Problem with PNP customized selection screen
Hi guys,
I have done a report in R/3 system using logical database PNP with customized selection screen. i have 3 parameters as below:
1. radiobutton1 group a for current period,
2. radiobutton2 group a for other period.
3. personnel number.
my program works fine in R/3 but not in my portal. i think it couldn't recognize my radiobutton in my customized screen. whichever radiobutton i selected also it would return current month records.
any idea how to fix this?
any configuration that i can do?
thanks.
try testing it through ITS first.
in order to do so . Go to sicf transaction and run webgui. Then run the application using the tcode. Check the results.
Seems wrong paramter are getting passed to the SAP system.
Your ITS server should be activated first in order to use webgui otherwise you will be getting dump.
Regards
Atul Shrivastava
Similar Messages
-
Problem with the default selection screen condition
hi guys,
I have got some problem with the default screen given by the PNP logical database, P0000 infotype automatically populated according to the condition given in default screen.
Reg,
HariharanDon know what u r trying to acheive.
1) when u have specified PNP in the logical databse field of attributes of program, the SAP wil proivde u default PNP screen and here u can also add ur paramters if u want.
2) in the program u have to declare like
INFOTYPES: 0000,0001. "Etc
for all the infotypes u want to use in the program.
3) it is the GET PERNR event which wil fil all the p0000 and p0001 (internal tables for al the infotypes declared via INFOTYPES syntax as shown above)
4) after tht get pernr, u now have data in P tables and u can use it for further reporting.
5) refer below dummy code -
REPORT ZPPL_PREVEMPLOYERS message-id rp
line-size 250
line-count 65.
*Program logic :- This Report is used to Download all the Previous
* Employer (IT0023) records of the employees
*eject
*& Tables and Infotypes *
tables: pernr.
infotypes: 0000,
0001,
0002,
0023.
*eject
*& Constants *
constants: c_1(1) type c value '1' ,
c_3(1) type c value '3' ,
c_i(1) type c value 'I' ,
c_x(1) type c value 'X' ,
c_eq(2) type c value 'EQ' ,
c_pl03 like p0001-werks value 'PL03'.
*eject
*& Selection-Screen *
parameters: p_file like rlgrap-filename default 'C:TempABC.xls',
p_test as checkbox default c_x .
*eject
*& Internal tables *
* Internal Table for Output
data: begin of t_output occurs 0 ,
pernr like pernr-pernr ,
nachn like p0002-nachn ,
vorna like p0002-vorna ,
orgeh_stext like p1000-stext ,
plans_stext like p1000-stext ,
begda like p0023-begda ,
endda like p0023-endda ,
land1 like p0023-land1 ,
arbgb like p0023-arbgb ,
ort01 like p0023-ort01 .
data: end of t_output .
*eject
*& Variables *
data: o_stext like p1000-stext,
p_stext like p1000-stext.
*eject
*& Initialization *
Initialization.
* Initialize Selection-Screen values
perform init_selction_screen.
*eject
*& AT Selection-screen *
at selection-screen .
* Check if Test run selected, download file name should be entered
if p_test is initial. "
if p_file is initial.
message e016 with 'Please enter file name'
'specifying complete path'.
endif.
endif.
*eject
*& Start-of Selection *
Start-of-selection.
get pernr.
clear t_output.
* Read Infotype 0
rp-provide-from-last p0000 space pn-begda pn-endda.
check pnp-sw-found eq c_1.
* Check if employee is active
check p0000-stat2 in pnpstat2. "pernr Active
* Read Infotype 1
rp-provide-from-last p0001 space pn-begda pn-endda.
check pnp-sw-found eq c_1.
* check if employee belongs to PL03
check p0001-werks in pnpwerks. "belongs to PL03
* Check if emp belongs to Active Group
check p0001-persg in pnppersg.
* Read Infotype 2
rp-provide-from-last p0002 space pn-begda pn-endda.
check pnp-sw-found eq c_1.
* Read Org Unit Text.
CALL FUNCTION 'HR_READ_FOREIGN_OBJECT_TEXT'
EXPORTING
OTYPE = 'O'
objid = p0001-orgeh
begda = p0001-begda
endda = p0001-endda
reference_date = p0001-begda
IMPORTING
object_text = o_stext
EXCEPTIONS
nothing_found = 1
wrong_objecttype = 2
missing_costcenter_data = 3
missing_object_id = 4
OTHERS = 5.
*Read Position Text.
