Runtime error for Inspection Point Results Recording

Hi,
I am changing the already done Results Recording for using already used Inspection Point.
I am getting the runtime error. Anybody came across such error?
Regards
Ramakanth

Hi,
In the in-process inspection I am using Inspection Points. Initially I have done Results Recording once with quantities.
And then again I wanted to change the quantities for the same Inspection Point. So, I went to Results Recording for same Inspection Point and changed the quantities and saving. At this event I am getting Runtime error.
I  have even deactivated one BADI INSPECTIONLOT_UPDATE and tried again. Even then I am getting same error.
Ultimately my requirement is this:
My client wants UD at operation level. They want only quantity which is accepted in Results Recording to be moved to the next operation. In the operation level confirmation the system should only accept the quantity which is accepted in Results Recording.
Any suggestion in this regard.
Thanks
Ramakanth

Similar Messages

  • Error while doing calibration (result recording)

    Hi friends,
    while doing inspection lot processing, when i do the result recording it is giving the error : selected set not assigned to inspection points.
    when i checked the setting in spro as:
    QM-- Quality Planning -- Inspection Planning - General - Define Identifier for Inspection Points
    300: Inspectio of Equipments
    Default for valuation inspection point
    Plant : 1000             Selected Set: 18 (created as an selected set )
    now the system is giving the following error:
    Entry 1000 3 18 does not exist in QAPM (Check entry)
    Gurus please suggest me where i am doing wrong. is there any other setting which i need to check.
    waiting for you prompt answer.
    Pankaj

    i solved the problem
    thanx

  • Settings for inspection point user field

    Hai gurus,
    i want to know the settings for inspection point user field(150)
    1) Field combination = 150
    2 )Inspection type = ?
    3) Functional location- field active  = ?(predefined field)
    under user field
    1)Text length 18 - Field active = ?
    2)Text length 10 - Field active = ?
    3)Number  length 10 - Field active = ?
    4)Number length  3 - Field active = ?
    5) Date - Field active = ?
    6) Time - FIeld active = ?
    waiting for positive reply.
    regards,
    sekar chand

    dear Sekar
    1) 150 inspection point is maily used for production related inspection. 03 , 04 . it is a freely defined inspection point which means you want to carry out several inspections for each operation during the production process
    2) It is not Inspection type it is inspection point type- There are mainly 3 inspection point type
    Freely defined - explained
    Equipment related - You need this inspection point type if you want to carry out calibration inspections and record the results of test equipment inspections or inspections of functional locations
    Inspection points to identify samples-You need this inspection point type if you want to manage samples and record inspection results for physical samples
    3) Predefined field is for identification of the inspection point.
    Example for inspection point type  1
    For inspection point type 1 (inspection point for equipment) that is used, for example, in a calibration inspection, the equipment number must be entered. (To access the results recording function, however, you can use a different key word instead of 'equipment number', such as, 'test equipment').
    Example for point 3
    The sample-drawing procedure determines the number of samples to be taken. The system automatically creates an inspection point for each sample.
    4) User fields are again identification. You can add in key work text which will appear while result recording.
    5) Field Active  -This helps in sorting out the user fields.  An identification field is only active if you have made an entry in this field.Fields with numeric entries are required fields. The numbering sequence that you define for these fields uniquely identify an inspection point.
    a typical example can be User field/field active/keyword combination
    1)Text length 18 -1 -Inspector Name
    2)Text length 10 - 2- Location
    3)Number length 10 - 3- Shift No
    4)Number length 3 - 4- Section No
    5) Date - 5- Date
    6) Time - 6-  Time
    please Date and Time populates automaticaly. it is not mandatory that you use all the fields
    Hope this helps
    Regards
    gajesh

  • BAPI for inspection point

    Hi,
    I am trying to find BAPI through which i want to do inspection point and result recording. If anyone has done then let me know which bapi is suitable and provide what are all data's need to pass.
    Regards / US

    Hi,
    Check the documentation for function BAPI_INSPOPER_RECORDRESULTS. That gives a pretty detailed description of all the import requirements
    Functionality
    You can use this method to confirm the result of a quality inspection for an inspection operation or inspection point. The following functions are supported:
    Creating an inspection point 
    Closing an inspection point 
    Changing inspection point data 
    Recording inspection results at characteristic level (summarized) 
    Recording inspection results at sample level (summarized) 
    Recording inspection results at single value level
    You define within an inspection operation whether you work with or without inspection points. In accordance with this specification, the parameter INSPPOINTDATA is required or optional.
    Regards,
    John

