Test Stand 2010 Deployment tool Error

Dear All,
Whilst attempting to deploy a Test Stand system I am coming across the following error:
Error: Unable to find all subVIs from saved VIs. Either a subVI is missing or the VI is not saved in the current LabVIEW version.
The call chain to missing VIs:
1 - initialise_resistor_card.vi
    2 - pipx40 Initialize.vi (missing)
I have the Teststand Adaptor set to Labview Run-time Engine --> "Auto detect using VI version"
This is a new feature in Test Stand 2010 right? So is the deployment tool also able to inherit the ability to auto detect the version of runtime engine to use on a deployed machine?  
Any ideas?
Regards
There is no problem with the VI within the sequence.
I've encountered this before before with the deployment tool and usually mass compilling or opening and closing the VIs heirarchy helps, but in this case I just can't get the deployemnt tool to process these VIs.

Hello,
So it would appear that the VIs giving the problem are within .llb . 
If I open and save them again within the .llb and mass compile the .llb then the same happens, but if I take the VI out of the llb then the problem goes away?
Is there any known issues with the Deployment Utility failing to find VIs with llbs? I notice TS 2010 deployment utility introduces the idea of a Packed Project library option rather than the old SupportVIs folder, could using this be the issue?
Regards
Matt

Similar Messages

  • Deployment Tool Error - unknown document type - Add to Application EJB jar

    I am creating a new application in the J2EE deployment tool and adding an EJB JAR to it. The jar contains the ejb-jar.xml file. This file has the standard doctype:
    <!DOCTYPE ejb-jar PUBLIC
    '-//Sun Microsystems, INC.//DTD Enterprise JavaBeans 1.1//EN'
    'file:/C:/j2sdkee1.3/lib/dtds/ejb-jar_2_0.dtd'>
    I get the Unknown Document Type error when I try to add this jar to the application:
    Error: Adding EJB JAR - java.lang.RuntimeException: Invalid XML : Unknown document type : org.apache.crimson.tree.Doctype@e8647
    The xml file validates fine in NetBeans 3.4. I use NetBeans to generate the jar file.
    Any ideas as to what is happening would be appreciated.

    Try replacing the DTD definition as specified below.
    http://java.sun.com/dtd/ejb-jar_2_0.dtd
    regards,
    Siddique

  • How To Trigger Test Stand To Assign Step = Error

    Hi everyone, I have a LabVIEW VI step in my sequence and I have an abort button the user can select to abort the user interface VI.  I want the "abort button" boolean to pass back to test stand that abort button = TRUE and I want the sequence step to be set to an "ERROR."  Is there a command to send to the Test Stand Engine to flag this step as an error?
    Thanks so much!
    Solved!
    Go to Solution.

    Hi
    Glad It was helpful.
    There are two ways in which you could achive this..
    1. Use this expression: RunState.Engine.TerminateAll()
    But be wary, this will terminate all the current excutions and the report indicates the status as "terminated"
    or
    2. Use this expression: RunState.Execution.Terminate()
    or
    3. You can add a Goto step (comes with teststand. You can find it under Flow Control section of the insertion palette) and select Cleanup as the destination step.
    This way you can run some clean up steps before closing the execution. (eg, Shutting down any hardware, etc.,)
    Deepak

  • How can I pass a variable from Test Stand to CVI by reference

    Hi!
    I can't to pass numeric or boolean variable from Test Stand (for example: FileGlobals.StopFlag) into the step (CVI function).
    Function prototype: 
    void __declspec(dllexport) __cdecl PC2_WaitWhileResponceAppear(tTestData *testData, tTestError *testError, int *iStopFlag).
    When variable has bin changed I can't see this change from my function.
    CVI 2010, Test Stand 2010
    Can anybody help me?

