High priority issue

Hi,
I have configured the workflow mailer but iam unable to receive the mails and also the workflow notification mailer has stopped with error
The Workflow Document Web Services Service,Workflow Mailer Service
The Workflow Agent Listener Service, remains to be started and thier services are activated
When i start the workflow notification mailer i got the error as
An error has occured
"The service Component Container is nor running".Please say me how to solve the error

Pl see your duplicate post here - workflow mailer
Srini

Similar Messages

  • CostCenter Group Aggregation problem. High Priority Issue.

    Hi Experts,
    I have very crital issue in the report, Help needed.
       I had some kind of requirement in one of the Overhead cost report, need to combine the COPA data and Costcenter(Over Head cost) data.  I have a problem with Costcenter Group aggregation on the report.
    I have Restricted 2-Keyfigures  want to derive the 3rd Keyfigure values. I given the below exmaple of the data. In my report I just want to display the KeyFigure(KF-A,B,C). I dont want to Display the Cost Center group/Costcenter Number in my report. My report ouput will be one line. But If I removed the costcenter Group I am seeing different values of the Keyfigure C, If I display the Costcenter comng with differnt Values. I am expecting the values in the column C is 1400 but it is coming like 3600.
    Please guide me how to design the Keyfigures if I want to get the value 1400 in theKeyFigre C with out Showing the Costcenter In the report.
    Cost-Center Group  R00048                         
                      Costcenter     KF-A     KF-B           KF-C
         10113     10     10          100
         10114     20     20          400
         10115     30     30          900
              60     60          1400(Insted of this its comming like 3600)
    Appreciate the response.
    Thanks,
    Venkata

    Hi,
    Check the display properties of key figure in Query Designer/Info object level.
    Set the property accordingly.
    I hope it will help.
    Thanks,
    S

  • High priority bug to be solved very  urgent

    Hello Experts,
    I need your help and plz close this topic once its solved.
    Here is the problem:
    There is  report called "Material Group".When its is displayed for  material gorup say "GB06010000" is displayed as part of report data wheras the source system (oracle ) does not have this item any more in the catalog. This indicated that data is not refreshed for quite a long time.
    This report is connected to the third party application (oracle db) not EBP system(r/3). Time to time there has been deletion  or addition  catalog items and in all as of today there are 815 items, whereas BIW report displays 4204 items. How can i refresh this data to display 815 items.
    how to solve this issue any ideas or suggestion????
    the reports is on ODS level.
    I hope  all of u take this problem as urs and try to give me solution as earliest possible.
    <b>this is high priority issue from client side</b>.
    thanks in advance . Surely il assign the points.
    email id: [email protected]
    Urs,
    Raki.

    Hey Lilly,
    Yep  i have deleted the contents of ODS sucessfully and i have reloaded it sucesfully but from biw side there is no problem as i feel.
    So i requested my onsite people to look in to the oracle db table how many records are available.Later then we will make take some decision .
    So still the problem isnot solved il be updating this in another couple of days.So i request u to take care this issue and now i have assigned u points also.
    Thanks for ur info.
    Possible give me ur personal mail id so that i can direclty drop to ur mail.
    Urs,
    Raki

  • Listing Items based on criteria e.g. High Priority Items First.

    Hi,
    One of our customers have a need to List High Priority Items first on the WebTools site.
    Let's take two ItemCodes for example: Printer001, and, Monitor001.
    >> If these two items are included in the same category then Monitor001 will appear before Printer001 as WebTools sorts in alphabetic ascending order;
    >> But, our customer wants Printer001 to appear before Monitor001 as it is an Item higher in priority that Printer001.
    I can think of two possible solutions:
    1/2) Prefix Items with a number or letter to have it appear first in the WebTools default sort order. E.g. Rename "Monitor001" as "AMonitor001". This will not be possible for existing Items in SAP, so it doen't solve the issue,
    Or,
    2/2) Customize the Default WebTools Item List block to sort Items based on a User Define field called "pririty". Which might require a lot of effort.
    Please advise if anyone else has solved similar issue and how.
    Thanks very much for your replies in advance.

    Hey Kafil ... I think you may be stuck modifying the parts list page or creating something from scratch. I'm not aware of an easy way to do this out of the box.

  • Is it possible in IOS to have two static routes for the same subnet, one a higher priority and "failover" between the 2?

