Steps to upgrade Cisco MDS core switch

Hello,
We wanted to upgrade our Cisco SAN core switch firmware. Currently we are running below firmware version. We wanted to go to latest version NX OS 5.2 (x) but as per the white paper i need to go to 5.0 (X) and after that i need to upgrade it to 5.2 (x). Can some help me with the steps to follow the upgrade. I have th cook book but just need the main steps to perform the upgrade.
kickstart: version 4.1(1c)
  system:    version 4.1(1c)

are you using IVR non-NAT, if you are you need to convert to IVR-NAT before you go to 5.2. Other than that you just follow the  normal procedure, look at the release notes for each firmware to make sure your hardware is supported and then do the usual
install all system bootflash:m9x00-xxx.bin kickstart bootflash:m9x00-xxx-kickstart-xx.bin
as a side note, i know you don't mark people replies to your questions as helpful/correct on EMC ECN ..at least do it here to show your appreciation.
@dynamoxxx

Similar Messages

  • Cisco MDS 9418 switch doubt

    Hi Team,
    We have an issue, whether the cisco MDS 9418 switch supports FCIP feature.
    We are planning to migrate the data from our old data center over WAN to the EMC VNX storage box in other location.
    In our old data center we have 2 FC cisco switches connected to the EMC clariion storage array. Inorder to replicate data from clariion box to EMC VNX box over WAN ,it can be done via FCIP.
    I wanted to know if we can use insert the FCIP converters into these MDS 9418 switch or do we need to have separate FCIP converters.
    Do we need FCIP converters on both sides for doing replication over FCIP.
    For clear understanding please see the attachment.
    Will waiting for your response......
    Regards,
    Pranav.

    Hi,
    Since the 9148 does not have IP interfaces, something will be needed to tunnel the FC into IP (FCIP) such as an MDS 9222i, which has both FC interfaces and GigE interfaces and supports FCIP.
    Regards,
    David

  • Cisco MDS series switch details

    Hello I 'm new to CISCO  Switch world.
    I 'm working as Clariion Admin and have have taken up the responsibilty to manage switches.Since,i am a novice i need little guidance on how work on cisco switches.I know the Zoning (how zoning done on MDS 9000 series switches) part ,but would like to venture deep into the details on CISCO MDS series switches.
    Like, the use of Port channels etc.
    Will really appreciate if some one can help me with a link or place ( not the configuration guide) where in i can find details on concentrated more on the theory part .
    Thanks in advance!

    Actually the best info is in the configuration guides.  There are some external companies that run training sessions on the MDS to provide in depth training.  There is the MDS cookbook available on CCO that is also a good point of information.    If you search on 'MDS white papers' after you login into Cisco.com, there are several good documents that might meet your needs.
    Hope this hels,
    Mike

  • Does cisco MDS 9000 switch by default set a little higher R_T_TOV?

    Hi, All:
    Not sure anyone has done LOS for cisco MDS 9000 switch before. I tried to insert code violation which is equal to 103ms but only see link reset but not NOS/OLS. is it because that Cisco MDS has default higher ? Or can we set R_T_TOV on switch?

    Hi Larry - [this|http://lists.apple.com/archives/usb/2008/Oct/msg00021.html] was the only thing I could find about transactions timing out, but since you don't have anything plugged in, it really doesn't apply. Have you tried resetting your SMU?
    If that doesn't work, run Disk Utility from your install disc and see what it comes up with. Your suspicion that the MB may be faulty is probably correct, and if you are still within the 90 day warrant period, you should call the repair place and have them replace it yet again.

  • Using Cisco MDS 9148 switch for switching and routing

    Hi Gurus,
    Can you please advice me! Can i configure interface trunking, routing and dhcp services on the Cisco MDS 9148 switch?
    Thanks for your response!!

