4.6 C to ECC 6.0 Upgrade Project Timeline Sheet in MPP format

Dear all,
We are now proposing our customer for the 4.6c to ECC 6.0 Upgrade.
Our customer is currently in 4.6c/oracle 9i/HPUX 11 i. He wants to move to ECC 6.0.
If you have the project timeline for the above Technical Upgrade, can you pl send it to me.
If you don't have in MPP format atleast send me the Work Breakdown structure with timelines.
I shall modity the same to our customer and submit
Thanks & Regards
Senthil
[email protected]

Preparation Phase* 6 days
Kick Off Meeting 1 day
Upgrade Project Procedures Preparation 1 day
Prepare Upgrade Project Plan 1 day
Technical Requirements Assessment 3 days
Assess Training needs of Key-users & End-users 1 day
Prepare Detailed Basis Activity List for DEV, QA & PRD 1 day
Business Blueprint Phase 6 days
Develop System Landscape Upgrade Plan 1 day
Functional Requirement Checklist 1 day
ABAP Development check list 1 day
Develop detailed Training Procedures & Documentation for Key Users & End Users 1 day
Identify Testing Scope & Scenarios 1 day
Identify Authorizations Conversion to Roles for SAP ECC 6.0 2 days
Develop Documents as per Basis Activity List 1 day
Develop Authorization Matrix for Activity Groups to Roles Conversion 2 days
Prepare Upgrade Deliverables Checklist 1 day
Realization Phase 28 days
Installation of Solution Manager 3.2 System 1 day
Creation of New Development System for Upgrade Project (Homogenous System Copy - PRD) 2 days
Upgrade to AIX & Oracle 10g, SAP ECC 6.0 on New Development Server 3 days
Upgrade Frontend Software 4 days
Perform SPAU & SPDD Corrections 5 days
Perform ABAP Development & Corrections 10 days Perform Authorizations Conversions and corrections after upgrade 8 days
Perform Upgrade Testing for each Application Module 7 days
Perform Unit & Integration Testing 6 days
Perform Training to Key Users & End Users (Generic & Specific) 3 days
Upgrade to AIX, Oracle 10g, SAP ECC 6.0 on Quality System 1 day
Homogenous System Copy of PRD to New Quality & Upgrade to AIX, Oracle 10g & SAP ECC 6.0 2 days Perform Testing in Quality System 3 days
Testing by end users on Quality System 1 day
Production Realization & Go-Live Phase 6 days
Upgrade to Production System Operating System to AIX (after close of business hours - 23:00) 1 day
Oracle Upgrade to 10g (after close of business hours - 23:00) 1 day
SAP Release Upgrade to ECC 6.0(Downtime Minimized - Downtime occurs in non-business hours) 2 days
User Acceptance Testing 1 day
Production System Go-Live 1 day
Post Go-Live Support 14 days
Post Go-Live Support 14 days Note: This is high level plan subject to change during Business Blue Print Phase 0 days
This is taken from a post in Ittoolbox, May be this is generic. Hope you can tailor this to meet your requirements.

Similar Messages

  • New Development project  in the middle of  ECC EHP7 upgrade project

    Hi All,
    We are performing ECC EHP7 upgrade project in our project system landscape and i have already started Dev system upgrade.Suddenly our development team wants to perform new project  which required to install add-on product from third party application. Installing new add-on will require us to regenerate stack.xml file right? if that is the case  do we need to perform re upgrade to Dev right?. As per my knowledge this is not recommended to perform parallel project with upgrade project.
    Is there any  best practice or recommended method to perform multiple projects with upgrade project at the same time.
    Thanks,
    Raghu

    Hi Raghu,
    First here i would like to suggest you & your development team i.e during an upgrade project dual maintenance is required as per SUM guide,as per SUM guide you need to maintain parallel systems to perform regular activities, for same you could refer SUM guides and follow the standard procedures.
    Installing new add-on will require us to regenerate stack.xml file right?
    Yes you need to regenerate the stack.xml file .
    if that is the case  do we need to perform re upgrade to Dev right?
    If you are under upgrade phase no need to perform re upgrade,required add on can be installed after completion of an upgrade as per availability for EHP7.
    Try to avoid perform multiple projects with upgrade project .
    Regards,
    Gaurav

  • Screens not working in ECC 6 after upgradation from 4.6c.

