Get the form module version using JDAPI program

Hi
I have one problem to find the verison of form module using java (JDAPI) programming.
To the JDAPI program i am just passing the form name. by reading the form it has to say the form version.
Is there any method to get this...
Thanks in advance.
Madhava

I solved my problem...
first of all.
Versioning was enabled for the folder but apparently it didnt work so i disabled it and enabled it again. Then I got the correct reource instead of null.
second thing
later in mycode I used this to get the path of the resource
resource.getRID().getPath();
but this gives the path to where the version of the document can be found... something like /documents/~System/xx/xxxxx/xxxx
where x is numbers
after doing a little debugging I found out that
resource.getAccessRID().getPath()
returns the path to where in CM the resource is stored.
I hope My experience here can help others.
I am glad that I solved my problem, but I find it extremely worrying that some settings in CM apparently stops working without any apparent reason.
We have experienced this with other properties like Manual Ordering, Approval process, have any one else had these problems and found the cause then I would like to hear about it

Similar Messages

  • To get JRE or JDK version using Java Programs

    How do get JRE or JDK version using Java Programs?.
    Kindly Reply...
    By
    Mani

    If you're talking about current program's runtime environment (as opposed to all installed JDK/JRE) : System properties

  • Installing i-tunes i get the message "older version of bonjour cannot be removed". What to do? I have uninstalled all old itunes/apple programs

    My itunes crashed and I uninstalled all apple/itunes products (I thought) and tried a fresh install. When I install I get the message "older version of bonjour cannot be removed" or "bonjour.msi" not available. How do I reinstall itunes from here?

    When I install I get the message "older version of bonjour cannot be removed" or "bonjour.msi" not available.
    Unfortunately, this sort of trouble has gotten more complicated to deal with ever since Microsoft pulled the Windows Installer CleanUp utility from their Download Center. First we have to find a copy of the utility.
    Let's try Googling. (Best not to use Bing, I think.) Look for a working download site for at least version 3.0 of the Windows Installer CleanUp utility. (The results from mydigitallife and Major Geeks are worth checking.)
    After downloading the utility installer file (msicuu2.exe), scan the file for malware, just in case. (I use the free version of Malwarebytes AntiMalware to do single-file scans for that.)
    If the file is clean, to install the utility, doubleclick the msicuu2.exe file you've downloaded.
    Now run the utility ("Start > All Programs > Windows Install Clean Up"). In the list of programs that appears in CleanUp, select any Bonjour entries and click "Remove".
    Quit out of CleanUp. Restart the PC, and try another iTunes install. Does it go through properly this time?

  • I had firefox 3.6 and since I updated to 4.0 my computer is running much slower. I called my ISP and they cannot uninstall the 4.0 version. I play alot of POGO and it runs sooo slowly. I am using windows XP. Can you help me get the 3.6. version back?

    I would like to get the 3.6 version and uninstall the 4.0 version computer running slow

    Here's the process to roll back:
    First, I recommend backing up your Firefox settings in case something goes wrong. See [https://support.mozilla.com/en-US/kb/Backing+up+your+information Backing up your information]. (You can copy your entire Firefox profile folder somewhere outside of the Mozilla folder.)
    Next, download and save Firefox 3.6 to your desktop for future installation. http://www.mozilla.com/firefox/all-older
    Close Firefox 4.
    You could install Firefox 3.6 over it (many have reported success) or you could uninstall Firefox first. If you uninstall, do not remove your personal data and settings, just the program.
    Unless you have installed an incompatible add-on, Firefox 3.6 should pick up where you left off. If there are serious issues, please post back with details.
    Note: I haven't actually tried this myself!

  • I get the message 'ITunes has stopped working' whenever attempting to open iTune. The problem Event Name='APPCRASH'. The Fault Module Name=iTunes.dll. The fault module version=11.1.5.5. Anyone has a solution?

    I get the message 'ITunes has stopped working' whenever attempting to open iTune. The problem Event Name is 'APPCRASH'. The Fault Module Name is iTunes.dll. The fault module version is 11.1.5.5. Does anyone has a solution?

    Hello, philos188. 
    Thank you for visiting Apple Support Communities.
    Here are a couple troubleshooting articles that I would recommend going through.
    iTunes for Windows Vista, Windows 7, or Windows 8: Fix unexpected quits or launch issues
    http://support.apple.com/kb/ts1717
    iTunes for Windows: Unable to install or open
    http://support.apple.com/kb/ts5376
    Cheers,
    Jason H.

