Hi Experts,
I am trying to extract IBM InfoSphere DataStage metadata into SAP IS central repostiory for metadata managment impact and lineage analysis. For the i created MIMB integrator source with IBM InfoSphere DataStage type and used DataStage extract DSX file to import the metadata. The integrator source connection is succussfully created without any issues.
Then I ran the Integrator Souce to start extracting the metadata, the task is running from hours and still continueing. The Database log of the task is shwoing as below, and from there it is not moving further.
[I] 2014-04-09 08:33:33.014 Information Steward version
14.2.0.411.
[I] 2014-04-09 08:33:33.033 Starting utility
MITI.bridges.bo.mm.MimbIntegrator. (COR-10013)
[I] 2014-04-09 08:33:33.034
Process ID = 8080 on machine XXXXXXXXXXXXXXXXXX
[I] 2014-04-09
08:33:33.189 Connected to the Information Steward repository at
jdbc:sqlserver://XXXXXXXXXX:1433;databaseName=IS_REPO. (COR-10017)
[U]
2014-04-09 08:33:42.532 Argument -configurationObject = 54093 (COR-10206)
[U]
2014-04-09 08:33:42.532 Argument Encoding = iso-8859-2 (COR-10206)
[U]
2014-04-09 08:33:42.533 Argument File =
C:\Windows\TEMP\sda_dev_extract.5762502273886146081.dsx (COR-10206)
[U]
2014-04-09 08:33:42.534 Argument Import scope = All supported objects
(COR-10206)
[U] 2014-04-09 08:33:42.535 Argument Variable values file =
(COR-10206)
[U] 2014-04-09 08:33:42.536 Argument batch = true
(COR-10206)
[U] 2014-04-09 08:33:42.537 Argument batchRetryCount = 4,320
(COR-10206)
[U] 2014-04-09 08:33:42.538 Argument batchRetryInterval = 10,000
(COR-10206)
[U] 2014-04-09 08:33:42.538 Argument boeAuthentication =
secEnterprise (COR-10206)
[U] 2014-04-09 08:33:42.539 Argument
boeInfoObjectId = 54093 (COR-10206)
[U] 2014-04-09 08:33:42.542 Argument
boeServer = XXXXXXXXXXXXXXXXXXXXXXX(COR-10206)
[U] 2014-04-09
08:33:42.544 Argument boeUser = Administrator (COR-10206)
[U] 2014-04-09
08:33:42.544 Argument bridgeId = AscentialDataStage (COR-10206)
[U]
2014-04-09 08:33:42.546 Argument className = MITI.bridges.bo.mm.MimbIntegrator
(COR-10206)
[U] 2014-04-09 08:33:42.547 Argument deadlockRetryCount = 10
(COR-10206)
[U] 2014-04-09 08:33:42.548 Argument dl = INFO (COR-10206)
[U]
2014-04-09 08:33:42.549 Argument enableNewDBOptimization = true
(COR-10206)
[U] 2014-04-09 08:33:42.550 Argument fl = CONFIG
(COR-10206)
[U] 2014-04-09 08:33:42.551 Argument fullExtract = false
(COR-10206)
[U] 2014-04-09 08:33:42.551 Argument maxConnections = 10
(COR-10206)
[U] 2014-04-09 08:33:42.553 Argument repoConnectionTimeout =
3,600 (COR-10206)
[U] 2014-04-09 08:33:42.554 Argument repoOverridePermitted
= false (COR-10206)
[U] 2014-04-09 08:33:42.555 Argument sqlTopLimit =
1,000,000 (COR-10206)
[U] 2014-04-09 08:33:42.555 Argument validationLevel =
BASIC (COR-10206)
[I] 2014-04-09 08:33:43.125 Started execution on 2014-04-09
08:33:32. (COR-10014)
[I] 2014-04-09 08:33:43.780 Utility processing
starts.
[I] 2014-04-09 08:33:46.654 Running MIMB...
Environment Details:
SAP IPS : 4.0 SP 5
SAP Data Services: 4.2 SP0
SAP Information Steward: 4.2 SP0
Metadata Source : IBM InfoSphere DataStage 9.x
DataStage Extract Format used: .DSX
IS Repository Database: MS SQL SRV 2008 R2
Thanks,
Ramakrishna Kamurthy