    Hi,
    The custom developed screens which where developed in 4.6c version is not working properly in ECC 6 after upgradation.Do i have to make any more changes for this .? If anyone have an idea please help me in this issue.The custom developed things are an extended functionality we have done to r/3.
    Regards,
    jinesh kumar c.

    Hi,
    Check the Transportatation Logs in STMS for the programs/screens and check whether they are successfully tranported or not?
    Because some times we get Dynpro errors for transportation of the screens.
    Reward if useful.
    regards,
    Anji

  • IM (Inventory material) is failing in ECC 6.0 upgrade from SAP R/3 4.7

    Hello,
    We are working on Technical upgrade project (SAP R/3 4.7 to ECC 6.0 EHP 6) for one of our Client.
    when we are trying to create a purchase order (ME21N) in upgraded system (ECC 6.0), the field  IM Material is failing to accept the internal material values from MATNR field. After entering the IM material, the value immediately got disappeared and it needs some workaround to get the material back in to the IM field along with MPN material.
    It was working fine (accepting Internal material) in R/3 4.7, if we give a valid internal material, it immediately get copies to the field IM Material.
    In case of ECC 6.0, it is completely failing.
    Please suggest if you have come across any solution?
    Regards
    Rifaie

    Hi Selvan,
    Go through document in below thread,you will get more info on upgrade
    https://www.sdn.sap.com/irj/scn/wiki?path=/display/erp6/sapERP6.0+Upgrade%2520%2520SAP%2520ERP%25206.0%2520Upgrade
    Faq's on SAP upgrade in below link,
    SAP ERP 6.0 Upgrade
    Thanks Regards,
    Syfulla

  • SAP R/3 4.6 C to ECC 6.0 Upgrade using CU &UC method- Unicode conversion

    Basis Gurus
       I am working on upgrade from R/3 4.6C to ECC 6.0.
    ECC 6.0 upgrade completed( still in non Unicode).  Now I am in the process of Unicode conversion.
    I have used following methods for the upgrade.
    1. Combined Upgrade & Unicode conversion(CU & UC)
    2. Resource minimized( as I am doing it in Sandbox).
      As I understand I need to perform the DB export and Import now for the unicode conversion.
      According to the Upgrade document, First I need to run Export using R3load in ECC6.0(Non unicode)
      and then install Unicode system and import the same data file.
      My understanding was, when I choose, Resource minimized, I need to run Export and import
      in the same system.
      Can you please help me , whether I need another Unicode system for import ??
    Graham

    Hi,
    Dont get confused with upg strategy and unicode conversion.
    In general Upgrade strategy (either downtime-minimized/resource minimized)
    In unicode conversion you have export/import(exp/imp) of data concept
    In CU&UC approach you have to do in a streach to complete migrate from old release to new realease ECC 6.00.
    Using database independent (sapinst only) or Using database dependent (migration monitor or Distribution monitor)
    It can be done in 2 ways.
    If you dont have addtional server for unicode conversion
           1)you can either do exp on same hardware and take bakup and do import using the exp dump.
           2)Do exp on one server and prepare your target empty database on another server and complete imp of data.
    Hope this is clear.
    Regards,
    Vamshi.

