Original System incorrect after transporting from BD1 to BQ1 systems

Hi all,
BI 7.0 SP 10
We have having problems with the 'original system' of our DataSources and certain transformations when transporting objects from BI dev system to the BI QA system.
DataTargets are coming through the Transports with the correct 'original system' name but for DataSources and Transformations that are used to map from the DataSource to the DataTargets are incorrect.
We have ensured in our 'Conversion of logical system name' has:
- ID1 -> IQ1
- CD1 -> CQ1
- BD1 -> BQ1 (we were once missing this but this has been added and transported retransported but still it doens't seem to work)
Could it be becauce we accidently activated the DataSources from IQ1 and replicated these in BQ1 and the Transports of the DataSources are not overwriting properly? I would have assumed that the Transports (with overwrite) option would overwrite the existing DataSources and replace it with those from the Dev system.
As for the Transformation, could that be due to the incorrect orginal system setting of the DataSource which in turn is causing issues to the Transformation attached?
Any ideas?
Thanks,
Wiki

Hello,
Goto RSA! -> Tool-> conversion of logicalsystem names
Maintain the entries.
SPRO also we can maintain same entries under transportconnection
hope it helps,
Kishore

Similar Messages

  • Page numbers incorrect after conversion from Excel to pdf

    Page numbers incorrect after conversion from Excel to pdf
    ""This above link (thread:834599) is from a case back in 2011 that claims to solve this problem, but it does not solve this problem. I think that customer only cared about having continuous page numbering, not discrete page numbering per sheet.
    ========================
    I still have this issue in Acrobat XI and MS Office Professional Plus 2010. I keep upgrading to no avail. This regression has resulted in a huge time drain for me. If you fixed it, please explain how I can get my hands on the resolution.
    Previous versions of Excel and Adobe Acrobat enabled flexibility around the "Page #" of "Number of Pages" (Page &[Page] of &[Pages]) token, depending on context and usage. The "# of pages" token could represent EITHER the number of pages in the workbook OR the number of pages in the tab/sheet, depending on how you generated the PDF:
    You could select "Selected Sheets" and then select all or some of the individual sheets in the workbook, and the PDF would honor the discrete numbering of each of the sheets, so the first page of each sheet was p1 and the "# of pages" was the number of pages in the sheet; not the number of pages in the workbook; or
    You could select "Entire Workbook" and the PDF would honor continuous page numbers across all sheets, as a single document.
    Now, it only honors the total number of pages in the workbook, regardless of the method you use to publish to PDF: saving as PDF, printing to PDF, using "createPDF" from Acrobat plugin to Excel's menu ribbon; selecting all sheets, some sheets, or Entire Workbook; automatic First page number or "1" under Page Setup > Page> First page number. (This last option, btw, does restart every sheet at p1, but it hardly makes sense if the total number of pages is still the total number in the workbook instead of the number in the sheet.)
    I spent a lot of time trying each which way that the blog posts recommended and have tried this on multiple versions of Excel and Acrobat now.
    NONE of these time-consuming experiments gave me what I wanted.They all insist that "Page #" of "Number of Pages" (Page &[Page] of &[Pages]) is the total number of pages in the workbook or the total number of pages in the selected sheets combined.
    The numbering are correct in Excel Page Layout.
    The same issue happens when using LibreOffice calc. (Although, I never tested with Libre Office before, so I don't know that it ever worked).
    The workaround now is to create PDF for each spreadsheet one at a time, and then compile them using the Acrobat combine/binder feature. All alternatives are extremely time consuming and tedious. It used to be automatic. This is a major regression that has gone untreated for over a year now, maybe two years.
    My task takes infinitely more time to complete than it did with previous versions of Acrobat. That means that days are added to my project, when the functionality used to enable a quick pdf generation that was ready for review, now I have to do this very manual time-consuming set of steps to generate a draft. As the project has grown and more tabs are added, my pdf-generation task takes that much longer. We require lots of drafts. It used to be easy and fast. Now it is hard and time-consuming.
    In my opinion, the problem is not Excel; it is Acrobat because it was introduced with an upgrade in Acrobat, not an upgrade in Excel. The problem was introduced in Acrobat 9 or 10. Please provide a patch or add-on or something.

