3560 Poe switch help needed.

Bought a 3560 poe and its currently running base ip services.
c3560-ipbasek9-mz.122-44
Was asked to download the latest version of Advanced ip services.
Problem is i cant find the the advanced ip services in the latest release section. 12.2.55 Se8 ?
All i see there is IP base and Ip services.
Was "advanced ip services" image replaced by "ip services" image in the lastest releases ? older releases still have a "advanced ip services" image...
Thanks

I dont think i did anything wrong . please correct me if im wrong . i downloaded 122 .44 of the advanced ip services set but havent even put it on the switch yet. its an old ios version and it doesnt require any contract or anything to download. I got it from the official cisco web page. It does everything i need it to do so .... did i do something wrong ? should i not use this image ? Im not selling anything or makin money im just studying for ccnp switch ... finished my ccna couple of months ago...
Please let me know.

Similar Messages

  • Replacing hubs with switches help needed

    I'm new at this so bear with me.
    I have two LANs, 10.0.0.x and 10.1.0.x, connected via firewall/router with 10.0.0.245 and 10.1.0.5 address. Clients and servers are connected to hubs on both networks. I want to replace the hubs with 2960TT switches already purchased but not configured.
    The 10.1.0.x Windows clients have a default gateway of 10.1.0.5 which is the firewall routing to the 10.0.0.x network which then has a default gateway of 10.0.0.253 to Internet.
    I suppose I would like to get rid of the firewall but must I replace it with another routing device or can the switches themselves be configured to allow these two networks to co-exist? I need the 10.1.0.x clients to see the 10.0.0.x network and resources but not vice-versa.
    I need help configuring the switches. Thanks!

    You could likely use your new switches as "drop in" replacements for your hubs with minimal or possibly even no configuration. However, to maintain distinct subnets, you're going to continue to need some type of L3 device, such as your existing firewall/router.
    One issue you might have with your existing firewall/router is it might be performance challenged for traffic moving traffic between your two subnets. (Likely your Internet side is limited by your Internet bandwidth.) If there is a performance issue between your subnets, you might look at obtaining a faster L3 device to either replace your existing firewall/router or in addition to it. (The "in addition to" L3 device, could be an "inexpensive" L3 switch, perhaps the 3560-8PC, to handle LAN traffic, while your existing firewall/router continues to handle Internet traffic. Optimal physical configuration of something like the 3560-8PC with your new switches might be linking your two new switches on a VLAN trunk gig port and one switch to the 3560-8PC also on a VLAN trunk gig port. The existing firewall/router might then connect to the 3560-8PC on one of its 100 Mbps ports.)

  • Momentary punch in/out foot switch help needed

    Hi all,
    I'm looking to find a usb keyboard or device that i can use with LOGIC 9 to plug in a momentary punch in/out foot switch.
    I have an M-Audio Oxygen 61 - but I can't tell if it  has the input or not?
    Thanks in advance

    I might approach it like this..... Open your template song. In the environment, create a new transformer and check the box next to the icon in the inspector so that it shows up as a possible arrange track. Double click the transformer to open it and program it to transform sus pedal (cc#64 I think...) to some other unused controller. Select the transformer track in the arrange page, open your key commands and set the transformed cc data to the record toggle (delete the original sus pedal setting from the controller list). Save the template song with this transformer and arrangement with the transformer track in it. Now when you build a new song from the template, you can select the transformer track when you want to use the pedal for record toggle, and select the appropriate instrument's track when you  want the sus pedal.
    There are probably other (better?) ways of doing this.. one of the best things about logic..... Perhaps some one else will offer up a simpler way. It might just be easier to open KC window and delete the sus/rec. toggle setting when you don't need it and just reprogram it when you do.....

