Is Unicode mode for Planning applications allowed in 11.1.2.1? If so how do you allow it?
Seems that it is not allowed but the documentation is ambigious, and a search on the forum does not give clear answer.

Thanks!
But then why does the 8-character limit apply to unicode planning application names?
Shouldn't ticking that checkbox enable longer application names?
What's the limit for unicode Essbase applications, 32 characters? Then one should also be able to give a new unicode planning application a 32 character long name when in the create new planning application dialogue box, given that the data source is 'unicode'.
Edited by: Markus on Aug 4, 2011 5:06 AM

Similar Messages

  • Commands for Planning Applications in WAD?

    Hi all,
    Following the developers' guide on 'Business Planning and Analytical Services'  for 2004S we got stuck on assigning custom Commands for Planning Applications in WAD, which were created in the planning wizard.
    The option for 'Commands for Planning Applications' does NOT show up in the command wizard!
    is there a ABAP/Java stack pre-requisite for this or is there a new(?) authorisation object missing?
    Does it helps for others? On which Java Stack?
    Thx,
    Markus

    Check OSS note 948336.

  • Questions on Commands for planning application

    Hi,
    1. Where can i get the information on commands for planning functions?
    2. What is the difference between
    ---Execute planning function simple and -
    Execute planning function
    3. I create planning layout with few buttons
    a. Copy: I clicked on the copy button and can see the data in the layout
    b. Save: Clicked on the save icon, Data saved into the planning cube
    c. Change. : clicked on the change and changed few values and then clicked on SAVE button. Data got saved into my planning cube.
    Now I my requirement is when user open the planning layout, It should only be in display mode. But currently automatically all the keyfigures are in change mode (Is it because in query designer, I checked "Start query in the change mode?)
    When user opens the planning layout, he should run the copy function, then should save the data into the planning cube and then should be allowed to chagne. Change button should be in active until data is saved into the plannigng cube. IS this possible?
    Thanks
    Annie

    Hi Deepthi,
    Thanks for your reply.
    I did as you mentioned and its working as expected.
    User wants something like this
    1. Execute the planning layout.
    2. Click on the copy function
    3. Save the data
    4. Click on the change button so that data can be changed now.
    As per your solution, without have change button its working perfectly. But now i want to have change button on the layout. Initially change button should be disabled. When i save the data then it should get active.
    I did the following things but didnt work
    1. Save button i have two commands
    a. Save data
    b. Set_item_parameters
    2. Change button> disable>set_data_entry_mode.
    After executing the layout. I could copy the data and save it. BUT after saving it change button is not getting active.
    I think i did do something in save button (B). I just mentioned button group but didnt mention the change button. Can you please help me?
    Thanks
    Annie

  • Fetching data is very slow in workspace for planning application

    Hello Everyone,
    I am working in the web environment of a planning application and recently I have seen some issue's like Fetching data is very slow through webform's and the system will locking automatically and which kick me off from workspace when I refresh.So could you suggest me like what would be the reason's for this issue's.
    Thanks in advance

    Hi,
    Sounds like your form is very large or there are maybe a lot of dynamic calcs on the retrieval. How many rows and columns have you on the form ? Have you dense or sparse dimensions as rows or columns?
    Brian

  • Error to connecting business rules for Planning application outline

    Hi all,
    I recently migrated database schemas from uat to prod.i configured evrything successfully.when
    I loged into EAS console with user(other than admin)that user has all acces to create business rules,
    I tried to create new business rule to select planning application.
    I am getting this error" error connecting to essbase server<servername>:<appname>
    in error details "error connecting to pllanning server<servername>:<appname>"
    and "error loading objects from data source:java.sql.SQLException: [Hyperion][Oracle JDBC Driver]Object has been closed."
    Please anybody help on these
    regards
    vas

    hi john,
    we are using hyperion planning 9.3.1.1.11 version,
    we were new installatalled Production server and configured,but i did not test the business rules in production server,
    next my DBA exported Oracle Dabase Schemas from UAT server to Production sever those scema names are same in UAT and Production server,so my DBA droped The Schemas in production and replaced the UAT scemas in production server,
    After i manually configured the production server with Migrated scemas, in configuration i changed the server names with production sever and Database names while configuration ,Hyperion planning datasource names are same in UAT and Production ,i manually edited the server names and Database names, i configured to For EAS ,Shared Services,Planning
    Everything configured sucessfully,i am able to log on to application Planning url,and refreshed everything,
    But i am logon to EAS console, i tried to create the Business rule with associate Planning Application I am getting this error Connecting to essbase server<server name>:<appname>
    In error details "error connecting to pllanning server,servername>:<appname.
    and error loading objects from datasource:com.java.sqlexception;[hyperion][oracle jdbc driver]object has been close.
    please help on these
    thanking you
    srini

