Xml report not working after compiling original standard form FNDRSTND
Dear all,
I add my some code behind the button of view output in standard FNDRSUN.fmb form, I compile it and was working fine. After few days we bounce
the application and realize that xml report are not opening. I take original form and compile it, after bouncing it start working fine.
But when we did the same exercise in production, Problem still persist
Please need your solid assistant.
Thanks
Please post the details of the application release, database version and OS.
Are you saying you can't open XML reports log/output files after you bounce the application services? If yes, what is the error? Can you find any errors in the OPP/CM/DB log files?
Can you share the code you have implemented to view the output files?
Thanks,
Hussein
Similar Messages
-
Reports not working after upgrade to SCCM 2012 R2 -
I am having the same issue described in this post:
http://social.technet.microsoft.com/Forums/en-US/30f185ac-c34e-44ad-87eb-7d180a0d76b8/after-2012-r2-upgrade-some-sql-queries-wont-run?forum=configmanagergeneral
When running reports after upgrading from SCCM 2012 SP1 CU2 to SCCM 2012 R2 I get the following error:
An
error has occurred during report processing. (rsProcessingAborted)
Cannot
read the next data row for the dataset DataSet1. (rsErrorReadingNextDataRow)
Conversion
failed when converting the nvarchar value
'S-1-5-21-1010966800-777871707-395339515-124623' to data type int.
I have removed the Reporting Services Point and reinstalled it with no effect. All reports I try get the error listed above.
Any suggestions?The issue has been resolved. For anyone experiencing a similar issue I will post the fix that worked for us below:
I ended up opening a PSS case and in this instance the problem was the required SQL management provider was not properly registered in WMI, which ultimately meant the reporting point upgrade/install was not able to complete successfully after the upgrade.
As a result the updated reports were not properly being redeployed to the Reporting Service Point.
To diagnose this on the Reporting Service Point look in the srsrp.log for entries indicating of an
Invalid Class, as seen in the example below:
Invalid class SMS_SRS_REPORTING_POINT 11/6/2013 5:47:12 PM 6096 (0x17D0)
Could not retrieve the reporting service name for instance 'RPSERVER' SMS_SRS_REPORTING_POINT 11/6/2013 5:47:12 PM 6096 (0x17D0)
Invalid class SMS_SRS_REPORTING_POINT 11/6/2013 5:47:12 PM 6096 (0x17D0)
Could not stop the reporting service '' SMS_SRS_REPORTING_POINT 11/6/2013 5:47:12 PM 6096 (0x17D0)
Next security configuration at [11/6/2013 5:52:12 PM] SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Root Folder exists SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Successfully checked that the SRS web service is healthy on server SERVERRP.AD.DOMAIN SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Registry change SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Waiting for changes for 1 minutes SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
SRSRP registry key change notification triggered. SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Registry change SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Waiting for changes for 1 minutes SMS_SRS_REPORTING_POINT 11/6/2013 5:47:13 PM 6096 (0x17D0)
Timed Out... SMS_SRS_REPORTING_POINT 11/6/2013 5:48:13 PM 6096 (0x17D0)
The important part is the lines saying Invalid Class and then it timing out, so the RP installation was not completed.
As mentioned earlier the WMI class that was missing or corrupt was the SQL management Provider. To re-register the class we need to compile the MOF file that is available in SQL. In our instance the command to run was:
mofcomp "C:\Program Files (x86)\Microsoft SQL Server\100\Shared\sqlmgmproviderxpsp2up.mof"
Once that was done, monitoring the srsrp.log shows that it could properly detect the SSRS service, stop it and start coping the updated reports and such. After a few minutes the deploy completed, and all the broken reports started working
correctly.
Hope that helps someone else. -
Visual composer report not working after change backend function ?
