Reading of configuration of AEBS not successful...?

I'm quite surprised - first time no "plug&play", most likely a user problem...
Just tried to start configuring my new AEBS, connected BS to DSL modem and power - connected to iMac via WLAN, detected by software, started reading configuration of the base ....
But the reading of the configuration is never ending... what may be wrong? It just continues reading.... never giving any chance to set anything.
It tries to read the current configuration and never succeeds in showing the configuration, not to speak of a chance to set the configuration to my provider values etc.
Who may help?
Thanks a lot!

I have the same problem, but it doesn't work if I try an ethernet cable either. The first time I encountered this problem (only a day or two after purchase) , I did a hard reset, but a day later I am in the same situation. Any suggestions?
MacBook Core2 Duo 2.0   Mac OS X (10.4.8)   1 Gb SDRAM

Similar Messages

  • Airport Utility 5.2 and 5.2.1 cannot read /edit configuration of AEBS 7.2.1

    *THE PROBLEM ON my Mac:*
    I am using an ethernet connection directly to a brand new AEBS from:
    iMac Intel Core 2 Duo, 2BG RAM
    X 10.4.10
    airport turned off
    Airport Utility detects the base station but cannot read the configuration to edit and setup. And displays the following error:
    "An error occurred while reading the configuration.
    Please make sure your AirPort base station is plugged in and in range of your computer or connected via Ethernet and try again. (-5)"
    The AEBS does assign any machine connected via ethernet an IP address to allow internet access.
    *THE PROBLEM ON WINDOWS:*
    I have the nearly the same problem when using my Windows XP pro laptop connected via ethernet using Airport Utility for Windows ver 5.2 and 5.2.1
    Airport Utility detects the base station, but when attempting to access the configuration, the Error message is practically the same with a different error code:
    "An error occurred while trying to access the base station. Make sure your network connection is valid and try again. Error -6742
    *STEPS ATTEMPTED TO REMEDY THE PROBLEM (w/out success):*
    I have read the posts that say to turn off IPv6 on Mac, did that but with no success.
    Others did a simple hard reset on the AEBS, I tried that too.
    I've tried connecting to the AEBS directly with all other network devices (modem, other routers, etc) disconnected and turned off just incase there was some compatibly issue... no work. I even tried all the different ports.
    Any other suggestions would be appreciated. Can I walk into a Apple retail store and ask them to check the the AEBS to see if they can access the configuration?
    Just to be fair...
    (For people who have only read this post, turning off the IPv6 worked for some people, and just doing a hard reset for others).

    I finally figured it out. I had exactly the same problem when Airport Utility detected the base station but could not read the configuration to edit and setup, displaying the following error:
    "An error occurred while reading the configuration.
    Please make sure your AirPort base station is plugged in and in range of your computer or connected via Ethernet and try again. (-5)"
    I tried everything (Unfortuantely it is impossible to consult to an Apple genius around here). Even the hard reset didn't work. That is what I did: I pulled off the power cord, and put it back again WHILE HOLDING DOWN THE RESET BUTTON with a pin. Only after that the amber light went on twinkling, and I could access it via the Airport utility. All the settings were reset so I just had to reconfigure it. Hope it works for you too.

  • UWL COnfiguration(Connecters is not successfully connected)

    Hi,
    We are configuring UWL on portal.
    Folowing are the steps we followed for UWL configuration in terms for Portal as well as Backend.
    Backend:-
    1)SWU3 configuration is done.
    2)created UWL_Server with all the authorization.
    SAP_BC_BMT_WFM_UWL_END_USER
    SAP_BC_UWL_END_USER
    SAP_BC_UWL_SERVICE
    Portal:-
    1)Created one RFC through Visual Administrator
    2)Deployed one .SDA sonic connectors
    2)Created one system with SAP_R3_Workflow alias name but
    getting an error while testing connectors
    Test Connection with Connector
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure that Single Sign-On is configured correctly
    I believe by the time we donot configure the connectors sucessfully until we
    will not be able to register service in System_administration->system Configuration
    ->Universal Worklist.
    Please give you input that how we can manage to acivate the test connection of connectors.

    Hi Rishav,
    Please post this thread in portal related forum so that you will get appropriate replies..
    Rgds,
    Bharath

  • Unable to read Configuration of AEBS

    My AEBS n has worked for about 9 months, with any problems i've had being user error or windows/mac issues. Now i've got one that I am pretty much unable to find any information on. I am able to use the internet, print, and share information from my NAS to my MacBook, MBP, Mini, and WIn7 desktop. I am unable to access the AEBS from Finder, can see but not read the configuration from any machine (MB [snow leopard], MBP [leopard], Mini [leopard] all wireless, Win7 wired), and cannot use USB drives attached to the hub attached to the AEBS. I'm thinking that the AEBS isn't functioning properly, as opposed to some configuration issue, since the issue happened pretty much out of nowhere. My MB time machine uses a drive attached to the network, which it was no longer able to find, which is how i noticed the problem. Any help would be greatly appreciated.

