Unplanned MIC during result recording

Dear Gurus,
Can anybody tell me what is means by Unplanned MIC.
How do I create the same in Inspection Plan and make result recording.
Srinivasan.

Dear Srinivas,
Normally all MICs are copied from the task list.
The business requirement may arise to include new MIC in the result recording screen.
Any number of MICs can be inserted in the result recording screen.
But deletion is not possible.
As these Master Insp. Char. are not in the original task list,
They are called unplanned MIC.
To add a MIC,in general tab  "+" sign --> you can click.
or Edit --> craete additional Characteristic or F5 in the key board
You will get a pop up window.
Name of the window --> Master Insp. Char. selection
The window contains three line items
1. Master Inspec. Charac. -
2. Plant -
3. Version -
Ex.: MIC : MR001004
Plant :1000
Version : 1
Enter.
We get the next popup window
Name of the window :Change the specification of unplanned char.
Normally you have to mention the "SAMPLING PROCEDURE".
Click "CHECK" BUTTON.
Click "COPY" BUTTON.
We get the message as "Inspection characteristic was created with number 8000"
Similarly next MIC serial number will be 8010.
ie 8000, 8010, 8020, and so on.
8000 series clearly indicates that these MICs are created manually in the Result Recording Screen.
When ever you want to check the new requirement ie thro the MIC, create it manually in RESULT RECORDING SCREEN.
This is called "UNPLANNED MIC".
Hope that this is clear.
Raghu Sharma

Similar Messages

  • Error during result recording in QE71

    Hi Gurus,
    I am using inspection point (copy of 150) in my inpection plan. When i am trying to save my result recording in QE71 system giving below error message.
      Insp. Lot       Oper     Charac. no  Sample                    Message text                                        MsgType Message ID     Msg.No.
    80000000196 0010         10                2     You must enter a text for the characteristic result           E          QE             462       C60
    Though i have maintained the resuts.
    Please help to resolve this issue.
    Regards
    Sandip

    You need check the inspection characteristic's control indicator.
    Transaction QP03 (display inspection plan)
    If you set 'Docu. required' in control indicator of inspection characteristic, additional text must always be entered to document the inspection results during results recording for this characteristic.
    Try to change the indicator to 'No documentation' then there will be no more that message in transaction QE71.
    Regards
    Luke

  • Activating defect class during result recording.

    Hello Friends
    I have created Defect class with few codes, during result recording defect class is 'GREY' not allowing to select code (only display).
    I want it's should be available so that one can choose the relevant code from defect class whille doing result recording.
    Kindly provide your expertise comments to do the same.
    Regards
    Swanad

    Dear Swanad
    Please do the following setting
    In Result recording screen  > Go to Setting (Menu button ) > Defect Class on
    By doing this when you do result recording and the reading is out of spec then after the valuation pop up defect class will get popped up. You can select any one of the defect class
    Regards
    Gajesh

  • An MIC is accept and reject at the same during result recording

    Hi,
    If I have a checked sign on both of the Acceptance checkbox and Rejection checkbox (status:2, and valuation: yellow thunder sign icon) during QE51N, what does it mean in term of result recording, defect, and notification, and usage decision?
    I am stuck as I don't know how to treat this MIC.
    thanks
    YY

    Hi Herment,
    There is no such message you mention and the system allow me to save with status 2. However, the valuation field display a Yellow Lightning icon.
    Now that I press the lock button (i.e. close) and clicked the save button, the system does not allow me to make any changes to this MIC, and which means there are two check sign on the Accept and Reject checkboxes now.
    How to deal with it?
    Thanks
    YY

  • QM-Calibration Procedure -Error during Result Recording

    Dear Sir,
    During mapping of Calibration Process in SAP,I am getting error ( status check error ) for Result recording of Inspection lot (QM-Calibration).I have follow all the required steps,I am not getting reason of error,Please Advice.
    Thanks

    Dear
    Maintain in sampling procedure radio button palnt maintainance. then check if ur using inspection plan with inspection point.
    else make sampling management radio button on..
    regards
    SANIL

  • Default defect class during results recording

    Hi all,
    In the inspection plan I have maintained target value 20, lower limit 19 and upper limit 21 for one MIC which has single recording. When I do results recording for the MIC, I entered value 18, 20, 20, 20, 21, 18 was rejected automatically with a defect class Major defect A. Where is the default defect class from? If I want to enter a different one, how to change it?
    The only place I can imagine is the configuration of Catalog 9 Defect Class in which defect class is assigned to each Code, but in my case no Code was selected.
    Please help.
    Thanks.
    Danny

    Hi,
    Follow the path QCC0> Quality planning> Basic Data> Catalog> Define defect class.
    In this field, you can customize the details as per your need.
    Once done, you need to assign it to Plant level setting as told by Rohit.
    ntn

  • Changing specification during result recording.