    Tommy,
    MDS9148 is a Storage SAN Fibre Channel switch, it doesn't support Ethernet, IP, VLANs, VLAN trunking, 802.1Q, IP routing, DHCP. It's meant for Fibre Channel connectivity between Fibre Channel server HBAs and Fibre Channel storage.
    Roman

  • Configuring Radius server with Cisco MDS - 9606 switch

    Need help in configuring Radius server with cisco MDS - 9606
    please let me know if any document available

    rtt min/avg/max/mdev = 0.260/0.327/0.468/0.077 ms
    IFCBCCEMCSW2# sh version
    Cisco Storage Area Networking Operating System (SAN-OS) Software
    TAC support: http://www.cisco.com/tac
    Copyright (c) 2002-2008, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained herein are owned by
    other third parties and are used and distributed under license.
    Some parts of this software may be covered under the GNU Public
    License or the GNU Lesser General Public License. A copy of
    each such license is available at
    http://www.gnu.org/licenses/gpl.html and
    http://www.gnu.org/licenses/lgpl.html
    Software
    BIOS: version 1.1.0
    loader: version 1.2(2)
    kickstart: version 3.3(1c)
    system: version 3.3(1c)
    BIOS compile time: 10/24/03
    kickstart image file is: bootflash:/m9500-sf1ek9-kickstart-mz.3.3.1c.bin
    kickstart compile time: 5/23/2008 19:00:00 [06/19/2008 23:56:56]
    system image file is: bootflash:/m9500-sf1ek9-mz.3.3.1c.bin
    system compile time: 5/23/2008 19:00:00 [06/20/2008 00:26:51]
    Hardware
    cisco MDS 9506 ("Supervisor/Fabric-1")
    Intel(R) Pentium(R) III CPU with 1028596 kB of memory.
    Processor Board ID JAB094300ER
    bootflash: 250368 kB
    slot0: 0 kB

  • How to configure an external Cisco MDS 9124 Switch

    I have worked with some other Fibre switches before but not Cisco and was wondering if someone can pass me some quick info on how to configure the MDS 9124. I saw the Quick Guide and it briefly talked about config, but do I have to go thru hyperterminal to do the initial IP config? Is there a default one already I can use to get to the WebGUI. Some of the ones I worked with (like the ones that come with the Bladecenter) have a default IP, where I can enter the IP into the web browser and access the GUI right away and start doing configs.
    With the MDS 9124, can I do this? Or do I have to configure IP thru hyperterminal and then install Fabric Manager etc.
    Thanks in advance for any help!

    I assume that you actually read the guide:
    http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/hw/9124/quick/quide/9124QSG.html
    Setup of the network is pretty clear. If the switch is brand new, you have to give it an IP address. Generally just follow the dotted line and don't vary except if you know what you are doing.
    Once its on the network, DM and FM can do the rest.
    The 9124e's don't have serial ports so the OA looks after that for you.

  • Layer 2 trunk ports went down due to cisco 4500 core switch !!!

    Hi Everyone,
    My 2 Layer 2 2960 switchTrunk Ports went down due to cisco 4500 switch. It happening everytime . I rebbot the switch 4500 . then problem disappears but after sometime facing same issue.
    Please help.

    My 2 Layer 2 2960 switchTrunk Ports went down due to cisco 4500 switch. It happening everytime . I rebbot the switch 4500 . then problem disappears but after sometime facing same issue.
    Hmmmm ... You won't be able to determine anything if you won't provide any addition information.  I mean what do you mean by "went down"?  Did the port go into "error disable"? 
    If it went into error disable, console in both switches and post the output to the command "sh interface status err".

  • How to keep a Fabric port always enable in a Cisco MDS 9000 Switch?

