Programmer's ref. manual for NI-PCI-6014 board?

Do you have programmers reference manual for NI-PCI-6014 data acquisition board?

NI-DAQ is the driver that interfaces with the PCI-6014. All of the NI-DAQ functions are described in the NI-DAQ Function Reference Online Help file. To view the NI-DAQ Function Reference Online Help, select Start»Programs»National Instruments»NI-DAQ»NI-DAQ Help.

Similar Messages

  • Where can I download IMAQ driver version 1.0 for the PCI-1408 board?

    Because of the computer crash I have to reinstall the NI-IMAQ driver version 1.0 for my PCI-1408 board. I couldn't find the original IMAQ driver which came with the PCI-1408 board. Could anybody tell me where I can download the software? Thank you very much.
    Solved!
    Go to Solution.

    Lowest version I could locate on the ftp site was 1.5, that may work:
    ftp://ftp.ni.com/support/imaq/pc/ni-imaq/
    -AK2DM
    ~~~~~~~~~~~~~~~~~~~~~~~~~~
    "It’s the questions that drive us.”
    ~~~~~~~~~~~~~~~~~~~~~~~~~~

  • Where can I download LabVIEW example codes for NI PCI-6014

    I bought an PCI-6014 DAQ device, please tell me where I can download the LabVIEW codes for this device.

    Hi,
    If you have labview package, you can find lot of examples there.
    Start Labview -> Help Menu -> Find Examples-> Hardware input and output -> DAQ -> Here you either you can go to analog input -> then general -> search vi as per your requirement.
    Or you can use timer/counter/digital input & output example vi from here.
    Hope it helps. Your feedbacks are welcome.
    Best Regards,
    Nirmal

  • I need a user manual for a PCI-MIO-16E-1 DAQ card

    I am starting research using a PCI-MIO-16E-1 DAQ card that was used by a prior student and the manual is not available.  I tried to access the manual online through your websitem, but I was denied access.  How can I gain access to this manual so I can start to use this DAQ in my research?

    What you need is the E Series help file.  Here is the link, but for some reason if you can't get there, the zip file is attached.
    -Alan A.
    Attachments:
    370503f.zip ‏1260 KB

  • Incremental encoder: reset counter on pci 6014?

    I want to connect an incremental encoder with A, B and Z to a PCI 6014 card. I found some VI's for counting A and B (DAQmx->Counter->Count Digital Events; DAQmx->Counter->Measure Posititon) . However I can't figure out what to do with the Z. Is there a way to reset the counters by Z? (I am using labview 2009)
    Thank you very much!

    Sorry, my fault. I didn't see you have an E-Series device.
    Resetting your counter with a digital trigger is possible for Counter/Timer devices but not for your PCI 6014.
    You can reset the counter with DAQmx by stopping and starting the task again. You could read your Z index on a digital input, if the input goes high (or low) you could reset the counter.
    DAQmx: Count Digital Events with Option to Reset Counter
    http://decibel.ni.com/content/docs/DOC-6576 
    I think this is the only way for the PCI 6014. Since you have to go through several software layers, the performance goes down a bit. If it is possible, i would recommend to change to a M-Series device...
    Cheggers
    Sascha E.
    Group Leader Applications Engineering
    National Instruments Switzerland