We already suffered from strange behaviour of visual composer reports totally not functioning at all at some times.
now I made a change in a function which is called in a function that is used by visual composer. after transporting the change the VC report is not working anymore (while the function itself in the backend is working fine)
how comes that the VC report is not working anymore after inside changes of the functions it calls ??
kind regards
arthurAs you have made changes to the function those changes wont be reflected to the VC.so you try to re call the function into VC then it will work fine.
-
Web Crystal Report not working after period of time
Hi
I have had a problem for a long time now on one of our web servers, it's becoming more of an issue lately due to a web site using Crystal more. The problem is that the Crystal Report Viewer does not load after a few hours. If I re ship the main DLL into the Bin folder for the site, then something gets 'reset', and hey presto, Crystal starts working again.
The problem would even arise with a basic CR, with just one Textfield on it (i.e. not show)
Web server is 32 bit Windows Server Web Edition SP 2. Asp.Net project built in VS 2012 against .Net 4.0.
Anyone have any ideas?
Many thanks,
JulianMake sure you are on SP 8
Make sure you are using .Close and .Dispose on your report objects as you get done with them.
What OS? (2003, 2008, 2012)
Provide more info on the following:
The problem is that the Crystal Report Viewer does not load after a few hours.
What does that mean? Errors? Warnings? Behavior? Symptoms?
- Ludek
Senior Support Engineer AGS Product Support, Global Support Center Canada
Follow us on Twitter -
Hi All,
I developed a xml report but it is throwing below error..please help..
the log details are below
Shipping Execution: Version : 12.0.0
Copyright (c) 1979, 1999, Oracle Corporation. All rights reserved.
XXTEST_XML module: XXTEST1
Current system time is 18-JAN-2012 13:01:05
XDO Data Engine Version No: 5.6.3
Resp: 21623
Org ID : 204
Request ID: 5929328
All Parameters: P_org_id=207:P_phys_inv_id=5196
Data Template Code: XXTEST_XML
Data Template Application Short Name: WSH
Debug Flag: N
{P_org_id=207, P_phys_inv_id=5196}
Calling XDO Data Engine...
[011812_010109165][][ERROR] Variable 'P_phys_inv_id' is missing....
[011812_010109165][][EXCEPTION] java.sql.SQLException: ORA-06550: line 2, column 18:
PLS-00103: Encountered the symbol "." when expecting one of the following:
( - + case mod new not null <an identifier>
<a double-quoted delimited-identifier> <a bind variable>
continue avg count current exists max min prior sql stddev
sum variance execute forall merge time timestamp interval
date <a string literal with character set specification>
<a number> <a single-quoted SQL string> pipe
<an alternatively-quoted string literal with character set specification>
<an alternatively
Am posting xml also
<dataTemplate name="XXTEST_XML" >
<parameters>
<parameter name="P_org_id" dataType="character" />
<parameter name="P_phys_inv_id" dataType="character" />
<parameter name="P_REPORT_NAME" dataType="character" defaultValue="XXTEST_XML" />
<parameter name="P_SUB_REPORT_NAME" dataType="character" defaultValue="" />
<parameter name="P_CONC_PROG_SHT_NAME" dataType="character" defaultValue="XXTEST_XML" />
</parameters>
<dataQuery>
<sqlStatement name="Q_MAIN">
<![CDATA[
select pit.tag_number,
pit.subinventory,
loc.segment1||'.'||loc.segment2||'.'||loc.segment3 locatorname,
pit.serial_num Serial_number,
pit.tag_quantity COUNTQTY,
pit.tag_uom uom,
v.FULL_NAME CountedBy,
msi.SEGMENT1||'.'||msi.DESCRIPTION ITEMDescr,
pit.parent_lpn_id ,
o.ORGANIZATION_NAME
from
mtl_system_items msi,
mtl_item_locations loc ,
mtl_employees_view v,
mtl_physical_inventory_tags pit,
org_organization_definitions o
where pit.organization_id = :P_org_id
and msi.organization_id(+) = :P_org_id
and pit.ORGANIZATION_ID=o.ORGANIZATION_ID
and loc.organization_id(+) = :P_org_id
and pit.inventory_item_id = msi.inventory_item_id(+)
and pit.locator_id = loc.inventory_location_id(+)
and pit.physical_inventory_id = :P_phys_inv_id
and pit.counted_by_employee_id = v.employee_id(+)
and v.organization_id(+) = :P_org_id
order by 1
]]>
</sqlStatement>Still this problem as unsolved ? If so, please check the concurrent request parameter which is passed to this Data Template.
