"RFC system error for destination GTADIR_SERVER",why?

RFC system error for destination GTADIR_SERVER
Hi AlL,
We are working in CRM 6.0.
While creating the Components and Views,i am encounter this Error.
<<
"RFC system error for destination GTADIR_SERVER"
Message no. SGSUB104
Diagnosis
Access to destination GTADIR_SERVER is currently not possible.
System Response
There was a problem with the execution of the function through a Remote Function Call (error in commmunication or communication setup).
The entered destination was GTADIR_SERVER.
The RFC error message reads:
RFC destination GTADIR_SERVER does not exist.
Die Aktion wurde deshalb abgebrochen.
Procedure
Wiederholen Sie die Aktion sp鋞er.
Wenn die Destination GTADIR_SERVER 黚er einen l鋘geren Zeitraum hinweg nicht erreichbar ist, dann verst鋘digen Sie die Systemadministration f黵 GTADIR_SERVER.
Procedure for System Administration
Weitere Informationen - siehe Systemprotokoll in Destination GTADIR_SERVER.
>>
Any ideas?
Thanks & Regards
Edited by: Autumn of Desert on Oct 12, 2009 8:33 AM

Cancelled

Similar Messages

  • RFC system error for destination GTADIR_SERVER

    I just installed trial version 7.0 ABAP SP12. I started the learning path displayed in SE80, create a table and some class for working with it.
    When trying to create a data-element I get the error "RFC system error for destination GTADIR_SERVER". Any hints about what this server is and how to set it up?

    This message is not supposed to appear for customers, but it doesn't cause any harm either.  You can click through and ignore it. 
    The message is removed for customers in SP13.  Check OSS Note 1063482.

  • Error message: RFC system error for destination GTADIR_SERVER (SGSUB104)

    Hello people,
    I'm using Sneak Preview SP12 and getting frequently this error, for example when loading some Web Dynpros already in the system, or creating Z tables.
    If anyone knows how to solve or the cause please help.
    Procedure for solution in message's long text is in german so I don't understand it.
    Many thanks

    I just patched my system to SP12 as well and suddenly received the same message. After searching this forum I only found you having the same problem. While I understand German, the message is meaningless (tells you to try later again and if problem persists, then ask your system admin). In order to get around this message (after all this missing RFC connection is not critical since after confirming it you can proceed without any problems), I simply created an RFC connection of the name GTADIR_SERVER pointing to my very own NSP system.
    Call transaction SM59
    Select ABAP connections and hit the create button
    Enter GTADIR_SERVER as the RFC connection
    Put your system name and system number (like your settings in SAP GUI) in Target Host and System Number fields
    On tab Logon&Security provide client/user id/password
    Usually I prefer to understand why I need to do what I do. I do not know why we need (i.e. why SAP) call(s) this destination, but my gut feeling tells me it is uncritical the way  I got around it. If anyone in this forum can shed some more light on the WHY, this would be great ...
    Best, Jurgen

  • RFC system error

    Hello friends,
          During Table and structure creation i am getting error "RFC system error for destination GTADIR_SERVER" while i am creating domain and data element for that perticular table/structure. Please give me some information about GTADIR_SERVER and also provide information to rectify this error.
    Thanx & Regards,
    Rahul Talele

    Hi,
    In this case please contact your basis. Because it's due to wrong patch. Please install recent patch.
    Best regards,
    Wojciech

  • RFC system error in system/destination  00024No connect to database, sessio

    Hi Experts,
    I am getting the below mentioned error while transporting the TO.Although the transport was successful, Please let me know how to solve the probblem.
    RFC system error in system/destination  Message no.XT107
    Diagnosis:
    an error occured during RFC communications.
    Function:TMS_TP_SHOW_BUFFER
    RFC message :00024N0 connect to database, session terminated
    System responce:
    The function terminates.
    Procedure: correct the error on the whole system and execute the command again.
    Many thanks in advance.
    Regards,
    Suneel

