode, Object userData)    
    at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)     at System.Net.TlsStream.ProcessAuthentication(LazyAsyncResult result)     at System.Net.TlsStream.Write(Byte[]
    buffer, Int32 offset, Int32 size)     at System.Net.PooledStream.Write(Byte[] buffer, Int32 offset, Int32 size)     at System.Net.ConnectStream.WriteHeaders(Boolean async)

    Hello,
    It seems that issue is related to certificate. Could you please upload certificate to central admin and make it trust.
    Just try this and see the result:
    http://social.technet.microsoft.com/Forums/en-US/cbc58585-1673-4c91-b8c1-1b95c339bbb7/could-not-establish-trust-relationship-for-the-ssltls-secure-channel?forum=fastsharepoint
    http://social.msdn.microsoft.com/Forums/en-US/7a7e56ba-6e95-4a84-9384-791818cce89d/the-underlying-connection-was-closed-could-not-establish-trust-relationship-for-the-ssltls-secure?forum=sharepointdevelopmentprevious
    http://www.infotext.com/help/sharepoint-could-not-estabilish-trust-relationship-for-the-ssltls-secure-channel-when-crawling-ssl-enabled-websites/
    If still face the issue then tell us more about your webparts and also confirm if you are facing same problem to other page and site.
    Hemendra:Yesterday is just a memory,Tomorrow we may never see
    Please remember to mark the replies as answers if they help and unmark them if they provide no help

  • Error while creting webi report on top of query ,using BO XI3.1

    Hi,
    I'm getting below error while creating webi report ,tried to applying some patches but no luck
    SAP021_sales value report
    a database error occured ,the data base error text is error in MDD darasetBW.getcelldata.system error in program CL_RSR_MDX_BXML_FLATENING and form ASSIGN_COMP_02(see long text) (WIS10901)
    Looking forward to your sugesstions.
    Thanks

    hi,
    Go through the below SAP Notes on the issue-
    SAP OSS Notes 1440912 and 1432162

  • Error when refreshing WEBI report with Universe Connection Type "SSO"

    Hi Experts:
    We are trying to refresh the Webi report in Infoview with Universe Connection set as "Use Single Sign On when refreshing the report at view time", so that we can leverage SAP OLAP authorization variable from Bex Query which the Universe is built on.
    However got the error of "incomplete logon data" after all the configurations done following below blogs:
    SNC Part 1
    /people/ingo.hilgefort/blog/2009/07/03/businessobjects-enterprise-and-client-side-snc-part-1-of-2
    SNC Part 2
    /people/ingo.hilgefort/blog/2009/07/03/businessobjects-enterprise-and-client-side-snc-part-2-of-2
    We already have Win AD SSO to SAP setup, and in BO CMC, Win AD user is mapped to SAP user ID.
    The SNC settings are:
    - AD Account: service.test.bobj (all lower-letters)
    - 32-bit gsslib on the BO server, and 64 bit on the BW server side.
    - SNC0: p:service.test.bobj at DOMAIN
    - SU01 --> BO_Service ; SNC: p:service.test.bobj at DOMAIN
    - Entitlement system tab --> username: BO_Service
    SNC Name: p:service.test.bobj at DOMAIN
    - SNC settings tab:
    SNC Lib: c:\winnt\gsskrb5.dll
    Mutual Authentication settings: p:SAPServiceBP0 at DOMAIN
    In CMC, the role can be imported if "RFC activated" option unchecked in SNC0.
    I found a few threads on the same topic, but they are all not answered:
    SNC Client side configuration error
    SNC Configuration Error: Incomplete logon Data
    Can you please provide details of the solution if you have impleted a same scenario successsfully, or any thoughts to help the investigation?
    Thanks in advance!
    Regards,
    Jonathan

