10Gb module uplink for 3750x switch issues

Hi All,
We build a network consists of 3 x 48 ports 3750X switches and this network is uplink to the Core with 10GB uplink.
We bought 3 x 48 port 3750x with 10GB modules  plus enough10GB SFPs.
The problem is for the 10GB module , we can only have 2 x 10GB SFP connections or 4 x 1GB sfp uplinks.
How do we get around with the 3rd switch which need an extra  10GB uplink to the core ?
we do not want to buy another 3750x switch and stack to the third switch to give it more 10GB ports.
Any solution is much appreciated.
Thanks
PLe

Hi,
Can u shar the BOM which includes 10Gig module part  code and a proposed digram which u wanted to deploy.
Vivek

Similar Messages

  • Device Package for 3750X Switches

    Is there a Cisco Works Device Package for the new 3750X switches?  Just bought
    159 3750X-48PS-S switches to go with over 1000 3750G switches.

    Thanks for the correction - I missed them when checking my earlier post.
    3750X's ARE on both the LMS3.2 support list and the LMS4.0 / 4.01 support lists.
    As you mentioned, applying the latest device support package will add them to the fold.

  • CISCO 3750X stacking for 5 switches , only 4 switches are coming in stack

    Dear All,
    I have 5 cisco 3750X switches ,but only 4 switches coming up 5 switches i am unable to see .
    Connection for the switch :Please find the attached snapshot for the stack data connection .
    Also find the snapshot for the stack power connection .
    Please provide your assistance and support to overcome this issue .

    Dear Marvin,
    Thanks for your reply.
    is my connection provided in attachment for data stack are ok .
    i login to Switch # 5 through console 
    following is the result :--
    switch: ?
               ? -- Present list of available commands
             arp -- Show arp table or arp-resolve an address
            boot -- Load and boot an executable image
             cat -- Concatenate (type) file(s)
            copy -- Copy a file
          delete -- Delete file(s)
             dir -- List files in directories
      flash_init -- Initialize flash filesystem(s)
          format -- Format a filesystem
            fsck -- Check filesystem consistency
            help -- Present list of available commands
          memory -- Present memory heap utilization information
        mgmt_clr -- clear management port statistics
       mgmt_init -- initialize management port
       mgmt_show -- show management port statistics
           mkdir -- Create dir(s)
            more -- Concatenate (display) file(s)
            ping -- Send ICMP ECHO_REQUEST packets to a network host
          rename -- Rename a file
           reset -- Reset the system
           rmdir -- Delete empty dir(s)
             set -- Set or display environment variables
          set_bs -- Set attributes on a boot sector filesystem
       set_param -- Set system parameters in flash
           sleep -- Pause (sleep) for a specified number of seconds
            type -- Concatenate (type) file(s)
           unset -- Unset one or more environment variables
         version -- Display boot loader version
    switch: version
    C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(58r)SE, RELEASE SOFTWARE (fc1)
    Compiled Tue 26-Apr-11 06:59 by abhakat
    switch: boot
    Loading "flash:/c3750e-universalk9-mz.122-58.SE2/c3750e-universalk9-mz.122-58.SE2.bin"...flash:/c3750e-universalk9-mz.122-58.SE2/c3750e-universalk9-mz.122-58.SE2.bin: no such file or directory
    Error loading "flash:/c3750e-universalk9-mz.122-58.SE2/c3750e-universalk9-mz.122-58.SE2.bin"
    Interrupt within 5 seconds to abort boot process.
    Boot process failed...
    switch:
    All other 4 switches i can see in stack but not these switches and also the status light for this switches is blinking green  please provide your assistance .

  • 10G Module for 3750X Hotswappable??

    Hey,
    The Cisco documentation seems to be unclear on whether the 10G Module is hotswappable.
    Not
                    Not sure what they are saying here.
    "Although network modules are hot-swappable, we recommend installing a network module before powering the switch."
    http://www.cisco.com/en/US/docs/switches/lan/catalyst3750x_3560x/hardware/install/notes/net_mod_note.html#wp128946
    What do you think?
    Thanks, Pat

    Hi,
    I would agree with the comments above, first the modules are hotswappable, so they are designed to be able to be installed in a running system,however it is always preferable to not install modules in a running environment due to the risk of damaging the connectors.
    Hope this helps.

