PPCI and PM01

Hi gurus-
My understanding about the TC's PPCI and PM01 is as follows:
PPCI- Transaction code for creating custom infotypes in OM.
PM01- Transaction code for creating custom infotypes in PA.
Is that correct or am I missing something??
Thanks.
Ramesh.

Hi Ananath you care missing something... you can't create directly OM infotypes through PPCI, before you have to create the table structre in SE11, then only it is possible to create OM Inofyptes through PPCI.
Thanks
Suri

Similar Messages

  • Photograph and PM01

    How to upload the Photograph of the applicant using
        OOAD transaction?
    I need step by step procedure if possible.
    Give me any example for when we create a custom infotype
    using PM01?
          Kindly and quickly do favour to me friends.
    Mark:5

    For the picture load...This site gives step-by-step for both older and newer versions....enjoy!
    for 4.7 and up...
    http://www.sd-solutions.com/documents/SDS_Employee_Photos_v4.7.html
    for 4.6....
    http://www.sd-solutions.com/documents/SDS_Employee_Photos_v4.6.html
    As for custom infotype via PM01....
    step-by-step with pictures..
    http://www.sapdevelopment.co.uk/hr/hr_infotypes2.htm
    step-by-step info...
    http://www.sapfans.com/forums/viewtopic.php?t=142405&view=previous&sid=41b52c000838ea9f0656ad1874291abb
    more info on PM01...
    1) Go to Transaction PM01. 2) Enter the custom Infotype number which you want to create (Should be a 4 digit number, start with 9). 3) Select the ‘Employee Infotype’ radio button. 4) Select the ‘PS Structure Infotype’. 5) Click on Create… A separate table maintenance window appears… 6) Create a PS structure with all the fields you want on the Infotype 7) Save and Activate the PS structure 8) Go back to the initial screen of PM01. 9) Click on ‘All’ push button. It takes a few moments. 10) Click on ‘Technical Characteristics’. Infotype list screen appears 11) Click on ‘Change’(pencil) button 12) Select your Infotype and click on ‘Detail’ (magnifying glass) button 13) Give ‘T591A’ as subtype table 14) Give ‘T591S’ as subtype txt tab 15) Give your subtype field as subtype field 16) Save and come back to PM01 initial screen 17) Click on ‘Infotype Characteristics’ … Infotype list screen appears 18) Click on ‘Change’ (pencil) button 19) Click on ‘New Entries’ 20) Enter your Infotype number and short text 21) Here we have to set different Infotype Characteristics as per the requirement. (Better open another session with some standard Infotype’s infotype characteristics screen and use as the reference to fill yours) 22) Save your entries. 23) Now the Infotype is created and ready to use. 24) If you want to change the layout of the Infotype as per your requirement… 25) In the PM01 initial screen…Select ‘Screen’ radio button and give 2000 as the screen name, then click on edit. 26) In the next screen.. Select ‘Layout Editor’ and click ‘Change’. 27) Screen default layout appears…here you can design/modify the screen..change the attributes of the fields..etc. 28) Save and activate. (Don’t forget to ‘Activate at every level)

  • Enhancement Adding a new field to a infotype

    We are implementing E-Recruiting and trying to a new field to a existing infotype 5107.  On the E-Recruiting page there are three frield that already exist.  Country, State and City these field also in infotype 5107 too.  Country and State both are dropdown box.   I have to set the default value for Country to 'USA' and State to 'AZ' where can i set this?   The new field will display location "county" which the user will be able to select multiple locations.  I know i would have to go PM01 to add the new field to the infotype 5107.  But i'm missing the third that will allow me to do this.  There's IT, IT Version, IT (i don't have this on my SAP Gui).  I'm not sure what to do next after I created this new field.  how can put this new field this the E-recruiting webpage?