  • ABAP runtime error for 0CRM_OPPT_H and I while running RSA3

    hello Gurus,
         I'm having problems while running RSA3 transaction for these data sources.
    0CRM_OPPT_H
    0CRM_OPPT_I
    0CRM_SALES_ACT_1
    0CRM_SALES_ACT_I.
    I'm getting ABAP runtime error for these.
    This is the error:
    Runtime Error          CALL_FUNCTION_CONFLICT_TAB_TYP
    Exception              CX_SY_DYN_CALL_ILLEGAL_TYPE
    I tried finding OSS notes for these, but I didn’t succeed.
    I activated the data source from RSA5, and then I tried RSA3. That time I got “Errors occurred during extraction”.
    After that I activated delta at BWA5, then I started getting runtime error.
    Even though I activated at BWA5, I am not able to see the data sources at BWA7.
    Am I missing any thing…please guide me through this….
    Thanks
    RKR

    Thanks for your replay... All the DS and related tables are active..
    But wen I tried to re-generate the DS again... this is the warning I'm getting... Any idea why I'm getting this....
    The even-numbered length of the DEC field SAMPLE_QTY_ALLOW can lead to problems
    <b>Message no. R8569</b>
    <b>Diagnosis</b>
    You want to use the field SAMPLE_QTY_ALLOW in the extract structure for DataSource 0CRM_OPPT_I. This field has a field of type 'DEC' (or 'CURR' or 'QUAN') with an even number of characters.
    This can create problems since the length resulting from calculations in ABAP (for example, in extractors or Customer Exits for extraction) is too large to be inserted in the database later (PSA in BW), causing a short dump.
    <b>Procedure</b>
    This warning is only relevant when the maximum length of this field is exceeded during extraction, for example when the field is expanded in the Customer Exit through a calculation.
    More information and a remedy can be found in SAP Note 641744.
    When I search the OSS note, SAP suggesting to apply 883310 note.
    In my company we are using CRM 4.0 servie pak8. SAP suggsting to install service pak 11, but my client is not interested to upgrade to 11 as CRM people are working on service pak 8.
    By any chance we can use specific note which change the ABAP code to solve this problem... Please give me some suggetions...
    Thanks
    RKR

  • When will Reader 9's Runtime error for redirected Application Data be fixed??

    Has anyone heard when Adobe will fix Reader 9's Runtime error for redirected Application Data??  It's still happening with 9.1.3 for only users who have their Application Data folder redirected via Group Policy.
    It's been going on for some time, as evidenced by the following link, and my own personal pain fighting this
    http://forums.adobe.com/thread/391738?start=100&tstart=0