    "Using the AirPort Utility, I can view the very basic details of the AEBS (IP, etc), but when I double click for more detailed information, it hangs on "Reading the AirPort Extreme configuration" (I have gotten at least two different error messages, -6753 is the only one I have written down). I get the same result from three different machines."
    Temporarily, connect an ethernet cable from your computer to one of the LAN<-> ports on the AEBS. Open AirPort Utility and see if you can read the device configuration that way.
    Likewise, you can do this individually for your other devices as well

  • Virtex6:Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings

    Hello,everyone.
    I am using virtex6 FPGA and trying to download mcs file to PROM and have failed.
    I download .bit file to FPGA and succeed.
    When i try to download .mcs file to PROM XCF128X-FTG64C(BPI Flash) and choose Slave SelectMAP Mode
    and the process is about 68% it fails.
    The message below the IMapct is as belows:
    done.
    PROGRESS_END - End Operation.
    Elapsed time =      0 sec.
    // *** BATCH CMD : identifyMPM
    // *** BATCH CMD : assignFile -p 1 -file "C:/Users/Administrator/Desktop/TEST/LED/led.bit"
    '1': Loading file 'C:/Users/Administrator/Desktop/TEST/LED/led.bit' ...
    done.
    INFO:iMPACT:2257 - Startup Clock has been changed to 'JtagClk' in the bitstream stored in memory,
    but the original bitstream file remains unchanged.
    UserID read from the bitstream file = 0xFFFFFFFF.
    INFO:iMPACT:501 - '1': Added Device xc6vlx240t successfully.
    INFO:iMPACT - Current time: 2014/3/13 8:48:14
    // *** BATCH CMD : Program -p 1
    PROGRESS_START - Starting Operation.
    Maximum TCK operating frequency for this device chain: 66000000.
    Validating chain...
    Boundary-scan chain validated successfully.
    INFO:iMPACT - 1: Over-temperature condition detected! [ 230.52C >  120.00C]
    1: Device Temperature: Current Reading:  230.52 C, Max. Reading:  230.52 C
    1: VCCINT Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    1: VCCAUX Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    '1': Programming device...
     Match_cycle = NoWait.
    Match cycle: NoWait
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    done.
    INFO:iMPACT:2219 - Status register values:
    INFO:iMPACT - 0011 1111 0111 1110 0100 1011 1100 0000
    INFO:iMPACT:579 - '1': Completed downloading bit file to device.
    INFO:iMPACT:188 - '1': Programming completed successfully.
     Match_cycle = NoWait.
    Match cycle: NoWait
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    INFO:iMPACT - '1': Checking done pin....done.
    '1': Programmed successfully.
    PROGRESS_END - End Operation.
    Elapsed time =     23 sec.
    Selected part: XCF128X
    // *** BATCH CMD : attachflash -position 1 -bpi "XCF128X"
    // *** BATCH CMD : assignfiletoattachedflash -position 1 -file "C:/Users/Administrator/Desktop/TEST/LED/leda.mcs"
    INFO:iMPACT - Current time: 2014/3/13 8:49:32
    // *** BATCH CMD : Program -p 1 -dataWidth 16 -rs1 NONE -rs0 NONE -bpionly -e -v -loadfpga
    PROGRESS_START - Starting Operation.
    Maximum TCK operating frequency for this device chain: 66000000.
    Validating chain...
    Boundary-scan chain validated successfully.
    INFO:iMPACT - 1: Over-temperature condition detected! [ 230.52C >  120.00C]
    1: Device Temperature: Current Reading:  230.52 C, Max. Reading:  230.52 C
    1: VCCINT Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    1: VCCAUX Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    '1': BPI access core not detected. BPI access core will be downloaded to the device to enable operations.
    INFO:iMPACT - Downloading core file D:/Xilinx/14.3/ISE_DS/ISE/virtex6/data/xc6vlx240t_jbpi.cor.
    '1': Downloading core...
     Match_cycle = NoWait.
    Match cycle: NoWait
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    done.
    INFO:iMPACT:2219 - Status register values:
    INFO:iMPACT - 0011 1111 0111 1110 0100 1011 1100 0000
    INFO:iMPACT:2492 - '1': Completed downloading core to device.
    Current cable speed is set to 6.000 Mhz.
    Cable speed is default to 3Mhz or lower for BPI operations.
    Current cable speed is set to 3.000 Mhz.
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    Populating BPI common flash interface ...
    Common Flash Interface Information Query completed successfully.
    INFO:iMPACT - Common Flash Interface Information from Device:
    INFO:iMPACT - Verification string:  51 52 59
    INFO:iMPACT - Manufacturer ID:         49
    INFO:iMPACT - Vendor ID:              01
    INFO:iMPACT - Device Code:            18
    Setting Flash Control Pins ...
    Using x16 mode ...
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    '1': Erasing device...
    '1': Start address = 0x00000000, End address = 0x008CE03B.
    done.
    '1': Erasure completed successfully.
    Setting Flash Control Pins ...
    Using x16 mode ...
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    INFO:iMPACT - Using Word Programming.
    '1': Programming Flash.
    done.
    Setting Flash Control Pins ...
    '1': Flash Programming completed successfully.
    Using x16 mode ...
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    '1': Reading device contents...
    done.
    '1': Verification completed.
    Setting Flash Control Pins ...
    Current cable speed is resumed to 6.000 Mhz.
    '1': Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings.
    `Elapsed time =    814 sec.
    and i find many people have met the same thing. But they are spartan  series FPGA and i try to low the Resistances of Mode pins,M0 M1 and M2, but the problem does not been solved.
    I have read the status Registers and find there is an over-temperature state 
    and in Impact i could not readback the registers. It is strange.
    I am anxious about this problem and have not solved it yet
    What reasons may it be?
    Hope for your answer, thank you