  • How to get the form name which is used in standard tcode like me23n in sap

    how to get the form name which is used in standard tcode like me23n in sap
    Moderator message: four out of four threads locked, please read and understand the following before posting further:
    [Rules of engagement|http://wiki.sdn.sap.com/wiki/display/HOME/RulesofEngagement]
    [Asking Good Questions in the Forums to get Good Answers|Asking Good Questions in the SCN Discussion Spaces will help you get Good Answers]
    Edited by: Thomas Zloch on Nov 18, 2011 1:32 PM

    how to get the form name which is used in standard tcode like me23n in sap
    Moderator message: four out of four threads locked, please read and understand the following before posting further:
    [Rules of engagement|http://wiki.sdn.sap.com/wiki/display/HOME/RulesofEngagement]
    [Asking Good Questions in the Forums to get Good Answers|Asking Good Questions in the SCN Discussion Spaces will help you get Good Answers]
    Edited by: Thomas Zloch on Nov 18, 2011 1:32 PM

  • Installed 11 64 bit now get  "The iPHone cannot be used because the required software is not installed.  Run the iTunes installer to remove iTunes, then install the 64-bit version of iTunes."

    Installed iTunes 11 64 bit now get  "The iPhone cannot be used because the required software is not installed.  Run the iTunes installer to remove iTunes, then install the 64-bit version of iTunes." Uninstalled and installed twice no help. windows 7 64 bit, iPhone 5 OS 5.1

    Let's try a standalone Apple Mobile Device Support install. It still might not install, but fingers crossed any error messages will give us a better idea of the underlying cause of why it's not installing under normal conditions.
    Download and save a copy of the iTunesSetup.exe (or iTunes64setup.exe) installer file to your hard drive:
    http://www.apple.com/itunes/download/
    Download and install the free trial version of WinRAR:
    http://www.rarlab.com/
    Right-click the iTunesSetup.exe (or iTunes64setup.exe), and select "Extract to iTunesSetup" (or "Extract to iTunes64Setup"). WinRAR will expand the contents of the file into a folder called "iTunesSetup" (or "iTunes64Setup").
    Go into the folder and doubleclick the AppleMobileDeviceSupport.msi (or AppleMobileDeviceSupport64.msi) to do a standalone AMDS install.
    (If it offers you the choice to remove or repair, choose "Remove", and if the uninstall goes through successfully, see if you can reinstall by doubleclicking the AppleMobileDeviceSupport.msi again.)
    Does it install (or uninstall and then reinstall) properly for you?
    If instead you get an error message during the install (or uninstall), let us know what it says. (Precise text, please.)

  • Can I get the former version of Firefox back? The updated version stalls while browsing several times a day. I then have to close and restart.

    Since updating Firefox, several times a day browsing will 'stall'. I have to close the browser and wait several minutes before I can restart it. Can I get the former version back? Please.

    Fx 3.6.19
    http://www.mozilla.com/en-US/firefox/all-older.html
    As a matter of interest what is this in your User Agent String? -
    GACID=dfc_1689; LTID=1689)

  • If I already own the retail box version of a program can i get it in the app store without paying

    If I already own the retail box version of a program can i get it in the app store without paying extra. for instance if I have Civ V can i utilize the mac app store to download extra content or redownload the game if i lose the disc?

    To swtch to the MAS for an app, wait for the next paid upgrade and if it is available in the MAS, buy it.

