5s phone makes a loud sound and vibration when talking on the phone. Any advice on this?

Need help with this.. iPhone 5s makes a loud sound and vibration while talking. So bad you have to hang up and call back. I have been to Apple and they have replaced the phone 3 times and still having the same problems

My 5s did exactly as you describe only on the left side of the display.
I exchanged mine as this is unacceptable and does not bode well for long term durability (on the creaky units).
You have 30 days I think for defective units. Better make an appointment with support and get it noted for the record or replaced.

Similar Messages

  • I dropped my phone in a toilet, the sound and vibrate are working but the screen will not turn on, what should I do?

    I dropped my phone in a toilet, the sound and vibrate are working but the screen will not turn on, what should I do? do I just need a new screen or what? I'm freaking out here

    Don't freak out, just get over it. It's probably done.
    What should I do if I drop my phone in the toilet?
    Apple may offer you an refurbished iPhone in exchange for yours, for about half the cost of a new one.
    I wouldn't be too specific about just how it got wet

  • Photo Stream issue.  Photo Stream shows 263 photos when viewed on the iMac, 289 when viewed on the iPad and 327 when viewed on the iPhone.  How can this be?

    Photo Stream issue.  Photo Stream shows 263 photos when viewed on the iMac, 289 when viewed on the iPad and 327 when viewed on the iPhone.  How can this be?  Tried shut down on all devices, reboot and the results are the same.

    Photo Stream issue.  Photo Stream shows 263 photos when viewed on the iMac, 289 when viewed on the iPad and 327 when viewed on the iPhone.  How can this be?  Tried shut down on all devices, reboot and the results are the same.

  • Pixma mg5220 has error code 5012, makes a loud sound and won't work.

    I have a pixma mg5220 all in one printer. Error code 5012 shows and a loud sound occurs. Running windows8.1 on hp smarttouch 15 812, MIGHT BE b12  It's hard to read. This happens rarely, but when it does, I don't know when it will start to work again. Any suggestions, please?

    Hi roxyoung56, To try and resolve the error, please turn off the printer, unplug the power cord and wait for at least 10 minutes, then reconnect the power cord and turn the unit back on again.  If the error still displays, the printer will require servicing.  Please call or email us at one of the methods on the Contact Us page to obtain your servicing options.

  • HT5364 My Autofill will not work anymore the popup turns dark grey and will not fill in the blanks, any insight on this?

    Hi, my autofill has stopped working, it pops up and when I click on it, it turns dark grey and locks on the screen. Any ideas?

    https://discussions.apple.com/message/23636688#23636688

  • The problem of sound and vibration assitant wiht labview 8.6

    when importing lavview vis into the sound and vibration assistant,  i got the error as follows:
    LabVIEW:  The software installed on this computer does not support the file format you requested. The Storage VIs access files through plug-in libraries LabVIEW and DIAdem install. Visit ni.com to download the library you need.
    how can i solve it?

    Can you please describe the procedure you are following to reproduce this error?
    File>>Import can be used to import snapshots from other projects or logs from other projects or (*.tdms) files.
    The 'Run LabVIEW 8.6 VI' Step can be used to run LabVIEW VIs from the Sound and Vibration Assistant. Consult the help as there are a number of steps that must be followed to use this feature.
    Does your VI perform file I/O? What versions of Sound and Vibration Assistant are you using? Can you post your project and built LabVIEW VI?
    Doug
    NI Sound and Vibration

  • Sound and Vibration toolkit for vibration analysis

    Hi guys! I am new to Labview. I am trying to use Sound and Vibration toolkit to analyse the accelerometer signal mounted on a motor through myRio. The analysis are spectral map, order tracking, power spectrum, order spectrum etc. But nothing can be seen from the output graph. The only result I get is from vibration level.
    Attached is a screen shot of my vi and actual vi file. Am I doing it correctly? I really need your help guys....
    Thanks.
    Attachments:
    Vib.vi ‏384 KB

    SK,
    You have serious problems in your File.VI.  Why are your writing to your file and then reading it right back?  Worse, there is no guarantee that the File write will actually occur before the File Read.  You have a race condition set up there between those two Spreadsheet File VI's.
    If you want to maintain a history of whatever has already been written to the file, you should be building it into an array and storing in a shift register.  Even if your File.vi would by chance work the way you want it to, storing data in the file system is much slower than maintaining your data in memory.
    As for your while loop, it is going to run as fast as it can with respect to all the functions occurring inside of it.  Is it possible you are getting 14 iterations of that while loop for each frequency step that is occurring?
    Message Edited by Ravens Fan on 07-25-2009 01:35 AM

  • Sound and Vibration pallet is only for ...