Hi Adrian,
I too facing the same issue, finally after lot many tries i registered an incident in OSS for SAP support. But till now i didn't get any reply / resolution from SAP, will update you when i get reply from SAP. Also please update if you get find any solution.
Thanks,
Rama

Similar Messages

  • Powerdesigner Integrator Source hangs forever

    Hi,
    We're struggling with Powerdesigner integration. We use PD16.5 and IS14.2.2.412
    The Powerdesigner Glossary is synchronised succesfully to Information Steward.
    However,  as soon as one model is added to the PD repository (conceptual, logical or physical), the synchronisation hangs forever.
    The integrator source seems to loop forever:
    - sets a lock every 10 minutes,
    - log some audit records
    - wait 10 minutes.
    We have tried different repository content scenario's,  even with one physical model, containing one entity  the synchronisation loops forever.
    Synchronisation with BO Webi, SAP DS, SAP BW and HANA works fine.
    I have attached the log file (in the end, we have aborted the loop).
    The proces sometimes aborts with the message "Could not obtain batch lock after configured retries"
    Any suggestion appreciated.
    Gijsbert Karens
    Message was detailed by: Gijsbert Karens on 11/7

    Create a new account (systempreferences -> accounts or Users & Groups on 10.7)  and see if the problem is repeated there. If it is, then a re-install of the app might be indicated. If it's not, then it's likely the app is okay and the problem is something in the main account.
    Regards
    TD

  • Integrated Source Control doesn't honor given username after restart of LabVIEW

    I don't really like the integrated Source Control of LabVIEW 8.20 due to some missing features and failures which happen. But for a presentation I had to get some practical information. As SCC API provider I selected Microsoft Visual Source Safe for an example project. While playing around I noticed following bug in the implementation for LabVIEW.
    All given information to access the SCC provider is saved inside 'labview.ini' (which is IMO not the correct place, especially when you are working with different projects). As user I selected 'admin' and not the logged on system user. Access to the repository is granted within the current session and I can do all operations. But if you restart LabVIEW it cannot access the repository because it uses the system user and not the given username to log into the repository.
    If you wan't to work with the integrated Source Control each user who should get access to the repository should have an own user account with the same username as his Windows account.
    This is one of a number of bugs since a couple of versions which don't let me use the integrated Source Control.
    Henrik

    Due to following items I don't want to work with the integrated source control:
    1. All SCC options are stored inside the file 'labview.ini'. That makes you unimpossible to work with different projects without reconfiguring the SCC again and again. Each project should hold it's own SCC options which overrides the LabVIEW global SCC options. If you are working without projects the global SCC options should be used.
    2. If you don't have access to the repository (e.g. network disconnected) you get an error message each time you open a vi (last tested with 8.0 a long time ago). LabVIEW should silently fail and give me at maximum one alert that the connection to the repository cannot be established. Opening the SCC options you can see that everyting is resetted while the correct configuration is still located inside the 'labview.ini'. You have to delete them manually inside the configuration file.
    Both parts are already reported to NI in february last year.
    3. Comparing two different versions of one file is not working unless you compare the current local version with the latest version inside the repository. Using subversion I can do that by integrating metadiff and lvdiff. It is more than helpful.
    4. You have to use an external scc client to create a branch or tag.
    5. That's a personal thing but I like the way of using update/commit instead of checkout/checkin.
    Dunno if I remember all the things I missed while testing the integrated source control some time ago.
    Henrik

  • Kann mit Bridge CC über Netz nicht bewerten

    Ich habe auf einem Notebook  (Win7 64 Bit) Bridge CC installiert und greife auf die Bilder auf meinem Hauptcomputer (Windows 7 Ulimate 64Bit) zu.
    Funktioniert allles einwandfrei - bis auf das Bewerten. Die Sterne erscheinen beim Darüberfahren mit der Maus, verschwinden aber sofort wieder
    wenn der Mauszeiger weg ist.Über Menü/Beschriftung bewerten,  funktioniert ebenso nicht.
    Die Zugriffsrechte müssten passen, denn ich kann die Fotos mit Bridge sogar löschen.
    Bridge CC ist aktualisiert.
    Das Bewerten auf dem "Foto-Speicherort-PC" funktioniert einwandfrei.
    Hat jemand eine Idee ?