    If you are setting up the page numbers in Excel, the resulting PDF would display the the page numbers created in Excel. On Excel 2010 support page, (http://office.microsoft.com/en-us/excel-help/insert-and-remove-page-numbers-on-worksheets- HA010342619.aspx#BM2) is stated the following "tip" which indicates by default Excel 2010 starts numbering each tab with 1. Exel's workaround tip is below - 
    Set a different number for the starting page
    Tip   To number all of the worksheet pages in a workbook sequentially, first add page numbers to all worksheets in a workbook, and then use the following procedure to begin the page number for each worksheet with the appropriate number. For example, if your workbook contains two worksheets that with both be printed as two pages, you would use this procedure to begin the page numbering for the second worksheet with the number 3.
    On the Page Layout tab, in the Page Setup group, click the Dialog Box Launcher next to Page Setup.
    On the Page tab, in the First page number box, type the number that you want to use for the first page.
    Tip   To use the default numbering system, type Auto in the First page number box.
    Also helpful in the same section is the note on viewing page numbers. To see if the page numbering dilemma originates in Excel make sure you are using the Page Layout View see below:
    Hide All
    If you want numbers shown on pages when you print a worksheet  you can insert page numbers in the headers or footers of the worksheet pages. Page numbers that you insert are not displayed on the worksheet in Normal view — they are shown only in Page Layout view and on the printed pages.
    Overall it may be easier not to create the page numbers in Excel but instead create then in Acrobat using the Headers and Footers option in Acrobat.  I hope this helps - it sounds like a frustrating issue you are experiencing.

  • Web Template Changes not visible after transport from Development to Test

    Weu2019ve run into a problem doing web development in BI 7.0 that I suspect someone has seen before and may quickly be able to point us in the correct direction.  Changes that are made to web templates in the Web Application Designer are correctly transported from development to the test environment, but we are still seeing the old version of the template when the report is executed.  We are able to see the web template changes in the Web Application Designer in the test environment.  We believe this is a caching issue and have cleared the query cache and the HTTP cache in SMICM.  Unfortunately, this has not resolved the issue.  Can you suggest another approach to resolve this issue?

    Not sure what you mean by browser cache.  We have deleted history, cookies, and all temporary Internet files.  The issue isn't limited to a single user, but exists for all users.  Through extensive testing we have established that you are able to see the web template changes in test in the WAD(Web Application Designer) after they have been transported from development, but can only view the changes when the web template is run for the first time.  Changes to existing templates can be seen in the WAD in test, but are not seen when the report is run.  The old version of the template appears to held in cache somewhere, but we haven't been able to find it and clear it.

  • System Time is Incorrect After Waking From Hibernation

    If my MBA runs out of battery when its asleep, after coming back to life, the system time is wrong. The time is correct when it comes back from normal sleep.
    Message was edited by: DrFooMod2 -- Corrected OS version

    Hi
    Same here. On PC boards the clock is usually buffered by a small battery.
    Maybe there is no battery in the MBA. But the clock is synchronized over the internet by asking a time server. So you dont need to do it manually
    HTH
    Enno
    DrFooMod2 wrote:
    If my MBA runs out of battery when its asleep, after coming back to life, the system time is wrong. The time is correct when it comes back from normal sleep.
    Message was edited by: DrFooMod2 -- Corrected OS version

  • "No service for system..." after transporting from dev to prod

    Hi,
    again i have a problem like some other guys also had. I already checked several postings concerning this issue!
    We transported dev-objects to prod, also ID-object like Business Systems.
    The sender side now changed their communication for sending IDoc's to our Prod-XI. While sending IDoc's form Prod R/3 they get "no service for system SAPPSI, client010.." etc.
    I already checked:
    1. idx1 port is SAPPSI pointing to right destination PSI
    2. idx2 all necessary Metadata are loaded
    3. checked adapter specific identifiers in ID and also reloaded them with no change!
    4. in receiver IDoc CC i added RFC-Dest: PSI and Port is SAPPSI
    5. did a cache refresh!
    I need to let you know that we are using one SLD and already communicated with the sender-prod r/3 -system to SAP XI -DEV.
    can someone please help us?! we have no clue what might be wrong!!
    br

    Well i have some strange thoughts:
    when the idoc is send in sender-system the values on sender informations are:
    Port: SAPPSI
    Partner number: PSICLNT010
    Type: LS
    The error we receive is:
    no service for system SAPPSI, client 010 in Integration Directory
    Shouldn't there be the Partner-Number like PSICLNT010?!
    Can someone confirm and tell me if i am right?!
    br

  • BADI not found in QA System after transporting from DEV system

    Hi,
    I had created a new implementation ZHR_IN_CALC_PTX_AMT to the BADI: HR_IN_CALC_PTX_AMT in the DEV system with Request ID. But when i had transported that request, i am not able to find that BADI implementation in SE18 and SE19 respectively in Quality system.
    Please suggest me on this, as this is urgent.
    Regards.
    Ravi

    Hi,
    Can you pls repeat the BADI Definition name? I couldn't find HR_IN_CALC_PTX_AMT in SAP versions 4.7, 5.0 and 6.0. Which is the version you use for development?
    Regards,
    Renjith Michael.