  • PCI-6014 not recognized by Windows 2000

    I recently purchased and just installed a PCI-6014 in a new Dell Optiplex running Windows 2000 (sp2, we have stayed at sp2 due to problems we have had with sp3, sp4). On this same machine I have LabVIEW 7.0 with all the bells, including NI-DAQ 7.0. When I put the pci card in for the first time (and every one of many times I have restarted since) I NEVER have seen the "new hardware found" message come up. That's bad sign one. And the hardware device manager doesn't see it either (I think that would follow from no new hardware being detected..) Then I have run MAX 3.0 (also on the machine) and all it finds is this bizarre thing called "PXI System" under devices and interfaces. I also have an eight port serial card in this machine which MAX does see. I eventually removed both the Serial card and the PCI-6014 (daq card) and even after a restart the "PXI system" device or whatever STILL shows up under devices and interfaces... So I just don't know what that is?? Any help there would be appreciated.. So question one is what is "PXI system" likely referring to?? ..And to say more about it when you click the plus sign next to the "PXI system" entry it shows what appears to be a VISA resource name of PXIO::MEMACC. But again that shows up even with the card removed.
    Back to the PCI card seemingly not being recognized I also read somewhere that there could be issues with this card and the new version of NI-DAQ 7.0. So I uninstalled that version from the machine and put on the version that came with the PCI card, NI-DAQ 6.9.3. But same story... Windows doesn't see it and unless this PXI system is somehow referring to this PCI card (??) then MAX doesn't seem to be seeing it either... Any advice on how to get this card up and running or how to truly troubleshoot to see if the card was dead out of the box?? ...Something I have never had happen before and somehow I still think it is just some silliness on my part...
    Lastly, when I looked for the documentation for this card amont the long, long list of daq boards listed in the NI-DAQ software, nowhere did I find an entry for this PCI-6014 card. And I looked carefully. Does that mean I have a horribly old or outdated card??
    Any help would be appreciated... thanks...

    I am glad to hear that you got your card recognized correctly, too bad you have some bad PCI slots, though. The entry is shown by default and cannot be removed, but if you were to ever have a PXI chassis attached, your cards would be listed under this option, it is also where you would configure your controller and your chassis type. Also by default, there are no entries under this heading since you are not connected to a PXI system.
    Andrew Mierau
    Applications Engineer
    National Instruments

  • (PCI-6014) AI_VRead function returns only -5V~+5V ranges.

    After installing the PCI-6014 board, The Mesuremant Automation program work well between -10V~+10V range(Analog Input). But When I ran AIonePoint example, AI_VRead() function returns only -5V ~ +5V. It returns only 5V if I voltage more then 5V. In fact, I want to use this card in range -10V ~ + 10V. What can I do?
    Thank you for seeing this.

    You need to use a gain of -1.
    /* Nothing past this point should fail if the code is working as intended */

  • System won't boot with PCI-6014 installed

    I am using multiple PCI-6014 boards in several systems. One of the systems now fails to boot. By trial and error with parts from other sytems, I have determined that I have a PCI-6014 board which if I place it in any system, the system it is in will not boot. If I remove this particular PCI-6014 board, then the system will boot. These same systems will boot and operate properly with any of my other PCI-6014 boards installed as well.

    It appears that there is a problem with the board that prevents the systems from booting up. If you have tried the board in different slots and different machines with the same results, the next step is to request an RMA (Return Merchandise Authorization) for that board by calling our customer service number: 1-866-275-6964.
    -Alan A.

  • Motherboard manuals for older boards?

    Hi everybody.
    Does anybody know where I might be able to get hold of online or pdf forms of motherboard manuals for the following MSI boards?
    MS 6120 ver 1.1 BX3
    MS 6119 ver 1.1 BX2
    MS 6362
    I have been given these boards and they all appear to be server boards (dual CPU and SCSI sockets).  Trouble is I don't know any of the spec's hence my appeal :-)  I have tried looking in the downloads area but they appear to be older boards and no longer supported.  Is there anywhere I could get Windows drivers and possibly any BIOS updates too?
    Thank you.
    Kevan

    Quote from: nightmare99 on 13-February-08, 02:34:59
    Alot of people rated the 6119 as better than the 6163 Pro.
    I had a 6120 SCSI myself 
    I built several systems using 6163 pro's and a 6163 BX master's.
    I have owned many boards but the 6119 is my favorite.
    Its still running to this day using a P3 600 though a friend has it.
    I still have the original CPU a P2 450 I payed over $700 for when they first came out.
    Besides the board in my sig I still own a MSI-7051G K7N-GM2-LSR, my file server and a K7T turbo.
    I have only had one MSI board fail. My K7T turbo had the bad cap problem. I still have the board.
    Actually it did not fail it was running fine folding 24/7 and I thought it was time to blow the dust out of it.
    While cleaning it up I found all the larger caps were bulged and leaking. Its funny how it ran fine and never
    crashed folding 24/7 for months on end with bad caps.
    I was always going to recap it but never got around to it.
    Yup the good old days!

  • How can I convert a 0-50mA signal to 0-5 VDC for use by a PCI-6014 DAQ?

