[nQSError: 12002] Socket communication error at call=recv: (Number=10004)

Can any1 plz help...!
I am unable to start presentation services...! I am currently using windows server 2003 service pack 2. I tried configuring scheduler after which I got the message:
"Windows could'nt start Oracle BI Presentation server on local computer. For more information review the system event log. If this is a non-microsft service, contact the service vendor, and refer to service-specific error code -1."
I am getting these 2 errors:
In nqserver.log shows below error
[nQSError: 12002] Socket communication error at call=recv: (Number=10004) A blocking operation was interrupted by a call to WSACancelBlockingCall.
In nqscheduler.log shows below error
[nQSError: 12002] Socket communication error at call=: (Number=10048) Only one usage of each socket address (protocol/network address/port) is normally permitted.
I have changed scheduler port (in Job manager-->file-->configure options..>schedule-->general tab) to an available open port since 9705 is not available. I also updated port number in instanceconfig.xml file.
Any suggestions would be really appreciated.

have you seen the blog of John about this? http://obiee101.blogspot.com/2008/08/obiee-configuring-configuring-scheduler.html
hope this heps

Similar Messages

  • [nQSError: 12002] Socket communication error at call=recv: (Number=10038)

    Hi, When I try to run any reports in Oracle Answers I am getting the following error:
    Odbc driver returned an error (SQLExecDirectW).
    State: HY000. Code: 10058. NQODBC SQL_STATE: HY000 nQSError: 10058 A general error has occurred.
    nQSError: 12002 Socket communication error at call=recv: (Number=10038) An operation was attempted on something that is not a socket. (HY000)
    When I try to issue a 'Direct Database Request' from Answers, it is working fine and I can see the results. The error is occuring only when I select any columns from the Presentation Catalog and try to run the Adhoc report.
    Please could you help me fix this issue.
    Thanks
    Srikanth

    Hi, When I try to run any reports in Oracle Answers I am getting the following error:
    Odbc driver returned an error (SQLExecDirectW).
    State: HY000. Code: 10058. NQODBC SQL_STATE: HY000 nQSError: 10058 A general error has occurred.
    nQSError: 12002 Socket communication error at call=recv: (Number=10038) An operation was attempted on something that is not a socket. (HY000)
    When I try to issue a 'Direct Database Request' from Answers, it is working fine and I can see the results. The error is occuring only when I select any columns from the Presentation Catalog and try to run the Adhoc report.
    Please could you help me fix this issue.
    Thanks
    Srikanth

  • [nQSError: 12002] Socket communication error at call=(Number=10004, 10048)

    Can any1 plz help...!
    I am unable to start presentation services...! I am currently using windows server 2003 service pack 2. I tried configuring scheduler after which I got the message:
    "Windows could'nt start Oracle BI Presentation server on local computer. For more information review the system event log. If this is a non-microsft service, contact the service vendor, and refer to service-specific error code -1."
    I am getting these 2 errors:
    In nqserver.log shows below error+
    [nQSError: 12002] Socket communication error at call=recv: (Number=10004) A blocking operation was interrupted by a call to WSACancelBlockingCall.
    In nqscheduler.log shows below error_
    [nQSError: 12002] Socket communication error at call=: (Number=10048) Only one usage of each socket address (protocol/network address/port) is normally permitted.
    I have changed scheduler port (in Job manager-->file-->configure options..>schedule-->general tab) to an available open port since 9705 is not available. I also updated port number in instanceconfig.xml file.
    Any suggestions would be really appreciated.

    user12970693 wrote:
    Can any1 plz help...!Gawsh. That's awful.
    I wonder whether people who deal primarily with BI Server might be able to help you better than people who deal primarily with the database?
    http://forums.oracle.com/forums/category.jspa?categoryID=145
    I am unable to start presentation services...! I am currently using windows server 2003 service pack 2. I tried configuring scheduler after which I got the message:
    "Windows could'nt start Oracle BI Presentation server on local computer. For more information review the system event log. If this is a non-microsft service, contact the service vendor, and refer to service-specific error code -1."
    I am getting these 2 errors:
    In nqserver.log shows below error+
    [nQSError: 12002] Socket communication error at call=recv: (Number=10004) A blocking operation was interrupted by a call to WSACancelBlockingCall.
    In nqscheduler.log shows below error_
    [nQSError: 12002] Socket communication error at call=: (Number=10048) Only one usage of each socket address (protocol/network address/port) is normally permitted.
    I have changed scheduler port (in Job manager-->file-->configure options..>schedule-->general tab) to an available open port since 9705 is not available. I also updated port number in instanceconfig.xml file.
    Any suggestions would be really appreciated.On first guess, I'd almost think some anti-virus or firewall is haunting that machine.

