SSIS 2012: SSIS Error Code "Excel Connection Manager" failed with error code 0xC0202009.

Hi,
This is kind of weird issue that I am experiencing with excel connection manager in SSIS 2012. This issue occurs sometimes but when I close and re-open SSDT (SQL Server Data Tools - newer BIDS) then this issues goes off temporarily.
Just FYI, through SSDT environment I executed the package successfully with both settings Run64bit runtime setting to Yes and No when error does not occur.
So far I have installed
http://www.microsoft.com/en-us/download/details.aspx?id=13255 (Microsoft Access Database Engine 2010 Redistributable).
I still remember for older versions of SQL Server (2005 & 2008) that I have executed Excel connection SSIS packages with Run64bit runtime = false i.e. in 32-bit mode. As far as I know I think Excel 64-bit issue has been resolved with SQL Server
2012 release.
Here is the detail of error message:
TITLE: Package Validation Error
Package Validation Error
ADDITIONAL INFORMATION:
Error at Data Flow Task [Excel Source [2]]: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER.  The AcquireConnection method call to the connection manager "Excel Connection
Manager" failed with error code 0xC0202009.  There may be error messages posted before this with more information on why the AcquireConnection method call failed.
Error at Data Flow Task [SSIS.Pipeline]: Excel Source failed validation and returned error code 0xC020801C.
Error at Data Flow Task [SSIS.Pipeline]: One or more component failed validation.
Error at Data Flow Task: There were errors during task validation.
Error at Package [Connection manager "Excel Connection Manager"]: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x80004005.
An OLE DB record is available.  Source: "Microsoft Access Database Engine"  Hresult: 0x80004005  Description: "Unspecified error".
 (Microsoft.DataTransformationServices.VsIntegration)
Here are my environment details:
SQL Server 2012 {Microsoft SQL Server 2012 (SP1) - 11.0.3368.0 (X64) } , Excel 2010 (32-bit). I am developing SSIS code on Virtual desktops with Windows 7 32-bit OS.
Also it occurred to me that since Virtual Desktops are on Shared Infrastructure, the source files and SSIS packages (code) can be on Shared drives for e.g. \\<Corpnet>\userdata\<Corp_Users_Grp>\<Username>\Visual Studio 2010\Projects\Integration
Services Project2\Integration Services Project2\Package.dtsx.
Does this kind of Shared drives have any impact to give this issue?
Thanks in advance!
Ketan
P.S.: I had look at this forum question -->
http://social.msdn.microsoft.com/Forums/sqlserver/en-US/903bbe1d-e070-4c43-9d3b-0a5193550029/64bit-error-in-excel-connection-manager-in-ssis

Hi Arthur,
Thanks for your response.
Yes, it looks like SSIS still has bunch of issues with Excel files like as follows:
1) Some times excel source files cannot be parsed by excel source connection manager.
2) For derive column conversion, we can't replace the existing column. rather, we have to add the derived column as " add as new column" which is tough to manage  while destination mapping.
3) If an column in excel contains a data which is not of the data type assigned for the column in excel, the excel source reads that data as "null". For the same, we can't validate the data and redirect the erroneous data in reject file.  <-- For
this we tried IMEX setting also
4) In multi-tab/sheet excel file, excel source is unable to detect a tab and identify the metadata of the excel.
I am also checking Microsoft connect for Excel issues with SSIS 2012(https://connect.microsoft.com/SQLServer/SearchResults.aspx?SearchQuery=excel#&&PageIndex=22
As worst case scenario, I am thinking of converting Excel to CSV file or Flat text file. (http://www.mssqltips.com/sqlservertip/2772/importing-data-from-excel-using-ssis--part-2/).
Do you think it is advisable to convert Excel into CSV or Flat file.
Thanks,
Ketan

Similar Messages

  • [Load data from excel file [1]] Error: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009. There may be error messa

    Error
    [Load data from excel file [1]] Error: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER.  The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.  There
    may be error message
    I am using BIDS Microsoft Visual Studio 2008 and running the package to load the data from excel .
    My machine has 32 bit excel hence have set property to RUN64BITRUNTIME AS FALSE.
    But the error still occurs .
    I checked on Google and  many have used Delay validation property at Data flow task level to true but even using it at both excel connection manager and DFT level it doesnt work
    Mudassar

