Hello,
I have this error when i want to get a VISA session refnum from a viSession handle.
This error occured when the specified class is IviFgen.
The device concerned is a PXI-5402/PXI-5412 (i need to get the model with a property node - Inherent IVI Attribute... from the refnum)
It also occured during a cast (if the class specified is niFgen).
Could somebody help me ?
Thanks !
Attachments:
ErrorLVRT_TestStand.png ‏11 KB

Hi Ggraindo,
This error occured during deployment? Which is the LabVIEW adapter version that you are trying to use, is it the 9.0.1? Do you have other LabVIEW or TestStand versions installed in your computer? This error only occured when you try to used the class IviFgen, or even just with a simple VI?
What is the result of the error cluster from LabVIEW?
Also, can you post a simple exemple to reproduce this issue?
Regards,
Rémi D.
National Instruments France
#adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
>> Les rencontres techniques de NI - Mesures et acquisition de données : de la théorie à la mise en ...

Similar Messages

  • Error -18004; An error occurred accessing the LabVIEW Run-Time Engine DLL. TS 4.2.1 / LV 2010

    When I try to run a VI that is reentrant in parallel execution, I receive this error.  The details of the error is:  LabVIEW:  The property or method is not supported in this version of LabVIEW.
    This is run under the Simple Operator Interface in LV 2010.  The TestStand engine is version 4.2.1 using LV 2010 run-time engine adapter.
    If I save for previous version to LV 2009 SP1 and set the TS adapter to 9.0.1 (2009 SP1), this works.
    Can anyone reproduce this error (bug?) ?
    Solved!
    Go to Solution.

    have you got the latest updates for TestStand using LabVIEW 2010?
    http://digital.ni.com/public.nsf/allkb/7D728B70F167CE088625776E00582C7B?OpenDocument
    Regards
    Ray Farmer

  • -18001: An error occured accessing the LabVIEW ActiveX automation server

    Hi,
    I'm currently investigating a problem with a Teststand 2.0 sequence. The
    sequence makes use of VI's that call methods of an ActiveX. After a few
    successful loops through the test sequence the error "-18001: An error
    occured accessing the LabVIEW (6.1) ActiveX automation server" is brought up
    in Teststand. I think that somehow the ActiveX automation server is dying
    during the execution of the sequence but I don't know where to start
    searching...The problem does not seem to lie within the ActiveX istself, but
    I'm not sure. Using the same ActiveX within a Visual Basic Application and
    performing the same commands several times does not produce a failure. Has
    anybody an idea what could be the problem
    Thanks, Sven.

    Thanks, but I already know these entries from the Knowledge Base. I found no
    help in there and my error text is also not mentioned there.
    JRA schrieb in im Newsbeitrag:
    [email protected]..
    > There is actually a few Knowledge Bases on NI's website which deals
    > with this exact issue. You will probably want to start there.
    > 1. >
    "http://digital.ni.com/public.nsf/websearch/55574CB4E0F326DF862567FD0077E303
    ?OpenDocument">-18001
    > ...
    > 2. >
    "http://digital.ni.com/public.nsf/websearch/D8690EC8044C7B3586256C63005D4D84
    ?OpenDocument">Why
    > do ...

  • Teststand error states that a vi failed to load in the Labview Run-Time Engine

    I am getting an error in teststand that states that a vi failed to load in the Labview Run-Time Engine version '14.0.1'
    If I look at the software loaded on my system with the NI Measurement and Automation Explorer I have Labview Run Time engines for version 2009, 2010, 2011, 2012, 2013, & 2014 on my system.
    How do I get this VI to run on this system when it is called by test Stand?
    Thank you

    The RTE 14.0 was loaded as part of my deployment and after I ran this I got an update notice for the F1 patch which I also loaded.
    I do not have labview loaded on this system, only the run time engines from running my deployment.
    When I launch t he teststand sequence, when it calls the labview VI, I get the following error moessage:
    Error: Failed to load VI 'C:\builds\RelayVoltageMeaure.vi' in the LabVIEW Run-Time Engine version '14.0.1'. LabVIEW: The VI is not executable. This error may occur because the VI is either broken or contains a subVI that LabVIEW cannot locate. Select File>>Open to open the VI and verify that you can run it. VI Path: C:\builds\RelayVoltageMeaure.vi[Error Code: -17600, Failed to load a required step's associated module. ]
    I have attached the teststand sequence if this helps.
    Thanks
    Attachments:
    QuantumDigitalBd.seq ‏13 KB

  • System Error 998 While loading the Labview Run-Time Engine

    Hello.
    I have a DLL made with LV 7.1 I run the dll using a C compiler and works great in WINXP, but cannot run in Win2K. Error is:
    "System error 998 while loading the Labview Run-Time Engin(c:\program
    files\National Instruments\Shared\Labview Run-Time\7.1\\lvrt.dll)
    READVOLTAGE requires a version 7.1 (or compatible) Labview Runtime
    Engine. Please contact the vendor of READVOLTAGE to correct this
    problem"
    READVOLTAGE is my function inside the dll. The runtime is already
    installed. I tried it in another WINXP running machine and works fine.