    Dear members:
    I work in Datacenter automation solutions using most part of time Virtualization softwares.
    I'm having an interst problem with a server while it is booting thru SAN using a logical volume stored in a EMC DMX4 array.
    We are trying to boot a VMWare ESX 4.1 OS, but when OS tries to change HBA BIOS driver to ESX device driver during boot process, the Server's HBA logged off from MDS Fabric that it is connected, ESX can't boot and I got a ESX standard prompt.
    I think that problem is becuase ESX 4.1 is taking too long to load Storage Drivers during boot process and the consequences is HBA logged off from Fabric.
    I already tried to change FLOGI parameters in HBA and Topology architecture, but I didn't have success.
    If a try to boot a Microsoft OS like Windows 2008, I don't have this behavior, and OS can boot from SAN without any problem.
    Please, if anyone have any idea about how to keep fabric port always enabled, let me know. Any idea or help is very welcome.
    Best Regards.
    Alexandre Nicolau

    Hi,
    You can take a look at this document:
    http://www.cisco.com/en/US/docs/solutions/Enterprise/WAN_and_MAN/QoS_SRND_40/QoSCampus_40.html#wp1099352
    Hope this helps, please rate if it does.
    Kind regards,
    - Adrian.

  • Cisco MDS 9509 and HP Blade server problem

    I have a big problem , when i connected to MDS 9509 to HP VC-FC 8GB the module in MDS 9509 did not detect the HP module . I think this will be because MDS 9509 uses VSAN technology , but HP blade is not support this feature. Please help me

    I am fairly certain that the HP blade chassis has HP branded Brocade FC switches. These switches need to be placed into AG mode and rebooted. On the Cisco MDS core the NPIV feature must be enabled.
    Here is more info on the Brocade AG mode -
    http://www.brocade.com/solutions-technology/technology/platforms/fabric-os/access_gateway.page
    http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/AccessGateway_DS_02.pdf
    Cisco NPIV info
    http://www.cisco.com/en/US/prod/collateral/ps4159/ps6409/ps5989/ps9898/white_paper_c11-459263.html

  • Cisco MDS 9148 compatibility with Finisar FTLF-8524-P2BNV SFP+

    Hello,
    I have a Cisco MDS 9148 switch with Finisar FTLF-8524-P2BNV SFP+ modules. I am told by the guys configuring the equipment that these modules are not identified in the switch interface.
    I am curious if there could be a compatibility problem (I have not found a compatibility list) or any other issue which could cause the behaviour.
    Thank you

  • Core switches between 2 data centers

    Existing data center has 2 X Cisco 6500 series core switches, new data center has 2 X Cisco nexus core switches. For the connection between 2 data center, it will be using leased line. To establish the network connection for both side, should it use trunk port with layer 2 connection directly or layer 3 ip routing (configure the ip on switchport interface) ? What is the better approach for its design? Please share your idea.

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    Normally, when dealing with off-site traffic, L3 is better as it limits traffic to only what needs to go off-site.
    However, as you're dealing with data centers, it's no longer uncommon that there's need to share L2 between them.  So, much depends on what your needs are.

  • Step-by-step guide to upgrading a MacBook Core Duo from 802.11g to 802.11n.

    Hardmac.com has post a step-by-step guide on how to upgrading a MacBook Core Duo from 802.11g to 802.11n using an 802.11n card from the Mac Pro desktop. The upgrade was also tested and confirmed to work with the AirPort Extreme 802.11n at 802.11n speed.
    There is no reason that a similar upgrade shouldn't also work with the MacBook Pro.
    http://www.hardmac.com/articles/71/

    Hardmac.com has post a step-by-step guide on how to
    upgrading a MacBook Core Duo from 802.11g to 802.11n
    using an 802.11n card from the Mac Pro desktop. The
    upgrade was also tested and confirmed to work with
    the AirPort Extreme 802.11n at 802.11n speed.
    There is no reason that a similar upgrade shouldn't
    also work with the MacBook Pro.
    http://www.hardmac.com/articles/71/
    Gino,
    Interesting how the Apple 802.11n Enabler installed on the MacBook with no problems using the CD that comes with the AirPort Express.
    I must try that.
    Thanks for the post!
    William