    Hi,
             I installed Labview on my system and I saw Sound and vibration Pallet. Now, I am working with 4610 accelerometer through USB 6008 and analyzing the Voltage levels in labview. I have a doubt that the sound and vibration pallet is only for when using NI sound and vibration kit or can I use those options in this project.

    in a loop - capture a waveform (4096 points for example) from your accelerometer - analyze it, and then output a serial command with the adjustment based on your analysis. 
    repeat the loop until some measurement is met - the serial device is stable, for example. 
    Preston
    Preston Johnson
    Principal Sales Engineer
    Condition Monitoring Systems
    Vibration Analyst III - www.vibinst.org, www.mobiusinstitute.com
    National Instruments
    [email protected]
    www.ni.com/mcm
    www.ni.com/soundandvibration
    www.ni.com/biganalogdata
    512-683-5444

  • Sound and Vibration Toolkit with NI-SCOPE AND NI-FGEN

    Hi,
    I would like to use the Sound and Vibration Toolkit with the NI-FGEN and NI-SCOPE,specifically the stepped sine analysis. The stepped sine VI's are compatible with only DAQmx and not NI-SCOPE and NI-FGEN,right?
    Any way around this?

    Hi there,
    Firstly I assume you mean Swept sine and not stepped!?
    This is the closest thing I could find:
    http://zone.ni.com/devzone/cda/epd/p/id/3347
    I had a look for you and there is nothing that works with a swept sine in FGEN or SCOPE natively that we supply.  However I do believe that a lot of the functionality could be programmed in FGEN and SCOPE vi's.
    You would however need to make copies of all the Swept Sine VI's and replace all DAQmx calls and property nodes with the appropriate SCOPE/FGEN vi's.
    Not a short answer I'm afraid and I can't guarantee that all the functionality is going to be there.
    Sorry its not a better answer.
    AdamB
    Applications Engineering Team Leader | National Instruments | UK & Ireland

  • How to reset Sound and Vibration Spectral map

    Hi,
    I want to create a Campbell diagram for a rotating machine, in live (while the machine is rotating).
    This diagram is basically a graph of the spectral content a a signal (Hz), versus the rotation speed (RPM).
    I've found an express VI that seems to do what i want to do (Spectral Map, in the Sound and Vibration toolkit). The output of this VI is buffered so that it can run in live (The buffer vi is also a vi that comes from the Sound and Vibration toolkit).
    The block diagram of my complete process is attached to this message, sorry it's a bit messy.
    On the first run, this VI works as expected: as the machine is running up, the graph is filling up. Now if I want to make a second run-up, i need to first reset the VI. However once the vi has been reset, it won't ouput anydata!
    I've tried different combination:
    - Reset  "Waterfall and Campbell.vi" and the buffer
    - Reset only the buffer
    - Reset only the "Waterfall and Campbell.vi"
    None of them work, the colormap stays black. 
    So does anyone know how to use this express vi? I could find an exemple that works with live data and buffering.
    Thanks,
    Regards,
    peper
    Attachments:
    Reset waterfall.png ‏74 KB

    Hi,
    Attached to this post, you'll find a piece of code that replicates the problem I have in my main application.
    If you run the vi with an initial small frequency (the frequency dial up simulates the rotation speed) and then increase that speed, you'll notice that the spectral map gets filled as expected.
    The problem arises when I try to reset the spectral map (=do a new run-up):
    - I set the frequency to a minimum
    - I hit the reset button (the spectral map is emptied as expected)
    - I slowly increase the frequency ===> the spectral map does NOT get filled up anymore. Or it gets filled up like 30 seconds after the run up or gets partially filled up.... in summary there is something wrong with the map each time I try to reset the septral map vi.
    Let me know if you need more information.
    Best regards,
    peper2001
    Attachments:
    Campbell.zip ‏101 KB

  • Need help finding Sound and Vibration Toolkit Example Files

    I need help finding some Sound and Vibration Toolkit Example Files?
    http://www.ni.com/white-paper/3779/en
    From this link you get:  getting_started_otb.llb
    The missing files are:
    OAT Truncate Time Indices.vi
    Speed profile.ctl
    oa_Config Time or RPM Segment.vi
    svl-Complex Datatype Default.vi
    Running Windows 7, LabVIEW 2011, 32bit
    Sound and Vibration Measurement Suite
    Sound and Vibration Toolkit
    Thanks,
    -SS
    Solved!
    Go to Solution.
    Attachments:
    License S and V.png ‏4 KB

    SS,
    You can find these files here:
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Resample Order Tracking\SubVIs
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Tach Process\SubVIs
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Resample Order Tracking\SubVIs
    svl-Complex Datatype Default.vi changes to svc-Complex Datatype Default.vi
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\_NISVFA\_Shared subVIs\Common
    Make sure you are license activated, and you will have to dig through the *vi and relink a subvi.
    Then you should get a white arrow.
    -SS 

  • Where is the asper measurement in Sound and Vibration assistant

    I did a test drive of the Sound and Vibration Suite, liked what it could do, but could only afford the Toolkiit. Now I can't find the Asper (Roughness) measurement in the Toolkit. Is it there? I found the Loudness, Sharpness, etc.