    I have a PCI-6014 DAQ card. I am trying to measure the output of a closed-loop current sensor, which has an output of 0-50mA. When I tried using a 100 ohm resistor as a load (to measure across the resistor to get a voltage input for the DAQ) I get an AC voltage reading! I do not know how to convert the AC Voltage to a varying DC voltage. Most AC-DC converters output a fixed DC voltage (3.3V, 12V, 15V, etc.). Can the PCI-6014 measure the current directly OR is there a method to measure the VARYING 0-5 volt AC voltage? Please be specific, if possible. Thanks in advance!

    Hello,
    PCI-6014 can measure an AC voltage directly. The Test Panels in MAX will show the peak voltage level of a signal, and not the root mean square (RMS) voltage. For example, if you measure the 120 VAC 60 Hz sinusoidal waveform that is available from a standard North American wall outlet, you will see a wave with a peak of about 170 V.
    The conversion between VRMS and Vo is VRMS = Vo/√2.
    You will need to determine whether you expect your AC signal to be in units RMS or peak-voltage and make the conversion, if necessary, using the formula above.
    -Arun V

  • Programmer Guide /Manual for PLD

    Dear all
    Is there any programmer guide /manual for PLD , or detailed material on PLD.
    Note :I have visited the page https://websmp207.sap-ag.de/smb/sbo/pld
    Regards,
    Ghazanfar

    hi,
    Check SDK & add on documents in
    Business One Knowledge centre under components,tools,FAQ's
    in below link.
    SAP Business One - SAP Developer Network
    Edited by: Jeyakanthan A on May 15, 2009 4:39 PM

  • Register Level Programmer Manual for M Series

    I am using M Series 6221 DAQ and unable to find the Register Level Programmer Manual for it. The E series manual is quite a detailed one (http://www.ni.com/pdf/manuals/341079b.pdf) , Can you please point me to a similar document for M series ..

    Hello ,
          I was directed to the same websites by the Application
    Engineer earlier too.
    I have been using the C++ code. The code is highly complex
    and without any comments. Its very difficult to reverse
    engineer it. Its a practice that code is written by refering
    the manual , instead of understanding the working from code.
    Its unbelivable that NI is selling this product without proper
    docuemntation.
    Anyways, My problem right now is :
    Info
    1. Using a x86 SBC based PC with ThreadX as operating system
    2. I want to use Port1 and Port2 as DI. Able to read from Port1 and Port2 by following the program.
    3. Channel 0 and Channel 1 as On Demand AI (RSE) for sensing 2 different parameters
       in the range of 0V to 10V. 
    4. Want to read a single sample from both the channels.
    5. Unable to read from Channel 0 and Channel 1 correctly yet.
    Questions:
    1. I am using aiex1.c program to acquire Analog signal .
        - numberOfChannels = 2 and numberOfSamples = 1
        - not using adcReset(board)
        - aiPersonalize (board, tMSeries::tAI_Output_Control::kAI_CONVERT_Output_SelectActive_High);
        - aiConfigureChannel (board, 
                                            Channel number 0 and 1 one after the other 
                                            0 gain
                                            tMSeries::tAI_Config_FIFO_Data::kAI_Config_PolarityBipolar,
                                            tMSeries::tAI_Config_FIFO_Data::kAI_Config_Channel_TypeRSE,
                                            Channel 1 is last channel )
       - As Is aiConvert (board,
                                     280,     // convert period divisor
                                     280,     // convert delay divisor
                                     kFalse);
      Any idea if i am not conguring or missing something ???
      As the acquired value i read is incorrect
    2. Suppose i configure Channel 0 and Channel 1, And want to acquire only from
       Channel 0 , What to do for it ?
    3. If acquisations happens from both the Channels , How do i know which data is acquired
        from the Channel 0 and Channel 1 in the FIFO ?
    4. Is there a method to read data directly from ADC instead of reading it from FIFO ?
    5. If there is input signal at Port0 (configured as DI), Can a interrupt be triggered ?
    6. How to make AI interrput based ?
    Thanks,
    Irfan