    Ich kann warten solange ich möchte, da tut sich nichts
    Bridge schreibt die Bewertung erst wenn man die gedrückte Maustaste auf den Sternen loslässt.
    Das sieht man an in der Statuszeile. Dort steht dann für den Bruchteil einer Sekunde:
    "Metadaten werden in "Dateiname des Bildes" geschrieben.
    Wenn ich auf dem Haupt-PC bewerte wird auch auf dem Notebook die Bewertung umgehend aktualisiert,
    es erscheinen die Sternchen. Umgekehrt ist nichts zu sehen.
    In Bridge wird das Bewerten sogar dokumentiert, denn ich kann es angeblich mit Undo sogar wieder rückgängig machen.
    Unter Bearbeiten steht nach dem angeblichen Bewerten  "Rückgängig:Bewertung"
    Wenn das Löschen nicht ginge würde ich wetten es ist ein Berechtigungsproblem aber so....

  • Is a Video Card Much Better Than Sandy Bridge Integrated Graphics?

    Windows 7 Pro 64bit
    Does Photoshop benefit much from an Intel Sandy Bridge I2500K CPU computer having a video card?
    The Sandy Bridge CPU, of course, has greatly improved on-board graphics compared to prior incarnations of Intel's CPUs.
    If a video card is useful for PS, how powerful ought it be to achieve a good cost/benefit ratio, or which one is recommended? (the so-called sweet spot of price and performance)
    Does it matter whether it's an AMD or NVidia type?

    Do either of you two (Silent785 or Mylenium) have personal experience with a Sandy Bridge integrated GPU?  Just wondering.
    I have not evaluated a Sandy Bridge GPU myself.
    TomBrooklyn wrote:
    If a video card is useful for PS, how powerful ought it be to achieve a good cost/benefit ratio, or which one is recommended? (the so-called sweet spot of price and performance)
    Does it matter whether it's an AMD or NVidia type?
    I've found that you want a video card that scores at least 500 on this benchmark for best Photoshop performance, ideally 1000 or more:
    http://www.videocardbenchmark.net/
    The specific card I'd recommend right now today is a VisionTek ATI Radeon HD 6670 1 GB GDDR5, because it's a great compromise between quiet/low power operation and high rendering speed.
    As an OpenGL developer of 2D graphics software myself, I can tell you that in my experience ATI makes the best structured, most stable display drivers (and are least likely to break something with a new release), followed fairly closely by nVidia.  Intel has been a distant third, but one can imagine that if they're integrating GPUs on their processors now that they might better-fund a development team to make their OpenGL implementations more solid.
    -Noel

  • ERP Integrator Source Informations

    Hi All,
    I would like to know whether ERP Integrator will support the External feed file(from any other source system) to Hyperion Applications. ERP Integrator will support all ORACLE ERP & HR Modules, but in terms of external system likes Customized ERPs it will support or not. I understood from the below content, it will support the external system through Open Interface Adapter. I couldn't find any document on Open Interface Adapter.
    Anyone having the experience on the above scenario, Please share your experience and let me know is there related document or URL..
    I got the below content from the Oracle documents:
    ERP Integrator supports general ledger data for:
    Oracle E-Business Suite 11i
    Oracle E-Business Suite 12
    Oracle Fusion Financials
    PeopleSoft Enterprise Financial Management 9.0
    PeopleSoft Enterprise Financial Management 9.1
    PeopleSoft Commitment Control
    SAP ERP Financial
    JD Edwards General Ledger system
    ERP Integrator supports human resource data for:
    PeopleSoft Human Capital Management 9.0
    Integration includes data load and drill through. The integration is supported for the following SAP ERP Financial modules:
    General Ledger
    Profit Center
    Cost Center
    In addition ERP Integrator provides support for Open Interface Adapter. The Open Interface Adapter allows you to import data from any source system using the interface table.
    Thanks,
    PC

    Hi All,
    Got the Answer, The ERP Integrator will support external feeds files through FDM as well as they introduce Open Interface Adapter for flat files in new version(11.1.2.2). Please refer FDM ERP I read me document for more details. Currently i dont have any information for Open Interface Adapter. I will let you post the same once i got the reference materials.
    Thank you for all your support.... :)
    Thanks,
    PC

  • Creative Cloud für Fotografen - Mit Bridge?