    Hello,
    Is there any functionality in result recording (QE51N) which allows you to change specification for quantitative  inspection characteristic?
    Example:
    specification 5,0 .. 6,0.  You record result 4,9 and change specification to 4,9 .. 5.0 which causes that valuation of inspection characteristic  is accepted
    Best Regards
    Andrzej

    Hi,
    Once you assigned specifications you can not change the specifications.
    How ever if you are sure every time specifications are changeing then use MIC with incomplete copy model.
    Normally you will be inspecting the material (Physically) first so you will be knowing what specifications will suit to make the RR acceptable.
    But this may not be acceptable to client in all situation.
    Regards,
    NItin

  • Problems during result recording

    Hi,
    I am facing a problem in the result recording in the transactions QA11 for sample management. I make a sample from QPR1 and generate an inspection lot, then go to QA11 or QA32 for result recording. I record the results and save, the status of the inspection lot updates to RREC. But when i display the results or want to change them, the system shows me a blank screen to record the results again. Although the results are saved in the database table QAMR for the lot and the status of the lot is also RREC but on QA11 the system is not showing those and asking me to enter again. One thing is to be noted that this behaviour is for some materials' lots, for other sample management lots all is O.K.

    Hi,
    For Physical semple, when u r going to create any inspection lot Via QPR1, than u r very well known abt this that inspection point always use as far as physical sample is concern.
    So, whenever u execute physical sample  inspection lot via QA11, than during RR system ask u for a new inspection point values and its valuation.
    once u feed the results than lock ur lot by providing UD.
    if lot is opened and u want to feed new data against same lot than system allows for new inspection.
    I hope ur queery resolved
    Regards

  • Warning during Result Recording

    Hi Experts,
                     I want the system to issue a warning if the result recorded is beyond the specification limit(s), how can this be done?plz Suggest..........
    Regards,
    Sunit

    Dear Sir,
                 Thank you sir.but i need to know whether this change in valuation mode will affect any other area.
                           On changing the valuation mode I have actually started  getting problems in other areas. For example I had created an active ingredient based MIC called assay and assigned a class characteristic to it. Now, whenever I am trying to attach this MIC to a new inspection plan, the earlier u201Cfixed sampling procedureu201D is not showing up in the list of available sampling procedures.If I try to force that fixed sampling procedure in that field, I am getting error message u201CValuation mode of the sampling procedure does not match the insp.charac.u201D On analyzing the message it seems either I have to change back to the earlier sample procedure or I need to change the control indicator of the MIC. Again, this being a MIC with a class characteristic, changing some fields in the control indicator are not possible as system grey them out.
    Please suggest how to proceed?
    Regards,
    Sunit

  • Detail confirmation during results recording

    Dear experts,
    How to call the detail confirmation screen for an opeartion from the results recording screen when the confirming the inspection lot quantities and activities.
    Regards,
    ARR

    Hi,
    check which control key in operation u have used.
    it should be activated with confirmation reqd. then only in result recording system will throw the pop-up
    i hope u can do now.
    regards,
    Anil Mahajan

  • How to see MIC number in Result Recording Screen

    Hi,
    During result recording  (thru QE51N/ QA32 ) in result recording screen we see MIC short text but not the MIC number.
    How to get the MIC number during result recording screen?
    Already we have used Info Field for this & get the MIC number Directly in result recording screen but User like to go for other option.
    Thanks in advance.

    I  think  you wont get MIC no instandard SAP

  • RESULTS RECORDING WITH FREE TEXT IN QUALITY MANAGEMENT

    Hi,
    How can I give free text of 300 chars In results recording? For a process order with batch number & recipe, (in which master inspection characteristics are mentioned which are linked to general characteristics.)
    I created characteristics (type CHAR)(which can be used as free text in results recording ) I have created class, assigned chars to class & finally to material. Also assigned MIC to this class chars.
    When I do results recording I need to have these characteristics to be display as free text of 30character width. But since I have to give selected set for this general chars.(which is the system requirement) I have given  selected set while creation of characteristics.
    Due to this I can only select the codes from the selected set. Is there any process in which I can write free text up to 30 cars during results recording in quality module? & those characteristics I want to assign to MIC so that when process order is executed the first operation of quality can be done for RR.
    With Regards,
    Kareena

    Hi Kareena,
    All of first let me make it clear, if you will assign a Class Characteristic to the MIC, then it will become either Qualitative or QNT.
    Now toeards your questions solution.
    Option:-1
    As suggested by Venkatr, make the control indicator "Docu. Req" in the MIC control indicator set, page:-2. for the line item of MIC in the insepction plan.
    So, the system will prompt you a message to insert a text as described by Venkat, where you can enter the Long text also (Check the button available in the lower part of that small window)
    Option:-2
    Create a document type for this purpose, and assign a file, having 300 char. to the MIC, with the help of the "Object Link" function of SAP, avaialble with RR screen also.
    Reagrds,
    Shyamal