    Hi Ingo,
    Sorry for taking so long to reply, we are trying to set up server side trust and enable SSO; but we still couldn't success.
    What we did is:
    1. We followed installation guide chapter 6, generate certificate and PSE, etc. All looks good.
    2. Then we still have the "incomplete logon data" error when refreshing webi report after logon using Windows AD user ID.
    3. Then we trace the PFC connection, the log is as below. We checked several BO notes, e.g. 1500150, 1461247.. The part bothers us is that we even don't have URI displayed in the log when system trying to use SNC, and we couldn't get more info on this which make us very difficult to diagnosis.
    Can you please help? Thanks a lot!
    Thu Mar 31 10:54:46.857 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Authentication model for SAP connectivity is SSO
    Thu Mar 31 10:54:46.857 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Determining if we can connect using SNC. Calling CanAuthenticate...
    Thu Mar 31 10:54:46.919 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Unable to authenticate using SNC because the URI does not meet the minimum connection requirements.
    Thu Mar 31 10:54:46.919 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Determining if we can connect using SSO. Calling CanAuthenticate...
    Thu Mar 31 10:54:46.919 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Authentication model for SAP connectivity is SSO
    Thu Mar 31 10:54:47.013 ThreadID<1980> SAPMODULE : SAPAuthenticationService: The SAP SSO authentication process will fail because the SAP secondary credential are not properly updated and the password is blank.
    Thu Mar 31 10:54:47.013 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Trying to connect to SAP using this URI : occa:sap://;PROVIDER=sapbw_bapi,R3NAME=PB0,GROUP=BI_Group1,MSHOST=sapaupdb04,LANG=en,CLIENT=100,CATALOG="ZSPUM602",CUBE="ZSPUM602/ZSPUM602_Q50"
    Thu Mar 31 10:54:47.013 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Calling m_pRfcWrapper->RfcOpenEx() ...
    Thu Mar 31 10:54:47.154 ThreadID<1980> SAPMODULE : SAPAuthenticationService: RfcOpenEx(...) returned 0
    Thu Mar 31 10:54:47.154 ThreadID<1980> SAPMODULE : SAPAuthenticationService: Call to m_pRfcWrapper->RfcOpenEx() took 0.141 seconds
    Thu Mar 31 10:54:47.154 ThreadID<1980> SAPMODULE : SAPAuthenticationService: SAPAuthenticationService::~SAPAuthenticationService

  • Error while executing webi report

    Hello Experts,
    I created a universe using SAP BI query. Now I am using this query to create webi report. so while creating webi report i select 1 characteristics and 1 key figure from the universe and putting them on result objects pane.
    After putting these object when I execute the report i get following error:
    Database error: SOFA Driver : Catastrophic failure. Contact your Business Objects administrator or database supplier for more information. (Error: WIS 10901)
    Can anyone suggest me how to resolve this error?
    Regards,
    Nirav Shah

    yes, underlying queries work perfectly fine. Universe are created without any issue. However,in WebI, when I drag the any TWO objects under any class or even combination of one object and one measurement key, as soon as I refresh query, the error pops up. If there is JUST ONE object, no issue at all. I can see the data.
    Mean...if there is more than one object in any WebI report, the error is thrown by WebI report. And this happens only while running WebI against SAP BW/BI, query or against any InfoCube.
    Thanks