CALL FUNCTION 'HR_READ_FOREIGN_OBJECT_TEXT'
EXPORTING
OTYPE = 'S'
objid = p0001-plans
begda = p0001-begda
endda = p0001-endda
reference_date = p0001-begda
IMPORTING
object_text = p_stext
EXCEPTIONS
nothing_found = 1
wrong_objecttype = 2
missing_costcenter_data = 3
missing_object_id = 4
OTHERS = 5.
* Gather all the required information related to the emp
move: pernr-pernr to t_output-pernr,
o_stext to t_output-orgeh_stext,
p_stext to t_output-plans_stext,
p0002-nachn to t_output-nachn,
p0002-vorna to t_output-vorna.
* Gather previous Employee details
loop at p0023.
move-corresponding p0023 to t_output.
append t_output.
endloop.
*eject
*& End-of Selection *
end-of-selection.
perform print_report.
* Downlaod the file
if not t_output[] is initial.
if p_test eq space.
perform download_file.
endif.
else.
write: 'No records selected' color col_negative.
endif.
*eject
*& Top-of-page *
Top-of-page.
* Print Header
perform print_header.
*eject
*& Form download_file
* Description :
FORM download_file .
DATA: full_file_name TYPE string,
z_akt_filesize TYPE i .
full_file_name = p_file.
* download table into file on presentation server
CALL METHOD cl_gui_frontend_services=>gui_download
EXPORTING
filename = full_file_name
filetype = 'DAT'
NO_AUTH_CHECK = c_x
codepage = '1160'
IMPORTING
FILELENGTH = z_akt_filesize
CHANGING
data_tab = t_output[]
EXCEPTIONS
file_write_error = 1
no_batch = 2
gui_refuse_filetransfer = 3
invalid_type = 4
no_authority = 5
unknown_error = 6
header_not_allowed = 7
separator_not_allowed = 8
filesize_not_allowed = 9
header_too_long = 10
dp_error_create = 11
dp_error_send = 12
dp_error_write = 13
unknown_dp_error = 14
access_denied = 15
dp_out_of_memory = 16
disk_full = 17
dp_timeout = 18
file_not_found = 19
dataprovider_exception = 20
control_flush_error = 21
not_supported_by_gui = 22
error_no_gui = 23
OTHERS = 24.
IF sy-subrc NE 0.
MESSAGE e016 WITH 'Download-Error; RC:' sy-subrc.
ENDIF.
ENDFORM. " download_file
*eject
*& Form print_report
*Description:
FORM print_report .
data: i type i,
w_count type i.
sort t_output.
* Print the report
loop at t_output.
i = sy-tabix mod 2.
if i eq 0.
format color col_normal intensified on.
else.
format color col_normal intensified off.
endif.
write:/1 t_output-pernr ,
10 t_output-vorna(25) ,
35 t_output-nachn(25) ,
61 t_output-orgeh_stext ,
102 t_output-plans_stext ,
143 t_output-begda ,
154 t_output-endda ,
168 t_output-land1 ,
178 t_output-arbgb(40) ,
219 t_output-ort01 ,
249 space .
endloop.
uline.
Describe table t_output lines w_count.
Skip 2.
Write:/ 'Total No of Records Downloaded: ' color col_total,
w_count.
ENDFORM. " print_report
*eject
*& Form print_header
*Description:
FORM print_header .
skip 1.
Uline.
format Intensified on color col_heading.
write:/1 'Pers. #' ,
10 'Last Name' ,
35 'First Name' ,
61 'Org Unit' ,
102 'Position' ,
143 'Beg Date' ,
154 'End Date' ,
168 'Cntry Key' ,
178 'Prev Employer' ,
219 'City' ,
249 space .
format intensified off color off.
uline.
ENDFORM. " print_header
*eject
*& Form init_selction_screen
*Description:
FORM init_selction_screen .
refresh: pnpwerks,
pnppersg,
pnpstat2.
clear: pnpwerks,
pnppersg,
pnpstat2.
pnpwerks-sign = c_i.
pnpwerks-option = c_EQ.
pnpwerks-low = c_pl03.
append pnpwerks.
pnppersg-sign = c_i.
pnppersg-option = c_EQ.
pnppersg-low = c_1.
append pnppersg.
pnpstat2-sign = c_i.
pnpstat2-option = c_EQ.
pnpstat2-low = c_3.
append pnpstat2.
ENDFORM. " init_selction_screen -
Problem with CURSOR on Selection-Screen
Hi Experts,
This question is for you. We have recently upgraded our system to 7.01 Stack 5 (Enhancement Pack 1).