    Thats my connection string
    Provider=Microsoft.ACE.OLEDB.12.0;Data Source=E:\SrcData\Feeds\Utilization.xlsx;Extended Properties="Excel 12.0;HDR=NO";
    Excel 2010 installed and its 32 bit edition
    Are you referring to install this component -AccessDatabaseEngine_x64.exe?
    http://www.microsoft.com/en-us/download/details.aspx?id=13255
    Mudassar
    You can try an OLEDB provider in that case
    see
    http://dataintegrity.wordpress.com/2009/10/16/xlsx/
    you might need to download and install ms access redistributable
    http://www.microsoft.com/en-in/download/details.aspx?id=13255
    Please Mark This As Answer if it helps to solve the issue Visakh ---------------------------- http://visakhm.blogspot.com/ https://www.facebook.com/VmBlogs

  • Error: The AcquireConnection method call to the connection manager failed with error code 0xC0202009 using DB2 connection

    I have a SSIS project that I am newly running on the SQL server (2005) .  It was previously run on my PC.  I am importing data from a DB2 server to the SQL server.
    I am in the SA group on the server
    My connection to DB2 works
    When open the package and run it in preview mode, I can retrieve the data.
    When I execute the package I get the below errors:
    [MIDAS OLE DB Source [1]] Error: The AcquireConnection method call to the connection manager "NGMDSPA.alharris" failed with error code 0xC0202009.
    [DTS.Pipeline] Error: component "MIDAS OLE DB Source" (1) failed validation and returned error code 0xC020801C.
    What I have already done that has not worked:
    The original Protection level was set to EncryptSensitiveWithPassword. 
    I have reset the Package Password.
    I have set the protection level to DontSaveSensitive
    I saved the package on the server and set a Package Password.
    I created a new package, set the Protection level to DontSaveSensitive, set a package password in a configuration file using the Package Configuration Wizard.
    Error continues

    Yes.  The Drivers are installed and I have a successfull connection.  I am trouble shooting the issue on the server in BIDS.  I can connect to the DB2 server via the Connectionmanager.  I can also preview the data in the OLE
    DB source connection.  Therefore I know that I have a proper connection
    If you're setting option as DontSaveSensitive then you need to pass the connection information from configuration file/ config table. Otherwise it wont be able to use it for connecting to your source/destination servers. This is the recommended way as it
    will enable you to change connection info at runtime.
    If you want connection info to persist you need to use protection level as EncryptSensitiveUsingUserKey or EncryptSensitiveUsingPassword and set a password.
    Please Mark This As Answer if it helps to solve the issue Visakh ---------------------------- http://visakhm.blogspot.com/ https://www.facebook.com/VmBlogs

  • AcquireConnection method call to the connection manager Excel connection Manager failed

    I used VS Studio 2008 (BIDS version 10.50.2500.0) on an WinXp machine (v 5.1.2600 SP3 Build 2600) to create a package that writes multiple query results to different tabbed sheets of a single excel spreadsheet. The package was working just fine and has run
    successfully multiple times, but all of a sudden when opening the project, every single Data Flow task with an Excel Connection Manager displayed error icons. Each raises the following error message when attempting to open the Advanced Editor:
    SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005 Description: "Unspecified error". Error at DataFlow task name: SSIS error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method
    call to the connection manager Excel connection Manager failed with error code 0xC0202009. There may be error messages posted before this with more information on why the Acquire Connection method call failed. Exception from HRESULT: 0Xc020801c (Microsoft.SQlServer.DTSPipelineWrap)
    From the time I created the original package (when it worked fine) until now:
     1) I have been using the same computer, the same login account and the same permissions.
     2) I have been writing to the same (32 bit) 2010 Excel file (which I created) in a folder on my local machine.
     3) The filename and location have not changed; a template file is used each time to move and overwrite the previous file. Both are in the same locations.
     4) I can independently open the target Excel file and the template Excel files with no errors.
     6) The ConnectionString has not changed. The Connnection String I am using is
      Provider=Microsoft.ACE.OLEDB.12.0;Data Source=C:\Conversion\Conversion\Results_dt01.xlsx;Extended Properties="EXCEL 12.0 XML;HDR=YES;".
     7) Run64BitRuntime is set to False.
    8)  Delay Validation is set to true
    9) This is not running under a SQL job  
    10) There are no child packages being run
    I CAN create a NEW Excel Connection Manager, assigning it the exact same target Excel spreadsheet, successfully, but when I attempt to assign it to the Data Flow destination this error occurs:
    "Test connection failed because of an error in initializing provider. Unspecified error."
    Thinking that the driver might be corrupt, I opened a second SSIS package, which also uses the Excel Connection Manager (same driver) and this package continues to work fine on the same workstation with no errors.
    I have searched online for causes of this error for many hours and found nothing that helps me to solve this issue.
    Does anyone have any suggestions for me?