    Hi,
    ich bin am überlegen mit des Creative Cloud Paket für Fotografen zu holen. Ist bei diesem Paket auch Adobe Bridge dabei?
    Wenn nein wie kann ich es dazu buchen?
    mfg

    Bridge ist - wie früher eben auch - überall "kostenlos" schon dabei.
    Mylenium

  • Probleme mit Bridge und Nikon D2X

    Ich habe einen Mac mit OS 10.4.1, Photoshop CS2 und Bridge 1.0.1. Wenn ich von einer Nikon D2X Raw-Dateien auf die Festplatte übertrage, erscheint in Bridge nur ein Ikon für eine NEF-Datei, eine Vorschau des Bildes wird aber nicht angezeigt.
    Was kann ich tun?

    @ Wilhelm
    Leider doch, laut Nikon kann Photoshop RAW-Dateien der D2x erst nach dem Update lesen zumindest bis zur Version CS.
    Für CS2 will ich dies jetzt nicht unbedingt behaupten,wäre aber vielleicht eine Möglichkeit.

  • Problem mit Bridge CS 4 nach Update auf Windows 8.1

    Wenn ich in Bridge auf den Button Bearbeiten gehe und dann auf Voreinstellungen Camera-Raw gehe kommt dieses Popupfenster:
    Was muss ich veranlassen, damit dieser Fehler nicht mehr erscheint. Camera Raw 5.7 ist installiert.
    Freue mich auf eine schnelle Antwort.
    Ich habe leider keine Antwort aus dem Forum erhalten, aber ich habe das Problem selbst gelöst:
    Das CS4 -Programm muss als Administrator gestartet werden und einmal starten, ohne dass die Bridge vorher schon gestartet ist. Anschließend aus Adobe heraus die Bridge öffnen und alles Probleme sind verschwunden!!!!!
    Bei mir hat es auf jeden Fall geklappt! Ich hoffe, dass anderen Anwendern damit auch geholfen werden kann.

    Hallo hekame,
    waren die Tips in diesem Thread nicht hilfreich?
    Gruß
    Sebastian
    → Wenn Du eine Lösung auf Deine Frage erhalten hast, markiere diese bitte als gelöst - Hilfreiche Beiträge verdienen Kudos. Zögere nicht Kudos zu vergeben.   

  • Problem mit bridge cs5

    hallo,
    die vorschau in der bridge cs5 zeigt keine beschneidungen der bilder an,die restlichen bearbeitungen im konverter werden aber angezeigt???
    kann jemand helfen??

    bei mir werden die beschneidungen korrekt angezeigt!

  • MIT Kerberos integration via Oracle ASO for Instant Client

    Is Oracle planning on adding support for the Oracle ASO module (specifically for the use of MIT Kerberos authentication) to the Oracle Instant Client?
    Last time I checked (about 2 years ago) they had not, but I'm hoping they are working on it.
    Update: I originally posted this back in Feb 2007, and now it's June 2007...... No replies..... Does anyone know if Oracle will add support for MIT Kerberos Authentication to the Instant Client?
    Message was edited by:
    dkwhisle

    I haven't seen many requests of ASO support being requested for Instant Client nor have I heard of it being included any time soon (in any Instant Client-related press). You should pose the question to Oracle support or your Oracle sales representative.

  • Weigh bridge Integration

    HI
    How we can PO - Good Receipt through Weighbridge ( MettlerToledo-8142 PRO ) in ABAP .  without using VB program ( Visual Basic).
    thanks
    Thomas

    Hi,
    you can use the RFC HU_GET_RFC_DATA to retrieve the weight from a scale connected to the user's PC via a com (RS-232) port. You can use this RFC from a custom ABAP for the GR process or in a user-exit.
    You can view sample code here [RFC HU_GET_RFC_DATA|http://www.en.pocketprograms.com/support/abapsamples.aspx] example.
    Good luck !
    Ian