The screen supplied by a custom transaction is quite behaving in a strange manner. Whenever we execute the transaction the CURSOR appears by default at the 3rd Radio button and the UP/DOWN keys present in keyboard are not working and we have to place it back to the correct position using Mouse.Our customer raised a Ticket to check this.
Please suggest a work around for this.I need to remove this cursor blink completely at the selection screen.
Best Regards,
lakshman.Hi,
Not sure to really get the issue... looks like your radiobuttons are not grouped properly and default is set on the third one...(?)
So just use the same radiobutton group for the three buttons and set the first one as default, either on selection screen or initialization level...
Kr,
Manu. -
Problem with user defined selection-screens
Hi,
in my case, i have a default selection screen and a user defined selection screen. Now, after selecting a radio button in default selection screen, the user defined selection screen is called. after executing it report output is displayed. now if i press f3 (back) it is going to default selection screen. here my requirement is, when i press f3 it should go to the user defined selection.
Can u plz help me solve this.
bye n regards
sreeAny modifications to screen 1000 will be lost the next time the program is generated.
When the user hits the back key from the report output, your ABAP is restarted just like when you originally started it. That is why you are getting the default selection screen again.
Use the AT USER-COMMAND event. When BACK is hit from the report, use the SUBMIT command to re-execute the program, passing it the selections from the default selection screen. Leave out the RETURN option.
For help on filling the selection screen during SUBMIT, help is available at
http://help.sap.com/saphelp_470/helpdata/en/9f/dba51a35c111d1829f0000e829fbfe/frameset.htm -
Problem with logic at-selection screen
Hi ,
I have this piece of code :
I have 3 radiobuttons and corresponding screens and fields like r_matnr s_charge etc on that screen .
default radio button is r_build .
a) If on this screen is user forgots to give value for s_matnr then error is given .
now if we click on r_conf the contents of display screen when r_buld was pressed should be gone ..
the r_matnr , r_werks etc . should be blank .
what i should do to implement it ? also validation of point a) should be performed for the current values of that screen .
plz help..
SELECTION-SCREEN BEGIN OF LINE.
PARAMETERS: r_build RADIOBUTTON GROUP r1 USER-COMMAND act DEFAULT 'X'.
PARAMETERS: r_conf RADIOBUTTON GROUP r1.
SELECTION-SCREEN BEGIN OF LINE.
SELECT-OPTIONS : s_matnr FOR mara-matnr MODIF ID c.
SELECTION-SCREEN END OF LINE.
SELECTION-SCREEN BEGIN OF LINE.
SELECT-OPTIONS : s_charg FOR mch1-charg MODIF ID c.
SELECTION-SCREEN END OF LINE.
LOOP AT SCREEN.
IF r_conf = 'X'.
IF screen-group1 = 'A'.
screen-active = 0.
ENDIF.
ELSE.
IF r_rel = 'X'.
IF screen-group1 = 'A' OR screen-group1 = 'B'
OR screen-group1 = 'C'.
screen-active = 0.
ENDIF.
ENDIF.
ENDIF.
MODIFY SCREEN.
ENDLOOP.
AT SELECTION-SCREEN ON s_matnr.
IF s_matnr IS NOT INITIAL.
some select where = s_matnr .
MESSAGE e019(zesapp).
LEAVE TO SCREEN 0.
ENDIF.
plz help..
Regards .hi ujjwal,
can you please elaborate on "the values are getting blank just after entering it ."...
you mean material number gets blank after you enter the value?
also in the below code you are checking material number NOT INITIAL that means some value is entered and if it does not satisfy the SELECT condition then it will give error message and navigate u again to your initial screen...maybe this could be the reason for the blank values...
AT SELECTION-SCREEN ON s_matnr.
IF s_matnr IS NOT INITIAL.
some select where = s_matnr .
MESSAGE e019(zesapp).
LEAVE TO SCREEN 0.
ENDIF.
hope this is helpful. -
Problem with validation of selection screen
I am creating session process for BDC
For that i am taking the flat file at runtime.i want check whether the entered file is valid or not..that means it exists are not?
how to do that..Hi,
DATA: W_FILENAME TYPE STRING,
W_RESULT TYPE C.
W_FILENAME = WK_DIRECTRY.
CALL METHOD CL_GUI_FRONTEND_SERVICES=>FILE_EXIST
EXPORTING
FILE = W_FILENAME
RECEIVING
RESULT = W_RESULT
EXCEPTIONS
CNTL_ERROR = 1
ERROR_NO_GUI = 2
WRONG_PARAMETER = 3
NOT_SUPPORTED_BY_GUI = 4
others = 5.
