6248UP - Fabric Interconnect [id], HA functionality not ready

Hello
Having an HA issue with a FI cluster and have not able to find much info.
The error I get (in the subject) leads me the the below URL with 5 steps to check.
http://www.cisco.com/en/US/docs/unified_computing/ucs/ts/faults/reference/2.0/UCS_SEMs.html
Step 1 - Not sure how to check this - Any input on this ?
Step 2 - Have checked and even replaced the cables
Step 3 - Checked and confirmed under Equipments -> Rack-Mounts -> Fex ( 2 x N2K-C2232PP-10GE)
Step 4 - Checked and confirmed under Equipments -> Rack-Mounts -> Servers ( 4 x UCSC-C220-M3)
Step 5 - New installation no active contract as yet.
Anyone had similar issues, any assistance would be appreciated.
Thanks

Step 1
Management all setup with initial setup-script, confirmed in extract from running config below
scope fabric-interconnect a
     set out-of-band ip 172.16.1.4 netmask 255.255.255.0 gw 172.16.1.1
scope fabric-interconnect b
     set out-of-band ip 172.16.1.5 netmask 255.255.255.0 gw 172.16.1.1
scope system
     set virtual-ip 172.16.1.6
Double confirmed via show commands below
CTCPFIHA-A# scope fabric-interconnect a
CTCPFIHA-A /fabric-interconnect # show detail
Fabric Interconnect:
    ID: A
    Product Name: Cisco UCS 6248UP
    PID: UCS-FI-6248UP
    VID: V01
    Vendor: Cisco Systems, Inc.
    Serial (SN): SSI163308YF
    HW Revision: 0
    Total Memory (MB): 16232
    OOB IP Addr: 172.16.1.4
    OOB Gateway: 172.16.1.1
    OOB Netmask: 255.255.255.0
    Operability: Operable
    Thermal Status: Ok
    Current Task 1:
    Current Task 2:
CTCPFIHA-A /fabric-interconnect # scope fabric-interconnect b
CTCPFIHA-A /fabric-interconnect # show detail
Fabric Interconnect:
    ID: B
    Product Name: Cisco UCS 6248UP
    PID: UCS-FI-6248UP
    VID: V01
    Vendor: Cisco Systems, Inc.
    Serial (SN): SSI16330FY1
    HW Revision: 0
    Total Memory (MB): 16232
    OOB IP Addr: 172.16.1.5
    OOB Gateway: 172.16.1.1
    OOB Netmask: 255.255.255.0
    Operability: Operable
    Thermal Status: Ok
    Current Task 1:
    Current Task 2:
CTCPFIHA-A /fabric-interconnect # scope system
CTCPFIHA-A /system # show detail
Systems:
    Name: CTCPFIHA
    Mode: Cluster
    System IP Address: 172.16.1.6
    System Owner:
    System Site:
    Description for System:
Step 2
L1<>L1 L2<>L2 confirmed and new cables tried.

Similar Messages

  • 6248UP Fabric Interconnect Configuration Question

    We are in the middle of integrating VOIP into our enmvironment. The provider is asking for a VM to be built and a router to be connected directly to the VM. Can you integrate a GLC-T module into the 6248UP and connect the router directly to it. Configure the port and have that port provide access to the VM they are requesting? If you can, what should I configure the Interconnect port to be (Server or Appliance)? If this will not work, what will?

    Did you configure the port as 1G first ? btw. which FI are you using ? on a 62xx, each port can be 1 or 10G, on a 61xx, there are some limitations.
    Storage appliance port is used to connect IP storage Systems (NFS, iSCSI,....) not Switches / Routers.

