Hello,
1.We have two R/3 clients 010 and 020. Client 010 will be used for devotement and configuration, and client 020 will be used for unit testing. All the dataSources creation and enchantments will be done in 010 and then tested in client 020.
2.Client 010 will be the only client connected to the transport system.
My question: since the R/3 dataSources and extractors are client independent, when connecting the BI system to R/3, do we have to connect the BI system to both R/3 clients or it is enough to connect to client 020.
I would appreciate it if you share your experience or provide any SAP Notes related to this setup.
Thank you…. ALI

Hi… thank you for your answers. That was my feeling; however, the thing that I am worried about and got me in doubts is the CO-PA extractor. When creating the CO-PA extractor, SAP asks for the client ID to be part of the extractor name (TC: KEB0).  Does this mean that this particular dataSource is client dependent? Is there any other dataSource that requires the client number to be part of it?
Also, if I create this extractor (CO-PA) in client 010, would it be available in client 020? If not, how do we go with such scenario?
If you have more than one R/3 client and using CO-PA dataSources, then please let me know how you are handling it.
Thank you… Ali

Similar Messages

  • SCM and CRM Multiple Clients in one system

    Dear all,
    I want to ask a question regarding Multiple clients in SCM 5 - IDES and CRM 5 -IDES.
    I installed the system and plan to have multiple clients in a system with copying client 800 (IDES) to others.
    I heard opinion that it can't possibly be done because if during the exercise the Administrator Workbench is executed it will search to the source client (800) and probably affect the exercise.
    Would you mind giving me more suggestion about this?
    Thank you.
    Fausto

    Hi Fausto,
    Could you be more specific about what you need to achive?
    You can always creat a new client, logon to the client and do a client copy with TCod SCCL.
    If you logon to other IDES clients then You'ld overwrite the content of the client which have been pre-configured.
    Check the status of the client you need to overwrite from TCod scc4.
    Also to verfiy the status of the target client for TCod se06 -system change option.
    Regards,
    Tolulope

  • Multiple clients to be connected to One BI system

    Hello Experts,
      have to work on a tricky requirement.
      We have already connected one client (say R/3-100) to BI system.We are already running the deltas for the Logistics applications in BI production for this source system clent (100).
    Now the requirement is that we need to connect 4 more clients (say R/3-200,300,400,500) to the existing BI system.We need to take care of the existing delta and INIT for the LO-application for client100.
    My Doubts are :
    1) As datasources are client independent so do we need to activate the datasources (like 2lis*) in all clients one by one? or just activating in one client will make it ?
    2) If we replicate the datasources for new clients in BW side and then want to reload the data from New clients (set-up tables filling and INIT)?would it have an affect on existing deltas (for datasources 2lis*)for existing Source client 100? What shud be the precautions? How we can proceed?Please let us know your opinons plz..
    thank you,
    Balji

    1) As datasources are client independent so do we need to activate the datasources (like 2lis*) in all clients one by one? or just activating in one client will make it ?
    You need to activate the datasources individually for all the client. If you will activate in one client, it will be specific to that only
    ) If we replicate the datasources for new clients in BW side and then want to reload the data from New clients (set-up tables filling and INIT)?would it have an affect on existing deltas (for datasources 2lis*)for existing Source client 100? What shud be the precautions? How we can proceed?Please let us know your opinons plz
    If you will replicate in one client system, it wont affect delta and init from other client.
    One thing you can do, to identify data from different source systems, you can use source system compounding in your infoobjects. Make sure you are not loading data from both the client at the same time. it may lock the DSO and master data.

  • One Business System Per Client

    Going in, I figured I could have multiple business systems tied to a single technical system.  For example, if I have a techical system (SAP R/3) of RD0 110, and I want to have one business system for a vendor price check, another for sending ship notice idocs to a 3rd party server, etc.
    When I go to add a second Business System to RD0 110 in SLD, I get an error that "The selected client already has a business system. Select a different client or system.".
    Where am I going wrong?