  • Hi guru's what are the function modules are used in ALV

    hi guru's what are the function modules are used in ALV

    Hi vasu,
    There are some function modules which will enable to produce the  reports without much effort.
    All the definitions of internal tables, structures and constants are declared in a type-pool called SLIS.
    1. SIMPLE REPORT.
    The important function modules are
    a. Reuse_alv_list_display
    b. Reuse_alv_fieldcatalog_merge
    c. Reuse_alv_events_get
    d. Reuse_alv_commentary_write
    e. Reuse_alv_grid_display
    A. REUSE_ALV_LIST_DISPLAY : This is the function module which prints the data.
    The important parameters are :
    I. Export :
    i. I_callback_program : report id
    ii. I_callback_pf_status_set : routine where a user can set his own pf status or change the functionality of the existing pf status
    iii. I_callback_user_command : routine where the function codes are handled
    iv. I_structure name : name of the dictionary table
    v. Is_layout : structure to set the layout of the report
    vi. It_fieldcat : internal table with the list of all fields and their attributes which are to be printed (this table can be populated automatically by the function module REUSE_ALV_FIELDCATALOG_MERGE
    vii. It_events : internal table with a list of all possible events of ALV and their corresponding form names.
    II. Tables :
    i. t_outtab : internal table with the data to be output
    B. REUSE_ALV_FIELDCATALOG_MERGE : This function module is used to populate a fieldcatalog which is essential to display the data in ALV. If the output data is from a single dictionary table and all the columns are selected, then we need not exclusively create the field catalog. Its enough to mention the table name as a parameter(I_structure name) in the REUSE_ALV_LIST_DISPLAY. But in other cases we need to create it.
    The Important Parameters are :
    I. Export :
    i. I_program_name : report id
    ii. I_internal_tabname : the internal output table
    iii. I_inclname : include or the report name where all the dynamic forms are handled.
    II Changing
    ct_fieldcat : an internal table with the type SLIS_T_FIELDCAT_ALV which is
    declared in the type pool SLIS.
    C. REUSE_ALV_EVENTS_GET : Returns table of possible events for a list type
    Parameters :
    I. Import :
    Et_Events : The event table is returned with all possible CALLBACK events
    for the specified list type (column 'NAME'). For events to be processed by Callback, their 'FORM' field must be filled. If the field is initialized, the event is ignored. The entry can be read from the event table, the field 'FORM' filled and the entry modified using constants from the type pool SALV.
    II. Export :
    I_List_type :
    0 = simple list REUSE_ALV_LIST_DISPLAY
    1 = hierarchcal-sequential list REUSE_ALV_HIERSEQ_LIST_DISPLAY
    2 = simple block list REUSE_ALV_BLOCK_LIST_APPEND
    3 = hierarchical-sequential block list
    REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_COMMENTARY_WRITE : This is used in the Top-of-page event to print the headings and other comments for the list.
    Parameters :
    I. it_list_commentary : internal table with the headings of the type slis_t_listheader.
    This internal table has three fields :
    Typ : ‘H’ – header, ‘S’ – selection , ‘A’ - action
    Key : only when typ is ‘S’.
    Info : the text to be printed
    E. REUSE_ALV_GRID_DISPLAY : A new function in 4.6 version, to display the results in grid rather than as a preview.
    Parameters : same as reuse_alv_list_display
    This is an example for simple list.
    2. BLOCK REPORT
    This is used to have multiple lists continuously.
    The important functions used in this report are:
    A. REUSE_ALV_BLOCK_LIST_INIT
    B. REUSE_ALV_BLOCK_LIST_APPEND
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    A. REUSE_ALV_BLOCK_LIST_INIT
    Parameters:
    I. I_CALLBACK_PROGRAM
    II. I_CALLBACK_PF_STATUS_SET
    III. I_CALLBACK_USER_COMMAND
    This function module is used to set the default gui status etc.
    B. REUSE_ALV_BLOCK_LIST_APPEND
    Parameters :
    Export :
    I. is_layout : layout settings for block
    II. it_fieldcat : field catalog
    III. i_tabname : internal table name with output data
    IV. it_events : internal table with all possible events
    Tables :
    i. t_outtab : internal table with output data.
    This function module adds the data to the block.
    Repeat this function for all the different blocks to be displayed one after the other.
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    This function module is used for hierarchical sequential blocks.
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    Parameters : All the parameters are optional.
    This function module display the list with data appended by the above function.
    Here the functions REUSE_ALV_FIELDCATALOG_MERGE, REUSE_ALV_EVENTS_GET, REUSE_ALV_COMMENTARY_WRITE can be used.
    3. Hierarchical reports :
    Hierarchical sequential list output.
    The function module is
    A. REUSE_ALV_HIERSEQ_LIST_DISPLAY
    Parameters:
    I. Export:
    i. I_CALLBACK_PROGRAM
    ii. I_CALLBACK_PF_STATUS_SET
    iii. I_CALLBACK_USER_COMMAND
    iv. IS_LAYOUT
    v. IT_FIELDCAT
    vi. IT_EVENTS
    vii. i_tabname_header : Name of the internal table in the program containing the
    output data of the highest hierarchy level.
    viii. i_tabname_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    ix. is_keyinfo : This structure contains the header and item table field
    names which link the two tables (shared key).
    II. Tables
    i. t_outtab_header : Header table with data to be output
    ii. t_outtab_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    slis_t_fieldcat_alv : This internal table contains the field attributes. This internal table can be populated automatically by using ‘REUSE_ALV_FIELDCATALOG_MERGE’.
    Important Attributes :
    A. col_pos : position of the column
