Receiving the error message while executing the Real Time DTP

Hi,
I am receiving the error message while executing the Real time DTP for Billing data.
Error Message - Record filtered in advance as error records with the same key exist     RSM2     722
When I check the logs below is the message I am able to see. Can someone suggest as how to proceed further.
Diagnosis
The existing DTP requires a serialized update because fields are updated
non-commutatively during the processing run (for example, MOVE).
Therefore all new data records that have the same semantic key as
incorrect records that have not yet been corrected in earlier requests
or earlier data packages of the same request, are filtered out after the
extraction in a special step. In this way the system ensures that
incorrect data records are not repeated for your changes, which may not
contain errors themselves.
System Response
The data record is not updated but is written to an error stack.
Procedure
Procedure
Correct all incorrect data records and update them using an error DTP.
Procedure for System Administration
I checked the error stack and corrected the entries and let me know as how to proceed further. I am unable to execute the Error DTP as its not allowing me to edit and has only display options.
Regards,
Ram

Hi Arvindh,
Its  write optimized DSO.. there is no option to generate SIDs.
Hi Kiran,
I checked the link u sent me. Here the main issue is..The function module is standard  and its not allowing me  to do enhancement  point..
Any idea in using Badi's??
Thanks all...

Similar Messages

  • Bypass the error messages while opening the Web Analysis 9.3.1 Report

    I am using WA 9.3.1 to create a few reports. The login users will have some essbase meta-read security filters to restrict the access into certain regions and entities.
    For example:
    user a has the meta-read and read access of @idescendants (east);
    user b has the meta-read and read access of @idescendants (west);
    user c has all the accesses
    However, in the first start-up page (Web Analysis 9.3.1 dashboard), I have a dashboard which contains all the regions access. When user a login, he shall only see his own dashboard (speedometers, etc.).
    Currently the user login will get some error messages (such as "loading document produce error", etc). I wonder whether we can set the message level in Web Analysis so that there is no such error message while the user is opening the reports.
    Thanks

    Karen,
    Thanks for the reply.
    I have checked my Web Analysis report, and I still have the error message of "Error Occur while opening document. Document ID = {0}" while using the some user id to login.
    In my Web Analysis database connection preference, my setting is "user the user id and password". I have verified this (when I use "user a" to login, and in essbase connection, i can see the session with "user a").
    In the WA report, however, I use the multiple-level combo box, so that it can give me different levels of entities, for example, the top level is all regions, the 2nd level is east/west/south/ ec, and the next level is cities, and so on. And if "user a" login, he will be able to see the all regions and east, and then east cities (of course, if he select all regions, there will be no data available).
    Do you think this multiple level combo boxes can be the cause of this error message?
    Thanks a lot

  • Receiving SQL Error: INTERNAL_ERROR  while executing the query

    Dear All,
    I am receiving the below error while executing a query.
    SQL Error: INTERNAL_ERROR
    Diagnosis
    The database system registered an SQL error. As available, the error number and a description are included in the short text. Possible causes for SQL errors include:
    Overflow of database objects such as buffers, temporary tablespaces, rollback segments or data containers/tablespaces.
    ->These problems can generally be eliminated by system administrators.
    Missing generated database objects such as tables or views based on inconsistent or inactive InfoCubes or InfoObjects. Examples of this include the view of the fact table for an InfoCube or the attribute SID table (X/Y table) of a characteristic.
    -> These problems can generally be eliminated by a BW administrator.
    SQL requests with incorrect content.
    -> Problems of this type are generally programming errors.
    System Response
    Procedure
    Contact your system administrator.
    Procedure for System Administration
    If there is no error description, look for one in the reference from the database producer.
    Decide on the correct category for the SQL error and check if it can be eliminated. Generally the error can also be found in the syslog (transaction sm21). From there, transactions sm51 and sm50, the developer's trace log of the work process can be determined and the erroneous statement can be viewed in the log. This procedure is described in SAP Note 568768.
    Notification Number DBMAN 257 
    I verified the table spaces and also done RSRV Repair of InfoObjects and InfoCubes and didnt find any error. But I am receiving this error for one particular month and remaining months are executing fine. Any ideas why i am receiving this error.
    Regards
    Ravi Y