  • ECC-600 EHP4 upgrade with VIRSAHR 520 700 - PREP_EXTENSION/ADDON_QCALC

    Hi
    We are getting following error at phase PREP_EXTENSION/ADDON_QCALC in the ECC 6.0 upgrade:
    3 ETN256 You want to install the following add-on components:
    3 ETN248 Component: "VIRSAHR" rel. "520_700", Support Package
    level: "0" (component type "A")
    3 ETN248 Component: "VIRSANH" rel. "520_700", Support Package
    level: "0" (component type "A")
    2 ETN085X"2. Adding Add-on Installation Queue" " " " " " "
    3 ETN262 Calculating queue part for add-on "VIRSAHR" rel. "520_700"
    3 ETN490 Use the Add-On installation package "SAPK-523EXINVIRSAHR"
    (type &4"AOX") for Add-On &2"VIRSAHR" rel.&3"520_700"
    3 ETN245 The following import prerequisites of OCS Package "SAPK-
    523EXINVIRSAHR" have not been met:
    3 ETN264 In the (alternatively) Requirement set "01":
    3WETN491 Required software component "SAP_HR" rel."600" is not installed2WETN543 OCS package "SAPK-523EXINVIRSAHR" does not match the current
    software component vector
    1 ETN214X."**************************************************"
    We have alreacy checked note 1002147, which clearly states that we have to include SAPK-523EXINVIRSAHR in the upgrade. SAP_HR is part of the upgrade.
    We have included SAP_HR and other Support Package as per the queue generated by Solution Manager, but we did not include VIRSAHR & VIRSANH Packages until we got to this phase. We then included these support packages in eps\in directory, but we are now getting this error now.
    Any ideas?
    Regards
    Chandu

    Hi
    This is what the solution provided by SAP Support:
    Quote:
    we have finally found the problem, it's a bug in the package upload
    functionality used by the upgrade. The consequence of this bug is that
    Support Packages whose EPS files (.PAT files) have a certain string in
    the name, namely the string 0000000 after the _ and before .PAT
    extension, are not properly uploaded to the ABAP system and hence are
    not visible or known to the upgrade.
    This bug will be fixed in the next upgrade tool fix, but in the meantimeyou can use the following workaround:
    Check your EPS/in directory after the CAR/SAR Archives of the SPs are
    extracted and rename all .PAT and .ATT files, which have a name like
    *_0000000.PAT (or *_0000000.ATT), by changing the string 0000000 to
    9000000. For example, for the VIRSANH SP SAPK-52302INVIRSANH rename the
    file VS30020106486_0000000.PAT to VS30020106486_9000000.PAT
    Afterwards, the upgrade will upload the informations about the SP
    properly and the SP can be included into the upgrade.
    Files:
    31/01/2007 07:32 329 VS30020106486_0000000.ATT
    31/01/2007 07:32 554,073 VS30020106486_0000000.PAT
    If these two files are renamed to e.g.
    VS30020106486_9000000.ATT
    VS30020106486_9000000.PAT
    the affected VIRSANH SP2 is uploaded correctly by the upgrade
    functionality and the SP inclusion of the VIRSANH SPs works.
    Sorry, as of now I cannot promise you a date when the tool fix will be
    available. I have found this bug only today in the evening (german time)and will discuss this with the responsible colleagues tomorrow.
    Afterwards, I will know more...
    Unquote:
    Hope this helps. We have decided against upgrading to 530_700 as it will involve upgrading GRC system and also new version has lot of new functionalities, which we like explore it after the ECC upgrade.
    Also, I would not suggest deleting VIRSAHR as all the config and customising done for VIRSAHR will be lost.
    Regards
    Chandu
    Edited by: Chandu Cheeti on Jan 17, 2010 11:19 AM

  • Error in WBS Element Hierarchy load after ECC 6.0 Upgrade

    Hi All,
    After ECC 6.0 Upgrade in R/3, we are doing test load in a Test server. While doing, we have encountered an issue with 0WBS_ELEMENT Hierarchy load. The message in the monitor is like below.
    "Node ID 00014240 has not been included in the hierarchy
    Message no. RH207"
    When I run the same hierarchy in another system which is not upgraded , it works fine.
    Anybody has faced similar kind of issues and can throw some light on this issue?
    Thanks,
    Mohan

    Try activating the Heirarchy in R/3 and re-trigger the load, error is very specific to structure of the hierarchy. there is a possibility that this Hierarcy could have got inconsistent after the upgrade.
    Thanks,
    Amit

  • 4.6C to ECC 6.0 Upgrade Transaction codes?