-
Visa not working after compile?
Im using visa in my application. Iim doing reading and writing.
My .VI works when its not compiled. And after i have Compiled it it no longer works ive tried looking for any infor on setting up visa.
So now i am here.
Anyone ever have the same problem.
-Kurt
Solved!
Go to Solution.The most common problem with exe vs debug applications is file paths. If you are doing file io and using paths relative to a vi then you will have some trouble. If you are using the same PC then there shouldnt be a problem with visa not being installed. Do you get any error messages to clue you in on the source of the error? Do you have any error handling (passing error clusters and handleing them) in the application?
Paul Falkenstein
Coleman Technologies Inc.
CLA, CPI, AIA-Vision
Labview 4.0- 2013, RT, Vision, FPGA -
After i install Visual-Studio 2013 crystal-report not working
hi
after i install Visual-Studio 2013 crystal-report not working on my Visual-Studio 2010 projects
when i try to open crystal-report i see this:Hi E_gold,
Crystal Reports forum may be a better place for you.
Thanks for your understanding.
We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
Click
HERE to participate the survey. -
IPS event monitor and reports not working
Dear after upgrading my IPS from E3 to E4 the event monitor and reports not working, can you please advice my to solve this issues
Hi All,
Filter settings below:
The filter works partially as I don't get alerts on the IPS itself.
Firewall LOG:
4 Feb 14 2014 15:33:22 39715 514 IPS requested to drop UDP packet from SOURCE_VLAN_NUMBER:/39715 to DESTINATION_VLAN_NUMBER:/514
IPS LOG (when enabled):
evIdsAlert: eventId=1352793300955167909 vendor=Cisco severity=low
originator:
hostId: SSM02
appName: sensorApp
appInstanceId: 1192
time: Feb 14, 2014 15:33:22 UTC offset=0 timeZone=GMT00:00
signature: description=IP Fragment Too Small id=1206 version=S212 type=anomaly created=20030801
subsigId: 0
sigDetails: Too many small IP fragments in datagram
interfaceGroup: vs0
vlan: 0
participants:
attacker:
addr: 172.x.x.x locality=OUT
port: 39715
target:
addr: x.x.x.x locality=OUT
port: 514
os: idSource=unknown type=unknown relevance=relevant
alertDetails: InterfaceAttributes: context="single_vf" physical="Unknown" backplane="GigabitEthernet0/1" ;
riskRatingValue: 50 targetValueRating=medium attackRelevanceRating=relevant
threatRatingValue: 50
interface: GigabitEthernet0/1 context=single_vf physical=Unknown backplane=GigabitEthernet0/1
protocol: udp
Our next step is to make a service policy exception on the firewall itself. We are also considering reloading the IPS device or at least the analysis engine.
Thanks for all your help so far. Any more suggestions are most welcome. I'll keep you up to date.
Regards
Mariusz -
Object is to sync address and calendar between laptop with Max OS 10.4.11 and iPhone. Upgrade of our 10.4.11 laptop to 10.5 is accomplished and we now need to upgrade Quicktime and iTunes; however, the user name and password for the laptop is now not working after the upgrade to 10.5., though it was working prior to the upgrade, for file sharing.
@ BDAqua > I tried your suggestion but no luck. holding opt+command just gave me a blue screen and it rebotted, pushing the disk out of the drive. Yes, the macbook has 1 gb of ram. I realize that the min req. call for 2 gb of ram so i've got an order in for another dimm to put into the machine. Thanks for your suggestions.
