L_TO_CREATE_SINGLE  -  new storage unit is not created by SAP

Hello Friends,
I am using a FM L_TO_CREATE_SINGLE to create transfer order.
But, When I am not passing Destination SU as import parameter, it gives me following error.
"Storage unit XXXXXXX is not consistent with other transfer order data"
This is happening in ECC 6.0. Earlier i was using ECC 5.0 and there was no problem.
How can I get rid out of this problem?
Regards,
RH

Hi,
Check the long text of the message.
It clearly says that
"Data in the transfer order item (such as the quant number, storage bin or storage type) does not belong to the storage unit number that you entered."
So check to see if the storage unit number you entered is correct.
This seems to be a data issue.
Regards,
Ankur Parab

Similar Messages

  • To Create New Storage Unit Automatically

    Hi all,
    I need some info for creating storage bin. I have a material with 100 KG in a storage unit XYZ. And i want to move 20 KG of 100 KG to new storage unit.
    First i call BAPI_GOODSMVT_CREATE with movement type 311 with new quant 20 KG to create a new storage unit. After that i call L_TO_CREATE_POSTING_CHANGE for transfer posting.
    But it does no effect to material. It have 311 movement successfully but than it puts the 20 KG to the same storage unit XYZ. How can i move it to a new storage unit ?
    Regards,
    techmaster

    If you only want to do a WM transfer (manually with LT01), you can use L_TO_CREATE_SINGLE.
    Best Regards, Dirk

  • CUNI - Creation of new unit - error Unit is not created in language EN

    Dear BI community,
    We have created via transaction CUNI a new unit. Everything looks fine - it appears in the unit of measurement and the conversion works.
    The problem only occurs when we check it in table T006A by example. When looking for it we get the following error message
    "Unit is not created in language EN".
    We have tried the "translation" option of CUNI but when we select another from language than EN we get not value.
    Any idea?
    Thanks,
    Rodolphe

    Hi All
    We have the same issue.
    Please let us know how could you fix this issue.
    Thanks

  • I'm trying to downgrade my storage on my ipod but when I chose my new storage i'm not able to complete the choice because the 'done' button doesn't do anything. can someone please give me some advice?

    I'm trying to downgrade my storage on my ipod but when I chose my new storage i'm not able to complete the choice because the 'done' button doesn't do anything. can someone please give me some advice?

    Are you choosing a different plan before tapping Done?
    To downgrade, you should be doing the following:
    Go to Settings > iCloud > Storage & Backup.
    Tap Change Storage Plan.
    Tap Downgrade Options and enter your Apple ID password.
    Choose a different plan to use when your current storage plan expires.
    Tap Done.

  • Unit *** is not created in language EN - POSDM in CAR 1.0

    Hi all,
    I am getting the error message "Unit *** is not created in language EN" (Message no. BM305), while creating POSDM transaction.
    I did set up and loaded data into BI components 0MATERIAL, 0PLANT, 0RPA_MEAN, 0MAT_PLANT & 0RPA_MARM.
    I have verified that tables T006 & T006A are having Unit of measure 'EA' with language English.
    When I used Tcode 'CUNI' and gave source and target language as EN. I am getting error message 'Could Not Save Target Text'. But this would not be an issue I guess, because I have verified a working system source/Target were not maintained there.
    Please let me know if any further setting to resolve the issue.
    Thanks,
    Venkatesan

    Thanks Vikrant for your reply.
    Actually I have used flat file upload, and ensured that the Infoobjects are mapped properly.
    When I use POSDM Workbench, I am getting error like 'Unit EA is not created in language EN'. T006/T006A are having UoM in language EN. Is any other common setting I am missing here?
    0RPA_MARM - has only attributes? Do I need to upload TEXT for this object?
    Thanks,
    Venkatesa

  • 'unit STD not created in language RO'

    Hi there everyone
    system outputs error message: 'unit STD not created in language RO' while loading the cube YSD_C03 (transaction SM37- in job log). (The loding process ends with error.) Why is that?
    the same message or the like appears in transaction 'Monito for qRFC' in source system, for Data Source : 2LIS_13_VDITM, on the bottom of the screen.
    Thanks for taking the trouble!