    This is actually a Microsoft bug with statically loaded DLLs. There are a couple of workarounds for it, and I have included two links below to posts that address this issue:
    Not found error message from LabVIEW runtime when called from VC++ with statically linked MFC
    I get error 998 when calling a LabVIEW buildt DLL from MSVC++
    Kind Regards,
    E. Sulzer
    Applications Engineer
    National Instruments

  • Error on installation of LabVIEW Run-Time Engine 8.5.1: "This application has requested the Runtime to terminate it in an unusual way"

    Hi,
    a colleague in India cannot install the LabVIEW Run-Time Engine 8.5.1 on Windows XP. On attempting to install, an error box is shown, which says:
    (window title)
    Microsoft Visual C++ Runtime library:
    (message box text)
    Runtime error!
    Program: C:\National Instruments Downloads\LabVIEW 8.5.1\Runtime Engine\setup.exe
    This application has requested the Runtime to terminate it in an unusual way.
    Please contact the application's support team for more information.
    http://img529.imageshack.us/my.php?image=runtimeerrorvt7.jpg
    I didn't find any relevant clues for this in NI forums. A search at Google brought me to http://support.microsoft.com/kb/884538/en-us, offering a HotFix to solve the problem. Unfortunately, the installation of this HotFix does not solve the problem.
    Do you know this behavior and do you have any ideas how the problem can be solved?
    Thanks in advance.
    Best regards
    Manuel
    Message Edited by Manuel Häderle on 10-07-2008 10:41 AM
    Solved!
    Go to Solution.

    Hi there
    log in as administrator and kill all processes not needed and try again. I've seen cases where one of these free download tweak applications (like "Memory Defragmentation" and stuff like that) caused that error. 
    Best regards
    chris
    CL(A)Dly bending G-Force with LabVIEW
    famous last words: "oh my god, it is full of stars!"

  • System error 999 while loading the Labview Run-Time Engin

    Bonjour à tous,
    J’ai un PC avec un Runtime LV71.1 qui me retourne l’erreur suivante. Je ne trouve pas d’info sur cette erreur. Une Idée sur la cause ?
    System error 999 while loading the Labview Run-Time Engin(c:\program files\National Instruments\Shared\Labview Run-Time\7.1\\lvrt.dll)
    Luc Desruelle | Voir mon profil | LabVIEW Code & blog
    Co-auteur livre LabVIEW : Programmation et applications
    CLA : Certified LabVIEW Architect / Certifié Architecte LabVIEW
    CLD : Certified LabVIEW Developer / Certifié Développeur LabVIEW
    Résolu !
    Accéder à la solution.

    Bonjour Maxime, merci pour ta réponse qui est très intéressante. Le soft est en LV7.1.1 est fonctionne depuis plusieurs années. Le PC est chez un client, dans un pays très « hostile », je n’ai donc pas accès à ce dernier. Un superviseur local m’a fait le retour qu’après redémarrage du PC ce dernier indiquait un problème, avec photo pour descriptif. Je n’ai pas plus d’info pour le moment. Je viens donc de demander un CHKDSK c: /F
    Luc Desruelle | Voir mon profil | LabVIEW Code & blog
    Co-auteur livre LabVIEW : Programmation et applications
    CLA : Certified LabVIEW Architect / Certifié Architecte LabVIEW
    CLD : Certified LabVIEW Developer / Certifié Développeur LabVIEW

  • System Error 31 while loading the LabVIEW Run-Time Engine

    I'm getting the following error message.  I've attached a screen shot of it as well. 
    System Error 31 while loading the LabVIEW Run-Time Engine (<Pathstuff>\\lvrt.dll)
    I'm trying to update an instrument running Windows95.  What is system error 31?  I can't find anything on it using Google or the forum's search function.
    The instrument is a Romulus-IIIA from Quad Group.  I'm pursuing assistance from them as well.
    Solved!
    Go to Solution.
    Attachments:
    Winzeta Error LabVIEW.JPG ‏17 KB