IF SY-SUBRC 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-* MSGNO WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
IF W_RESULT IS INITIAL.
CALL METHOD CL_GUI_FRONTEND_SERVICES=>DIRECTORY_EXIST
EXPORTING
DIRECTORY = W_FILENAME
RECEIVING
RESULT = W_RESULT
EXCEPTIONS
CNTL_ERROR = 1
ERROR_NO_GUI = 2
WRONG_PARAMETER = 3
NOT_SUPPORTED_BY_GUI = 4
OTHERS = 5.
IF SY-SUBRC 0.
ENDIF.
ENDIF.
IF W_RESULT = 'X'.
RC = '1'.
ELSE.
RC = '0'.
ENDIF.
Regards,
nagaraj -
RE:pnp LDB selection screen problem
hi,
hi friends iam facing one problem regarding hr ABAP selection screen ,in my program iam using PNP LDB for bonus details report
i have using selection screen declaration present for single selection.
SELECTION-SCREEN BEGIN OF BLOCK B3 WITH FRAME TITLE TEXT-006.
SELECT-OPTIONS: S_ABKRS FOR P0001-ABKRS NO INTERVALS NO-EXTENSION,
S_WERKS FOR P0001-WERKS NO INTERVALS NO-EXTENSION,
S_BTRTL FOR P0001-BTRTL NO INTERVALS NO-EXTENSION,
S_PERSG FOR P0001-PERSG NO INTERVALS NO-EXTENSION,
S_PERSK FOR P0001-PERSK NO INTERVALS NO-EXTENSION.
SELECTION-SCREEN END OF BLOCK B3.
based on this selection iam fetching the information from infotypes using macros.
now my requirement is iam fetch the information for multiple selections means like payroll areas z1,z2 and z3 payroll informations
should be fetching once. pls any body knows solution please give me reply.
thanks & regards,
mgrao.hi jain thanks for your reply, iam already created report category and assigned my report. here iam giving my report selection
declerations fully below.
S E L E C T I O N S C R E E N *
SELECTION-SCREEN BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001. " DECLEARED REPORT CODE LEVEL
SELECT-OPTIONS: S_DATE FOR SY-DATUM NO-EXTENSION. "Bonus for Financial Year
PARAMETERS: P_BDATE TYPE SY-DATUM OBLIGATORY, "Bous payed as on
P_WKDAYS TYPE CHAR6. "No.of Working Days
SELECTION-SCREEN END OF BLOCK B1.
*SELECTION-SCREEN BEGIN OF BLOCK B3 WITH FRAME TITLE TEXT-006. " COMMENTED report level TAKING FROM LDB PNP
*SELECT-OPTIONS: S_ABKRS FOR P0001-ABKRS NO INTERVALS NO-EXTENSION, " Payroll area
S_WERKS FOR P0001-WERKS NO INTERVALS NO-EXTENSION, Personnel area
S_BTRTL FOR P0001-BTRTL NO INTERVALS NO-EXTENSION, Personnel sub area
S_PERSG FOR P0001-PERSG NO INTERVALS NO-EXTENSION,
S_PERSK FOR P0001-PERSK NO INTERVALS NO-EXTENSION.
*SELECTION-SCREEN END OF BLOCK B3.
SELECTION-SCREEN BEGIN OF BLOCK B2 WITH FRAME TITLE TEXT-002. "REPORT CODE LEVEL SELECTION
PARAMETERS: P_FORMCP TYPE PIN_RATE, " char6, "Form C %
P_FORMEP TYPE PIN_RATE, " char6, "Exgratia %
P_FORMBP TYPE PIN_RATE. " char6 . "Bonus %
SELECTION-SCREEN END OF BLOCK B2.
SELECTION-SCREEN BEGIN OF BLOCK B4 WITH FRAME TITLE TEXT-004.
PARAMETERS: L_REPORT TYPE ZHRD_FORMC AS LISTBOX VISIBLE LENGTH 40 OBLIGATORY . Report for list box 1 form c
SELECTION-SCREEN END OF BLOCK B4. 2 exgratia
the above selection is iam used first, now iam commented BLOCK B3 SELECTION PARAMETERS and taking the parameters from REPORT CATEGORY ASSINGN MENT.