    OSS Note 1305568:
    Symptom
    A data mart query that
    you want to execute within a data transfer process (DTP), for example, terminates with the
    SQL error -1013 "Too many order columns".
    The following is displayed in the monitor log of the data transfer process:
    Error while extracting from source xxxxxx (type InfoProvider)
    Message number RSBK 242
    Exception CX_SQL_EXCEPTION occurred (program:
    CL_SQL_STATEMENT==============CP, include:
    CL_SQL_STATEMENT==============CM004, line: 32).
    Message number RS_EXCEPTION 000
    SQL error: POS(3306) Too many order columns
    Message number DBMAN 257
    Error reading the data of InfoProvider xxxxxx
    Message number DBMAN 305
    You have already implemented Note 1065380.
    Other terms
    CX_SQL_EXCEPTION, message number, RS_EXCEPTION 000, DBMAN 257,  RSBK 242,
    RS_EXCEPTION 000
    Reason and Prerequisites
    The MaxDB internal limit of 4016 bytes or 128 fields for GROUP BY columns was exceeded.
    Solution
    When you implement these corrections, no aggregation is performed for the data (GROUP BY) if the limits of the MaxDB database have been exceeded.
    The limit values for the aggregation bahavior can also be manually reduced if there are problems with the default values.
    Two RSADMIN parameters are provided for this.
    MAXDB_MAX_GROUP_BY_FLDS is the maximum number of GROUP BY fields. The default value is 128.
    MAXDB_MAX_GROUP_BY_LEN is the maximum total length of the GROUP BY fields. The default value is 4000.
    SAP NetWeaver BI 7.00
               Import Support Package 21 for SAP NetWeaver BI 7. 00 (SAPKW70021) into your BI system. The Support Package is available when Note 1270629"SAPBINews NW 7.00 BI Support Package 21", which describes this Support Package in more detail, is released for customers.

  • Error Message while executing the Application

    Hi,
    I am new to Webdynpro and I created my first application by following some blog on a portal.I was able to activate my application successfully and when I executed I get this below error message.
    I checked the cardinality and it is 0..1.My Inti.Lead Selection is set to NO.
    I mappedthe nodes in my views also. But still i don't know whay am getting this error.
    Note
    The following error text was processed in the system RS2 : Adapter error in &VIEW_ELEMENT_TYPE& "VBELN" of view "Z_MYFIRST_WEBDYNPRO.MAIN": Context binding of property VALUE cannot be resolved: Node MAIN.1.NODE_VBAK does not contain any elements
    The error occurred on the application server ucerp18_RS2_00 and in the work process 11 .
    The termination type was: RABAX_STATE
    The ABAP call stack was:
    Method: RAISE_FOR of program CX_WDR_ADAPTER_EXCEPTION======CP
    Method: RAISE_BINDING_EXCEPTION of program CL_WDR_VIEW_ELEMENT_ADAPTER===CP
    Method: GET_BOUND_ELEMENT of program CL_WDR_VIEW_ELEMENT_ADAPTER===CP
    Thanks
    Kiran

    Hi,
    I changed the cardinality to 1:1 and I can see the selection screen. But, can you please explain why I should change this from 0:1 to 1:1.
    Now I have a new error:
    After I enter the sales order Number and hit my FIND button, am getting this error:
    The following error text was processed in the system RS2 : Could not find attribute VBELN
    Thanks,
    Kiran
    Now am getting a different error:
    Invalid operand type for the MOVE-CORRESPONDING statement
    Thanks
    Kiran
    Edited by: kiran dasari on Aug 20, 2009 10:54 PM

  • Error message while uploading the flat file

    Hi Experts,
    I am getting the error message while uploading the flat file.
    Message class: MG
    Number: 147
    The message is: Several descriptions exist for the language JA.
    Please guide me why this error is occuring.
    Regards
    Akshay

    hi,
    how are you uploading the file and where ?
    u can use open dataset  , read dataset or gui_upload
    check this link
    http://help.sap.com/saphelp_nw04/helpdata/en/c8/e92637c2cbf357e10000009b38f936/frameset.htm

  • Error encountered while executing the transform project name.map name. Error:Unable to create the transform. Microsoft.XLANGs.Engine

    Hi All,
    I developed a Biztalk Application aims to upload a flat file data to our system MS SQL Server database. It works fine until one day, an exception is generated as below.
    "Error encountered while executing the transform project name.map name. Error:Unable to create the transform. Microsoft.XLANGs.Engine"
    It continues to generate an exception until I restart the Biztalk instance. And it happens occasionally, no pattern, cannot be traced and debugged.
    Anybody has an idea about this error? Please help, thank you very much.
    The Biztalk Server is running on Hyper-V Virtual machine, Biztalk Server 2009 on Windows Server 2008.
    The Biztalk Application consists of Mapping Functoid, Orchestration, Flatfile Schema, Flatfile Disassembler Pipeline, SQL Send Port, File Receive Port and Send Port
    Eric

