Reconciliation on OVD (configured to point to OID)
Hi,
I have a requirement where I need to reconcile on OVD which will provide a modified view of OID.
Since there is no connector available for OVD, I have configured IPLANET connector for OVD.
Using this connector though I am able to PROVISION Users into OID with OVD in between, it is failing to reconcile users on OID
When I run reconciliation, I get the following error:
*INFO QuartzWorkerThread-1 XL_INTG.SJSDS - Problem searching directory: javax.naming.OperationNotSupportedException: [LDAP: error code 53 - LDAP Error 53: [LDAP: error code 12 - Unavailable Critical Extension]]; remaining name 'cn=Users,dc=ad,dc=mycompany,dc=com'*
There are some links on OVD reconciliation, but of no help for my case -
Re: Recon using sun connector and openldap
Reg: Recon using sun connector
Any suggestions/solution for the above error would be highly appreciable.
Regards
Sundar
Hi there,
See Recon using sun connector and openldap
Thanks,
Andy
Similar Messages
-
Problem with configuration supporting point in MD62
Hi,
well I have detected a problem with my planned independent requirements for some materials.
The materials that are concerned are semifinished product which have an active BOM.
Example :
material A composed with material B and C.
On the material A I have the strategy group 54. For these materials I have "VSE" PIR.
The problem is that for many materials, the VSE needs can not be seen by components.
Example, on material A, I have a VSE need on 15.02.2010, MRP generates a planned order on 15.02.2010 on material A. No problem but I have in MD04 an alert 52 for these PO.
I go to material B or C in MD04 and I don't see any needs ! The planned order needs have not been splitted to the components.
I have seen that if I go to MD62 for material A and if I click on "Configuration supporting point", everything is OK after next MRP Run but the problem seems to go back after few days.
The strange thing is that it works perfectly for some materials and it doesn't work for others materials although there is no differences between data of these materials !
Finally, I have to say that program RM60RR20 is turning every night and I have seen that there are some calls to function DELETE_SUPPOINT. Maybe this program is deleting the supporting point but it should recreate the supporting point after...
Is there anybody which know how this program is working or why sometimes my supporting point is deleted without being recreate ?
Thanks.Hi Frederico,
Have you tried typing the query in query manager and are you sure you've selected the correct column? You can check the column name if you switch system information on and verifying the values in the database for that column.
Hope it helps,
Adele -
Pass Parameter To Configuration Entry Point
In TestStand 2010 I have added a configuration entry point to select a configuration file. (Configure\Select Config File). I'm displaying a LabVIEW GUI which basically prompts the user to select a file. The file path needs to be stored in "FilePath" variable in TestStand.
Problem statement:
1. I'm trying to modularize this configuration entry point. Hence, I would write to "Parameters.FilePath" variable of configuration entry point stored in process model. This variable would be of "pass by reference" type and should eventually update the caller sequence.
However, I don't know how to pass the value from "Parameters.FilePath" to the caller sequence. I'm currently updating the station global variable directly which I think is not the correct method if I think of modularity.
2. I want the configuration entry point that was created ("Select Config File") to be enabled only when testing has not started (I'm just using single pass for my project).
Which variable in TestStand would tell me if the execution entry point "Single Pass" is called or not?hi bce,
[ If I used a station global, how would my changes be saved? Can you do this programmatically? Is there a better way? ]
When Teststand closes, it automatically saves the StationGlobals. You would use PropertyObjectFile.SaveFileIfModified if you needed to force the save. But you shouldn't really need to do this as the latest value is available to all sequences and sequence files.
Regards
Ray Farmer
Regards
Ray Farmer -
How to copy OVD configuration from one machine to another?
We have two machines with OVD servers on them. The configurations should be identical from one machine to the other. We suspect there is a problem with the configuration on one of them. We need to know how to copy OVD configuration from one machine to another.
Can you tell us how to do that?well i have this in mind which may help you.
You would need to have a public ip address to the machine you have consoled to and on internet.
Download the tftp software from below link.
http://tftpd32.jounin.net/
This software does not only act as the tftp server but also you can select the interface of you ethernet card as tftp server ip address.
For ex if you are connected to a console and have a wireless card which is connected to internet also you connect you eth lan card to the eth or fast eth of the router.
you can select which ever interface you want to act as the tftp server.
you will need to add ip addres for you lan card and also config the router port as same if needed. -
Kind of expression for enabling configuration entry point
I need to enable a configuration entry point not only with the "classic" 'CurrentUserHasPrivilege()' (of Engine obj) expression but also if a certain callback is present in the model client file.
