How to disable daqmx base autorun in wince 6.0

when i am connecting mini 2440 to pc through active sync automatically daqmx base is running and arm2240 is getting hanged.

Definitely you need a USB client driver. Again what client class driver is required is depend on the USB touch screen module. Some vendors have a touch screen consist of one touch screen controller and a USB serial controller chip, the touch screen is exposed
as a USB serial client device though this you will read/configure the touch controller. In this case you need a USB serial driver to access this as a serial port and on the top you have to develop a touch driver as shown on the above link. It is all vendor
specific. Normally you need a bus to  interface the touch controller. some touch screen controller are interface with I2C or SPI. Similarly here the bus is USB for your touch screen. So you need both driver, one is bus driver to access the touch controller
and another driver is to implement the touch functionality as shown in the above link.
First of all find the USB client class for your touch screen driver. you can contact  the vendor or read the datasheet given by them.
Please mark as answer, if it is correct.
Please vote,if it is helpful post.
Vinoth.R
http://vinoth-vinothblog.blogspot.com
http://www.e-consystems.com/windowsce.asp

Similar Messages

  • EAM OSP: How to Disable Requisition Import AutoRun on Work Order Release?

    Hi,
    We want to create Purchase Requisition for OSP resource Items from eAM Work Orders by manually running Requisition Import request from purchasing. But as work order is released Import Requisition is auto run and requisition created. Is there any parameter or profile option to stop this request from auto run on release? Kindly guide.
    Regards,
    Syed Mustafa Arshad   

    Hi Hrishi,
    Thank your for your response.
    The second option you specified Operation is used in case of Oracle Discrete Manufacturing not for EAM. It is used when you want to start requisition as Item is moved from one operation to next so it cannot be used in case of EAM.
    We wanted it because our requirement was to generate requisition in incomplete status and with requisition import automatically parameter is passed as "Yes" for Workflow and requisition is generated in Approved Status. There is a patch but it was not working fine with 12.1.3 and the issue is on SR and we needed a work around urgently. But now a new patch was provided and it seems our issue is resolved now and now Workflow parameter is passed as "No".
    And about requisition creation time, I came to know after raising service request that it is standard functionality and requisition import cannot be delayed to run it later manually.
    Thank again for your response.
    Best Regards,
    Syed Mustafa Arshad

  • How can I programmatically install support for DAQmx Base to a PDA?

    Greetings, I am developing a LabVIEW application for a PDA (HP iPAQ in this case), and a companion VI that will run on a PC. One of the things I need to do from this companion VI is provide a means of programmatically rebuilding the PDA application, including reinstalling support for DAQmx Base. I think I know how to rebuild the LabVIEW application using the Project, but I don't see how to install DAQmx Base. What is the best way to do this?
    Thanks in advance!

    How would you programatically rebuild the PDA application? If you are interested in reinstalling the DAQmx Base driver on the device, then you will need to navigate to Start»Programs»National Instruments»NI-DAQmx Base»Utilities and launch the driver installation utility that corresponds to your device. If you are interested in doing this programatically, you could run the executable from C:\Program Files\National Instruments\NI-DAQmx Base\Pocket PC using the System Exec.vi. I don't think there is any other way of doing this.
    Adnan Zafar
    Certified LabVIEW Architect
    Coleman Technologies

  • How to count number of NI digitizers installed [NI-DAQmx Base]

    I'm the author of a cross-platform scientific data acquisition/analysis program (C++ using Qt: Windows and OS X). I'm just getting started on adding support for NI digitizers. It's tougher than I was expecting - there's so few helpful code examples. On Mac OS X I'm stuck with NI-DAQmx Base. I'd be very grateful if someone could help me with a couple of basic questions...
    1) How do you determine if the computer has an NI digitizer installed?
    1a) Is there a way to count the number installed?
    2) How do you synchronize things so that the input and output streams start at the same sample point?
    Thanks,
    John.
    Dr John Clements
    Lead Programmer
    AxoGraph Scientific

    Hi John,
    DAQmx base does not have property nodes, therefore we cannot
    programmatically determine information about the cards. We typically refer to
    our high-speed scopes (51xx series) as digitzers, in which case, there are no
    drivers for MAC. Our other DAQ cards, E-Series (60xx) and M-Series (62xx) work
    with DAQmx base according to the readme.
    If you are using a DAQ card, I would like a bit more clarification about question 2. When you say start at the same sample point, do you mean start simultaneously so that the input and output start at the exact same point in time? If so, I may suggest triggering them both off of the same digital line.
    David L.
    Systems Engineering
    National Instruments

