Dear All!!
With the following vi. I'm trying to receive a 5V signal in a digital input, using a usb-6009 device.
I would like to use the 5 VCC supply, available in pin 31 of the same device and send it to pin 17, representing line0 of port0. During execution, 'm physically connecting and disconnecting  these pins in order to see the difference in a led indicator. Unfortunatelly, the led is always on, even if both pins are disconnected.
Could somebody help me? I would be very pleased.
Thank you very much in advance,
Miren
Attachments:
proof.vi ‏38 KB

Hi Miren,
"the led is always on, even if both pins are disconnected"
RTFM?!
They use open collector inputs with an internal pullup resistor of 4.7k, so you actively have to pull down the input to GND to see a difference...
Best regards,
GerdW
CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
Kudos are welcome

Similar Messages

  • USB-6009 digital input change detection

    Hi,
      I am trying to acquire digital signals from an ni usb-6009 device using daqmx on labview 8.0. I need to write the signals from a port of the device to an output file only when there is a change in the signals and I am not able to do this successfully. I created a digital task in MAX and was able to select acquisition mode as '1 sample (On Demand) ' only. Any other selection for acquisition mode would result in error 200077 with the following message -
    Measurements: Requested value is not a supported value for this property.
    Property: SampTimingType
    You Have Requested: Sample Clock
    You Can Select: On Demand
    I selected '1 Sample (On Demand)' acquisition mode and was able to see the channel values on running it in MAX as I rotated a device connected to the usb-6009 device. As expected the hex values on MAX were showing up as FF,7F,3F,BF and this pattern was repeated everytime I provided the input by rotating the device.
    Next, I created a simple vi to use the digital task I setup on MAX. I want to be able to record the signals only when there is a change in the digital pattern from the channels.That is when there is atransition from FF to 7F to 3F and so on, the vi should write to an output file and if no change happens, it should not write to file. To do this, I explored the Timing vi and tried using the 'Change detection' mode, but that produced the same error as above. 
    Can anyone please suggest a way to accomplish what I am trying to do ? Any guidance will be a hugely appreciated.
    Thanks
    ~Sej

    All of that effort with sample rates, timing, change detection, etc ciuld have been avoided if you had read the specs. As you finally found out, the device only supports sftware timed i/o and no change detection. You wll have to do your change detection in software this is done with a shift register/feedback loop.

  • USB-6009 Digital Output Current

    You need to have all those grounds connected together - USB-6009 Digital Ground, ULN2003 GND, and the power supply ground. In this case it will not matter how they are connected.  If they are not connected, then one of the devices could be damaged.
    Lynn

    Hi, I'm trying to increase the voltage of the digital outputs of USB-6009 device. I read a couple topics about using a relay but I could not manage it.
    I was thinking to use 5V supply on the card since it has 200mA current on it, but when I use it with open-collector output, it can not switch the relay. When I measure the current between
    5V and ground: 200mA,
    5V and output, I read a value around 30-40 mA.
    Why can't I use that 200mA with an output? This is the relay I'm using.
    If this is not possible, can I use an external 5V supply (with more current) and a digital output to switch the relay without damage the 6009?

  • USB-6009 analog input at certain voltage

    i am using USB 6009
    i want to use a certain voltage to activate something.
    i want to activate a pop up vi inside a case structure at a voltage of 2.9V.
    i want to de activate the case structure at a voltage of 0.13mV - 0.16mV . then the sub vi will close.
    How to setup the DAQMX?
    can provide any help ??
    example will be good.
    pls show where to find the icons. thank you

    Hi Ace,
    There are several examples from the LabVIEW Example Finder (Help»Find Examples...) that describe using limits. I searched "limits" in the Example Finder and found several examples that might help, such as Limit Testing Measurement.vi, Waveform Scalar Limit Comparison example.vi, and Limit Example.vi. In each, you would have to modify it to include data acquisition, but it shows how to take sampled data as you would get from data acquisition and perform a limit test. The Express VI that Jennifer O. suggested will probably be the easiest route, but there are other VIs that could suit your needs, as seen in the other examples. 
    As far as state machines, there is a template built into LabVIEW that can give you a starting point for creating your own state machine. Under the File»New... menu, you can choose the state machine template under VI»From Template»Frameworks»Design Patterns»Standard State Machine template.
    Please let us know if you have any specific questions we can answer about configuring your data acquisition or about a specific VI. I hope this helps!
    Regards,
    Missy S.
    Calibration Engineer
    National Instruments

  • USB-6009 pulse train generation with digital output....