  • SG 200 Switch- help needed setting up vlans

    I am thoroughly confused by all the various modes and settings on this switch, and trial and error has produced little results. Here is what I am trying to do with this switch. First off, it has a management IP of 192.168.100.1. I want 2 subnets to exist on this switch, 192.168.100.x/24 and 192.168.200.x/24. Port 23 I want to m ake an uplink connection to a DMZ interface off a firewall, which will have an IP of 192.168.100.250. Port 24 on the switch will also be an uplink to a second DMZ interface on the same firewall with a 192.168.200.250 ip address. Each of those DMZ interfaces on the firewall will be configured as a DHCP server and will hand down all the subnet settings to each specific subnet. So my question is how do I configure ports 1-22 on my switch, meaning some of my devices on the network I want on one subnet and other ports on the other subnet. And what would I configure for ports 23 & 24 which are my uplink ports to each respective subnet? I had thought I could simply configure 2 new vlan's on the switch, VLAN100 and VLAN200, and then assign whichever ports I want on which vlan, and then I'd make port 23 VLAN100 and port 24 VLAN200, but that has not worked. But there are general ports, access ports, trunk ports, and I am confused on how I would set up my switch in my scenario. Any ideas?

    Hi Mjsully.
    I think I understand what you want.
    Port 24 = 192.168.200.250 = VLAN 200
    Port 23 = 192.168.100.250 = VLAN 100
    Configure port 24 as an access port vlan 200 untagged
    Configure port 23 as an access port vlan 100 untagged
    Configure any additional port as vlan 100 or 200 access untagged to be a member of whatever vlan you wish. Keep in mind these will be 2 separate networks.
    Now, the management of the switch is a little different. The default vlan of the switch is vlan 1. If you wish to have the switch management in the 192.168.100.250 subnet you will have to change the default vlan of the switch to be vlan 100 instead of vlan 1.
    I hope this makes sense. Let me know.
    -Tom
    Please mark answered for helpful posts

  • Cisco 1252s with regular 802.3af PoE switches - what are the impacts?

    Does anyone have any real-life experience with deploying the 1252s on regular 802.3af PoE switches?  I have a few 1252s one some 3560 PoE ports and the show up with "low power" alarms.
    I am wondering what the real world impact is with this scenario.  The 1252s have both 2.4 Ghz and 5.0 Ghz radios in them and I have HT enabled on the controller.
    I'm wondering what capabilities I am losing by running on 802.3af power besides the annoyance of the alarms.
    Thanks in advance!

    Sorry in advance for the book I have just written.
    I have three 1252s on 75 feet of Cat5e cable running to a 3560 PoE switch. Sometimes, but not always, I see a low power alarm on the access point(s). This is in a small building that is built like a fortress so the RF environment is somewhat challenging. I am watching WCS closely and see all three 2.4 GHz radios powered all the way up to power level 1. I notice that two of the 5GHz radios are on power level 1, and one is on level 3. I thought that RRM would not power anything down until you had at least four access points as RF neighbors. I believe I read that in a Ciscopress book and it seems to be true everywhere in our network when I look at buildings with 3 or less WAPs.
    The building in question does not have any other buildings close by with any 5GHz radios in operation - or at least I didn't see any when I did the survey.
    I'm wondering if the power setting of the radios is also related to the length of the Cat5e cabling. Seems to me a shorter run would have less resistance than longer runs, allowing the radio to have more power.
    My main concern is not this building in question, since we went for coverage and not client density in the design. We several other buildings on the radar, all libraries, which are going to be both RF challenging (bookshelves, furniture, cubicles, cubbies) and client-density challenged. These buildings have hundreds of WLAN clients in them at times - and I mean devices, not just people.
    Someone else told me (reputable source) that channel bonding is not an option when on 802.3af power. Makes sense, actually. I would never even think of bonding in the 2.4 GHz range for obvious reasons, but up in the 5GHz range it is a definate possibility in these buildings. Seems to be that we might be shooting ourselves in the foot by not using 802.3at power in these buildings.
    If channel bonding is disabled and the upper two MCS rates (using 800ns guard interval) of 117 and 130 are disabled, then I'm looking at maximum MCS rate of 104 Mbit/s compared to 270 Mbit/s with 802.3at with channels bonded in the 5GHz range.

  • Monitoring Power output on a POE switch

    We just installed 12 AP's on a Cisco 3560 POE switch which currently has 6 AP's already connected to it.
    The Customer is asking us to montior the power consumption on  the switch.
    What are the recommended methods for accomplishing this?
    Thanks You for any input!                  

    Kevin,
    Have a look at this link:-
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst3750/software/troubleshooting/g_power_over_ethernet.html#wp1002308
    Sample outputs of what to look for
    Regards,
    Alex.
    Please rate useful posts.