@ a_brody > Yes. The machine was plugged into a power source. The disk promts you to do that and i recall aspect this form other installs. Thanks for the reminder tho! ( btw your second post is like greek to me man!)
@ Kuncklesmac > You're right about Snow Leopard being an upgrade from Leopard. I'm aware of this. And yes previously i've been told by Apple that I needed the Box Set (not the family pack. i am using the family pack for OS Snow Leopard) to upgrade my 10.4.11 mac - they never mentioned adding ram but i figured that out on my own and an apple specialist recommended it when i purchased Snow Leopard and confirmed that I coul duse the Snow Leopard to upgarde from Tiger (10.4.11). I've also read extensively (as i said above) that it isn't necessary (always) to buy the box set. Several 10.4.11 users report having upgraded using the Snow Leopard upgrade disk only (not the Box Set) without trouble on intel macs (also see the apple link i posted). So i'm just ondering how they did it and i cannot.
Thanks fo rall yor help! -
Script does not work after download
Hi,
I have build a form in SAP enviornment using Adobe Life Cycle designer, while designing I have been using XML datasource and wrote scripts for different events on the elements of the form, the script works perfectly fine while designing, but fails when downloaded through an application. I downloaded form and to check if the scripts are still there or not, the script was present, but would not simply execute, for ex. while on clicking of button, certain fields on the form are to be hidden, but this would not work.
ex. this.parent.parent.StaticText39.presence
= "hidden";this.parent.parent.STELL_STEXT.presence
= "hidden";
The above scripts work perfect durong designing the form, but would not work after form is downloaded through an applciation. Could any one have answer to wierd behaviour?
Regards,
Shishir.PWas the form saved as a dynamic XML form?
While the default preview in LiveCycle Designer may be set to dynamic XML form, thus providing the dynamic behaviour you are seeking, if the form is not saved as a dynamic XML form Adobe Reader and Acrobat will not respect the changes to the presence property at run-time.
Steve -
Microsoft Excel 2013 add-in not working after update
I have originally posted this question at answers.microsoft.com and have been re-directed to post here. (http://answers.microsoft.com/en-us/office/forum/office_2013_release-excel/microsoft-excel-2013-add-in-not-working-after/298aff03-c90a-4a2a-b67b-07b6f3c7648c)
We are an organization with over 200 users and are currently using Microsoft Office 2013 (Click-to-run install via Office 365 portal), we have noticed that in Excel when we apply the monthly Office update, the add-in (e.g. Analysis Toolpak) would stop working
with the following error message displayed.
I tried updating from 15.0.4631.1004 to 15.0.4641.1003,
15.0.4641.1003 to 15.0.4649.1004, they all gave the same results.
I have checked the captioned file path and it is indeed missing, I think the update mechanism messed up the add-in somehow, a full re-install would fix it as quick or online repair is not doing the trick. This is not the only add-in it is affecting
as there are some 3rd party add-ins are affected as well.
Please advise how we can fix this without needing to re-install Microsoft Office. Thank you!I don't have 365 or C2R so I can't address your main question, so just a few thoughts which may not be applicable in your setup.
Check the addin manager to see if your addins are listed and ticked. If listed (ticked or not) check the registry to see where the location is written, if ticked look here
HKEY_CURRENT_USER\Software\Microsoft\Office\15.0\Excel\Options
and look for keys named OPENx, where x is the order number the addin is loaded
if not "ticked" instead of \Options look in \Add-in-Manager
With a VBA macro or in the VBE's immediate window return
Application.LibraryPath
Assuming you found a listing in the registry do the paths match, if not look in the .LibraryPath to see if the addins got unloaded there into the subfolder \Analysis
If you find the file(s) try un-installing and reinstalling the addins, but browse to the actual folder don't simply tick. If you can't find the files, copy them (from a different system) to the folder indicated by .LibraryPath. In the addin manager uninstall
them if installed, close the manager, open it again and the addins should be listed, tick to re-install.
