I have (2) Cisco 4500x with a VSS config. I als have a couple cables "SFP-H10GB-CU1M".
I want to make sure I have this physically setup correctly. I have searched but not found anything specific enough.
Please review and advise.
Yes, all device packages are installed (including 7.0) and the Pi 2.1.2 patch.
Info from "ifm_config_archive.log" when trying Archive the Configuration:
[2014-12-09 19:58:11,300] [pool-37-thread-5] [service] [ERROR] - Thread Id : [9,460] : IFM_CONFIG_ARCHIVE_ERROR_DETAILS: [Error in fetching VLAN file] : IFM_CONFIG_ARCHIVE_ERROR: [com.cisco.ifm.config.archive.service.exceptions.XDEFeatureExecutionException: No device package found for the specified device.]'
Maybe the Prime don't know where to find the vlan.dat on the 4500X-VSS ?
#dir cat4000_flash:
Directory of cat4000_flash:/
1 -rw- 2236 <no date> vlan.dat
sysObjectID (1.3.6.1.2.1.1.2) is
.iso.org.dod.internet.private.enterprises.cisco.ciscoProducts.cat4xxxVirtualSwitch
That is not the expected and supported value "4500X-16" above
Update: Error on fetching running and startup config as well:
[2014-12-09 20:24:21,818] [pool-37-thread-9] [service] [ERROR] - Thread Id : [10,013] : IFM_CONFIG_ARCHIVE_ERROR_DETAILS: [Error in fetching RUNNINGCONFIG file] : IFM_CONFIG_ARCHIVE_ERROR: [com.cisco.ifm.config.archive.service.exceptions.XDEFeatureExecutionException: No device package found for the specified device.]
[2014-12-09 20:25:31,882] [pool-37-thread-9] [service] [ERROR] - Thread Id : [10,013] : IFM_CONFIG_ARCHIVE_ERROR_DETAILS: [Error in fetching STARTUPCONFIG file] : IFM_CONFIG_ARCHIVE_ERROR: [com.cisco.ifm.config.archive.service.exceptions.XDEFeatureExecutionException: No device package found for the specified device.]
Similar Messages
-
SFP-H10GB-CU1M SFP+ Copper Cable module speed shows as Unknown
I have connected 2 SG500x switches using an SFP-H10GB-CU1M SFP+ Copper Cable module. Since the port shows as a 10G port, I would expect the speed to show as 10G as well. However, it shows as "Unknown". This doesn't leave me with confidence that it is being recognized properly. The link is working properly, but I haven't run tests to verify if I'm getting full 10G throughput or not. I'll work on that. In the meantime, anyone have any ideas as to the proper behavior here? Shouldn't it show 10G as the link speed?
Hi Robert,
I love the GUI, so easy to navigate, when you get the feel for the layout of the switch options. So going to ask you to use the GUI to find the stacking status and speed between the switches..
Step 1. Select help at the top right of the GUI screen,
Step 2. Type in as a search option "stack speed " then clock go
see my screen capture below,.
( The switch has basically an Administration guide built in., a really cool cool feature )
So you see the following screen capture that shows the option that I selected;
Followed the instruction outlines in the online help text, the following screen capture shows me the stacking speed.,
I have two by SG500-52P, my SG500X are loaned out to a partner to evaluate, so i can only run 5G over the SFP-H10GB-CU1M stacking module on this platform.
Hope this helps you clarify where to find stack module speed.
regards Dave
Rate this post -
Compatibility between ASR9K and SFP-H10GB-ACU10M
Hi Everyone,
I have in my environment two ASR9K with module A9K-16T/8-B and I am trying to connect using the Active Twinax cable 10M (SFP-H10GB-ACU10M), however when I connected the cable, shows the following error:
State:
Administrative state: enabled
Operational state: Down (Reason: Security failure (not a valid part))
LED state: Red On
Phy:
Media type: Not known
Optics:
Vendor: CISCO-TYCO
Part number: 2163675-2
Serial number: TED1618U0H0
I checked the compatibility list and apparently okay, as shown in the link below:
http://www.cisco.com/c/en/us/products/collateral/routers/asr-9000-series-aggregation-services-routers/data_sheet_c78-624747.html
Please, the community can help me?
Best Regards,
Vitor NakanoThe twinax copper 10 Gig SFPs such as the one you cite are prefabricated cables with transceivers already attached. See the pictures on the top left of the data sheet to visualize what you get.
Controlling that mating of transceiver to the copper media is how they are able to ensure reliable operation at 10 Gbps over copper. -
The cisco nexus interface is only detecting the type as
SFP-H10GB-CU1M, instead of SFP-H10GB-ACU7M. Is the PROSFP transceiver and cable supported by Cisco's Nexus? Is this a supported connection?