    Also posted here: http://forums.adobe.com/thread/391738
    I haven't read through all of the posts, but the general consensus I have is that the issue is in fact related to the redir
    ection of the Application Data folder. The main issue being that the use of a UNC path causes the error described, with some mention to explicit user permissions on the root of the folder path.
    I was just recently made aware of this issue in our environment. Apparently we've held off upgrading to Adobe 9.x because of this issue. After a little research, it was apparent that simply modifying the default Folder Redirection policies is not possible because the use of a mapped drive is not supported.
    I haven't had a chance to test this yet, and may not be able to for some time, so I thought I would share this in case someone else might be able to test. The idea being to simply use a custom ADM file to force the redirection of certain profile folders. Again, I haven't tested this using a mapped drive in the path, but I have successfully used the same settings below to redirect other folders not available by default in Group Policy.
    1) Copy the text between ----- Start of ADM ------ and ----- End of ADM ------ and paste it into a text file.
    2) Rename the .txt to .adm.
    3) Load the ADM template into a GPO.
    4) Right click "USER Custom Settings", select "View", select "Filtering" and uncheck the option "Only show policy settings that can be fully managed".
    5) Configure the "Redirect Application Data" option as enabled, and enter a mapped drive path.
    6) Test.
    I'm interested to hear if this is a viable solution or not.
    ------ Start of ADM -----
    CLASS USER
          CATEGORY "USER Custom Settings"
                CATEGORY "Folder Redirection Settings"
                      POLICY "Redirect My Documents"
                      EXPLAIN "By default files are stored as part of the
    user's profile.\n\nConfigure alternative locations here."
                      KEYNAME
    "Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders"
                      PART "Redirect to" EDITTEXT
                            VALUENAME "Personal"
                            MAXLEN 255
                            DEFAULT ""
                            EXPANDABLETEXT
                      END PART
                      END POLICY ; RedirectHistory
                      POLICY "Redirect Application Data"
                      KEYNAME
    "Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders"
                      EXPLAIN "By default files are stored as part of the
    user's profile.\n\nConfigure alternative locations here."
                      PART "Redirect to" EDITTEXT
                            VALUENAME "AppData"
                            MAXLEN 255
                            DEFAULT ""
                            EXPANDABLETEXT
                      END PART
                      END POLICY ; RedirectHistory
                      POLICY "Redirect Cookies"
                      KEYNAME
    "Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders"
                      EXPLAIN "By default files are stored as part of the
    user's profile.\n\nConfigure alternative locations here."
                      PART "Redirect to" EDITTEXT
                            VALUENAME "Cookies"
                            MAXLEN 255
                            DEFAULT ""
                            EXPANDABLETEXT
                      END PART
                      END POLICY ; RedirectCookies
                      POLICY "Redirect Favorites"
                      KEYNAME
    "Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders"
                      EXPLAIN "By default files are stored as part of the
    user's profile.\n\nConfigure alternative locations here."
                      PART "Redirect to" EDITTEXT
                            VALUENAME "Favorites"
                            MAXLEN 255
                            DEFAULT ""
                            EXPANDABLETEXT
                      END PART
                      END POLICY ; RedirectFavorites
                      POLICY "Redirect History"
                      KEYNAME
    "Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders"
                      EXPLAIN "By default files are stored as part of the
    user's profile.\n\nConfigure alternative locations here."
                      PART "Redirect to" EDITTEXT
                            VALUENAME "History"
                            MAXLEN 255
                            DEFAULT ""
                            EXPANDABLETEXT
                      END PART
                      END POLICY ; RedirectHistory
                      POLICY "Redirect Recent Documents"
                      KEYNAME
    "Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders"
                      EXPLAIN "By default files are stored as part of the
    user's profile.\n\nConfigure alternative locations here."
                      PART "Redirect to" EDITTEXT
                            VALUENAME "Recent"
                            MAXLEN 255
                            DEFAULT ""
                            EXPANDABLETEXT
                      END PART
                      END POLICY ; RedirectRecent
                END CATEGORY
          END CATEGORY
    ------ END of ADM -----

  • Defect recording for inspection points

    Hi,
    My client having requirement of recording the defects every hour.in standard SAP defects recording with respect to inspection point is not possible.Is there any other way to do this.
    Regards,
    S.P.Selvathangam

    Hi,
    It is not a problem follow the below step.
    1). Go QM01 enter notification type Q3 (Manual Defect and Notification creation) and press enter.
    2). After enter system will raise the one pop up screen here enter the production order as well as operation number and press enter.
    3), After that it will open defect with notification screen here you can enter defect qty, defect code reason, causes etc and save.
    For any query revert.
    Thanks & Regards,
    S.Babusingh

  • Error in operation level result recording

    Hi,
    I need held; result recording of inspection type =03 (operation level Quality inspection)
    A product manufacture via three operations (10, 20, 30)
    All operation quality inspection active let operation no-10, all products reject and confirm as rework.
    Next operation level quality record is done but confirmation not allow Reason is operation -10, rework quantity, (Actual quantity is more than planned quantity)
    How to add the quantity after reworks for next operation quality inspection?
    Pl helps me finding the solution.