  • MQ Series, Messaging Bridge, weblogic 7.0

              Hi all,
              I have seen other postings about this with some clues as to why I am having this
              problem, but I still can't seem to resolve. I have already tried to gleen some
              clues from the documentation that comes with the beta bridge to be used with 6.1
              (wls_mqseries.pdf). Has anyone configure Weblogic 7.0 successfully with the new
              Messaging Bridge? If so, could you summarize your steps and settings?
              I used the JMSAdmin tool to bind the factory and queue objects and setup the destinations
              on the WLS console, but the log keeps spitting out the following:
              <Jul 26, 2002 11:28:21 AM EDT> <Warning> <Connector> <190032> << Weblogic Messag
              ing Bridge Adapter (XA) > ResourceAllocationException of javax.resource.Resource
              Exception: Failed to start the connection on createManagedConnection.>
              javax.resource.spi.ResourceAllocationException: CreateManagedConnection Error:
              F
              ailed to start the connection
              at weblogic.connector.common.internal.ConnectionPool.makeResources(Conne
              ctionPool.java:993)
              at weblogic.connector.common.internal.ConnectionPool.getConnection(Conne
              ctionPool.java:1762)
              at weblogic.connector.common.internal.ConnectionPoolManager.getConnectio
              n(ConnectionPoolManager.java:163)
              at weblogic.connector.common.internal.ConnectionManagerImpl.allocateConn
              ection(ConnectionManagerImpl.java:25)
              at weblogic.jms.adapter.JMSBaseConnectionFactory.getSourceConnection(JMS
              BaseConnectionFactory.java:97)
              at weblogic.jms.bridge.internal.MessagingBridge.getConnections(Messaging
              Bridge.java:699)
              at weblogic.jms.bridge.internal.MessagingBridge.execute(MessagingBridge.
              java:899)
              at weblogic.kernel.ExecuteThread.execute(ExecuteThread.java:152)
              at weblogic.kernel.ExecuteThread.run(ExecuteThread.java:133)
              <Jul 26, 2002 11:28:21 AM EDT> <Error> <Connector> <190006> <Error granting conn
              ection request.>
              <Jul 26, 2002 11:28:21 AM EDT> <Info> <MessagingBridge> <200042> <Bridge "MQ Ser
              ies Bridge" failed to connect to the source destination and will try again in
              55
              seconds. (javax.resource.spi.ResourceAllocationException: CreateManagedConnecti
              on Error: Failed to start the connection)>
              I can only tell that at startup, WLS is trying to establish a connection. Question:
              Connection to what? I haven't specified an MQ Series host or Queue Manager name
              anywhere yet.
              Thanks for your help,
              Mike Wright
              