I try to use RunState, ThisContext and Execution objects but without results.
Any suggestion?
Many thanks
Luigi Magni (System Engineer - CTA)Hi LuigiM,
I set the enabled expression to the following:
PropertyExists("RunState.InitialSelection.SelectedFile.Data.Seq[\"MySequence\"]")
To one of the Configure Entry Point callback sequence in the process model e.g. the Configure Report Option.
As you can see, the Report option will only be enabled if there is a sequence call 'MySequence' in the the active sequencefile.
This seems to work quite well.
The RunState.ProcessModelClient only appears to be available once the SequenceFile is executing.
Hope this helps
Regards
Ray Farmer
Regards
Ray Farmer -
Sub-menus Configuration Entry Point
From the configure Menu in Teststand, I want to generate a pop-up or a sub-menu whereby a user can input a time that would be read in by Teststand
sequence. Is this possible? By default, I want the time to be set to 8:00AM, in case of the user not making any selection. How can I go about doing this? I was told that this may be possible via Configuration Entry points in the Sequential Model. Can some experienced forum members shed some light on this matter?Would they need to set it during every execution? if so then it makes sense to override the Process Setup Callback.
Otherwise, it sounds like you would need to store this to disk somehow. I wrote an example:
http://forums.ni.com/t5/NI-TestStand/Saving-User-Config-file/m-p/1723094#M34630
I hope you find it helpful.
Regards,
jigg
CTA, CLA
teststandhelp.com
~Will work for kudos and/or BBQ~ -
Calling a Configuration Entry Point from a C# code module
Hi,
Is it possible to call a configuration entry point from a C# code module?
I have a custom process model which creates some configuration entry points.
One of the entry points, calls a C# method in a code module to display a Startup screen for the operator.
In an Editor User Interface, I have added a toolbar, now I want to execute the previous entry point initiated from my C# code to get the Startup screen again when a button is clicked on the toolbar.
Best regardsHi James,
Thanks for your suggestion, but unfortunely the code hangs after executing the entrypoint, if have tried it in two ways, but both have the same result. Do you have any idea how to fix this.
Trial 1:
Engine engine = new Engine(); ApplicationMgr applicationMgr = (ApplicationMgr)engine.GetInternalOption(InternalOptions.InternalOption_ApplicationManager);EntryPoints entryPoints = applicationMgr.ConfigurationEntryPoints; int intIndex = 0;foreach (EntryPoint entryPoint in entryPoints) { switch (entryPoint.Name.ToUpper()) { case "TOGGLE ONLINE <-> OFFLINE": object objEditArgs = System.Type.Missing; entryPoint.Run(objEditArgs); // Application hangs after executing this command, the entrypoint does not execute! break; default: break; }
intIndex++;
Trial 2:
Engine engine = new Engine(); ApplicationMgr applicationMgr = (ApplicationMgr)engine.GetInternalOption(InternalOptions.InternalOption_ApplicationManager);EntryPoints entryPoints = applicationMgr.ConfigurationEntryPoints; int intIndex = 0;foreach (EntryPoint entryPoint in entryPoints) { switch (entryPoint.Name.ToUpper()) {
case "TOGGLE ONLINE <-> OFFLINE": // Application hangs after executing next command, the entrypoint does not execute! applicationMgr.GetCommand(CommandKinds.CommandKind_ConfigurationEntryPoints_Set, intIndex).Execute(true); break; default: break; }
intIndex++;
Best regards -
How to enable keyboard shortcuts for configuration entry point?
Hello All,
In my process model, I have a configuration entry point sequence (sequence). I can able to select the corresponding entry from the menu bar ie. configure --> options (for eg). Now I need to have a keyboard shortcut for the same. In my case if I press (for eg) ctrl+w, the configuration entry point sequence must be called.
Note - I have to do this using .NET programmatically.
Is there any way I can incorporate this mechanism...?
Thanks
ArunHello Arun,
At this time there is not anyway to customize the keyboard shortcut keys for menu items you add to the TestStand sequence editor. R&D is looking into implementing this in a future version of TestStand. I'll pass along your feedback to them, and let them know there are others interrested in this feature.