  • Request giving Socket communication error at call=recv: error.

    Hi All,
    My requirement goes like this for OBIEE 11G :
    I have two requests(analysis) and I want to show either of them at a given time based on a Dashboard prompt. I have set a Presentation variable {PV} for this Prompt whcih always hays two values A and B.
    My first request is like this :
    Dim 1 Measure 1 ( this should be shown when I select Dashboard Prompt A.
    My second request is:
    Dim 2 Measure 2 ( this should be shown when I select Dashboard Prompt B.
    I have to use the Guided Navigation ( Sectional Condition in 11g)
    When Dashboard Prompt A is selected Section 1 i.e. Request 1 should be shown when Dashboard Prompt B is selected then it should show request 2.
    To achieve this in request 1 I have added a extra filter '@{PV}' is equal to/is in 'A' and in request 2 I have added a extra filter '@{PV}' is equal to/is in 'B' so as when we select B in Prompt the first request should 'No Results' so as I can achieve my Guided Navigation.
    But to my surprise when I select B in the Dashboard Prompt the first request throws an error.
    Error Details
    Error Codes: OPR4ONWY:U9IM8TAC:OI2DL65P
    State: HY000. Code: 10058. [NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred. [nQSError: 12002] Socket communication error at call=recv: (Number=10038) An operation was attempted on something that is not a socket. (HY000)
    Please help me out with this regards as I was able to achieve this functionality easily in 10G OBIEE.
    Regards,
    Bhavik

    Hi,
    Mistakenly my machine got restarted and after that when I tried to start OPMN services,its showing all the processes alive but after that ,while restarting BI services from windows
    its throwing an error of unexpectedly shutting down of services.
    My NQS log says:
    [nQSError: 12010] Communication error connecting to remote end point: address = 192.168.10.209; port = 80.
    [nQSError: 46119] Failed to open HTTP connection to server 192.168.10.209 at port 80.
    I have checked that IP is still same. What is the issue behind it?
    This is very urgent.I have already posted this issues many times but didn't get any response So please help.

  • Socket communication error in OBIEE 10g.

    Hi
    I have below error in nqserver log by which i am unable to connect admin tool and presentation service. I am using OBIEE 10g.
    [nQSError: 12002] Socket communication error at call=recv: (Number=10004) A blocking operation was interrupted by a call to WSACancelBlockingCall
    Please Suggest.

    Hi ,
    Its not about the no. of connection pools u have in ur RPD .Its the maximum number of connections allowed for this connection pool. The default is 10. This value should be determined by the database make and model
    and the configuration of the hardware box on which the database runs as well as the number of concurrent users who require access.
    Ref :
    http://siebel.ittoolbox.com/groups/technical-functional/siebel-analytics-l/oracle-bi-server-stops-automatically-after-some-time-3645235
    Just give it try .

  • Socket communication error

    I am facing a problem in presentation server .
    When i am using AGO date functions i have encountered an error named as.:
    nQS Error:12002 : Socket Communication error at call=recv (number=10054)
    I have goggle'd it but cannot understand thier explanation ...

    Hi,
    Mistakenly my machine got restarted and after that when I tried to start OPMN services,its showing all the processes alive but after that ,while restarting BI services from windows
    its throwing an error of unexpectedly shutting down of services.
    My NQS log says:
    [nQSError: 12010] Communication error connecting to remote end point: address = 192.168.10.209; port = 80.
    [nQSError: 46119] Failed to open HTTP connection to server 192.168.10.209 at port 80.
    I have checked that IP is still same. What is the issue behind it?
    This is very urgent.I have already posted this issues many times but didn't get any response So please help.

  • BI Server Socket communication error

    All,
    OBIEE 10G with Oracle 11 database on Sun solaris.
    BI Server is randomly crashing with following error message:
    Odbc driver returned an error (SQLDriverConnectW).
    State: HY000. Code: 0. [NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred. [nQSError: 12008]
    Unable to connect to port 9703 on machine LOCALHOST. [nQSError: 12010]
    Communication error connecting to remote end point: address = LOCALHOST; port = 9703. [nQSError: 12002]
    Socket communication error at call=: (Number=-1) Unknown error (HY000)
    If you restart, it works fine for 1-2 days. Then again crash happens.
    Any ideas ..?
    ~R

    I've had similar issues due to insufficient memory on HP-UX. Probably best to raise a support log with oracle.