    Hi~I want to know if you solve the configuration problem for virtex-6?
    As I encounter the  same configuration problem, I want to consult  you with some question.
    Can I have your email?
    gszakacs wrote:
    I have measured the VCCINT and find it is 1.0V, not 2.997V;
    That is not at all surprising.  I always assumed the problem is with reading the XADC (system monitor) block and not with the voltage or temperature.
    my Reference board is ML605
    That would have been nice to know at the beginning...
    It seems that you have selected the correct mode, assuming your jumpers are set as required in the ML605 Hardware User's Guide.  See table 1-27, table 1-33 and the note below it about switch S1.
    I'm not that familiar with the details of this reference design, but it may be that the slave SelectMap circuitry requires a reset or power cycle to actually configure the FPGA.  Have you tried power-cycling to see if the FPGA boots from the flash?
    I'd also suggest that you select the V6 in the JTAG chain view, then go to the debug menu of Impact and select Read Device Status (this is from memory, but it's something like that).  That will not only show the bits of the configuration status register, but also describe what each bit means.  Among other things you can check the state of the FPGA's configuration logic and the Mode pins.
     

  • I can not open Firefox. Keep getting the error message "Failed to read the configuration file. Please contact your system administrator." What do I do?

    I can not open Firefox. I keep getting the message "Failed to read the configuration file. Please contact your system administrator." I have tried uninstalling Firefox and then reinstalling it but without success. What should I do?

    Which Fx version? When you uninstalled Fx, did you <b>reboot</b> computer before reinstall?
    Also, check for / delete any leftover files in the Fx programs install folders, before reinstall?
    Is your profile in the default location or custom location?
    Have you tried creating a <u>new, <b>completely</b> clean profile</u> - to test (then make sure to select that profile to start Fx - from the Profile Manager)? (no addons or plugins installed).
    Does the user acct (that Fx fails under) have access ("rights") to all locations - especially for Fx profiles location?

  • Configuration data download to FPGA was not successful.