    Hi,
    As per your more clearence , As per Example  production order Quanity =1, passes 3 operation10,20,30
    Operation=10 require rework as per quality ,
    Operation =20 system raise the error message = Operation =10 rework .
    If want to operation =10 ok Quantity =1 then system raise error messges =Actual quanity more than planned Quanitity
    ( 1 Rework + 1 Ok ) .
    Supose rework order create and confirm then next 20 & 30 operation how complete .
    Real scenerio :- Rework on operation =10 then again Quality check then goes to 20 operation Quality check pass / Rework if rework then again quality pass then goes to next operation level
    I hope under stand my problem
    Need help- please

  • Pop-up screen does not appear for inspection point- In-process inspection

    Hi,
    We havs set up inspection points( time-based) in the master recipe. In that inspection point , we have defined date,time and inspector name as 3 fields to be maintained , before the results recording can start for each characteristic.
    Even though the inepction point is assigned in the header QM data of recipe , system does not give the pop-up at all to record the date , time and inspector's name.
    Please let me know what settings might be missing to get this pop-up screen to record the inspection date,time and inspector's name.
    Regards,
    Manohar

    The Sampling procedure with free inspection points radio button is chosen. However, we are not getting the pop-up screen of QE11.
    What we are trying to get in QA32 , is when we click on "results recording" push button , we want to get QE11 screen to pop-up so that the inspector's name and date and time are recorded , before the results recording screen comes.
    Please suggest whether this is a personal setting or master data setting or config setting or some exit to be used.
    Regards,
    Manohar

  • Reader 9.3 produces Runtime error for all .pdf files on hard drive and email

    Does anyone have a resource that can show me how to eliminate a runtime error with Reader 9.3.1, Windows XP w/ SP3 and IE7. I have recently had all .pdf files located on my hard drive and in emails refuse to open because of this message:
    "Runtime Error!
    Program C:\Program Files\Adobe\Reader 9.0\Reader\AcroRd32.exe
    This application has requested the Runtime to terminate it in an unusual way.  Please contact the application's support team for more information."
    So far, I have uninstalled and reinstalled Reader 9.3 from the website; added update 9.3.1 and tried to reopen files with no success.
    My organization sends a ton of .pdf files and it is not good when you can't open them for review and action.

    Hi All,
    Although I don't normally post in forums, I thought it prudent to lay this matther to rest.  I have tested the following solution:
    It appears that Adobe Reader likes to check access to each parent folder as well as the actual application data folder.  Apparantly there are other programs that also do similar things. As a result if you have your appdata redirected to \\server1\profiles\%username%\appdata adobe reader would first try directly access \\server1\profiles.  If the user does not have to Traverse folder permission, this fails. Typically you will need to change your permissions on you profile share from:
    -                   Users - Read Attributes (Apply to: This folder, subfolders and files)
    -                   Users - Read Extended Attributes (Apply to: This folder, subfolders and files)
    -                  Users - Create Folders/Append Data (Apply to: This folder, subfolders and files)
    -                   Users - Read Permissions (Apply to: This folder, subfolders and files)
    To the share permissions suggested by Microsoft in KB 274443:
    -                   Everyone - Create Folder/Append Data (Apply onto: This Folder Only)
    -                   Everyone - List Folder/Read Data (Apply onto: This Folder Only)
    -                   Everyone - Read Attributes (Apply onto: This Folder Only)
    -                   Everyone - Traverse Folder/Execute File (Apply onto: This Folder Only)
    Hopefully this helps everyone.

  • Runtime errors for Branched in SXMB_MONI

    Hi,
    After PI 7.0 has been upgraded to SPS16, every time I try to display a message in status "Branched" from SXMB_MONI I get a runtime error. Also I got an error when trying to display it from RWB Monitor.
    Messages in other statuses donu2019t have problems
    Any suggestion why is that? Thanks.
    Janos