  • How to correct socket communications error 10054: connection reset by peer

    We are running Lookout 5.1 (build 8) reading data through Modbus Ethernet Drivers and we are constantly getting "socket communications error 10054: connection reset by peer" alarms on the server. When I connect to the server file with a client file the client is experiencing communications problems including locking up when editing, trends not showing up, stops updating completely (can only be corrected by restarting server file), and losing symbolic link.
    Does anyone know how to stop this alarm from happening and if this could be the cause of my faulty server-client connection or is this strictly a problem between the server and the ethernet radios in the field?
    Any response would be appreciated.
    Thanks!
    Jason
    Jason Phillips

    DST1,
    All I had to do was increase the receive timeout in each driver's properties until the socket errors disappeared. I have them all set to 30000 msec. Communications have been great on this wireless ethernet system ever since.
    Sorry for not answering sooner - needed to make time to go back and look at the file and then TS Lee came our way!
    Jason Phillips

  • Communication error when calling web service for checkin and checkout files

    Hello,
    I am trying to checkout  and also to checkin files within the DMS via web service. The files are stored in the VAULT (=TRESOR) without the data server parth and DVA computer.
    For checkout:
    Original zum Ändern auschecken
      CALL FUNCTION 'BAPI_DOCUMENT_CHECKOUTMODIFY2'
        EXPORTING
          documenttype    = pi_documenttype
          documentnumber  = pi_documentnumber
          documentpart    = pi_documentpart
          documentversion = pi_documentversion
          documentfile    = lf_documentfiles
          pf_http_dest    = ''
          pf_ftp_dest     = ''
        statusextern    = lf_status
        IMPORTING
          return          = lf_return
          checkedoutfile  = ls_checkedoutfile.
    and for checkin:
    Dokument einchecken
      CALL FUNCTION 'BAPI_DOCUMENT_CHECKIN2'
        EXPORTING
          documenttype    = pi_documenttype
          documentnumber  = pi_documentnumber
          documentpart    = pi_documentpart
          documentversion = pi_documentversion
          hostname        = ''
          statusintern    = ''
       statusextern    = lf_status
          statuslog       = ''
        IMPORTING
          return          = lf_return
        TABLES
          documentfiles   = lt_files.
    But it is not working cause I always get a 'communication error' from the function CV120_FTP_START_REG_SERVER when calling one of these BAPIs via web service:
    IF pf_check_gui = 'X'.
        CLEAR: gf_gui_exist,
               gf_gui_checked.
        CALL FUNCTION 'RFC_PING'
             DESTINATION 'SAPGUI'
             EXCEPTIONS: communication_failure = 1 MESSAGE lf_msg_text
                         system_failure        = 2 MESSAGE lf_msg_text.
        IF sy-subrc = 0.
          gf_gui_exist = 'X'.
        ELSE.
          CLEAR gf_gui_exist.
        ENDIF.
        gf_gui_checked = 'X'.
      ENDIF.
    Afterwards the following function is called where I got the error 'Program no longer started via RFC. No return possible.':
    -> Vault with DVA -> ** Start FTP on the client
      CALL FUNCTION 'SYSTEM_START_REG_SERVER'
           EXPORTING: progname    = 'sapftp'
                      startmode   = ''                          " X
                      exclusiv    = 'Y'
                      waittime    = 500
                      startcomp   = 'C'    " G=gui, C=RFC
                      startpara   = ' '
          IMPORTING: err_code    = lf_errno
                     err_mess    = lf_error_msg
                     destination = pfx_destination.
    Regards
    Jens

    Hi! As mentioned below I had the same problem.
    There are two notes concerning security setting of the SAP Gateway:
    1069911 - GW: Changes to the ACL list of the gateway (reginfo)
    1480644 -  gw/acl_mode versus gw/reg_no_conn_info
    Your basis team should check if the Gateway settings allow external programs to register on the gateway.
    Best regards
    Dominik

  • XSL:Import causing End-Of-Communication error when called in PL/SQL.

    I have master xsl. I am importing another xsl in it. when I use xslTransform in my pl/sql stored procedure I receive end of communication error. I have used "file://" and "http://" both in xsl:import.
    Here's the import lines:
    <xsl:import href="file://D:/temp/Xsd/CommonFunctions.xsl"/>
    or
    <xsl:import href="http://www.v-tek.com/xsl/CommonFunctions.xsl"/>
    I am not sure what causes this error. I tested this in xmlspy and it works well.