    I am involved in an upgrade.  I have a list of t-codes used on 4.6C.  I want to compare these t-codes with ECC 6.0 and find out which ones are gone and the ones that have changed.
    Is there any easy way or any one document that can help me acheive this?  I would appreciate the input from the experts here.  Will award points to any help provided.

    In my previous project 4.6C to ECC 6.0, which was a technical upgrade, we have done it manually, here is what we followed:
    1) In Unit Level T-Code testing, in technical upgrade, you are only expected to check the working of T-Codes in ECC 6.0 compared to 4.6C, this is on DEV server, with available data. Just execute the T-Code.YOU WILL KNOW WHICH T-CODE IS IN AND WHICH IS OUT(RARELY) IN DURING THIS ACTIVITY. SCOPE REMAINS THE TCODES USED BY YOUR CUSTOMER.
    2) In Integration Level Testing, User Acceptance Testing and Critical Transactions Testing in technical upgrade, you need to test the scenarios with a copy of production data on QAS server.
    Now, the comparision of the T-Codes can be -
    1) Functionallity point of view (refer link provided by Naveen)
    2) GUI
    In Technical Upgrades the focus remains on GUI only. Hence the comparision is done manually between from 4.6C and ECC 6.0. The scope should always remain the Test scripts signed off by customer. The reason is that the user's need to get trained on the changes in GUI for which we captured screen shots wrt 4.6C and ECC 6.0 wherever changes have been encountered within the scope of the test script steps.
    Was well received by the customer.
    Lastly, just focus on the approach to take to make things simpler for you.Check the context of your Upgrade Project and move accordingly.

  • How to process for an ECC 6.0 upgrade for different objects (RICEF)?

    Hi eaxperts,
    I am new to upgrad project. Can anyone pls. tell me in details things that need to be undertaken in an ECC upgrade project for different objects e.g. RICEF and How should I process for the same?
    Please also tell me the important T-codes for the same and how to use them.
    Thanks a lot in advance,
    Sandy

    Hi,
    Please read below lines.I think u can get some knowledge about UPGRADE.
    u2022     System preparation and stack level patch upgrade u2013 Basis Team
    First of all, the basis team installs the Latest SAP version on the hardware and they apply all the general patches up to the latest stack level. All the stack levels of various patches u2013 Basis, ABAP, XI etc should be brought up to the latest level by the basis team. In case, all the stack levels are not the latest, it might create problems like new objects coming into the SPAU during the upgrade or thereafter u2013 these will be explained in sections below.. So it is a good practice to get the system to the latest stack level.
    u2022     SPDD Phase u2013 ABAP and Functionals
    This transaction code SPDD is the core step in an upgrade project. The system compares all the dictionary objects u2013 data elements, database tables and structures of the latest system (say ECC) with the previous or the old system (Say 4.6c). These all elements are present under two nodes u2013 with modification assistant and without modification assistant. Objects present under with modification assistant have the modification assistant u2018ONu2019 and we can see the modification logs.
    u2022     Up gradation of the system u2013 Basis Team
    After the SPDD phase is complete, the basis team prepares the system for an UPGRADE u2013 i.e. the old system would be replaced by the new system. In this phase, the system asks for the SPDD request u2013 the single request which generates and activate all the dictionary objects present in SPDD phase in the new system u2013 ECC. If the request do not contains the same objects which were present in SPDD, the system shows a danger alarm u2013 stating that this SDPP request do not contains all the desired objects and it might make the system unstable. In case any other objects are missing, there and then it should be put in the SPDD request.
    u2022     SPAU Phase u2013 ABAP and Functionals
    The SPAU transaction contains the objects u2013 Programs, Reports, Screens, Messages, Notes, Function Modules etc. which have difference in the Latest SAP request and the previous ones. This SPAU phase can be done either just after SPDD or after the Up gradation of the system by the Basis team.