  • Re : Java error while opening WEBI Report in BO 4.1

    Hi Team,
    while opening webi report i am getting folowing error
    java.util.concurrent.ExecutionException: java.lang.NullPointerException
    at java.util.concurrent.FutureTask.report(Unknown Source)
    at java.util.concurrent.FutureTask.get(Unknown Source)
    at javax.swing.SwingWorker.get(Unknown Source)
    at com.sap.webi.toolkit.ui.tasks.WebITask.getResult(WebITask.java:171)
    at com.sap.webi.ui.tasks.NavigOnDocumentTask.doneProcess(NavigOnDocumentTask.java:95)
    at com.sap.webi.toolkit.ui.tasks.WebITask$PrivateWorker.done(WebITask.java:378)
    at javax.swing.SwingWorker$5.run(Unknown Source)
    at javax.swing.SwingWorker$DoSubmitAccumulativeRunnable.run(Unknown Source)
    at sun.swing.AccumulativeRunnable.run(Unknown Source)
    at javax.swing.SwingWorker$DoSubmitAccumulativeRunnable.actionPerformed(Unknown Source)
    at javax.swing.Timer.fireActionPerformed(Unknown Source)
    at javax.swing.Timer$DoPostEvent.run(Unknown Source)
    at java.awt.event.InvocationEvent.dispatch(Unknown Source)
    at java.awt.EventQueue.dispatchEventImpl(Unknown Source)
    at java.awt.EventQueue.access$500(Unknown Source)
    at java.awt.EventQueue$3.run(Unknown Source)
    at java.awt.EventQueue$3.run(Unknown Source)
    at java.security.AccessController.doPrivileged(Native Method)
    at java.security.ProtectionDomain$1.doIntersectionPrivilege(Unknown Source)
    at java.awt.EventQueue.dispatchEvent(Unknown Source)
    at java.awt.EventDispatchThread.pumpOneEventForFilters(Unknown Source)
    at java.awt.EventDispatchThread.pumpEventsForFilter(Unknown Source)
    at java.awt.EventDispatchThread.pumpEventsForFilter(Unknown Source)
    at java.awt.WaitDispatchSupport$2.run(Unknown Source)
    at java.awt.WaitDispatchSupport$4.run(Unknown Source)
    at java.awt.WaitDispatchSupport$4.run(Unknown Source)
    at java.security.AccessController.doPrivileged(Native Method)
    at java.awt.WaitDispatchSupport.enter(Unknown Source)
    at java.awt.Dialog.show(Unknown Source)
    at com.jidesoft.dialog.StandardDialog.show(Unknown Source)
    at java.awt.Component.show(Unknown Source)
    at java.awt.Component.setVisible(Unknown Source)
    at java.awt.Window.setVisible(Unknown Source)
    at java.awt.Dialog.setVisible(Unknown Source)
    at com.sap.webi.toolkit.ui.dialog.MessageDialog.setVisible(MessageDialog.java:186)
    at com.sap.webi.ui.SwingClientHelper.showWarning(SwingClientHelper.java:493)
    at com.sap.webi.ui.context.managers.DataManager.checkForEmptyDataProviders(DataManager.java:2592)
    at com.sap.webi.ui.tasks.workflows.RefreshWorkspaceWorkflow$1.run(RefreshWorkspaceWorkflow.java:147)
    at java.awt.event.InvocationEvent.dispatch(Unknown Source)
    at java.awt.EventQueue.dispatchEventImpl(Unknown Source)
    at java.awt.EventQueue.access$500(Unknown Source)
    at java.awt.EventQueue$3.run(Unknown Source)
    at java.awt.EventQueue$3.run(Unknown Source)
    at java.security.AccessController.doPrivileged(Native Method)