    Howdy Szandstra,
    Check out this KnowledgeBase article describing what you are seeing.  Follow the steps there to correct the problem.  Have a great day, and let me know if that solution doesn't work for you!
    Sincerely,
    Chris G in AE

  • UNABLE TO LOCATE THE THE LABVIEW RUN-TIME ENGINE.LVBROKERAUX71

    UNABLE TO LOCATE THE THE LABVIEW RUN-TIME ENGINE.LVBROKERAUX71 REQUIRES A VERSION 7.1 (OR COMPATIBLE) LABVIEW RUN-TIME ENGINE。PLEASE CONTACT THE VENDOR OF LVBROKERAUX71 TO CORRECT THIS PROBLEM
    Uninstalled DAQ and reinstalled.  MAX still throws an error. 
    Any Isead besides uninstalling 3/4 of my software?
    Merry Christmas!
    Matthew Fitzsimons
    Certified LabVIEW Architect
    LabVIEW 6.1 ... 2013, LVOOP, GOOP, TestStand, DAQ, and Vison

    To clean up your system, you will need to uninstall the LabVIEW 7.1 run-time engine, and the "LVBroker," and the "LVBrokerAux71" components using the MSI Blast utility.  To obtain this utility, please create a service request for phone or e-mail support, and contact one of our Applications Engineers about this issue.  Thank you!

  • Unable to locate the LabVIEW Run-Time engine

    Using LabVIEW 2011, I have built an executable and installer including the LabVIEW Run-Time engine. I built the app on a 32-bit system. I'm deploying it to a Windows7 64-bit system. When I ran the installer, rebooted, then tried to run the app, I got an error messsage stating "Unable to locate LabVIEW Run-Time Engine", stating that the LVRTE 2011 was needed to run the app, and asking if I want to download from NI. I have tried downloading the RTE and re-installing it, but when I try, I get an error message from the installer stating that there is a newer version of the RTE already installed, and the installer exits! I have tried un-installing the application, but have had no luck removing the RTE. Now I'm stuck. The re-installed executable application says it can't find the RTE, and the RTE installer says there's a later version already installed!
    I can't go forward or backwards!
    Prior to running the installer for this app, I had a working LVRTE for 2011, and was running some other executable LabVIEW programs on the target box. However, since this new application had additional components not included in the original install of the RTE, I built the new installer which included the additional components. Once I ran that installer, my problems began.
    In my frustration, I've tried downloading from NI both the 32 and 64-bit versions of the RTE, and installing them. I realize that the app was built on a 32-bit system, so the 32-bit RTE SHOULD have run it fine, but didn't.
    At this point I have removed the 64-bit RTE using the NIUninstaller. I believe I need to completely remove all 32-bit RTE components and start over, but I have not been able to. The 32-bit RTE does not show up in any un-install utilities I've found.
    What could be causing this problem, and how do I get past it??
    Thank you.

    One thing I did discover in my struggles is that the RunTime engine on the target box needs to be based on the environment of the development box. So if you built the app on a 32-bit machine, you would need to install the 32-bit RTE, even on your 64-bit target box.
    The RTE Uninstaller might not show up in the Windows Add/Remove Programs utility. In my case the 64-bit RTE uninstaller showed up, but the 32-bit did not. The NiUninstaller (C:\Program Files\National Instruments\Shared\NIUninstaller) did list both RTEs for uninstalling, but still didn't get me past the problem.
    I was finally only able to get past the problem by doing a system restore to a point in time prior to my changing of the RTE.
    Good luck.
    Dan

  • MAX giving error - Unable to locate Labview run-time engine

    I have LV 7.1 and 8.5.1 installed on a WinXP pc. No problems until now.
    I installed some support software for a LabJack  interface, which required LV version 6.1 run-time, so I let it install that.
    I now get the error whenever I run MAX:
    "Unable to locate the Labview run-time engine. LVBrokerAux71 requires a version 7.1 (or compatible) Labview run-time engine...."
    After closing the error boxes, MAX seems to work fine. Both versions of Labview also work. I uninstalled run-time engine 6.1 and re-installed version 8.5.1, but that made no difference. I tried to install run-time version 7.1 from the msi file but it would not let me because a later version of the run-time is installed.
    What is LV Broker? Why does it not accept version 8.5.1 run-time engine? Is it possible to have 2 versions of the run-time engine installed, and if so, how?

