ABAP-HR Creating infotype Problem

Dear All ,
I have created one infotype 9090 . It is working fine . Now I want to add three buttons only in display mode apart from next , previous and overview . I want to standard functionality as it is . How should I go about . Please it is very urgent .

Hi,
An an altrnative create a new Custom Menu and pass the existing three as it is from standard menu and add your new requirements there and call this in your program.
Regards,
Amit

Similar Messages

  • ABAP HR How to create infotype with table control in it like Infotype 0008

    Hi Experts.
    I need help from u guys. My client requirement is to create custom infotype just like 0008 infotype which contain table control to save amount and wage types. I try to create infotype with table control using PM01, but that table control is in display mode only, i almost search every where to create custom infotype with table control but what ever threads in forum all are they unanswered and most of the threads for creating infotype. But i already done with infotype , but my main problem is table control.
    If any one have some suggestion for this please share with me.
    <removed by moderator> i am looking for positive reply.
    Edited by: Thomas Zloch on Aug 30, 2011 12:54 PM

    Hi
    I've created several infotypes with a Table Control and it is always the same story. You have to create a custom Z table to store the Table Control data (if you can have unlimited records), so in the PSXXXX structure you need to add a TABNR field to link the PAXXXX table and the Z one, just like the type table OM infotypes.
    Then in your code you have to control every possible operation, INS, MOD, DEL... and update the Z table accordingly (the standard code won't do that)
    If your TC fields appear in display mode, take a look at the Groups 1 and 3 in your fields, the must be set with the usual values for a PA infotype.
    If you have more questions, just ask,
    Regards

  • Error while creating infotype message no. pg293

    Hi guys,
    I am creating a new infotype after creating the PS structure when i click on generate objects i get an error saying "An internal error has occurred" message no. PG293.
    kindly provide a solution.
    points will be rewarded.
    thanks

    INFOTYPE CREATION WILL BE TAKEN CARE OF THE ABAPER AS RAO SAID
    AS THE OUT PUT WILL HAVE TO SEEN IN ALL THE SERVERS THIS IS A LITTLE BIT TECHNICAL WORK
    Start transaction PM01, Create Infotype, by entering the transaction code.
    You access the Create Infotype screen:
    2. In the Infotype no. field, enter the four-digit number of the infotype you want to create.
    When you specify the infotype number, please remember to enter any leading zeros.
    3. Choose IT characteristics.
    This accesses the Display View “Infotypes”: Overview screen.
    4. Choose Table view   Display   Change.
    This accesses the Change View “Infotypes”: Overview screen.
    5. Create a new entry for your infotype.
    You can create new entries by
    – choosing Edit   New entries or
    – copying an infotype entry with similar characteristics.
    If you want to copy an existing entry, select the entry you want to copy and choose
    Edit   Copy as.
    6. Check the entries in the individual fields.
    Result: You have maintained the characteristics of your infotype.
    Please check the above config for maintaining your infotype in PA30 and also check your entries in T582A & S.
    Edited by: Sikindar on Mar 9, 2008 8:23 PM

  • Would trying to manually load NSS Internal PKSS #11 Module create a problem or would nothing happen without a filename in the load window under Security Devices?

    Would clicking the load button while NSS Internal PKSS #11 Module is selected and accepting the pop-up window without filling in any more information create a problem for the Firefox 8 program?

    Quote from: lcwhitlock on 04-April-14, 13:44:09
    Hello darkhawk,
    Thank you for the recommendation.  I somewhat understand what a MS DOS disk is, but I'm not sure how to go about creating one. I've seen where you can use a program, like Rufus, to create a usb one  - but I'm leery about using 3rd-party programs (especially ones I'm not familiar with). I've come across a couple of 'how-to' tuts, but they didn't clarify what files (if any) I would need to include on the disk (for my particular situation). Right now I don't have any blank cds, nor any extra flash/thumb drives - wish I did, but hadn't needed these for years. There has only been one other time where I needed to re-install Windows, but that was over 15 years ago - I did it through BIOS, reformatting my drives, and then reinstalled via the Windows XP disk. Windows 8 is an entirely different breed, which has left me feeling a bit stumped, at times. If there was a way I could perform it (successfully), similar to the first time I did it years ago, I'd give it a try - but at the same time, I'm a bit reluctant, because if it doesn't work, then I'm stuck without any internet access to get further help.
    Ask and ye shall receive. This should be doable in Windows 7 and Windows 8 on another PC. I recommend using a USB Flash drive like in this tutorial, but I'm sure you could use something else.
    If you want, you could also use Hiren's BootCD to make a bootable CD with many options and programs on it (I keep one, just for certain situations) that will allow you to do the same things.
    http://www.hiren.info/pages/bootcd
    Also very useful for sorting out virus's as long as it's downloaded and made on another PC that is virus free......

  • I would like to upgrade to the next step, but because I have many problems with the version 10.4.11, I'm worried that upgrading would create more problems.