              Tom,
              Thanks. The white paper seemed to have the info I needed.
              Now I just need to figure out why the lookup of the MQ objects return javax.naming.Reference
              rather than the actual object. I do have the ibm jar files in the classpath.
              Thanks,
              Mike
              Tom Barnes <[email protected]> wrote:
              >Have you read through the latest integrating foreign providers white-paper?
              > It is
              >available on dev2dev, or you can find it here:
              >http://newsgroups.bea.com/cgi-bin/dnewsweb?cmd=article&group=weblogic.developer.interest.jms&item=9364&utag=
              >
              >Tom
              >
              >Mike Wright wrote:
              >
              >> Dongbo,
              >>
              >> I'm sorry, I didn't want to mislead you to think I didn't read the
              >docs prior
              >> to posting the question. I do have the bridge and both destinations
              >defined.
              >> Here are the settings I am using for the "source" destination.
              >>
              >> Name: MQJMS Bridge Destination Source
              >> Adapter JNDI Name: eis.jms.WLSConnectionFactoryJNDIXA
              >> Adapter Classpath:
              >>
              >> Connection URL: t3://10.9.0.21:9003
              >> Initial Context Factory: weblogic.jndi.WLInitialContextFactory
              >> Connection Factory JNDI Name: mqConnectionFactory
              >> Destination JNDI Name: mqDestSource
              >> Destination Type: Queue
              >>
              >> User Name:
              >>
              >> Using the JMSAdmin tool, I defined the connection factory and queue
              >objects which
              >> were bound to the JNDI tree, obviously.
              >> In order to connect using the IBM connection factory, you have to get
              >an instance
              >> of it and call the setter methods to specify the host, port, mode,
              >channel, etc.
              >> etc. Is weblogic trying to make a connection to MQ Series? How would
              >Weblogic
              >> know these settings without specifying anywhere?
              >>
              >> IBM connection factory: com.ibm.mq.jms.MQQueueConnectionFactory
              >> IBM Queue: com.ibm.mq.jms.MQQueue
              >>
              >> Thanks,
              >>
              >> Mike
              >>
              >> "Dongbo Xiao" <[email protected]> wrote:
              >> >Please see my comments inline.
              >> >
              >> >"Mike Wright" <[email protected]> wrote in message
              >> >news:[email protected]...
              >> >>
              >> >> Hi all,
              >> >>
              >> >> I have seen other postings about this with some clues as to why
              >I am
              >> >having this
              >> >> problem, but I still can't seem to resolve. I have already tried
              >to
              >> >gleen
              >> >some
              >> >> clues from the documentation that comes with the beta bridge to
              >be
              >> >used
              >> >with 6.1
              >> >> (wls_mqseries.pdf). Has anyone configure Weblogic 7.0 successfully
              >> >with
              >> >the new
              >> >> Messaging Bridge? If so, could you summarize your steps and settings?
              >> >>
              >> >
              >> >Here is the online doc
              >> >http://edocs.bea.com/wls/docs70/adminguide/msgbridge.html
              >> >
              >> >
              >> >> I used the JMSAdmin tool to bind the factory and queue objects and
              >> >setup
              >> >the destinations
              >> >> on the WLS console, but the log keeps spitting out the following:
              >> >>
              >> >> <Jul 26, 2002 11:28:21 AM EDT> <Warning> <Connector> <190032> <<
              >Weblogic
              >> >Messag
              >> >> ing Bridge Adapter (XA) > ResourceAllocationException of
              >> >javax.resource.Resource
              >> >> Exception: Failed to start the connection on createManagedConnection.>
              >> >> javax.resource.spi.ResourceAllocationException: CreateManagedConnection
              >> >Error:
              >> >> F
              >> >> ailed to start the connection
              >> >> at
              >> >weblogic.connector.common.internal.ConnectionPool.makeResources(Conne
              >> >> ctionPool.java:993)
              >> >> at
              >> >weblogic.connector.common.internal.ConnectionPool.getConnection(Conne
              >> >> ctionPool.java:1762)
              >> >> at
              >> >weblogic.connector.common.internal.ConnectionPoolManager.getConnectio
              >> >> n(ConnectionPoolManager.java:163)
              >> >> at
              >> >weblogic.connector.common.internal.ConnectionManagerImpl.allocateConn
              >> >> ection(ConnectionManagerImpl.java:25)
              >> >> at
              >> >weblogic.jms.adapter.JMSBaseConnectionFactory.getSourceConnection(JMS
              >> >> BaseConnectionFactory.java:97)
              >> >> at
              >> >weblogic.jms.bridge.internal.MessagingBridge.getConnections(Messaging
              >> >> Bridge.java:699)
              >> >> at
              >> >weblogic.jms.bridge.internal.MessagingBridge.execute(MessagingBridge.
              >> >> java:899)
              >> >> at weblogic.kernel.ExecuteThread.execute(ExecuteThread.java:152)
              >> >> at weblogic.kernel.ExecuteThread.run(ExecuteThread.java:133)
              >> >> <Jul 26, 2002 11:28:21 AM EDT> <Error> <Connector> <190006> <Error
              >> >granting conn
              >> >> ection request.>
              >> >> <Jul 26, 2002 11:28:21 AM EDT> <Info> <MessagingBridge> <200042>
              ><Bridge
              >> >"MQ Ser
              >> >> ies Bridge" failed to connect to the source destination and will
              >try
              >> >again
              >> >in
              >> >> 55
              >> >> seconds. (javax.resource.spi.ResourceAllocationException:
              >> >CreateManagedConnecti
              >> >> on Error: Failed to start the connection)>
              >> >>
              >> >> I can only tell that at startup, WLS is trying to establish a connection.
              >> >Question:
              >> >> Connection to what? I haven't specified an MQ Series host or Queue
              >> >Manager name
              >> >> anywhere yet.
              >> >>
              >> >
              >> >As you can see from the doc I mentioned earlier, you have to configure
              >> >the
              >> >source
              >> >and the target of the bridge (as two JMSBridgeDestination instances)
              >> >and the
              >> >bridge itself (as a MessagingBridge instance). In the JMSBridgeDestination
              >> >instance,
              >> >you have to specify a couple of attributes, including url, initial
              >context
              >> >factory,
              >> >connection factory JNDI, destination JNDI and destination type.
              >> >
              >> >I don't know what you configured from the console, but the bridge
              >instance
              >> >tried to connect to the source destination. Again, I don't know what
              >> >is the
              >> >source
              >> >you configured, therefore not sure if the bridge was trying to connect
              >> >to
              >> >MQSeries or WLS JMS.
              >> >
              >> >Hope this helps.
              >> >Dongbo
              >> >
              >> >
              >
              