    Dear CDancer
    Thank you for contacting NI. First of all, you can have as many versions of LabVIEW run time engines you want loaded on your computer without a problem. LV Broker is installed by all drivers that uses LabVIEW testpanels like DAQmx does. In your case it seems that the LV Broker installation is corrupted or has failed. This can be rectified by overwriting the files in the specified directory listed below:
    C:\Program Files\National Instruments\Shared\LabVIEW Broker
    Your directory should look like the screenshot I have attached; labelled LV Broker Directory View
    I have attached a ZIP File that will replace the LV Broker directory. Please try replacing your files with these if different to the screenshot and let me know how you get on. Many thanks.
    Many thanks for using the NI forums and I look forward to your reply.
    Kind regards
    David
    Applications Engineer
    National Instruments UK
    Attachments:
    LV Broker Directory View.JPG ‏57 KB
    LV Broker.zip ‏413 KB

  • Error 1722 when uninstalling Labview run-time engine 7.1.1

    I have been trying to uninstall all NI software so I can start off with a clean slate. I have been going to the control panel under add/remove programs to remove the NI stuff. Everything is gone except the Labview run-time engine 7.1.1. Everytime i try to remove it, i get teh 1722 error followed by the 1603 error. I've tried repairing it but I still get the same results when i try to remove it agian. I've also tried removing it with MSI Blast. This did not work either. I've gone through the registry and manually deleted anything related to NI and that still didn't work. Is there anything else I could try?
    Thanks,
    Nick

    Hey Steve,
    I have tried repairing it through the control panel.
    I tried reinstalling just the run-time engine and it said it was already installed. So I reinstalled Labview 7.1 and repaired the 7.1.1 run-time engine through the control panel. Then I uninstalled everything. Thanks for all your help
    Thanks again,
    Nick
    Message Edited by Nick_C on 03-12-2007 03:57 PM

  • Can I run two separate versions of the LabVIEW Run-Time Engine on one PC?

    Hello, I am curious if anyone knew if it is possibly to install and use two separate versions of the LabVIEW Run-Time Engine on one PC?  I currently have the 2009 Run-Time Engine installed on one machine and wanted to install the 2011 Run-Time Engine as well. I know that you can run two separate versions of the LabVIEW program on one machine, but what about the Run-Time Engine?
    Thanks!
    Solved!
    Go to Solution.

    I'm guessing this is a bug that NI needs to fix.  I see no reason you shouldn't be able to install the run-time engine of an older version.  I'd be interesed in if it allows you to install the older development environment, which also includes the older run-time engine.  There are some command line switches for NI installers as mentioned here:
    http://digital.ni.com/public.nsf/allkb/C361087EE9F20810862577850073128E
    I wonder if there is a force install option.
    Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
    If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

  • Why do different versions of the LabVIEW Run-Time Engine not compatible?

    LabVIEW Run-Time Engine to become more and more big
    Why do different versions of the LabVIEW Run-Time Engine not compatible?
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview
    Solved!
    Go to Solution.

    jwdz wrote:
    LabVIEW2020 ....... ,it look like?
    You need to express your ideas more clearly. We cannot fill in the blanks and read between the lines if the post has no substance.
    jwdz wrote:
    It will affect the future development of LabVIEW, right?
    What is "it"?
    There are many things that affect the future development of LabVIEW, starting with NI management, all the smart people in LabVIEW development, the economy, the LabVIEW users, etc.
    If you are worried about the increasing size of the distribution, the good news is that the cost of data storage and data transmission has dropped much more dramatically. Even though newer versions are bigger due to great and welcome new features, the improvements in infrastructure have actually made the distribution and storage significantly easier over the years and will continue to do so. Trust me!
    Nobody wants to go back to a LabVIEW version that fits on a floppy disk!
    LabVIEW Champion . Do more with less code and in less time .

  • Can I use the labview run-time engine 2010 with my LV 2012 program?

    Hi all,
    I will receive the new Labview Developer Suite 2012 DS2 in a few days and
    I am wondering if it is possible to run LV2012 programs on the LV run-time engine 2010 or is it necessary to update all my clients from run-time engine 2010 to 2012?
    Stay Hungry, Stay Foolish
    Solved!
    Go to Solution.

    Hi Benjamin,
    You will not be able to use the LabVIEW 2010 run-time engine with LabVIEW 2012 applications.  Versions of run-time engines need to correspond with the version of LabVIEW that you have installed.
    The following links direct you to our download pages for the run-time engine:
    The 32-Bit Run-Time Engine can be downloaded from our website as can the 64-Bit Run-Time Engine, depending on which version of operating system you, use by clicking the link under "Standard Download".
    Hope this helps.
    Marshall B
    Applications Engineer
    National Instruments UK & Ireland