    Hello!
    I've bought a new USB NI-Card (USB-6009) and now I'm trying to adopt an old vi that uses traditional DAQ drivers. I wrote that vi for a PCI NI-Card (PCI-6024E), which has two counters to generate two pulse trains simultaneously. Now I've only one counter and that's why I'm searching for a good way to create pulse trains using a digital output! The pulse trains are both ranging between 100 Hz and 100 kHz.
    I'm sure somebody has an idea how I can solve the probem in the best way
    Kind regards,
    Peter

    You can't do it with this low cost board. Both digital and analog outputs are software timed only. The analog out is rated at only 150  samples/sec and the digital is about the same. You can't even use one of the counters because it is not a hardware timed counter output. It is an event counter only as an input.

  • Usb 6009 multiple analog inputs

    I am currently attempting to sample two different analog inputs at different sampling rates using a USB 6009.  I keep getting the 'resource reserved' error and am wondering if this is not possible using this DAQ.  Questions:
    1.  Does creating two analog input channels on the device cause this error?
    2.  Is it possible to sample at different rates on channels created in the same task?  (i am trying to 'slow down' the second analog input to display switch points to a customer)
    3.  Running multiple analog inputs using independent timing would be better achieved by switching to a higher end DAQ?  If so which would you recommend?
    I have attached my vi.  Thank you in advance for your help. 
    I surf therefore I am....
    Attachments:
    demo_nolvl.vi ‏27 KB

    The DAQ boards only have 1 timing clock for the analog inputs/outputs.  So you can only have 1 sample rate on a given card.  I would recommend just sampling at the highest of the desired rates in a single task.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • How can i connect 24VDC to digital input (usb 6008)

    hello,
    how can i connect 24VDC to digital input (usb 6008), is it possible with some optocoupler?
    thanks

    The 6008 is a static DIO, so speed shouldn't be an issue.  Therefore an optocoupler should work.  Just make sure you get one the meets your specs.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • How to I connect Sourcing digital output from My Interface Board to NI USB 6501 channel configured as Digital input

    When I connect an input to DI channel of USB 6501 card  from my board which has sourcing Output t, iIn the Off state it is not pulled down properly. The volatge on the port in is 2.1V -2.5V based on the pull down resistor on my board. I suspect that  it acts as a voltage divider.
    The state on the card is still show as "HIGH "state, even my sourcing output driver has a pull down  resister.  when I use this interface board for PCI mseries devices it works fine. Do the pull down resister on my sourcing output is not worth. Is this because of pull up resister 4.7k inside USB card 6501.
    USB 6501 specifications shows the Digital input accepts both source and sink modes. By default the card is in sourcing digital input mode. How do we can convert this in Sinkind digital input mode.
    Could anyone Please give your suggestions to overcome this issue .
    Thanks you.

    You really should not have both a pull up and pull down on the same line.  Really weird things can happen.  If you insist on having a pull down on your board, then I highly recommend putting a digital buffer chip between the DAQ and your board.
    Some boards with DIO have a pull up, while others have pull down.  You just have to watch the specs.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • USB 6009 - Calibration of Analog Input (Mac)

    Hi,
    I have recently acquired a NI USB 6009. I'm using it under labview 7.1 on Mac OS X 10.4 (Tiger).
    I can run the software examples and the datalogger without problems. However, the device seems
    not to be properly calibrated, and I can't figure out how to do it from the manual. When I connect
    pin 1&2 (analog in 0) to pin 32 and 31 (GND and 5V ref voltage) the software claims that the
    measured voltage it ~3.7V (a multimeter confirms that it is in fact 5.0V). Can anyone help
    trouble shooting this ?
    Thank you in advance,
    Niels