  • Image Processor Tab Missing in New Adobe Bridge CC 2014

    In the new Bridge CC you used to have a TAB under tools called Photoshop which you could run the script Image Processor for easily processing jpegs. What has happened to this and is their maybe a new way of processing jpegs to lo-res that I dont know about from tiff or jpeg or does my bridge have a problem?
    I have attached a image grab from my bridge that shows that the tab is not there. I know that you can access image processor directly from Photoshop, but they used to always be linked.

    No, it is still in Bridge CC.
    Did you uninstall Photoshop CC after installing Photoshop CC 2014? If so, that may have removed some of the Bridge integration scripts by mistake. Re-installing Photoshop CC 2014 should replace the scripts.
    and it should give the image processor tab back

  • How do I use Perforce Source Control on a substituted drive

    Hello all,
    I am wrestling my way through using perforce as an integrated source control package in Labview.
    The path has many potholes but seems possible.
    My latest challenge:
    Substituted Paths.
    In a professional source control environment there are many users with many views/workspaces and it is good proactice for each one to have a unique name [user][machine][branchname][myprojectstructure]
    Labview is notorious for requiring fixed, absolute paths due to the way .vi's remember their callers, my previous practice using IBM/Rational clearcase was to substitue ("subst B: ." ) the project root [myprojectstructure] to another drive, say B: for example.  This makes Labview is happy as the paths are now fixed, the developer is happy as they don't have to check out a miriad of files.
    This practice is widespread in the embedded software development world and isn't exactly innovative.
    Perforce
    Clearcase integrated into Labview works seamlessly, you just point the path to the substituted drive and all is well.
    Perforce, not so much.
    The setup options within labview whilst being intuitive and easy to use, don't appear allow this method.
    Does anyone know how to do the equivalent in Perforce?
    Thanks in advance,
    Tim L.
    iTm - Senior Systems Engineer
    uses: LABVIEW 2012 SP1 x86 on Windows 7 x64. cFP, cRIO, PXI-RT

    Thanks John,
    I will see if this works
    I hadn't thought about substituting the drive first and then populating the workspace.
    I can see that this implimentation requires discipline,
    There is a significant danger of refreshing the wrong workspace and trashing modified files.
    Tim L.
    iTm - Senior Systems Engineer
    uses: LABVIEW 2012 SP1 x86 on Windows 7 x64. cFP, cRIO, PXI-RT

Maybe you are looking for

  • Single Transaction code for ALE Configuration

    Hi All, I want to Know is there any Single Transaction code for the ALE Configuration instead of going through SALE, WEDI t-code or with defining logical systems assigning them to clients, creating RFC and Distribution Model, generate partner functio

  • Sandy - a simple text editor

    sandy - a simple text editor Sandy is a X11 text editor with an easy-to-read, hackable C source. It uses GTK+ and GtkSourceView for convenience and is akin to surf, only it is a text editor, not a web browser. Sandy tries to maximize screen estate, m

  • ABAP runtime errors    SAPSQL_ARRAY_INSERT_DUPREC

    Hi, Its a production dump.I know the functionality of this dump. But my question is  program [SAPLZED7] in the dump doesn't exist in the system.I am also forwarding details below replated to dump.Please give some hint how to solve it?? The ABAP/4 Ope

  • SALE/BD64

    hi all, i am doing ALE configuration for two systems SAPD47 & ECC5, in SALE transaction,for both the systems i have created, assigned logical systems, created RFC destination, connection, tested in BD64 transaction,i have created a model view GETSET,

  • HT2534 How does one get reimbursed for an app that has been immediately deleted after download and open?

    I downloaded an app that cost $7.99 and immediately realized that it was not functional the way I understood it to be. I deleted the app and now I wqould like to be reimbursed. How does one go about getting that accomplished? Thanks - George