    I have designed a board with the Spartan 6 LX9 TQFP144 Package.
    I am able to load a bitstream to the device with the digilent HS-2. However the fpga can not selfconfigure from
    the attached SPI Flash.
    Here is the console output from iMPACT:
    GUI --- Auto connect to cable...
    INFO:iMPACT - Digilent Plugin: Plugin Version: 2.4.4
    INFO:iMPACT - Digilent Plugin: found 1 device(s).
    INFO:iMPACT - Digilent Plugin: opening device: "JtagHs2", SN:210249983579
    INFO:iMPACT - Digilent Plugin: User Name: JtagHs2
    INFO:iMPACT - Digilent Plugin: Product Name: Digilent JTAG-HS2
    INFO:iMPACT - Digilent Plugin: Serial Number: 210249983579
    INFO:iMPACT - Digilent Plugin: Product ID: 30900152
    INFO:iMPACT - Digilent Plugin: Firmware Version: 0109
    INFO:iMPACT - Digilent Plugin: JTAG Port Number: 0
    INFO:iMPACT - Digilent Plugin: JTAG Clock Frequency: 10000000 Hz
    Attempting to identify devices in the boundary-scan chain configuration...
    INFO:iMPACT - Current time: 27.07.2015 16:19:26
    PROGRESS_START - Starting Operation.
    Identifying chain contents...'0': : Manufacturer's ID = Xilinx xc6slx9, Version : 2
    INFO:iMPACT:1777 -
    Reading C:/Xilinx/ISE/14.7/ISE_DS/ISE/spartan6/data/xc6slx9.bsd...
    INFO:iMPACT:501 - '1': Added Device xc6slx9 successfully.
    done.
    PROGRESS_END - End Operation.
    Elapsed time =      0 sec.
    Selected part: N25Q128
    Unprotect sectors: FALSE
    INFO:iMPACT - Current time: 27.07.2015 16:20:19
    PROGRESS_START - Starting Operation.
    Maximum TCK operating frequency for this device chain: 25000000.
    Validating chain...
    Boundary-scan chain validated successfully.
    '1': SPI access core not detected. SPI access core will be downloaded to the device to enable operations.
    INFO:iMPACT - Downloading core file C:/Xilinx/ISE/14.7/ISE_DS/ISE/spartan6/data/xc6slx9_spi.cor.
    '1': Downloading core...
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    done.
    '1': Reading status register contents...
    INFO:iMPACT:2219 - Status register values:
    INFO:iMPACT - 0011 1100 1110 1100
    INFO:iMPACT:2492 - '1': Completed downloading core to device.
    '1': IDCODE is '20ba18' (in hex).
    '1': ID Check passed.
     '1': IDCODE is '20ba18' (in hex).
    '1': ID Check passed.
     '1': Erasing Device.
    '1': Using Sector Erase.
    '1': Programming Flash.
    '1': Reading device contents...
    done.
    '1': Verification completed.
    '1':Programming in x4 mode.
    '1': Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings.
    INFO:iMPACT - '1': Flash was not programmed successfully.
    PROGRESS_END - End Operation.
    Elapsed time =     78 sec.
    If i read that correctly Data was written to the Flash but the fpga was not able to configure from that data.
    Done-pin is connected to 3.3V via a 470 Ohms Resisor.
    The Flash is a N25Q128A13ESE40G, Datasheet here: http://www.farnell.com/datasheets/1674445.pdf
    I can perform a readback, checksum and an erase.
    If i do a read device status this is the console output:
    INFO:iMPACT - Current time: 27.07.2015 16:36:27
    Maximum TCK operating frequency for this device chain: 25000000.
    Validating chain...
    Boundary-scan chain validated successfully.
    '1': IDCODE is '20ba18' (in hex).
    '1': ID Check passed.
     '1': IDCODE is '20ba18' (in hex).
    '1': ID Check passed.
     '1': IDCODE is '20ba18' (in hex).
    '1': ID Check passed.
     INFO:iMPACT - '1': Reloading FPGA configuration data stored in flash...
    INFO:iMPACT:182 - done.
    On the Flash side I have pulled s# and Hold up to 3.3V with 100k Resistors.
    Can someone help me to find the problem?

    So does the FPGA try to read the SPI flash when it boots ?
    out with scope, probe the clock and the data , see if you can see it streamig out when you boot.
    If so, then one other thing I see wrong a few times is data path of the SPI, single bit or 4 bits of data.
        you have to make certain the bit file was created in the same width as the fgpa is expecting,
          In ISE I think its in Impact where you make the SPI flash file and specify this .
     

  • V5 in BPI Mode " Configuration data download to FPGA was not successful. DONE did not go high,"

    Hello,everyone.
    I am using virtex5 XC5VLX155 FPGA and trying to download mcs file to BPI flash and have failed.
    The flash is JS28F512P30E. The iMpact version is 14.7. 
    FPGA's VCCINT is 1.0V, VCCAUX is 2.5V. VCCO is 3.3V.
    M[2:0] is 010 in Master BPI.  Ican  program FPGA through JTAG. The FPGA_DONE pin 's  LED can always flash.
    The error is shown as below. the full  IMPACT console log and the SCHEMATIC_ FLASH are in the attachment.
    Using x16 mode ...
    Setting Flash Control Pins ...
    '1': Erasing device...
    '1': Start address = 0x00000000, End address = 0x004E4AFF.
    done.
    '1': Erasure completed successfully.
    Using x16 mode ...
    Setting Flash Control Pins ...
    INFO:iMPACT - Using Word Programming.
    '1': Programming Flash.
    done.
    '1': Flash Programming completed successfully.
    '1': Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings.
    PROGRESS_END - End Operation.
    Elapsed time =    692 sec.
    Hope everyone give more advices. Thank you.
     