    at java.security.ProtectionDomain$1.doIntersectionPrivilege(Unknown Source)
    at java.awt.EventQueue.dispatchEvent(Unknown Source)
    at java.awt.EventDispatchThread.pumpOneEventForFilters(Unknown Source)
    at java.awt.EventDispatchThread.pumpEventsForFilter(Unknown Source)
    at java.awt.EventDispatchThread.pumpEventsForHierarchy(Unknown Source)
    at java.awt.EventDispatchThread.pumpEvents(Unknown Source)
    at java.awt.EventDispatchThread.pumpEvents(Unknown Source)
    at java.awt.EventDispatchThread.run(Unknown Source)
    Caused by: java.lang.NullPointerException
    at com.sun.deploy.security.CPCallbackHandler.isAuthenticated(Unknown Source)
    at com.sun.deploy.security.CPCallbackHandler.access$1600(Unknown Source)
    at com.sun.deploy.security.CPCallbackHandler$ChildElement.checkResource(Unknown Source)
    at com.sun.deploy.security.DeployURLClassPath$JarLoader.checkResource(Unknown Source)
    at com.sun.deploy.security.DeployURLClassPath$JarLoader.getResource(Unknown Source)
    at com.sun.deploy.security.DeployURLClassPath.getResource(Unknown Source)
    at sun.plugin2.applet.Plugin2ClassLoader$2.run(Unknown Source)
    at sun.plugin2.applet.Plugin2ClassLoader$2.run(Unknown Source)
    at java.security.AccessController.doPrivileged(Native Method)
    at sun.plugin2.applet.Plugin2ClassLoader.findClassHelper(Unknown Source)
    at sun.plugin2.applet.Applet2ClassLoader.findClass(Unknown Source)
    at sun.plugin2.applet.Plugin2ClassLoader.loadClass0(Unknown Source)
    at sun.plugin2.applet.Plugin2ClassLoader.loadClass(Unknown Source)
    at sun.plugin2.applet.Plugin2ClassLoader.loadClass(Unknown Source)
    at java.lang.ClassLoader.loadClass(Unknown Source)
    at com.businessobjects.rebean.wi.impl.model.viewing.ReportEngineOutputSourceFactory.createReportElementPageOutputSource(ReportEngineOutputSourceFactory.java:72)
    at com.businessobjects.rebean.wi.impl.services.NavigationServiceImpl.internalNavigateToReportElement(NavigationServiceImpl.java:313)
    at com.businessobjects.rebean.wi.impl.services.NavigationServiceImpl.navigateToReportElement(NavigationServiceImpl.java:105)
    at com.businessobjects.rebean.wi.app.ViewingFacade.navigateToReportElement(ViewingFacade.java:208)
    at com.sap.webi.ui.viewer.PageFactory.getPages(PageFactory.java:634)
    at com.sap.webi.ui.viewer.PageFactory.getPages(PageFactory.java:196)
    at com.sap.webi.ui.tasks.NavigOnDocumentTask.doIt(NavigOnDocumentTask.java:68)
    at com.sap.webi.ui.tasks.NavigOnDocumentTask.doIt(NavigOnDocumentTask.java:23)
    at com.sap.webi.toolkit.ui.tasks.WebITask$PrivateWorker.doInBackground(WebITask.java:348)
    at javax.swing.SwingWorker$1.call(Unknown Source)
    at java.util.concurrent.FutureTask.run(Unknown Source)
    at javax.swing.SwingWorker.run(Unknown Source)
    at java.util.concurrent.ThreadPoolExecutor.runWorker(Unknown Source)
    at java.util.concurrent.ThreadPoolExecutor$Worker.run(Unknown Source)
    at java.lang.Thread.run(Unknown Source)
    Any ideas please,
    Thanks & Regards,
    Varun G