  • Admin owner for planning application migration

    I'm using the instructions from the following article to migrate a planning application. Migration of Hyperion Planning Application One of the steps is create a new Planning application with the same admin name as the older application. Unfortunatly, I'm not sure of what name was used when the application was originally created. Is there someplace where I can find this information.
    Thanks,
    Tom

    Hi,
    Just for your future reference it has been available since version 4.
    In 9.2      
    Select Administration > Application Settings.
    From the Show drop-down list, select Advanced Settings.
    Click Go.
    Select the System Settings tab.
    You will see an option "Select User" > The owner will be in the dropdown.
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Java Processes for Planning Applications

    Hi There,
    We've experienced performance issues where we have reached the limit of the java process for Hyperion Planning - WAS element. My question! Is it possible to create multiple java processes for Hyperion Planning, for example: If we have 7 Planning applications could we have 7 Java processes running - one for each application?
    Thanks
    Mark

    Couple of thoughts on scaling:
    1. Change the mx setting to 1200m -- this is the most you can scale a single instance on 32-bit
    2. Use a 64-bit platform you can set memory settings really high (AIX/Solaris)
    3. Multiple servers with planning on it using a load balancer
    Regards,
    John A. Booth
    http://www.metavero.com

  • Modified Hourglass for Planning Application

    If I have a Planning application with the following dimensions, would a modified hourglass approach be recommended or I have heard that it is sometimes a good idea to keep 'Years' at the top of your Sparse dimensions.
    Current Dimension Order:
    Dim Type
    Dimension
    Total Members
    Stored Members
    Dense
    Account
    381
    242
    Dense
    Period
    35
    13
    NAS
    Years
    7
    6
    NAS
    Scenario
    10
    9
    NAS
    Version
    12
    10
    Sparse
    Building
    60
    58
    Sparse
    Office
    205
    135
    Sparse
    Department
    213
    204
    Sparse
    Job Title
    320
    320
    Sparse
    Employee
    4426
    4426
    Proposed Dimension Order:
    Dim Type
    Dimension
    Total Members
    Stored Members
    Dense
    Account
    381
    242
    Dense
    Period
    35
    13
    Sparse
    Building
    60
    58
    Sparse
    Office
    205
    135
    Sparse
    Department
    213
    204
    Sparse
    Job Title
    320
    320
    Sparse
    Employee
    4426
    4426
    NAS
    Version
    12
    10
    NAS
    Scenario
    10
    9
    NAS
    Version
    12
    10
    I know there is no hard fast order, but was just wondering as far as a Planning application goes if the 'modified' hourglass setup in the 2nd table is a good starting point for trying to gain some performance efficiencies.
    Thanks!
    JRG

    If you are on 11.1.2.2 you don't need to bother about TASKDIMS as it is automatically taken care of. Check this thread CALCTASKDIMS / CALCPARALLEL / Multi - CPU calculation / Performance
    Regards
    Celvin
    http://www.orahyplabs.com

  • Load balancing URL setup for planning application 11.1.2.1

    Hi Gurus,
    There is an existing planning environment with Weblogic/ Oracle HTTP load balancing setup. I just would like to know where would exactly be the generic/ common URL (the URL without actual servername) configured for planning and SmartView?
    Is there any properties file (weblogic/ HTTP) where we will mention those details?
    Thanks,
    Siva

    I am not sure I get what you are asking but planning can be accessed through workspace or by
    http://<ohs_server>:19000/HyperionPlanning
    and Smart View http://<ohs_server>:19000/workspace/SmartViewProviders
    If you want to understand about the configuration you can run a registry report.
    Cheers
    John

  • Unable to use debug mode for x64 application and debug doesn't work when target cpu set to x86

    I am attempting to familiarize myself with Visual Basic programming in Visual Studio 2008, using the Visual Basic Guided Tour in Microsoft Visual Studio 2008 Documentation, and have run into a bit of a road-block.  When following the lesson "It
    Doesn't Work! Finding and Eliminating Run-Time Errors", the IDE does not allow me to edit the code when the debugger hits the intentionally programmed runtime error (divisor set to 0).  It gives me an error that "Changes to 64 bit applications
    are not allowed".  I found some forum postings advising to set the project's Target CPU from "Any CPU" to "x86".  However, when I do that, and re-execute the debug process, the debug fails to stop on the overflow/divide by
    zero error.
    How can I debug my programs when Any CPU/x64 target doesn't allow me to edit the code, and x86 target doesn't appear to recognize obvious runtime errors.