    Thank you very much!
    I can read ack the mcs file, but the file is much bigger than the original mcs file.
    The flash datasheet is in the attachment.
    I want to use the Master BPI mode. In BPI_UP, the address starts at 0 and increments by 1 until the DONE pin is
    asserted. I do not know the difference between the BPI_UP and BPI_DOWN.
    ps:  The R61,R62 and R63 are not weld on the board. The ADV pin is tie to VSS .
     

  • How can I configure ReFS to NOT fail read operations when a checksum error is detected (on non-Storage-Spaces volumes where data integrity streams are enabled)?

    According to William Stanek, in his Windows Server 2012 R2 Inside Out: Configuration, Storage & Essentials book, this is apparently possible: (pg. 615 - here it is on Google Books: https://books.google.ca/books?id=0IyfBAAAQBAJ&pg=PT819&lpg=PT819&dq=read+operation )
        Integrity can be enabled when the system is not running on Storage Spaces. When
        integrity is enabled and ReFS detects a checksum mismatch, ReFS logs an event and
        fails the read operation by default. If you don’t want the read operation to fail, you
        can configure ReFS to continue with the read operation. A related event will be logged
        regardless.
    So then how do I configure it to do that???
    (And just to make it super-clear, I'm NOT using Storage Spaces, so there is no redundancy via mirroring/parity, and I'm not expecting any file repair - just detection of corruption. It's just a basic volume formatted with ReFS and
    with integrity streams enabled, via format E: /fs:ReFS /i:enabled
    For those who want more details, here's the situation: 
    I try to perform a read operation on a file with corrupted data (purposely done for testing using a low-level disk editor), I get a the following error message:
    And an event ID 133 from ReFSv1 gets logged in the System log:
    Clicking "Try Again" just brings up the same message, and clicking "Skip" skips the operation entirely.
    This is indeed the correct default behaviour.
    What I want instead is for the read operation to be allowed to complete, with corrupt data and all, and ONLY for the event to be logged. And according to William Stanek, this is supposed to be configurable somewhere - and after hours of searching, I haven't
    been able to find anything.

    Hi Tommy,
    >>How can I configure ReFS to NOT fail read operations when a checksum error is detected
    We can use PowerShell command Set-FileIntegrity to configure this. The specific parameter for controlling this behavior is
    -Enforce <Boolean>which indicates whether to enable blocking access to a file if integrity streams do not match the data.  
    Regarding this point, the following article can be referred to as reference.
    Set-FileIntegrity
    https://technet.microsoft.com/en-us/library/jj218351.aspx
    Best regards,
    Frank Shen
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • SQL Server 2005 Database Mail - Mail configuration information could not be read from the database.

    I'm trying to setup Database Mail and send a test message, but it's not working.
    I've done several step-by-steps and all and I can't get it to work. Also checked several posts in this forum but none helped. I think it used to work before (2 months ago) but we had to turn it off.
    I've enabled it in Surface Configuration, have tried recreating all profiles, restarted SQL Agent, checked version mismatch...
    I check the Database Mail and I get the following message:
    Log Database Mail (Database Mail Log)
    Log ID 152
    Process ID 7684
    Last Modified 3/14/2013 6:49:58 PM
    Last Modified By SPEEDLING\sqlservice
    Message
    1) Exception Information
    ===================
    Exception Type: Microsoft.SqlServer.Management.SqlIMail.Server.Common.BaseException
    Message: Mail configuration information could not be read from the database.
    Data: System.Collections.ListDictionaryInternal
    TargetSite: Microsoft.SqlServer.Management.SqlIMail.Server.Objects.Account GetAccount(Int32)
    HelpLink: NULL
    Source: DatabaseMailEngine
    StackTrace Information
    ===================
       at Microsoft.SqlServer.Management.SqlIMail.Server.DataAccess.DataAccessAdapter.GetAccount(Int32 accountID)
       at Microsoft.SqlServer.Management.SqlIMail.Server.Controller.CommandFactory.CreateSendMailCommand(DBSession dbSession)
       at Microsoft.SqlServer.Management.SqlIMail.Server.Controller.CommandRunner.Run(DBSession db)
       at Microsoft.SqlServer.Management.SqlIMail.IMailProcess.ThreadCallBack.MailOperation(Object o)
    2) Exception Information
    ===================
    Exception Type: System.IndexOutOfRangeException
    Message: timeout
    Data: System.Collections.ListDictionaryInternal
    TargetSite: Int32 GetOrdinal(System.String)
    HelpLink: NULL
    Source: System.Data
    StackTrace Information
    ===================
       at System.Data.ProviderBase.FieldNameLookup.GetOrdinal(String fieldName)
       at System.Data.SqlClient.SqlDataReader.GetOrdinal(String name)
       at System.Data.SqlClient.SqlDataReader.get_Item(String name)
       at Microsoft.SqlServer.Management.SqlIMail.Server.DataAccess.DataAccessAdapter.GetAccount(Int32 accountID)

