I'm receiving the following errors on all SQL Express Servers (every machine that has SQL Express inside).
it seems that the discovery has found SQL Express but could not connect to the instance.
details on the alerts:
Date and Time:
10/22/2013 12:04:22 PM
Log Name:
Operations Manager
Source:
Health Service Modules
Generating Rule:
Collect Power Shell Module Events
Event Number:
22406
Level:
 Error
Logging Computer:
SQLEXPRESS.DOMAIN.COM
User:
N/A
Description:
The PowerShell script failed with below exception
System.Management.Automation.RuntimeException: Exception calling "Fill" with "1" argument(s): "A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not
accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified)"
At line:44 char:19
+ $SqlAdapter.Fill <<<< ($DataSet)|out-null
at System.Management.Automation.FlowControlNode.Execute(Array input, Pipe outputPipe, ExecutionContext context)
at System.Management.Automation.ParseTreeNode.Execute(Array input, Pipe outputPipe, ArrayList& resultList, ExecutionContext context)
at System.Management.Automation.StatementListNode.ExecuteStatement(ParseTreeNode statement, Array input, Pipe outputPipe, ArrayList& resultList, ExecutionContext context)
Script Name: StolenServerMemory2008.ps1
One or more workflows were affected by this.
Workflow name: Microsoft.SQLServer.2008.DBEngine.StolenServerMemoryMonitor
Instance name: SQLEXPRESS
Instance ID: {9705795C-4F3B-C2EF-AA7D-C736B40FD6A4}
Management group: SCOMGROUP 

Some additional inf.
http://stackoverflow.com/questions/6466974/unable-to-connect-to-sql-express-error-26-error-locating-server-instance-speci?rq=1
anyway you can disable this rule/monitor as no control from monitoring solution in that case. Or try to rewrite the same monitor...
The problem in your case is when function tries to get Max Server Memory MB by connecting to master DB, but you can replace it with performance counter like Target Server Memory (KB)...
just see the function main in StolenServerMemory2008.ps1 and what you need to replace
$api = New-Object -comObject "MOM.ScriptAPI"
$bag = $api.CreatePropertyBag()
$msg = [Environment]::NewLine
$err = [Environment]::NewLine
#try {
$maxMemoryMB = GetMaxServerMemoryMB $ComputerName $InstanceName
$stolenPages = (Get-Counter ("\" + $PerformanceCounterObject + ":Buffer Manager\Stolen Pages")).CounterSamples[0].CookedValue
$pakeSizeKB = 8
[double]$stolenMemoryMB = $stolenPages * $pakeSizeKB / 1024                                      
[double]$stolenMemoryPercent = 0
if($maxMemoryMB -gt 0){
[double]$stolenMemoryPercent= 100.0 * $stolenMemoryMB / $maxMemoryMB
$bag.AddValue("StolenMemoryMB", $stolenMemoryMB)
$bag.AddValue("StolenMemoryPercent", $stolenMemoryPercent)                                  
$msg += "StolenMemoryMB=$stolenMemoryMB StolenMemoryPercent=$stolenMemoryPercent"
$msg += [Environment]::NewLine                          
#debug $api.LogScriptEvent("SQL 2008 Stolen Server Memory data source", $SCRIPT_EVENT_ID, $INFORMATION_EVENT_TYPE, $msg + $err)                     
#catch {
#             $header = "Managegement Group: $Target/ManagementGroup/Name$. Script: {0}" -f ($MyInvocation.MyCommand).Name.ToString()
#             $msg += "Error occured during SQL 2008 Stolen Server Memory data source executing.{0}Computer:{1} {0}Reason: {2}" -f [Environment]::NewLine, $env:COMPUTERNAME, $_.Exception.Message
#             $api.LogScriptEvent($header, $SCRIPT_EVENT_ID, $ERROR_EVENT_TYPE, $msg + $err)                           
$bag

Similar Messages

  • SSIS 2012 is intermittently failing with below "Invalid date format" while importing data from a source table into a Destination table with same exact schema.

    We migrated Packages from SSIS 2008 to 2012. The Package is working fine in all the environments except in one of our environment.
    SSIS 2012 is intermittently failing with below error while importing data from a source table into a Destination table with same exact schema.
    Error: 2014-01-28 15:52:05.19
       Code: 0x80004005
       Source: xxxxxxxx SSIS.Pipeline
       Description: Unspecified error
    End Error
    Error: 2014-01-28 15:52:05.19
       Code: 0xC0202009
       Source: Process xxxxxx Load TableName [48]
       Description: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x80004005.
    An OLE DB record is available.  Source: "Microsoft SQL Server Native Client 11.0"  Hresult: 0x80004005  Description: "Invalid date format".
    End Error
    Error: 2014-01-28 15:52:05.19
       Code: 0xC020901C
       Source: Process xxxxxxxx Load TableName [48]
       Description: There was an error with Load TableName.Inputs[OLE DB Destination Input].Columns[Updated] on Load TableName.Inputs[OLE DB Destination Input]. The column status returned was: "Conversion failed because the data value overflowed
    the specified type.".
    End Error
    But when we reorder the column in "Updated" in Destination table, the package is importing data successfully.
    This looks like bug to me, Any suggestion?