    Hi,
    It is  error Message_type_X, but I don't think it is a SAPGUI problem, since I got the same problem with SAPGUI 710 and SAPGUI 640
    Bellow is the extract from ST22.
    Runtime Errors         MESSAGE_TYPE_X
    Date and Time          22.09.2008 13:50:43
    Short text
        The current application triggered a termination with a short dump.
    Error analysis
        Short text of error message:
        Control Framework : Error processing control
        Long text of error message:
         Diagnosis
             An error occurred when the system tried to process the commands
             from the Automation Queue on the presentation server.
             There are several possible reasons for this:
             - The installation of the SAP GUI on the presentation server is
             faulty or obsolete.
             - There is an error in the application program
             - There is an error in the SAPGUI or an integrated control
         Procedure
             1. Make sure that you have imported the appropriate Support
             Package, the current kernel, and GUI patch for the release of your
             system
             2. Check whether the error occurs locally on one or a few PCs, or
             generally on all PCs. Note whether the error only occurs for some
             users, for example because of a specific Customizing setting.
             If it only occurs locally, this suggests an installation problem
             with the PC. Check the installation; if necessary, reinstall the
             software. In the dump, search for the SY-MSGLI field, since it may
             point to the cause of the error.
             3. Activate the Automation Trace (in accordance with SAP Note
             158985).
             4.Start the transaction and continue until the screen immediately
             before the dump.
             5. From the System -> Utilities menu, choose Autom. Queue,
             Synchronous Processing.
             The status bar of the GUI displays the text:
                "Automation synchron flush mode on"
             6. If you now proceed with the application, the short dump will
             display the ABAP call that caused the error; the Automation Trace
             will contain the error on the presentation server.
             7. If necessary, load the short dump and trace files on to
             sapservX, so that SAP can analyze them.
        Technical information about the message:
        Message class....... "CNDP"
        Number.............. 006
        Variable 1.......... " "
        Variable 2.......... " "
        Variable 3.......... " "
    How to correct the error
        Probably the only way to eliminate the error is to correct the program.
        If the error occures in a non-modified SAP program, you may be able to
        find an interim solution in an SAP Note.
        If you have access to SAP Notes, carry out a search with the following
        keywords:
        "MESSAGE_TYPE_X" " "
        "SAPLOLEA" or "LOLEAU02"
        "AC_SYSTEM_FLUSH"
        If you cannot solve the problem yourself and want to send an error
        notification to SAP, include the following information:
        1. The description of the current problem (short dump)
           To save the description, choose "System->List->Save->Local File
        (Unconverted)".
        2. Corresponding system log
           Display the system log by calling transaction SM21.
           Restrict the time interval to 10 minutes before and five minutes
        after the short dump. Then choose "System->List->Save->Local File
        (Unconverted)".
        3. If the problem occurs in a problem of your own or a modified SAP
        program: The source code of the program
           In the editor, choose "Utilities->More
        Utilities->Upload/Download->Download".
        4. Details about the conditions under which the error occurred or which
        actions and input led to the error.

  • Runtime error for Audit Log reports

    Hi,
    I have activated Reports feature at Site Collection level and then tried to run custom report for Dashboard library under Audit Log Reports but I got Run Time error. I tried on my local machine and on server.
    Can any body let me know how to resolve this issue to get custom report?
    Any help would be appreciated.
    BELOW IS THE ERROR MESSAHE:
    Server Error in '/' Application
    Runtime Error
    Description: An application error occurred on the server. The current custom error settings for this application prevent the details of the application error from being viewed remotely (for security reasons). It could, however, be viewed
    by browsers running on the local server machine.
    Details: To enable the details of this specific error message to be viewable on remote machines, please create a <customErrors> tag within a "web.config" configuration file located in the root directory of the current web application.
    This <customErrors> tag should then have its "mode" attribute set to "Off".
    <!-- Web.Config Configuration File -->
    <configuration>
    <system.web>
    <customErrors mode="Off"/>
    </system.web>
    </configuration>
    Notes: The current error page you are seeing can be replaced by a custom error page by modifying the "defaultRedirect" attribute of the application's <customErrors> configuration tag to point to a custom error page URL.
    <!-- Web.Config Configuration File -->
    <configuration>
    <system.web>
    <customErrors mode="RemoteOnly" defaultRedirect="mycustompage.htm"/>
    </system.web>
    </configuration>
    AEDLA.

    The audit log reporting is kind of tricky to work with...until you know what you're doing.
    Some things to check: Do you have the Reporting feature enabled?  Do you have auditing enabled on sites in this site collection?  Have any events been triggered that would have written to the audit logs?  Did you specify an output library
    for the report?  Will the report have any data?
    Also, look at the SharePoint logs in C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\14\LOGS\ and let us know any "Unexpected" errors.
    Bob Guidinger
    Please remember to click "Propose As Answer" if a post solves your problem or "Vote As Helpful" if it was useful.