    I'm trying to setup Database Mail and send a test message, but it's not working.
    I've done several step-by-steps and all and I can't get it to work. Also checked several posts in this forum but none helped. I think it used to work before (2 months ago) but we had to turn it off.
    I've enabled it in Surface Configuration, have tried recreating all profiles, restarted SQL Agent, checked version mismatch...
    I check the Database Mail and I get the following message:
    Log
    Database Mail (Database Mail Log)
    Log ID
    152
    Process ID
    7684
    Last Modified
    3/14/2013 6:49:58 PM
    Last Modified By
    SPEEDLING\sqlservice
    Message
    1) Exception Information
    ===================
    Exception Type: Microsoft.SqlServer.Management.SqlIMail.Server.Common.BaseException
    Message: Mail configuration information could not be read from the database.
    Data: System.Collections.ListDictionaryInternal
    TargetSite: Microsoft.SqlServer.Management.SqlIMail.Server.Objects.Account GetAccount(Int32)
    HelpLink: NULL
    Source: DatabaseMailEngine
    StackTrace Information
    ===================
       at Microsoft.SqlServer.Management.SqlIMail.Server.DataAccess.DataAccessAdapter.GetAccount(Int32 accountID)
       at Microsoft.SqlServer.Management.SqlIMail.Server.Controller.CommandFactory.CreateSendMailCommand(DBSession
    dbSession)
       at Microsoft.SqlServer.Management.SqlIMail.Server.Controller.CommandRunner.Run(DBSession db)
       at Microsoft.SqlServer.Management.SqlIMail.IMailProcess.ThreadCallBack.MailOperation(Object o)
    2) Exception Information
    ===================
    Exception Type: System.IndexOutOfRangeException
    Message: timeout
    Data: System.Collections.ListDictionaryInternal
    TargetSite: Int32 GetOrdinal(System.String)
    HelpLink: NULL
    Source: System.Data
    StackTrace Information
    ===================
       at System.Data.ProviderBase.FieldNameLookup.GetOrdinal(String fieldName)
       at System.Data.SqlClient.SqlDataReader.GetOrdinal(String name)
       at System.Data.SqlClient.SqlDataReader.get_Item(String name)
       at Microsoft.SqlServer.Management.SqlIMail.Server.DataAccess.DataAccessAdapter.GetAccount(Int32 accountID)

  • Subprocess 33 was not successful. Master cannot read return value from S 33

    Hi All,
    We are on BI 7.0 SP 19.
    We have submitted a planning sequence in the background with automatic packaging.
    The planning sequence has two steps:
    Step 1. Z_PLNG_FUNCTION1
    Step 2. Z_PLNG_FUNCTION2
    As per automatic packaging, the system chose 0ACCOUNT for packaging.
    When submitted, each step has been submitted to 30 packages as 30 subprocesses.
    For Step 1, the log shows that All subprocesses  executed.
    For Step 2, the log shows that the subprocess 33 and 58 failed, which means subprocess #3, and # 28 for the step 2 as the subprocess is numbered in the log in combination with step 1.
    The messages in the log for the failed subprocesses are as follows:
    @5C\QError@     Subprocess 33 was not successful
    @5C\QError@     Master cannot read return value from subprocess 33
    @5C\QError@     Subprocess 58 was not successful
    @5C\QError@     Master cannot read return value from subprocess 58
    Our question is on how to find the exact cause of the subprocess failure.
    I tried to look for the details on the error messages, they have been not helpful.
    What is meant by 'Master cannot read return value from subprocess' and how to get the exact cause of the failure?
    Thanks in advance,
    Best Regards,
    - Shashi

    Shashi,
    implement the following notes and check again:1368659, 1525723, 1532061.
    Regards,
    Marc
    SAP Techology RIG

  • When plugging in an iPad in Apple Configurator, it is not being read under USB Connected so I can't update it.  Any ideas on how to get the system to read the iPad?

    When plugging in an iPad in Apple Configurator, it is not being read under USB Connected so I can't update it.  The iPhoto window opens up and reads the photos on the iPad, so it is connecting to the computer.  Earlier today I wasn't having any problems.  I have shut down the iPad and the computer and started over, but that didn't help.  Any ideas on how to get the system to read the iPad so I can update the apps on it?

    Hi, is the problem just to update your apps on your iPad? Here is what you should check. Is the iTunes on your computer updated to the latest version? Does your iPad needs to be updated? Do you have enough storage on your iPad to do the update? On your device is your iCloud back up checked?
    Go to Settings - iCloud - Backup/Storage - see if its checked, and try unchecking it before connecting it to the computer.
    Please let me know if you need any further assistance.