    Hi Mohideen,
    Based on my research, the issue might be related to one of the following factors:
    Memory pressure. Check there is a memory challenge when the issue occurs. In addition, if the package runs in 32-bit runtime on the specific server, use the 64-bit runtime instead.
    A known issue with SQL Native Client. As a workaround, use .NET data provider instead of SNAC.
    Hope this helps.
    Regards,
    Mike Yin
    If you have any feedback on our support, please click
    here
    Mike Yin
    TechNet Community Support

  • ERROR - the ProtectKeyWithTPMAndPIN Method failed with the exit code: 8031005B

    Hello
    I am using the EnableBitlocker.vbs script to automatically assign the TPM and start the encryption. I am running it from an elevated command prompt. Here is are the arguments I am running with
    cscript EnableBitLocker.vbs /on:tp
    /l:c:\bitlockerlog.log /promptuser /ro:"MBAM" on
    All is well and it prompts the user for a PIN but then it fails.
    Here is the full log file. I haven't been able to find any info on the error code in the subject.
    Script processing started  02/07/2014       14:43:27
    Proper number of command line arguments passed to the script
    ---------------Executing with the following arguments------------------
    Enable parameters: tp
    Logging location: c:\bitlockerlog.log
    Create recovery key: No recovery key use specified
    Encryption method: 3
    Create SMS status MIF's: No SMS status MIF's will be created
    Reset TPM ownership: 1
    User prompting: 1
    Connection succeeded to MicrosoftTPM
    Successfully retrieved a TPM instance from the Win32_TPM provider class
    TPM found in the following state:
    Enabled - True
    Activated - True
    Owned - True
    Connection succeeded to MicrosoftVolumeEncryption
    TPM is in a ready state to enable BitLocker.
    Change TPM owner password specified on the command line.
    Random TPM owner password is: ;&K:)BU65|c7_v2n
    Completed converting old owner password to owner authorization:  0
    Completed converting owner password to owner authorization:  0
    Starting to change owner authorization process on the TPM
    ERROR - Failed to change owner authorization on the TPM with the following exit code:  80280001
    Successfully connected to WMI StdRegProv
    Checking if Group Policy encryption method is set...
    Found EncryptionMethod with value: 4
    Found EncryptionMethod policy registry key ignoring any /em options on command line
    Found ActiveDirectoryBackup with value: 1
    Found RequireActiveDirectoryBackup with value: 1
    Determined client Group Policy configured to require AD escrow of recovery password
    EncryptableVolumes count is: 1
    The EncryptableVolume(s) found: \\?\Volume{ad6db324-01dd-11e4-8272-806e6f6e6963}\
    EncryptableVolume used for encryption is: C:
    The volume has a protection status of: 0
    BitLocker Protection is Off
    Get conversion status is: 0
    The volume has a status of fully decrypted
    The following user is logged on: MGMT\80151318-sys
    Attempting to enable BitLocker TPM + Pin
    ERROR - the ProtectKeyWithTPMAndPIN Method failed with the exit code:  8031005B
    Script ended  02/07/2014       14:43:51
    Any and all help would be appreciated. This has worked before on a different laptop.
    Thanks

    Hi,
    This error indicates that the group policy isn't set correctly, when configure the group policy at teh server side, you should notice that only one of the additional authentication can be required at start up , otherwise a policy occurs, the notice can be
    found just like below:
    and after test, the error indeed occurs, just like the screen below:
    So, I suggest to check the group policy for bitlocker settings, you can only choose one start up authentication method.
    Regards
    Wade Liu
    TechNet Community Support

  • An unknown error occurred while executing the PowerShell script:

    Hello all,
    Not the most descriptive title, granted. I'm hoping this may prompt the next version toprovide additional valuable content.
    Kindly requesting any help on this problem. I'm running VMM 2012 R2 version 3.2.7668
    When I try to look at properties of an existing Private Cloud, I get this error, only if I "look" at certain attributes. If I stay away from the specific attributes, everything is hunky dory. For reasons unknown, after I get this error, I have
    to exit and go back into VMM in order to get anything else to run.
    The text in the error dialogue box is not entirely applicable because I was connected to the VMM server and will connect again, when I exit/relaunch.
    An unknown error occurred while executing the PowerShell script:
    The connection to the VMM management server scvmm2.mmmmmm.com was lost.
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Try the operation again. If the issue persists, contact Microsoft Help and Support.
    ID: 27235
    This is what I get in Events
    Warning 4/9/2015 3:27:04 PM PowerShell (Microsoft-Windows-PowerShell) 4100 Executing Pipeline
    Log Name:      Microsoft-Windows-PowerShell/Operational
    Source:        Microsoft-Windows-PowerShell
    Date:          4/9/2015 3:27:04 PM
    Event ID:      4100
    Task Category: Executing Pipeline
    Level:         Warning
    Keywords:      None
    User:          mmmmmm\paufra
    Computer:      tools-francis.mmmmmm.com
    Description:
    Error Message = The connection to the VMM management server scvmm2.mmmmmm.com was lost. (Error ID: 1610)
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Fully Qualified Error ID = 1610,Microsoft.SystemCenter.VirtualMachineManager.Cmdlets.GetSCReplicationGroupCmdlet
    Recommended Action = Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager
    service is started on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Context:
            Severity = Warning
            Host Name = Default Host
            Host Version = 4.0
            Host ID = 94963cd4-5979-4786-9da2-c8814de8c7c3
            Host Application = C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine Manager\Bin\VmmAdminUI.exe
            Engine Version = 4.0
            Runspace ID = 359d7a46-3752-4929-8c09-0de4152d10e4
            Pipeline ID = 16
            Command Name = Get-SCReplicationGroup
            Command Type = Cmdlet
            Script Name =
            Command Path =
            Sequence Number = 91
            User = mmmmmm\paufra
            Shell ID = Microsoft.PowerShell
    User Data:
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-Windows-PowerShell" Guid="{A0C1853B-5C40-4B15-8766-3CF1C58F985A}" />
        <EventID>4100</EventID>
        <Version>1</Version>
        <Level>3</Level>
        <Task>106</Task>
        <Opcode>19</Opcode>
        <Keywords>0x0</Keywords>
        <TimeCreated SystemTime="2015-04-09T22:27:04.993655700Z" />
        <EventRecordID>285</EventRecordID>
        <Correlation ActivityID="{48059811-1A63-41E1-9057-7498D0E4FC20}" />
        <Execution ProcessID="2344" ThreadID="4076" />
        <Channel>Microsoft-Windows-PowerShell/Operational</Channel>
        <Computer>tools-francis.mmmmmm.com</Computer>
        <Security UserID="S-1-5-21-4008432563-1984933819-4238309236-2721" />
      </System>
      <EventData>
        <Data Name="ContextInfo">        Severity = Warning
            Host Name = Default Host
            Host Version = 4.0
            Host ID = 94963cd4-5979-4786-9da2-c8814de8c7c3
            Host Application = C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine Manager\Bin\VmmAdminUI.exe
            Engine Version = 4.0
            Runspace ID = 359d7a46-3752-4929-8c09-0de4152d10e4
            Pipeline ID = 16
            Command Name = Get-SCReplicationGroup
            Command Type = Cmdlet
            Script Name =
            Command Path =
            Sequence Number = 91
            User = mmmmmm\paufra
            Shell ID = Microsoft.PowerShell
    </Data>
        <Data Name="UserData">
        </Data>
        <Data Name="Payload">Error Message = The connection to the VMM management server scvmm2.mmmmmm.com was lost. (Error ID: 1610)
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Fully Qualified Error ID = 1610,Microsoft.SystemCenter.VirtualMachineManager.Cmdlets.GetSCReplicationGroupCmdlet
    Recommended Action = Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager
    service is started on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    </Data>
      </EventData>
    </Event>

