Hai,
     I am using cRIO 9104 with NI 9421(DI SINKING) module for my counter application in scan mode.
I have a doubt that how do i reset my counter previous value when my system is in idle mode(i.e stable mode).I tried to use a timeout in property node, But i am not able to put a timeout in my code ,herewith I have attached the printscreen of my program.You can see the timeout option is in hide mode.Any other option is there to reset a counter.Kindly solve this problem and let me know the details.
Thanks and Regards
Jayanthi.K
Attachments:
Untitled.png ‏292 KB

You need to get a refnum for the module.  The simplest way to do this is to drag the module in the project onto your block diagram.  It will drop a refnum constant for the module.  You will find all kinds of useful properties and methods on this refnum.  In this case the refnum is of a class named "SD Module" (where "SD" stands for "Specialty Digital") and it has a method on it for resetting counters.  See the attached screenshot of the block diagram.
Ross Houston
Senior Software Engineer
RIO Software R&D
Attachments:
reset_counter.png ‏3 KB

Similar Messages

  • How do i reset play count?

    How do i reset the play count on my iPod? (I have an iPod Video.) Also, in anyone knows how to do it on itunes too, that would be awesome. Thanks.

    In iTunes go to edit/select all (or highlight just the songs that you want to reset). Right click on the songs and select "reset play count". Click 'ok'.
    Sync your ipod to iTunes to reflect the changes on there also.

  • How do you reset an ipod tough 4g in disabled mode

    my ipod is disabled and i forgot my password

    Place the iOS device in Recovery Mode and then connect to your computer and restore via iTunes. The iPod will be erased.
    iOS: Wrong passcode results in red disabled screen                          
    If recovery mode does not work try DFU mode.                         
    How to put iPod touch / iPhone into DFU mode « Karthik's scribblings         
    For how to restore:
    iTunes: Restoring iOS software
    To restore from backup see:
    iOS: How to back up
    If you restore from iCloud backup the apps will be automatically downloaded. If you restore from iTunes backup the apps and music have to be in the iTunes library since synced media like apps and music are not included in the backup of the iOS device that iTunes makes.
    You can redownload iTunes purchases by:
    Downloading past purchases from the App Store, iBookstore, and iTunes Store

  • How do I reset an STC Counter using DAQmx?

    When another digital line goes high I want to reset my counter. How do I reset the counter using DAQmx?

    Hello,
    Thank you for contacting National Instruments.
    Please see this link for information on this issue.
    I have attached an example program which shows how to to do this in software.
    Regards,
    Bill B
    Applications Engineer
    National Instruments
    Attachments:
    Count_Digital_Events_with_Reset_Button.vi ‏68 KB

  • How do i reset the play counter

    My i-tunes says I've played some of my songs over 46 million times. I'd like to use my top 25 most played playlist so is there any way i can reset the counter on specific songs? if not, how do i reset the counter for my entire library?

    Control click -> Reset Playcount

  • NI-6602 - Encoder capture - resetting the counter to 0 through software - DAQmx

    Hello. A simple one. I'm using DAQmx to set up a task to set channel 0 on an NI-6602 as an angular encoder capture port. This is working fine and I can grab the position in degrees. The simple question is - How do I reset the counter to 0 through software. I can set up ZIndex to do it but how do I either reset the counter or set it with an arbritrary number? I can see a method to set it on startup but not during capture.
    Thanks.
    Will

    If working in LabVIEW, there are DAQmx property nodes that will allow you to set the "initial count" value, but ONLY while the task is stopped.
    If you can't count on a hardware z-index reset, another software technique I've used to avoid stopping the DAQmx task.  I make a wrapper function for all my encoder task access (see the Action Engine nugget for ideas...).   Inside this "Action Engine" wrapper, I use an uninitialized shift register to store my encoder's "virtual 0".  I add a simple function to the action engine for setting the "virtual 0" to be the current encoder position value.  Every time I read from the encoder, I first subtract off the virtual zero before returning the data.  As far ast the rest of the app is concerned, the encoder data it gets is just as if I were able to make a software call to DAQmx to set the raw count to zero.
    -Kevin P.

  • My ipod touch is stuck on the restore picture and when i try and sync it to itunes i cant sync to itunes because i have a password on my ipod touch and i cant get to the main screen so how do i reset my ipod ?

    my ipod touch is stuck on the restore picture and when i try and sync it to itunes i cant sync to itunes because i have a password on my ipod touch and i cant get to the main screen so how do i reset my ipod ?

    Connecting in recovery mode will help: http://support.apple.com/kb/HT1808

  • My Ipad mini displays disabled. I tried to restore on itunes but gives me error code how do I reset .

    My Ipad mini displays the message disabled. I tried to reset on itunes but no luck. It gives me an error message that ipad has been locked with passcode. Tells me to enter the passcode I dont remember it. How can I reset without passcode.