  • Failed:Error disabled - SFP vendor not supported on Fabric Interconnect 6248UP

    We are connecting a FC-uplink on a Fabric Interconnect 6248UP to a MDS9124. On the Fabric Interconnect side we use a 8Gbps SFP (DSpSFP-FC8G-SW) on the MDS9124 side there is a 4 Gbps SFP.This should work when speed is at fixed speed 4 Gbps on both sides (I was told). When the SFP's and cabling is connected I get an error in the UCS manager on the FC-uplink port we are using:
    Failed:Error disabled - SFP vendor not supported.
    I cannot change the speed on the FC-Uplink ( I can only set user-label). The Fabric Interconnect is configured for FC on the last 8 ports and that is where the SFP for the storage is located (port 31).

    I have a similar problem.  I'm using port 1/41 and gets this output
    show system firmware expand | head lines 10
    UCSM:
       Running-Vers: 2.1(3a)
       Package-Vers: 2.1(3a)A
       Activate-Status: Ready
    Catalog:
       Running-Vers: 2.1(3a)T
       Package-Vers: 2.1(3a)A
       Activate-Status: Ready
    sh interface fc 1/41
    fc1/41 is down (Error disabled - SFP vendor not supported)
       Hardware is Fibre Channel, SFP is Unknown(0)
       Port WWN is 20:29:00:2a:6a:7e:7b:00
       Admin port mode is F, trunk mode is off
       snmp link state traps are enabled
       Port vsan is 1
       Receive data field Size is 2112
       Beacon is turned off
       1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
       1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
         0 frames input, 0 bytes
           0 discards, 0 errors
           0 CRC, 0 unknown class
           0 too long, 0 too short
         0 frames output, 0 bytes
           0 discards, 0 errors
         0 input OLS, 0 LRR, 0 NOS, 0 loop inits
         0 output OLS, 0 LRR, 0 NOS, 0 loop inits
       last clearing of "show interface" counters never
    show int fc 1/41 transceiver details
    fc1/41 sfp is present but not supported
       name is CISCO-FINISAR  
       part number is FTLX8571D3BCL-C2
       revision is A  
       serial number is FNS17401NYG    
       FC Transmitter type is Unknown(0)
       FC Transmitter supports Unknown(0) link length
       Transmission medium is Unknown(0)
       Supported speeds are - Min speed: -1 Mb/s, Max speed: -1 Mb/s
       Nominal bit rate is 10300 MBits/sec
       Link length supported for 50/125mm fiber is 80 m(s)
       Link length supported for 62.5/125mm fiber is 20 m(s)
       No tx fault, no rx loss, no sync exists, diagnostic monitoring type is 0x68
       SFP Diagnostics Information:
                                         Alarms                 Warnings
    Is this a firmware problem?

  • UCS 6248 Fabric Interconnect loud fan RPM noise

    Hello,
    Our currently installed 6248 Fabric Interconnect pair are generating a loud FAN noise.
    Is there any way to reduce theirs RPM? So then can be quieter? The server room have proper air conditioning.
    Some logs as bellow:
    FABRIC-A(nxos)# show environment fan detail
    Fan:
    Module  Fan  Airflow        Speed(%)  Speed(RPM)
                 Direction
    1       1    Front-to-Back  60        15428
    1       2    Front-to-Back  60        11065
    1       3    Front-to-Back  60        14835
    1       4    Front-to-Back  60        10997
    2       1    Front-to-Back  60        15000
    2       2    Front-to-Back  60        11134
    2       3    Front-to-Back  60        14835
    2       4    Front-to-Back  60        11065
    Power Supply:
    Module  Airflow        Configured
            Direction      Speed (%)
    1       Front-to-Back  60
    2       Front-to-Back  60
    FABRIC-A(nxos)#
    FABRIC-A(nxos)#
    FABRIC-A(nxos)# show environment
    Fan:
    Fan             Model                Hw         Status
    Chassis-1       UCS-FAN-6248UP       --         ok
    Chassis-2       UCS-FAN-6248UP       --         ok
    PS-1            UCS-PSU-6248UP-AC    --         ok
    PS-2            UCS-PSU-6248UP-AC    --         ok
    Temperature
    Module   Sensor     MajorThresh   MinorThres   CurTemp     Status
                        (Celsius)     (Celsius)    (Celsius)
    1        Outlet     67            58           35          ok
    Power Supply:
    Voltage: 12 Volts
    PS  Model                Input Power       Power     Status
                             Type  (Watts)     (Amp)
    1   UCS-PSU-6248UP-AC    AC     780.00     65.00     ok
    2   UCS-PSU-6248UP-AC    AC     780.00     65.00     ok
    Mod Model                   Power     Power       Power     Power       Status
                                Requested Requested   Allocated Allocated
                                (Watts)   (Amp)       (Watts)   (Amp)
    1    UCS-FI-6248UP-SUP      492.00    41.00       492.00    41.00       powered-up
    3    UCS-FI-DL2             24.00     2.00        24.00     2.00        powered-up
    Power Usage Summary:
    Power Supply redundancy mode:                 Redundant
    Power Supply redundancy operational mode:     Redundant
    Total Power Capacity                             1560.00 W
    Power reserved for Supervisor(s)                  492.00 W
    Power currently used by Modules                    24.00 W
    Total Power Available                            1044.00 W
    FABRIC-A(nxos)#

