Posting Error In F-53

Dear All,
When i do outgoing payment in F-53 Forgien currency  USD the system is showing following errors
Posting is only possible with a zero balance; correct document & Incorrect automatic postings are cancelled. And i have checked OBA1 - Forgien currency.
The entry like
Vendor A/c          916 USD   Dr
   To Bank USD     916     Cr
In local currency
SBI  USD                      42,594.00-
Vendor A/c                  41,430.68
Ls ex rt fln                   1,163.32
But am not able  to post the document.
Please give your valuable input for the above issues.
Thanks & Regards,
Venkat.

Dear Venkat,
When posting a document in foreign currency there can be rounding
differences. Mayyou please make sure if Exchange rate
differences accounts were properly defined in the IMG.  Please check the following IMG path:
Outgoing Payments Global Settings   >Define Accounts for Exchange
Rate Differences, transaction OB09.  Furthermore, customizing in OBA1 might
need to be reviewed. In addition, please verify currency and specified
G/L accounts in customizing table T030H.
Or you can set the flag 'no forex rate diff when clearing in LC' in
transaction OBY6 for the company code and do the clearing in the local
currency.
Please check if the invoice document was posted with parallel currency that now are deactivated.
If Yes, please refer to the note 89531.
I hope this can help You.
Mauri

Similar Messages

  • How to catch Posting error in File to IDoc Scenario?

    I have successfully completed File to IDoc Scenario. Now I am interested in catching posting error. i.e., if mapping goes well and when IDoc is being sent to Recipient system then if any posting error is encountered, then a mail should go to a recipient.
    Can anybody suggest the solution.
    Regards,
    Suraj Kumar

    Hi Suraj,
    this can be done by triggerring an alert to the recipient.chk out these links to trigger a alert
    /people/sap.user72/blog/2005/01/14/alert-management--improving-monitoring-of-your-landscape
    /people/sap.user72/blog/2005/01/14/alert-management--improving-monitoring-of-your-landscape
    regards
    jithesh

  • GR/IR Posting Error CKMLGRIR025 - Purchase Order History Inconsistent

    Hi Everyone.
    We currently have a posting in our GRIR for a Feright Condition Value against a Purchase Order which gets the above error when trying to post in MR11.
    The Diagnosis of the error reads:
    "The purchase order history contains differences between the goods receipt and invoice receipts/Account maintenance for the order item in the field Difference Quantitiy (= 43.804 TO) and Difference Value (= -342.77)
    The purchase order history for this tiem is inconsistent"
    When looking at this Freight Condition information in the Purchase Order I can not see why this item has resulted in this error in MR11.
    Has anyone else seen this error come through in their system, and do you have any ideas on how to fix this.
    Thanks
    Hayley

    We are experiencing the same issue with the GRIR Posting Error CKMLGRIR025 - puchase order history inconsistent.  The actual message that we receive is Puchase Order history already inconsistent -->Quantity 1.00 EA Value 0.65-USD.
    We reviewed SAP Note 708649 which also recommends using transaction MIRO with the corresponding default quantity and value o.  However, we are not able to enter an Invoice for the "default qty & value 0", as SAP gives me error message M8278 "You are not allowed to have zero lines" (just like Haley commented).  In reviewing this thread, I did not find the solution to the error message M8278 "You are not allowed to have zero lines" .  Could someone help me understand?
    Thank you!

  • Fi posting error

    Hi SAP gurus,
                        I am facing posting error fi_tax_chk_pricing_data
                       error code 13 builder tax2.
                     plz help me

    hi
    u get this error when u have not specified the county while creating the company code go to  OX02 and give country for the company code. this solves your problem
    rgds
    sree

  • MR11 GR/IR Posting Error - PO History Inconsistent - error message M8278

    Dear experts,
    We have the problem as described in SAP note 708649. Error CKMLGRIR025 - Purchase Order History Inconsistent  
    This has also been described in this thread
    Re: GR/IR Posting Error CKMLGRIR025 - Purchase Order History Inconsistent
    We also have the issue on posting an invoice "default qty & value 0" in MIRO, receiving error M8278 "You are not allowed to have zero lines".
    However, so far we are not able to correct this eg do not know how to continue to clear the GR/IR
    Any help or hints on this matter would be appreciated