    HI Eric,
    I think it might happen because of large message (Out of Memory exception). As you said you have flat file as inbound, you are doing mapping and then sending it to MSSQL
    SO you can check below mentioned things
    1) Any custom pipeline component is used in receive pipeline. (if so optimize the code)
    2) This issue haapen only with large message (BizTalk convert flat file to XMl to if you have 1MB file corresponding XML will be of higher size)
    again all thing mentioned above is assumption.
    YOu can use debugdiag tool to see if memory leak is happening
    http://www.microsoft.com/en-in/download/details.aspx?id=26798

  • An unknown error occurred while executing the PowerShell script:

    Hello all,
    Not the most descriptive title, granted. I'm hoping this may prompt the next version toprovide additional valuable content.
    Kindly requesting any help on this problem. I'm running VMM 2012 R2 version 3.2.7668
    When I try to look at properties of an existing Private Cloud, I get this error, only if I "look" at certain attributes. If I stay away from the specific attributes, everything is hunky dory. For reasons unknown, after I get this error, I have
    to exit and go back into VMM in order to get anything else to run.
    The text in the error dialogue box is not entirely applicable because I was connected to the VMM server and will connect again, when I exit/relaunch.
    An unknown error occurred while executing the PowerShell script:
    The connection to the VMM management server scvmm2.mmmmmm.com was lost.
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Try the operation again. If the issue persists, contact Microsoft Help and Support.
    ID: 27235
    This is what I get in Events
    Warning 4/9/2015 3:27:04 PM PowerShell (Microsoft-Windows-PowerShell) 4100 Executing Pipeline
    Log Name:      Microsoft-Windows-PowerShell/Operational
    Source:        Microsoft-Windows-PowerShell
    Date:          4/9/2015 3:27:04 PM
    Event ID:      4100
    Task Category: Executing Pipeline
    Level:         Warning
    Keywords:      None
    User:          mmmmmm\paufra
    Computer:      tools-francis.mmmmmm.com
    Description:
    Error Message = The connection to the VMM management server scvmm2.mmmmmm.com was lost. (Error ID: 1610)
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Fully Qualified Error ID = 1610,Microsoft.SystemCenter.VirtualMachineManager.Cmdlets.GetSCReplicationGroupCmdlet
    Recommended Action = Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager
    service is started on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Context:
            Severity = Warning
            Host Name = Default Host
            Host Version = 4.0
            Host ID = 94963cd4-5979-4786-9da2-c8814de8c7c3
            Host Application = C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine Manager\Bin\VmmAdminUI.exe
            Engine Version = 4.0
            Runspace ID = 359d7a46-3752-4929-8c09-0de4152d10e4
            Pipeline ID = 16
            Command Name = Get-SCReplicationGroup
            Command Type = Cmdlet
            Script Name =
            Command Path =
            Sequence Number = 91
            User = mmmmmm\paufra
            Shell ID = Microsoft.PowerShell
    User Data:
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-Windows-PowerShell" Guid="{A0C1853B-5C40-4B15-8766-3CF1C58F985A}" />
        <EventID>4100</EventID>
        <Version>1</Version>
        <Level>3</Level>
        <Task>106</Task>
        <Opcode>19</Opcode>
        <Keywords>0x0</Keywords>
        <TimeCreated SystemTime="2015-04-09T22:27:04.993655700Z" />
        <EventRecordID>285</EventRecordID>
        <Correlation ActivityID="{48059811-1A63-41E1-9057-7498D0E4FC20}" />
        <Execution ProcessID="2344" ThreadID="4076" />
        <Channel>Microsoft-Windows-PowerShell/Operational</Channel>
        <Computer>tools-francis.mmmmmm.com</Computer>
        <Security UserID="S-1-5-21-4008432563-1984933819-4238309236-2721" />
      </System>
      <EventData>
        <Data Name="ContextInfo">        Severity = Warning
            Host Name = Default Host
            Host Version = 4.0
            Host ID = 94963cd4-5979-4786-9da2-c8814de8c7c3
            Host Application = C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine Manager\Bin\VmmAdminUI.exe
            Engine Version = 4.0
            Runspace ID = 359d7a46-3752-4929-8c09-0de4152d10e4
            Pipeline ID = 16
            Command Name = Get-SCReplicationGroup
            Command Type = Cmdlet
            Script Name =
            Command Path =
            Sequence Number = 91
            User = mmmmmm\paufra
            Shell ID = Microsoft.PowerShell
    </Data>
        <Data Name="UserData">
        </Data>
        <Data Name="Payload">Error Message = The connection to the VMM management server scvmm2.mmmmmm.com was lost. (Error ID: 1610)
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Fully Qualified Error ID = 1610,Microsoft.SystemCenter.VirtualMachineManager.Cmdlets.GetSCReplicationGroupCmdlet
    Recommended Action = Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager
    service is started on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    </Data>
      </EventData>
    </Event>