  • Re: Runtime error for updating z table

    Hi all,
    I have a Z table ZABC with 2 following fields
    REC1     type     PERSNO       length    8
    +REC2    type       STRING         length   1000     +
    In my program I declared an internal table like this
    ITAB  TYPE TABLE OF ZABC WITH HEADER LINE.
    At the end of the program, when I have the new info, I passed them into ITAB, and loop at it to update the Z table
    LOOP AT ITAB.
        INSERT ZABC FROM ITAB.
      ENDLOOP.
    Then I got run time error saying
    Runtime Errors         DBIF_RSQL_INVALID_RS
    Exceptn                CX_SY_OPEN_SQL_DB
    An exception occurred. This exception will be dealt with in more detail
    below. The exception, assigned to the class 'CX_SY_OPEN_SQL_DB', was not
    caught, which
    led to a runtime error. The reason for this exception is:
    The maximum length of the long field of the specified table is defined
    in the ABAP Dictionary. The current length of the long field corresponds
    to the value of the preceding field, which consequently
    must be numeric.
    In this case, the value in this field was greater than the maximum value
    defined for the long field in the ABAP Dictionary.
    The term "long field" refers to all fields that are created in the ABAP
    Dictionary with the data type STRING, RAWSTRING, LCHR, or LRAW.
    The problem is at this position
    LOOP AT ITAB.
       INSERT ZABC FROM ITAB.
      ENDLOOP.
    I know something wrong with the string type but I need to update the whole string structure for the whole record type (rather than updating field by field). need help! thanks!

    hi,
    the syntax would be as follows:
    INSERT ZABC FROM TABLE ITAB ACCEPTING DUPLICATE KEYS.
    This will discard the duplicate records & append all the other records from table itab into zabc.
    LOOP ....... ENDLOOP statements are not required.
    Regards,
    Jignesh.

  • Inspection lot result recording

    Hi,
    Some of the characteristic specification are fixed and we want it to appear as it is while result recording. So please confirm how it can be achieve.
    For example : If for product A our specification(inspection plan master) is moisture = < 2. So while result recording this moisture is considered as actual result and is not been changed so we want to fix it instead of typing again and again in result recording.
    Regards

    No, its not possible in standard SAP.  A simple search probably would have shown you that.
    You'd need to use a user exit and add code to pre-populate the values you want valuated.  Please research the user exits before asking the next obvious question.
    Craig

  • Accept tab not activated for characteristics in result recording screen

    Hi,
    'Accept and Reject tab' is active only for few characteristics in result recording screen.After entering all the inspection data's system is manually valuating each MIC.
    Pls. help me on how to activate the 'Accept and Reject tab'  in results recording.
    Regards,
    Shrini

    Dear Gajesh,
    Thanks for your prompt reply.
    I have created a SAMPLING PROCEDURE --> QUAL-DMS.
    IN ASSIGNMENTS,
    Sampling type  --> 300 -- USE SAMPLING SCHEME
    Valuation mode  --> 1000 - ATTRIBUTIVE INSPECTION NON CONFIRMING UNITS
    (I have selected the system defined Sampling Scheme-> 252 ISO 2859-1 / Level II / multiple)
    Sampling scheme   -->      252       ISO 2859-1 / Level II / multiple( SYSTEM DEFINED)
    Determination rule    30        Use sampling scheme
    Sampling scheme       252  ISO 2859-1 / Level II / multiple
    Inspection severity -->  4   -  Normal inspection
       AQL value      -->      15.000
    THIS TABLE CONTAINS C1,D1;C2,D2;etc  --> System Defined.
    AS I have selected 252 - ISO 2859 -1/ Level II / multiple,
    all values of the above sampling scheme must be copied.
    It has calculated the sample size 40 for the sample lot 280 correctly
    --> sample size is 8
    5 samples are to be considered
    5 x 8 = 40 samples --> System calculated the 40 samples correctly
    SAMPLE LOT --> 280
    SAMPLE SIZE --> 8
    FIRST SAMPLE C1 --> 0 AND D1 --> 5;
    SECOND SAMPLE C2 --> 3 AND D2 --> 8
    THIRD SAMPLE C3--> 6 AND D3 --> 10
    FOURTH SAMPLE  C4 --> 9 AND D4 --> 12
    FIFTH SAMPLE --> C5 12 AND D4 --> 13
    I have not defined. I have selected the --> SAMPLING SCHEME 252,
    I feel that all its value have to be copied.
    Am I correct?
    Please advice.
    With Best Regards,
    Raghu Sharma

Maybe you are looking for