    Hi,
    Seems the unit is not maintained for the language Romanian in the source system.Nut you are getting some data in the R/3 transaction data for that.
    just check the table T006A and see if this unit STD is maitained against the Romanian language or not??
    May be you can ask your R/3 team to create it or change the document.
    Thanks
    Ajeet

  • Unit *** is not created in language

    Dear all,
    in SAP CRM WebUI when I'm trying to create ERP Sales order from ERP Quotation in a follow up process I get the error "Unit *** is not created in language EN".
    CUNI settings are OK in both ERP and CRM systems.
    In a web page dialog when I want to confirm/choose the items to get copied into ERP Sales order I get the item shown in as 1 *** (instead of 1 PC - piece). When I confirm, in the next step system raise the error message.
    Same scenario happens on all languages.
    Any idea how to solve this is most welcome.
    Best regards.
    Hrvoje

    CUNI setup (units of measures) in both systems is equal and seems OK.
    Creating ERP sales order from reference to ERP quotation in ERP itself is working with no problems.
    Best regards,
    Hrvoje

  • Unit *** is not created in language EN

    Hi,
           In ME22N when I tried to create a service line item directly (with out referring to any reference document) by providing the values I am getting an error message 'Unit *** is not created in language EN'. Even though I mention the correct UOM values for screen fields (MEPO1211-MEINS,MEPO1211-BPRME).
            I couldn't find where it is replacing the UOM value with '***' and then calling the conversion exit for Unit and triggering this message. Did anyone encountered this message. Once this message pops-up there is no option to get out of the screen (only by using /n). Please suggest me how we can fix this issue.
    Regards,
    Bhanu

    Hi,
    Go to transaction CUNI.
    Select the Unit of Measure from the drop down list and check the entries for UoM's.
    Check for the entry with an English description.
    If the above entry is available, then check for the case sensitivity of UoM.
    also,
    GO TO --> Translations --> Unit of Measuremnts
    here select EN to EN
    This may help u
    Regards,
    Rahul.

  • Can i print Storage Unit number as barcode in SAP??

    can i print Storage Unit number as barcode in SAP and also Scan the same number in RF devices.

    Hello,
    yes you can, the solution depends on which printer do you have, if you want to print on laser or label printer.
    Please explain your requirement in more details
    Christophe

  • Org unit relations not created

    Hi Experts,
    We are facing one issue. When there is large change in HR data then 3-4 IDOC came into SRM system. Generaly first IDOC carry new org unit information abd second IDOC carry relation of Org unit with higher org unit. As IDOC processes simultaneously, second idoc is not able to cerate relations as org unit is not yet created from first IDOC.
    Please advise if someone faced similar kind of issue and how to solve it.
    Regards,
    Raj

    hi,
    Please maintain the values in the PP01 table for the respective postion.
    BR,
    Satish.

  • Storage unit type not found automatically on LT01

    Hi,
    We have just only one kind of storage unit type in the settings. I want it to be determined automatically on TO creation(LT01) , so that the user is not required to enter it everytime he creates a TO
    I couldnt find a way to do it via custimizing.  Appreciate any tips about it.
    Thanks
    Cihan Polat

    Hi,
    I dont have a problem with storage type determination.
    Acctually what is missing on LT01 is storage type indicator LTAP-LETYP (EXP for my example).
    This is the field on the second screen of LT01 (SAPML03T- 102).
    It is located under quantity, which is just second line  on the screen.
    Requested qty    1                 PC   5SQ2 370-0KA06  /N-OTM.C6  3pol     
    Stor. unit type      EXP                   Material        5SQ23700KA06        
    Certificate no.                         Plant/Stor.loc. 1000   1550         
    Confirm                                                                     
    Printer                                 Stock category                      
    GR date          12.04.2010             Special stock                       
                                            TO item         0                                                                               
    Tpe Sec Stor.bin    Target quantity   AUn                                                                               
    Src                                         0 PC                                                                               
    Dest                                        0 PC                                                                               
    Ret.                                        0 PC                                                                               
    Goods recipient                         Weight                   0,000

  • New spool number is not created .. appending to prevoius  spool

    Hi friends
    we have requirement to print smartform labels for each Delivery item.
    i created smartform and written code in User Exit..
    but spool is creating first time and next label onwards label is appending to the old spool instead of creating new spool( for the second label new spool is not created,its taking prevoius spool number , checked in debugg as well)
    Please help me..
    i have writeem code as follows:
    CALL FUNCTION 'SSF_FUNCTION_MODULE_NAME'
    EXPORTING
    formname = p_sf_name
    IMPORTING
    fm_name = fm_name
    EXCEPTIONS
    no_form = 1
    no_function_module = 2
    OTHERS = 3.
    wa_outop-tdimmed = 'X'.
    wa_control_parameters-no_dialog = 'X'.
    wa_control_parameters-device = 'PRINTER'.
    wa_control_parameters-preview = ''.
    wa_control_parameters-langu = 'EN'.
    wa_outop-tdarmod = 1.
    wa_outop-tdimmed = 'X'.
    CALL FUNCTION fm_name
    EXPORTING
    output_options = wa_outop
    user_settings = space
    wa_label_data = wa_label
    control_parameters = wa_control_parameters
    EXCEPTIONS
    formatting_error = 1
    internal_error = 2
    send_error = 3
    user_canceled = 4
    OTHERS = 5.
    Thanks
    Ramesh