  • No blank first column in Excel after ECC 6.0 upgrade

    Hi,
    I am facing a weird issue. There was a recent upgrade to ECC 6.0, after the upgrade the excel sheets that are downloaded from SAP transaction COOIS do NOT have a blank first column.
    Is there a way to fix this issue, some external applications use this excel report to read the data and it is really difficult to fix all those applications. Please do let me know if you have any clue.

    Try activating the Heirarchy in R/3 and re-trigger the load, error is very specific to structure of the hierarchy. there is a possibility that this Hierarcy could have got inconsistent after the upgrade.
    Thanks,
    Amit

  • Issues in ECC 6.0 upgrade

    Hello,
    We are doing an upgrade from SAP 4.7 to ECC 6.0. In step 2C of SU25 we get a large number of roles in "RED". How do we identify if any additions or changes have happened to these roles. Please help
    Many thanks
    Vijaya

    Hello Vijayalakshmi,
    pls use the search function in this forum (for instance <SU25> returns 11 hits, for instance this one: https://forums.sdn.sap.com/click.jspa?searchID=13818484&messageID=5409652
    > How do we identify if any additions or changes have happened to these roles. Please help
    >
    Well, if the roles are listed in SU25/2c, then there have been changes to that roles. In normal cases the SU24 values for the contained transactions have been changed or the transactions themeselves got changed/removed/replaced.
    The documentation for SU25 is quite good and gives some valuable information too.
    I hope this gives you a starting point for your upgrade project.
    Last tipp: it is not a good ideay, to skip SU25 after the upgrade. Sooner or later you will have to perform this task to avoid losts of reclamations regarding missing authorizations from your users.
    b.rgds, Bernhard

  • Load balancing after ECC 6.0 upgrade

    Hi
    I we this configuration on ECC 6.0 upgrade:
    SAPGUI 7.10
    SAP_BASIS  700  Patch level 15
    SAPportal ESS
    Webdispatcher Installed
    Internal ITS
    Single sign-on
    Can somebody assist as with identifying the problem with load balancing (PUBLIC) E.g. When running ESS remuneration package via the Sapportal. we have configured ITS-Based GUI Services on transaction SICF for customised ZESS_PZ11PDF service.
    When we have load balancing group on the load balancing does not work, because  I  see somebodyu2019s payslip
    but when using one app server I see my own payslip. Please help.

    Hi PR,
    Please take a look at the following link:-
    http://help.sap.com/SAPHELP_NWPI71/helpdata/EN/28/75153a1a5b4c2de10000000a114084/frameset.htm
    "You can only use the SAP message server for HTTP load distribution if 
    the browser is the direct client of the message server. If another     
    component lies between the client (browser) and the message server, (for
    example, the portal), you cannot use the message server to distribute  
    the load."                                                             
    When using the External ITS you could balance the load using the message server and logon groups. In 700 this functionality is not present if there is not a direct connection to the client (Firefox or IE). So you will have to install the webdispatcher to balance the load.
    Hope this helps
    Michael

  • Upgrade Project - 4.7 to ECC 6.0

    Hello Gurus,
    I am HR Functional consultant and assigned to work on upgrade project (4.7 to ECC 6.0) for the first time. I am new to this environment. Can any one help me with suitable documents to start with. My mail id: [email protected]
    Points assured..
    Thanks in advance
    Regards
    kasi

    Dear kasi raj,
    For Functionality Differences pls refer to the below site -
    http://solutionbrowser.erp.sap.fmpmedia.com/
    After opening the site, please select the Source Release Version which is 4.6 b Then Select the Target Release Version which is "mySAP ERP 2005" or ECC 6.0
    Select the Solution Area like Financials, Human Capital Management, Sales....
    Select module like MM, PP, SD, QM.....
    Click on Search
    Then it displays the Release Version and the Delta Functionality. which can be downloaded to a word document if required.
    and also check the release notes of ECC 6.0 in service.sap.com.
    Hope this helps you.
    Do award points if you found them useful.
    Regards,
    Rakesh
    P.S. you can send me a mail at my mail id [email protected] for any specific details

  • Data transfer form 4.7 to ECC 6.0 in upgradation project. How to do?