  • How to recognize s-series daq card in DAQmx Base 2.0

    I installed the "DAQmx BASE 2.0", and then installed 3 PCI DAQ boards.  It can recognize PCI-6024E and PCI-6713, but not PCI-6133.
    I followed exactly the same procedure as in the document called "How do I use NI-DAQmx Base with PCI/PXI Devices on Windows?"
    http://digital.ni.com/public.nsf/websearch/9C4E9FD0C7469BC286256F100074EADC?OpenDocument
    However, there is a web page (the link below) having labview example programs using DAQmx Base for "NI 6110 S Series Multifunction DAQ". So I think probably there is a way to recognize the S-series devices in DAQmx base.
    http://digital.ni.com/public.nsf/allkb/722DDAB4E914073D8625708100773677
    Does anybody know how to recognize S-series device in DAQmx Base 2.0?
    Thanks

    Alan,
    Thank you very much for the quick response.
    The reason I explored DAQmx: I want to do RLP and DAQmx Base has a simpler interface and more examples for RLP.
    The reason I want to go RLP instead of DAQmx is a long story.
    Summary of my applications:
    I need to read 4 input voltage (using PCI-6133) and then generate 12 voltages (using two PCI-6713 each has 8 outputs). Since the 12 generated voltages are related to the 4 input voltages, single sample /N channel AD/DA is required. The speed for the overall control loop has to be >100 kHz.
    Summary of my configurations:
    PIII, 700 MHz CPU, 512 MB RAM
    PCI-6133 and PCI 6713, LabVIEW 7.0, and DAQmx 8.0
    I also have PCI-6110 and PCI-6024E cards for comparison
    Summary for 4 channel single point acquisition (See the table below, AD only)
    1) The difference between P3/700MHz computer and P4/3GHz computer is very small
    2) The S-series performed worse than E- and M- Series
         Spec (kS/s)   Tested by me(700MHz P3)   by NI engineer (3GHz P4)
    6024E   200/4            15.7 kHz                    17.36 kHz
    6040E   250/4                                        18.9 kHz
    6251   1000/4                                        23.0 kHz
    6133   2500/1            13.8 kHz
    Summary for single channel single point acquisition (See the table below, AD only)
    1) The S-series performed much worse than E- and M- Series (simultaneous sampling is worse?)
         Spec (kS/s)    Tested by me (700MHz P3)
    6024E    200/1           54.8 kHz
    6110    5000/1           19.4 kHz
    6133    2500/1           14.5 kHz
    Simulated device          135 kHz
    Summary for single channel single point AO (See the table below, DA only)
    The spec of 6024E is only 10kS/s, but the loop can run at 132 kHz (the output from the port was not correct for sure). Using a simulated device (either 6024E or 6713), the loop rate is ~ 134 kHz (probably due to my low speed computer). This means the latency from 6024E devices is virtually zero. However, the latency from 6713 is way too much.
          Spec (kS/s)   tested by me (700MHz P3)
    6024E    10/1             132 kHz
    6713   1000/1              38 kHz
    Simulated device          134 kHz
    From all the above tests, it seems that s-series device (6133) and AO device (6713) perform much poorly in single point mode compared to E-series device (6024E).  I thought the difference might be due to the driver in DAQmx.  So, I want to try RLP to see whether I can gain up control loop speed to 100 kHz for my applications.
    Your suggestions and advices are appreciated.
    Thanks
    Jin-Xing

  • How to disable autorun for usb ?

    hi,
    any body please tell me how to disable auto run for usb as we connect it.

    Hi,
    I am writing to add a note to help anyone trying to do this.
    I had been searching for help on this for hours and the Microsoft KB you referenced only gets you part way to the solution.
    The problem on my T60 was the Group Policy Editor /Admin Templates did not show the System so I  could not get to the "Turn off Autorun" item as referenced in the KB. I could not find the soulution anywhere on Microsoft or other help forums.
    Good News!  Here on the T400 forum this question was answered in 2008. The solution works great. My thanks to the contributor of the answer. Here is the text of the answer: I guess it would apply to any Thinkpad and others as well.
    Posts: 1
    Registered: 12-20-2008
    Location: California
    0
    Re: gpedit - many functions missing, please help
    Options 
    12-20-2008 12:58 AM
    Hi tdushane,
     I had this same issue on my XP SP3 machine. This is how I resolved the issue:
    1. Go to start run and type in gpedit.msc
    2. Under computer configuration right click on the administrative templates
    3. Click on add/remove templates
    4. Click the add button
    5. In the folder look for system.adm and double click on it
    6. Verify that system is listed then click close.
    Now you will see all the missing folders.
    Hope this helps!
    ~JB~
    This helped me too