    Yes, I have verified that the Excel file is not in use or opened by anyone, including me. It has been two months since I opened this particular package, although I have been working with other packages in this project. I just discovered that another
    package in the same project has the same problem - all Data Flows that output to an Excel Destination now have the same error icons. This second packages outputs to an entirely different Excel file than in the first package.  A summay:
    Package #1 has error on every Excel Destination and uses templateA to overwrite fileA and then writes to fileA
    Package #2 has error on every Excel Desintation and uses templateB to overwrite fileB and then writes to fileB
    Package #3 has no error on any Excel Destination and is linked to multiple files (none are A or B)
    Package #1 and #2 are in the same project, but Package #3 is in a separate project .
    I will try replacing the Excel files with new ones for Package 1 and 2.

  • Error Command /usr/bin/codesign failed with exit code 1

    Hello everyone, I take this opportunity to greet and thank all in advance.
    I develop Android in for a long time and I just started trying with xcode. But I have this compilation error:
    Command /usr/bin/codesign failed with exit code 1
    I found it on google but nothing that I have solved the problem.
    Here is the error log:
    CodeSign /Users/paolotuttoilmondo/Library/Developer/Xcode/DerivedData/veneziawebcam-dbkg muothgsyigeuuxsxjflreufo/Build/Products/Distribution-iphoneos/veneziawebcam.app
    cd /Users/paolotuttoilmondo/Documents/Applications/veneziawebcam
    setenv CODESIGN_ALLOCATE /Developer/Platforms/iPhoneOS.platform/Developer/usr/bin/codesign_allocate
    setenv PATH "/Developer/Platforms/iPhoneOS.platform/Developer/usr/bin:/Developer/usr/bin:/u sr/bin:/bin:/usr/sbin:/sbin"
    /usr/bin/codesign --force --sign "iPhone Distribution: Paolo Tuttoilmondo" --resource-rules=/Users/paolotuttoilmondo/Library/Developer/Xcode/DerivedData/v eneziawebcam-dbkgmuothgsyigeuuxsxjflreufo/Build/Products/Distribution-iphoneos/v eneziawebcam.app/ResourceRules.plist --entitlements /Users/paolotuttoilmondo/Library/Developer/Xcode/DerivedData/veneziawebcam-dbkg muothgsyigeuuxsxjflreufo/Build/Intermediates/veneziawebcam.build/Distribution-ip honeos/veneziawebcam.build/veneziawebcam.xcent  /Users/paolotuttoilmondo/Library/Developer/Xcode/DerivedData/veneziawebcam-dbkg muothgsyigeuuxsxjflreufo/Build/Products/Distribution-iphoneos/veneziawebcam.app
    /Users/paolotuttoilmondo/Library/Developer/Xcode/DerivedData/veneziawebcam-dbkgm uothgsyigeuuxsxjflreufo/Build/Products/Distribution-iphoneos/veneziawebcam.app: CSSMERR_TP_NOT_TRUSTED
    Command /usr/bin/codesign failed with exit code 1
    My certificated Key:
    I think the problem is in the certificates
    I use Xcode 4.2.3
    Thanks in advance.
    Paolo

    Hello everyone, I solved the problem by me, I missed the certificate WWDR.
    Thanks

  • 2012 New Cluster Adding A Storage Pool fails with Error Code 0x8007139F

    Trying to setup a brand new cluster (first node) on Server 2012. Hardware passes cluster validation tests and consists of a dell 2950 with an MD1000 JBOD enclosure configured with a bunch of 7.2K RPM SAS and 15k SAS Drives. There is no RAID card or any other
    storage fabric, just a SAS adapter and an external enclosure.
    I can create a regular storage pool just fine and access it with no issues on the same box when I don't add it to the cluster. However when I try to add it to the cluster I keep getting these errors on adding a disk:
    Error Code: 0x8007139F if I try to add a disk (The group or resource is not in the correct state to perform the requested operation)
    When adding the Pool I get this error:
    Error Code 0x80070016 The Device Does not recognize the command
    Full Error on adding the pool
    Cluster resource 'Cluster Pool 1' of type 'Storage Pool' in clustered role 'b645f6ed-38e4-11e2-93f4-001517b8960b' failed. The error code was '0x16' ('The device does not recognize the command.').
    Based on the failure policies for the resource and role, the cluster service may try to bring the resource online on this node or move the group to another node of the cluster and then restart it.  Check the resource and group state using Failover Cluster
    Manager or the Get-ClusterResource Windows PowerShell cmdlet.
    if I try to just add the raw disks to the storage -- without using a pool or anything - almost every one of them but one fails with incorrect function except for one (a 7.2K RPM SAS drive). I cannot see any difference between it and the other disks. Any
    ideas? The error codes aren't anything helpful. I would imagine there's something in the drive configuration or hardware I am missing here I just don't know what considering the validation is passing and I am meeting the listed prerequisites.
    If I can provide any more details that would assist please let me know. Kind of at a loss here.