    Hi Sir,
    First , please try to run the VMM configuration analyzer on that computer :
    http://www.microsoft.com/en-us/download/details.aspx?id=41555
    In addition , please try to use "VMMTrace" mentioned in following article to collect trace log and find some useful information :
    http://blogs.technet.com/b/jonjor/archive/2011/01/07/vmmtrace-simplified-scvmm-tracing.aspx
    Best Regards,
    Elton Ji
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • ARV_BC_XMB_DEL Fails With Raise Exception

    Hi All,
        I have scheduled the archiving job in PI 7.0 through sxmb_adm -> Schedule Archiving.
        After scheduling I can see two jobs successfully released
                1. ARV_BC_XMB_DEL - This job uses the program "RSXMB_DELETE_ARCHIVED_MESSAGES"
                2. ARV_BC_XMB_WRP - This uses the program "RSXMB_ARCHIVE_MESSAGES"
        The second job (which is archiving of xml messages) is running good but the First Job "ARV_BC_XMB_DEL" fails with a
        "ABAP/4 processor: RAISE_EXCEPTION."
       Both the jobs are running fine on DEV & QA systems.
       But the first job fails on Pre-Prod & Prd (which are high available systems).
       Any hints/help on why its failing with an exception on Pre-PRD & PRD ?
    <removed by moderator>
    Thanks
    Sourav
    Edited by: Mike Pokraka on Jul 24, 2008 12:52 PM

    Yes. This is what it says.
    Short text
        Exception condition "NO_DDIC_TYPE" raised.
    What happened?
        The current ABAP/4 program encountered an unexpected
        situation.
    What can you do?
        Note down which actions and inputs caused the error.
        To process the problem further, contact you SAP system
        administrator.
        Using Transaction ST22 for ABAP Dump Analysis, you can look
        at and manage termination messages, and you can also
        keep them for a long time.
    Error analysis
        A RAISE statement in the program "CL_ABAP_TYPEDESCR=============CP" raised the
         exception
        condition "NO_DDIC_TYPE".
        Since the exception was not intercepted by a superior
        program, processing was terminated.
        Short description of exception condition:
        For detailed documentation of the exception condition, use
        Transaction SE37 (Function Library). You can take the called
        function module from the display of active calls.
    How to correct the error
        If the error occures in a non-modified SAP program, you may be able to
        find an interim solution in an SAP Note.
        If you have access to SAP Notes, carry out a search with the following
        keywords:
        "RAISE_EXCEPTION" " "
        "CL_ABAP_TYPEDESCR=============CP" or "CL_ABAP_TYPEDESCR=============CM00C"
        "GET_DDIC_HEADER"
        or
        "CL_ABAP_TYPEDESCR=============CP" "NO_DDIC_TYPE"
        or
        "RSXMB_DELETE_ARCHIVED_MESSAGES " "NO_DDIC_TYPE"
        If you cannot solve the problem yourself and want to send an error
        notification to SAP, include the following information:
        1. The description of the current problem (short dump)
           To save the description, choose "System->List->Save->Local File
        (Unconverted)".
        2. Corresponding system log
           Display the system log by calling transaction SM21.
           Restrict the time interval to 10 minutes before and five minutes
        after the short dump. Then choose "System->List->Save->Local File
        (Unconverted)".
        3. If the problem occurs in a problem of your own or a modified SAP
        program: The source code of the program
           In the editor, choose "Utilities->More
        Utilities->Upload/Download->Download".
        4. Details about the conditions under which the error occurred or which
        actions and input led to the error.

  • Indexing Lotus Repository fails with an exception

    Hi,
    I am trying to index a lotus repository. But after indexing around 10000 documents the indexing fails with an exception.
    "Crawler global_index_Telstra Technology Doc Library failed - com.sapportals.wcm.service.xcrawler.XCrawlerException: crawler task INDEXMANAGEMENT_global_index.409bc343-1a86-2710-0292-b5747d8b1241 terminated unexpectedly (retriever failure)"
    Does anyone have an idea why its happening like this
    Its a bit urgent
    Regards
    Prakash

    Hi Prakash,
    assuming your intrante sites are crawled by a crawler profile "for Web-RM" the most common things you may still need to do are:
    - In the crawler parameters, Mark "Follow Links (or Redirects on Web-Sites)", if your start page(s)
    - On the intranet sites, check if they use robot information that says "noindex" or "nofollow" and possibly change that
    If that does not help...sorry, it's OSS again.
    Karsten