    Hi Keith,
    the problem you are running in is that the SLD checks your business system entries against used client and logical system from tech.system. If one is already used in a link to a bus.system SLD does not allow to link the same tech. system to another bus.system.
    But you don´t have unique namespaces for each scenario.
    You will import the SWCV from SLD into Int.Rep..
    Then you can define a range of namespaces in the SWCV object.
    In each namespace you can implement a scenario.
    The SWCV is connected to a bus. system, that s right.
    But the scenario will not only work with one bus.system.
    Usually you will use the SWCV to build up a scenario in Int.Rep. for the sender system providing the scenario with data.
    The bus. systems defined in the SLD  are more relevant in the Int.Directory, when implementing the comm.channels and building up the interface-/sender-/receiver-determinations per scenario.
    If you could connect a tech. system to several business systems what could be the advantage? The tech.system is basis for connecting to SWCVs.
    We had the same question here in the beginning of our project but our result was that the multi bus.system connect to a tech. system would only produce more need of organizing the structure in the SLD.
    We put the focus on naming conventions in the namespaces to separate the different scenarios for the same bus.system as data provider (=sender).
    If more than one system is sending the same date in a business scenario you need to establish that in having a well defined definition (agreements) in the Int. Repository!
    Hope this can help!
    Best regards
    Dirk

  • Multiple Creative sound devices in one system

    -Multiple Creative sound devices in one systemrHello community, I recently tried to get two X-Fi Titanium PCI-Express cards to work in one computer. One card worked well. As soon as i plugged in the second card and booted the system, i got a quite reliable bluescreen SYSTEM_EXIT_OWNED_MUTEX, which indicates improper handling of shared ressources by the driver. I performed extensi've testing on two different machines with both Windows 7 64-Bit and Windows XP 32, freshly installed and patched, latest drivers, no other software or sound hardware present, but the problem persisted. I contacted support an was told that a such a combination is neither tested nor supported by Creative. So now I am stuck with two expensi've cards, that don't work together. Is there any information from Creative which devices will work flawlessly together if combined? For example the X-Fi Go!. It's USB. How many of those will work together in one system? (if more than ) Can I plug in a Soundblaster Play USB device simultaniously? Does Creative test for things like these? And why ist there a "Select Audio Device" option in the Creative Console application if multiple cards don't work?

    Hi Suresh
    Generally it is not possible to activate two industry solution in
    switch framework .(transaction SFW5) ..But we can make the activation
    of industry solution as client dependent and client independent . if we
    make it as client dependent then we can activate different industry solution
    for each client
    To know whether the activation is client dependent or client
    independent you need to check table SFWPARAM for any entries. If it
    does not have any entry then its client independent (repository changes)
    It affects all the clients. Please make entry in table SFWPARAM
    and try !
    I hope this information helps
    Regards
    VV

  • 'SPROXY' - Multiple PI Systems connected to one ECC System for ABAP Proxies

    Dear Experts
    I am currently facing an issue when I want to connected multiple PI instances to one ECC client for
    ABAP Proxy purposes.
    In transaction 'SPROXY', in the Enterprise Service Brower, only one PI instance is shown and accessable.
    Can this setting be changed to allow multiple PI systems in this Enterprise Service Browser?
    Thanks for your ideas.
    Mathias

    Hi,
    Check these replies.
    R/3 connected to multiple XI instances
    'SPROXY' - Multiple PI Systems connected to one ECC System for ABAP Proxies
    Multiple XI Instances
    Multiple XI instances or multiple app server
    Thanks,
    Vijaya.
    Edited by: Vijaya Lakshmi Palla on Jun 4, 2008 11:43 AM

  • Connecting to Multiple ECC systems via one Gateway system(Dynamic System Selection)