  • 3750 Stack Switch Issue

    Hi
    I have Stack of 7 3750 Switches. In that Switch 1 is master with 15 Priority and other switches are Member but because of some reason switch 1 rebooted and then Switch 2 becomes Master because it’s having 14 Priority.
    We have 2 uplinks which connected on switch 1 (1/1/1) and switch 6 (6/1/1) Tengig port. Also we have 4 AP connected on switch 6.
    So we observed that the Switch 1 came up and after that 3 AP is disconnected from WLC. if we disconnect the uplink port on Switch 1 (1/1/1) AP will connect the WLC and using uplink 6/1/1 but if we connect uplink port 1/1/1 and disconnect the uplink port 6/1/1 all 4 AP will disconnect from Network.
    We try to connect the Uplink 1/1/1 to Switch 1 other port 1/1/2 but face the same issue. So we reconnect the port 6/1/1 and used the same link which connect on 1/1/1 to switch 7 (7/1/1) and AP will connect on WLC. So as per this troubleshooting we thought some issue with Network Module or Switch of Switch1.
    So we Swap the Network module between Switch1 and Switch7 and connect the uplink on 1/1/1 but face the same issue and if we connect the same uplink on Switch 7 Ap connect to WLC.
    So we thought that Switch is having issue. But before raising an RMA for Switch we observer 1 more thing that. Earlier that when the Switch 1 is Master all 4 AP's connected to WLC and working fine but when the Switch1 became rebooted and Switch2 became Master issue started. So we rebooted the Switch 2 and make switch master and found that while connecting on port 1/1/1 of Switch port AP's are able to connect to WLC and Issue resolved.
    So I wants to know that is there any requirement that If the high priority switch rebooted and after came up it should not be Master then connected uplink will not work.
    Also let us know what’s happen if the high priority switch came up in network. Means it’s will became Master or Menber.

    Just now i Found one bug which is matching on our issue.
    3750x stack fails to update ARP table after reboot causing traffic loss
    BUG ID:-CSCtz98066
    Symptoms: When the master switch (Switch A) is reloaded or loses power and
    rejoins the stack as a member switch, any traffic stream being sent through
    Switch A is unable to be received by the destination because the newly joined
    member is not able to establish an ARP entry for the next hop router/switch.
    Debugs confirm that Switch A does not send a GARP/ARP for the next hop, though
    traffic continues to be sent to the switch.
    Conditions: The symptom is observed when only Switch A has a physical
    connection between the source and destination router/L3 switch. The newly
    elected master (Switch B) does not.
    Workaround: Ping destination from Switch A, forcing ARP request/response.
    Also affected version is 12.2(58)SE and15.0(1)SE2 and we are using IOS 12.2(58)SE.
    So we are going to upgrade the devices by this weekend with IOS 15.0(2)SE5.
    Will update you once we upgraded the switches.

  • Cisco 2960XR uplink to 6509E switch won't work

    I have recently purchased a Cisco WS-C2960XR-48LPD switch, which I am unable to connect back up to my 6509 switch. The only thing I can think of that might be an issue is the fact that the uplink type for the 2960 is 10Gig and the line card back on the 6509 is a 1Gig SFP line card. So, I switched to a 1Gig SFP module in the 2960 switch but to no avail. I then placed the 10Gig SFP back in the 2960 and tried to connect to the Sup2T's 10Gig GBIC uplink connection but  still this did not work.
    6509 Configs (Sup 2T), line card types are WS-X6748-SFP and WS-X6724-SFP, which are 1 Gig SFP line cards
    Interface GigabitEthernet2/3
    switchport
    switchport mode trunk
    switchport trunk allowed vlan all
    2960XR switch Configs
    Interface TenGigabitEthernet1/0/1
    switchport
    switchport mode trunk
    switchport trunk allowed vlan all
    SFP information
    The type of SFP that the 2960 switch came with is a SFP-10G-SR, which is a 10 Gig SFP module. This does not work.
    Type of SFP being used with the 2960 switch for testing is a GLC-SX-MM sfp, which is a 1 Gig SFP module. This does not work.