  • Firefox does not open, but instead gives the error message, "Failed to read the configuration file." It has worked in the past, but not now.

    Firefox does not open, but instead gives the error message, "Failed to read the configuration file." It has worked in the past, but not now.
    I REINSTALL 10 TIMES SO DON'T TELL ME THAT!!!
    I'm piss because i need firefox working again so i can finish reseaching my speech in 5 days.

    Which files do you have in the defaults\pref folder in the Firefox program folder?
    *(32 bit Windows) "C:\Program Files\Mozilla Firefox\"
    *(64 bit Windows) "C:\Program Files (x86)\Mozilla Firefox\"
    See also "Other solutions":
    *http://kb.mozillazine.org/Preferences_not_saved
    Do a clean reinstall and delete the Firefox program folder before (re)installing a fresh copy of the current Firefox release.
    Download a fresh Firefox copy and save the file to the desktop.
    *Firefox 22.0: http://www.mozilla.org/en-US/firefox/all.html
    Uninstall your current Firefox version, if possible, to cleanup the Windows registry and settings in security software.
    *Do NOT remove personal data when you uninstall your current Firefox version, because all profile folders will be removed and you lose personal data like bookmarks and passwords from profiles of other Firefox versions.
    Remove the Firefox program folder before installing that newly downloaded copy of the Firefox installer.
    *(32 bit Windows) "C:\Program Files\Mozilla Firefox\"
    *(64 bit Windows) "C:\Program Files (x86)\Mozilla Firefox\"
    *It is important to delete the Firefox program folder to remove all the files and make sure that there are no problems with files that were leftover after uninstalling.
    *http://kb.mozillazine.org/Uninstalling_Firefox
    Your bookmarks and other personal data are stored in the Firefox profile folder and won't be affected by an uninstall and (re)install, but make sure that "remove personal data" is NOT selected when you uninstall Firefox.
    *http://kb.mozillazine.org/Profile_folder_-_Firefox
    *http://kb.mozillazine.org/Profile_backup
    *http://kb.mozillazine.org/Standard_diagnostic_-_Firefox#Clean_reinstall

  • The configuration file did not contain well formed AppV configuration XML - When using Office 2013 ODT package

    All,
    I'm experiencing an issue where when using the Office 2013 package pulled down from ODT, that if I try to change the locations of either InfoPath Filler 2013 or Publisher 2013 from the default of Microsoft Office 2013 then I receive the message "The
    configuration file did not contain well formed AppV configuration XML. Please check the management server event log for more information". If I check Applications and Services\Microsoft\AppV\Server-Management\Admin the error displayed there is "An
    error was encountered parsing dynamic configuration file '0'. However I am able to change the shortcut location for all other applications except the above 2. I've tried redownloading the files using the ODT and also changing the version number (so far I've
    tried both the 15.0.4631.1002 and 15.0.4659.1001 with the same result).
    As all I'm interested in so far is having a package which contains Visio and Project I've tried following the article to exclude all the other Office elements:
    http://technet.microsoft.com/library/jj219426(v=office.15).aspx#BKMK_ExcludeAppElement. However the package looks to be the same and when I load it into the management console all the options and elements to Office 2013 are available like they were before
    when I hadn't set the exclude tags so I'm not sure whether the ExcludeApp parameters actually work correctly.
    This then brings me onto the 3rd issue I've experienced. I have a group for the Visio users and I've set custom security for them to have Visio delivered to them but not Project and then a seperate group for just Project users who will have Project delivered
    to them but not have Visio. When testing this sometimes seems to work but other times it seems to trip out and a user just in the Project or Visio group will get all of the Office 2013 applications and under the default location of Microsoft Office 2013. When
    trying to spot correlation with this it appears random and can happen to any user on any device. We have sequenced a few applications ourselves where different parts are needed for different users and we have successfully managed this using different security
    groups for different applications, just as I'm trying here with Office 2013.
    Has anyone else experienced the issue with the "did not contain well formed XML" as at the start of the post and how were you able to resolve this? Also has anyone any advice on how to troubleshoot the issue with the security seeming to trip out
    and publish all applications within a package to a user regardless of whether they are in the correct group or not?
    The management / publishing servers are 5.0.1224.0 which is SP1 HF4 and the clients are on SP2 HF5.
    Thanks