Kristen
National Instruments -
Pass data from configuration entry point
I have a need to post data from a Configuration Entry Point during a Test UUTs execution. I would like to update a parameter in my test sequence, using the configuration entrypoint if the test sequence is actively running in Test UUts. If it's not active, I would update a .ini file which gets read by the process model when a new Test UUTs entrypoint is started.
My first guess has been to determine if the TestUUTs sequence is active, and I have tried using the PropertyObject RunState.ProcessModelClient.IsExecuting, but I just realized the Configuration Entry Point is always running in the process model.
Everything I have read indicates that most Configuration Entry Points just write data to a file. Am I doing something fundamentally wrong?
How do i determine if my sequence file is being executed with TestUUts?
Thanks for your help. Woefully confused,
Brianhi bce,
[ If I used a station global, how would my changes be saved? Can you do this programmatically? Is there a better way? ]
When Teststand closes, it automatically saves the StationGlobals. You would use PropertyObjectFile.SaveFileIfModified if you needed to force the save. But you shouldn't really need to do this as the latest value is available to all sequences and sequence files.
Regards
Ray Farmer
Regards
Ray Farmer -
Configuring shipping point as Trigger point for posting outbound idoc
Hello All,
I have a requirement that on saving an Outbound Delivery(VL02N), an Outbound Idoc should be posted...but the condtion for posting the idoc should be its shipping point. I am not sure how to configure shipping point as the trigger point for the idoc.
Please suggest.
Thanks for your co-operation.
Regards
AnandHi Anand,
1. Go to transaction: NACE & select application V2 and click on output types.
2. change display <->Change mode.
3. select LAVA and press F6 (to copy Standard output type LAVA to ZLAV).
4. Give ur Z name for the new custom output type.
5. change access sequence from 0005 to 0012(shipping point).
6. Press ENTER and click copy all.
7. Now goto trasaction VV21, give the created output type name. ENTER
8. Maintain entries, shipping point, customer#, Medium as '6' ...etc
Now try VL01N with the given shipping point and check the output ZLAV has been triggered or not?
Let's see, if we miss any configs still!
Keep this as reference:
http://www.erpgenie.com/sapedi/messagecontrol.htm
Reddy -
GetCommand does not return my configuration entry points?
If I'm in a client sequence file and I want to dynamically execute my own configuration entry point in the process model what is the best way to accomplish that?
I am trying to get the application manager through an activex step using Engine.GetInternalOption(InternalOption_ApplicationmManager) and then I choose the GetCommand method with CommandKind_ConfigurationEntryPoints_Set. It will only use an index for one of the 3 default configuration entry points (Report Options, Model Options or Database Options). It throws an index out of range if I try to get my own. This is from James Grey's post here: http://forums.ni.com/t5/NI-TestStand/Calling-a-Configuration-Entry-Point-from-a-C-code-module/td-p/1... (I'm not in .NET though. I just want to use activex steps in TS). The 3 default ones work perfectly. It's only when I try my own that I've added.
Any thoughts?
jigg
CTA, CLA
teststandhelp.com
~Will work for kudos and/or BBQ~
Solved!
Go to Solution.I can call it directly as well but it doesn't exhibit the behavior I want.
Basically we have a process model with a Configuration Entry point called About Test. This calls a sub sequence which has 2 steps in it. The first step is a callback and the second is a VI call. The VI displays a splash screen with our company logo, disclosure and the text (usually a software part number) returned by the callback.
What I want to do is put the SequenceFileLoad callback in our clients and have a step in there that will invoke the About Test entry point upon sequence load.
The series would look like this:
SequenceFileLoad(client)>>About Test Configuration Entry Point(model)>>SubSequence(model)>>About Test Model Callback (client)>>VI Splash Screen(model)
All of this would be a lot easier with a (ProcessModelFileLoad): http://forums.ni.com/t5/NI-TestStand-Idea-Exchange/ProcessModelFileLoad-Engine-Callback/idi-p/225016...
So back to my point about it not working correctly. It doesn't seem to be invoking the model callback when I use New Execution or call the sequence directly.
Also, what is the explanation for my config entry points not showing up at all in the list? it seems that function should grab all config entry points in the model.....
Thanks a bunch,
jigg
CTA, CLA
teststandhelp.com
~Will work for kudos and/or BBQ~ -
Doubt in configuring entry points for iviews
Hi, I have followed the steps of the help about configuring entry points for iviews:
1.-> in the pcd I have created a folder to store iviews for WPC.