  • Move Transfer rules from BD1 to BQ1

    Dear Friends,
    How can we Create and Move the Transfer rules from Development system(BD1) to Quality System( BQ1)
    Regards
    Ramana

    Hi Ramana
    Follow these steps to collect your objects in a transport.
    1. In RSA1, you have a tab "Transport Connection" on the left pane. Click on it and you will see various options, for Ex, InfoObjects, DataSources, DTPu2019s etc.
    2. Click on the InfoObjects and expand it, there you will see "Select Objects" option. Double click it and then a windows pops up. You need to put the object names and say Transfer selections.
    3. All you objects will be collected on the right pane. It might collect other related objects like DSO (if those objects are being used in that), the corresponding DataSource, DTPu2019s etc. If you donu2019t need them deselect them and then click on the "Truck" icon on the top.
    4. It will ask for a transport number, there you can click on the "NEW" icon and it will create a new transport for you. All your objects will be collected in that TR.
    To Move the TR
    1. Go to SE10 and select your TR (one u create above).
    2. Expand it and click on the Sub-TR. Then click on the Truck icon on the top to release the TR.
    3. Similarly release the actual TR by clicking on the Truck icon.
    4. Go to T-code STMS and move this TR to the desired environment.
    Thanks in SDN points
    Regards,
    Ramana Paruchuri

  • Test System (BQ1) Objects showing up wrong Source System after Transport.

    Hi Experts,
    We are working on IS-U BI7.0 Project. We have finished with our Development and have transported the DataSources, Transformations and DTPs from Development (BD1) into Test (BQ1) Systems.
    We have entered values in the Conversion of Logical Source Systems correctly.
    When we select the DataSource and Click Object Directory Entry from the Extras Menu, we found that the Original Source System is defined as BQ1 instead of BD1 (Development System), which is where the Object is getting Transported from.
    We have implemented an SAP Note:1008633 (Incorrect Source System after Transport (RSTRAN 514) but couldn't resolve the issue.
    We basically want all the Objects in the BQ1 (Test System) showing the Original Source System as BD1 (Development System) but only the DataSources and it's connected Transformations and DTPs are originating from the BQ1 (Test) System itself (The Transformations when Transported from BD1 to BQ1 are Transported with a different Technical Name which is very strange).
    Had anyone faced similar problem and if so, what was the effective solution implemented.
    Any help in this regard is very much appreciated.
    Thanks in Advance.
    Best Regards,
    Chandu.

    It is resolved by our Basis.
    Thanks,
    Chandu

  • Ended with return code: === 8 === while doing transports from Dev to Test

    Hi Experts,
    We are doing transports from BD1 to BQ1 and getting this error message.
    Could anyone please let me know why and what would be the solution for the following error message:
    Execution of programs after import (XPRA)
    Transport request   : BD1K900065
    System              : BQ1
    tp path             : tp
    Version and release: 370.00.09 700
    Execution of programs after import (XPRA)
    End date and time : 20070803133308
    Ended with return code:  ===> 8 <===
    Thanks in advance.
    Best Regards,
    Chandu.

    Raymonds,
    There is huge list of errors coming up. Some of them are as below:
    Navigation attribute 0SALESORG is missing in characteristic 0PLANT
    Navigation attribute 0SALES_DIST is missing in characteristic 0PLANT
    Characteristic 0RT_LOCATIO: Referenced characteristic 0PLANT not (actively) available
    Attribute 0INT_CUST from characteristic 0SALESORG not (actively) available
    Attribute 0CRM_MKTELM from characteristic 0UCCONTRACT not (actively) available
    Attribute 0CRM_MKTELM from characteristic 0UCCONTRACT not (actively) available
    Hierarchy characteristic 0BPARTNER of characteristic 0UCCONTRACT is not active
    Characteristic 0UCOUTLCONT: Referenced characteristic 0UCCONTRACT not (actively) available
    Characteristic 0UCOUTLCONT: Referenced characteristic 0UCCONTRACT not (actively) available
    Thanks in advance.
    Best Regards,
    Chandu.