    Hey Rombar,
    It is certainly possible to pass variables by reference; for example, if you go to <TestStand Directory>/Examples/Demo/C and open the computer.seq file, you can see one of the example sequences that uses CVI modules. If you click on one of these steps, you'll see that some of the parameters, such as the error information, is passed with pointers. This is a pass by reference.
    To help narrow this down, it'd be good for us to figure out a few things about how the code is run. First, if you go to Configure > Adapters, select the CVI adapter and choose Configure, you can see options for this adapter. Do you have it configured to run in an external instance of CVI or as an in-process call?
    Also, if you're wanting to see a change made in TestStand in your external code, this makes me think that you're wanting to run the code and then continue to execute your TestStand sequence while the code runs. How did you configure this behavior? For example, are you calling this code as a separate sequence in a new thread, or are you using another method to run this code while the sequence continues to run?
    Finally, if we could see a screenshot of how you're configuring the parameters on the TestStand step, that might be helpful as well.
    Daniel E.
    TestStand Product Support Engineer
    National Instruments

  • Can labview call a test stand module

    Having problems with a test dll that runs in test stand, but I get errors when trying to use the wizard in labview, however I can use the call library function node to protypye it.  Problem - the function openComserialPort(char* comPort, ErrStruct & err), how do you difine the parameters for the ErrStruct & err part.
    next Question, since this Dll runs in Test Stand, is their anyway to export to work in LabVIEW. 
    Solved!
    Go to Solution.

    Here's a description of the dll, to start off, I have a circuit board with a microprocessor on it, that has control for a radio module.  During test I need to program this board serially through its' TX and RX lines on the processor.  The dll given to me, which was written for test stand, has functions to enable me to do this programming.  There are basically  11 function contained is this Dll. 
    Initialize Dll, (no errors),
    open serial port, (no errors), 
    getStandardTable, which sends a command for the microprocessor to send back its information-> get assertion error
    WriteHardwareVersion -> Sends the version and revision number -> assertion error.
    ColdStart -> Which resets board statistics variables -> assertion error.  Now, this function prototype is ColdStart (errStruct & err); So I prototype like I did for the above error struct, but still got an assertion error, which leaves me to believe, that , or vendor, has a bug communicating, or sending the commands via serially, to test this, I could use the serial examples contained in LabVIEW, however I don't know the command set of the microprocessor, or could there be something else wrong,  Any ideas will be appreciated.

  • Test Stand Deployment; Internal Error Code 1

    Hi,
    I get the following message from the deploymeny tool when trying to deploy my system...
    Internal error code 1 Processing VIs...
    An installer was not created due to an error
    I have mass compiled everything and all the VIs are working, my workspace processes okay and the sequences run okay in the Run time Engine adaptor of Test Stand.
    Any ideas what could be causing this? I have Test Stand 4.0.0 and labview 8.5.
    Many thanks
    Matt

    Hi Rick, see below cut and paste from this file, does this help?
    08:55:43tarting Log.
    08:55:45tarting Analysis
    08:55:45tarting to process workspace file
    08:55:56one processing workspace file
    08:55:56:Finished Analysis
    08:55:57:Building...
    08:55
    08:57:01:Internal error code 1 Processing VIs...
    08:57:01:Could not process LabVIEW VIs. Fix any broken VIs before rebuilding. LabVIEW error:
    Error copying files.
    Source:
    Destination: <Not A Path>
    Librarian Path Location.vi
    <Call Chain>Error 1 occurred at ABAPI Dist Copy Non-VI Files.vi -> ABAPI Dist Build LLB Image.vi -> ABAPI Copy Files and Apply Settings.vi -> TestStand - Build VI Distribution 8 AX Wrapper.vi -> TestStand - Build VI Distribution 8 AX Wrapper.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  An input parameter is invalid. For example if the input is a path, the path might contain a character not allowed by the OS such as ? or @.
    =========================
    NI-488:  Command requires GPIB Controller to be Controller-In-Charge.
    08:57:01:An installer was not created due to an error
    08:57:01:The build is finished
    08:57
    08:57:01:Aborted
    08:57:01:---------------------------------------
    Many Thanks
    Matt

  • Deployment teststand error (labview test - sequence context)

    Hello,
    I need help by deploying my workspace to the deployment(target)computer. That is what I have done:
    - i create a workspace, in this workspace are different sequence files and the vi´s which i have created.
    - then i use the deployment tool (teststand) and deploy the workspace to a directory in the network.
    - after that i copy the modified SequentialModel.seq to the target maschine.
    - now if i want start the sequence file an error occured. Teststand can`t start my vi´s because it can`t find files like LabVIEW Test - Sequence Context, TestStand - Set Property Value (Boolean Array). Choosing the path of the file in the search directory doesn`t help.
    Maybe i have made an error with the deployment tool?! How is the right way to deploy in a network without using an installer. Iám using teststand 3.0.
    thankyou
    Schwede