  • 3560 POE problem

    We are using 3560 POE switches to power Symbol AP's. All the documentation I've read says the 3560 can power up to 24 AP's. We are only able to plug in 7 to 8 AP's before some start dropping out. Is there any other possible cause for this other than lack of power?

    if you do a "show power inline" it should give you info like this
    ACADB-300C-92.3#sh power inline
    Available:370.0(w) Used:109.8(w) Remaining:260.2(w)
    Interface Admin Oper Power Device Class Max
    (Watts)
    Fa0/1 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/2 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/3 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/4 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/5 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/6 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/7 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/8 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4
    Fa0/9 auto on 12.2 AIR-LAP1131AG-A-K9 3 15.4

  • HELP NEEDED!! I bought a brand new mac air 11 inch a month ago, and for three days now I can't switch it on.when I do, i can hear the machine is on, but nothing else happens. (yes it is charged). please help

    HELP NEEDED!! I bought a brand new mac air 11 inch a month ago, and for three days now I can't switch it on.when I do, i can hear the machine is on, but nothing else happens. (yes it is charged). please help.
    I bought it in South Africa and I am currently in Israel.

    thank you for the response.its not working, tried that. i can switch the machine on and off, can hear the machine when i hold it to my ear. but nothing works, not the screen, not the sound, nothing.

  • Help need to switch Muse site to BC on a allready hosted plan

    Hi,  i also posted on BC forum...
    I have a client that was in a hurry to have his emails accounts before the entire website.
    So i went on and bought the email marketing plan (cos he will also need to do email campains) an pointed his domain everything is working fine, at this moment he has his accounts the domain is live.
    The site would be just a small 7-10 pages not to complicated.
    Has a graphic designer (who has venture into Business catalyst cos it had all the solutions i needed, well that's what the promotional videos said anyway) I made a site in Muse.
    First i did a temporary page thats says "comming soon", and then i made the entire site, all the design and menu but with blank pages cos the client didnt have all the content yet (and still dont have). I uploaded that site to a sub directory so he could see the evolution.
    He approved the design, yay!
    At the end of the process, he told me he needed to have full control with the editor. (style, images, bulleted list, need to put downloadable document like pdf etc.) i told him that he could only modify what was allready there with the Muse in Browser editing (that he saw when i made the pitch using another site) he was impress with the way it worked.
    so i told him i would have to remake "template".
    I thought of using a BC template, and modify the looks to adapt to my client image, Of course, use a responsive theme so he could make the change at one place only. (cos in Muse you need to make the changes on the 3 layouts).
    Now, i created a new temporary site using one of the new responsive template available.
    How can i import that new site onto his live domain? In other words, how can a switch from a theme made in Muse, to a BC template?
    cant i just delete everything in the root folder, and upload the entire new site via ftp?
    please help me find the solution. i am a bit in a panic here
    hope you could understand my lousy English.
    Sincerely,
    i.d.

    This would need to be transparent for m'y client...
    Y
    Envoyé de mon iPhone
    Le 2014-04-20 à 15:29, Sanjit_Das <[email protected]> a écrit :
    Re: help need to switch Muse site to BC on a allready hosted plan
    created by Sanjit_Das in Help with using Adobe Muse CC - View the full discussion
    Thanks for additional details.
    Unfortunately we cannot change site template of a live site in BC , but as a workaround Create a site from BC using the template you wish to use then publish the site from Muse to the site created from BC and transfer the contents stored from live site to trial site. Ater final transition is done , you can delete the already paid site and make live the new trial site which includes new site template.
    Thanks,
    Sanjit
    Please note that the Adobe Forums do not accept email attachments. If you want to embed a screen image in your message please visit the thread in the forum to embed the image at http://forums.adobe.com/message/6314730#6314730
    Replies to this message go to everyone subscribed to this thread, not directly to the person who posted the message. To post a reply, either reply to this email or visit the message page: http://forums.adobe.com/message/6314730#6314730
    To unsubscribe from this thread, please visit the message page at http://forums.adobe.com/message/6314730#6314730. In the Actions box on the right, click the Stop Email Notifications link.
    Start a new discussion in Help with using Adobe Muse CC at Adobe Community
    For more information about maintaining your forum email notifications please go to http://forums.adobe.com/thread/416458?tstart=0.