    Hi All
    Is it possible in IOS to have for a particular subnet:
    a) Two static routes?
    b) Make one static route a higher priority than the other?
    c) If one static router "goes down", failover to the lower priority static route?
    We have a l2tp/vpdn connection to a supplier which can be accessed via two vlans/routes. I would like to make one route the preferred one but the "route" to failover if the preferred route goes down.
    Again, many thanks in advance for all responses!
    Thanks
    John

    Hi John,
    Hope the below explaination will help you...
    R1(config)# ip route 0.0.0.0 0.0.0.0 2.2.2.2
    R1(config)# ip route 0.0.0.0 0.0.0.0 3.3.3.3 10
    If you notice the Administrative Distance for the secondary route pointing to ISP2 is increased to 10 so that it becomes the backup link.
    The above configuration with just two floating static routes partially accomplishes our requirement as it will work only in the scenario where the routers interfaces connected to the WAN link are in up/down or down/down status. But in a lot of situations we see that even though the links remain up but we are not able to reach the gateway, this usually happens when the issue is at the ISP side.
    In such scenarios, IP SLAs becomes an engineer's best friend. With around six additional IOS commands we can have a more reliable automatic failover environment.
    Using IP SLA the Cisco IOS gets the ability to use Internet Control Message Protocol (ICMP) pings to identify when a WAN link goes down at the remote end and hence allows the initiation of a backup connection from an alternative port. The Reliable Static Routing Backup using Object Tracking feature can ensure reliable backup in the case of several catastrophic events, such as Internet circuit failure or peer device failure.
    IP SLA is configured to ping a target, such as a publicly routable IP address or a target inside the corporate network or your next-hop IP on the ISP's router. The pings are routed from the primary interface only. Following a sample configuration of IP SLA to generate icmp ping targeted at the ISP1s next-hop IP.
    R1(config)# ip sla 1
    R1(config)# icmp-echo 2.2.2.2 source-interface FastEthernet0/0
    R1(config)# timeout 1000
    R1(config)# threshold 2
    R1(config)# frequency 3
    R1(config)# ip sla schedule 1 life forever start-time now
    The above configuration defines and starts an IP SLA probe.
    The ICMP Echo probe sends an ICMP Echo packet to next-hop IP 2.2.2.2 every 3 seconds, as defined by the “frequency” parameter.
    Timeout sets the amount of time (in milliseconds) for which the Cisco IOS IP SLAs operation waits for a response from its request packet.
    Threshold sets the rising threshold that generates a reaction event and stores history information for the Cisco IOS IP SLAs operation.
    After defining the IP SLA operation our next step is to define an object that tracks the SLA probe. This can be accomplished by using the IOS Track Object as shown below:
    R1(config)# track 1 ip sla 1 reachability
    The above command will track the state of the IP SLA operation. If there are no ping responses from the next-hop IP the track will go down and it will come up when the ip sla operation starts receiving ping response.
    To verify the track status use the use the “show track” command as shown below:
    R1# show track
    Track 1
    IP SLA 1 reachability
    Reachability is Down
    1 change, last change 00:03:19
    Latest operation return code: Unknown
    The above output shows that the track status is down. Every IP SLAs operation maintains an operation return-code value. This return code is interpreted by the tracking process. The return code may return OK, OverThreshold, and several other return codes.
    Different operations may have different return-code values, so only values common to all operation types are used. The below table shows the track states as per the IP SLA return code.
    Tracking
    Return Code
    Track State
    Reachability
    OK or over threshold
    (all other return codes)
    Up
    Down
    The Last step in the IP SLA Reliable Static Route configuration is to add the “track” statement to the default routes pointing to the ISP routers as shown below:
    R1(config)# ip route 0.0.0.0 0.0.0.0 2.2.2.2 track 1
    R1(config)# ip route 0.0.0.0 0.0.0.0 3.3.3.3 10
    The track number keyword and argument combination specifies that the static route will be installed only if the state of the configured track object is up. Hence if the track status is down the secondary route will be used to forward all the traffic.
    Please rate the helpfull posts.
    Regards,
    Naidu.

  • How can I give the "user interface thread" higher priority?