    Hi Sir,
    First , please try to run the VMM configuration analyzer on that computer :
    http://www.microsoft.com/en-us/download/details.aspx?id=41555
    In addition , please try to use "VMMTrace" mentioned in following article to collect trace log and find some useful information :
    http://blogs.technet.com/b/jonjor/archive/2011/01/07/vmmtrace-simplified-scvmm-tracing.aspx
    Best Regards,
    Elton Ji
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • I upgraded iTunes to 11.  I now receive an error message which reads - 'The iTunes Library file cannot be saved. An unknown error occurred (-50).  How do I correct this error?

    I upgraded iTunes to 11.  I now receive an error message which reads - 'The iTunes Library file cannot be saved. An unknown error occurred (-50).  How do I correct this error?
    Thanks
    TDB

    I know this doesn't help you Bud, but I've had this issue for at least the last couple of versions.  If I can ask, what is you enviornment like?  Local PC only, libray saved on another PC/Server? 
    In my case my library is on Windows 2003 server with the share mapped to drive M:  This has worked for many years through both XP and Windows 7 until and update a while ago. 
    Thanks,
    Rob

  • Error encountered while executing the transform

    My message failed at orchestration with the following error. Kindly help in finding the issue.
    xlang/s engine event log entry: Uncaught exception (see the 'inner exception' below) has suspended an instance of service 'Ibox.UNEDIFACT.CODECO.Orchestration.CodecoDownload(df91e55f-c6aa-914d-f042-acdb45bdcaf4)'.
    The service instance will remain suspended until administratively resumed or terminated.
    If resumed the instance will continue from its last persisted state and may re-throw the same unexpected exception.
    InstanceId: cc8fac84-47dc-4d31-be15-80c9f86ffaac
    Shape name: CodecoMapping
    ShapeId: 32b0a92d-82f7-4b3a-8e22-a94b53bf2804
    Exception thrown from: segment 1, progress 22
    Inner exception: Error encountered while executing the transform Ibox.UNEDIFACT.CODECO.Orchestration.CodecoMap. Error:Transformation failed..
    Exception type: XTransformationFailureException
    Source: Microsoft.XLANGs.Engine
    Target Site: Void ApplyInMemoryTransform(System.Type, Microsoft.XLANGs.RuntimeTypes.TransformMetaData, System.Object[], System.IO.Stream[])
    The following is a stack trace that identifies the location where the exception occured
       at Microsoft.XLANGs.Core.Service.ApplyInMemoryTransform(Type mapRef, TransformMetaData trfMetaData, Object[] outParams, Stream[] inStreams)
       at Microsoft.XLANGs.Core.Service.ApplyTransform(Type mapRef, Object[] outParams, Object[] inParams)
       at Ibox.UNEDIFACT.CODECO.Orchestration.CodecoDownload.segment1(StopConditions stopOn)
       at Microsoft.XLANGs.Core.SegmentScheduler.RunASegment(Segment s, StopConditions stopCond, Exception& exp)
    Additional error information:
            Exception has been thrown by the target of an invocation.
    Exception type: TargetInvocationException
    Source: mscorlib
    Target Site: System.Object InvokeMethod(System.Object, System.Object[], System.Signature, Boolean)
    The following is a stack trace that identifies the location where the exception occured
       at System.RuntimeMethodHandle.InvokeMethod(Object target, Object[] arguments, Signature sig, Boolean constructor)
       at System.Reflection.RuntimeMethodInfo.UnsafeInvokeInternal(Object obj, Object[] parameters, Object[] arguments)
       at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture)
       at Microsoft.XLANGs.BaseTypes.CompiledXsltWrapperTransform.Transform(IXPathNavigable input, XsltArgumentList arguments, XmlWriter results, XmlResolver resolver)
       at Microsoft.XLANGs.BaseTypes.CompiledXsltWrapperTransform.Transform(IXPathNavigable input, XsltArgumentList arguments, Stream output, XmlResolver resolver)
       at Microsoft.XLANGs.Core.Service.ApplyInMemoryTransform(Type mapRef, TransformMetaData trfMetaData, Object[] outParams, Stream[] inStreams)
    Additional error information:
            Attribute and namespace nodes cannot be added to the parent element after a text, comment, pi, or sub-element node has already been added.
    Exception type: XslTransformException
    Source: System.Data.SqlXml
    Target Site: Void ThrowInvalidStateError(System.Xml.XPath.XPathNodeType)