    1.  I agree with Glenn.  Cisco SFP/SFP+ modules only have one speed.  So your two modules must match or the link won't go up. 
    2.  Depending on the type of line card you are using, the configurtion for Gig 2/3 is missing the command "switchport trunk encapsulation dot1q".  You do not need this command in the 2960XR.

  • Cisco 3750X Switch, Observing change in Running & Startup Config

    Hi, 
    I have a cisco catalyst 3750X switch running with c3750e-universalk9-mz.152-1.E1.bin, where I'm able to see the running configuration & Startup configuration on the device is not in Sync even after saving configuration to the NVRAM.
    Startup Configuration is the one which is required for my network to work properly, but as I'm able to see running configuration is adding some of the configuration which is not actually required in the template. Can anyone help me to get this issue addressed.
    Configuration attached.

    Can you try this command:
    Switch#copy startup-config running-config
    And then check if you are still face the same issue?
    HTH
    Regards
    Inayath

  • Cisco 3750x switch. Turning off a port at night

    Hi everyone,
    I have a question regarding power management for the Cisco 3750x Switches. Is it possible to power down switch ports
    automatically at a specific time and if so how. I would like several Ports to be powered down between 2 and 3 o clock at night.
    Can anyone tell me how i can realise this? (these switches have Energie Wise capabilities)
    I hope to hear from you soon.
    Thanks in advance!
    Kind regards,
    Wouter Platteeuw

    few things to try:
    Go to your email setup, go to the account in question, go to filters, Check the box that says "do not forward messages to the device" Set this back to the default if this doesn't work.
    Something else:  try using the blackberry firewall
    http://btsc.webapps.blackberry.com/btsc/search.do?cmd=displayKC&docType=kc&externalId=KB23877
    I think this will block all email though, but you can take a look at the options.
    Please click the Thumbs Up icon if this comment has helped you!
    If your issue is resolved, please click the solution button on the resolution!
    Every BlackBerry should have BlackBerry Protect, get it now! | Follow me on Twitter | Bring Back BBM Music!

  • Switch in 3750x switch reset

    I have a 3750x switch stack of three switches.
    One of the switches has reset 2 times and rejoined the stack.
    Everything appears to be working fine except that every port light is flashing green light.
    No one touched mode button.
    Is this a warning of some kind?