    Hi Schwede
    If you want to deploy your Sequence File and the Processmodell you have to copy first your original Processmodell from the NI folder to the user folder.
    Than open the deploy-tool and load your workspacefile. Mark the point "deploy files in Teststand user directories" and define the image path. Don't mark the "create installer" field.
    You will get and image folder with several subfolder.
    In the target subfolder you can find your sequencefile. In the Teststand subfolder you can find your customized Processmodell or Operator Interfaces. Attention, please use relative paths when you create your workspacefile.
    hope this helps
    Manuel Wielander
    National Instruments

  • Office 2013 deployment tool Invalid product ID error

    Hi,
    Im in the process of virtualizing apps like Office 2013 with App-V. 
    Downloading the binaries with the Office Deployment tool and converting to app-v package is very easy, I've followed this kb
    http://support.microsoft.com/kb/2915745
    But now I want to sequence add-ins for Office 2013. So I need a local install of Office 2013 click to run.
    Im trying to use the command line option setup.exe /configure <path to config.xml> but everytime I try this I receive this error:
    Invalid product ProPlusVolume specified. Error configuring products
    I have tried several different ProductID's like ProPlusVolume and StandardVolume. None of the volume ID's seem to work. When I changed the ID to ProPlusRetail, the setup worked flawless. But I need to install the Volume version for my RDS server...
    I have found other people in the comment section in this blog: http://blogs.technet.com/b/office_resource_kit/archive/2013/12/03/3615124.aspx
    (read the comments in the bottom section) But no solution..?

    It's my understanding that  you don't use the "/configure" parameter when using the "Volume" options.
    Jeremy refers to this in the comments/responses.
    In the main blog article, he refers to "You can now use the Deployment Configuration file to configure...."
    This does not mean that you should use the "/configure" parameter - that is only used for C2R.
    Don
    (Please take a moment to "Vote as Helpful" and/or "Mark as Answer", where applicable.
    This helps the community, keeps the forums tidy, and recognises useful contributions. Thanks!)

  • Error starting the Application Server and Deployment Tool

    After installing the iPlanet Aplication Server with sp3 I get the following
    errors starting the Application Server and Deployment Tool.
    iAS Application Server
    ================
    GXBindInit: GXBindBasic failed
    GXContextInit: GXBindInit failed 2
    [26/Out/2001 17:46:49:8] error: ENGINE-context_init_failed: EngineClassSpace
    ContextModule.createContextInit failed:
    error: could not get context
    *** Errors in initialization from registry ***
    Errors in initialization, exiting ...
    iAS Deployment Tool
    ===============
    GXBindInit: GXBindBasic failed
    GXContextInit: GXBindInit failed 2
    [26/Out/2001 17:23:40:7] error: ENGINE-context_init_failed: EngineClassSpace
    ContextModule.createContextInit failed:
    Exception in thread "main" java.lang.NullPointerException
    at com.kivasoft.util.Util.loadComponent(Unknown Source)
    at
    com.iplanet.ias.tools.buzz.ui.application.StartBuzz.initGDS(Unknown Source)
    at com.iplanet.ias.tools.buzz.ui.application.StartBuzz.main(Unknown
    Source)
    Can anyone help me please!

    Hi,
    Would be more helpful if you can mention, the O/S. Also, pls mention where
    you are getting this error, at kjs or kxs, or, are you able to start the server
    and at which specific instance do you encounter this.
    Regards
    Raj
    "Antonio Casqueiro" wrote:
    After installing the iPlanet Aplication Server with sp3 I get the following
    errors starting the Application Server and Deployment Tool.
    iAS Application Server
    ================
    GXBindInit: GXBindBasic failed
    GXContextInit: GXBindInit failed 2
    [26/Out/2001 17:46:49:8] error: ENGINE-context_init_failed: EngineClassSpace
    ContextModule.createContextInit failed:
    error: could not get context
    *** Errors in initialization from registry ***
    Errors in initialization, exiting ...
    iAS Deployment Tool
    ===============
    GXBindInit: GXBindBasic failed
    GXContextInit: GXBindInit failed 2
    [26/Out/2001 17:23:40:7] error: ENGINE-context_init_failed: EngineClassSpace
    ContextModule.createContextInit failed:
    Exception in thread "main" java.lang.NullPointerException
    at com.kivasoft.util.Util.loadComponent(Unknown Source)
    at
    com.iplanet.ias.tools.buzz.ui.application.StartBuzz.initGDS(Unknown Source)
    at com.iplanet.ias.tools.buzz.ui.application.StartBuzz.main(Unknown
    Source)
    Can anyone help me please!