    Nicke,
    The config files are UTF-8. I did find the same article as yourself, however when searching for the value ‘TakeoverExtensionPointsFrom46=’ within either of the configuration.xml files that text isn’t found.
    No sinister reason not to share the file used, just it’s the same structure as referenced in the article:
    http://technet.microsoft.com/en-us/library/dn745895(v=office.15).aspx. The only difference being that I’m using ProPlusVolume and I’ve set a version number (which is the October
    2014 update). I’ve even looked to follow the above example as closely as possible in just using the ExcludeApp ID of Access and InfoPath, just to try and prove the process. However I still get the usual full package. The version of the Click-to-Run setup.exe
    I’m using is 15.0.4623.1001, so later than the version specified at the end of that article which is 15.0.4619.1000. Where can I expect to see the elements excluded? Will it be when loading the package into the management console or would it just not appear
    on the machine when delivered?
    <Configuration>
      <Add SourcePath="C:\OfficeDeploymentToolV2" Version="15.0.4659.1001" OfficeClientEdition="32">
        <Product ID="ProPlusVolume">
          <Language ID="en-us" />
    <ExcludeApp ID="Access" />
    <ExcludeApp ID="InfoPath" />
        </Product>
      </Add>
    </Configuration>
    3). We’ve not used global publishing in our environment yet so I will try that. I’ve set both GlobalRefreshEnabled and GlobalRefreshOnLogon to True and when using the command Get-AppvPublishingServer on the client I’m testing with I can see this is pulled
    through correctly. I’ve also added the client name to the AD group used to grant access to the package and it is published. However nothing is pulling through onto the Client, so are there any steps I’ve missed or misinterpreted when looking to set this up?
    I guess the global publishing is there to keep in with licensing for Office being per device? On a slight aside, as Windows licensing is being changed to allow per user licensing
    http://www.zdnet.com/microsoft-to-make-per-user-windows-licensing-available-to-enterprise-customers-7000035401/ does anyone know if there are any plans to allow for Office / Project / Visio licenses to go per user as well? We’re a volume license customer
    rather than subscription based so I think a lot of the options to selectively deploy Visio and Project are excluded for us.
    Dan,
    Ok that explains why the security could be tripping out then and leading to this result. As above I’ll try with global publishing and see how I get on.
     From what I’ve read / watched  I think only one Office 2013 package can be published to a machine, so we would be unable to have a separate package for Visio and a separate package for Project and then attempt to deliver
    them both together. If a user wanted both Project and Visio then I guess we’d need to have a combined Project and Visio package to cover than scenario, but then 2 more separate Project and Visio packages for those who would only want either Project and Visio
    (I think).
    The scenario we’re looking at is to see whether we are able to deliver Project and / or Visio to different users through an AppV package and this will then cover users on XenApp or on fat clients. Only a small proportion of our
    users will need access to Project and / or Visio so therefore we’d only have a small amount of Project and Visio licenses.
    However from what I’ve tested up to this point and from what I’ve picked up from Forum posts / watched on TechEd sessions is that as publishing is Global and is unable to use different security groups for different elements of the
    suite, then using Office through AppV is only suitable if you will be delivering the whole suite (including Project and Visio) to all of your users. So in a scenario where you’d only want certain elements to be delivered to a handful of users then you’d need
    to keep with traditional ESD methods to have this installed onto fat clients and steer clear of XenApp. If wanting to install to XenApp then a lockdown tool like AppSense or AppLocker would also need to be brought into the equation.
    Is my understanding above correct or have I missed some options / methods?
    If the full Office package is always delivered but a company only has Office licenses and no Project and Visio licenses for all its users, how do they stop Project and Visio being delivered and being available? Or again if you have
    this use case is the AppV method one which will be unsuitable?
    Thanks

  • Configuring Device - Device not reachable

    My new Envy 4500 _IS_ on my network.
    My new MacBook Pro _IS_  on my network.
    I get to the configuration step and all looks good until I get the response below:
    "Configuring Device
    0 Select Device
    0 Confirm Wreless Settings
    O Select Network
    Configuring Device
    Configuration Results
    Device Not Reachable
    Th) wireless network settings were successfully downloaded to your device. However, your Mac
    was unable to locate the device on the network.
    Please make sure that:
    • Your Mac is connected to a wired or wireless network that has access to your device.
    • Your device is connected to the wireless network "AC Network".
    Fomore information online, visithftp://www.hp.com/o/wirelessprinting"
    This is the second HP printer that I am trying to configure that is doing the same darn thing.  I thought the first one was faulty, so I exchanged for a slightly different printer.  This one has a control screen, so I KNOW that it's on the network.  And I KNOW my computer is on the network, or I wouldn't be able to write this.
    But they refuse to talk with each other.  SO frustrating.  I'm ready to give up on HP.
    Joe
    This question was solved.
    View Solution.

    Found the problem.  HP printers don't support AC Wifi.  That would have been nice to know before I wasted 4 hours on 2 printers......

Maybe you are looking for