    B. fieldname : internal fieldname
    C. tabname : internal table name
    D. ref_fieldname : fieldname (dictionary)
    E. ref_tabname : table (dictionary)
    F. key(1) : column with key-color
    G. icon(1) : icon
    H. symbol(1) : symbol
    I. checkbox(1) : checkbox
    J. just(1) : (R)ight (L)eft (C)ent.
    K. do_sum(1) : sum up
    L. no_out(1) : (O)blig.(X)no out
    M. outputlen : output length
    N. seltext_l : long key word
    O. seltext_m : middle key word
    P. seltext_s : short key word
    Q. reptext_ddic : heading (ddic)
    R. ddictxt(1) : (S)hort (M)iddle (L)ong
    S. datatype : datatype
    T. hotspot(1) : hotspot
    some theory regarding alv:
    This table tells ALV which events are processed by the caller by CALLBACK.
    The table of possible events per list type can be initialized using the module REUSE_ALV_EVENTS_GET.
    You can display the names of the constants in the type pools SLIS which represent the individual events using the individual test function in the function module
    REUSE_ALV_EVENT_NAMES_GET. Only events with a form routine name are processed.
    The table structure contains the fields:
    • IT_EVENTS-NAME
    Name of the Callback event.
    Possible Callback events:
    • Action
    USER_COMMAND USING R_UCOMM LIKE SY-UCOMM RS_SELFIELD TYPE SLIS_SELFIELD
    Process actions on the list
    As this is a frequently-used Callback event, the form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_USER_COMMAND.
    PF_STATUS_SET USING RT_EXTAB TYPE SLIS_T_EXTAB
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a template for a user-specific status.
    As this is a frequently-used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    ITEM_DATA_EXPAND USING RS_SELFIELD TYPE SLIS_SELFIELD RFLG_ALL TYPE C
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT.
    Exit for passing item entries (ITEM table) for a header record which was expanded interactively by the user.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header which is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that entries are not repeated in the item table. RS_SELFIELD is initial in this case.
    CALLER_EXIT USING RS_DATA Is called at the beginning of the function module to make special settings. It is not usually used.
    • List processing events
    IMPORTANT: The application Callback routine must not manipulate the internal output table and/or its header record. This restriction applies to all Callbacks which are called in the list output and run under the 'List processing events'.
    TOP_OF_LIST no USING parameter. Information output at the start of the list
    END_OF_LIST no USING parameter. Information output at the end of the list
    TOP_OF_PAGE no USING parameter
    Equivalent to the list processing TOP-OF-PAGE event
    END_OF_PAGE no USING parameter. Not available for hierarchical-sequential lists.
    Information output at the end of a page. This is only called for printing.
    TOP_OF_COVERPAGE no USING parameter
    The selection information and list status are output together (if they exist) on a separate page by default. See also the documentation of the parameters:
    IS_PRINT-NO_COVERPAGE
    IS_PRINT-NO_PRINT_SELINFOS
    IS_PRINT-NO_PRINT_LISTINFOS
    IS_LAYOUT-GET_SELINFOS
    The user can format the header area of the 'cover page' himself or herself by specifying a Callback routine for this event.
    END_OF_COVERPAGE no USING parameter
    Analogously to TOP_OF_COVERPAGE the user can add other information to the information output by ALV (selection information, list status) at this event.
    FOREIGN_TOP_OF_PAGE no USING parameter
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    FOREIGN_END_OF_PAGE no USING parameter
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.
    BEFORE_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.
    AFTER_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    • Internal use only
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
    R_INDEX LIKE SY-TABIX
    R_INDEX_ITEM LIKE SY-TABIX
    R_INDEX_SUM LIKE SY-TABIX
    • IT_EVENTS-FORM
    Name of the form routine which should be called in the calling program at the event.
    Field_catalog:
    Field catalog with field descriptions
    2.7.1. Description
    Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields). A field catalog is required for every ALV list output.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module
    See also the documentation of the function module REUSE_ALV_FIELDCATALOG_MERGE.
    The minimal field catalog is documented under 'default'. The caller can use the other optional parameters to assign output attributes to a field which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    • The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE.
    • all fields in this structure are to be output
    • the structure name is passed to ALV in the parameter I_STRUCTURE_NAME.
    See also the documentation of the IMPORTING paramter I_STRUCTURE_NAME.
    Positioning
    • row_pos (row position)
    value set: 0, 1 - 3
    Only relevant if the list output is to be multi-line (two or three lines) by default.
    A multi-line list can also be defined by the user interactively if the default list is one-line.
    The parameter specifies the relative output line of the column in a multi-line list.
    • col_pos (column position)
    value set: 0, 1 - 60
    only relevant when the default relative column positions differ from the field catalog field sequence. The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the field catalog field sequence.
    Identification
    • fieldname (field name)
    value set: internal output table field name (required parameter)
    Name of the internal output table field which is described by this field catalog entry
    • tabname (internal output table)
    value set: SPACE, internal output table name
    This parameter is used in 'manual' field catalog build-up only for hierarchical-sequential lists.