  • Scsi device discovery in Cisco MDS switches

    I was using this device discovery to find out how many luns can be seen on that server.
    I tried to use discover scsi-target command and it does not give much useful information. and I do not want to add the OS WWNS on my LUN security in addition to HBA WWNS for the host group on the array end.
    The problem that I am having is that I can see 7 LUNs out of 9 when I connect to Cisco MDS where as in brocade I can see all the LUNs.
    I checked the LUN security and zoning and everything seems to be correct.
    If Cisco SAN OS has commands where by I can see what LUNs can be seen on the switch, that would be really helpful. But It looks like LUN/LDEV info cannot be seen through discover command.
    Please let me know how to troubleshoot this problem
    Thanks

    In the array, I tried to add switch wwn to the LUN Security and zoned the same switch wwn on the MDS. Is there anything I am missing. Thanks in advance
    But still I could not see any LUNs. When I do discover command, NLUNS shows 0.
    and the command sh scsi-target lun os win shows nothing.
    discover scsi-target vsan 21 fcid 0xea000b os win
    VSAN: 21 FCID: 0xea000b
    PRLI RSP: 0x01 SPARM: 0x0012
    SCSI TYPE: 31 NLUNS: 0
    Vendor: HITACHI Model: DISK-SUBSYSTEM Rev: 5007
    Other: 7f:00:03:12:cf:00:00:02

  • Dedicated supervisor engine slot numbers for cisco core switches

    I want to know why there is  Dedicated supervisor engine slot numbers in core switch.
    Feature
    Cisco Catalyst WS-C4503-E Chassis
    Cisco Catalyst WS-C4506-E Chassis
    Cisco Catalyst WS-C4507R+E Chassis
    Cisco Catalyst WS-C4510R+E Chassis
    Dedicated supervisor engine slot numbers
    1
    1
    3 and 4
    5 and 6 
    Please make it clear why its dedicated slot alocate for supervisor engine slot

    Hi,
    I think the reason behind a dedicated slots for Supervisors of 4500/6500 chasis is due to the architectural constraints.
    For example the Sup 720 in 6500 has 18 fabric channel (18 connections to the fabric), the line cards have only 1/2 fabric channels depending on their version. So if you have to make a supervisor independent of the slot you need to have 18 backplane  fabric channels in each slot of the chassis for the SUP to work in all slots as compared to 1/2 backplane fabric channels per slot as we have right now for the line cards. Almost same should go for the 4500. And this might come across as an architectural constraint. This is the best explanation i can think of.
    Thanks
    "Please rate the post if found useful"

Maybe you are looking for

  • IPod nano 3rd Gen & i-Station3

    I have an i-Station3 from Logic3. It always worked with my iPod nano 2nd gen, but it don't accept de new generation while they both have the same docking station. Is there a solution for this? Maybe a software update for the iPod or something? Thanks

  • What's a good place to discuss hardware selection?

    Hi, I have read various documents on the Adobe site, but I am still confused about hardware selection for Photoshop and Premiere. Is there a good place on the forums to discuss that? I saw one question on this forum asked a while ago, but it got no r

  • Itunes will not sync photos - itl file corrupt

    Hello All, I recently upgraded to Windows 7 from XP.  The XP install had my drive partitioned and my itunes data was on the E drive.  Now with Windows 7 I have one partition (C) and I was able to restore everything from Itunes to the new drive.  All

  • Regarding SET TITLEBAR in normal ABAP report

    Hi All,     I  wnat to know the  use of SET TITLEBAR command in ABAP report . i have searched the forum but i am not find any sutable answers. for what purpose we  use the SET TITLEBAR in normal ABAP report. Regards CB

  • Hyper-V Manager missing from tools menu

    I've just installed a new domain. It has one domain controller (Windows Server 2012 R2), SVR0 and one Hyper-V Server (not the Hyper-V role...Hyper-V Server), SVR1. I joined SVR1 to the domain and now I wan to manage it from a Windows 8.1 client. I've