    Hi Tim,
    >>the IDE does not allow me to edit the code when the debugger hits the intentionally programmed runtime error (divisor set to 0).  It gives me an error that "Changes to 64 bit applications are not allowed". 
    I'm afraid that the VS2008 has a limitation for this feature, I mean that Edit and Continue isn't supported on 64-bit.
    Reference:
    http://stackoverflow.com/questions/1498464/changes-to-64-bit-applications-are-not-allowed-when-debugging-in-visual-studio
    http://blogs.msdn.com/b/habibh/archive/2009/10/12/how-to-edit-code-when-debugging-a-64-bit-application.aspx
    But this feature has a improvement in VS2013 now:
    http://blogs.msdn.com/b/visualstudioalm/archive/2013/06/26/debugging-support-for-64-bit-edit-and-continue-in-visual-studio-2013.aspx
    So if possible, you could test it in the latest VS2013 version.
    Best Regards,
    Jack
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • RSE, NRSE, or DIFF mode for my application?

    Hello,
    I am using a pressure sensor that needs 5V supply and generates a 0->2.5V output. I would like to read this voltage using Labview. However I am not sure which mode( diff, RSE, or NRSE) I should use here. I have attached a very simple photo of the way to connecte the sensor ( delivered with the sensor). There is :        1 supply connexion
                 1 Ground connexion
                  1 AGround connexion
                   1 Vout connexion
    I have already tried :
    RSE mode : connecting to ACH and AIGND. I see a 1 to 2mV offset ( compared to a LEM). But I thought this wasn't appropriate in my situation?
    NRSE mode : connecting ACH and AISense. Offset <1.5mV
    ( I haven't tried with any resistance )
    Since the way of connecting this sensor is very common ( I will probably  use this way of connecting again), could anybody tell me what the correct mode is? I have already read answers on the forum and the NI application note about how to use those different modes, but I haven't been able to conclude....
    Any kind of help would be great!
    Thanks,
    Toto
    Attachments:
    Connecting the sensor.doc ‏68 KB

    Bonjour,
    Le problème d'offset peut-être lié à plusieurs paramètres qu'il faut chercher à isoler.
    Quelle est la différence entre le GND et le AGND sur votre capteur? Comment alimentez-vous ce capteur, via le +5V de la carte d'acquisition? Comment calculez-vous cet offset? Avez-vous essayé de connecter des résistances de biais sur les entrées de la carte?
    La note d'application suivante récapitule bier les différents modes de connectique.
    Cordialement,
    DD
    http://zone.ni.com/devzone/conceptd.nsf/webmain/177A8B29FEDC0F5886256FA90083C0F8

  • Outlook for Planning Applications

    At TechEd Berlin in Session EIM202 - Dr Gerd Schoeffl and Detlef Wassmuth presented some slides on Outlook which were not included in the pack. They promissed to publish these on SDN after TechEd but I cannot find them. Could you please let me know where they are?
    Thanks
    Mike

    While session is not present here:
    http://www.sdn.sap.com/irj/scn/vste-catalog?sdn_event_version=sdn_event_teched_version_10
    I would say that you need to contact those two guys in order to remind them.

  • Utility to extract ADS file from Planning application

    Hi,
    We had a Planning System 9.3 Classic application. We wanted to create a replica of the same as an EPMA application. We used a utility to extract ADS file from classic application. Post that the classic application has locked i.e we are not able to edit it. All dimensions are in view mode. Kindly let us know how to revert back in edit mode for classic application.
    Thanks and Regards,
    Meenal Dhall

    Hi,
    I think you have come across the bug in the EPMA extractor, if I remember correctly it changes a value in a table which stops you editing in classic.
    You can resolve this looking at your planning system database.
    There is a table called HSPSYS_PROPERTIES.
    The field property_id is the application id, you find what application it relates to by looking at HSPSYS_APPLICATION
    Once you know the id for your application
    In the table HSPSYS_PROPERTIES look for a row with EDIT_DIM_ENABLED and change the value in the next field from false to true
    Restart planning and you should be able to edit again.
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • BPC 7.5 NW SP 06 Currency Translation - Planning Applications

    Hello Gurus,
    We have created a planning application for internal management reporting and want to enable the currency conversion business rules.  However, for planning applications, we do not need a FLOW type dimension.  But one of the parameters in the currency conversion business rules is the source FLOW.  Therefore, I am not sure if I still have to create a P_FLOW dimension and include it in the planning application, just to be able to perform the currency conversion activities.
    I am curious to know if anyone of you guys has come across a situation like this.  If so, could you please guide me?
    Thanks,
    Van.

    Hi Van,
    Flow is a required dimension for consolidation setup.
    Please check the below link:
    http://help.sap.com/saphelp_bpc75_nw/helpdata/en/5d/9a3fba600e4de29e2d165644d67bd1/frameset.htm
    Thanks,
    Anil

  • Can not copy planning application in EAS?

    the copy option is blanked out for planning application, but fine with other applications.
    this is 11.1.2.3, not see this previous version.

    You can not copy planning application from EAS (Essbase part).. As the application registration is different for Planning and Essbase only applications. Thats why will not be able to register the planning application from EAS as well...
    If you really want to copy Planning application...
    Then LCM, Copyapp.bat/sh can help you ...You need to create new Planning application (Not just essbase part of Planning app).
    Cheers!