    Hi,
    You mentioned you use Dell MD 1000 as storage, Dell MD 1000 is Direct Attached Storage (DAS)
    Windows Server cluster do support DAS storage, Failover clusters include improvements to the way the cluster communicates with storage, improving the performance of a storage area network (SAN) or direct attached storage (DAS).
    But the Raid controller PERC 5/6 in MD 1000 may not support cluster technology. I did find its official article, but I found its next generation MD 1200 use Raid controller PERC H 800 is still not support cluster technology.
    You may contact Dell to check that.
    For more information please refer to following MS articles:
    Technical Guidebook for PowerVault MD1200 and MD 1220
    http://www.dell.com/downloads/global/products/pvaul/en/storage-powervault-md12x0-technical-guidebook.pdf
    Dell™ PERC 6/i, PERC 6/E and CERC 6/I User’s Guide
    http://support.dell.com/support/edocs/storage/RAID/PERC6/en/PDF/en_ug.pdf
    Hope this helps!
    TechNet Subscriber Support
    If you are
    TechNet Subscription user and have any feedback on our support quality, please send your feedback
    here.
    Lawrence
    TechNet Community Support

  • IPhone - Build error: Command /usr/bin/codesign failed with exit code 1

    Hi
    can anyone help with error i'm getting when trying to get my iphone ready for distribution
    some post say to look at the keychain for more than one iphone distribution key but i'm only have one for distribution and one for development..
    anyone have any ideas??
    Regards

    question ?
    in the developer.apple.com and clicking on App id you can see the full ID plus .com.Name.AppName
    is this what should be in the info.plist (bundle Identifier)?
    have wiped my mac and started a fresh and just getting this error
    but can't find what the error means have done the guide step by step
    any further pointer would be helpful
    regards
    Tony

  • Creating a Linked Report in SC 2012 - Operations Manager fails with Error

    Hello everyone,
    I was trying to create a linked report based on an availability report recently. I found Emre Guclu's scom linked report creation guide here:
    http://blogs.technet.com/b/emreguclu/archive/2011/10/13/using-linked-reports-in-scom-to-create-custom-availability-reports-for-specified-monitors.aspx
    I go to SSRS web console and select a report (Which is Microsoft.SystemCenter.DataWarehouse.Availability in Microsoft.SystemCenter.Datawarehouse.Reports), select "Create a Linked Report" from context menu, select another location for storing the
    report just like on this guide but i get an error rsWrongItemType with exact text:
    "The operation you are attempting on item ' Microsoft.SystemCenter.Datawarehouse.Reports/ Microsoft.SystemCenter.Datawarehouse.Availability' is not allowed for this item type. rsWrongItemType"
    Does anyone know why is this error happening and better how to fix this?
    Below is the screenshot of SSRS.

    Hi,
    Please check the report path you have set, the location must specify the full report path, such as
    /custom report folder/MyReport.
    Alex Zhao
    TechNet Community Support