  • Troubleshooting PostPrepare script failed with exit code 1

    i get a 'PostPrepare' script failed with exit code '1' message on one of the bundles, and i think i am missing some obvious thing
    it is a simple file bundle, to distribute a pdf printer:
    it distributes 2 files:
    ADIST.PPD to /usr/share/cups/model
    pdf-printer to /usr/lib/cups/backend
    (script based upon Cool Solutions: A CUPS PDF Printer for your SUSE Linux Enterprise Desktop
    then it should execute a pre-installation script that executes:
    Code:
    #!/bin/bash
    rccups restart
    mkdir -p /export/share/pdf
    chmod -R 777 /export
    lpadmin -p Desktop-PDF -v pdf-writer:/export/share/pdf/ -E -P /usr/share/cups/model/ADIST5.PPD -D "PDF Writer for CUPS" -L "PDF on desktop"
    manually placing the files on these locations and executing the script works fine
    on the machine i get (device set to log debug and above)
    Code:
    22 Jul 2010 09:33:00 INFO BundleManager Executing preprepare scripts for PDF printer
    22 Jul 2010 09:33:00 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:00 INFO WebCache Attempting to retrieve 'https://zlmserver/zenworks-pkgmgt/repo/getBundleFile/3ba56c5bc95bb2874273a7d0cae07d14/8/sled-11-i586/ADIST5.PPD' (try 1)
    22 Jul 2010 09:33:01 INFO WebCache Successfully retrieved https://zlmserver/zenworks-pkgmgt/repo/getBundleFile/3ba56c5bc95bb2874273a7d0cae07d14/8/sled-11-i586/ADIST5.PPD
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 INFO WebCache Attempting to retrieve 'https://zlmserver/zenworks-pkgmgt/repo/getBundleFile/3ba56c5bc95bb2874273a7d0cae07d14/8/sled-11-i586/pdf-writer' (try 1)
    22 Jul 2010 09:33:01 INFO WebCache Successfully retrieved https://zlmserver/zenworks-pkgmgt/repo/getBundleFile/3ba56c5bc95bb2874273a7d0cae07d14/8/sled-11-i586/pdf-writer
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 INFO BundleManager Executing postprepare scripts for PDF printer
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 INFO BundleManager Successfully prepared bundles
    22 Jul 2010 09:33:01 INFO BundleManager Beginning bundle transaction
    22 Jul 2010 09:33:01 INFO BundleTransaction Beginning bundle transaction: 1 installs, 0 removals.
    22 Jul 2010 09:33:01 INFO BundleTransaction Executing preinstall scripts for PDF printer
    22 Jul 2010 09:33:01 INFO SystemCatalog Saving system catalog containing 9 bundles
    22 Jul 2010 09:33:01 ERROR BundleTransaction Novell.Zenworks.Zmd.BUNDLE_INSTALL_ERROR: Novell.Zenworks.Zmd.BUNDLE_INSTALL_ERROR
    Novell.Zenworks.Zmd.Public.ZenException: 'PreInstall' script failed with exit code '1'
    22 Jul 2010 09:33:01 INFO Progress Progress.Stop Message: Bundle transaction failed: 'PreInstall' script failed with exit code '1'
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 ERROR BundleManager Transaction failed: Bundle transaction failed: 'PreInstall' script failed with exit code '1'
    22 Jul 2010 09:33:01 INFO Progress Progress.Stop Message: Parent failed/aborted
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 INFO Progress Progress.Stop Message: Parent failed/aborted
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 INFO Progress Progress.Stop Message: Parent failed/aborted
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 INFO Progress Progress.Stop Message: Parent failed/aborted
    22 Jul 2010 09:33:01 DEBUG Progress Is Stopped value: False
    22 Jul 2010 09:33:01 ERROR ActionManager Failed to execute scheduled action (install (bundles=3ba56c5bc95bb2874273a7d0cae07d14)): Bundle transaction failed: Bundle transaction failed: 'PreInstall' script failed with exit code '1'
    Novell.Zenworks.Zmd.Public.ZenException: Bundle transaction failed: Bundle transaction failed: 'PreInstall' script failed with exit code '1'
    22 Jul 2010 09:33:01 INFO BundleTransaction Bundle transaction ended.
    clients: sled11sp1 i586
    server: sles11 x64 + zlm732
    the files are not copied to their destination
    the target directories are available, writable by root (obviously) there are no files with the same name available, adding a trailing slash to the target path does not help (but other bundles have no trailing slash and run ok)
    questions:
    where are the temporary files copied to?
    where/how can i find what might be causing the preinstall error?
    should i delete previous versions of the bundle in zlm

    until you delete the previous version in zlm and do a rug ref... or is this as designed
    When you make changes to the bundle you need to apply them. That creates a new version and then you need to deploy that new version. Apply and deploy are on the same page. But I guess you know that.
    If you already did that and still had problems, it might be the zen loader that needs a little bit more time. Once you hit deploy, a zen queue entry gets created that informs the zen loader to update the bundle xml file in the file repository. That file is delivered to the managed device when it queries for bundle information. So if that bundle xml contains the old version, the client will see that.
    Problems here can be that the zen loader simply needs a few seconds longer then when you change to the device and run rug ref. Or there can be other queue entries that get processed and the bundle xml update is just in the queue and waiting. The zen loader has 5 slots for processing queue entries.
    On the zlm server you can run "zlman ql I" for in progress entries and "zlman ql N" for new state entries that ned to be processed.
    Or you can use the short script I posted (Cool Solutions: Monitor ZLM queue entries with Nagios) that shows you in one line how many and what type of queue entries currently exist. This is what I always use to get a overview about the queue status.
    Rainer

  • Hello, iam using the latest version of firefox, whenever i login into my yahoo mail account i get a stop script error, the details of the error script is mentioned below , please suggest how to stop this : STOP ERROR

    Hello, iam using the latest version of firefox, whenever i login into my yahoo mail account i get a stop script error, the details of the error script is mentioned below , please suggest how to stop this
    the website is www.mail.yahoo.com. i was getting the same STOP script error every now and then in firefox 6 as well