Thanks.... -
N5K:does active Twinax SFP-H10GB-ACU7M support FCoE
Hi
does SFP-H10GB-ACU7M and SFP-H10GB-ACU10M support FCoE if they are used in Nexus5000 running 5.0.3
I heard rumors thats it could be that these active Twinax do not support FCoe because they could net reach the BER which is necessary for FCoE
KR
HubertHubert,
They're in the compatibility matrix but only show being supported by NX-OS 4.2(1)N2(1)
http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6974.html
I don't know about the Bit Error Rate though. The fact that they're supported in 4.2.1 but not in 5.x makes me think its a testing thing rather than a functional BER thing. I could be wrong on that though. Short answer is not supported.
--Justin -
Cat6807 + VS-S2T-10G + CVR-X2-SFP10G + SFP-H10GB-CU5M?
Is the Cisco OneXConverter Module, CVR-X2-SFP10G, compatible with VS-S2T-10G in a 6807 using a SFP-H10GB-CU5M cable to connect to an ASA5585?
Description of the CVR-X2-SFP10G, which states it is compatible with the SFP-H10GB-CU5M:
http://www.cisco.com/en/US/prod/collateral/modules/ps5455/data_sheet_c78-547521.html
Compatibility matrix which eludes the CVR-X2-SFP10G module is compatible with the VS-S2T-10G and SFP-H10GB-CU5M but only if the SFP-H10GB-CU5M is version 2. I am not comfortable with this chart as it does not list the software requirement which could imply it is not compatible when used with the SFP-H10GB-CU5M.
http://www.cisco.com/en/US/partner/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6974.html
snippit of chart:
Platform
Switch or Module
Transceiver Model
Minimum Software Release Required
VS-S2T-10G
VS-S2T-10G-XL
WS-X6816-10G-2T
WS-X6816-10G-2TXL
WS-X6908-10G-2T
WS-X6908-10G-2TXL
(With CVR-X2-SFP10G converter for X2 ports)
SFP-H10GB-CU1M1
SFP-H10GB-CU3M1
SFP-H10GB-CU5M1
SFP-10G-SR
SFP-10G-LRM
SFP-10G-LR
12.2(50)SY
12.2(50)SY
1 Only Version -02 or later is supported.Hello teater,
SFP-H10GB-CU5M1 is supported with Sup2T and CVR-X2-SFP10G starting 12.2(50)SY.
I will look into fixing the compatibility matrix to fill this missing cell.
Thanks,
~Amer -
Prime 2.1 and 4500X-VSS support?
Anyone with a Prime 2.1.2 that successfully archives configurations from a WS-C4500X-16 running VSS?
Error message after Configuration Archive:
No device package found for the specified device.
The software on the 4500X is 03.04.03SG.
Support for 4500X in PI 2.1.2:
Device Type
SYSOIDS
S/W Version
Software
Cisco Catalyst 4500X-16 SFP+ Switch
OID:1.3.6.1.4.1.9.1.1605
IOS
Cisco Catalyst 4500X-32 SFP+ Switch
OID:1.3.6.1.4.1.9.1.1606
IOS
TanksYes, all device packages are installed (including 7.0) and the Pi 2.1.2 patch.
Info from "ifm_config_archive.log" when trying Archive the Configuration:
[2014-12-09 19:58:11,300] [pool-37-thread-5] [service] [ERROR] - Thread Id : [9,460] : IFM_CONFIG_ARCHIVE_ERROR_DETAILS: [Error in fetching VLAN file] : IFM_CONFIG_ARCHIVE_ERROR: [com.cisco.ifm.config.archive.service.exceptions.XDEFeatureExecutionException: No device package found for the specified device.]'
Maybe the Prime don't know where to find the vlan.dat on the 4500X-VSS ?
#dir cat4000_flash:
Directory of cat4000_flash:/
1 -rw- 2236 <no date> vlan.dat
sysObjectID (1.3.6.1.2.1.1.2) is
.iso.org.dod.internet.private.enterprises.cisco.ciscoProducts.cat4xxxVirtualSwitch
That is not the expected and supported value "4500X-16" above
Update: Error on fetching running and startup config as well:
[2014-12-09 20:24:21,818] [pool-37-thread-9] [service] [ERROR] - Thread Id : [10,013] : IFM_CONFIG_ARCHIVE_ERROR_DETAILS: [Error in fetching RUNNINGCONFIG file] : IFM_CONFIG_ARCHIVE_ERROR: [com.cisco.ifm.config.archive.service.exceptions.XDEFeatureExecutionException: No device package found for the specified device.]