    Hi ,
    sm59- find - TMSADM*- got following --
    TMSADMDV2.DOMAIN_DV2            3
    TMSADMPRD.DOMAIN_DV2            3
    TMSADMQA2.DOMAIN_DV2            3
    when i was checked(test - authorazation) for DV2 and QA2 it shows following error
                              Connection test TMSADMDV2.DOMAIN_DV2
    Connection type:    R/3 connection
    Cancel               User TMSADM has no RFC authorization for function group SYST .
                              Connection test TMSADMDV2.DOMAIN_DV2
    Connection type:    R/3 connection
    Cancel               User TMSADM has no RFC authorization for function group SYST .
    But FOR PRD IT SHOWS
                              Connection test TMSADMPRD.DOMAIN_DV2
    Connection type:    R/3 connection
    Cancel               At least three characters must be different in old/new code
    pLEASE HELP ME TO RESOLVE THE ISSUE
    rEGARDS
    mohsin
    +91-9867577675

  • RFC system error in system/destination TMSADM@ PRD.DOMAIN_DV2

    Hello All,
    STMS > tms alert > tms alert viever  >
    RFC system error in system/destination TMSADM@ PRD.DOMAIN_DV2
    Message no. XT 107
    Diagnosis
    An error occurred during RFC communications.
    Target system: PRD.DOMAIN_DV2(000)
    Function: TMS_CI_PING
    RFC message: connection closed
    please help me to resolve issue
    regards
    Mohsin

    Hi ,
    sm59- find - TMSADM*- got following --
    TMSADMDV2.DOMAIN_DV2            3
    TMSADMPRD.DOMAIN_DV2            3
    TMSADMQA2.DOMAIN_DV2            3
    when i was checked(test - authorazation) for DV2 and QA2 it shows following error
                              Connection test TMSADMDV2.DOMAIN_DV2
    Connection type:    R/3 connection
    Cancel               User TMSADM has no RFC authorization for function group SYST .
                              Connection test TMSADMDV2.DOMAIN_DV2
    Connection type:    R/3 connection
    Cancel               User TMSADM has no RFC authorization for function group SYST .
    But FOR PRD IT SHOWS
                              Connection test TMSADMPRD.DOMAIN_DV2
    Connection type:    R/3 connection
    Cancel               At least three characters must be different in old/new code
    pLEASE HELP ME TO RESOLVE THE ISSUE
    rEGARDS
    mohsin
    +91-9867577675

  • RFC system error: Screen output without connection to user

    After running transaction SMWP, we nagivate to the "Parameters for object load management" node using the following path:
    Runtime Information -> Adapter Status Information -> Parameters in R/3 Backend(s) -> ECC -> Parameters for object load management
    Under the node “Parameters for object load management”, when we double click any of the entries we receive the following error message in the form of a pop-up: “RFC system error: Screen output without connection to user”.
    Has anyone encountered the aforementioned error?

    Hi,
    while creating the syncbo you have to give the RFC destination for corresponding Bapi wrappers
    so plz check that.
    and can you please explain the exact error in detail and add the trace..
    Regards
    Manohar

  • When I use my dvd on my Imac I get a system error for the visualisor when switching to apple TV

    When I use my dvd on my IMac I get a visualisor system error when I activate Apple TV

    How would I check to see if the like works when I enable via the inspector pane
    If you enable hyperlinks when you click on the link link to the pdf file it will open a browser window and display the pdf file.
    I upload the pdf files to the server and link to them as if they were an external web page:
    That's been more reliable for me than linking to the file as Link To: A file and have iWeb upload the pdf file to the serve.

  • System error for tax jurisdiction procedure

    Hello:
    While doing billing for foreign customers we got a peculiar error like:
    System error: level of the default TXJCD is not eq.1.
    do any one had info on this.

    Please see the following sap note:
    Note 304215 - Error message FF776 during transfer to accounting
    Note 306506 - Error FF769 during release to accounting
    hope this will help you!