2.->I have gived read permission.
3.->I have desactivated the hide root folder check por pcd repository.
4.->I have created a folder in km.
I am loosing in the step "Create a entry point for the folder that you created in step x".
How link the pcd folder that store the iviews with the km folder?
when I try to create a entry point I only can see km folders, How can I choose my pcd folder?
Thanks.
Regards.Try this:
Procedure
1. Choose System Administration → System Configuration → Knowledge Management → Content Management → User Interface → Mapping → Component.
2. Edit the wpcDragExplorerEntryPoints configuration object.
Use the following parameters:
<u>Parameter: Description</u>
displaymode:Specify <i>select</i>
maxproviderprio: Highest priority number that standard entry points can have and still be displayed in the Web content browser
entriesperrow: Number of entry points displayed in each row (default: 5)
entrypointsprefix: Prefix of the entry point repository: If you specify a value for this parameter, standard KM entry points are also displayed in the Web content browser.
Default: /entrypoints
sharedcontent: Semicolon-separated list of paths to be displayed as global entry points for shared content
Examples of parameter values (for sharedcontent param):
displaymode=select,maxproviderprio=30,entriesperrow=5,entrypointsprefix=/entrypoints,sharedcontent=/wpccontent/Cross-Site Content;<b>/pcd</b> -
Hi Experts,
Can i know how to configure End point alais in CE. I need to work on external service callable object in which i need to provide the End point. I was not able to find the same in Administration like GP CAF environment.
Thanks
Gopal.Hi, You can create end points in the NWA.
SOA Management->Technical Configuration->Destination template management. -
Dear All,
I am not expert in wireless and cisco. I need to configure accesspoint 1140 in my network. I have 10 vlans in my network (Switch 2960)
how i can configure accesspoint to used two ssid, one for lan and one for guest this two ssid in separate vlans. I was try like this...
i create vlans on 3750 switch. I connected my accesspoint to switch 2960 (2960 switch is enduser switch). I trunk the port on 2960 switch is connected to access point. I assign ip address to BVI Interface in accesspoint static. i am unable to ping from access point to other vlans, from other vlans to access point.
can any one help to configure access point.
regards.,Basic Wireless LAN Connection Configuration Example
http://www.cisco.com/en/US/customer/tech/tk722/tk809/technologies_configuration_example09186a008055c39a.shtml -
Configuring change pointer in SAP DEPOSIT MANAGEMENT system
Hi,
I am working on SAP Deposit Management system, which is very much similar to a normal R/3 system.
I need to create a change pointer everytime a business partner is created or changed. Can you please guide me through the steps especially
1. what would be the message type i need to configure and activate in BD50
2. What is the object name and Table name that i should select in BD52
And also if there is anything else I need to be doing?
Cheers,
Babs. <b></b><b></b><u></u>Hi Babs
Here are my suggesstions.
1. There are different message types available for business partner, seems it depends on what data you want make synchronous. Try with BUS1006, search for BUPA* for message types.
2. Here you can try for the above message type with object type BUPA_BUP and table as BUT000
Cheers
Manohar
Maybe you are looking for
-
Not Printing the Content of Object:SOme Garbage Value on Screen
i have made one program of Vehicle class which adds and prints the Details of Vehicles in the ArrayList but it always showa the Garbage Value in return. import java.util.*; import java.awt.*; import java.lang.*; import java.io.*; public class Vehicle
-
My iphone4 has the correct Apple ID in the information settings section and asks me to login to my ID most of the time but when I try to update my apps, it asks me to login with an ID that isn't mine. I deleted the wrong ID from my itunes but it sti
-
Master/Detail form with modal edit
I have a master/detail form that I generated using the wizard that I want to change to have a modal Edit button; i.e. the behavior I want is that the form view is initially read-only and you then have to click an Edit button to make the form editable
-
Need help please! - CMP mapping
Hi, After having developped my J2EE program (with SJSE8), I would like to put it on production. For CMP persistence, I did deploy my program one time. Then I used SJSE8 to capture the DB Schema generated and I used it in "sun-cmp-mappings.xml" and I
-
Error: can not attach to oracle 8i
hi, i got an error message 'oracle 12631' saying 'can not attach to oracle 8i,' and 'username retrieval failed' after i tried to config Net8 and log into TOAD(a application program). i used 8i personal ed. Thanks for help. Yun