    A little update : After thinking some more I realized that it's because
    the USB 6009 is in differential mode, and I hadn't connected one pin. Now
    however, I have trouble figuring out where to change/set this. None of
    the programs (e.q. Acquire One Voltage.vi) seems to define this, so where
    is this defined ?
    Thanks,
    Niels

  • USB-6009 activates unwanted 5V digital signal when turning on the computer

    Hello!
    This may be a known issue, but I couldn't seem to find it in the discussion forums.
    As the title describes, upon turning on the computer, the USB-6009 receives power from the USB port and automatically fires 5V from various TTL channels.
    This is problematic, as it persistently activates part of our machinery we have attached.
    This occurs even when plugging in the USB after the computer is powered up.
    The only way to ensure none of the channels are sending 5V outputs is to power up our labview software, and manually send the command to set all TTL channels to 0V.
    Is there a way to default all the outputs to 0 upon receiving power?
    Thanks,
    -Peter

    6008 is a low-cost device, not a high-performance device.
    Build some hardware protection between the DAQ and your equipment to make it fail-safe in the event that the DAQ reinits and pulls all the lines high.  Tristate buffers and inverters help a lot here.
    You can also use the analog output to "turn on" the rest of the circuit - that inits at 1V, set a comparator to trigger above 3V and slam that output to 5 when the rest of your outputs are configured.

  • Usb 6009 continuous analog output

    Hi
    I'm pretty new to Labview, so you may have to bear with me. I have a USB-6009 and I want to generate a continuos analog output voltage. I've got the example you have posted 'Gen Mult Volt Updates-SW Timed_LV7.1 (0 to 4).vi' working and it outputs a continuous sine wave.
    In a similar manner I need to generate:
    1. Ramp up voltage (and ramp down voltage): starting with a continuos constant voltage, which after a period of time linearly increases to another constant voltage, and which allows me to specify the 3 time intervals and the rate of increase.
    2. Pulsations: whereby I can specify the amplitude and time interval of each pulsation
    This is so that I can control voltage to a valve which regulates my pipe flow. In the example I have (one stated above), I do not understand specifically:
    i. Why I need both a 'Software Loop Time (ms)' as well as 'Timeout'
    ii. The 'Sinusoidal Pattern' input which seems to generate data for a sine wave- I can't get a description of that and there are no similar VIs for other waveforms; and what is the function of the two numbers it has?
    iv. How do I change amplitude and time period for the wave?
    iii. What does 'Index Array' do?
    thank you

    Hi there,
    I'm guessing the VI you are using is the one from this KB:
    http://digital.ni.com/public.nsf/allkb/6F2C2B49A89D685C8625711D007BDD64
    i. The software timed loop control is to control the rate at which you change the voltage output.  The timeout on the DAQmx Write VI is the maximum time in seconds the VI will wait to output a sample (eg. if the write buffer is full, the Write VI will wait for it to become available for 'timeout' seconds before outputting an error).
    ii. The sine pattern is just an array constant of doubles that make up the sine wave voltage values, and the for loop adds an offset (of two volts) to every single one of those values. You might want to replace that entire array constant and for loop with a Simulate Signal Express VI (just search for Simulate Sig or look in the Functions >> Input palette) and convert the dynamic data output to an array of doubles.  You can configure the type of waveform, amplitude, and time period from that express VI as well.
    iii.  Refer to previous answer.
    iv.  Index array returns an element of an array based on the index input.  You can turn on the context help and move your mouse over functions to get more help on them.
    I hope that helps!
    Way S.
    NI UK Applications Engineer