    Hi,
    please note that the error message M8 278 is only issued if there is                            
    zero amount in ALL document lines.                                                                               
    This means that you can post MM-documents with zero lines. But only if                          
    there are other lines with amount > 0. The reason for this system                               
    behaviour is, that every time a MM-Invoice is posted, an FI-Document is                         
    created. In FI-Documents it isn't allowed to have zero lines.                                   
    So if you have an MM-Document with only zero lines, the Fi-document                             
    can't be created and the error message is issued.                                               
    I hope I could help you further
    Best regards
    Erika

  • PO posting error

    guys,
    i get this posting error when i try to create a purchase order.... please some one help on this??
    tnx
    wiz
    Posting only possible in periods 2009/09 and 2009/08 in company code 2000
    Message no. M7053
    Diagnosis
    The posting date entered is not within one of the permitted posting periods (current period/previous period).
    This can be due to one of two reasons:
    The correct current period has not been set in the system.
    For the system, the first of the entered periods is the current period. At the beginning of a new period, your systems administrator must change the current period in the material master record, using the function "Shift periods". This has not yet been done.
    You have entered a wrong date in the field "Posting date".
    Procedure
    Check the posting date and correct it if necessary. If your input is correct, inform your systems administrator that the "period shifting" (period-end closing) process has not yet been completed. Copied from M8022

    Hi,
    The problem was due to posting period is not open for posting yet.
    I believe you are trying to create PO for Oct 2009. But your posting period was open for Sept 2009 and Aug 2009.
    Go to tcode MMRV to check for company code 2000, current period  09 2009, previous period 08 2009.
    Go to tcode MMPV, enter the company code 2000, period 10 and fiscal year 2009, select "Check and close period" and execute.
    Go to tcode MMRV to check again for company code 2000, current period should be 10 2009, previous period 09 2009.
    You should be able to create a PO by now. If you still fail to do so, please contact your FI to open FI period via tcode OB52.
    Hope it helps.
    Regards,
    JT

  • General Ledger Posting Error (GLT2 051) No accounting transaction variant

    Hello SAP Gurus-
    When testing lockbox in FLB2, I received the following error message:
    General Ledger Posting Error (GLT2 051) No accounting transaction variant assigned to FB01/  /LB
    We are on ECC 6.0
    I created a new Document Type LB
    I created a new G/L account for Lockbox clearing and AR
    How do I fix this?
    Thank you!

    Hi,
    Assign a transaction variant for the document type you created in  Transaction code GSP_VZ3. Also, make sure that the GL accounts affected are assigned with item categories in GSP_LZ2.
    Thanks
    Aravind

  • POST errors need help

    Can any one tell me what the POST error of 2 beeps pause 1 beep is realted to? The system begins to boot flashes video, video shuts off, cmos info flashes shuts off and give post error.

    Use just one stick of RAM in a green slot. Reset the Bios and be sure the machine is not pluged in when you do those things.
    Remove all unneeded hardware so that you don't have stuff in the box when you try to boot that is not needed to post.
    Find out which Bios you have when the screen first comes up.
    You need to know which CPU core you have. If it is a Clwhammer, Newcastle or Winchester then you need Bios version 3.3 If it is a San Diego, Venice or X2 then you need Bios version 9.1.
    Now that you have a system with the correct Bios you can then install your RAM in slots 2 and 4. You should then get a post into dual channel mode.
    Set in Bios first - Optimized Defaults. Make sure that you do not skip this step.
    Now setup the Bios to match the gear in the box. No overclockinmg as yet.
    Now get Windows cleanly installed with any drivers you may need.
    Now you are ready to install those other items you have in your hot little hands. One at a time.

  • (C1) Initialize POST Error Manager (PEM)

    Hello,
    My hardware diagnostic card gives the following error: (C1) Initialize POST Error Manager (PEM). My bios just starts well and gives no error messages.
    I can go to the bios as usually and my computer works normally (at the moment), but QuickTech also gives some error messages:
    - BIOS Buffer overrun check
    - SMBus Host detection
    Maybe that these errors also have to do with it?
    When I try to search with Google I only get some manuals where these error codes are listed, but no more explanations and possible solutions.
    Can somebody please tell me what this problem is all about and how to fix it?
    I have a MSI 6533 bord.