    We do alot of activex calls to front panels. We need to increase/decrease the priority of the user interface thread to resolve our thread problem. Anyone know how to do this?
    Chuck

    Hello,
    As P.M. was saying, you can adjust the thread priorities
    through the VI Properties dialogue. 
    Another place to modify the multithreading system in LabVIEW is a VI
    located at: [LabVIEW Directory]\vi.lib\Utility\sysinfo.llb\threadconfig.vi.  However I do not think this will remedy any
    problems you are having.
    From a Multithreading in LabVIEW tutorial (http://zone.ni.com/devzone/conceptd.nsf/webmain/d2e196c7416f373a862568690074c759)
    Priorities in the User Interface and
    Single-Threaded Applications
    Within the User Interface execution
    system, priority levels are handled in the same way for single-threaded and
    multithreaded applications.
    In single-threaded applications and
    in the User Interface execution system of multithreaded applications, the
    execution system queue has multiple entry points. The execution system places
    higher priority VIs on the queue in front of lower priority VIs.
    If a high-priority task is running and the queue contains only lower priority
    tasks, the high-priority VI continues to run. For example, if the execution
    queue contains two VIs of each priority level, the time-critical VIs share execution time exclusively until both finish.
    Then, the high priority VIs share execution
    time exclusively until both finish, and so on. However, if the higher priority
    VIs call a function that waits, the execution system removes higher priority
    VIs from the queue until the wait or I/O completes, assigning other tasks
    (possibly with lower priority) to run. When the wait or I/O completes, the
    execution system reinserts the pending task on the queue in front of lower
    priority tasks. Refer to the Synchronous/Blocking Nodes section for a list of
    asynchronous functions that wait.
    Also, if a high priority VI calls a lower priority subVI,
    that subVI is raised to the same priority level as the caller for the duration
    of that call. Consequently, you do not need to modify the priority levels of
    the subVIs that a VI calls to raise the priority level of the subVI.
    Thus changing the priority of your VI will change the
    priority of UI calls for that particular VI. 
    Again, I caution you because I suspect that if you are having problems
    with your application not running correctly, I do not believe that manipulating
    the thread priorities will resolve these issues.
    Hope this helps,
    Travis M
    LabVIEW R&D
    National Instruments

  • Create at runtime a job to run at the central instance with high priority

    Hi All
    Using the function modules  (  job_open, job_submit and job_close )  or ( job_open, submit via job  jobname number jobcount, job_close) I need that this job runs in the central instance and with high priority.
    I would like to know how to  inform  it using the statements above?  How to pass the parameters to make the job run in the central instance with high priority?
    I would appreciate any help.
    Thanks in advance.
    João Gaia

    Hi
    I hadn't realized about the parameter TARGETSERVER of  the function module JOBCLOSE. I am going to make some tests.
    thanks in advance

  • Why is time-critical thread not interrupting sleepless high priority thread?

    Hello,
    I have two threads running in the same execution system on a real-time PXI platform. The time-critical thread sleeps using "AI Single Scan.VI", and acquires my data at a rate of 8000 Hz.
    I have a slower high priority process that calls a DLL function to calculate some filter coefficients. This function call takes longer than 1/8000 s to complete, and runs in a loop, executing as often as it can (with new data from FIFOs).
    I expected the time-critical thread to interrupt the the high priority thread without problem.
    I am finding that unless I insert a LabVIEW delay (for example a wait for x ms VI) in the loop, the real-time system stops responding. With a small delay (ie 1 ms), t
    he acquisition completes, and a FIFO shuts down the loop of the slow process.
    Why do I need a labVIEW delay in the high-priority loop, when the DLL function call itself is quite slow? Even without a DLL call, I would expect the time-critical VI to interrupt, finish its data acquisition, and shut-down the high-priority thread using its FIFO.
    Any suggestions?
    Thanks in advance,
    Frenk

    Here are a couple things to try/check:
    1) Check the call library node in your high priority VI. If it's orange (runs in UI thread), your high priority VI is actually switching to the UI thread every time your dll runs. That alone is not a problem. But if your TC VI tries to update any control terminals, the TC thread will switch over to the UI thread to access UI resources, possibly while the dll within your high priority VI has a lock on those resources. Why does the dll have a lock on UI resources? Because it was running in the UI thread and got interrupted by the TC thread before it finished doing its business. Not likely, but possible.
    2) There's another possible reason you're seeing this behavior. If the TC VI and the high VI call a mutual subVI, the subVI will be elevated to ALWAYS run in the highest priority thread irrespective of the actual caller (in your case, it's the the TC thread). Even when the *high priority VI* calls the mutual subVI, that subVI runs in the time-critical thread, which means there's a thread switch from high to TC, then back to high after the subVI finishes. And because high and TC VIs are in the same exec system, that mutual subVI will always run in the 1 and only TC thread alotted to that exec system.
    So, while your TC VI is running, you're in the TC thread. While, your high VI is running, you're in a high non-TC thread, and when your high VI calls the mutual subVI, you're again in the TC thread until the subVI finishes.
    So how could this arrangement cause your TC VI to become starved by the high VI? If your TC VI wakes up while the high VI is in the middle of running the mutual subVI, the TC thread responsible for running the TC VI is actually busy (in the middle of running the subVI in your high VI!!!), so the TC thread cannot run your TC VI until it finishes running that mutual subVI.
    The fix: make your TC VI run in a different exec system. It will be given its own TC thread that no one else can mess with. When TC VI wakes up, it's guaranteed a TC thread.
    I think there's a good reason behind why a mutual subVI ALWAYs runs at the highest priority of all its callers, irrespective of the actual caller's priority...but I can't think of the reason at the moment.