    I have had a similar problem with my system. I just recently (within a week of this post) built a brand new desktop. I installed Windows 7 64-bit Home and had a clean install, no problems. Using IE downloaded an anti-virus program, and then, because it was the latest version, downloaded and installed Firefox 4.0. As I began to search the internet for other programs to install after about maybe 10-15 minutes my computer crashes. Blank screen (yet monitor was still receiving a signal from computer) and completely frozen (couldn't even change the caps and num lock on keyboard). I thought I perhaps forgot to reboot after an update so I did a manual reboot and it started up fine.
    When ever I got on the internet (still using firefox) it would crash after anywhere between 5-15 minutes. Since I've had good experience with FF in the past I thought it must be either the drivers or a hardware problem. So in-between crashes I updated all the drivers. Still had the same problem. Took the computer to a friend who knows more about computers than I do, made sure all the drivers were updated, same problem. We thought that it might be a hardware problem (bad video card, chipset, overheating issues, etc.), but after my friend played around with my computer for a day he found that when he didn't start FF at all it worked fine, even after watching a movie, or going through a playlist on Youtube.
    At the time of this posting I'm going to try to uninstall FF 4.0 and download and install FF 3.6.16 which is currently on my laptop and works like a dream. Hopefully that will do the trick, because I love using FF and would hate to have to switch to another browser. Hopefully Mozilla will work out the kinks with FF 4 so I can continue to use it.
    I apologize for the lengthy post. Any feedback would be appreciated, but is not necessary. I will try and post back after I try FF 3.16.6.

  • Why does this script fail with OS X Lion?

    The following AppleScript has been woorking just fine ronning Snow Leopard. Under Lion only the first site is loaded and the other Safari tabs are Untitled. Does anyone know what is wrong and how do I fix it? Thanks for any help.
    Hugh
    ---------------------------------------------------- Non-working script ---------------------------------------------------------------------
    tell application "Safari"
              open location "http://www.macrumors.com/"
              tell window 1 to set current tab to make new tab with properties {URL:"http://www.macworld.com/"}
              tell window 1 to set current tab to make new tab with properties {URL:"http://www.macnn.com/"}
              tell window 1 to set current tab to make new tab with properties {URL:"http://reviews.cnet.com/macfixit/?tag=mfiredir"}
              tell window 1 to set current tab to make new tab with properties {URL:"http://www.macintouch.com/"}
              tell window 1 to set current tab to make new tab with properties {URL:"http://arstechnica.com/apple/"}
              tell window 1 to set current tab to make new tab with properties {URL:"http://www.appleinsider.com/"}
    end tell

    Does anyone know what is wrong and how do I fix it?
    Actually, I don't know why your script fails with Mac OS X Lion. I can only suggest the following workaround, which seems to work properly:
    set myURLs to {"http://www.macworld.com/", "http://www.macnn.com/", "http://reviews.cnet.com/macfixit/?tag=mfiredir", "http://www.macintouch.com/", "http://arstechnica.com/apple/", "http://www.appleinsider.com/"}
    open location "http://www.macrumors.com/"
    tell application "Safari"
        activate
        tell window 1 to repeat with thisURL in myURLs
            set current tab to make new tab
            my newTab(thisURL)
        end repeat
    end tell
    on newTab(theURL)
        tell application "System Events"
            keystroke "l" using command down
            keystroke theURL & return
        end tell
    end newTab

  • While adding/Changing member in planning it gives the error "The SQL operation failed with an error code: 0"

    Hi,<BR>While adding/Changing member in planning it gives the error "The SQL operation failed with an error code: 0" and not allowing any of the changes. I am not able to open the forms giving the error as "Fiscal Days Input - is invalid". Interestingly one form was opening, when the Page selection is changed it also started giving error as like "Fisacal Days Input(form name) - is invalid check log for details". <BR>Pls advice us that what is this error and how to resolve this.<BR><BR>And Which log is to be referred for the details.<BR><BR>Thanks<BR>Ravi

    If a form is invalid it generally means that one of the dimension references is missing.<BR><BR>Can you get in to edit the form?<BR>If you can, see if you can preview it. I suspect you will not be able to.<BR><BR>If not, check all dimension boxes have at least one member against them.<BR>If you have multiple rows and/or columns check all of them too.<BR><BR>I've had a couple of forms in dev "drop" a dimension reference but only once or twice so not enough to reproduce or find out what is causing it. Each time I got the "form invalid" error message and managed to fix it.<BR><BR>Hope this helps.<BR>

  • SCOM 2012 SP1 - PowerShell Script failed to run - 3 alerts appear after every reboot of the SCOM Server

    Brand new SCOM 2012 SP1 install with Update Rollup 1 applied
    Single server, local SQL install, SQL Server 2012 SP1
    Hyper-V VM running on Server 2012.  VM has 8GB Ram, single vCPU
    Going through initial management pack importing and configuration, at this point I have the Windows Server 2012 and SQL 2012 MP's installed.
    See screenshot
    http://i.imgur.com/l0Molh1.png
    I am getting the following alerts in my SCOM console and cannot find a resolution to fix the issue.  I don't want to set an override, as an override will prevent the PowerShell alert in other instances, where I might want to receive an alert.
    Looking at the alert description, it states "The Data Access service is either not running or not yet initialized"
    The SCOM Console launches and responds fine, and I get no other errors.  I check the Data Access service and it is online.  I have left the system alone for a couple of hours and no other errors.  I then closed those alerts and restarted the
    server, and they came right back in, so I know that this is something that is happening at either server startup of during the start of the SCOM services.
    Is it possible that SCOM is trying to execute these scripts and the Data Access service has not come online yet?
    Has anyone else come across this before?

    Please try the method in the following thread:
    Note: As there is operations related to Registry, please perform a backup before doing this.
    OpsMgr 2012 - Power Shell Script failed to run 
    http://social.technet.microsoft.com/Forums/de-DE/systemcenterde/thread/4be37f8d-1e7b-450c-8cb9-f1e95f3b2bd0/
    Thanks.
    Nicholas Li
    TechNet Community Support