  • Catalyst 3560 24 port-PoE switch powers on but no STAT LED and console not responding

    I rebooted my Catalyst 3560 24 port PoE switch and when it turned on only the STAT LED went green the other LEDs are off.  I get no response from the console port using putty and the cable I used before this happened.  I tested the cable on another switch and it works fine with putty.  What can I do with this switch?

    This unit was purchased before I came to our company.  There is no support or maint contract.  I'm sure the unit is several years old...we'll call the vendor and see what they'll do..not expecting much.

  • What series of Cisco Switch I Need?

    Hello colleagues,
    I want to know which Industrial Series Switch I need to choose and meets the following minimum specifications.
    -at least 4 SFP ports 1Gigabit
    -at least 4 PoE port 100MB
    -IP20 or IP30
    I can use extra modules for to achieve the minimum technical specifications.
    I appreciate your time and hope you can help me.

    The IE 3010 only has two SFP ports. To get 4 SFP ports and the PoE copper ports you're asking about you would need the IE3000-4TC with one expansion module for PoE ports (IEM3000-4PC) and another for the additional fiber (IEM-3000-8FM). you would also need to add the separate power module for the PoE.
    Reference the product data sheet. they ar rated for IP20 or 21 per the hardware installation guide technical specifications.

  • Problem in connecting ESW 520 POE switches

    Hi
    New on ESW 520 switches
    Need help to configure the ESW 520  24 POE switches
    How can i configure the last port of 24 to oonnect to another ESW 520 24 port switches ?

    Why not use the GE ports at the far right to chain the switches one to the other from the UC540/UC560?  They are best for this and gives you an extra port on the switch this way.  Use straight thru ethernet cables.

  • Linksys Cisco SRW248G4P 48-port 10/100 + 4-port Gigabit Switch Help

    The switch which is a Linksys Cisco SRW248G4P 48-port 10/100 + 4-port Gigabit Switch, was configured by a contractor which was long ago run off, and the documentation left behind to log into the switch is incorrect. How can we reset this switch so we can configure to the new required settings?
    I have attempted to go in through the web browser gui, and no luck logging in via factory default creditials, cannot log in using any of the common admin creditials, nor can we get in via the documented admin name and pw the contractor left.
    Attempted ot go in through the console, that doesn't work right at all. Takes 15-20 min before I start even seeing user name or password boxes.  Cannot type a single thing into those boxes.  I have set the hyperterminal to com1,  38400, 8, none, 1, hardware.  It kinda lets me see some of the log in screen, but will not let me type into the username whatsoever.
    Logging via web browser I see all the login option but not a single username or pw works. Please if anyone can help, this has been an issue which is now critical.

    Hi, My name is Eric Moyers. I am a Network Support Engineer in the Cisco Small Business Support Center.
    The settings for connection using Hyperterminal through the Console port should be:
    Bits per second: 38400
    Databits: 8
    Pairity: None
    Stop bits: 1
    Flow Control: None
    When you finish configuring the HyperTerminal, the Login screen appears. The first time you open the Console Interface, use the default username admin and leave the password blank and press the Enter key. You can set a password later from the User and Password Settings screen.The Main Menu screen displays six menu choices: System Configuration Menu, Port Status, Port Configuration, PoE Configuration, Help, and Log Out.
    User and Password Settings, IP Configuration, File Management, Restore System Default Settings, Reboot System and Back to Main Menu.
    To restore the Switch back to the factory default settings, select Restore System Default Setting and press Enter. A confirmation message appears asking Are you sure? [Y/N]. Press the Y key to continue or the N key to cancel the action.
    System Configuration Menu options: (Which is where you will need to go) consist of: System Configuration, Management Settings
    After pressing Y, at this point reboot your system and it will be back to Factory Fresh.
    If you have any questions or this doesn't work, please let me know. I am attachng the Admin Guide for you as well.
    Eric Moyers
    Cisco Support Network Engineer
    1-866-606-1866

  • VLAN's, subinterface, access-lists and 3560 catalyst switch?