    Hi Experts,
    We have multiple ECC systems and one Gateway server. We want to connect to these different ECC systems using one GW system.
    I have created System Aliases for these ECC system in GW system. For a service, i added 2 system aliases.
    Now we are looking for the solution where UI can provide the system alias (it wants to connect) as a parameter while calling oData Service.
    Please help.
    Regards,
    Rohit

    Hi Rohit,
    we have a similar scenario where we have two system aliases for one service. Both aliases point to the same system, but different clients; it should not make a difference though, having different systems. The feature you are looking for is Multiple Origin Composition (MOC).
    There are a couple of things you have to consider:
    in the SEGW the entity to be called has to be marked as addressable
    the URI of the service needs to include the tag for MOC (;mo) --> http://sapgw.domain.org:8000/sap/opu/odata/sap/ZSOME_SERVICE;mo/entityset
    Without the ;mo the call will be routed to your default alias. The ;mo will route the call to both systems. Using MOC will generate an additional key property into your entities --> SAP__ORIGIN. The property is the alias. If you want to route to a specific system you have to provide the SAP__ORIGIN like providing normal key properties in your requests.
    This will look like this:
    <content type="application/xml">
      <m:properties xmlns:m="http://schemas.microsoft.com/ado/2007/08/dataservices/metadata" xmlns:d="http://schemas.microsoft.com/ado/2007/08/dataservices">
        <d:SAP__Origin>SOME_ALIAS</d:SAP__Origin>
        <d:Identifier>SOME_IDENTIFIER</d:Identifier>
        <d:Doublet />
      </m:properties>
    </content>
    The original Entity only consists of the key property "Identifier" and the property "Doublet". "SAP__ORIGN" is added via the ;mo.
    Hope it helped...
    Holger

  • Creating multiple source systems one logical system

    Hi,
    The requirement is to create two source systems using same logical name and different RFC connections to ECC?
    We wanted to do some regular activities using one source system and some drill down activities using different source system.
    I am getting error when I try to create second source system "source system already exist"
    Please advice.
    Thanks.

    Hi,
    I dont think it is possible to create multiple source systems in a sinle logical client. You have to create multiple clients and you can connect to BI system by different RFCs.
    Hope this helps.....
    Regards,
    Suman

  • Can One technical system be assigned to multiple BS system

    Hi All,
    I just need small confirmation, i want to know wether one technical system(ABAP) with same client be assigned to multiple busines system..
    Regards,
    Raj

    Hi ,
    No, you cannot have 2 BS for the same technical system and same client.
    (you can have different BS for every client of a technical system)
    Raghu

  • Multiple IS components activation in one system

    Hi all,
    One curious clarification required: Can we activate multiple IS components (more than one) in one system?. 
    If so, please share your experience and & which are all the components can go together?.
    My understanding is few IS-components can be implemented in 1 system.
    Please share your thought on it.
    Thanks & Regards,
    Suresh

    Hi Suresh
    Generally it is not possible to activate two industry solution in
    switch framework .(transaction SFW5) ..But we can make the activation
    of industry solution as client dependent and client independent . if we
    make it as client dependent then we can activate different industry solution
    for each client
    To know whether the activation is client dependent or client
    independent you need to check table SFWPARAM for any entries. If it
    does not have any entry then its client independent (repository changes)
    It affects all the clients. Please make entry in table SFWPARAM
    and try !
    I hope this information helps
    Regards
    VV

  • From R/3 to CRM create one logical system for CRM client 300.

    Suppose i create one logical system for CRM in R/3 TO CRM scenario for client 300.another user wants to work on jdbc to CRM client 300 for this he wants to create another logical system for client 300 it is not possible,so,it is ok if he assign same logical system when he was working for CRM client 300 when he wants to create business system for CRM in JDBC to CRM.