    UPDATE
    I opened a TAC, then after several reviews of the LOGs and huge sh tech files, we concluded that all was normal. This loud noise is normal   and within in normal operational ranges.
    However as the server room is not fully acoustics proof and located near production  work desks, we managed to get a RMA for the fan modules for the version 2 modules which are MUCH quieter than V1 due new design.
    I have upload both pictures for comparison of the designs.
    Thank You!

  • Fabric Interconnect 6120xp question

    I have two fabric interconnect 6120xp in cluster on one i find the ip in running config and on the partner i dont. It might be due to this i dont get the ipaddress of the fabric interconnect (shows as 0.0.0.0) on my san switch when querying fcns database. Any help is appreciated.
    lhr02-wxp00-fic01-B(nxos)# sh run |inc ip
    ip host lhr02-wxp00-fic01-B 10.255.96.78
      ip address 10.255.96.78/24
    lhr02-wxp00-fic01-A(nxos)# sh run |inc ip
    role name server-equipment
    lhr02-wxp00-fic01-A(nxos)#
    lhr02-wxif-san02#  show fcns database  npv
    VSAN 20:
    NPV NODE-NAME           NPV IP_ADDR     NPV IF  CORE SWITCH WWN         CORE IF
    20:14:54:7f:ee:04:c8:01 10.255.96.78    fc2/4   20:00:54:7f:ee:07:6e:80 fc1/6
    20:14:54:7f:ee:04:c8:01 10.255.96.78    fc2/2   20:00:54:7f:ee:07:6e:80 fc1/5
    lhr02-wxif-san01#  show fcns database  npv
    VSAN 10:
    NPV NODE-NAME           NPV IP_ADDR     NPV IF  CORE SWITCH WWN         CORE IF
    20:0a:54:7f:ee:03:ee:c1 0.0.0.0         fc2/1   20:00:54:7f:ee:17:eb:80 fc1/3
    20:0a:54:7f:ee:03:ee:c1 0.0.0.0         fc2/3   20:00:54:7f:ee:17:eb:80 fc1/4

    On the FI with the 0.0.0.0 ipaddress  run the sho npv inter info | inc IP.
    Next go into UCSM and select the equipment tab.Then pick the FI in question. On the right select General tab and then Access.
    What is the ipaddress? Does it also show 0.0.0.0 here as well?
    If it does, try changing it to the address you wanted and check it again.
    If that does not work then you can try to erase the config on that FI and reconfiguring it from the begining.
    Verify they it joins the cluster and HA is ready and the ipaddress is available.