    Matthew,
    You can enhance your infotype 5107 from tcode 'PPCI' not 'PM01'.
    Check out this Custom Infotype Creation in ORG Management
    Regards,
    Ahmad

  • Add IT0006 custom fields for segment definition E1P0006 basic type HRMD_A06

    Hello!  I am am trying to determine how to bring in our custom fields from IT0006 into our IDOC's for message type HRMD_A basic type HRMD_A06 without performing a custom SAP modification.  I was able to create a new segement definition called Z1P0006 and replace the SAP standard E1P0006 IDOC segment defintion in table T777D for infotyp 0006 to Z1P0006.  However, I receive a message that I must not maintain this IDOC segment manually and instead you must maintain infotypes and their individual elements by using the transactions for processing infotypes: PPCI or PM01 (Infotype copy transaction for personnel administration). 
    Does anyone know of a way to bring in the new custom infotype fields from i.e. reimport the table structure for IT0006 into the segment definition without a custom SAP modificaiton?  I would really appreciate any help on this topic!
    Thanks!
    Holly

    unfortunately, the standard do not provide the infotypes for the HR-TM (Time Management), that
    are between the structures i must send in the other system sap.
    Ok, I have never delt with Time data in HRMD_A. Probably this is the case then
    Ok,now i've checked the filter in BD64 and the tables BDCP2, CDHDR and CDPOS but it seems
    all correct!!
    By checking Filters I mean that confirm if you have added Time Infotypes there (just
    making sure). If data is appearing in BDCP2 that means there is no problem in Change
    pointer creation, Just ruling out possibility.
    Try with an user exit it's a good idea, but why in the PFAL the idoc (with the custom segments)
    is created without problems and in the BD21 no??? This is very strange
    1) Well BD21 uses the Function module (TBDME for HRMD_A) which read change pointers and
    create IDOCs. So now if you have extended Segment you have to add your population code
    here somewhere.
    2) PFAL is Push program, my assimption here is you have wriiten some piece of code to
    populate Additinal segments data here? Otherwise IDOC will not be populated
    automatically.
    Let me know what you think.

  • Problem deleting infotypes

    Hello
    I've tried to create a new infotype, 9026.
    The first time, I accidently created it as a PA infotype instead of HRP. When I tried to delete it, using PM01, some of the items created have stayed on the system, under TADIR entries:
    TABL HRI9026
    TABL P9026
    PROG MP902600
    PROG MP902620
    Though when I try to access them using SE38 or SE11 they don't exist.
    Then, I've tried to create it as 9126, in PPCJ.
    After it's been customized, I tried to delete it as well, from PPCI, and again it left TADIR entries, all the entries it searched for.
    How can I delete these infotypes completly?
    thanks

    Hi  Udi,
    Check the tables where the entries are left
    T582A, T582S, T777A, T77ID, T777D, T582C.
    Reply what are the entries ?
    Manoj Shakya.
    Techno-Fuctional Consultant
    SAP-HR
    ******(Useful answers should be rewarded)

  • Creation of Custom Infotypes

    Hi Guy's,
    Please help me How to create the Custom Info types in Campus management(Step-by-Step) procedure.
    Thanks,
    Bhavani.
    Edited by: Michael Fan  on Mar 13, 2008 2:33 PM - I changed to title to something more meaningful.

    Hi ,
    For OM infotypes it is PPCI and PD infotypes  it will be PM01.
    Just find this in the ERP HCM where you can find the links .
    Refer this link :
    http://help.sap.com/erp2005_ehp_03/helpdata/EN/1e/728d281d5e11d289d30000e82158f1/frameset.htm
    Regards
    Gajalakshmi

  • How  to  create an infotype in sap ecc6.0 ?