    Hi,
    No, unfortunately not. I posted this question in a lot of different forums, but no one seems to know what's exactly wrong and how to fix it.
    I keep searching, and when I find some answers / solutions, I'll post it here. Can you also please keep me informed if you know some more?

  • Fi posting error due to fiscal period error 1

    HI SAP GURUS,
    I am trying to post TR6 Challan in todays date & getting following message-
    Fi posting error due to fiscal period error 1
    Message no. 8I216
    Diagnosis
    Attempt to post the document in a period outside the current Fiscal
    period  setup.
    Procedure
    Change the posting date  or  Change the fiscal  period prior to posting
    the  transaction under consideration.
    please help me to resolve the issue.
    CHEERS

    HI
    This error is due to Posting period is not open in FI check the posting period is opened for all the accounts in OB52 then post the entries
    hope it will be usefull

  • MSI X79-GD65(8D) gives a posting error 63 Late CPU Initialize

    Hey Guys.
    I have recently purchased new hardware.
    MSI X79-GD65(8D) Motherboard
    Intel i7 3820 CPU
    4 X Corsair Vengeance 4GB DDR3-1600 RAM
    MSI GTX660Ti Power edition GPU
    Corsair 750W Professional series PSU
    Corsair H80 CPU Cooler
    I haven't overclocked ht e mobo, but on cold boot, the mobo doesn't initialize, gives a post error 63, refered to the mobo manual, it says it means late CPU initialize. Checked the BIOS, running version 1.7 and according to MSI download site for the CPU support list.
    The memory is in quad channel as it shows in a diagram in the mobo manual. If I switch the pc off, and back on, it initializes and boots, the pc runs stable, it can run 48 hours no hassle, passes burn in tests to, just the first cold boot doesn't initialize.
    Any ideas for what to look at would be great.
    Thank you.

    A little hint for you: Don't try any of the .1B betas as they run horrible. I had to remove the latest .1B3 as it bricked the board and had to be recovered.
    1.18 B7 is still the best bios to use:
    Quote from: flobelix on 17-November-12, 00:49:07
    I'd suggest the later Bios 1.18 B7 which I'm also using with the i7-3820 (https://forum-en.msi.com/index.php?topic=154186.msg1192427#msg1192427)

  • Thru Collective conf goods posting error neds to be avoided going to COGI

    Dear,
    While doing collective confirmation along with Goods posting, If the stock is deficit then error posting generating in COGI. We need to stop error posting in IW42 itself not allowing to post error in COGI. Customisation is already done for Termination for Incorrect Goods Movement.

    Dear,
    When you post via the collective entry as well as when updating dependent goods movements of the collective order processing, no error handling is provided in Standard SAP. If you do this with IW41 it will work for you. If you set In Customizing of the confirmation (Transaction OPK4), I set error handling in case there are any incorrect goods movements.
    Transactions IW41 and IW42 are both considered to be completely separate transactions. In the individual completion confirmation, a linkage occurs between goods movement and completion confirmation that you cannot find in the overall completion confirmation.
    For this reason, the function  "Incorrect good movement"' leads to a termination in Transaction IW41 and not in Transaction IW42.
    Work around for it schedule the program CORUAFFW in background  using SM36 on hourly basis so it will clear the COGI post processing error.
    Hope it will help you.
    Regards,
    R.Brahmankar

  • Post error: Primary IDE 80 No Conductor cable

    I need to know what this error message means and how it is corrected:
    During the Post, the BIOS recognizes my hard drive then I see this message
    Primary IDE 80 No Conductor Cable
    I have just finished installing a Maxtor Diamond 7200 40GB hard drive.  I have also updated my BIOS to 3.50.
    I can't find this message in any trouble-shooting manuals.
    Any help is appreciated.