You say your other addins don't work, I wonder if some mixup has occurred with what Excel thinks is the default path, but note for other addins the default addins path is returned by app.UserLibraryPath
Are you using a Chinese system? -
My 3G connection is not working after updating to iOS 6.1. I have tried all possible solutions like resetting the network , restarting iPad , ...
The same story. No 3G after updating to 6.1. Told my daughter temporarily not to do an update on her iPad with 6.01. We've exchanged SIMs. I inserted her SIM in my iPad - 3G appeared immediately. And my SIM in her iPad with ios 6.01 also WORKS FINE. We use the same provider - Megafon Moscow. After attempting to revert SIMs to original configuration, 3G disappeared on my iPad again. Don't know what's going on with SIM during the update to 6.1
-
SB04100 Sound Blaster Card not working after computer rebuild
=SB0400 Sound Blaster Card not working after computer rebuildZ I did a full disk format and reinstall for a friend on a Dimension 3000, running XP SP3. There is no sound at all. Speakers are good, tested on another system. Model number on the back of the sound card is SB0400, so I assume this is an older 24 bit PCI SoundBlaster card. Although I reinstalled all drivers from Dell, I found no drivers for this. The Creative site has no listing for this model.
Computer does not seem to recognize the card. Have not opened the box yet but I assume if I were to remove and then reinstall the card it would be recognized (?) I then have to find an SB0400 driver.
Does anyone know where I can find an SB0400 driver ? Does the strategy of pulling and reinstalling the card make sense ? (I have really avoided tampering with any of the hardware on this box -- since it is not mine.)Re: SB0400 Sound Blaster Card not working after computer rebuild? Thanks much for your response. Problem solved for now. I removed the board and then reinserted it, after which I was able to download the drivers directly. Some of my difficulty with this whole process has been ) I didn't know there was no working speaker in the computer and 2) I apparently misunderstood the BIOS settings for this. I re-set it up as an add-on board during the troubleshooting process. After loading the driver, I went back to the original setting (don't recall what it was but it was for integrated sound). The setting for integrated sound works fine, with external speakers and the new 24 bit driver. Still some noise (popping and static) but this board shares the bus with 2 other cards one of which is a wireless network card. May be a PCI latency issue but I'm reluctant to change that because the network card is a bit shaky anyway.
Everything works for now -- I'll be glad to get this particular computer out of my house ! -
"F11 System Recovery" during boot does not work after Cloning hard drive.
Problem: “F11 System Recovery” during boot does not work after Cloning hard drive.
HP Envy m6-1125dx UEFI Notebook Computer with GPT hard drive.
Original Seagate Hard Disk GPT 700GB with Window 8.0_64 upgraded to Windows 8.1_64
Startup Menu (F11 System Menu works properly) only on original hard drive.
Following obtained from Disk Management & diskpart in Command Prompt.
GPT Disk <700GB>
Partition 1 WINRE NTFS Primary 235MB/400MB [Recovery]
Partition 2 EFI System FAT32 (LBA) Primary 108MB/260MB [System]
Partition 3 (NONE) Unformatted Primary 128MB/128MB [Reserve]
Partition 4 Main NTFS Primary 90GB/195GB [Primary “C”]
Partition 5 (NONE) NTFS Primary 372MB/450MB [Recovery]
Partition 6 Data NTFS Primary 7GB/475GB [Primary “E”]
Partition 7 NTFS Primary 26MB/350MB [Recovery]
Partition 8 Recovery NTFS Primary 24GB/26GB [Recovery “D”]
I have Cloned the original hard drive to a new HGST 1TB Hard Drive using four different methods (sector by sector):
Acronis True Image 2015
Acronis Backup for PC
AOMEI Backupper Professional
Macrium Reflect
Each time the cloning process completes successfully and has the same original partition arrangement. The computer works properly except when trying to use the “F11 System Menu” key during boot. It gives the following error message:
“Recovery
Your PC needs to be repaired
A required device isn’t connected or can’t be accessed.