    The following is a stack trace that identifies the location where the exception occured
       at System.Xml.Xsl.Runtime.XmlQueryOutput.ThrowInvalidStateError(XPathNodeType constructorType)
       at System.Xml.Xsl.Runtime.XmlQueryOutput.ConstructInEnumAttrs(XPathNodeType rootType)
       at System.Xml.Xsl.Runtime.XmlQueryOutput.WriteStartAttribute(String prefix, String localName, String ns)
       at <xsl:template name="compiler:generated"> (36)(XmlQueryRuntime {urn:schemas-microsoft-com:xslt-debug}runtime, XPathNavigator {urn:schemas-microsoft-com:xslt-debug}current, Double {http://schemas.microsoft.com/BizTalk/2003/var}var:v237,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v239, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v240, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v242, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v244,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v246, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v248, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v250, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v252,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v255, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v256, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v258, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v259,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v261, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v262, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v264, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v265,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v267, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v268, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v271, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v272,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v281, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v283, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v284, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v286,
    Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v287, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v289, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v290, Boolean {http://schemas.microsoft.com/BizTalk/2003/var}var:v292,
    String {http://schemas.microsoft.com/BizTalk/2003/var}var:v295)
       at <xsl:template name="compiler:generated"> (12)(XmlQueryRuntime {urn:schemas-microsoft-com:xslt-debug}runtime, XPathNavigator {urn:schemas-microsoft-com:xslt-debug}current)
       at <xsl:template match="/s2:Root">(XmlQueryRuntime {urn:schemas-microsoft-com:xslt-debug}runtime, XPathNavigator {urn:schemas-microsoft-com:xslt-debug}current)
       at <xsl:template match="/">(XmlQueryRuntime {urn:schemas-microsoft-com:xslt-debug}runtime, XPathNavigator {urn:schemas-microsoft-com:xslt-debug}current)
       at Root(XmlQueryRuntime {urn:schemas-microsoft-com:xslt-debug}runtime)
       at Execute(XmlQueryRuntime {urn:schemas-microsoft-com:xslt-debug}runtime)
       at System.Xml.Xsl.XmlILCommand.Execute(Object defaultDocument, XmlResolver dataSources, XsltArgumentList argumentList, XmlSequenceWriter results)
       at System.Xml.Xsl.XmlILCommand.Execute(Object defaultDocument, XmlResolver dataSources, XsltArgumentList argumentList, XmlWriter writer)
       at System.Xml.Xsl.XslCompiledTransform.Transform(IXPathNavigable input, XsltArgumentList arguments, XmlWriter results, XmlResolver documentResolver)

    Hi,
    It is clearly an issue in your map. You can test your map out of Orchestration to make sure it is working.
    "Exception has been thrown by the target of an invocation" is a very generic exception. you
    need the inner exception to see the actual error. You can also try to test the map in the MapTester tool. It also shows also the inner exception. It's designed for BizTalk 2010 but with the .exe file you maybe also can test BizTalk 2006 maps,.
    http://code.msdn.microsoft.com/Execute-a-BizTalk-map-from-26166441
    If this answers your question please mark as answer. If this post is helpful, please vote as helpful by clicking the upward arrow mark next to my reply.

  • Error message while running the payroll-no entry found in table t54c1

    Hi All,
    Im getting this error-error message while running the payroll-no entry found in table t54c1.What is the reason for this error?
    How doi solve it?