  • Result recording configuration with automatic close indicator

    Hi Guys,
    I was testing this automatic result configuration in my system.
    I selected the u201C1u201D (i.e. Automatic Close) Recording Configuration indicator on the plant level in SPRO > QM > Basic Settings > Maintain Settings at Plant Level> plant > Result recording tab > Recording configuration > maintain Automatic Close.
    Next, I entered the three user parameter ID QAE, QAN, and QAS in the user parameter SU3. However, I leave the parameter value for these three ID blank as I donu2019t know what to put in.
    During result recording, I tested this MIC characteristic on both reject and accept scenarios (i.e. fall under lower/upper limit, and fall outside lower/upper limit). To my surprise, nothing happens. In another word, there is no automatic close incurs on the inspection characteristics (i.e. both the accepted and rejected checkbox still remain unchecked even I navigate around, and hit the u201Ccontinueu201D, u201Cbacku201D, or u201Csaveu201D button).
    Further, I have fulfilled the following prerequisite as specified in the SAP help portal on this topic:
    1 - The inspection scope is fixed scope of this MIC.
    2 - I entered the target sample size (i.e. both the value in the u201CInspectu201D and u201CInspectedu201D field is similar).
    3 - I think I should have the authorization because I have entered the three parameter IDs on the SU3.
    May I know what is wrong?
    Can it be the parameter values for the three parameter ID are blank in my SU3? If so, what value I should enter for these three param ID? If not whatu2019s going wrong?
    Thanks
    YY

    Hi Gajesh,
    For some reason, it doesnu2019t work.
    I think I will tell my guys to perform manually pressing the Lock icon button to force it to valuate and also become status 5, since this the two valuation checkboxes, i.e. accept and reject checkbox is either ticked correctly according to the sampling plan setup in the sampling schema.
    Further, I donu2019t see why this extra manual step is so difficult for my worker.
    Thanks for your help
    YY

  • Chaneg log for QM results recorded

    Guys,
    Is there a way to track/view the changes to the results that are recorded for an Master Inspection Charateristic?
    Thanks

    Hi Ameya,
    In creation of  Master Inspection Charateristic,please check the control key setting.
    In that miscellaneous, "RR change Document" check box to be flagged.
    Then u have to assign the MIC to some Plan.
    When Inspection lot is created using this plan, u can change the value during result recording.
    All changes with their change log can be captured.
    Raghu Sharma.

  • Addition of user defined fields in Results Recording screen (QE01)

    HI All,
    We've a business requirement to add user defined fields in results recording screen (Character Overview screen - QE01), so that the user will enter data in user defined fields during results recording. and the data entered in user defined fields should be saved in data base table along with actual results given by the user in order to retrieve data for reporting purpose.
    Please suggest valuable solutions to acheive the requirement.
    Thanks & regards,
    rajesh

    Hi Sujit,
    Thanks for your reply,
    We've tried using the " QEEM0029 User-Exit for Characteristic Overview Subscreen , however with "QEEM0029"  exit, we are only able to add fields to the characteristics overview screen and there is no provision in this exit to save the data entered in the user fields to a table (QALS,QAMR, QASE).
    Please suggest!
    Thanks & regards,
    rajesh

Maybe you are looking for

  • How to install oracle 10g on suse linux

    Hi, can anybody let me kbow how to install oracle 10.2 on suse linux..... i have installed suse linux but couldn;t able to install oracle 10g on the same.... looking for gud suggestion.....

  • Process ID 265

    Hi all, quite often in Activity Monitor I get this message, in red letters: rcd (not responding) Process ID 265 Something to worry about or just let it be? Thanks for input, Tomas

  • Photos has many instances of displaying blank photos, thumbnails?

    My recently setup photos library has a lot of blank images. They show a blank thumbnail and when I open it sometime a picture will load which is something I have already deleted. I am not under "show recently deleted" rather this is happening under t

  • A328 (dual sim) "Contact Binding" not working as expected

    Hi, fellows! On my A328 (dual SIM, Android 4.4.2) I wanted to use "Contact Binding" feature, so, in Settings -> All settings -> SIM management I put: Default Settings section: Voice call = Always ask (possible 3 options: SIM1 | SIM2 | Always ask) Gen

  • Error messgae while saving the Notification

    HI All, We got one requirement, when we are creating the PM Notification (TC: IW21) we are assigning the already exiting PM work Order. After assigning the work order, we are saving the notification. While Saving the Notification the system should ch