[2014-12-09 20:25:31,882] [pool-37-thread-9] [service] [ERROR] - Thread Id : [10,013] : IFM_CONFIG_ARCHIVE_ERROR_DETAILS: [Error in fetching STARTUPCONFIG file] : IFM_CONFIG_ARCHIVE_ERROR: [com.cisco.ifm.config.archive.service.exceptions.XDEFeatureExecutionException: No device package found for the specified device.] -
Hello,
Can anyone confirm that SFP-H10GB-CU5M can work with HP NICs (HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter, or modifications on same chipset) ?Hello teater,
SFP-H10GB-CU5M1 is supported with Sup2T and CVR-X2-SFP10G starting 12.2(50)SY.
I will look into fixing the compatibility matrix to fill this missing cell.
Thanks,
~Amer -
Cisco 4500X VSS & MEC Cisco 2960X
Hi
I have Cisco 4500x VSS connect to MEC Cisco 2960X using LACP.
I encountered a problem about C2960X
Integration reason
1.C2960X Ten 1/0/2 link flapping interface error-disable . I am disable interface then enable interface , switch show SFP not Present .
Te1/0/2 notconnect 1 full 10G Not Present. (SPF plug-in Correct)
2.use CLI reload C2960X , Ten 1/0/1 ,Ten 1/0/2 notconnect SPF Not Present. (SPF plug-in Correct)
error message :
Dec 18 12:40:25.250: %SYS-5-CONFIG_I: Configured from console by console
Dec 18 12:41:48.888: % ILET-1-AUTHENTICATION_FAIL: This Switch may not have been manufactured by Cisco or with Cisco's authorization. This product may contain software that was copied in violation of Cisco's license terms. If your use of this product is the cause of a support issue, Cisco may deny operation of the product, support under your warranty or under a Cisco technical support program such as Smartnet. Please contact Cisco's Technical Assistance Center for more information.
26F_guest_switch#show license
Index 1 Feature: lanlite
Period left: 0 minute 0 second
Index 2 Feature: lanbase
Period left: Life time
License Type: Permanent
License State: Active, In Use
License Priority: Medium
License Count: Non-Counted
3.C2960X power Cycle ,C2960X operation normal, ,but recurring problems every day.
I do not know where the problem , I have upgrade C2960X IOS but it had same problem.
Cisco 2960X IOS version: 15.2(3)E C2960X-UNIVERSALK9-M
Cisco 4500X IOS version: cat4500e-universalk9.SPA.03.05.00.E.152-1.E.bin
Thanks for your help,Hi Reza,
Thanks for your help
I can not confirm that because I have a few switch have the same problem.
C2960X 10G port 1 is connected to C4500X slot 1, Port 2 is connected to C4500X Slot2.
link flapping, On the switch port 2.
I need to do a more precise test to confirm the problem is C2960X or 4500VSS -
Dear All,
does SFP-H10GB-ACU10M come with SFP+ connectors?
or it is just a cable and we need to provide the SFP+ Transceivers??
thanksThe twinax copper 10 Gig SFPs such as the one you cite are prefabricated cables with transceivers already attached. See the pictures on the top left of the data sheet to visualize what you get.
Controlling that mating of transceiver to the copper media is how they are able to ensure reliable operation at 10 Gbps over copper. -
Hi,
I am having a major headache with RME collecting the vlan.dat from a VSS and 4510, the device and credentials work fine, however when archiving the config i get partial success due to vlan failing. You can see in the IC_Services log that it attempts to TFTP the .dat file off which it fails with, i believe vlan fetch is only supported by SSH or telnet
when you do a CDA test both devices pass on everything..managed to log on and please see below, tftp on one device works fine but from the 4510 or vss still fails
GRA_CHUB_CR_01#copy cat4000_flash: tftp:
Source filename []? vlan.dat
Address or name of remote host []? 172.20.220.10
Destination filename [vlan.dat]?
%Error opening tftp://172.20.220.10/vlan.dat (Timed out)
GRA_CHUB_CR_01#
DAR_R002_AS_01#
DAR_R002_AS_01#copy flash:vlan.dat tftp:
Address or name of remote host []? 172.20.220.10
Destination filename [vlan.dat]?
616 bytes copied in 0.009 secs (68444 bytes/sec)
DAR_R002_AS_01# -
What are the differences between Easy VSS and Traditional VSS on Catalyst 4500E with Sup 8E ?
I would like to know which feature is different between Easy VSS and Traditional VSS.
I know "Easy VSS is a new way of implementing VSS by using a single command" but I cannot find more information about it.
Please help.
Thank you.
NashEasy VSS is a simplified and automated way of configuring VSS for first time. Once a VSS is configured then it same as traditional VSS in functionality.
There is no concept of layer 2 or layer 3 VSL link. VSL is the internal portchannel link and you cannot configure as layer 2 or layer 3 portchannel.
Following is the link of Easy VSS steps.