    Name of the internal output table which contains the field FIELDCAT-FIELDNAME.
    Data Dictionary reference
    • ref_fieldname (reference field name)
    value set: SPACE, Data Dictionary field name
    Name of the Data Dictionary field referred to.
    This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
    • ref_tabname (reference table/structure field name)
    value set: SPACE, name of a Data Dictionary structure or table
    Structure or table name of the referred Data Dictionary field.
    This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Reference to fields with currency/measurement unit
    Each internal output table sum or quantity field whose decimal places are to be formatted appropriately for the unit in the list must follow the convention:
    • the field is of data type QUAN or CURR (internal type P) (the field must really have this physical data type. Overwriting the physical data type with the parameter FIELDCAT-DATATYPE has no effect)
    • There is a field in the internal output table which contains the associated unit.
    • There is also an entry in the field catalog for the unit field.
    (If the unit is not to appear as a column in the list, and cannot be interactively displayed as a column, e.g. because it is always unambiguous and is therefore explicitly output by the caller in the list header, the field catalog units field entry can take the parameter FIELDCAT-TECH = 'X'.
    The association of a value field to a unit affects the output as follows:
    • appropriate decimal places display for the unit
    • an initialized field with a link to a non-initial unit is output as '0' for the unit (if FIELDCAT-NO_ZERO is initial). When this field is summed, this unit affects whether the units are homogeneous.
    • an initialized field with a link to an initial unit is output as SPACE. When this field is summed, the unit SPACE does not affect the homogeneity of the units.
    • When non-initial fields with an initial unit are summed, the unit SPACE is considered to be a unit.
    Link to currency unit
    • cfieldname (currency unit field name)
    value set: SPACE, output table field name
    Only relevant for amount columns with associated unit.
    Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    • ctabname (internal currency unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Link to measurement unit
    • qfieldname (measurement unit field name)
    value set: SPACE, output table field name
    only relevant for quantity columns with unit link.
    Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME.
    The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    • qtabname (internal measurement unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Column output options
    • outputlen (column width)
    value set: 0 (initial), n
    For fields with a Data Dictionary link this parameter can be left initial.
    For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    initial = column width is the output length of the referred Data Dictionary field (domain).
    n = column width is n characters
    • key (key column)
    value set: SPACE, 'X' 'X' = kex field (key field output in color)
    Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
    For exceptions see the documentation of the FIELDCAT-KEY_SEL parameter.
    • key_sel (hideable key column)
    value set: SPACE, 'X'
    only relevant when FIELDCAT-KEY = 'X'
    Key field which can be hidden interactively.
    The key column sequence cannot be changed interactively by the user.
    The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    • no_out (field in field list)
    value set: SPACE, 'X' 'X' = field is not displayed in the current list.
    The user can interactively choose the field for output from the field list.
    The user can display the contents of these fields at line level using the 'Detail' function.
    See also the 'Detail screen' documentation of the parameter IS_LAYOUT.
    • tech (technical field)
    value set: SPACE, 'X' 'X' = technical field
    Field cannot be output in the list and cannot be displayed interactively.
    Field can only be used in the field catalog (not in IT_SORT, ...).
    • emphasize (highlight columns in color)
    value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off '1'=on)
    'X' = column is colored with the default column highlight color.
    'Cxyz' = column is colored with a coded color:
    • C: Color (coding must begin with C)
    • x: color number
    • y: bold
    • z: inverse
    • hotspot (column as hotspot)
    value set: SPACE, 'X'
    'X' = column cells are output as hotspots
    • fix_column (fix column)
    value set: SPACE, 'X'
    Not relevant for block lists (output of several lists consecutively)
    'X' = column fixed (does not scroll horizontally)
    All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively. See also the documentation of the Layout parameter
    IS_LAYOUT-NO_KEYFIX of the IMPORTING paramter IS_LAYOUT.
    • do_sum (sum over column)
    value set: SPACE, 'X' 'X' = a sum is to be calculated over this internal output table field.
    This function can also be called by the user interactively.
    • no_sum (sums forbidden)
    value set: SPACE, 'X' 'X' = no sum can be calculated over this field, although the data type of the field would allow summing.
    • input (column ready for input)
    Function not available
    Format column contents
    • icon
    value set: SPACE, 'X' 'X' = column contents to be output as an icon.
    The caller must consider the printability of icons.
    • symbol
    value set: SPACE, 'X' 'X' = column contents are to be output as a symbol.
    The internal output table column must be a valid symbol character.
    The caller must consider the printability of symbols.
    Symbols can usually be printed, but may not always be output correctly, depending on the printer configuration.
    • just (justification)
    value set: SPACE, 'R', 'L', 'C'
    Only relevant for fields of data type CHAR or NUMC