  • Powershell script monitor with encrypted password

    I have created a powershell script based monitor in my management pack and everything is ok but I can't get my credentials work inside the script. I want to open pssession to another computer with my credentials. I have triple checked that my pssession is
    working because I can access it from powershell console.
    This works perfectly at local server from PSconsole:
    $EncryptedPassword ="01000000d08c9ddf0115d1118c7a00c04fc297eb01000000534b2....etc...etc..."
    $pw = convertto-securestring -String $EncryptedPassword
    $cred = new-object System.Management.Automation.PSCredential -argumentlist "MyDOMAIN\MyACCOUNT",$pw
    $s = New-PSSession -ComputerName "MyServer" -Port MyPort -Credential $cred
    But when I run the same lines inside my management pack the convertto-securestring
    does nothing, it just wont convert the encrypted password to secure string!
    I have tried this plain text method and it works
    inside my management pack, but I don't want to use it because you can see the password in plain text:
    ConvertTo-SecureString -String "myPlainTextPassword" -AsPlainText -Force
    This is the $error variable, so it's basically says that I don't have anything in the password secure string variable because the convertion did not work for some reason:
    The argument is null. Provide a valid value for the argument, and then try running the command again. Cannot process argument transformation on parameter 'Credential'. PromptForCredential Exception calling ".ctor" with "2" argument(s):
    "Cannot process argument because the value of argument "password" is null. Change the value of argument "password" to a non-null value." The system cannot find the file specified. Exception calling "SecureStringToBSTR"
    with "1" argument(s): "Value cannot be null. Parameter name: s" The system cannot find the file specified. Exception calling "SecureStringToBSTR" with "1" argument(s): "Value cannot be null. Parameter name: s"
    The system cannot find the file specified. 
    So is there some known issue with SCOM Agent / management pack when you are dealing with convertto-securestring
    function with encrypted passwords?
    I used these methods to encrypt the password: Technet article about encryption

    I got it to work!
      <TypeDefinitions>
        <EntityTypes>
          <ClassTypes>
            <ClassType ID="MyClass" Accessibility="Public" Abstract="false" Base="Windows!Microsoft.Windows.LocalApplication" Hosted="true" Singleton="false" Extension="false"
    />
          </ClassTypes>
        </EntityTypes>
        <SecureReferences>
          <SecureReference ID="MyRunAsAccountProfile" Accessibility="Public" Context="System!System.Entity" />
        </SecureReferences>
    <ScriptBody>param (
      [string]$Username,
      [string]$Password
    $API = new-object -comObject "MOM.ScriptAPI" 
    $PropertyBag = $API.CreatePropertyBag()
    $cred = New-Object System.Management.Automation.PSCredential -Argumentlist @($Username,(ConvertTo-SecureString -String $Password -AsPlainText -Force))
    $s = New-PSSession -ComputerName "myserver" -Credential $cred
    Invoke-Command -Session $s -ScriptBlock { $service = Get-Service -Name Spooler}
    $invcom = Invoke-Command -Session $s -ScriptBlock { $service.status}
    Remove-PSSession -Id $s.Id
    if ($invcom.Value -ne "Running") {
    $PropertyBag.AddValue("State","ERROR") 
    $outputLongLine = "Spooler Service is not running on target server!" 
    $PropertyBag.AddValue("Description", $outputLongLine)
    else {
    $PropertyBag.AddValue("State","OK") 
    $outputLongLine = "Spooler is Running on target server."
    $PropertyBag.AddValue("Description", $outputLongLine) 
    $PropertyBag</ScriptBody>
    <Parameters>
    <Parameter>
    <Name>Username</Name>
     <Value>$RunAs[Name="MyRunAsAccountProfile"]/Domain$\$RunAs[Name="MyRunAsAccountProfile"]/UserName$</Value>
    </Parameter>
    <Parameter>
    <Name>Password</Name>
    <Value>$RunAs[Name="MyRunAsAccountProfile"]/Password$</Value>
    </Parameter>

  • Compliance Settings Adobe flash Player disable Automatic Updates Powershell Scripts fail

    Hello,
    I have setup compliance to check and remediate if Adobe flash Player automatic updates is enabled by using PowerShell scripts.
    If I run the scripts below manually on my pc they work fine, but if I run in sccm 2012 compliance I get:
    Setting Discovery Error
    0x87d00327
    Script is not signed
    CCM
    I tried contacting the person that created the scripts, but didn't get a response.
    Discovery Script
    Set-ExecutionPolicy Unrestricted -force
    <#
      This script will check if automatic updates is disabled and return a Compliant/Non-Compliant string.
      Created:     04.08.2014
      Version:     1.0
      Author:      Odd-Magne Kristoffersen
      Homepage:    https://sccmguru.wordpress.com/
      References:
      - Configure auto-update notification Flash Player
    http://helpx.adobe.com/flash-player/kb/administration-configure-auto-update-notification.html
      - Adobe Flash Player Administration Guide for Flash Player 14
    http://wwwimages.adobe.com/www.adobe.com/content/dam/Adobe/en/devnet/flashplayer/pdfs/flash_player_14_0_admin_guide.pdf
      - Adobe Flash Player Administration Guide for Microsoft Windows 8
    http://wwwimages.adobe.com/www.adobe.com/content/dam/Adobe/en/devnet/flashplayer/pdfs/flash_player_13_0_admin_guide.pdf
    #>
    $OSArchitecture = Get-WmiObject -Class Win32_OperatingSystem | Select-Object OSArchitecture
    If($OSArchitecture.OSArchitecture -ne "32-bit")
        $CFGExists = Test-Path -Path "$Env:WinDir\SysWow64\Macromed\Flash\mms.cfg"
             if($CFGExists -eq $True)
             {$UpdateCheck = Select-String "$Env:WinDir\SysWow64\Macromed\Flash\mms.cfg" -pattern "AutoUpdateDisable=1" | Select-Object Line}
                if($UpdateCheck.Line -eq 'AutoUpdateDisable=1') {Write-Host 'Compliant'}
                else {Write-Host 'Non-Compliant'}
    else
        $CFGExists = Test-Path -Path "$Env:WinDir\System32\Macromed\Flash\mms.cfg"
             if($CFGExists -eq $True)
             {$UpdateCheck = Select-String "$Env:WinDir\System32\Macromed\Flash\mms.cfg" -pattern "AutoUpdateDisable=1" | Select-Object Line}
                if($UpdateCheck.Line -eq 'AutoUpdateDisable=1') {Write-Host 'Compliant'}
                else {Write-Host 'Non-Compliant'}
    Remediation Script
    Set-ExecutionPolicy Unrestricted -force
    <#
      This script will check if automatic updates is disabled and return a Compliant/Non-Compliant string.
      Created:     04.08.2014
      Version:     1.0
      Author:      Odd-Magne Kristoffersen
      Homepage:    https://sccmguru.wordpress.com/
      References:
      - Configure auto-update notification Flash Player
    http://helpx.adobe.com/flash-player/kb/administration-configure-auto-update-notification.html
      - Adobe Flash Player Administration Guide for Flash Player 14
    http://wwwimages.adobe.com/www.adobe.com/content/dam/Adobe/en/devnet/flashplayer/pdfs/flash_player_14_0_admin_guide.pdf
      - Adobe Flash Player Administration Guide for Microsoft Windows 8
    http://wwwimages.adobe.com/www.adobe.com/content/dam/Adobe/en/devnet/flashplayer/pdfs/flash_player_13_0_admin_guide.pdf
    #>
    $OSArchitecture = Get-WmiObject -Class Win32_OperatingSystem | Select-Object OSArchitecture
    If($OSArchitecture.OSArchitecture -ne "32-bit")
        $CFGExists = Test-Path -Path "$Env:WinDir\SysWow64\Macromed\Flash\mms.cfg"
             if($CFGExists -eq $True)
             {$UpdateCheck = Select-String "$Env:WinDir\SysWow64\Macromed\Flash\mms.cfg" -pattern "AutoUpdateDisable=1" | Select-Object Line}
                if($UpdateCheck.Line -eq 'AutoUpdateDisable=1') {Write-Host 'Compliant'}
                else {Write-Host 'Non-Compliant'}
    else
        $CFGExists = Test-Path -Path "$Env:WinDir\System32\Macromed\Flash\mms.cfg"
             if($CFGExists -eq $True)
             {$UpdateCheck = Select-String "$Env:WinDir\System32\Macromed\Flash\mms.cfg" -pattern "AutoUpdateDisable=1" | Select-Object Line}
                if($UpdateCheck.Line -eq 'AutoUpdateDisable=1') {Write-Host 'Compliant'}
                else {Write-Host 'Non-Compliant'}
    Thanks,
    Mark