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/XE3-6-0E/15-22E/configuration/guide/xe-360-config/vss.html#60764 -
How to show module and SFP information include hardware serial number on Nexus switch?
How to show module and SFP information include hardware serial number on Nexus switch? Thanks.
Hi,
The show inventory command will give you details of the Nexus chassis, power supplies, Supervisor, Fabric, I/O modules (including FEX if you have them) etc. To get the details of the installed SFP/SFP+ then you'll need to use the show interface transceiver command.
Regards -
Basic questation about VSS and windows backup
hi all, basic questation about backup and VSS
Environment:
windows 2008r2,NAS backup disk connected with iSCSI
If i create in the windows backup server job , where i backup disk D , target is NAS disk and start it . Windows backup is requester and is created shadow copy . This shadow copy is created in the disk D or in the NAS disk ? If in the disk D is created for
everyone application snapshot ? After created snapshot the windows backup copy data from snapshot to windowsimagebackup ? And If windows backup create different snapshot how detect which files is changed ?
thank you
FalconHi,
Windows Server Backup stores backup versions in volume shadow copies. After the data write is complete, Windows Server Backup creates a shadow copy of the volume where the backup is stored using Volume Shadow Copy Service (VSS). This shadow copy retains the
state of the storage volume as a “backup version” or “point-in-time” of the backup and must restore using this backup version.
You could refer to the article below to know the steps of a back up operation performs:
Backup Version and Space Management in Windows Server Backup
http://blogs.technet.com/b/filecab/archive/2009/06/22/backup-version-and-space-management-in-windows-server-backup.aspx
Windows Server Backup uses Volume Shadow Copy Service (VSS) and block-level backup technology to back up and recover your operating system, files and folders, and volumes. The Volume Shadow Copy Service is used to differentiate between backup sets, and to track
where the various blocks are being written to within the shadow copy storage.
For more information about the incremental backup technology, please see:
Learn more about system image backup
http://blogs.technet.com/b/filecab/archive/2009/10/31/learn-more-about-system-image-backup.aspx
Backup and Recovery Issues with Windows Server 2008 (Part 2)
http://www.windowsnetworking.com/articles-tutorials/windows-server-2008/Backup-Recovery-Issues-Windows-Server-2008-Part2.html
Please Note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
Best Regards,
Mandy
We
are trying to better understand customer views on social support experience, so your participation in this
interview project would be greatly appreciated if you have time.
Thanks for helping make community forums a great place. -
Hi !
We have 2 Infoblox in HA connect to a VSS and we recibe this log:
[2013/01/10 17:47:03.945] (24443 /infoblox/one/bin/clusterd) vrrp.c:1180 vrrp_process_receive_pkt(): DETECTED DUAL ACTIVE CONDITION!
The configuration on the VSS's interfaces are:
interface giga1/1/YY
des LAN 1
sw acc vlan X
spanning-tree portfast
speed 1000
duplex full
interface giga1/1/YY
des HA1
sw acc vlan X
spanning-tree portfast
speed 1000
duplex full
interface giga2/1/YY
des LAN 2
sw acc vlan X
spanning-tree portfast
speed 1000
duplex full
interface giga2/1/YY
des HA2
sw acc vlan X
spanning-tree portfast
speed 1000
duplex full
All the interfaces are connected but the infloblox shows an error on the HA2 port.
Thanks
Regards,Yes, we resolved the issue. There was any bug in the VSS IOS but when we change the status Master-backup the vip dind't learnt the new mac.
We configured the mac on the two interfaces manually.
Thank you,
Regards
Maybe you are looking for
-
BT Home Hub 3 + Back To My Mac / Port Forwarding
I've recently got BT Infinity and along with it a BT Home Hub 3 which doesn't seem to be playing nicely with Back to my Mac. The setup on the Mac side of things is correct and I can see my remote computer but I just can't connect to them, or vice ver
-
How to enlarge font in ios6 for mail
How to enlarge font in ios6 for mail? Email was easier to read on ios5. I can't find the font setting on ios6.
-
I need to know if free account holders will be able to collaborate on forms that have been shared
I need to know if free account holders will be able to collaborate on forms that have been shared with them and if there will be an Enterprise version available for Adobe Formcentral.
-
Routing change idoc in SAP LOIROU01/02
Hi All, Has anyone used routing idoc LOIROU01/02 for change routing and allocate operations for BOM in SAP using we19 test tool. If so, please give me the minimum fields need to pass in we19 for LOIROU01/02 idoc to allocate an operation to a BOM comp
-
How do I keep alignment of a grouped logo based on four elements?
I created and aligned a logo based on four letters. Afterwards I grouped them. The alignment is correct. But if I copy the group and place it at a different location, the alignment falls slightly out of place. What do I need to do in order to keep th