MY PROBLEM is if i select one payroll area example z1 it showing all pay roll employees bonus details it is not filter the remaining payroll areas my requirement is what are the payrolls iam selecting those pay roll area details only displaying.
data fetching from INFOTYPES 0001,0002,0021 AND 9150 FOR BONUS DETAILS and out put is classical report format.
please kindly give the reply if you knows the solution.
thanks & regards ,
mgr. -
PNP and Selection Screen 900 and Authorization
We have used the combination of logical db PNP with selection screen 900 to write a few custom payroll reports. We noticed right away that this combination seems to ignore HR authorizations. Meaning, someone could read payroll results for employees they are not authorized to see. We had to add our own authorization checks.
Am I missing something or is something wrong with the 900 selection screen?Hi Kenneth,
The 900 selection screen is for evaluation of Payroll Results. The system checks whether the user who started the evaluation has the correct authorization for this evaluation. Since the data retrieval is from the Payroll Results and not Master data the regular Authorization checks might not be relevant here. Even if the User has no authorization to view the Employee's Master data, he/she might still be able to view the Payroll results via this selection screen if he /she has the evaluation authorization. You are probably right in having to put in your own authorization checks. I hope I am not wrong.
Regards,
Suresh Datti
Message was edited by: Suresh Datti -
Error while transporting the Custom Selection Screen to Production
Hi All ,
I have created a custom selection screen based on selecting the HR REPORT CATEGORY which gets selected under attributes section of an Executable Program.
Every selection screen got replicated till quality but at Production unable to see the same selection screen
Please provide any suggestion to resolve my probs...
Regards,
DheerajHi,
This happened to me once.
I have checked my transport logs and found that everything was successfully transported in order and without errors. But the selection screen was not coming in Productio system. So i have tried activaing and generating the program once which solved my problem.
Hope it helps you too.
Thanks,
Venkatesh. -
F-32 : Problem with Open Item selection
Hi,
We have a strange problem with open Item selection for customer clearing in t-code F-32
In My QA system
if I input spl GL indicator ="*" and uncheck Normal OI tick,
the system selects all open items,
(those with spl GL indicator and those without spl GL indicator)
In My Dev system
If I input spl GL indicator ="*" and uncheck Normal OI tick
the system does not select any open items,
Please let me know which setting controls this behaviour ?
Regards
SachinHello,
Check your data in FBL5N for the option "Special GL Transactions". There could be that there is no data in the system with SPECIAL GL TRANSACTIONS.
In F-32, there is no value like *
You need to input right Special GL Indicator. "*" will not work here.
I am sure in both the systems if you put "*" and UNTICK your normal transaction, you will NOT get any items to clear.
Please DOUBLE CHECK whether you have unticked normal transaction.
Regards,
Ravi -
Problem in enabling the selection screen
Hi ,
I have problem in enabling the selection screen.
i have radio button and based on the radio button i need to make the date field as mandatory.
When i tried this with at selection screen on radio button group XXX, itu2019s not triggering.
Could you please help me by resolving the above problem?
VijayHi,
see the sap documentation
... RADIOBUTTON GROUP group [USER-COMMAND fcode]
Effect:
This addition specifies that the input field is displayed as a radio button in the first position on the selection screen, and the output field is displayed next to it on the right. The radio button is selected if the value of para is "X" or "x". Otherwise, it is not selected.
group is used to define the radio button group for the parameter. The name group is entered directly as a character string with a maximum of 4 characters. Within a selection screen, there must be a minimum of two parameters in the same radio button group. There cannot be more than one radio button group with the same name in one program, even if they are defined in different selection screens.
The parameter must be specified with the type c and length 1. Explicit length specification using len is not permitted. If the addition TYPE is used, it can only be followed by the generic type c or a non-generic data type of type
In a radio button group, only one parameter can be defined with the addition DEFAULT, and the specified value must be "X". By default, the first parameter in a radio button group is set to the value "X", and the rest are set to " ".
The addition USER-COMMAND can be used to assign a function code fcode to the first parameter in a radio button group. The function code fcode must be specified directly, and have a maximum length of 20 characters. To evaluate the function code, an interface work area of the structure SSCRFIELDS from the ABAP Dictionary must be declared using the statement TABLES. When the user selects any radio button of the radio button group on the selection screen, the runtime environment triggers the event AT SELECTION-SCREEN and transfers the function code fcode to the component ucomm of the interface work area sscrfields. If a function code used in the GUI status of the selection screen is specified for fcode, the selection screen processing is affected accordingly.