  • USB-6009 Daqmx Base 3.3 Cannot creat 2 or more channels on Windows mobile 6

    Hello,
    I have USB-6009, PDA iPAQ 214, WM6, Daqmx base 3.3, Labview 2009. In order to create new mobile project I use wizard and standart dynamic example: Cont Acq&Graph Voltage-Int Clk.vi. All works ok, but if I add more chanels in VI "Create Channels" or place new VI block and enter "Dev1/ai1", exe on my PDA cannot work correctly. Exception after RUN. I have no idea how build correct application with 3 channels without this exeption...  On PC all works. Whay right way to create channels? I attach VI which don't work, for examle. I read daqmxbase cannot support WM6, but 1 channel work ideal!
    Attachments:
    diagramm.jpg ‏113 KB

    Vital000,
    I forgot to mention that, yes, Windows Mobile 6 is not supported along side of DAQmx Base. That means you might be able to get some  of the same functionality(limited) that you would with Windows Mobile 5, but most likely not 100% functionality. This could explain why 1 channel works and multiple channels do not. I will try and help you out, but as this is not supported my ability to help is limited.
    Ben Sisney
    FlexRIO V&V Engineer
    National Instruments

  • NI-DAQmx Base - "Read or Write task without first setting line states"

    I am writing an application to interface with the USB-6501 hardware platform. In my application, I am first initializing all the lines on each digital port to be either read or write lines. After these lines have been initialized to the correct state, I would like to write data to a specific port, or read data from that port, without having to again define the line states (i.e. I'd like to write data to the port based on the already configured lines).
    Here's how I approach the problem. On initialization, my program will create a DAQmxBase task which will set the lines I specify as "Write" lines for port0, following this is another task which specifically sets the "Read" lines for port0. When I create a task to simply read or write data to a port (without again defining which lines are write and which lines are read) I receive the error "-200428 - Value passed to the Task/Channels In control is invalid.". If I define the read and write lines as a step in the same task which reads or writes data (respectively), the process seems to work ok.
    Can anybody offer any insight to whether or not I should be able to accomplish this task using this approach?
    Thank you for your help.

    Hello DarkCloud. Thank you for contacting National Instruments. If you create a task in the DAQmx Base Configuration Utility and set the direction of the line, you don't need to reset the direction in LabVIEW. There are some examples of how to do this at Start>>All Programs>>National Instruments>>NI-DAQmx Base>>Examples>>LabVIEW 7.1. Open the static example for DIO>>Write Dig Port. Please let me know if you have any questions. Have a great day!
    Marni S.
    National Instruments

  • NI-DAQmx Base 2.0 and Win Mobile 5

    Hi,
    Can anybody tell me if NI-DAQmx Base 2.0 is compatable with Win Mobile 5 devices?
    I'm trying to capture analogue voltages and my app builds fine and loads to the PDA, but the PDA is not seeing the PCMCIA DAQ card (6062E) that I'm using.
    I have run the "Base" installer which has copied the Base driver file/s to the PDA (and I have the Base task setup OK in the VI), but the PDA comes up with an "Unrecognized Card" error. I have removed the Base driver/s from the PDA and reinstalled them but with no luck.
    Is this just because Base 2.0 is not compatable with Win Mobile 5?
    Is there any way I can get Base 2.1 to work with LV-Pro-8 and PDA-8 or is there some other way I can get the drivers onto the PDA that will handle the 6062 card under Win Mobile 5.
    Any help would be greatly appreciated,
    Thanks,
    Paul.
    Solved!
    Go to Solution.

    Hi Paul,
    Good afternoon and I hope your well. 
    One thing to bear-in-mind is that DAQmx Base doesn't offically support Windows Moble 6 devices - even though they have been seen to work. This is not to get confused with LabVIEW 8.6 which does support Windows Mobile 6. i.e. just not DAQ applications/DAQ hardware. 
    I am another customer, here at NI UK Support and I have another customer with the an issue with WM6 and DAQ CF, I'd like to work more with you on this.. could you please provide more details on how it goes tomorrow and the tests you do. 
    For reference please look at these links: 
    http://zone.ni.com/devzone/cda/tut/p/id/7705#toc0
    http://digital.ni.com/public.nsf/allkb/F6576C46AD7B42768625758200510715?OpenDocument
    Thanks
    Kind Regards
    James Hillman
    Applications Engineer 2008 to 2009 National Instruments UK & Ireland
    Loughborough University UK - 2006 to 2011
    Remember Kudos those who help!