    Leo
    Thanks again for the help.
    I was also showing this issue to another source and he suggested exactly what you said above."It looks like the switch is having problem keeping power"
    The people at the site say there have been no power surges but I agree that is seems like power is the problem.
    Switch 2 is the master now so I cannot do a session 2.
    switch 1 was the original master and it has only been up for 5 days.
    KBCUK2Stack01#sess 2
    %ERROR: cannot redirect to itself
    KBCUK2Stack01#sh ver
    Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 15.0(1)SE3, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Wed 30-May-12 13:41 by prod_rel_team
    ROM: Bootstrap program is C3750E boot loader
    BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
    KBCUK2Stack01 uptime is 1 year, 37 weeks, 2 days, 2 hours, 7 minutes
    System returned to ROM by power-on
    System restarted at 10:08:26 GMT Sat Nov 24 2012
    System image file is "flash:/c3750e-universalk9-mz.150-1.SE3/c3750e-universalk9-mz.150-1.SE3.bin"
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    A summary of U.S. laws governing Cisco cryptographic products may be found at:
    http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
    If you require further assistance please contact us by sending email to
    [email protected].
    License Level: ipservices
    License Type: Permanent
    Next reload license Level: ipservices
    cisco WS-C3750X-24P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
    Processor board ID FDO1641Z06H
    Last reset from power-on
    9 Virtual Ethernet interfaces
    1 FastEthernet interface
    84 Gigabit Ethernet interfaces
    6 Ten Gigabit Ethernet interfaces
    The password-recovery mechanism is enabled.
    512K bytes of flash-simulated non-volatile configuration memory.
    Base ethernet MAC Address       : E4:D3:F1:BF:C5:00
    Motherboard assembly number     : 73-12551-06
    Motherboard serial number       : FDO164109FB
    Model revision number           : A0
    Motherboard revision number     : A0
    Model number                    : WS-C3750X-24P-E
    Daughterboard assembly number   : 800-32727-03
    Daughterboard serial number     : FDO164013UH
    System serial number            : FDO1641Z06H
    Top Assembly Part Number        : 800-31325-03
    Top Assembly Revision Number    : B0
    Version ID                      : V03
    CLEI Code Number                : COMJR00ARC
    Hardware Board Revision Number  : 0x04
    Switch Ports Model              SW Version            SW Image
         1 30    WS-C3750X-24       15.0(1)SE3            C3750E-UNIVERSALK9-M
    *    2 30    WS-C3750X-24P      15.0(1)SE3            C3750E-UNIVERSALK9-M
         3 30    WS-C3750X-24       15.0(1)SE3            C3750E-UNIVERSALK9-M
    Switch 01
    Switch Uptime                   : 5 days, 15 hours, 12 minutes
    Base ethernet MAC Address       : E4:D3:F1:DC:FC:00
    Motherboard assembly number     : 73-12530-06
    Motherboard serial number       : FDO16410YN5
    Model revision number           : A0
    Motherboard revision number     : A0
    Model number                    : WS-C3750X-24T-E
    Daughterboard assembly number   : 800-32727-03
    Daughterboard serial number     : FDO16410QPM
    System serial number            : FDO1641X18T
    Top assembly part number        : 800-31327-03
    Top assembly revision number    : B0
    Version ID                      : V03
    CLEI Code Number                : COMJV00ARC
    License Level                   : ipservices
    License Type                    : Permanent
    Next reboot licensing Level     : ipservices
    Switch 03
    Switch Uptime                   : 1 year, 36 weeks, 6 days, 2 hours, 19 minutes
    Base ethernet MAC Address       : 30:F7:0D:CD:29:80
    Motherboard assembly number     : 73-12530-06
    Motherboard serial number       : FDO16281H00
    Model revision number           : A0
    Motherboard revision number     : A0
    Model number                    : WS-C3750X-24T-E
    Daughterboard assembly number   : 800-32727-03
    Daughterboard serial number     : FDO16281FSD
    System serial number            : FDO1628V1J6
    Top assembly part number        : 800-31327-03
    Top assembly revision number    : B0
    Version ID                      : V03
    CLEI Code Number                : COMJV00ARC
    License Level                   : ipservices
    License Type                    : Permanent
    Next reboot licensing Level     : ipservices
    Configuration register is 0xF

  • 3750X switches - get the port duplex by SNMP

    Hello,
    I'm trying to get the 3750X switch port duplex state by SNMP. It looks like the only available OID is portDuplex, but this is for operational duplex, not the admin duplex.
    So, if the portDuplex shows full(2) for a port in SNMP, you can't tell if the port is hard set to "full" or auto-negociated to "full".
    As oposed to the CLI, where a "sh int status" command will show "full" for the hard-set ports and "a-full" for ports that auto-negociated to full.
    For port speed, it looks like "portAdminSpeed" OID does the job.
    So, my question is, using SNMP, how can I tell if a port's duplex is hard set or not??
    Thank you,
    Laura

    Hi,
    How to check whether its stack cable problem or stack port problem on respective switch.
    Most of the time the issue is the stack cable and not the port.  Try inserting the cable all the way into the slot.  With 3750x switches the slots are narrow and some times you need a flash light to look to make sure the cable is in all the way.
    If I change the stack priority on switch 2 and switch 1 , do I need to reboot whole the stack so that new priorities for switch 2 and switch 1 would change to new values.
    Yes, reboot the entire stack, after the election switch 2 should be 14 and switch 1 13.
    I would correct the stacking cable issue as well before rebooting.
    HTH