    Hi Jeff,
    You were correct, Default client settings was set to All signed and once I set to bypass, PowerShell Scripts executed.  But now I am getting:    If I run them both from PowerShell, they work fine. Thanks again for your help, Mark
    Error Type
    Error Code
    Error Description
    Error Source
     Enforcement Error
    0x87d00329
    Application requirement evaluation or detection failed
    CCM

  • EM: Creation process for a physical standby DB failed with SQL Exception

    Version: EM Oracle 10.2.5 (agents running, repository running, primary db running, all targets visible and reachable with EM)
    I try to create a physical standby database with the enterprise manager and each time the process is aborted with a SQL exception during the preparation of the job by the EM. I have added a part of the OMs log containing the error at the end of the excerpt.
    =============
    2010-04-29 16:00:39,856 [EMUI_16_00_39_/console/targets] WARN pref.SubtabPref getFolders.710 - Unknown folder id: VirtualServers retrieved from repository
    2010-04-29 16:01:04,765 [EMUI_16_01_04_/console/database/dataguard/create] ERROR em.dataguard validate.1329 - CreateBean: ClassNotFoundException: null
    2010-04-29 16:02:05,476 [EMUI_16_02_05_/console/database/dataguard/create] ERROR jobs.dbclone checkSetFileError.79 - DatabaseFileAttributes.checkSetFileError(): Null database file!
    2010-04-29 16:02:05,476 [EMUI_16_02_05_/console/database/dataguard/create] ERROR jobs.dbclone setControlfiles.160 - DatabaseFileAttributes.setDatafiles(): Invalid control file!
    2010-04-29 16:02:05,492 [EMUI_16_02_05_/console/database/dataguard/create] ERROR jobs.dbclone getControlFileNames.616 - DatabaseFileAttributes.getDatafileNames(): null datafile names!
    2010-04-29 16:02:32,823 [Thread-28] ERROR em.jobs remoteOp.2389 - DBVerify.remoteOp(): Error: max_stamp# 6071384
    2010-04-29 16:02:32,823 [Thread-28] ERROR jobs.dbclone submitJobPreparation.3297 - DBCloneObject.submitJobPreparation(): getMaxLogSequenceNum: Während der Vorbereitung des Jobs ist eine SQL Exception aufgetreten. Um das Problem zu diagnostizieren, legen Sie das Agent Perl-Skript-Tracing auf DEBUG fest und wiederholen den Vorgang
    2010-04-29 16:02:32,823 [Thread-28] ERROR jobs.dbclone submitJobPreparation.3501 - DBCloneObject.submitJobPreparation(): Exception: java.lang.Exception: Während der Vorbereitung des Jobs ist eine SQL Exception aufgetreten. Um das Problem zu diagnostizieren, legen Sie das Agent Perl-Skript-Tracing auf DEBUG fest und wiederholen den Vorgang
    2010-04-29 16:02:32,823 [Thread-28] ERROR jobs.dbclone submitDBCloneJob.3716 - DBCloneObject.submitDBCloneJob(): Exception: Während der Vorbereitung des Jobs ist eine SQL Exception aufgetreten. Um das Problem zu diagnostizieren, legen Sie das Agent Perl-Skript-Tracing auf DEBUG fest und wiederholen den Vorgang
    2010-04-29 16:02:37,496 [EMUI_16_02_37_/console/database/dataguard/create] ERROR em.dataguard onEvent.1243 - CreateConfigController: Exception: oracle.sysman.db.dg.util.VxxStandbyException: Während der Vorbereitung des Jobs ist eine SQL Exception aufgetreten. Um das Problem zu diagnostizieren, legen Sie das Agent Perl-Skript-Tracing auf DEBUG fest und wiederholen den Vorgang
    =========
    I have set the agent perl script tracing to DEBUG, but can't find any reason, why the job preparation failed.
    Has anyone an idea why the job cannot be prepared? Thanks in advance for investigation :-)

    gromit wrote:
    Is there a difference if:
    I install EM Version 10.2.0.1/10.2.0.2 -> upgrade it to 10.2.0.3 -> upgrade it to 10.2.0.5
    OR
    I install EM Version 10.2.0.1/10.2.0.2 and directly upgrade it to 10.2.0.5 ???Hi,
    Both are same. Result will be same. Finally you are reaching 10.2.0.5 version..
    But I would suggest to choose 2nd option.. i.e. install EM Version 10.2.0.1/10.2.0.2 and directly upgrade it to 10.2.0.5.
    Because it will save your time..
    Regards
    Rajesh