  • Usb 6009:connecting the sensor and motor

    Hi there,
    I am new to the labview also the usb-6009. I want to know if I can connect my sensor to the device. The output of the sensor is either analog voltage, pulse width or serial.If I want to use the AN pin, can I just connect the wire to the ADC from the usb or I need to add some circuit before connect it to the usb?also, if I want to control the brushless dc motor with the driver, can I just connect the wire from the motor driver direct to the device? How to connect it?
    Thanks

    You can connect analog voltages directly to the USB-6009 to be measured as long as they do not exceed the input limits (-10V to +10V).
    Connecting the motor directly to the outputs is a bad idea.
    Digital output is 0-5V, 8.5mA
    Analog output is 0-5V, 5mA
    So unless your motor draws less than 5mA (extremely unlikely) you'll blow up your DAQ!
    You will need to buffer the outputs somehow unless you are just driving logic gates.
    It's all on the datasheet... http://www.ni.com/pdf/products/us/20043762301101dlr.pdf
    Message Edited by Troy K on 06-06-2008 02:36 PM
    Troy
    CLDEach snowflake in an avalanche pleads not guilty. - Stanislaw J. Lec
    I haven't failed, I've found 10,000 ways that don't work - Thomas Edison
    Beware of the man who won't be bothered with details. - William Feather
    The greatest of faults is to be conscious of none. - Thomas Carlyle

  • USB-6009 DAQmx parallel devices

    Hello, im using a NI USB-6009. And I have to read two analog Inputs, write two analog outputs and two digital outputs. All this in parallel.
    It works if I connect them successively, but then the VI is too slow for a good measurement.
    So my question is, can it generally work if the dataflow isn't given trough the hole chain, but rather coincidently trough the single parts of the VI?
    Now it doesn't work.
    Solved!
    Go to Solution.
    Attachments:
    NI_USB_2.vi ‏36 KB

    Hi there thanks you very much for the fast answers.
    Now it works very well. First I had a error with the AI's but now I take them together and the error is gone.
    regards
    Moritz
    Attachments:
    NI_USB_3.vi ‏42 KB

  • USB 6009 and DAQmx Base Concerns

    Hello,
    I just received a USB-6009 multifunction DAQ device along with DAQmx Base for use on Windows XP with LabWindows/CVI ver 7.1.  Both the 6009 and DAQmxBase are successfully installed however I have several questions, I hope I am missing something obvious:
    1. The Task Configuration Utility is not needed for use with LabWindows/CVI?  I believe I read this in the Getting Started Guide.
    2. There is no function panel for the DAQmxBase functions?  I even searched the installation CD and found no .fp files.  So the only way to know what functions are available with DAQmxBase is to open the NIDAQmxBase.h file and search through the function prototypes?  Then, to know what a function does it is necessary to open the C Function Reference Manual via the Windows Start button and search for the function name of interest?
    3. When creating a digital input or output channel with DAQmxBaseCreateDIChan or DOChan is it only possible to setup a "channel" as an entire port?  Is it not possible to setup a channel as a single input or output line?  Similarly, once the channel is configured is it only possible to read or write an entire port with DAQmxBaseReadDigitalU8 or WriteDigitalU8?  I was expecting something similar to the DIG_out_line function used in Traditional NI-DAQ where a board number, port number, line number and state are passed so that a signal output line can be set on or off.
    Thanks in advance for the assistance,
    - Aaron