  • HW-MODULE UPLINK SELECT command missing on 4507R+E Sup7-E IOS 15.1(2) SG4

    We have a 4507R+E with dual Sup7-E's running IOS 15.1(2) SG4.  The license level is LANBase.  I am creating the initial configurations for the switch but cannot change the uplink state of the SFP ports on the supervisors.  I tried to run the command HW-MODULE UPLINK SELECT but it is not present.  These are the only option available under HW-MODULE.
    switch(config)#hw-module ?
      module  Specify a linecard slot for the hw-module command
      slot    Specify a linecard slot for the hw-module command
      system  Specify the system parameter
    Is this a license restriction?

    On a 4507R+E, "hw-module uplink select all" is enabled by default, however, because you've got redundant Sup card, the uplink ports 3 & 4 are disabled permanently. 
    This is because the backplane speed of the chassis is 48 Gbps.  So you can only use up to four (4) 10 Gbps interfaces.

  • Re complaint for the same issue

    Below is the issues that I am facing and I mail to lenovo many times but no response from lenovo care, now the issues are getting worse and worse as jut three to\two days back my lenovo kick get shutdown and stuck on Intel logo and then I go to service center located at Nehru place in new Delhi they open my phone and install new software now I just don't know why to install software they open my phone and from that t\day when my phone reaches to 15% to 10 % battery level phone get blank instantly then I have to plug in the charger to again switch it back , this phone is the lenovo flagship model and I purchased two phone same time both phone get replaced one times but the one phone is working fine and but one phone having this serious issue and when I go to service station they every time says that u have to leave phone for two weeks for at least why the dammn I leave my phone to service center for two weeks just for diagnosing the issue without phone there are lots of trouble I have to face in my daily life please look into this matter , as if this matter not resolve by lenovo as soon as possible I definitely go to file a case against lenovo in consumer court, ---------- Forwarded message ---------- From: Lencare <[email protected]> Date: Mon, Dec 23, 2013 at 5:23 PM Subject: RE: re-complaint about the same issue To: MIDH Care <[email protected]> Cc: "******@gmail.com" <******@gmail.com>, "[email protected]" <[email protected]> Hi Team, Please find the E-Mail below, request you to do the needful. __________________________________________________​________ Thanks & Regards, Lenovo Customer Care, India. Please note that any E-Mails with attachments exceeding 10 MB will not reach us due to limitation in the Attachment Size. From: PranjalOctane [mailto******@gmail.com] Sent: Monday, December 23, 2013 12:00 PM To: [email protected]; [email protected]; MIDH Care Subject: re-complaint about the same issue my name is ranjal dutt i purchased lenovo k900 serial number is ****** the issue is that this phone is i am using replaced once just because of the heating and low battery issue , now after replacing and using it after some days i am facing the problems again , the same with some new ones the problems are listed below: 1.low battery backup 2.heating issue 3.hang 4.screen flicker i am using this phone and i am getting only 5 to 6 six hrs of battery backup , and with heating issue , when i am browsing internet or playing any kinda video it get heats so much and battery drains so fast for me it is pain when i ma in need of clicking some pics or surf to internet as there is very low battery backup , my friend also brought this phone with me on same day they also have this same issue but after replacing his phone the problem get solved , kindly see on my issue as if this issues persists again and again how can we refer lenovo phones to other persons ******
    Moderator note: personal information and serial number removed for member's protection.

    why no body here fo replying my issue..........is lenovo is such a bad company

  • Function module used for ENQUEUE_EIQMEL & DEQUEUE_EIQMEL function

    Hi All,
    It should be highly appreciable if any one could please help.
    I need the name of the function module used for ENQUEUE_EIQMEL & DEQUEUE_EIQMEL function.
    waiting for help.
    Thanks
    Shaw

    Hi,
    The names 'ENQUEUE_EIQMEL' and 'DEQUEUE_EIQMEL ' you have mentioned are itself the function modules. Which other FM's you need i didnt understand.
    These are FM to ahndle lock objects 'QMEL'.
    please reframe your question in case of further issues.
    Regards,
    Mansi.