    Hi,
    You need to pass X to parameter OUTPUT_OPTIONS-TDNEWID
    Try like below:
    CALL FUNCTION 'SSF_FUNCTION_MODULE_NAME'
    EXPORTING
    formname = p_sf_name
    IMPORTING
    fm_name = fm_name
    EXCEPTIONS
    no_form = 1
    no_function_module = 2
    OTHERS = 3.
    wa_outop-tdimmed = 'X'.
    wa_control_parameters-no_dialog = 'X'.
    wa_control_parameters-device = 'PRINTER'.
    wa_control_parameters-preview = ''.
    wa_control_parameters-langu = 'EN'.
    wa_outop-tdarmod = 1.
    wa_outop-tdimmed = 'X'.
    wa_output-TDNEWID = 'X' .            "ADD
    CALL FUNCTION fm_name
    EXPORTING
    output_options = wa_outop
    user_settings = space
    wa_label_data = wa_label
    control_parameters = wa_control_parameters
    EXCEPTIONS
    formatting_error = 1
    internal_error = 2
    send_error = 3
    user_canceled = 4
    OTHERS = 5.
    Regards,
    Himanshu

  • New Storage Check setting not working - Lumia 920

    I received the new update yesterday but the new "Storage Check" doesn't work.  I see it in settings but when I click on it  it looks like it is going to do something (page flip animation) but then it goes right back to the settings.  Does anyone have this issue or know how to fix it?  I have done a soft reset and turned it off a few times.  I do not want to do a hard reset because I recently did this and I have the phone the way I like it.

    Guys, I'm form India.
    Just updated my Lumia 920 to new firmware version 1308.0001
    As reported by others, I have the same problem. My ''storage check'' option is not working at all!
    It keeps on loading.
    What to do?? Please help!
    Attaching a screen shot.
    Attachments:
    wp_ss_20130409_0002.png ‏110 KB
    wp_ss_20130409_0003.png ‏100 KB

  • Sapdata3 has been not created after Sap Neatweaver 7.3

    Hi Gurus,
    I have done the installation for SAP Netweaver 7.3 Java stack with distributed option with oracle database .
    However file system created is sapdata1,sapdata2 , and sapdata4 has been created but sapdata3 is not created .
    can any one susggest.
    Regards,
    Jeetendra

    Hi Jeetendra,
    Check whether you system is up and running ?
    If yes, then sapdata3 is a folder created under /oracle/SID or /oracle based on your file system structure.
    As right mentioned SAP installer will not create any file system. If file system /oracle/SID/sapdata3 is not available, SAP installer will create a folder sapdata3 under /oracle/SID and respective data files will be created under the same.
    Hope this helps.
    Regards,
    Deepak Kori

  • Sales order do not create after SAP upgradation to package EHP7

    Dear Experts,
    SAP client is recently upgraded to EHP7. Since then we are observing difficulty in Sales order creation [VA01] manually [with or without order reference].
    When click on SAVE button, entire screen display get freezed, without any message [Error/Information/Warning] pop-up. it seems as if system was trying to display message; caused due to any kind of event occurrence; but unable to show up.
    Moreover, when we click on "BACK" or "EXIT" button, then it prompts choices to save the data. Yet again we receive the same freeze response whenever chose "Yes" option.
    Please note:- before up-gradation, we were able to create orders with the same data, what we are using to create now.
    Any help or clue on this subject would be highly appreciated.
    Thank you for all your help.
    Best regards,
    Rahul Agarwal

    Hi,
    did you check what are the sales orders Enhancements that are activated with EHP7 under T.code-SFW5

Maybe you are looking for

  • Verizon iPhone - mobile hotspot and other questions about the data options

    I just ordered the Verizon iPhone. Can anyone explain the options here: 1) Unlimited corporate email & Web (business and personal email) vs. Unlimited email and web for smartphones (personal email) - what's the difference? 2) "3G Mobile Hotspot 2GB"

  • Help needed  in writing a Query/Procedure

    Hello All, Need all ur help in writing a query or procedure Lets say the Table name is DEMO There i have one column like num it has values 1 2 3 4 5 8 9 10 my query output should be 1-5 8-10 i,e .. if the diff between two rows is greater than 1 then

  • Airport Extreme Base Station not cooperating with Cable Modem

    The non-specific issues are by far the most frustrating and I can't make any sense of this. To be fair, this might not be a AEBS issue as much as a ISP issue, but any suggestions are much appreciated. History: My setup has worked great for about 6 mo

  • Testing Adapter Module in NWDS

    hi, I have got a code for adapter module,I wanted to test it standalone using NWDS. class XML2EdifactBean public ModuleData process(ModuleContext moduleContext, ModuleData inputModuleData)           throws ModuleException { //Some Code... } I am gett

  • Planning application Migration

    Hi I referred earlier migration post Migration of Hyperion Planning Application and come out with one thing related to SID, If the application owner for the target application is different: Go into the database tables for the planning app and look at