    Hi all,
    I know i how to create an infotype   in   sap 4.7, but i am facing the problem while
    creating an infotype in sap ecc6.0 version. could u plz provide me  the info with screen shots how to create an infotype and how to enhace that infotype ?
    Waiting for u r response.
    Regards,
    Ravi

    Hi ,
    To create OM infotype:
    1. Go to SE11 and create a structure HRI9XXX (9XXX --> name of the infotype). Add the required fields to this structure and save and activate. then come out of it.
    2. Go to PPCI and enter Infotype number (9XXX) and description.
    3. Click create.
    4. In the infotype category select details for the infotype.
    5. Click create button. It should create the infotype.
    6. Click on Check. A window with menu will open.
    7. In that window navigate to Table Entries.
    8. Under table Entries, select T777I and click on change.
    9. It opens SM30. Click on Maintain.
    10. Select the infotype and add information for "Time Constraint" and "Infotype Per Object Type".
    11. Save.
    12. Go back to check menu, see if all entries exist. Do not worry last 5 table entries. And you are done

  • CREATION  OF 'PB'  INFOTYPE

    HI ,
    I AM ABLE TO CREATE THE ''PA'' INFOTYPE BY USING''PM01''
    BUT,
    I AM NOT GETTING HOW TO PROCEDE FOR ''PB'' INFOTYPE PLZ LET ME KNOW,
    THIS IS VERY URGENT,
    THANKS IN ADVANCE ,
    SAI

    Hi Sai Krishna,
    Take your time to see detail information to create Infotypes, The following liks will give you detail understanding of infotype creation - Applicant Infotypes & Personnel Infotypes
    1. http://www.sapdevelopment.co.uk/hr/hr_infotypes2.htm
    2. http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAXX/PYINT_INFOTYP.pdf
    3. http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAXX/PYINT_INFOTYP_PD.pdf
    4. Photograph and PM01
    Sure, It will help you & it will slove your problem..!
    Cheers,
    TG

  • Adding Custom Infotype to a Infoset

    Hi,
    I have created a Custom Infotype for OM with some custom fields.These fields need to be made available to the Infoset for Adhoc Query.
    Any idea how this infotype can be added to the infoset?
    or made available for Queries.
    Thanks,
    Vijay

    Here are the steps that I followed:
    Enter the transaction code PPCI
    Enter a four digit infotype number (9nnn) and an infotype name.
    Select Field Infotype
    Choose Infotype Create.
    Choose Check environment to maintain the required entry in table T777I (Infotypes per object type).
    Choose the Entry 'T777I' under the list of 'Table Entries' (This list is produced when you choose 'Check' on the First screen of the Transaction PPCI.
    Press the 'Change' button and you will be taken to the 'Maintain Table Views' Transaction (SM30).
    Press the Maintain button.
    From the list of Infotypes locate the custom infotype created and select the entry for that.
    Click on the 'Time Constraint' folder appearing on the left hand corner of the screen.
    The screen for Change View Time Constraint would appear.
    In the object type field put in: O,P,S whatever is relevant to your requirement.Also add the time constraint.
    Save it and double click on the 'Infotypes per object type' folder (on the left hand side again).
    Create a new entry here for your infotype and save it.
    Come back to the Transaction PPCI and you are all set.
    This is all I did and it worked.
    Thanks,
    Vijay

  • How to create an Infotype in OM

    Dear all,
    Can any one please let me know How to create an Infotype in OM.
    thanks
    abdul

    Hi ,
    To create OM infotype:
    1. Go to SE11 and create a structure HRI9XXX (9XXX --> name of the infotype). Add the required fields to this structure and save and activate. then come out of it.
    2. Go to PPCI and enter Infotype number (9XXX) and description.
    3. Click create.
    4. In the infotype category select details for the infotype.
    5. Click create button. It should create the infotype.
    6. Click on Check. A window with menu will open.
    7. In that window navigate to Table Entries.
    8. Under table Entries, select T777I and click on change.
    9. It opens SM30. Click on Maintain.
    10. Select the infotype and add information for "Time Constraint" and "Infotype Per Object Type".
    11. Save.
    12. Go back to check menu, see if all entries exist. Do not worry last 5 table entries. And you are done

  • Custom infotype replacement for dialog modules

    Hi,
    I have been asked to recreate a custom OM infotype (created with PPCI and based on the Planned Compensation infotype) to the new SAP EHP4 environment.  Part of the infotype is a custom dialog maintenace module that allows the infotype to be viewed and maintain with the PP01 transaction (planned compensation is linked to a job).
    When I recreate the code in the new environment (I cannot use a transport), I am unable to recreate the dialog module because the system says "dialog modules are obsolete and no longer supported."  Can you tell me what is the new way to create the new maintenance screen and have it work with PP01.  Also, it seems that if I try to change the configuration table T777D (using SM30) with something other than a dialog module name, it doesn't accept it, so where does the new maintenance screen go in that table?
    Thank you in advance for your help.
    Christian Durini.