  • Fabric Interconnect and storage solutions

    Dear
    Please I would like to clarify a question, is that a solution of storage, such as EMC VNX5300 can be connected directly to a Fabric Interconnect, but would lose functionality when connected to a Nexus 5000 switch. I would like someone to clarify this doubt indicating that functionality is lost when direct connection would be advisable to FI or the Nexus.
    Regards

    In versions of UCS earlier than 2.1, you had the  option to useDirect Attached Storage DAS with UCS. However, you needed a SAN switch connected  to the FI so the switch could push the zone database to the FI. That is,  the UCS platform was not able to build a zone database
    With the release of Version 2.1, UCS now has the  ability to build its own zone database. You can have DAS with UCS  without the need for a SAN switch to push the zoning configuration
    hope this helps

  • Fabric Interconnect ISSU support

    I was asked by many cutomers about ISSU support for the UCS Fabric Interconnect ? They all know, that N5K (without L3 module) supports ISSU. Is it on the roadmap ?            

    Hello wdey,
    This is a different concept, the nexus control plane need keep relationships during the upgrade process.
    In the UCS Fabric Interconnect, you have others tecnologies to provide high avability to the system overall. (fabric failover, UCSM cluster, FC multipath).
    Although the N5K and the FI is almost the same box, the systems running are completly different. The ISSU in the FI is not necessary, as all functions can be transfered to the pair FI that remained running.
    Richard

  • Is there a way to see SAN luns from the UCS fabric interconnect.

                       Hello,
    I have recently added a 3rd and 4th vHBA to a B440 running RHEL5.
    Originally I had 2 vHBAs', and each created a path to 172 luns. (I was multipathed to 172 luns)
    Now I have added two additional vHBA's and my SAN admin assures me he has mapped, zoned and masked all 172 luns to the 2 new vHBA's.
    So, at this time I should have 4 paths to 172 luns....but I don't.
    What I see is 4 paths to 71 luns.
    I still see 2 paths to all 172 luns, but only see 4 paths on 71 of them.
    Its almost like my SAN admin either mapped or masked only 71 of the 172 luns to my 3rd and 4th path.
    Via the RHEL5 OS I have rescaned the FC paths, rebooted, done lsscsi, looked in the lowest level places for what devices are present on my FC channels, always I see 172 devices on the 2 original FC paths and 71 devices on the 2 new FC paths.
    My question is....is there a way to see all devices (luns) accociated with an vHBA from the command line in the Fabric Interconnect?
    My configuration is UCS w 2 FI's, using 8Gb FC connections to Cisco 9500 directors, to an EMC DMX4.
    Thanks in advance,
    Gene

    wdey,
    The link you supplied in your response is the answer.
    You can look at the devices on the FC boot paths, but not while the OS is running.
    I have a test server I could reeboot to try what you have in your document, and it does work.
    Too bad Cisco could not create a linux util rpm that would allow looking down the fabric while running. Im quit sure emulex has this kind of util, called HBAanywhere...at least for solaris.
    In any case, thanks for the link to your article, it was VERY good!
    My problem with seeing a shorter list of luns on 2 of my FC paths may get solved this afternoon by a change my SAN admin is going to make.. If it does I will post the fix.

  • Can the system name of the Fabric Interconnects be changed

    I need to change the system name of the Fabric interconnects
    I have given eg. EDCD
    the FI now have EDCD-A
    EDCD-B
    I need to change it to ... ECCD-A
    ECCD-B..
    is it possible ?

    Shyam,
    You can definitely do it and for sure is not disruptive and take effect right away.    Just go to the Admin tab> All> Management Interfaces> Name > Edit it with what you need > Apply.
    It is so easy and fast that if at the same time you have an SSH session, as soon as you change the name, the system makes the change on your SSH session too.
    Note: There is no need to look for the way to do this on each fabric. The name you are changing is for both FIs and the system will then add the xya-A or xya-B by itself.
    Rate ALL helpful answers.
    -Kenny