    ' ' = default justification for this data type
    'R' = right-justified output
    'L' = left-justified output
    'C' = centered output
    The justification of the column header always follows the justification of the columns. Independent justification of the column neader is not possible.
    • lzero (leading zeros)
    value set: SPACE, 'X'
    Only relevant for fields of data type NUMC
    ALV outputs NUMC fields right-justified without leading zeros by default.
    'X' = output with leading zeros
    Note: If a NUMC field is output left-justified or centered by FIELDCAT-JUST, leading zeros are output. If the output of leading zeros is suppressed by a Data Dictionary reference ALPHA conversion exit, the output is always left-justified.
    • no_sign (no +/- sign) Only relevant for value fields
    value set: SPACE, 'X' 'X' = value output without +/ sign
    • no_zero (suppress zeros) Only relevant for value fields
    value set: SPACE, 'X' 'X' = suppress zeros
    • edit_mask (field formatting)
    value set: SPACE, template
    template = see documentation of WRITE formatting option USING EDIT MASK template
    The output conversion conv can be made by template = '== conv'.
    Texts
    The following text parameters should be specified for program fields without a Data Dictionary reference. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored. If the user changes the column width interactively, the column header text with the appropriate length is always used. The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
    The 'long field label' is also used in display variant definition, sort, etc. popups.
    • seltext_l (long field label)
    • seltext_m (medium field label)
    • seltext_s (short field label)
    • reptext_ddic (header)
    analogous to the Data element maintenance 'Header'
    The specified text is not necessarily output in the list, an optimum among all texts is sought.
    • ddictxt (specify text)
    value set: SPACE, 'L', 'M', 'S'
    You can specify with values 'L', 'M', and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Parameters for program fields without Data Dictionary reference
    see also 'Text' parameters
    • datatype (data type)
    value set: SPACE, Data Dictionary data type (CHAR, NUMC,...)
    Only relevant for fields without Data Dictionary reference
    Program field data type
    • ddic_outputlen (external output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    • FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    • FIELDCAT-INTLEN = n
    see also the documentation of the parameter FIELDCAT-INTLEN
    n = external format field output length
    The column width FIELDCAT-OUTPUTLEN need not be the same as the external format output length (FIELDCAT-DDIC_OUTPUTLEN).
    • intlen (internal output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    • FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    • FIELDCAT-DDIC_OUTPUTLEN = n
    see also the documentation of the parameter FIELDCAT-DDIC_OUTPUTLEN
    n = internal format field output length
    • rollname (data element)
    value set: SPACE, Data Dictionary data element name
    F1 help can be provided for a program field without a Data Dictionary reference, or F1 help which differs from the Data Dictionary help can be provided for a field with a Data Dictionary reference, using this parameter.
    When F1 help is called for this field, the documentation of the specified data element is displayed.
    If the FIELDCAT-ROLLNAME is initial for fields with a Data Dictionary reference, the documentation of the data element of the referred Data Dictionary field is output.
    Others
    • sp_group (field group key)
    value set: SPACE, CHAR(1)
    Field group key.
    Keys are assigned to group names in the IT_SPECIAL_GROUPS parameter (see also the documentation of the parameter IT_SPECIAL_GROUPS).
    When such an assignment is made in the field catalog and in IT_SPECIAL_GROUPS, the fields are grouped correspondingly in the display variant popup.
    • reprep (Report/Report interface selection criterion)
    value set: SPACE, 'X'
    Prerequisites:
    • The system contains the Report/Report interface (function group RSTI, table TRSTI)
    • Parameter LAYOUT-REPREP = 'X'
    (see also the documentation of the parameter LAYOUT-REPREP of the IMPORTING parameter IS_LAYOUT )
    'X' = When the Report/Report interface is called, the value of this field is passed in the selected interface start record as a selection criterion.
    2.7.2. Default
    • The following entries are usually sufficient for internal table fields with a reference to a field defined in the Data Dictionary :
    • fieldname
    • ref_tabname
    Notes:
    ALV gets the remaining information from the Data Dictionary.
    If no relative column position (COL_POS) is specified, the fields are output in the list in the order in which they were added to the field catalog.
    REF_FIELDNAME need only be specifid when the name of the internal table field differs from the name of the referred Data Dictionary field.
    Information which is explicitly entered in the field catalog is not overwritten by information from the Data Dictionary.
    Priority rule:
    Entries in the field catalog have priority over differing entries in the Data Dictionary.
    • The following entries are usually sufficient for internal table fields without a reference to the Data Dictionary (program fields):
    • fieldname
    • outputlen
    • datatype
    • seltext_s
    • seltext_m
    • seltext_l
    Notes:
    F1 help can be provided for program fields by assigning a data element to the parameter ROLLNAME.
    If the parameters SELTEXT_S, SELTEXT_M, SELTEXT_L, and REPTEXT_DDIC contain appropriate field labels, the program field column headers are also adjusted appropriately when the column width changes
    sites :
    http://www.sapdevelopment.co.uk/reporting/alv/alv_variousfcat.htm
    <b>plese reward if useful </b>
    Message was edited by:
            sunil kairam