    Hi Justin,
    I tried to reproduce your complaint, but wasnt able to. I didnt have a 10104 db to test against though, but I did test against 10105, and 10202, using the following dumb table:
    create table constr_test ( c1 number);
    alter table constr_test add constraint const_1 check (c1 in (1,2,null));
    insert into constr_test values (3);
    commit;
    Frequently a 3113 is the result of an ora-600 or ora-7445 on the database. The fact that it doesnt occur for you on 10.2 db leads me to believe that might be the case here. Have you checked your alert logs?
    Cheers,
    Greg

  • I cannot download photoshop elements. It shows an error 109. Communication error. No phone number that is listed for anything adobe works to where I can call for support.

    I had an error on my Photoshop Elements 12. It would not bring the program up at all. I have tried uninstalling and reinstalling and it will not download. I have now erased the download for the 3rd time and I have tried every phone number for assistance with Adobe. NOT a single number works. There is no online tutorial helps me with anything. I have a new Windows 8 version and when I first bought the computer it took me a while to download. But I did and it worked for about 30 days. 

    Error 10# (any #) : Troubleshoot Adobe Download Assistant  :
    http://helpx.adobe.com/creative-suite/kb/troubleshoot-download-assistant.html

  • Process Chain : Communication error

    Hi, i have DataSource from UDConnect and working good loading data, but when use the InfoPackage in Process Chain then have the Error :
    <b>Communication error: Incoming call is not authorized</b>
    Any idea for help me in detect the problem ?

    Hi any can help in tris problem, only happen in data from UDConnect, the user is BWREMOTE, i test using user by SAP_ALL and not working.
    Any idea the Autorization for UDConnect when using Process Chain ?

  • TNS:internal network communication error at OCI call OCIServerAttach

    hi,
    am using OBIEE 11g, i have made a new repository in obiee and when i done my analysis phase i checked the result and i recived an error :
    State: HY000. Code: 10058. [NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred. [nQSError: 43113] Message returned from OBIS. [nQSError: 17001] Oracle Error code: 12157, message: ORA-12157: TNS:internal network communication error at OCI call OCIServerAttach. [nQSError: 17014] Could not connect to Oracle database. (HY000)
    i made the changes in TNS but nothing happened, any suggestion ??
    thanx..

    Hi Guys,
    I got the same error message. I can see the data in the physical layer. Once i import my repository via weblogic, i can see the subject areas and all its related filed in Analysis section.
    However i cannot view any data for any columns. Error;
    Error Codes: OPR4ONWY:U9IM8TAC:OI2DL65P
    State: HY000. Code: 10058. [NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred. [nQSError: 43113] Message returned from OBIS. [nQSError: 17001] Oracle Error code: 12154, message: ORA-12154: TNS:could not resolve the connect identifier specified at OCI call OCIServerAttach. [nQSError: 17014] Could not connect to Oracle database. (HY000)
      SQL Issued: SELECT 0 s_0, "Invoices"."Customer Name"."ACCOUNT_NAME" s_1 FROM "Invoices" FETCH FIRST 65001 ROWS ONLY

  • System log shows operating system call recv failed(error no.73)

    hi all,
      here i have some doubt in system log please clarify me,
    here in my (sm21)system log files i find more no  of logs for dispatcher and it indicates operating system call recv failed(error no.73)
    system log  Short Text shows:
    Operating system call &5&5&4 failed (error no. &>E5)
    The specified operating system call was returned with an error.
    For communication calls (receive, send, etc) often the cause of errors are network problems.
    It could also be a configuration problem at operating system level. (file cannot be opened, no space in the file system etc.).
    what is means

    Hello,
    Yes, you are right, these kind of problems (OS Error 73) are usually caused by network issues. Error 73 means 'connection reset by peer'. In most cases, this is because the connection was interupted by the communication partner or an active network component between.
    I provide you some recommendations:
    - Check your Network environment. You can use NIPING tool to diagnose it (note 500235), check your MTU stability.
    - Check note 27320 - keep alive and gui_auto_logout profile param
    - Also you can implement note 1002075 for a possible solution
    I hope this helps you.
    Regards,
    Blanca

  • Idoc Processing Error - Communication error calling XI interface

    Hi All, We in the middle of our upgrade from IS-PS-CA 472 to ECC6 and are facing issues processing old Idoc's with status 64 via BD87 the error message says that "Communication error calling XI interface". We have not implemented XI at this point in time.
    Can anyone please advice why this is happen is this something to do the SAP version.
    Please help.
    Rgds
    Saj

    Can you provide the message number.
    Reddy

Maybe you are looking for