    Hi,
    whereever we create a custom OM infotype using PPCI transaction, the system will go to next level as with titles as
    - Module Pool Program
    - Screens
    - Tables and etc...
    so as per the structure of Module Pool Program, first of all we have to create Program (Double click on each Program after that the cursor will to next screen.here we have to click on create button). After that go to SE51 and enter the program and screen number, click on change button. 
    Normally whenever we create info type the system will maintain with screens as 1000, 2000, 3000
    follow above procedure for 3 screens.
    Ram.

  • Custom Infotype Creation in ORG Management

    Vijay,
    Can you send me the steps so I can assign the points.
    Thanks,
    Parina

    Here are the steps that I followed:
    Enter the transaction code PPCI
    Enter a four digit infotype number (9nnn) and an infotype name.
    Select Field Infotype
    Choose Infotype Create.
    Choose Check environment to maintain the required entry in table T777I (Infotypes per object type).
    Choose the Entry 'T777I' under the list of 'Table Entries' (This list is produced when you choose 'Check' on the First screen of the Transaction PPCI.
    Press the 'Change' button and you will be taken to the 'Maintain Table Views' Transaction (SM30).
    Press the Maintain button.
    From the list of Infotypes locate the custom infotype created and select the entry for that.
    Click on the 'Time Constraint' folder appearing on the left hand corner of the screen.
    The screen for Change View Time Constraint would appear.
    In the object type field put in: O,P,S whatever is relevant to your requirement.Also add the time constraint.
    Save it and double click on the 'Infotypes per object type' folder (on the left hand side again).
    Create a new entry here for your infotype and save it.
    Come back to the Transaction PPCI and you are all set.
    This is all I did and it worked.
    Thanks,
    Vijay

  • Re: Org Management

    Hello, we have a requirement where certain positions in our org.structure require a drug test to be taken on a random basis. We would like to see this info at the object level 'S'. This is my first task in OM area and new to OO cncept. Would like to have some direction on how to implement this. Which object types & relationships need to be established...etc..
    Thanks
    vsap

    You can also create custom infotype (transaction PPCI) and put the necessary data in the custom infotype.
    Regards,
    Sandip

  • Doubts in CREATION  OF 'PB'  INFOTYPE

    hi i created infotype but while executing this in pb30
    it is showing the error like.....
    """"""P9030" must be a flat structure. You cannot use internal tables,         
    strings, references, or structures as components"""""""".
    now how can i procede, 
    plz let me know ,
    this is very urgent ,
    thank you ,
    sai.

    Hi Sai Krishna,
    Take your time to see detail information to create Infotypes, The following liks will give you detail understanding of infotype creation - Applicant Infotypes & Personnel Infotypes
    1. http://www.sapdevelopment.co.uk/hr/hr_infotypes2.htm
    2. http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAXX/PYINT_INFOTYP.pdf
    3. http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAXX/PYINT_INFOTYP_PD.pdf
    4. Photograph and PM01
    Sure, It will help you & it will slove your problem..!
    Cheers,
    TG

  • OM inotype does not exist in PO13

    Hi I have created an OM infotype as 9901(pozisiton infotype) in PPCI.And then I completed required settings in infotype checklist.Everything is OK. However in Transaction  PO13 , my infotype is not in thi list.

    Hi Kamil, go to T-code "<b>OOIT</b>" and maintain the infotype for the Object type.
    <b>Do not</b> select the check box "No Mainten"
    Bhawanidutt.

Maybe you are looking for