  • Input ready query - not ready for input

    I have created the following in IP:
    1. A multiprovider based on an actuals cube (Standard infocube) and a plan cube (realtime - data can be planned not loaded).
    2. An Aggregation level on the multiprovider - containing infoobjects: 0version, employee, WBS element, infoprovider, fiscal year, fiscal year variant, 0currency and 0amount.
    3. A filter on the following infoobjects: employee (=123456), wbs element(XX.XX.XXX.X), version (variable - mandatory; ready for input), fiscal year(2008) and fiscal year variant(XX).
    4. A planning function to copy from version 0 (actual) to version 866 (random Value - Master data exists).
    I have created a query on the multiprovider and set the query properties correctly. I have also created two restricted key figures as follows:
    1. Actual (Restricted by infoprovider = actual; version = 0; fy = 2007; fyvar = XX)
    2. Plan   (Restricted by infoprovider = plan  ; version = input-ready variable; fy = 2008; fyvar = XX)
    I have used all the infoobjects in the agg. level in the query. I am using the same version number (866) on the query selection screen as defined in the filter.
    When I run the query, I can see only the actuals line. The plan keyfigure is not ready for input (although keyfigure properties are set to "Data can be changed using user entries or planning functions).   
    What am I doing wrong which is preventing the plan keyfigure from opening up for planning?
    I have also tried to create an agg. level on the plan infocube with similar settings as above. When I run the query, I get a no data found result - which I think is right because there is no data in the planning cube.
    PS: When I use the wizard in the planning modeler the keyfigure (0amount) can be changed.

    Hi Avya,
    Use a filter on the 0currency, for a particular currency type. (if problem is: currency type keyfigures are not input ready)
    This will mak it input ready.
    **Reward Points for useful answers**
    Regards,
    Naveenan