Error code: 0xc0000225
You need to use the recovery tools on your installation media. If you don’t have any installation media (like a disc or USB device), contact your system administrator or PC manufacturer. “
Any suggestions why the F11 System Recovery does not work during boot and how to fix the problem would be appreciated. I have does various disk checking and file checking on both the original and new hard drive with no errors.
Thank you in advanced.Hi,
How did you clone the HDD ? One-for-one or different method ?
Regards.
BH
**Click the KUDOS thumb up on the left to say 'Thanks'**
Make it easier for other people to find solutions by marking a Reply 'Accept as Solution' if it solves your problem. -
VMWARE not working after latest kernel upgrade [SOLVED]
I've done a kernel update and after rebooting VMWare was not working. That's "standard", I figured, because I have a new kernel.
So, I run the any_any patch (as usual) to re-configure the VM to the new kernel but this time no joy
Is there anyone else having the same problem?
The error seems to be here:
In file included from /tmp/vmware-config0/vmmon-only/common/hostKernel.h:56,
from /tmp/vmware-config0/vmmon-only/common/task.c:24:
include/asm/page.h: In function 'pte_t native_make_pte(long unsigned int)':
include/asm/page.h:112: error: expected primary-expression before ')' token
include/asm/page.h:112: error: expected ';' before '{' token
include/asm/page.h:112: error: expected primary-expression before '.' token
include/asm/page.h:112: error: expected `;' before '}' token
make[2]: *** [/tmp/vmware-config0/vmmon-only/common/task.o] Error 1
make[1]: *** [_module_/tmp/vmware-config0/vmmon-only] Error 2
make[1]: Leaving directory `/usr/src/linux-2.6.22-ARCH'
make: *** [vmmon.ko] Error 2
make: Leaving directory `/tmp/vmware-config0/vmmon-only'
Unable to build the vmmon module.
R.
Note: Running /usr/bin/vmware-config.pl is of no help either (same error).
Last edited by ralvez (2007-07-28 13:58:06)stonecrest wrote:Yes, and the PKGBUILD works;
You'd rather say "I, myself, me, thinks it works".
Because it does not work for many people, including me.
The modules do build with kernel 2.6.22.X, but the network behaviour using bridged networking is extremely clumsy (used to work fine with 2.6.21.X), and shared folders are a pain in the butt- for example whenever I try to copy a file from the guest to a host shared folder, the guest OS (winXP) comes close to totally freezing, and I have to kill explorer to stop the transaction.
Do you call THAT "works"?
IMO the issues with kernel 2.6.22 won't be addressed before a new VMWare version is out... Until then, yeah... the old version/PKGBUILD works...
I'm close to ditching VMWare in favour of VirtualBox, but a couple of VMWare features (mainly related to low level hardware access) still prevent me from doing so.
Last edited by scarecrow (2007-07-29 13:31:51)
Maybe you are looking for
-
Order of Line Items change when billing
Hi all, For some reason the order of the line items change when billing a salesorder Salesorder line items: 10 20 text line 30 When billing it changes in: 20 text line 21 30 I'm kind of lost on how to solve this. With kind regards, John Waltmans
-
hi everyone! i try to open the bounce window in logic pro 7, but when I do this Logic crash and I have to start Logic again. any good ideas here? from steele
-
Sorry if my english is bad...I wan anybody to help me to solve my problem...my ipad wont turn on,discharge but can connect to pc with ITUNES..I have Do this step Press home and sleep button in 10 sec but still no reaction..in my place dont hve AppleM
-
Event Dispatch Problem With Classes
I have a custom Timer class that pops up an inactivity alert after 3 minutes. The user can then choose 'yes' if they are still editing a record or 'no' if they are done. If they do not respond within 2 minutes of the alert it assumes 'no'. A 'yes' re
-
In Italy, can I use any of the aps on my iPhone 4 when not in range of wifi? Camera, Kindle, Music?