    Hello
    From the description of your problem above, your cumulation calender has not been generated for that month.
    Please take necessary action to ensure that calendar type is assigned to pay period in payroll area, by maintaining the payroll period which is represented by Date modifier and period modifier in view maintainance for table T54C1.
    Entries for this table are generated with the program RPUCTP10. (You should not have to create manual entries in this table.)
    Thanks and Kind Regards
    Ramana

  • I am getting the following error message while opening the fire fox browser "sript file:///programe % 20 files/siber%AT% 20roboform/rirefox/components/ref helper.JS:510 in English

    i am getting the following error message while opening the fire fox browser "sript file:///programe % 20 files/siber%AT% 20roboform/Firefox/components/ref helper.JS:510 in English

    ls -l /var/run/lighttpd/
    And how are you spawning the php instances? I don't see that in the daemons array anywhere.
    EDIT: It looks like the info in that page is no longer using pre-spawned instances, but lighttpd adaptive-spawn. The documentation has been made inconsistent it looks like.
    You will note that with pre-spawned information, the config looks different[1].
    You need to do one or the other, not both (eg. choose adaptive-spawn, or pre-spawn..not both).
    [1]: http://wiki.archlinux.org/index.php?tit … oldid=8051 "change"

  • I have an iPhone 4. I tried updating it tonight to iOS7 through my just updated iTunes. I received an error message telling me the update couldn't be completed. My phone then went to the screen asking me to connect to iTunes which can't see my phone. Help

    I have an iPhone 4. I tried updating it tonight to iOS7 through my just updated iTunes. I received an error message telling me the update couldn't be completed. My phone then went to the screen asking me to connect to iTunes which can't see my phone. Help!!

    micron12
    Hi I had a simular problem with my iPhone 4 and iPad 3 and found that the USB connection on the computer was at fault so I moved the connection to a USB port on the Mother board.This curred my problem,see if ti works for you.
    Windows 7 and windows XP

  • I unplugged a USB data device without ejecting it properly via 'Finder'.  Now whenever I plug in the device I received an error message stating that the 'disk was not ejected properly

    Now when I plug in the device I receive an error message stating that the disk was not ejected properly & that next time I connect the 'disk', MAC OS X will attempt to repair any damage to the information on the disk.
    It has not repaired.
    The data I am trying to import is photos & even when I change to a different SD card I receive the same message.
    I am a recent convert from Windows and am new to the MAC way of things.  

    You can repair the SD card using Disk Utility.
    I suggest you copy the photos from your SD card, if you haven't done so already, before using Disk Utility to repair your SD card.

  • HT203175 When I install itunes I received an error message like this:The exception unknown software exception (0Xc06007e) ocurred in the application at location 0x7c812afb

    When I install itunes I received an error message like this:The exception unknown software exception (0Xc06007e) ocurred in the application at location 0x7c812afb. After the installation the computer is showing the message every time.

    If you update your QuickTime Player, does that clear up the iTunes message?

  • I get an error message while converting the file. you do not have the privilege to make changes. I get this message when I try to import a music CD

    I get an error message while converting the file. you do not have the privilege to make changes. I get this message when I try to import a music CD

    Hey amba1015,
    I found an article that talks about similar error messages in relation to importing an audio CD. Check out the recommended troubleshooting steps in here to see if they help:
    Trouble adding music to iTunes library or importing audio CD
    http://support.apple.com/kb/TS1387
    Welcome to Apple Support Communities!
    Have a good one,
    Delgadoh

Maybe you are looking for

  • String and arraylist

    i have this code that retrieves files from a folder and displays them as an array. what i want to do is drop the .xxx extension from the files. i use this code and it works fine                String junk = "1220145678999345.abc";                Syst

  • Safari keeps quiting unexpectedly? can any one help?

    safari worksfor a maximum of 30-60 mins then quits. have tried restarting computer. restating safari. nothing is working can anyone help its starting to get on y nerves now! x

  • Debit billings--select statement

    Hi, I am preparing one alv report related to FI module.There is one colomn called Debit billings. The explanation given for that colomn " Document types RV and DR which debit accounts 110000 , 110500 , 110900 and credit accounts 400000 to 401000 . Ca

  • Changing iOS device volume via adobe native extension

    hello I have created an ANE to control the ios device volume. When I exclude the following code, my ANE functions well, but when I include the code the and reproduce the ANE, I cannot compile the IPA. UIWindow *win = [UIApplication sharedApplication]

  • My id has been log in by someone even i have changed my password

    i have been received apple notification where i have log in itune which i never did, i have changed my passwords twice but still received it. how?