    i have a KT4 Ultra (plain) and i'm getting the same post error, i did as said by purchasing cables that specifically said they were 80 conductor and i am still receiving the message. on to of this i am also getting a post beep saying that there is a memory refresh error. also, i'm not sure if any of this is related, but i am also getting bluescreen errors during the installation of windows xp. the two errors i have received thus far are, IRQ_NOT_LESS_OR_EQUAL 0X0000000A (0X00000060, 0X00000002, 0X00000000, 0X807CE5EA) and CDFS_FILE_SYSTEM 0X00000026 (0X000401F4, 0XF80CB900, 0XF80CB600, 0XF8696021O).
    my sys config is as follows:
    420 watt psu
    amd athlon xp 2000+ @ 133
    512 ddr pc2700 @ 333
    ibm  deskstar 40gb hd primary master
    creative 12x dvd rom primary slave
    sony dru-500a dvd ±r/±rw secondary master
    seagate 2gb hd secondary slave
    3d prophet 3 video card
    sound blaster live 5.1 platinum sound card
    as of now my only conclusion is a faulty main board.

  • K9AGM2 Mobo PS2 Mouse POST Error Message

    Bios AMI v02.61
    Recently the USB mouse connected to the system died and I had to  temporarily attach a PS2 mouse to install a replacement and all this works fine. However when I turn on the PC now I get a POST error message "PS2 mouse not found press F1 to continue". How can I I get rid of this tiny annoyance? I have searched the bios options and reset the CMOS to no avail.
    TIA,
    Colin

    Quote from: corkyboy on 26-November-07, 16:31:31
    I read the Moan Guide but could not find any references that were helpful. As to the origin of the board, it was purchased from a retailer here in Australia and the manual describes it as a K9AGM2(MS-7327 SERIES) and has the AMD 690G/690V chipset. Have to say in all respects it is a great little mobo.
    Colin
    "I read the Moan Guide but could not find any references that were helpful."
    We need Full details about your system, Moan Guide shows what we need. Example in my signature.
    Please provide full details about your system. ID board with Everest:
    http://www.lavalys.com:8081/beta/everestultimate_build_1180_y1obfjxk7ls.zip
    or look here how to ID board: https://forum-en.msi.com/index.php?topic=107777.msg798546#msg798546

  • Help: POST error 0167 after upgrade

    Hi all,
    I have a Thinkcentre A55 (9641A45) and I am trying to update it.
    I have replaced the original Core 2 Duo E4300 (1.8 Ghz) CPU with a newer E4700 (2.6 Ghz) cpu. The Intel 946GZ chipset is compatible so this shouldn't be a problem.
    Half-way through the startup I got the "POST Error 0167: no processor BIOS found" message. after a few seconds the startup continues with no other errors.
    However, when I check the processor it is running permanently at half speed (1.3 Ghz).
    I try going into the BIOS (I have the latest that Lenovo has provided) to see the CPU settings but the advanced settings are hidden.
    Anyone have any ideas as to why this is happening? Any suggestions on how to fix this?

    Just a thought, have you tried to reset the bios? Take out the battery on the motherboard for about 15 mins and put it back in then see if  you can access the BIOS settings. Make sure you have a copy of what settings you have in the BIOS though.

  • K9AGM3 Mobo PS2 Mouse POST Error Message

    I connected a wireless USB combo mouse+keyboard and every time I turn on the PC, I get a POST error message:
    "PS2 mouse not found. Press F1 to continue"
    I tried to update BIOS using the Live update Series but it informed me that I had the lattest version
    Also, there is no halt on errors option in BIOS menu
    How can I get rid of this annoyance?

    Quote from: dpanteli on 12-January-08, 18:17:06
    I connected a wireless USB combo mouse+keyboard and every time I turn on the PC, I get a POST error message:
    "PS2 mouse not found. Press F1 to continue"
    I tried to update BIOS using the Live update Series but it informed me that I had the lattest version
    Also, there is no halt on errors option in BIOS menu
    How can I get rid of this annoyance?
    I have K9AGM3-FIH board, and it's suposed to be HTPC board, and what I get, I can't normally run my home theater without keyboard and mouse , because of "Press F1 to continue". How can I press F1 with remote  ??? Every cheapest MB has halt on error option in bios. C'mon MSI, make a proper bios for this board.

Maybe you are looking for