  • RFC system error in system/destination TMSADM@P3Q.DOMAIN_P3D Msg No. XT107

    Dear All,
    Whenever I run Transaction STMS and select the quality system, It is asking password in order to see the requests.
    Whenever I provide the password, then I can see the request numbers but I cannot see the short text maintained for that.
    But I can import the request.
    Please suggest regarding this.
    I will award with good points.

    Hi Ganesh,
                   AS usual if you want to see the request in your quality system, Tms will
                   use TMSSUP@domainname rfc. It will not use TMSADM rfc.
                   Check whether that rfc working  properly or not.
    Regards,
    Vamshi.

  • RFC connection error for PS_ACCESS_1 and PS_ACCESS_2

    dear all,
    i have created the RFC destination PS_ACCESS_1 and PS_ACCESS_2 with TCP/IP. i also installed WDPS* files in *sapgui\ps\access folder. now i m checking for 'TEST CONNECTION' in sm59 for PS_ACCESS_1 and PS_ACCESS_2 but it is giving  'Error when opening an RFC connection' this error. pls suggest the solution for this problem.
    am i missing any other settings? i m using SAP ECC 6.0. is it comfortable with this? is it required any configuration from basis side?
    regards,
    vicky.

    HI,
    please check the RFC Trace File at SM59 -> RFC -> Show trace file.
    For better tracing delete the Trace File first and recheck the RFC Dest.
    Regards,
    Gordon

  • RFC Connection Error (for end-to-end Monitoring)

    Hi,
    I am configure End-to-End monitoring in XI 3.0 SP20, PMI does't show data in end-to-end monitoring... anyway!!! I check RFC connection PMI
    RFC destination name: PMIXQA90020080827
    in TEST connection I am getting an error: "Group PUBLIC not Found" where may I define that PUBLIC to solve this problem please let me know.... thanks
    and what is Group PUBLIC in RFC ??? what does it do???
    Is there any notes I can read for related issue, please help me out this
    Thanks a lot in advanced
    Edited by: issue2008 issue on Aug 28, 2008 10:03 AM

    Thanks for reply... SURE I can tell you
    Connection Type: 3 R/3 connection
    ScreenShot shows blow:
    http://www.flickr.com/photos/25222280@N03/2806290586/sizes/o/
    Thanks
    Edited by: issue2008 issue on Aug 28, 2008 10:20 AM

  • Smartform System Error for VF03 output type

    Hi Friends,
    Error encountered in Smartform:
    Message no. SSFCOMPOSER181
    Diagnosis
    You tried to switch to the next table column, but no other column exists. The current column is 10. The line type %LTYPE1 contains only 10 columns.
    System Response
    The system issues an error message.
    Procedure
    Check whether the current line type is the desired line type and whether you defined a switch to a new table line.
    %LTYPE1  contains only one cell consisting Material Description & Code .Apart from that nothin is there in line.
    Please help.
    Regards,
    Abhishek.

    Hi,
    check what is going else for JEX billingtype documents.
    if that does not work out you can try to locate where it is going wrong.
    how you do that: Disable a part of your form with conditions.
    then if you have done it so far you didn't get that error meesage. Then shrink the part you have disabled until it goed worng again. Then it is going wrong in the last part you have enabled. It is a lot of work but debugging in smartform is not as easy as in sapscript.
    success., Gr., Frank

  • Source System Error for 0Material_Attr

    Hi Gurus,
    I have New BI System, when i m loading 0Material_Attr, the whole data is coming but with the status Red. May b the error is with source system. I checked in PSA maintenance and the error detail in source system is mentioned below.
    "Value 'A3000014500L ' for characteristic 0MATERIAL is in external format"
    "0MATERIAL : Data record 1 ('A3000014500L '): Version 'A3000014500L ' is not valid RSDMD 194".
    for detail error check the link below
    https://docs.google.com/document/d/1v4uHeg6Ci29zv0qJ21dOH7gttuQyg_VZsLM2IMfZEuM/edit?hl=en&authkey=CLnd8P4H
    can anybody help in this regard.
    Thanks in advance.
    Regards
    Manna Das