    Force iPad into Recovery Mode (Step by Step)
    1. Hold Sleep/Wake button down and slide to turn off iPad
    2. Turn on computer and launch iTune (make sure you have the latest version of iTune)
    3. Plug USB cable into computer's USB port
    4. Hold Home button down and plug the other end of cable into docking port. Do not release button until you see picture of iTune and plug.
    5. Release Home button.
    On Computer
    6. iTune has detected iPad in recovery mode. You must restore this iPad before it can be used with iTune.
    7. Select "Restore iPad"...

  • How can I get record count with a query?

    In Client/Server pplication,the client send a query to server.
    How can server get record count by oracle call interface?
    Is it need execute "select count(*) from ...."?

    Yes.
    Either that or increment a counter for each record fetched and
    loop round until you hit the last record.
    The first method would be more efficient on large datasets.

  • Private Mode - I forgot my unlock Pattern, how can I reset it?

    I set up Private Mode when I first got the Note 4.
    Now I forgot my pattern to unlock private mode.  How can I reset it so I can use private mode again?

        bappelman, I am sorry to hear that this is going on. Unfortunately when a passcode is unknown you would have to reset the device to factory defaults in order to reset the password/pin. Take a look here to see how http://www.verizonwireless.com/support/knowledge-base-104013/.
    AdamG_VZW
    Follow us on Twitter @VZWSupport

  • HT201210 I've forgotten my passcode. How do I reset?

    I've forgotten my passcode. How do I reset?

    Place the iPod into recovery mode and then restore it as a new device.
    See here:
    http://support.apple.com/kb/HT1808

  • Resetting the Admin password in single user mode

    Ok, my friend bought an old Imac from someone she went to school with with OS 10.4.2 on it. It works fine except that she can not install any programs because there is an admin password that she does not know. She asked the person she bought it from, he says he doesn't even remember setting a password. Normaly with this issue id just pop in the install disk and reset it from there, except neither of them have the install disk, and my install disk is to current for the machine. Does anyone know how I can reset the admin acount using single user mode commands? I can do it on my Mac Book pro but it doesn't seem to work the same way on 10.4. Please help!
    EDIT: It is a Power PC G3 if that helps.
    Message was edited by: CartooNxHerO

    CartooNxHerO wrote:
    Ok, so I used the advice from the third link you gave me but i'm still in single user mode trying to figure out how to delete the users home folders.
    Message was edited by: CartooNxHerO
    You do not need to delete "the users home folders". Nor do you need to delete the netinfo database. Here are two proceedures:
    Change Password
    Mac OS X:
    Changing or resetting an account password via GUI:
    Resetting a user's password
    Resetting the original administrator account password
    http://docs.info.apple.com/article.html?artnum=106156
    You do not have a CD/DVD
    Changing password from single user mode:
    You can also change the administrator's password from single user mode or create a new administrator account.
    You need to get into single use mode for steps one and two that are listed below.
    This page will tell you how to get into single user mode.
    http://support.apple.com/kb/HT1492
    Basically, you hold down the command-s key then powering on your machine. The command key has a little apple symbol on the lower left. It is between the alt/option key and the space bar. On a PC keyboard, it will be the windows key, I think.
    1) You can change the password on an account. ( Do you know Unix. You are in a Unix single user console. ) The setup commands you need should be listed on the screen. For Mac OS 10.4.11, the commands are:
    # Type the follow two instructions to access the startup disk in read/write:
    /sbin/fsck -fy
    /sbin/mount -uw /
    # Start up some utility processes that are needed.
    sh /etc/rc
    # You will probably need to press the return key once the system stops typing.
    # To find out the users on the system type, use the list command. The l is a lower case L:
    ls /Users
    # One of these accounts will be the administrator.
    # Pick one of the users which I'll call a-user-name and type it in this command:
    passwd a-user-name
    # and enter the new user password. You need six characters.
    # You will need to enter your password twice. Your typing will not show up on the screen just
    # press enter when you complete the typing.
    # For cryptic information on these commands try:
    man ls
    man passwd
    The root account isn't enabled by default. I am not sure if changing the password on root will enable it.
    2) Get the Mac to set up an additional administrative account. You can then change the password on your old account.
    Start with your computer power off. Hold down command-s. Power on your computer.
    Type in the following:
    The first two commands will depend on your release of Mac OS X. Look at what is typed out in the console to determine the exact format.
    # Type the follow two instructions to access the startup disk in read/write. Press return after each command.
    /sbin/fsck -fy
    /sbin/mount -uw /
    cd /var/db
    pwd
    #List all files. The l is a lower case L.
    ls -a
    #The move command acts as a rename command in this format.
    mv -i .applesetupdone .applesetupdone.old
    reboot
    Once you've done that the computer reboots and it's like the first time you used the machine. Your old accounts are all safe. From there you just change all other account passwords in the account preferences!!
    Limnos adds detailed explainations:
    http://discussions.apple.com/message.jspa?messageID=8441597#8441597
    The above the idea came from a post by JoseAranda at September 9, 2006 3:48 AM
    http://www.askdavetaylor.com/howdo_i_reset_my_mac_os_x_admin_rootpassword.html
    You will need to scroll down to see this post. Search for applesetupdone
    Or see:
    http://superpixel.ch/articles/running-setup-assistant-again/
    Once you have a new administrative account, you can change the password of your old administrative account
    blue apple > System Preferences > Accounts