  • VGS-1501 Error while opening the canvas in the form module

    Hi All,
    I am getting “VGS-1501: <message not found>” message while opening the canvas. Actually in my machine Oracle Apps R12 is installed. To work on forms I have opened form builder and created a data block manually and created a canvas in the form module manually. To add items on the canvas, when I am clicking on canvas then first I am getting “VGS-1501: <message not found>” error message and then after canvas is getting opened. But here in the canvas there were no items available in the side tool bar.
    Then I decided to build form through wizard. Once the form was created, then when I opened the canvas then again I got the same error message. Here when I tried to run the form, then the form got closed automatically. This problem is related to forms only because I am able to work on Oracle Apps (functionally) and also I am able to develop a report using report builder. Can somebody please help me to fix this issue
    Thanks
    Thahessen

    I got something sililar behaviour when I use different version forms in different version of developer environment. Sometimes your Forms_PATH and REPORTS_PATH may be point ot wrong version.
    This is only a assumption...

  • AnyConnect - Posture Assessment Failed: Unable to get the available CSD version....

    Hello all
    I am attempting to get the HostScan posture assessment working so we can check that any device connecting to the ASA is a valid corporate asset.
    I have installed the posture module onto our test client machine (Windows 8.1) using the following software:
    anyconnect-posture-win-4.0.00061-pre-deploy-k9
    Then in ASDM under Remote Access VPN > Host Scan Image I have uploaded the following package:
    disk0:/hostscan_3.1.06073-k9.pkg
    ...and ticked the box 'Enable Host Scan/CSD'.
    Under Remote Access VPN > Secure Desktop Manager I have configured an initial simple Prelogin policy to test it working, this simply just checks that the OS is Windows 8. A success should map this user to a Group Policy I have created that is mapped to a Connection Profile. 
    So, with all that said, when I try to connect I see that the AnyConnect client going through the motions: "Posture Assessment: Checking for updates....", after which I get a pop-up and error message:
    "Posture Assessment Failed: Unable to get the available CSD version from the secure gateway"
    A bit stumped here and haven't quite found much on the web as to how to resolve this.
    Has anyone encountered this before? If so, can you advise on what I can do
    By the way I am connecting using IKEv2 (IPsec) as these are the requirements and the AC version is 4.0.00061, ASA version: 9.2(1).
    Many thanks

    Hello
    Please forgive the shameless bump. Was hoping someone could help?
    Many thanks

  • Can't get the nvidia module to work.

    Hi,
    I just moved a machine from debian to archlinux due to the newer packages. Anyways, since yesterday I have been trying to get the nvidia module to work but haven't had no luck. Basically I get a black screen once I run startx and afterwards I can't switch back to any of the consoles. The system doesn't hang because I can SSH into it from another machine and do whatever. Killing all the x-related processes doesn't recover the screen, only restarting the computer gets the ttys back.
    I have tried several different nvidia module versions include 1.0-7664, 1.0-7174 and 1.0-6229. I have also the stock 2.6.11.10 kernel and a custom compiled 2.6.11.11 kernel. If that wasn't enough I have tried the xorg generated xorg.conf file and the hwd generated xorg.conf file. Below is what I am running.
    xorg 11R6.8.2-2
    eVGA nVidia GeForce FX5200 (The LCD is connected through the regular VGA port)
    xorg.conf: http://68.190.122.245:9696/temp/xorg.conf
    Xorg.0.log: http://68.190.122.245:9696/temp/Xorg.0.log
    nvidia-installer.log: http://68.190.122.245:9696/temp/nvidia-installer.log
    `hwd -s` output: http://68.190.122.245:9696/temp/hwd_s.txt
    Any help is really appreciated! 