  • EIM Auto pushback - requeue at higher priority?

    Hello,
    In our EIM 4.3.2(8) implementation (ICM Enterprise integrated queues and agents), all new and incomplete activites auto-pushback to queue after 8 hours (overnight generally). The problem with this is, they're getting pushed to the back of the queue. I'd like to have all auto-pushback emails queue at a higher priority so that during days of high email volume, we don't get stragglers that keep getting pushed to the end of the queue while newer emails get handled.
    I saw this:
    http://docwiki.cisco.com/wiki/Transferred_Emails_Get_Sent_To_End_of_Queue
    and thought maybe I could pull some Activity related column through to ICM to act on to change the priority... Not sure what I should use though. I considered looking at the "WHEN_CREATED" field and upping the priority in ICM if that's more than a day ago, but I wonder if there is a simpler way to do this.
    Any help you can provide would be greatly appreciated.

    New tasks are sent from EIM to ICM in order queue priority, activity priority and oldest - in that order. While sending new task there is no differentiation between new email first time in queue Vs email which is auto pushed back to queue, if queue and activity priority are same then oldest activity criteria will be honored.
    There is no other way in default EIM product to push auto pushed back emails ahead of others.

  • High Watermark issue with monitoring Service Manager 2012 R2

    Hi,
    Our customer has a Service Manager / Operations Manager 2012 R2 environment where SCOM will regularly generate an alarm related to High Watermark monitoring on the Service Manager data warehouse - not every day though. The alarm looks like this:
    Value of 3559 is not higher than 3559
    This value hasn't changed for weeks.
    Having done a lot of searching we have found nothing but reference to the same recurring flow of information where people keep mentioning different values but there is no conclusion of what this might be caused by and how to solve it. The solutions
    have become outdated anyway. Here is one example:
    http://social.technet.microsoft.com/forums/systemcenter/en-US/889af8f3-cdf8-4d88-ae99-5dbe18d529ef/service-manager-2012-data-warehouse-high-watermark-monitor
    The Service Manager Database Account in SCOM is our service account that has sysadmin in SQL. Basically, with regards to the security configuration, our customer should be covered.
    To my knowledge agent-based and agentless monitoring have both been supported since SCSM 2012 SP1. Also, we have the latest management pack for Service Manager monitoring in SCOM, at the moment this should be
    7.5.3079.0.
    As mentioned above the value has not been changing for quite some time and nor has it in the database.
    My questions are the following:
    - Is there anyone that has found a solution in the meantime, especially with regards to R2?
    - What is the purpose of High Watermark monitoring for the data warehouse? Why does this need to be monitored?
    - We would like to understand the nature of this value better. Should it be higher each day compared to the day before?
    - Could it just be overriden in SCOM?
    Many thanks in advance!

    Rather unexpectedly, the SCOM alarm disappeared overnight and when checking the workflow in the incident that was generated from the alarm, the incident got a Resolved status right before midnight at 23:59:58. We have a ConfigMgr connector that is scheduled
    to run at 23:00 which we had disabled a day ago to check something else. But I don't think it had anything to do with this. As the alarm has disappeared from the SCOM console, we have also checked the registry values. Now, instead of "3559 3559 3559"
    it says "3559 3559 3585". We have had the 3559 value since 18th July, and out of a sudden something must have been triggered, causing the value to increase. What was triggered and how, no idea... Not sure either what it means that only one of the
    Three numbers have been updated with a new value. When talking about the DW jobs, using the SMlets we can see every day that, MPSync, DWMaintenance and the ETL jobs are working well. What we have had though for a longer time is that the cube processing
    tends to have issues once a week, where processing won't finish and the cubes get hanging in a running state. We can fix that manually every time and often we don't even have to touch DWMaintenance or the ETL jobs, we don't need to go beyond manually
    working with the cube processing jobs themselves. So it might not have an impact on the ETL jobs themselves. Occasionally we do find ourselves in a situation where we we need to play around in the SQL database and manually set the required value (can't
    recall if it's 3, 6 or 7) cause we get an error in the DWMaintenance batch, but even though that's an occasional issue it's not constant and also something we can solve, and furthermore it's another known issue outside of the high watermark issue. So
    we are a bit uncertain but can at least see that something works sometimes that sometimes increases the high watermark value :). In our case.