    Hi,
    How can I isolate VLAN 121 from all others?
    I have a cisco 2811 router connected to a 3560 catalyst switch which has 5 VLAN's of which I need to protect IP traffic of 4 from 1.
    The following VLANs configured on the switch:
    VLAN 0 192.168.132.0 /24
    VLAN 135 ..135.0 /24
    VLAN 137 ..137.0 /24
    VLAN 139 ..139.0.24 and lastly,
    VLAN 121 192.168.121.0 /24 which I wish to isolate all IP from VLAN 0, 135, 137, and 139 but have internet out the 2811's other interface. Currently all VLAN's and routing are working perfectly.
    I need some advice please. Here is my plan:  to split the FA0/0 into FA0/0.1 for VLAN 121 using dot1q and apply an access-list to deny 192.168.121.0 to the FA0/0 interface. Since I'm essentially creating VLAN's with the router can or will that interfere with the Switch VLAN configuration? router on a stick vs. a Layer 4 Cisco 3560 Catalyst switch?
    Thank you!

    I will have to assume VLAN 0 is the native VLAN / default interface on the router?  All VLANs are numbered native or not.  Just ensure the VLAN numbering matches between the router and the trunking on the switch.
    Yes, you could create a sub interface on the 2811 and use the router to route the VLAN.  Apply an access list on the other interfaces to block access to the VLAN you want to protect.  If you have routing enabled on the 3560 as well you would complicate the situation a bit more. 
    Please rate helpful posts! :-)

  • Help needed with Vista 64 Ultimate

    "Help needed with Vista 64 UltimateI I need some help in getting XFI Dolby digital to work
    Okay so i went out and I bought a yamaha 630BL reciever, a digital coaxial s/pdif, and a 3.5mm phono plug to fit perfectly to my XFI Extreme Music
    -The audio plays fine and reports as a PCM stream when I play it normally, but I can't get dolby digital or DTS to enable for some reason eventhough I bought the DDL & DTS Connect Pack for $4.72
    When I click dolby digital li've in DDL it jumps back up to off and has this [The operation was unsuccessful. Please try again or reinstall the application].
    Message Edited by Fuzion64 on 03-06-2009 05:33 AMS/PDIF I/O was enabled under speakers in control panel/sound, but S/PDIF Out function was totally disabled
    once I set this to enabled Dolby and DTS went acti've.
    I also have a question on 5. and Vista 64
    -When I game I normally use headphones in game mode or 2. with my headphones, the reason for this is if I set it on 5. I get sounds coming out of all of the wrong channels.
    Now when I watch movies or listen to music I switch to 5. sound in entertainment mode, but to make this work properly I have to open CMSS-3D. I then change it from xpand to stereo and put the slider at even center for 50%. If I use the default xpand mode the audio is way off coming out of all of the wrong channels.
    How do I make 5. render properly on vista

    We ended up getting iTunes cleanly uninstalled and were able to re-install without issue.  All is now mostly well.
    Peace...

Maybe you are looking for

  • Can't boot on my external hard drive on another Mac (stop sign)

    Hi, My system is placed on an external SSD connected to my iMac. I've just bought a brand new Mac Mini and I wish to boot it using my SSD. When I pick it up in the startup alternatives list (maintening the "Alt" key pressed during the boot), I just g

  • Problem with ejb 3.0 entity beans with manyToMany relationship

    Hello everyone! I am using struts 1.2.9 and java ee 5 sdk update 2 for my enterprise application. Besides others i have these entity beans Targetgroup.java and City.java, (i would upload file but i do not know how:) with manytomany relationship with

  • Case-Insensitive Servlet Headers

    Hi All, i have a problem with JDK 1.5 servlet package. i am getting case-insensitive header names when i call the request.getHeaderNames() method. When i send "Test" header name i am getting "test" is it a bug with this servlet version or is there a

  • Inventory Management (0IC_C03) Business Content queries

    I have the following queries which are delivered when I activate 0IC_C03.  The queries below have also been activated as part of the model. Is there any additional queries which should/can be activated against this InfoProvider and of the list below

  • Upgrading software

    I am trying to upgrade FCP which requires an update of Quicktime. Every time I try to upgrade Quicktime through Software Update I get an error message stating that I don't have sufficient permission. I am the only user and my account has administrati