    Hi elrathia,
    I think you are looking for the Sound and Vibration » Sound Quality » SV Aures Roughness function.  It should be included with the toolkit.
    Kyle B  |  Product Support Engineer  |  ni.com/support

  • Dropped my ipod and now it makes a clicking sound and won't turn on at all. is it cheaper to get a new one or fix this one?

    i have tile floors and i dropped my ipod classic flat on its back while it was off. i tried turning it on after that and it now it makes a clicking sound and won't even turn on. all it shows is a dead ipod and told me to go to apple.com/support/ipod. i'm not sure how to fix it or if it's even fixable. or is it just cheaper to get a new one?

    If the phone will not power on try these three things:
    Connect it to your phone charger
    Connect it to your computer and open up iTunes
    Perform a hard reset (Hold down the sleep/wake (top) button at the same time as the home (circle) button for 45 seconds. When the apple appears on the screen let go of both buttons.

  • Keyboard sound and vibration

    Hello I have a Xperia Z1 device and I recently updated it to the new android lollipop but I noticed that when writing the sound and viration are available like it wa in the previous android version. I tried to got to the settings of the xperia keyboard but found nothing about it. Is there a way to make it work on the same keyboard without downloading any new keyborad like google keyboard? I kind of like the original skin.
    Solved!
    Go to Solution.

    Seetings > language and input > Xperia keyboard > scroll down > sound and vibration > you will see both options. 
    @nicolas-ayoub
    "I'd rather be hated for who I am, than loved for who I am not." Kurt Cobain (1967-1994)

  • Average multiple signals together in sound and vibration assistant

    Hello,
    I would like to average octave analysis data from multiple microphone channels together to obtain a single set of octave analysis data to view within Sound and Vibration Assistant (a surface average from the microphones).  I have created an octave averaging vi in LabVIEW to run in SVA, but I get the error that there are no signals in my SVA project to input into my vi.  I have based the input of my vi on code generated from SVA which outputed multichannel octave analysis data, so I don't quite understand why the output from an octave analysis in SVA doesn't match up to the input of my vi.
    I also would like to do this for multichannel power spectrum data, and I have tried creating my own vi for this as well with no success.
    I am using LabVIEW 2011 32-bit along with Sound and Vibration Assistant 2011.
    Any assistance with finding a solution to this problem would be greatly appreciated.
    Thank You,
    Eric Morgan
    Attachments:
    Octave Average.vi ‏13 KB
    Power Spectra Average.vi ‏13 KB

    Hello Jake,
    Thank you for responding to my post.  After recording the raw sound pressure data from my microphones, I placed an Octave Analysis step and a Power Spectrum analysis step in the playback section of SVA, and the outputs of these steps should have served as inputs to the VIs I created (I assume you only looked at the power spectrum averaging VI, as the octave averaging VI accepts a 1D array of clusters of center frequencies and band powers).  I did find that my averaging VIs did not have the correct size of empty array going into the second For loop, so I have corrected this in the attached VI (for averaging the FFT).
    Also, I was able to get my corrected VI for averaging the FFT to work after getting past a little quirk in SVA.  After browsing to my VI in setting up the "Run LabVIEW VI" step, I had to click the "Refresh VI" button before it would let me select a power spectrum as its input.
    I also think I figured out why the octave averaging VI doesn't work.  I think it has something to do with the fact that the output of an Octave Analysis step in SVA can not be used as an input to any other steps within SVA, which makes sense most of the time since once you have performed an octave analysis, there is really no other processing of this data that would ever need done...except for my case of averaging the 10 channels together to obtain the surface average SPL (kind of important when testing according to ISO3744).  If this is the case, I would consider this a bug in SVA, as any output from any step in SVA that can be displayed should be able to be used as an input to a "Run LabVIEW VI" step.
    I agree with you that in the end, it would be easier to do everything in just LabVIEW if I were just collecting data for post-processing at a later date, but when investigating noise issues and collecting mounds of data in the process, SignalExpress makes it a little easier to sift through that data as it is collected/logged while still in our sound lab, which may give us some ideas of different ways to test at that moment and possibly find the cause of our noise issues.
    Thanks again for responding to my post,
    Eric Morgan
    Attachments:
    AverageFFT.vi ‏19 KB

Maybe you are looking for