Note:
It is recommended to define the radio buttons of a radio button group directly underneath each other. If the selection screen also contains other elements, it is recommended to define each radio button group within a block surrounded by a frame.
Regards,
Venkatesh -
Including User selection criteria along with LDB standard selection screen
Hi
While creating a HR report, along with the standard selection screen, if the cusomer requires some more fields to be added, How to retrive the data from the DB?
Is it the way to retrive the data based on Standard selection criteria from the LDB and then filter it based on user criteria or any other way?
Please help me out in this regard.
Thank you.Yes thats the way. You get the data based on Selection screen of LDB (You can select Report Catogory you wish to) once you get data, You can put CHECK statement to see the data against PXXXX type to the filter value from you custom field on selection screen.
-
Problem with PnP devices, Unknown device, error code:28
Hello, my USB Mass Storage Device Not Recognized( Flash drive- HP v156w, 16 GB)
Full story : I opened flash disk, started to loading and opening files very slow, suddenly all writing, names of the files become unreadable. I took off the flash disk and try again. I got the message- disk have to be formated to be used
again. After a lot of try I got this message:
Unknown device doesn't have a driver ; and Problem with PnP devices when i run trouble shoot in devices and printers on my Sony VAIO laptop( Windows 8, 64 bit), and error code:28 for unknown device doesn't have a driver.
Do other usb devices work ok in the same usb port? - yes
Has someone else/or you used it on another pc?- yes
Does it work ok on a different pc? - the same problem
Did you pull it out with using 'Safely Remove Hardware'? - yes, a lot of time after its become invisible, unknoun
Was it previously working ok with your W8 laptop? - never tried befor
Disk Management can't see the drive.
device manager:
usb device with yellow sine and instead name strange sines
divice tipe - other devices
manufacturer - unknown
location- on USB Mass Storage Device
status: The drivers for this device are not installed. (Code 28)
To find a driver for this device, click Update Driver.
I have done that -
"open device manager make sure show hidden devices is ticked and right click on all the USB hidden devices and unistall them. once done reboot and put in the flash drive again and see if windows finds it."
situation the same(((( Disk Management can't see the drive.
please if any one know the fix please help
Its very important info for me on the flash disk.I'd ask them over here.
http://answers.microsoft.com/en-us/windows/forum/windows_8?tab=Threads
Regards, Dave Patrick ....
Microsoft Certified Professional
Microsoft MVP [Windows]
Disclaimer: This posting is provided "AS IS" with no warranties or guarantees , and confers no rights. -
I have problems with office for mac screen resolution, specially with excel
I have problems with office for mac screen resolution, specially with excel ?
For starters, make sure to Check for Updates on any of the Help menus, and make sure the product has all the latest patches. MS did come out with a patch addressing the display issues on Retina Macs. Latest patchlevel is 14.3.2.
We are talking about Office:Mac 2011, right? -
Customizing selection screen display
hey,
i am defining selection screens..i want to control the screen size, as it is going beyond my screen limits. also i want to customize the field names..or e.g. if i choose kna1-kunnr, kunnr is displayed, insetad i want "customer number" to be displayed. how to handle all these ?
thksCheck the Below code.
Report ZTEST_MOD.
data: kunnr(10).
* Custom Selection Screen 0200
selection-screen begin of screen 0200 as subscreen.
select-options: s_kunnr for kunnr.
selection-screen end of screen 0200.
at selection-screen on value-request for s_kunnr-low.
break-point.
start-of-selection.
call screen 100.
*& Module STATUS_0100 OUTPUT
module status_0100 output.
SET PF-STATUS 'STATUS'.
endmodule.
*& Module USER_COMMAND_0100 INPUT
module user_command_0100 input.
endmodule.
Flow Logic
PROCESS BEFORE OUTPUT.
MODULE status_0100.
CALL SUBSCREEN sub INCLUDING sy-repid '0200'.
PROCESS AFTER INPUT.
MODULE user_command_0100
We have to do the normal report event
at selection-screen on value-request
Regards
Vijay babu Dudla
Maybe you are looking for
-
Please help, I am trying to split a HD mp4 video into two parts using Quicktime 10.2
Please help, I am trying to split a HD mp4 video into two parts using Quicktime 10.2, running Mountain Lion. I use trim then export but it doesn't give the movie option as a format. What would you suggest i do?
-
I cannot figure out what I am missing here. I have a PDF Portfolio completed and now want to E-Mail for Review. But this option is greyed out on my Comment Menu dropdown list. What to do? Thanks!
-
Issues embedding swf in pdf document?