    "...at com.sap.webi.ui.tasks.NavigOnDocumentTask.doIt(NavigOnDocumentTask.java:23) at com.sap.webi.toolkit.ui.tasks.WebITask$PrivateWorker.doInBackground(WebITask.java:348)" Please check out SAP KB 2115770 - Error encountered when opening a Web Intelligence document reporting off of SAP BW BEx queries and Universes in BI 4.1 SP05 on http://service.sap.com/sap/support/notes/2115770. The resolution can be found on BI4.1 SP05 Patch 03 and above. Hope this helps, Jin-Chong

  • Error while running Webi report that uses Custom Dimension object(SAP BW)

    Hi,
    I have a universe that is based on SAP BW.I have created a custom dimension object that displays the maximum date.
    The object syntax is
    <expression>Max(@Select(CPS Online\Calendar day))</expression>
    The object parses successfully.
    The object 'Calendar Day ' is a defaultobject created during universe creation from the BW query.It is defined as [0CALDAY].[LEVEL01]
    I tried  to create a Webi report using this object and a measure .On running the query it throws the following error:
    A database error occured. The database error text is: The MDX query WITH MEMBER [Measures].[EBC10672-C0DA-4998-93,80,D3,FF,C3,E8,A2,22] AS ' Max{[0CALDAY].[LEVEL01]} '  SELECT  { [Measures].[EBC10672-C0DA-4998-93,80,D3,FF,C3,E8,A2,22], [Measures].[4JCOSFOKKCUR3RMBPNROFKQQD] }  ON COLUMNS , NON EMPTY [0CALDAY].[LEVEL01].MEMBERS DIMENSION PROPERTIES [0CALDAY].[20CALDAY] ON ROWS FROM [ZCCPSONL/ZCPSONLINE]  failed to execute with the error Invalid MDX command with (. (WIS 10901)
    I have tried every possible syntax I could think of but I keep getting this error each time.I have set the object type to Number (even though it is actually a Date), I have tried writing the MDX inside the Max instead of the @select , but nothing seems to work.Could anyone please let me know why this error is occuring?Is there anything wrong with the syntax or is there any setting in Webi needed before a custom dimension object can be used on it.

    Can you see data for Custom object @ BEx level??
    YES, then just try to re-create the same variable and Save the BW query.
    Now do View - refresh Strusture @ Universe. And you can see Filter for the same, just Parse it, just whether it is OK or not.
    OK -- then Export the Universe and create WebI reports, this will come as Prompt.
    Hope it will helps you.
    Thank You!!
    Sent from iPhone

  • Ping Error while refreshing webi in view/HTML mode

    Hi all,
    while refreshing a webi report from Infoview in XI R2 SP6, I'm getting the following error:
    Ping: Infoview cannot connect to the server. Close the report panel and try to connect again or see your Business Objects Administrator.
    If I click on OK, the the refresh of the LOV continues and data is refreshed.
    The error is not occuring if refreshing from the Java Report Panel.
    Have you ever seen this error?
    Can you help me please.
    Weblogic 8.1 SP4.
    Solaris 8.

    Hi,
    we were facing the same problem with InfoView in XI 3.1.
    in our case, it helped to increase the numeric default-value (20000  i.e. 20 Sec.) of the
      "<tt>ping_waitTimeoutID</tt>"
    in the JavaScript-file  "<tt>viewer.js</tt>"  in directory
    <tt>$/bobje/tomcat/webapps/AnalyticalReporting/viewers/cdz_adv/language/LANG/scripts/</tt>
    Where for this installation <tt> /LANG/</tt>* stands for "/de/" and "/en/".
      1665  function ping()
      1666  {
      1667  /* ping_waitTimeoutID=setInterval("checkTheConnectionn()",20000); */
      1668  ping_waitTimeoutID=setInterval("checkTheConnectionn()",80000);
      1669  }
    best regards,
    pkunk*

Maybe you are looking for

  • U201CRG23 Part II posting error

    Hello Gurus, 1. My client is created one PO with 100 qty on dated 13/05/2010 2. And he has done the 1st GR (101) with 50 qty on dated 13/05/2010 and posted pat1 and II, when I opened GR doc in MIGO in that excise invoice number 1481 and date is 23/03

  • Just did the update and now home sharing isnt working. Im getting error -9808. Any ideas??

    I have no idea what is happening. My wifes library shows up on my account as does mine on hers and songs will play but we cant drag them into the library. When I o to turn on home sharing on my account it hits me with error code -9808.

  • How to go back to ios6

    Hello! I did a big mistake and uploaded ios7 to my 4S. Now, after using my 4S couple of days, and being very very dissapointed, I want to go back to ios6. Ios7 is so awfull looking, difficult using, messy, uncomfortable, full of bugs, I really, reall

  • Why can't I get my facetime activated?

    Having trouble activating facetime? Every time I try signing in, I get "an error occured during activation".   Very frustrated. I created my Apple ID online...and still a no-go!!

  • Flash Player 14 : FLV alpha videos have black background!!!

    Please correct this bug. All flv videos with alpha are now played with a black background. It's work with all previous Flash player versions...