  • Report in DM module (ISU)for Meter removed that have debts &security charge

    I am beginner in  SAP ISU, looking forward for solution , I have a  techno-functional task-  "I need to develope a report in DM module(ISU) for Meter removed that have debts and security charge with generalised Requirement.
    Moderator message: please work yourself first on your requirement.
    Edited by: Thomas Zloch on Feb 20, 2012

    I have just experiences the "beep, beep, beep" after a hard crash.
    The computer is overheating.  The RAM gets hot and everything crashes.
    The system will not restart, all I get is "beep, beep, beep.....beep, beep, beep.....beep, beep, beep.....beep, beep, beep.....beep, beep, beep.....beep, beep, beep.....beep, beep, beep.....beep, beep, beep"
    I pulled the ram, and switched the chips around.  The system is back up without a problem so far.

  • Fireworks CS3 Program Switching Issue

    In the office we have 3 machines using Fireworks CS3 (part of Studio CS3). All the machines are experiencing the issue I am about to describe. Each machine is an Intel Core 2 Duo with 4GB ram. All 3 machines are using Windows Vista.
    We all had the old Vista Aero problem with brushes, and we quickly overcame this by using the "disable desktop composition" fix.
    However, one problem we have never been able to solve occurs when switching between ANY application and Fireworks. There is a delay of at least 20-30 seconds (sometimes more) when trying to swap back to Fireworks. We have being doing various Google & Adobe forum searches regularly over the past 2+ years, looking in vein for a fix, but as yet have still not managed to find a solution or even a record of someone else with the same issue (mainly because out searches are dominated with the old "disable desktop composition" fix). We assumed it was a problem fundemental to CS3 yet still hold out hope for a solution.
    Normally it's not a problem, but when working on websites which involve a lot of graphics edits and/or switching in and out of Fireworks it can quickly add a very frustrating hour or more to a job.
    Recently, I was forced to upgrade to a new computer with Windows 7, and transfered my old CS3 install to the new machine. I was surprised to find that I can switch in and out of Fireworks instantly, much to the frustration of the other guys in the office who are unfortunately stuck with Vista for the time being.
    Is there a fix for this horrible switching delay on Vista and has anyone else here even sufered with the same issue?
    TL:DR - This is not the desktop composition problem with brushes which seems to domnate results when we try to search for a fix, this is a very noticable delay when swapping in and out of Fireworks.

    I'm affraid that didn't help. It actually slowed down the inital launch of the program and it took around 5 minutes for Fireworks to finally start. Once started the program switching issue was still present

Maybe you are looking for

  • Organizing the BI content in Solution manager - preproject activities

    I am looking for suggestions on how to organize the BI content in Solution Manager, this as one of the pre-project activities. How should this be organized to create the BBP. For example: organize creating folder according to the source module Report

  • How to load prepaid simm credits on an iPad?

    The instructions for loading prepaid simm credits for all carriers I know start with the following: 1.) Dial a number and type in the magic numbers, or 2.) Send an SMS text containing the magic numbers to a number. Neither procedure works on an iPad.

  • My iPad book froze/locked up.

    My iPad book froze/locked up.  It works with other applications but the book is stuck on reading a "Post-it" note.  The message on the note went blank.

  • Error Encountered while copying Audio Stream on CAPTIVATE 3

    Using Captivate 3 on Windows 2000 I don't have access to Captivate 4 or a newer version of windows while in the office.. I do have admin rights to my machine. I'm getting error.. Error encountered while copying audio Stream when creating a new projec

  • I am making a movie on my ipad using iMovie, need help with music.

    I have a song that I put into my itunes library and then uploaded it into a dropbox folder.  I have dropbox on all my apple products.  Anyway, I would like to use this song in my imovie project.  How do I get it into imovie from dropbox.  It is a an