  • How to reset a count variable in a conditional format trigger

    I am using a conditional format trigger to eliminate sections of a report where there is no data. The trigger is automatically generated by reports (shown below). the condition is :com_count = '0' therefore no record, no display of section - if :com_count>0 then data present and display record.
    It works fine eliminating the sections - until actual data is found - and count is set to 1 and it displays the record. The problem is that once :com_count >0, then the section displays throughout the rest of the report whether there is actually data or not.
    It seems that :com_count needs to be reset to 0, but when I try to do that, it throws an error stating that :com_count is a read only variable.
    I am new to PL/SQL so can anyone suggest how I can reset the :com_count to 0 each time the trigger fires with :com_count = 1?
    Any help would be appreciated. Thanks,
    Glenn
    The conditional format trigger is:
    function M_G_COM_RANK_GRPFRFormatTrigge return boolean is
    begin
    -- Automatically Generated from Report Builder.
    if (:COM_COUNT = '0')
    then
    return (FALSE);
    end if;
    return (TRUE);
    end;
    The count
    It works perfectly

    wher is your COM_COUNT defined?
    If should be defined in the datamodel in the "mastergroup" of the "detailgroup" of which you want to count the records.
    If you do so, there is a property of the item "Reset at" ( which is by default set to "Report") and you then can change it to the name of the mastergroup. So every time a new record is "active" in the mstergroup, the count-item will be reset to 0.
    hope this helps

  • How to reset a counter on external signal in LabView?

    Hallo there!
    I am using LabView v 8.5 and the NI USB-6211 to acquire signals, among them are the following:
    1) angular pulses from a rotary encoder
    2) a reference pulse for the rotary encoder witch will give a pulse on a specific position of the movement for every rotation
    3) value from a pressure sensor
    What I am trying to do is to create a pressure/volume diagram based on the pressure and volume inside a cylinder of an IC engine. To do this, I will need the angle of the engines crankshaft to calculate the pistons position in the cylinder. This way I can calculate the volume and put it in a xy graph to represent the volume (x-axis) and the pressure(y-axis).
    I am using clk0 to count the pulses from the angular encoder, and this works great. However I now need the reference pulse to somehow reset the count at the precise time it goes high in order to precisely know the angular position.
    How can I do this? And how precise will this be? And will I need any kind of synchronization with my pressure measurements? If so, how?
    The relevant part of the program I am working on resembles the Count Digital Events with reset.vi 33 KB as found in this thread. However, I don't know how to get the reference pulse to reset as the stop button is. How can I do this?
    In addition: the fast pulses of the angular encoder = 0-> ~10kHz. I seem to lose information if I use the basic level trigger detection.vi when I put this signal on an analog port.
    -J

    Hi Nick,
    If you have an X Series or 2nd Generation cDAQ chassis (basically any cDAQ chassis except for the 9172 or 916x sleeves) then you can implement:
    1,2,3,4,5,6,7,8,9,10,(reset),1,2,3,4,5,6,7,8,9,10,(reset),1,2...
    You would have to configure an Edge Count Task, set the initial value to 232 - 6 (such that the 6th count causes the counter to rollover, which generates a pulse on the counter output), and enable the count reset using your external signal:
    The count reset isn't currently available for other DAQ devices, but I believe it should be available on M Series (62xx) and TIO (660x, 6624) with a future driver release (some time in 2012).
    If you don't have an X Series (or gen II cDAQ), don't despair.  On other hardware, you can get close to the previous behavior with a counter output task, with the exception that the "reset" signal would only be detected after the 2nd tick after your pulse is output.  Also, the reset signal would have to occur at the beginning to arm the counter the first time.
    Or, you can get the 3rd behavior that you asked for by doing a continuous counter output task with the external signal as the source of the timebase ticks.  For example:
    1,2,3,4,5,6,7,8,9,1,2,3,4,5,6,7,8,9
    In toggle mode (default):
    6 ticks of initial delay, 2 ticks high, 7 ticks low, 2 ticks high, 7 ticks low, ... etc.
    In pulse mode:
    6 ticks of initial delay, 9 ticks high, 9 ticks low, 9 ticks high, 9 ticks low, ... etc.
    See here for an overview of the difference of the two modes.  Basically, pulse mode will emit a short pulse when TC is reached, and toggle mode will toggle the state of the counter.  You can't have less than 2 ticks as a high time, low time, or initial delay.
    Best Regards,
    John Passiak

  • How to reset play count

    how to reset play count in iTunes

    Right-click the track(s) in iTunes, and choose "Reset Plays."

Maybe you are looking for