  • How to disable iMessage for a specific contact/How to unregister iMessage from former device

    I switched from an iPhone 4 to a Galaxy S3. When my wife who still has an iPhone 4 tries to text me it still sends the message as an iMessage and I NEVER receive the text on my Galaxy S3. It still shows the little blue bubble next to my name when starting a new text thread. So I checked with about 4 other iPhone users that text me on a regular basis and I'm not receiving any of their messages either.
    If the iPhone users turn off iMessage the text comes right through. However I dont expect all the iPhone users on my contact list to turn off the iMessage feature just so they can text me.
    I no longer have my old iPhone. I traded it in at Best Buy so there's no way of going back in the phone to change any settings. The iPhone was wiped of all data and settings anyway before I traded it in.
    I took my wifes iPhone and deleted my contact. Then I added it back. Still shows my name as iMessage. I took my e-mail address out of my contact entry on her phone and it still shows my name as iMessage.
    I logged into "Apple Support - My Support Profile" to try to unregister my device as suggested in another forum but I can't get past the "enter your purchase date" page. It was a refurbished iPhone and the date I purchased the device didn't work. Theres no way I'll ever get the original purchase date since I wasn't the original buyer of that iPhone.
    Any suggestions?? This is an urgent matter as I NEED to receive text messages from my wife and other iPhone users. My wife is willing to turn off iMessage on her iPhone but I don't expect everyone else to.
    I need to find out how to unreigster my old iPhone completely from iMessage.... or find out how to disable a specific contact on my wife's iPhone from using iMessage.

    If you still have an iPhone handy and have the SIM card you used for the phone, then temporarily put your SIM into the other phone and go into Settings and turn of iMessage. If not, the only alternative that I know of is the Support profile, However, you may what to search the More Like This section on the right side of the thread to see if any of the entries there have a green checkmark meaning they are answered.

  • How to disable automatic opening of previously viewed items in Preview or TextEdit in Max OSX Lion?

    How to disable automatic opening of previously viewed items in Preview or TextEdit in Max OSX Lion? It was no such issue on Snow Leopard OS.
    Please help

    This is a new behavior introduced in Lion.  You can disable it completely via System Preferences, General: uncheck the "Restore windows..." box toward the bottom. 
    You can disable this behavior on a case by case basis by either closing all windows before quitting, or holding the option key while quitting, or holding the shift key while launching from dock.
    charlie

  • How to disable a field in a standard transaction

    Good day,
    Can any one tell me , with an example of , how to disable (the field should not allow any input ) a parameter  or a select option in a standard transaction.

    Probably the only way to achieve this is by creating transaction variants:
    In the SAP Reference IMG, you can create transaction variants. Choose Basis Components ® Application Personalization ® Tailoring of Application Transactions ® Configure Transaction-Related Display Values for Fields (Transaction SHD0). Transaction variants allow you to preset values for fields in a transaction, set field attributes, or hide entire screens.
    To execute a transaction variant, you define a variant transaction using the Transaction Maintenance transaction (SE93).
    Once you have entered a transaction code and short description, choose transaction type Transaction with variant (Variant transaction).
    To define a variant, enter the name of the transaction and the name of the variant. You can then use the new transaction code to start the special variant of the transaction.
    Steps :-
    Transaction SHD0 - Create a variant for the required transaction bychanging the layout through hiding fields and screens.
    Transaction SE93 - Create a variant transaction (e.g. for VA02 you canname it as ZA02). Next allocate the transaction variant to this varianttransaction.

  • AMFPHP and AS3FLEXDB - how to disable 'busy indicator' during query execution ?