  • Download Manager - failing with error 400 Bad Request

    Each time I try to download some patches from the download basket I get this error: The request failed: 400.  Download Manager says the files are Partially Downloaded but the downloads never complete (they just cycle round one after another attempting each download before failing).  The connection to SAP ssems to be made correctly (see trace file extract below)
    I'm running JRE version 1.4.2_12; download manager ver 2.1.130.  I've tried uninstalling & reinstalling JRE & download manager (numerous times).  Does anyone have any suggestions about what might be the cause?
    Thanks, Chris
    PS - This is the relevant part of the trace file:
    24-Aug-2007 09:29:06   Opening connection to 'https://smpdla.sap.com:443/00000084/217/KGPHA68.CAR?object_id=011000358700000405252007E&filepath=00000084\217\KGPHA68.CAR&uid=S0003245349'
    24-Aug-2007 09:29:06   Sending request to SAP Service Marketplace Server (no tunneling)
    24-Aug-2007 09:29:13   A response was received from the SAP Service Marketplace Server.
    24-Aug-2007 09:29:13   Response received: 400 Bad Request
    24-Aug-2007 09:29:13   Response Http Headers:
    24-Aug-2007 09:29:13      Server=AkamaiGHost
    24-Aug-2007 09:29:13      Mime-Version=1.0
    24-Aug-2007 09:29:13      Content-Type=text/html
    24-Aug-2007 09:29:13      Content-Length=340
    24-Aug-2007 09:29:13      Expires=Fri, 24 Aug 2007 08:28:49 GMT
    24-Aug-2007 09:29:13      Date=Fri, 24 Aug 2007 08:28:49 GMT
    24-Aug-2007 09:29:13      Connection=close
    24-Aug-2007 09:29:13   Response code: 400
    24-Aug-2007 09:29:18   Notifying subscribers of download state ...
    24-Aug-2007 09:29:18   The download has terminated ...
    24-Aug-2007 09:29:18   getUserProxy: true
    24-Aug-2007 09:29:18   getEffectiveProtocol: http
    24-Aug-2007 09:29:18   detected: http / https w/o proxy request
    24-Aug-2007 09:29:18   SMPResponse::sendRequestNormal
    24-Aug-2007 09:29:18   Opening connection to 'http://service.sap.com:80/~form/download_basket?_MODE=OBJECT_VERSION&OBJID=011000358700000485532007E&'
    24-Aug-2007 09:29:18   Sending request to SAP Service Marketplace Server (no tunneling)
    24-Aug-2007 09:29:25   A response was received from the SAP Service Marketplace Server.
    24-Aug-2007 09:29:25   Redirecting to 'https://WEBSMP108.SAP-AG.DE/~form/download_basket?_MODE=OBJECT_VERSION&OBJID=011000358700000485532007E&'...
    24-Aug-2007 09:29:25   getUserProxy: true
    24-Aug-2007 09:29:25   getEffectiveProtocol: https
    24-Aug-2007 09:29:25   detected: http / https w/o proxy request
    24-Aug-2007 09:29:25   SMPResponse::sendRequestNormal
    24-Aug-2007 09:29:25   Opening connection to 'https://WEBSMP108.SAP-AG.DE/~form/download_basket?_MODE=OBJECT_VERSION&OBJID=011000358700000485532007E&'
    24-Aug-2007 09:29:25   Sending request to SAP Service Marketplace Server (no tunneling)
    24-Aug-2007 09:29:25   A response was received from the SAP Service Marketplace Server.
    24-Aug-2007 09:29:25   Response received: 200 OK
    24-Aug-2007 09:29:25   Response Http Headers:
    24-Aug-2007 09:29:25      Date=Fri, 24 Aug 2007 08:29:02 GMT
    24-Aug-2007 09:29:25      Server=Microsoft-IIS/6.0
    24-Aug-2007 09:29:25      Content-Type=text/plain
    24-Aug-2007 09:29:25      Content-Length=44
    24-Aug-2007 09:29:25   getUserProxy: true
    24-Aug-2007 09:29:25   getEffectiveProtocol: http
    24-Aug-2007 09:29:25   detected: http / https w/o proxy request
    24-Aug-2007 09:29:25   SMPResponse::sendRequestNormal
    24-Aug-2007 09:29:25   Opening connection to 'http://service.sap.com:80/~form/download_basket?_MODE=DOWNLOAD_START2&OBJID=011000358700000485532007E&_VERSION=2.1.130&'
    24-Aug-2007 09:29:25   Sending request to SAP Service Marketplace Server (no tunneling)
    24-Aug-2007 09:29:25   A response was received from the SAP Service Marketplace Server.
    24-Aug-2007 09:29:25   Redirecting to 'https://WEBSMP209.SAP-AG.DE/~form/download_basket?_MODE=DOWNLOAD_START2&OBJID=011000358700000485532007E&_VERSION=2.1.130&'...
    24-Aug-2007 09:29:25   getUserProxy: true
    24-Aug-2007 09:29:25   getEffectiveProtocol: https
    24-Aug-2007 09:29:25   detected: http / https w/o proxy request
    24-Aug-2007 09:29:25   SMPResponse::sendRequestNormal
    24-Aug-2007 09:29:25   Opening connection to 'https://WEBSMP209.SAP-AG.DE/~form/download_basket?_MODE=DOWNLOAD_START2&OBJID=011000358700000485532007E&_VERSION=2.1.130&'
    24-Aug-2007 09:29:25   Sending request to SAP Service Marketplace Server (no tunneling)
    24-Aug-2007 09:29:26   A response was received from the SAP Service Marketplace Server.
    24-Aug-2007 09:29:26   Response received: 200 OK
    24-Aug-2007 09:29:26   Response Http Headers:
    24-Aug-2007 09:29:26      Date=Fri, 24 Aug 2007 08:29:03 GMT
    24-Aug-2007 09:29:26      Server=Microsoft-IIS/6.0
    24-Aug-2007 09:29:26      Content-Type=text/html
    24-Aug-2007 09:29:26      Content-Length=2416
    24-Aug-2007 09:29:26   Number of URLs: 1
    24-Aug-2007 09:29:26   Description lines: 56
    24-Aug-2007 09:29:26   Adding HTTP1/1 Header: Range: bytes=0-*
    24-Aug-2007 09:29:26   getUserProxy: true
    24-Aug-2007 09:29:26   getEffectiveProtocol: https
    24-Aug-2007 09:29:26   detected: http / https w/o proxy request
    24-Aug-2007 09:29:26   SMPResponse::sendRequestNormal
    24-Aug-2007 09:29:26   Opening connection to 'https://smpdla.sap.com:443/00000085/652/KGPHA69.CAR?object_id=011000358700000485532007E&filepath=00000085\652\KGPHA69.CAR&uid=S0003245349'
    24-Aug-2007 09:29:26   Sending request to SAP Service Marketplace Server (no tunneling)
    24-Aug-2007 09:29:33   A response was received from the SAP Service Marketplace Server.
    24-Aug-2007 09:29:33   Response received: 400 Bad Request
    24-Aug-2007 09:29:33   Response Http Headers:

    Yes - I've checked the address w're pointing to & have rechecked several times with our network people re: the proxy.
    The trace seems to show that we're certainly making the initial connections to SAP OK - it just gives up after a few redirections.
    Chris

  • Excel Connection Manager suddenly can no longer connect to Excel from SSIS package

    <p>During the last 3 months, I used 32 bit SSIS 2008 (v 10.50.2500.0) on an WinXp machine (v 5.1.2600 SP3 Build 2600) to create a package that writes multiple query results (reports) to an excel spreadsheet. Each report is written to a different
    tabbed sheet in the same spreadsheet. </p><p>The package was&nbsp;working just fine until May 9 2013, when suddenly every single&nbsp;Data Flow task with an Excel Destination&nbsp;displayed error icons and raised the&nbsp;following
    error message when opening the Advanced Editor:</p><p>SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005 Description: "Unspecified error". <br />Error at &lt;DataFlow task name&gt;: SSIS
    error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager &lt;Excel connection Manager&gt; failed with error code 0xC0202009. There may be error messages posted before this with more
    information on why the Acquire Connection method call failed. Exception from HRESULT: 0Xc020801c (Microsoft.SQlServer.DTSPipelineWrap)</p><p>Originally the error message reported that the Error Code was "0x8000FFFF", but I can't seem
    to reproduce that error code since. Now I am only getting the above error message.</p><p>From the time I created the original package (when it worked fine) until now, I have been using the same computer, writing to a (32 bit) 2010 Excel file in
    a local folder. The filename and location have not changed. The ConnectionString has not changed. The Connnection String I am using is Provider=Microsoft.ACE.OLEDB.12.0;Data Source=C:\Conversion\Conversion Results_dt01.xlsx;Extended Properties="EXCEL
    12.0 XML;HDR=YES;". </p><p>Now an attempt to create and test a NEW Connection Manager yields me this error. "Test connection failed because of an error in initializing provider. Unspecified error.",&nbsp; whereas before I had
    no problems creating a new connection manager.</p><p>I checked a second SSIS package, which I also built during the past 3 months, which loads multiple sheets from multiple Excel files to a SQL Server 2008 database holding table. It uses the same
    ACE OLE DB 12.0 connection to load the Excel speadsheets and this package continues to work fine on the same workstation.</p><p>In desparation, wondering if the Microsoft ACE OLE DB 12.0 driver had become corrupt (even though the second package
    was raising no errors), I did download and install the Microsoft ACE OLE DB 12.0 driver.&nbsp; That did not solve my problems with the first package.</p><p>I need to get this package running again ASAP as it is targeted for UAT testing in a
    matter of days. Any help with this issue would be greatly appreciated!</p>