    Hi Experts,
       The client is going for an up-gradation from 4.7 to ECC 6.0. The entire data needs to be transferred from 4.7 to ECC 6.0. What is the best possible way to do this?
    Please advise.
    Regards,
    Tomesh

    Hi ,
    Going for an up-gradation from 4.7 to ECC 6.0. The data needs gets migrated from 4.7 to ECC 6.0.
    SAP normally has defined better SAP functionalities in the new system .
    In any upgrade project use Tcode SPDD. In this all the dictionary objects u2013 data elements, database tables and structures in the version 4.7 are compared with the upcoming new system.
    All you need to do is the check whether the new change is suitable or not.You can make the modifications and then you need to make the migration of data, which can be automate.
    the links for your reference.
    Link:[https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/304b9de6-f84f-2b10-94af-e5ff7461c18c]
    link:[http://solutionbrowser.erp.sap.fmpmedia.com/Default.aspx]
    Thanks & Regards,
    link:[Lakshmi Narayana]

  • Hardware requariment for ECC 6.0 upgrade from ECC 5.0

    Hello
    I am on ECC 5.0 with oracle 9.2.0.7.I need to upgrade this to ECC 6.0.
    I have already implemented MM,PP,FICO,QM and HCM.My current data base size is 900GB.This has 30GB monthly growth.
    With this ECC 6.0 upgrade i am planing to implement PM,EP.
    I know converting none Unicode system to unicode system is required some more hardware resources than the none Unicode.
    Some document says 40-60% more disk space and 35% more processing speed from current system.
    Can any one give me the correct information about the hardware requirement for ECC 5.0 to ECC 6.0 upgrade.
    Thanks
    Roshantha

    Check with the Links
    https://websmp102.sap-ag.de/sizing
    https://websmp208.sap-ag.de/quicksizer
    http://www.4soi.de/
    http://www.easymarketplace.de/
    Kanagaraja L

Maybe you are looking for

  • FireFox browser does not show toolbar when login to infoview

    Hi, I am using Business Objects Enterprise XI release 2 with SP 4. When i login to infoview using FireFox I can not see the toolbars and menus needed to create a New Webi report or any other reports. Has anyone know how to fix this? I tried the follo

  • Output of Quicktime File from FCP 7 for iDVD

    I just finished a client project using FCP 7 and he seems to have issues doing the following (on a MacBook Pro): 1) Placing the file on the main hard drive 2) Importing to QuickTime, or iMovie, iDVD Ideally, my client would like to have the ability t

  • Multi-threading in Flash Builder 4.6

    Hello All, I am a new user of Flex and Flash Builder 4.6. Is there any built-in mechanism that allows to implement multi-threading in Flex/Flash Builder 4.6? I have done a little research via the Internet regarding this issue, and I understand that t

  • Elements 12 - how to save camera raw edits as .jpeg and not .DNG

    Just bought Elements 12, previously used CS5.  I only use Camera Raw to edit pics.  In CS5, I can save my edited photo as a JPEG.  In this new Elements 12, the only option is to save it as a .DNG file.  I figured out that if I open the file in Elemen

  • Jquery ui widgets

    Where can I find some videos on using the jquery widgets that are in dreamweaver.  I want to see what the possibilities are.  I am not sure if I can download more plugins to give me more options within dreamweaver or if i need to download stuff that