  • Fabric Interconnect B, management services are unresponsive

    Hi,
    We have configured Call Home option in UCSM and we are getting below error from Call Home option since last Saturday. We have open TAC with Cisco to troubleshoot this error but as per TAC "The error is a transient error from which the fabric interconnects can automatically recover."
    Below is the error messages we are getting
    E-mail-1:
    Subject:
    System Notification from System-A - diagnostic:GOLD-major - 2011-12-27 17:54:09 GMT-00:00 Fabric Interconnect B, management services are unresponsive
    Body Message:
    System Name:System-A
    Time of Event:2011-12-27 17:54:09 GMT-00:00
    Event Description:Fabric Interconnect B, management services are unresponsive
    Severity Level:6
    E-mail-2:
    Subject:
    System Notification from System-A - diagnostic:GOLD-major - 2011-12-27 17:54:09 GMT-00:00 Fabric Interconnect B, management services are unresponsive
    Body Message:
    <?xml version="1.0" encoding="UTF-8" ?>
    <soap-env:Envelope xmlns:soap-env="http://www.w3.org/2003/05/soap-envelope">
    <soap-env:Header>
    <aml-session:Session xmlns:aml-session="http://www.cisco.com/2004/01/aml-session" soap-env:mustUnderstand="true" soap-env:role="http://www.w3.org/2003/05/soap-envelope/role/next">
    <aml-session:To>http://tools.cisco.com/neddce/services/DDCEService</aml-session:To>
    <aml-session:Path>
    <aml-session:Via>http://www.cisco.com/appliance/uri</aml-session:Via>
    </aml-session:Path>
    <aml-session:From>http://www.cisco.com/appliance/uri</aml-session:From>
    <aml-session:MessageId>1058:SSI1442BFRC:4EFA0641</aml-session:MessageId>
    </aml-session:Session>
    </soap-env:Header>
    <soap-env:Body>
    <aml-block:Block xmlns:aml-block="http://www.cisco.com/2004/01/aml-block">
    <aml-block:Header>
    <aml-block:Type>http://www.cisco.com/2005/05/callhome/diagnostic</aml-block:Type>
    <aml-block:CreationDate>2011-12-27 17:54:09 GMT-00:00</aml-block:CreationDate>
    <aml-block:Builder>
    <aml-block:Name>UCS 6100 Series Fabric Interconnect</aml-block:Name>
    <aml-block:Version>4.2(1)N1(1.43q)</aml-block:Version>
    </aml-block:Builder>
    <aml-block:BlockGroup>
    <aml-block:GroupId>1059:Serial Number:4EFA0641</aml-block:GroupId>
    <aml-block:Number>0</aml-block:Number>
    <aml-block:IsLast>true</aml-block:IsLast>
    <aml-block:IsPrimary>true</aml-block:IsPrimary>
    <aml-block:WaitForPrimary>false</aml-block:WaitForPrimary>
    </aml-block:BlockGroup>
    <aml-block:Severity>6</aml-block:Severity>
    </aml-block:Header>
    <aml-block:Content>
    <ch:CallHome xmlns:ch="http://www.cisco.com/2005/05/callhome" version="1.0">
    <ch:EventTime>2011-12-27 17:54:09 GMT-00:00</ch:EventTime>
    <ch:MessageDescription>Fabric Interconnect B, management services are unresponsive</ch:MessageDescription>
    <ch:Event>
    <ch:Type>diagnostic</ch:Type>
    <ch:SubType>GOLD-major</ch:SubType>
    <ch:Brand>Cisco</ch:Brand>
    <ch:Series>UCS 6100 Series Fabric Interconnect</ch:Series>
    </ch:Event>
    <ch:CustomerData>
    <ch:UserData>
    <ch:Email>[email protected]</ch:Email>
    </ch:UserData>
    <ch:ContractData>
    <ch:CustomerId>[email protected]</ch:CustomerId>
    <ch:ContractId>ContractID</ch:ContractId>
    <ch:DeviceId>N10-S6100@C@SSI1442BFRC</ch:DeviceId>
    </ch:ContractData>
    <ch:SystemInfo>
    <ch:Name>System-A</ch:Name>
    <ch:Contact>Name</ch:Contact>
    <ch:ContactEmail>[email protected]</ch:ContactEmail>
    <ch:ContactPhoneNumber>+00-0000000000</ch:ContactPhoneNumber>
    <ch:StreetAddress>Office Address</ch:StreetAddress>
    </ch:SystemInfo>
    </ch:CustomerData>
    <ch:Device>
    <rme:Chassis xmlns:rme="http://www.cisco.com/rme/4.0">
    <rme:Model>N10-S6100</rme:Model>
    <rme:HardwareVersion>0.0</rme:HardwareVersion>
    <rme:SerialNumber>SerialNumber</rme:SerialNumber>
    </rme:Chassis>
    </ch:Device>
    </ch:CallHome>
    </aml-block:Content>
    <aml-block:Attachments>
    <aml-block:Attachment type="inline">
    <aml-block:Name>sam_content_file</aml-block:Name>
    <aml-block:Data encoding="plain">
    <![CDATA[
    <faultInst
    ack="no"
    cause="management-services-unresponsive"
    changeSet=""
    code="F0452"
    created="2011-12-27T23:24:09.681"
    descr="Fabric Interconnect B, management services are unresponsive"
    dn="sys/mgmt-entity-B/fault-F0452"
    highestSeverity="critical"
    id="2036245"
    lastTransition="2011-12-27T23:24:09.681"
    lc=""
    occur="1"
    origSeverity="critical"
    prevSeverity="critical"
    rule="mgmt-entity-management-services-unresponsive"
    severity="critical"
    status="created"
    tags=""
    type="management"/>]]>
    </aml-block:Data>
    </aml-block:Attachment>
    </aml-block:Attachments>
    </aml-block:Block>
    </soap-env:Body>
    </soap-env:Envelope>
    We want to understand that what is the impact of this error and is there anything that we can do to prevent this error? Also want to know what might be the cause get this error?
    Let me know if anything else is needed from my side
    show-tech file uploaded.