  • Error starting the Application Server and Deployment Tool in Windows 2000

    After installing the iPlanet Aplication Server with sp3 in Windows 2000 I
    get the following
    errors starting the Application Server and Deployment Tool.
    iAS Application Server
    ================
    GXBindInit: GXBindBasic failed
    GXContextInit: GXBindInit failed 2
    [26/Out/2001 17:46:49:8] error: ENGINE-context_init_failed: EngineClassSpace
    ContextModule.createContextInit failed:
    error: could not get context
    *** Errors in initialization from registry ***
    Errors in initialization, exiting ...
    iAS Deployment Tool
    ===============
    GXBindInit: GXBindBasic failed
    GXContextInit: GXBindInit failed 2
    [26/Out/2001 17:23:40:7] error: ENGINE-context_init_failed: EngineClassSpace
    ContextModule.createContextInit failed:
    Exception in thread "main" java.lang.NullPointerException
    at com.kivasoft.util.Util.loadComponent(Unknown Source)
    at
    com.iplanet.ias.tools.buzz.ui.application.StartBuzz.initGDS(Unknown Source)
    at com.iplanet.ias.tools.buzz.ui.application.StartBuzz.main(Unknown
    Source)
    Can anyone help me please!

    Okay, pls check that you are logged in as administrator and installed and now you are logged in as administrator and registering the iAS server. Did you get any installation failures while installing and are you able to register the server using iASAT ?

  • Error installing 365 Pro Plus from deployment tool

    I have 1 Windows 7 x64 PC which is failing to install from the deployment tool. It is built from the same image as 50-60 other PCs which had no issues installing using the same XML configuration file and network share. The log always shows the same few lines
    at the end implying there is some kind of pre-requisite missing. So far I have tried:
    Scanned for Windows updates and installed all available
    Ran the Fix It tool from KB 2739501 which said it could not detect any problems
    Checked that the registry entries did not exist for HKLM\Software\Microsoft\Office\15.0 and HKCU\Software\Microsoft\Office\15.0
    Checked "C:\Program files\Microsoft Office 15" does not exist
    Checked "C:\Program files (x86)\Microsoft Office 15" does not exist
    Tried creating a new local administrator account
    Uninstalled the previous version of Office
    The last few lines of the log are:
    04/08/2014 17:08:12.366 SETUP (0x8e4) 0x508  Click-To-Run anhmn Unexpected Prereq::PrereqsFailed: OException has occured ErrorCodeOnly (failed MsiEnumProducts , Error:0x64a). Exiting bootstrapper. 
    04/08/2014 17:08:12.366 SETUP (0x8e4) 0x508  Click-To-Run aoh88 Medium RunPrereqs::HandleStateAction Prereq check has failed. 
    04/08/2014 17:08:12.366 SETUP (0x8e4) 0x508  Click-To-Run aoh9e Unexpected HandlePrereqFailure::HandleStateAction: Failure has occured with unknown action: 160 
    04/08/2014 17:08:12.366 SETUP (0x8e4) 0x508  Click-To-Run aoh71 Medium BootstrapperState::OnError: Error has occured. Go to ExitBootStateMachine. 
    04/08/2014 17:08:12.366 SETUP (0x8e4) 0x508  Click-To-Run aoh9f Medium BootStateMachine::ShowFailureUI: Showing failure UI. 