    I submitted this issue above and now I am having the same problem again. I am using the same local computer, the same operating system (WinXp v 5.1.2600 SP3 Build 2600) as originally described. I am working with the same SSIS package that
    writes multiple query results (reports) to an excel spreadsheet. This package has been successfully executed multiple times, but now I am suddenly getting the same error as follows:
    Error at 1ConversionContacts [Connection manager "Excel Connection Manager"]: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x80004005.
    An OLE DB record is available.  Source: "Microsoft Access Database Engine"  Hresult: 0x80004005  Description: "Unspecified error".
    Error at DFlow Write soft deleted duplicate claims to Excel sheet [Excel Destination - write duplicate claim nbrs that have been removed to Excel [61]]: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER.  The AcquireConnection method
    call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.  There may be error messages posted before this with more information on why the AcquireConnection method call failed.
    The package will not run because of these multiple errors (multiple because it occurs on every single excel destination in the package).
    I have Run64BitRuntime set to false on the project. I have triple checked that the excel file name (which I created and can access) exists with the correct name in the correct path, which is local on my machine. The file is the same file in the same
    location as when the package worked.  I am running the SSIS service under my own network login, as I was when the package worked. I have been consistently getting this same error whenever I change my network password without updating the password
    in the SSIS service, but I have triple verified that the service is using my latest password. If I try to open and edit the Excel Destination in any DataFlow task I get the same error. I can successfully create a new Excel Connection Manager pointing
    to the same excel file. However if I try to assign the newly created Excel Connection Manager in the data flow, I cannot activate the drop down to choose the Excel sheet without getting an 'Unspecified error' message. I then swapped out
    the file with its template version, and ensured the name was updated as correct. I still get the same errors.
    Oh, and the SSIS package is extracting data from a SQL Server 2008 database with an ADO.net Connection Manager using Windows authentication. I have no problems with the SQL Server connection, it has always worked and still does.  It is only
    the connection to excel output file which is locally stored on my machine.
    Has anyone got any suggestions for me?

  • Sql server agent job failing to connect excel connection manager of SSIS package by 32-bit mode run time

    I am unable to succeed with sql agent job, I am trying to execute the SSIS package through sql agent job by ticking 32 bit runtime check box in 64 bit machine , even it does not worked..
    could any one helpme on this?
     Source: Excel Load Connection manager "Excel Connection Manager"    
    Description: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x80040154.  An OLE DB record is available.  Source: "Microsoft OLE DB Service Components"  Hresult: 0x80040154  Description: "Class
    not registered".  End Error   TS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER.  The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.  There may be error
    messages posted before this with more information on why the AcquireConnection method call failed.  End...  The package execution fa...  The step failed.

    Hello Keerthi,
    Can you please modify settings and set delay validation for Excel connection manager? I think its validating connection and failing because it might be picking that from some variable.
    Alternatively, please run package using below and see what happens.
    EXEC master..xp_cmdshell 'DTEXEC.exe /SQL "Folder\Package" /SERVER Servername'
    I will recommend you to follow steps in below link.
    http://www.sqlhammer.com/blog/running-ssis-packages-in-32-bit/
    Regards,
    Vishal Patel
    Blog: http://vspatel.co.uk
    Site: http://lehrity.com

  • Step by Step Instructions of loading Excel into SSIS via OLE Data Source Microsoft.ACE instead of Excel connection manager

    Hi,
    I have a very large Excel workbook which I need to load into SSIS. Using the default Excel connection manager SSIS seems to load the entire work sheet into memory before performing any operation even after setting IMEX=1 within the connection string.
    Can anyone provide me with step by step instructions on how to use  OLE Data Source Microsoft.ACE please?
    I've found the link; -
    https://www.connectionstrings.com/ace-oledb-12-0/
    Which looks very useful.
    Since I currently have Excel 2010 as my data source I tried; -
    Data Source=C:\PoC\POC_Data_Source\my.xlsx;Provider=Microsoft.ACE.OLEDB.12.0;Extended Properties="Excel 12.0 Xml;HDR=YES ;IMEX=1";
    The connection test successfully. However SSIS still seems to be loading the entire work sheet into memory before starting the data load.
    Kind Regards,
    Kieran.
    Kieran Patrick Wood http://www.innovativebusinessintelligence.com http://uk.linkedin.com/in/kieranpatrickwood http://kieranwood.wordpress.com/

    Thanks again Koen,
    I am developing remotely on a development server. So when I run SSDT I am running it within the development server box. My current technology / environment mix means I can't run SSDT from my local desktop.
    I am pretty sure that scanning of the rows is an issue causing performance, e.g. if I just click on the data source component SSDT freezes for several minutes, unless I just have a cut down version of the Excel file, say first 5,000 rows, then the response
    of SSDT is acceptable.
    Also when I have SSDT pointing to the full spreadsheet and I click around in the associated Data Flow I notice devenv.exe* 32 slowing grabbing 4gb of RAM and releasing it according to Windows Task Manager. 
    Kind Regards,
    Kieran.
    Kieran Patrick Wood http://www.innovativebusinessintelligence.com http://uk.linkedin.com/in/kieranpatrickwood http://kieranwood.wordpress.com/