    I'm doing some experiments with Flex and SQL with use of as3flexdb and AMFPHP.
    I've written some application which is pushing some data to SQL base...
    problem is, that durring query execution, there is some 'busy indicator' on the screen
    - some circle, and word 'loading'.
    Have you any idea how to disable this ?
    Everything what I'm doing is based on this tutorial below, but there is no idea in it how to
    disable the indicator.
    http://ghalex.com/blog/tag/as3flexdb
    I'm not sure if this indicator comes from as3flexdb libraries or AMFPHP itself ?
    Has anyone of you had such problem before ??
    Thanks for all ideas
    Rymas,

    Unfortunatelly my cheers was to early
    I've successfully decompiled the library swc file, found Query.as class and corrected things mentioned in this
    post : http://itutorials.ro/viewtopic.php?f=9&t=22&p=59&hilit=loading#p59
    ... but I cannot compile the library.fla back to swf ... it's generating some errors
    Could anyone help me with that, maybe you've got more expirience with decompiling and compiling.
    Orginal .swc file is here : http://www.rymasek.iq.pl/swc/as3flexdb_1.3.0.swc
    Thanks for help !!

  • How to disable end user personalisation for all webdynpro application.

    Dear Experts,
    I have a requirement where I have to disable the end user personalization of each and every
    webdynpro application in my server.
    I know how to disable the personalization of a single application or a single component, but my requirement is to disable the personalization of all applications.
    Request you to please suggest.
    Warm Regards,
    Upendra Agrawal

    Hi,
    As per SAP help,
    Customizing: User-Independent, Client-Wide Modifications
    While a single user u2013 during a personalization process u2013 can manipulate his or her own settings, an administrator has the option of executing Customizing settings for all users. Technically, this procedure is not different from personalization; both take place at runtime of an application. The difference lies in the range of the settings. In addition, for these global settings an application must run in a special administration session. This is always automatically the case if an application was started in the portal in the preview session. Independently of the portal, you can start an application in the following manner from within the workbench in administration mode:
    Double-click the name of the application in the object list.
    In the Web Dynpro Applications menu in the upper, left-hand corner of the Workbench window, choose  Test  Execute in Admin Mode .
    The configuration mode is passed to an application as the sap-config-mode=X URL parameter.
    Note
    All the adjustments made by the administrator in admin mode are stored as client-specific. Presently no option is available for structuring smaller user groups on an administrative basis. Since cross-client adjustment applies to the respective configuration, the structuring of smaller groups can be implemented currently through the maintenance of different configurations.
    End of the note.
    You start personalization by calling up the context menu for the respective UI element in your application. In the corresponding context menu for an administrator (that is, with URL parameter sap-config-mode=X), in addition to the standard settings administrators have the option within a UI element container to sort either single lines (Grid, Matrix aund RowLayout) or single elements (FlowLayout).
    Note
    Administrators require special authorization for client-wide modifications. This can be a developer authorization or the special authorization S_WDR_P13N. You cannot create configurations at design time with this authorization, but you can make modifications at runtime.
    End of the note.
    These modifications are valid for all users but take place in the current client only.
    Thanks,
    Chandra

  • NI-DAQmx Base 3.2

    hi,
    As far as I know, NI-DAQmx Base 3.2 can create channel for voltage and thermocouple. How may I create channel for acceleration and pressure?
    Thank You for helping

    Hi,
    Thank you for your reply.
    In DAQmx create channel drop-down menu, we have acceleration and pressure. But, in DAQmxBase create channel drop-down menu, we do not have acceleration and pressure. That's the reason why I doubt we cannot use DAQmxBase for acceleraion and pressure.

Maybe you are looking for

  • I-phone calendar settings

    looking to find out if anyone has seen an update for the calendar on the i-phone. nothing major just a pet peeve. when you add an appointment and wish to repeat the appointment, you are only given a few options. eg., i wish to repeat something every

  • MFBF - Read BackFlush Error message

    Hello friends, Can any one advice me how to read the Backflush error message text in MFBF transaction from se38 program while doing BDC. Thanks for immediate reply guys. Regards, Siva

  • Using win7 and IE I am unable to successfully download an interactive document for completion online

    I use Window 7 and Internet Explorer and Acrobat XI to download an eletter for completion on line. The down is completed but the Acrobat window remains grey and no content is displayed and the window freezes.

  • PLSQL api to get current URL

    I am looking for a PLSQL API to return the URL Of the currently displayed page ie an equivalent to the JPDK call to PortletRenderRequest.getPageURL(). Thanks null

  • Is Adobe Coldfusion Enterprise V10 supported by Solaris 11 OS?

    Hi I have a customer looking at Colfusion Enterprise but want it to run on a Solaris v11 Operating System. There appears to be some confusion in some of the tech specs that  it may not be, so am looking for clarification. thanks