  • Change of technical name after transport

    I found some of the technical names of dtp's are changed after transport from development system to quality and not all dtps names are changed..
    Is there any specific reason that some dtps technical names are changed after transport and some not changed?
    And there are any more proceess type that change when they are transported ?
    Thanks
    vamsi

    Hai thats correct techincal name of DTP's change after successful transport from dev - quality or any instance for that matter .Its quiet normal in BI 7 infact a bug which we too found intially .
    Goodday.
    Edited by: SapBuddy on Oct 7, 2008 7:19 PM

  • BPS - Regenerate a BSP after transport

    Hi all,
    We are currently experiencing the problem that after transport from D to Q, our BSP's are not being regenerated automatically.
    So, although the correct configuration (in the WIB) is to be found in Q after transport, the ABAP workbench view of the same BSP is still reflecting the pre-transport configuration.
    Any ideas please....?
    Thanks,
    Rael

    Hi Alessandro,
    Whenever I generate the BSP in the WIB(web interface builder) it prompts for a transport.
    When you say the BPS transport manager, do you mean the transport manager found in tx code BPS0....? I don't see the possibility to transport web interfaces from this transport manager...?
    Thanks,
    Rael

  • Transport from one System to another

    Hello,
    I want to transport from one XI-System to another XI-System. I tried to make a import from the SLD but that doesn´t work, why? When i make a file transport and make changes of the transported Software-Component will there be the changes of the original Objekts in the sld?
    Thanks in advance,
    Frank

    Hi all,
    In the case when we have multiple SLD's for Dev/QA/Prod ..There has been a case of manual business system creation in QA for some scenarios. Now I need to move a new scenario into QA and I would like to do an SLD export from Dev to QA..
    1.Will this overwrite the existing business systems in QA?I have re-created the QA business sytems  in DEV with a QA target..
    2. I am taking a Backup of QA SLD before doing this.
    Any advise..
    -Teresa

  • Wrong conversion of source system after transport

    Hello,
    We ve got a a transport problem in our 3-3 Landscape. Connections for extraction are only between same systems ( f.e. dev to dev)
    BI Dev         BI Test       BI Prod
    R3 Dev         R3 Test      R3 Prod
    The conversion of source systems is on the BI test:
    BI Dev becomes BI Test
    R3 Dev becomes R3 Test
    The conversion of source systems is on the BI Prod:
    BI Test becomes BI Prod
    R3 Test becomes R3 Prod.
    With this it tells me the after transport (BI Test to BI Prod) of objects with source system assignement that the R3 Dev System is not known.
    The transport before from the BI Dev to BI Test worked well without any problems.
    We`ve got the BI Test and the BI DEV on the same host.
    Has anybody got an idea what is wrong?
    Thank you folks.

    It must be R3D (dev system)
    Something like following should be maintained in production
    R3DCLNT100 <u>R3PCLNT100</u> [Assuming R3PCLNT100 is your production system]
    Don't forget to assign points,
    -jayant

  • Last changed date different between two systems after transport

    Hi, first of all, I am not from basis background and just want to make sure whether is this something correct or not.
    I found that the "Last changed date" and "username" are not same between the original system and the target system. Is this something configurable?
    And the "username" field is totally empty. However, the program code's version is identical in both systems.

    I think I misunderstood your question.  You are referring to the system Transports not the connections between systems.  If the Transports are not transferring all the contents, you really should talk to your basis folks and tell them which items are not being reproduced correctly.
    Regards,
    Mike

  • System clock fails to update after waking from sleep

    I've noticed that my new PowerMac G5 Dual-Core 2GHz (running Mac OS X 10.4.3) doesn't update its system clock to the current time after waking from sleep.
    When I put it to sleep and then wake it some time later, the Clock in the upper right-hand corner doesn't update to the current time. It still ticks on (second for second) but remains out of sync.
    Opening the Date & Time preferences pane will restore the time to the correct setting.
    This problem only occurs with sleep and then wake-from-sleep. It doesn't happen when I shut down the machine and then restart it.
    Does anybody know if I've got a malfunctioning machine? It's only 1 day old...
    Or better still, how do I solve this problem?
    PowerMac G5 Dual-Core 2GHz   Mac OS X (10.4.3)  

    No, my Mac is not having trouble contacting the time server. I checked the console log and found no messages related to this.
    I am on a broadband always-on connection (recently switched from DSL to cable modem, and the problem occurred under both connections). However, my original post states that the computer loses time only when it is asleep, and I didn't think that my computer could contact the time server when it is asleep. It also loses time when it is off, which I neglected to mention previously. Am I mistaken in thinking that the computer communicates over the network only when it is awake? Since it keeps accurate time when awake (once I've reset it by opening the Date & Time control panel), it seems to me like it IS communicating with the time server without issue.
    [And I apologize for misinterpreting your question as a suggestion. I was trying to be polite by thanking you for taking an interest in my issue. I'll watch my semantics more carefully next time.]
    Cheers,
    Katy
    G5/dual core 2.3 Ghz   Mac OS X (10.4.4)   2.5G RAM

Maybe you are looking for