  • Excel connection manager - Error after Installing Office 2013

    Hi Team,
    My SSIS package used to work fine until I Upgraded my Office 2010 to Office 2013. After upgrading to 2013, the SSIS package which is created using SQL 2012 is throwing error for Excel Connection manager. Below is the error what I see
    TITLE: Microsoft Visual Studio
    Could not retrieve the table information for the connection manager 'Excel Connection Manager'.
    Failed to connect to the source using the connection manager 'Excel Connection Manager'
    BUTTONS:
    OK
    FYI, I am running the package with Run64BitRunTime property = False.
    Do let me know the solution please. It will be of great help as we are proposing this tool in a migration project.

    I found the solution. Thanks
    You don't need office on your server (not recommended and not supported). You should install
    Microsoft Access Database Engine 2010 Redistributable for excel (xlsx) files and then use the Excel
    This download will install a set of components that facilitate the transfer of data between existing Microsoft Office files such as Microsoft Office Access 2010 (*.mdb and *.accdb) files and Microsoft Office Excel 2010 (*.xls, *.xlsx, and *.xlsb) files to
    other data sources such as Microsoft SQL Server. Connectivity to existing text files is also supported. ODBC and OLEDB drivers are installed for application developers to use in developing their applications with connectivity to Office file formats.

  • SCCM Client Instalaltion failed with error code 1624

    Folks,
    I am getting clients installation failed exit code 1624 and
    CcmSetup failed with error code 0x80070658

    - Check the access to the adminshare from the SCCM server
    \\computer\admin$ 
    - Run the wbemtest.exe to see if you can connect to the systems namespace
    - Verify DNS records on your DNS server
    - Renew dns
    Ipconfig /flushdns
    Ipconfig /registerdns
    Kind regards,
    Tim
    MCITP, MCTS, MCSA
    http://directoryadmin.blogspot.com
    This posting is provided 'AS IS' with no warranties or guarantees and confers no rights.
    "If this thread answered your question, please click on "Mark as Answer"

  • Task Sequence has failed with error code: 0x80070570

    I've created task sequence for Windows XP OS Deployment. WinPE boot image loads successfully, Partitions are formatted successfully too. But during "Applying image 1 from volume C:\" I receive following error:
    Task Sequence: My_task_sequence_name has failed with error code: 0x80070570.
    What I need to do? Any ideas? (My computer has following details: ASUS P5KSE motherboard, Core 2 Duo, SATA HDD, Atheros L1 adapter)

    No, a build and capture task sequence automates the build of the image removing any and all human intervention so that rebuilding or refreshing an image becomes a simple matter. Building images by actually manually installing Windows is anti-IT.
    File corruption can be caused by many, many things; e.g., anti-virus, physical disk errors, network transmit errors, etc.
    Jason | http://myitforum.com/cs2/blogs/jsandys | http://blogs.catapultsystems.com/jsandys/default.aspx | Twitter @JasonSandys

Maybe you are looking for

  • Queue SYSFAIL after message split "Whole number overflow on addition"

    Hi, I'm using a message mapping in PI 7.1 to split a message in several messages for each line of an invoice. It's a mapping 1 to 0..n. Everything went well since I had maximum 100 invoice lines to split (then 100 messages at the output of the mappin

  • Install stops at updating component registration

    Hi I am trying to install itunes on a new Windows XP Pro machine. It gets to the updating component registration and seems to just stop. I have left now for a few hours and it has only advanced by one bar. At this rate it will take a week to install.

  • Unable to detect Adobe Acrobat during Livecycle install ?

    Hi All, I'm having problem in Windows Server 2008 R2 64 edition install of Adobe Live Cycle Enterprise Server 2.5 with Weblogic as the Webserver (the previous reason of not using JBoss simply because of it doesn't work with SQL Server 2008 Standard R

  • After updating, I receive a not responding message, and then it freezes

    after upgrading to firefox 6, I now continuously receive a "not responding" message at the top of page, and it freezes. I have disabled all add ons, but connot run some things. I have a lot of trouble playing games on facebook, because it freezes up

  • Help! Flashvars causing browser slow down

    Hi All, I have a very simple .swf file that is causing some kind of slow down or memory leak. It is effecting the browser its self as moving the mouse cursor around or selecting text becomes sluggish. Within the .swf, the stage is only 1px by 1px. It