    04/08/2014 17:08:12.366 SETUP (0x8e4) 0x508  Click-To-Run anhmn Unexpected Prereq::PrereqsFailed: OException has occured ErrorCodeOnly (failed MsiEnumProducts , Error:0x64a).
    0x64a = 1610 (hex-to-decimal)
    MSI error reference:
    ERROR_BAD_CONFIGURATION
    1610
    The configuration data for this product is corrupt. Contact your support personnel.
    -=-=-
    Not terribly helpful. Are there other errors in the event log of the machine (maybe bad hardware or other issues)?
    Don
    (Please take a moment to "Vote as Helpful" and/or "Mark as Answer", where applicable.
    This helps the community, keeps the forums tidy, and recognises useful contributions. Thanks!)

  • Error when closing test stand

    when i try to close test stand after i run a test, i got the error in the
    attached file.
    this error appear only if i dont close the sequence file before i exit test
    stand and only after i run a test.
    please help me.
    advanced thank's.
    [Attachment error.jpg, see below]
    [See first answer for additional information]

    Hello Avi,
    The error is caused by TestStand not being able to finish the LoginLogout sequence before its time limit. These limits are set under Configure >> Station Options >> Time Limits. They will allow you to interrupt a sequence that is taking too long to shut down.
    The real problem may be in the LoginLogout sequence, in the file \Components\User\Callbacks\FrontEnd\FrontEndCallbacks.seq (or substitute "NI" for "User" in the path). If something in that sequence doesn't finish executing within 10 seconds, due to an extreme slowdown or a problem with the sequence, you will see this error. If you have modified that sequence, this could be the cause. You will need at least two steps in the sequence, one for Login and another for Logout. They should
    reference frontend.dll. If you have a modified callback in your User directory, trying copying the default callback from the NI directory.
    Also, make sure that you complete or terminate other sequences before trying to close TestStand, or you will see a similar error message.
    Good luck and feel free to ask if you have further questions.
    Steven Reasoner
    Applications Engineering
    National Instruments

  • Error when trying to install MS Exchange 2010 Management Tools Windows 7 x64 SP1

    When I try to install Exchange 2010 Management Tools on my Windows 7 Pro x64. I get the message ExSetupUI.exe has stopped working? Has anybody else gotten this message?  It doesn't even load into the install screen. It is stopping before then.

    Hi
    Have you installed the admin tools for windows 7 and all the prerequisites? Try running the setup from an elevated prompt or "as Administrator"
    for ref:
    http://social.technet.microsoft.com/Forums/en-US/63880f4e-6b6e-4ea9-b3b6-8a535657288f/installing-exchange-management-tools-on-a-win-7-x64-box-getting-error-on-readiness-checks?forum=exchange2010

  • Error in Office Deployment tool

    hi,
    Error in Office Deployment tool
    Any known issue?  tnx

    I've seem the same problem twice today. Check your local network status and disable filewall/AVG to try it again.
    You may also refer to the answer in my another threads and let me know your update. Thanks.
    http://social.technet.microsoft.com/Forums/en-US/de716bad-ad39-4dc6-a473-c43574afd942/office-deployment-tool-fails-to-download-source-files?forum=offi 
    Tony Chen
    TechNet Community Support

  • Windows Network Drive Mapping properties not being associated with Test Stand deployment

    I recently upgraded a TestStand/LabVIEW (Developer Suite 2012 DS1) deployment project from a Windows XP Pro OS to Windows 7 Enterprise. Now, when I run the Test Stand deployment, Network paths that used to be hard coded into my File Globals are no longer recognized. I re-wrote the vi's, and put "File Dialog" pop-ups so that I could see what path the control is being opened up at, and what appears to be happening is the Network Drive that I am defaulted to is appearing as if it is "disconnected" in the navigation window, and the path is defaulted to my root directory. I can navigate out to my network path no problem from the navigation window, and after the first time I perform this user action, subsequent executions open up to the path I have hard coded in my Sequence File Globals. However, if I reboot my host computer, I again have to go through the exercise of manually pointing to the proper network location? If I use the Windows Explorer to check Mapped Networked Drives, everything is properly mapped and connected.
    Has anyone ever seen this behavior? 

    Hi ATE Dude 22,
    I have not come across this problem before but here is a document from MSDN and one from NI which discuss file path conventions. From what I've seen, UNC is also accepted under Windows XP so I would advise using it for your file globals.
    Cheers,
    KyleP
    Applications Engineer
    National Instruments

Maybe you are looking for