  • Can I make "High Priority" default - or is there a script?

    Hi,
    When sending an email, is there a way to choose to mark the message as "High Priority" without having to go up the the "Message" menu to do so? If there isn't a keyboard shortcut, is there a script out there anywhere that can do that?
    Patrick

    not important to me any more

  • The technical name of 5GHz has high priority in dual band AP

    Hi,
    As I know, when open dual radio on some Cisco's AP, and configure one dual wireless client associate with the AP, the AP will use 5GHz for wireless client to associate first.
    Does somebody know this technical or function name?
    I'm looking for the AP which has this kind of function.
    Thanks.
    Walter

    Hi Eric Moyers,
    Thanks for your reply.
    Sorry about describe not clearly.
    For example:
    1. Enable 2.4G and 5G on an AP, and configure both SSID on these 2 band with the same SSID "ciscosb" and security "WPA2-AES".
    2. Configure a dual band wireless card to associate with an SSID "ciscosb". (specify the SSID in the profile)
    3. AP will be associated via 5G band. 
    So 5G can has high priority to be used. Is this new design? or base on chip?
    I have used WAP561 to perform the steps, but WAP561 was associated via 5G or 2.4G randomly.

  • TO priority fields to high priority for  special kind of materials.

    Hi,
    Can we automatically set the TO priority fields to high priority for Can we automatically set the TO priority fields to high priority for special kind of materials?
    thanks
    Raj Kiran

    Hi Prashant,
    Is there any way the TO priority can be set to high priority before at the time of TO creation. Becuase the operator has to go through each TO to see if it is a special material which need special attention.
    Can we automate this process a little bit by assigning a high priority to TO(automatically) for these kind of materials or is there any other alternative possible through "Special movement indicators"?

  • Workflow: Setting the high priority flag

    Hi,
    Does any one know how to set the priority for the email notification?
    (Eg: In microsoft outlook red exclamatory mark for high priority)
    I tried the option priority in notification and message but its not giving the desired output(i.e Flag).

    I know you can set the priority on the task.
    If you click on the User step and go under Routes and Priority, you can change the priority and you will see a different icon in Workspace.
    I'm not sure this will change the priority on the email though.
    Jasmin

  • Query:Pop up on login for incomplete high priority tasks in sap inbox

    Hi All,
    I am having requirement to display pop up for incomplete high priority in sap inbox on loging in sap.
    I wil be thankful if you can guide to fulfill this requirement.
    Thanks.

    Hi,
    To get the High priority work items you can use the table SWWWIHEAD.
    using this table you can get the Priority, Status, and agent of the work item. Using this you can build the logic to
    display the pop up with this details.
    Thanks,
    Viji.

Maybe you are looking for

  • Why does my slingbox no longer work on my firefox?

    my slingbox no longer works, even though the slingbox site says it works with firefox 4 or above.

  • My hp office jet 6600 keeps saying the pinhead is missing

    I installed new print cartridges but cannot get my HP Office 6600 wireless printer to print.  It keeps saying the pinhead is missing.  I have turned the printer on and off several times.  The show me button does not work.  Please help me!  What shoul

  • Stock transfer between 2 projects of different plants.

    Hi All, We have two plants and each plant as multiple projects. Some time it is required to transfer stock between two project which are of different plants. Currently we are using MOVEMENT TYPE 415Q , where stock transfer is done using 4 steps. Our

  • Cisco ISE 1.2 and 2 Active Directory Domains

    Hi Support, does anyone know whether I can perform Certificate Authentication for two different Active Directory domains using the same ISE host / deployment? We have two forests with a trust link between them. We have a seperate PKI in each domain.

  • Failure using {CALL } syntax & passing string params w/ # (hash)

    We are experiencing a problem calling functions using the {CALL } syntax and passing string parameters that contain # (hash) symbols. Apparently, something interprets the # inside the string literal and fails the call. We use this syntax with procedu