    Hi,
    Business Systems are te logical system name for a CLient in the SAP.
    These can be reused again for different configuration scnario that you must have created for different interface.
    All you need to do is assing the Business system to your configuration scenario and Communication channel to the same.
    Regards
    Vijaya

  • Can one physical system have multiple logical systems? if yes  why?

    can one physical system have multiple logical systems? if yes  why?
    Regards
    sriman

    Logical system is an ALIAS name for a physical LOCATION. so we may have more than 1 logical system name for a physical location.
    eventhough its allowed,but normally we dont do that.
    you can do this in FILE transaction.
    Regards
    srikanth

  • Is it possible to connect multiple R/3 systems to one APO system?

    Hi,
    Is it possible to connect multiple R/3 systems to one APO system?
    Kind regards,
    Kris De Smedt.

    Hi Kris,
    Yes, you can connect multiple R/3 systems to one APO system. All you need to do is to maintain connection parameters of all the R/3 systems with APO. (i.e. RFC Destinations, logical systems, partner profiles etc.)
    Regards,
    Naveen.

  • IDES and other Clients in one SAP ERP 2005 System

    Hello everybody,
    within a project for my master thesis i have to set up an SAP ERP 2005 System. This system should contain at least three clients. One of them should be the IDES client. Another client should be set up with an existing template. The third client should represent a smal company or at least i should set up some example process from the company (there is no need to map the whole company in the system). These processes should be realized with the SAP standard processes and they should just show how to map easy processes to SAP ERP. Neither the second nor the third client need to run in a productive environment, everything is just for training and testing.
    My main Questions are:
    I've already set up the SAP ERP 2005 System but without IDES. Can I still integrate the IDES Content or do i have to reinstall the whole System with a complete IDES Installation?
    Can I implement the second and third client in the same ERP System (where the IDES client is) or do i need different Systems for it? Even if there is no productive use for the clients we would like to have a Development and a Quality Landscape. Is this possible with the IDES client? Actually I have two fast machines for this purpose - one for quality and one for development.
    I would be very grateful for any hints.
    Thanks a lot.
    Regards,
    Martin

    Hi,
    You can use SAP IDES as Dev and Quailty.There is no diffrence in full sap or IDES .In IDES we have some pree configure Clients and full Ecc we have three client 000,001 and 066.
    So you can use SAP IDES as DEV.
    Your Question :I've already set up the SAP ERP 2005 System but without IDES. Can I still integrate the IDES Content or do i have to reinstall the whole System with a complete IDES Installation?
    Ans : you install diffrent mechine.We do't use any content.Do reinstall
    Thanks
    Pankaj Kalsayan

  • Client transport from one sap system to another one

    When I want to make a client transport from one sap system to another (i.e. the source system is a system without a enhancement package and the destination system is with ehp5) can it be that there come critical conflicts in the modules (like FI, CO or HCM or other ones)?

    Hi Damian,
    It is not recommanded to import TRs from SAP system not at equal level.
    Get both the systems at same level if possible.
    But still if you have senario like this , pls ask to transport owner about changes included to undersatnd criticallity
    Regards,

Maybe you are looking for

  • Controlling amount of space inserted with tab key

    Currently I get a style="margin-left: 40px;" added when I press the tab key. How can I change that amount to an additional 24px for each successive pressing of the tab key?

  • Contacts gmail HELPPPP

    I try to import my gmail contact from my computer but it doesn't work... I synchronize my email acount I receive all my email but I have any contact from my box in my contact book!!! Thanks in advance

  • [SOLVED] ThinkPad T410 Clock Skew

    Hi, I'm seeing (negative) clock skew on my T410 after leaving it disconnected from AC power. The weird thing is that when I check the hardware clock via the BIOS on bootup from battery after AC power's been disconnected for a while, the time is corre

  • Error credit value update

    I have customized a consignment sales order KB with credit control,which is not relevant for billing. After I create a delivery from a KB order and save it.The credit value for sals order is not reduced.And after I post goods issue ,both sale order a

  • Anamorphic project... again...

    hi i have posted a question concerning anamorphic projects some time ago and still havent solved the problem. here is a summary: i have to deliver a project shot on DV pal 3X4 as a 16X9 DVD. i have edited it down as 5X4 sequence and nested it as advi