    Padma,
    TAC Engineer sent below mail
    Hi Amit,
    I’ve checked through the show tech you’ve uploaded and have not found any indicators of errors for the error message you are seeing.
    As I mentioned in the call, the error is a transient error from which the fabric interconnects can automatically recover from. The recommended action is to wait for a few (10-15min) to see if the error clears automatically. If the error does not clear then we will need to do further troubleshooting. This error on its own is not a cause for worry. As you have HA in your system the management services would have failed over the to the other fabric interconnect and would not affect your system performance.
    We can leave the system under observation for a few days to see if other errors occur concurrently with this error.
    I will upload show-tech logs here, find my reply below
    Is the alert generated only for FI B or both FIs ->> Amit: Alert generated for FI-B only
    Any change in cluster state corresponding to alert time stamp ->> Amit: Unfortunately when this error generating we are unable to see the cluster state because of timing. If you can guide / suggest from any other location I can find the state that will be helpful
    Cluster physical link status ->> Amit: Cluster link is OK
    Does FI have any core dumps ->> Amit: I don't have any idea about this. How can check this ?
    Regards,
    Amit Vyas

  • Info about Cisco Fabric Interconnect 6140 Operating System

    Hello. We're looking for tech specs about Cisco Fabric Interconnect 6140 Operating System. For us is important to know if the os is NX-OS or not.
    Posted by WebUser Federica Rossi

    The underlying OS is built on NX-OS, but there is a lot of software running on top that is the actual UCSM itself.
    The UCSM software controls the NXOS portions directly - there is no ability to actually configure the system from an NXOS level.
    UCS-250-A(nxos)# sh ver
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Software
      BIOS:      version 1.5.0
      loader:    version N/A
      kickstart: version 5.0(3)N2(2.1m)
      system:    version 5.0(3)N2(2.1m)

  • Why start iCloud drive when Yosemite is not ready? Once accidental start iCloud drive, no downgrade option?

    When IOS8 is release there is a simple switch to start iCloud Drive.  It is a nightmare.  My iWork field can no longer be sync with my Mac and Mac Air.
    There is no downgrade method to resume the usual iCloud support.  Yosemite is not ready now.
    There should be a warning for anyone who may not know the link between iCloud drive and Yosemite.
    Why start iCloud drive when Yosemite is not ready for download?

    Give Apple feedback on this at http://www.apple.com/feedback
    Unfortunately the iOS 8 release was made fully functional even though some of the functions are not useable at this time.  That should have been clearer so the user knew not to activate a function that would not work fully.

  • Why would Fabric Interconnects populate in fabric topology?

    If the Fabric Interconnects are configured in End-Host mode, why would it be sending management traffic through an F port link making it populate on our fabric topology.  We don’t have this on our existing Blades centers and would expect that we would be able to suppress this for these UCS interconnect devices.  These devices are not managed by the SAN teams and they would prefer them NOT to appear as though they are.
    Any advice?

    Release notes in 2.0(5a) showed 
    CSCua91672
    The fcoe_mgr hap reset will no longer cause FI reboot.
    http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/release/notes/OL_25363.html
    I am really never on the Fiber Interconnects to execute any CLI commands.  But a memory leak for some other reason would certainly be a possibility. The fact that its own High Availability process causes double reset in its own High Availability architecture is troubling. 

  • 6248U Fabric Interconnect bootloader prompt

    Hi -
    I am setting up a couple of new 6248U Fabric Interconnects. When i console into them I noticed it at the following prompt.
    loader>
    So I would run a dir command and found this in the file listing
    ucs-6100-k9-system-kickstart.5.0.3.N2.2.04b.bin
    so at the prompt I would type boot  ucs-6100-k9-system-kickstart.5.0.3.N2.2.04b.bin
    after that boots I would get the following prompt:
    switch(boot)#
    These are not plugged into any chassis or i/o modules yet. I wante dto pre configure and put the management ip's and cluster ip into these FI's..
    What am I doing wrong