  • Powershell script run with TaskScheduler not stopping VM's

    I have a script that stops and starts the VM's, and copies files and it works ok when I run it with powershell, but when I run it with TaskScheduler, it's not stopping/starting the VM's (but does copy files).  We have server 2008 R2.  I updated
    powershell to version 3 and downloaded and installed the Hypver-V powershell module from Microsoft.
    Also, when I run the script through powershell, I needed to run as administrator.  When I run it with the powershell prompt this is what it looks like:
    C:\windows\system32> powershell -NoProfile -noninteractive -ExecutionPolicy bypass -Command "& c:\Scripts\BackupVhdShell_2_param.ps1 -single_backup_file_to_loc 'E:\' -single_backup_file_from_loc 'S:\SQL-bak.vhd'"
    So that works from powreshell to start/stop vm's and copy files.
    In Task Scheduler, this is how I have it set up:
    Run with highest priviledges is checked. I have my login credentials saved so it can wake up the server when I'm not here or if it's not up.  
    In The Program/script field: %SystemRoot%\SysWow64\WindowsPowerShell\v1.0\powershell.exe
    In the Add Arguments field: -NoProfile -noninteractive -ExecutionPolicy bypass -Command "& c:\Scripts\BackupVhdShell_2_param.ps1 -single_backup_file_to_loc 'E:\' -single_backup_file_from_loc 'S:\SQL-bak.vhd'"
    Any thoughts?  I'm not sure if TaskManager isn't finding HyperV module?
    This is what the majority of the script looks like:
    param($single_backup_file_to_loc, $single_backup_file_from_loc)
    function StopVMsInOrder ([array][String]$vmNames){ 
    #this function will stop VM's in list, sequentially 
       Write-Host "Processing virtual machines in order"
       foreach ($name in $vmNames) {
           Write-Host "Analyzing $name"
           Try {
                 #Write-Host "...Saving $name"
                 #Save-VM -VM $name -wait -Force
                 Write-Host "..shutdown $name" #name)"
                 Invoke-VMShutdown -VM $name -Force #$vm.name
           } #try
           Catch {
              Write-Host "Failed to get virtual machine $name"
           } #catch
       }#foreach
    } #function StopVMsInOrder
    function StartVMsInOrder ([array][String]$vmNames){ 
    #this function will start VM's in list, sequentially as opposed to all at once
       Write-Host "Processing virtual machines in order"
       foreach ($name in $vmNames) {
           Write-Host "Analyzing $name"
           Try {
                 Write-Host "..Starting $name"
                 Start-VM -VM $name -wait
           } #try
           Catch {
              Write-Host "Failed to get virtual machine $name"
           } #catch
       }#foreach
    } #function StartVMsInOrder
    function CopyFileToFolder ([string]$Source,[string]$destination){  
       # get filename  
    #################start of script##############
    import-module Hyperv
    #get list of running vm's
    [array]$vmNames = @(Get-VM -Running | %{$_.elementname})  
    Write-Host "To: $single_backup_file_to_loc"
    Write-Host "From: $single_backup_file_from_loc"
    #call function to stop vm's
    StopVMsInOrder $vmNames      
    if($single_backup_file_to_loc -ne " ")
       #someone passed in a parameter for one-off use of script
       [array]$destFileArray = @($single_backup_file_to_loc)
       [array]$sourceFileArray = @($single_backup_file_from_loc)
    }else
       Write-Host "To Loc not Defined as param"
       #get set up for what need to backup vhd's
       #where back it up to
    $i=0
    for ($i = $sourceFileArray.GetLowerBound(0); $i -le $sourceFileArray.GetUpperBound(0); $i++) { 
            $tempSource =  $sourceFileArray[$i]
            $tempDest = $destFileArray[$i]
            CopyFileToFolder $tempSource $tempDest
            Write-Host "i: $i"
    Write-Host "Done with vhd backup"
    #call function to start vm's
    StartVMsInOrder $vmNames  
    Write-Host "Done with vm start"
    Michele Cleary

    I finally figured it out!  I changed it so I was using the 32 bit version of powershell in TaskScheduler:  %SystemRoot%\system32\....  Now it's finding the VM's!
    Michele Cleary
    Just FYI - system32 is x64. SysWOW64 is x86.
    Don't retire TechNet! -
    (Don't give up yet - 12,700+ strong and growing)

Maybe you are looking for

  • Acrobat 9 Pro serial Key fails

    Hello all, I have received 3 different serial keys for Acrobat 9 Pro for my adobe creative suite 3 web premium.  All keys say they are invalid.  Any ideas?  I thought that there was some issue in the registry keys that could be cause this issue, but

  • Nokia Lumia 920

    Hello. why can't I move photos from nokia lumia 920 to iphoto? It's possible?

  • Burn errors on super drive

    Trying to burn DL DVDs and I get the error below. I can burn CDs and SL DVDs no problem. But only when I burn DL is when I get errors. Heres the error The drive reported an error: Sense Key = HARDWARE ERROR Sense Code = 0x09, 0x01 Tracking Servo Erro

  • Problem downloading Photoshop Elements 12

    I was told my a chat rep to uninstall Elements 12 because it was not working correctly and to reinstall.  I have been trying to do this and I run into a dead end.  I can explain more if someone answers.

  • Addition of a partner function

    Hello, I have a customer master to which someone has added a new partner function (Fax partner). However, this was not captured in the changes. Could someone please tell me if this change can be seen somewhere? Thanks very much.