  • Eeprom address and caldacs model/address for pci-6014 and pci-6733

    I have one pci-6014 and one pci-6733.
    I need to transfer the calibration constants from eeprom to caldacs.
    I search the adrress of the constants in the eeprom and the model and address of che caldacs.
    Tanks

    Hello,
    It seems to be a common mode voltage or ground loop problem.
    When you are sourcing an output signal from your DAQ board, the signal is already grounded, it means that it has already a reference. If you measure this output with a measurement device, which has also a ground, the both ground potential are not necessary equal. This difference is the common mode voltage and influences your measurement (offset).
    Please check the following links to have more detail about grounded signal.
    http://zone.ni.com/devzone/conceptd.nsf/webmain/8D​907374C5E867F186256C640059F30C?opendocument
    http://digital.ni.com/worldwide/france.nsf/webtech​supp/0E6A8D5999CEE1AF8025683C0056A4B1?OpenDocument​&node=163080_f
    Best regards,
    Alexandre D
    National Instruments

  • Manual for iMovie?

    I'm new to the system and would like a manual to refer to for using iMovie. I find the videos not suitable for remembering every detail. Is there a manual available?

    These brief but informative tutorials on Apple.com may be helpful:
    http://www.apple.com/ilife/tutorials/#imovie
    Also, one of the helpful regulars who post on this board, Steve Mullen, has an excellent eBook, The Ins and Outs of Imovie 09:
    http://www.mindspring.com/~d-v-c/page1/page1.html

  • User manual for mainboard MS-6791

    Hello all,
    I've just purchased a used computer with the Micro Star MS-6791 mainboard in it. I've searched the MSI web site as well as the internet and have not been able to find the users manual for this mainboard. Does anyone have or can tell me where I can download the user manual for this mainboard?
    Thanks,
    Keith

    Thanks for the quick reply.
    This is a CableMart Inc house brand system. They do not offer any info or manual for the mainboard on their web site. The specs on this board is as follows:
    From eSupport Bios Agent tool
    BIOS Date: 05/31/04
    BIOS Type: Phoenix - AwardBIOS v6.00PG
    BIOS ID:   05/31/2004-SiS-648FX-6A7I5M4BC
    OEM Sign-On: Muse W6791SL2H V1.0B18 053104 12:04:47
    Chipset:   SiS 648 rev 81
    Superio:   Winbond 697HF rev 2 found at port 2Eh
    OS:        WinXP SP2
    CPU:       Intel(R) Pentium(R) 4 CPU 2400 Mhz MAX: 4000 Mhz
    BIOS ROM In Socket: Yes
    BIOS ROM Size:      256K
    Onboard chip shows SIS963L
    1- AGP
    3- PCI
    Onboard sound
    Onboard ethernet
    4- USB
    1- serial
    1- paralell
    Thanks,
    Keith

Maybe you are looking for

  • Safari won't open at all. Please help!

    Hi, lately my safari has been acting weird. It started when it won't click on links (nothing happens when I click them)and now safari itself won't open anything (no windows, no nothing) at all, so right now I'm on another computer. I went to safari h

  • Plsql_optimize_level = 3 and native compilation in SQL Developer?

    SQL Developer: Version 3.1.06 (Build MAIN-06.82) Oracle: 11gR2 OS: Ubuntu 10.10 Whenever I compile a PL/SQL unit in SQL Developer (using 'Compile' button) it is compiled with the following settings: PLSQL_OPTIMIZE_LEVEL = 2 PLSQL_CODE_TYPE = 'INTERPR

  • Search Help calling screen

    Hi Guys, please.. How can a Search Help implement a "CALL SCREEN" command? I have a problem in a ABAP WebDynpro app, apparently because the search help is calling a SCREEN from the program SAPLSZA1, and I have to undo this. It shouldn't call. This is

  • Ebj-QL dynamic IN LIST - is it possible?

    I need to create a finder method that takes in a dynamic list of string values and inserts it into a pre-defined ejb-QL statement. I am willing to build the comma separated string myself and pass it as a parameter - but what I have done so far doesn'

  • Sharing an External HD on network

    I am using an old G4 running 10.4.11 as a file server, I can access the Computer from both my Macbook Pro and a Vista laptop However I have yet to be able to see any external Hard drives that I plug in. I am testing my network usage with a 100GB exte