    Aaron T. wrote:
    Hello,   I just received a USB-6009 multifunction DAQ device along with DAQmx Base for use on Windows XP with LabWindows/CVI ver 7.1.  Both the 6009 and DAQmxBase are successfully installed however I have several questions, I hope I am missing something obvious:   1. The Task Configuration Utility is not needed for use with LabWindows/CVI?  I believe I read this in the Getting Started Guide.  
    **The Task Configuration Utility is not necessary, except that there is significant functionality missing from DAQmx Base but present in the utility. That includes a lot of what DAQmx calls "proerties", and includes things like the convert rate for AI scanning.
    2. There is no function panel for the DAQmxBase functions?  I even searched the installation CD and found no .fp files.  So the only way to know what functions are available with DAQmxBase is to open the NIDAQmxBase.h file and search through the function prototypes?  Then, to know what a function does it is necessary to open the C Function Reference Manual via the Windows Start button and search for the function name of interest?  
    **I don't use CVI so I don't know anything about this. It strikes me that even if you have such a panel reading the documentation is a good idea
    3. When creating a digital input or output channel with DAQmxBaseCreateDIChan or DOChan is it only possible to setup a "channel" as an entire port?  Is it not possible to setup a channel as a single input or output line?  Similarly, once the channel is configured is it only possible to read or write an entire port with DAQmxBaseReadDigitalU8 or WriteDigitalU8?  I was expecting something similar to the DIG_out_line function used in Traditional NI-DAQ where a board number, port number, line number and state are passed so that a signal output line can be set on or off.  
    **Well, the ReadMe file says that USB-6008/9 is supported with both Line I/O and Port I/O. On the other hand, the documentation for DAQmxBaseCreateDOChan and DAQmxBaseCreateDIChan say for the lineGrouping parameter, "Always pass DAQmx_Val_ChanForAllLines." So your question is a good one! Perhaps one of the NI engineers can comment on this.
    - Aaron
    Thanks in advance for the assistance,
    John Weeks
    WaveMetrics, Inc.
    Phone (503) 620-3001
    Fax (503) 620-6754
    www.wavemetrics.com

  • Digital Inputs do not record over long time periods

    I am running Signals Express 2009 with a USB-6009.  I have a project that needs to record the states of 8 digital inputs over a 24 hour period.  The inputs typically do not change state for long periods of time.  When I run the project it does record and gather data if I stop it "soon"(I have gone as long as 30 min.)  When I leave it running overnight it does not appear to record anything.

    If you have not already, you should try turning off display updates in the "Operate »Update Signal Views While Running" menu item.  Set this to Update None.  Also, turn off "Prepare log data for viewing" under the Logging part in the Tools » Options dialog.  
    When I ran your project overnight, it ran out of memory.  The first error it threw was "Not enough memory to complete this operation."  The problem was that SignalExpress saved a great deal of data in memory for easy displaying while it's running, but this grows too big when it runs overnight.  The second error was as follows:
    Logging Stopped:
    Logging was stopped because an error occurred with a Step in the Project. 
    If this error is because of a device buffer overflow, you can improve performance by turning off display updates using the "Operate »Update Signal Views While Running" menu item.
    You can also change the way signals are logged by changing the Logging Options in the Tools»Options dialog.  
    Turning off  the "Prepare log data for viewing" will greatly improve performance. 
    Mark E.
    National Instruments
    Schedule a Free 1-Hour online LabVIEW Tutorial with an NI Applications Engineer

Maybe you are looking for

  • Is there a way to silently upload files?

    Ok, so I've taken the plunge. I've started working on an AIR app using Flash CS3. I'm putting together a little app that will keep my online store updated with all the product updates from our wholesaler. This includes parsing a csv file, downloading

  • Printer keeps coming on and off and making noises by itself

    I can go for days without using the HP LaserJet Pro 100 color MFP M175nw but it keeps making noises.   If its supposed to save energy, why is it doing anything at all until I click "print" ???????

  • Unable to execute external OS command in Sm49

    Hi All, I am trying to copy a file from another application server to BW application server.Below are the steps that I followed: 1. Created a Batch file and placed it on the BW application server.Below is the contents of the flat file: xcopy MDHCLST0

  • Not able to add nor edit contact

    Hello, I am not able to add nor edit contact in my handset (BB Curve, 8520). I am able to only delete contacts. Anyone please help to troubleshoot this problem. Thank you regards. Harris Solved! Go to Solution.

  • JHeadstart and multiples developers -best practices-

    Hi, Which is the best way to use JHeadstart when you have a team of several programmers? We’ve seen that several examples have only one “Application Structure File”, therefore it is quite difficult that a group of programmers can work in parallel. Wh