    Nice to see logs and confs posted
    just to be sure we are singing from the same hymnbook, have you:
    -- followed the wiki info  as your logs show the DRI section still intact (bottom of xorg.conf)
    and from wiki,
    -- installed nvidia via pacman, with X server shut down. and then modified xorg.conf accordingly.
    # Auto-generated by Archie mkxcfg
    ? Archie ?
    -- following the kernel upgrade did you then run pacman -S nvidia, as above,  to incorporate it with the new kernel ?
    other tidbits
    maybe try backing up xorg.conf first and then removing redundant lines #'s etc to make your config file more readable, and 1, 4, 15 bit resolution entries too.
    The last time i had the blackscreen was in Fedora, it was mentioned that a kernel patch by fedora, was fouling the nvidia drivers. So i blamed fedora, chipsets, patches, drivers, witchcraft etc. Swapped to arch , followed the WIKI destructions and all worked ok. so im sure it can be solved here too.
    FWIW my xorg.conf can be found here  if you want something to refer to. in the interests of jurisprudence, copy/modify at your own risk.  i cant/wont pay for fried monitors
    incidentally nv in the Section did work for me instead of nvidia but was no real solution as i wanted to use GL and it wouldnt work with it, just runs a generic vga driver and not the nvidia one.
    persevere dude, and good luck.

  • How to get the full path of a specific programe(flash media live encoder in my case) in air?

    I need to call it in air,but first of all how can I figure out where it's installed programatically?

    If you are using the d2kwutil library, then you can use the win_api_environment.Get_Working_Directory() function.
    If not, I doubt that there is anyway to get it since the get_application_property(current_form) does not return the full path of the form as it used to in prior versions of Oracle forms such as 4.5.

  • When I try to install QuickTime, I get the message "newer version is already installed". How can I do?

    When I try to install QuickTime, I get the message "newer version of QuickTime already installed". I uninstalled QuickTime. I have also gone into the registry and deleted all references regarding QuickTime. I really don't want to have to reinstall Windows just to be able to install QuickTime. I have used QuickTime for years and want to use it again. What do you suggest I do?

    Download the Windows Installer CleanUp utility from the following page (use one of the links under the "DOWNLOAD LOCATION" thingy on the Major Geeks page):
    http://majorgeeks.com/download.php?det=4459
    To install the utility, doubleclick the msicuu2.exe file you downloaded.
    Now run the utility ("Start > All Programs > Windows Install Clean Up").
    In the list of programs that appears in CleanUp, select any QuickTime entries and click "Remove", as per the following screenshot:
    Quit out of CleanUp, restart the PC. Now try another QuickTime install. Does it go through properly this time?

Maybe you are looking for

  • Printer control app for iphone

    is it possible to roll back to a previous version of the Printer Control app for iphone?  I recently and stupidly updated the HP Printer Control app when offered through itunes on October 30 and have lost all the functionality I previously had to pri

  • How to explode Vendor wise BOM in PO for subcontracting?

    Hi, In subcontracting process we issue cloth to subcontractor for stiching the trouser. There are two vendors for this. One require 115cm of cloth and other vendor needs 120cm of cloth. We have created two BOM, one alternate BOM for 115cm and another

  • Source list

    Hello, is there a possibilty in the source list next to the field vendor, to display the field vendor name. I am asking if there is a possibility in standrad sap and not z. Thanks.

  • Securing table group SS / transaction SCC1 and table CCCFLOW

    Hello all, I'm relatively new to this forum, please be kind. Situation sketch: In an SAP landscape, in Development environment, I have 3 clients, in which 500 is the ECC golden client, 510 is for sandboxing and 520 is for testing. Problem: Developers

  • How do I apply the blur filter to all my layers at the same time?

    Hi I'm working on a background for a web page and I want to try how different filters are going to affect all the layers. Is it possible to apply a filter to all the layers without flattening the file first? Thanks very much, Cathy