    Hello Manna Das,
    0Material has conversion Exit MANT1 which converts the Material in the external format to internal format of the system.
    Can you please check if the Converison exit is there?
    Thanks,
    Sarat

  • OWA 2013 watchdog system errors for Lync 2013 -

    OWA Farm is configured on two 2012 servers. Lync 2013 installed on server 2012 as well.
    I can access all services, internally and externally without issues on the client end.
    However, my OWA farm machines are marked as Unhealthy per get-OfficeWebAppMachines.
    The OWA Farm system Logs show multiple events related to source Office Web Apps Monitoring, event ID(s) 1004, 1010, 2004, & 2010.
    What are the BroadcastServicesWatchdog_Wfe & AgentManagerWatchdog that are running, reporting these event codes, and where can it be managed?
    The actual event codes
    1004:
    <?xml version="1.0" encoding="utf-16"?>
    <HealthReport xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
      <HealthMessage>AgentManagerWatchdog reported status for AgentManagerWatchdog in category 'Recent Watchdog Reports'. Reported status: Machine health is Unhealthy</HealthMessage>
    </HealthReport>
    1010:
    <?xml version="1.0" encoding="utf-16"?>
    <HealthReport xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
      <HealthMessage>BroadcastServicesWatchdog_Wfe reported status for BroadcastServices_Host in category '3'. Reported status: Contacting Participant.svc failed with an exception: The remote server returned an error: (404) Not Found.</HealthMessage>
    </HealthReport>
    2004:
    <?xml version="1.0" encoding="utf-16"?>
    <HealthReport xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
      <HealthMessage>AgentManagerWatchdog reported status for AgentManagerWatchdog in category 'Recent Watchdog Reports'. Reported status: Machine health is Unhealthy</HealthMessage>
    </HealthReport>
    2010:
    <?xml version="1.0" encoding="utf-16"?>
    <HealthReport xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
      <HealthMessage>BroadcastServicesWatchdog_Wfe reported status for BroadcastServices_Host in category '3'. Reported status: Contacting Participant.svc failed with an exception: The remote server returned an error: (404) Not Found.</HealthMessage>
    </HealthReport>

    Yes, PPTs can be shared correctly; and the urls have been verified.
    As to setting the http auth settings ~ this Farm isn't integrated with SharePoint, and is only in use for Lync 2013.
    It is clear that these additional service executable , AgentManagerWatchdog, BroadcastServicesWatchdog, and BroadcastServicesWatchdog_Wfe
    are from the OWA services to manage system health.
    Where can they be configured, or worked with?  They reiterate that
     Reported
    status: Contacting Participant.svc failed with an exception
    Which leads to more alerts about the Unhealthy state of the machine. What is the "participant.svc"  ?? that is cannot
    contact? Is this internal to the OWA Farm, or is this a remote service connectivity check the Lync Front End servers?

Maybe you are looking for

  • How to extract data from an encrypted hard drive

    Ok so i have a powerbookG4 with a dead logic board and i'm trying to extract all the data that i have from my hard drive. so i took out the hard rive and put it in a USB 3.5 hard drive enclosure, i can access some of the hard drive but the important

  • Save 3d plot to excel as an image

    I am in the report phase of the project and would like to be able to save a 3D plot image (not the data) to an Excel spreadsheet. Any ideas? (The Print.Vi Invoke Node function methods for the front pane are not available in the RTE.) Solved! Go to So

  • HT1725 I only got part of a song I paid for

    I purchased a song and when I played it back it was incomplete. What can I do about this?

  • Adobe Premier Elements 12 on MAC

    Can I transfer my Adobe Preimer Elements 12 from my Windows PC to a new MAC OX X 10.9.2

  • Error with printing via .sh file

    Hi all, We're currently learning Documaker and we were given an existing workspace to work with. In the workspace, there is a .sh file that when run should generate PDFs from an XML file. Upon runtime, the pdf generated is 0 bytes and thus cannot be