    Thanks for the reply. This is the result I got: (look at the prompt I got on the bottom)
    boot ucs-6100-k9-system-kickstart.5.0.3.N2.2.04b.bin ucs-6100-k9-system.5.0.3.N2.2.04b.bin
    Starting kernel...
    Usage: init 0123456SsQqAaBbCcUu
    INIT: version 2.85 booting
    I2C - Mezz absent
    sprom_drv_init_platform: nuova_i2c_register_get_card_index
    blogger: /var/log/isan.log: No such file or directory (2).
    Starting system POST.....
      Executing Mod 1 1 SEEPROM Test:...done (1 seconds)
      Executing Mod 1 1 GigE Port Test:....done (32 seconds)
      Executing Mod 1 1 PCIE Test:.................done (0 seconds)
      Mod 1 1 Post Completed Successfully
    POST is completed
    autoneg unmodified, ignoring
    autoneg unmodified, ignoring
    S10mount-ramfs.supnuovaca Mounting /isan 3000m
    Mounted /isan
    Creating /callhome..
    Mounting /callhome..
    Creating /callhome done.
    Callhome spool file system init done.
    Checking all filesystems....r. done.
    Warning: switch is starting up with default configuration
    Checking NVRAM block device ... done
    The startup-config won't be used until the next reboot.
    Loading system software
    Uncompressing system image: bootflash:///ucs-6100-k9-system.5.0.3.N2.2.04b.bin
    Loading plugin 0: core_plugin...
    Loading plugin 1: eth_plugin...
    Loading plugin 2: fc_plugin...
    INIT: Entering runlevel: 3
    Exporting directories for NFS kernel daemon...done.
    Starting NFS kernel daemon:rpc.nfsd.
    rpc.mountddone.
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    INIT: Id "sm" respawning too fast: disabled for 5 minutes
    /isan/bin/first-setup: line 1663: /isan/etc/common_defs: No such file or directory
    System is coming up ... Please wait ...
    System is coming up ... Please wait ...
    System is coming up ... Please wait ...
    System is coming up ... Please wait ...
    System is coming up ... Please wait ...
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    /isan/sbin/sysmgr: error while loading shared libraries: libconvertinfra.so: cannot open shared object file: No such file or directory
    INIT: Id "sm" respawning too fast: disabled for 5 minutes
    System is coming up ... Please wait ...
    System is coming up ... Please wait ...
    System is coming up ... Please wait ...
    bash-2.05b#
    bash-2.05b#
    bash-2.05b#

Maybe you are looking for

  • Now that I've successfully downloaded FF 7.0 and the orange rectangle has appeared, I can no longer see my tools, help, etc.

    I downloaded ff7.0 and the orange rectangle appeared but now I can no longer find at the top of the page my tools, help, and other things I need, Might someone be so kind as to assist me? Thank you, Leeflea.

  • Satellite L300D - Upgrade from Vista to Windows 7

    Hello I have Satellite L300D and I want to upgrade my operating system with windows 7. There is one link given but its not working the link is "http://www.toshiba.eu/windows7-upgrade" So can any body help me? thank you

  • Help with this SQL Query please

    How many garments has each dressmaker constructed? You should give the number of garments and the name, house number and post code of each dressmaker. tables; dressmaker contains D_NO, D_NAME, D_HOUSE_NO, D_POST_CODE garment contains STYLE_NO, DESCRI

  • Redistribute tab in ME22n

    Hi All, Could anyone ,please tell me the functionality of redistribute tab in the confirmation tab of the purchase order. What effect this tab has on MD04? Regards Amit

  • IMac keeps rebooting itself

    My company just bought 4 iMac 27" (late 2013) machines that are less than 2 months old. I have an issue where they all reboot at random. Here's what I've already done for each: 1) Reset the SMC 2) Started from OSX Recovery (found no problems on any o