    Due to a misunderstanding with [email protected] in September of 2010, many of my applications and important files were put into the trash during a cleaning.  The trash hadn't been deleted, so a CleanApp rep told me to drag my important files to a folder on my desktop.  They were unable to help me with anymore advice with the exception that if I followed the pathway of the application, I could manually restore it to its proper location. 
    This was asking a lot of me because I didn't have the experience or knowledge of undertaking such a massive restoration.  However, I did the best I could.  What had been put in the trash was not just a few files -- there were hundreds of files or apps that I discovered in the trash.  As I said, this was a misunderstanding.  I was left feeling devastated at what had happened. 
    Since then, my iMac Intel Core Duo has been running on its last legs.  I'm surprised I can even get to my email.  As far as using the software that I bought with my iMac, I can't.  I just do the basics.
    What I have been wanting to do is to upgrade to the next level.  However, I worry that if I upgrade a crippled OS X 10.4.11 Tiger, I would be creating more problems than what I already have.  Do you agree that an upgrade would make matters worse? 

    It won't necessarily make it worse, but may not make it better.  I am not familiar with the utility you usedm though anything that cleans or maintains your Mac should be avoided unless you know what you are doing and what it does.  Probably re-installing software from the official sources (download or CDs) is the best way to ensure missing parts are all replaced.
    If this is a core duo and not a core 2 duo then the highest you can go is Snow Leopard 10.6 Get more information about your computer. Go to the Apple in the upper left corner of any window, then "About This Mac", then "More Info..."  Copy and paste the information here, but omit the serial number and Hardware UUID (if present).

  • Does it create a problem if I only connect the backup external drive every few days for use with Time Machine?  Should I have purchased Time Capsule instead?

    After a near miss with my 4-year old MacBook, I finally wised up and purchased a WD My Passport for Mac to back up my hard drive. I connected the Passport today and have performed the first full backup.  However, I do not wish to keep it permanently connected to the laptop.  Does this create a problem if I only connect the drive every few days?  Should I have purchased Time Capsule instead?

    Hello,
    I don't think it'll cause a problem, but I'd disable/turn off Time Machine before disconnecting, then turn it back on after you connect it again.

  • If I change the nation setting of my iTunes in order to buy a song from the American iTunes store, then change my setting back to the Korean store (where you cannot buy music) will that create any problems with my downloaded content?

    If I change the nation setting of my iTunes in order to buy a song from the American iTunes store, then change my setting back to the Korean store (where you cannot buy music) will that create any problems with my downloaded content? I want to buy an album that I cannot get hold of in Korea, but it is available in the US iTunes store. However since most of my apps are downloaded from the Korean store I'll need to switch back in order to update them. Does anyone know if there are any issues in doing this. I'd rather find out before I spend money, change my store setting back to Korea, and then get told I can't listen to the music because I bought it from the US store and my iTunes is set to the Korean store.
    Cheers.

    You canot easily change your country settings.  The iTunes Store in a country is intended only for use by that country's residents, and only while they are in the country. To use the iTunes Store in a country you need a credit card (or other card type if acceptable in a country) issued in that country, billed to an address in that country, and also be physically present in that country when using the store.  You are also restricted to waiting 90 days between country changes.
    E.g., "The iTunes Service is available to you only in the United States, its territories, and possessions. You agree not to use or attempt to use the iTunes Service from outside these locations. Apple may use technologies to verify your compliance." - http://www.apple.com/legal/itunes/us/terms.html#SERVICE

  • Fetching materials on basis of Division creating perfomance problem

    Hi Experts,
    i am fetching Data from three table like
    select a~matnr a~extwg
    b~charg b~werks b~clabs b~cspem b~cinsm
    c~vfdat
    from mara as a join mchb as b
    on a~matnr = b~matnr join mch1 as c on b~matnr = c~matnr  and b~charg = c~charg
    into table  itab_main
    where  a~spart = p_spart and b~werks = p_werks
    and b~lgort = 'FG01' .
    it is creating perfomance problem
    so my questin is 'is there any index table for mara ?(like vrpma for vbak)'
    so we can get all the material on base of division fast.
    Regards,
    Alpesh
    Edited by: Alpesh on Jun 2, 2009 3:56 PM

    Hi Alpesh,
    How about throwing MARC into the mix. I notice that you are searching with plant, storage location and division. Table MARC has an index on plant named WRK.
    If you join MARA and MARC to first determine all the materials that qualify for the given plant and division combination, you can access table MCHB with material (MARA-MATNR), plant (MARC-WERKS) and storage location (FG01) i.e. the first 4 fields in the primary key of table MCHB.
    I could not test this theory out because in our system we do not have any data in table MCHB. Your select executes quickly on my system.
    Please let me know how this panned out.

  • How to set authorization for only Create infotype record

    How can I set the authorization so that the user can only create Infotype 14,15,2010,2001,2006 but cannot change and delete the record for these infotypes.
    But user has the authorization to create,change and delete other infotypes.

    Hi irene,
    1. For this we have to use the
       authorisation object
      P_ORGIN
    2. It has got the following fields, on which authorisations can be controlled.
    AUTHC     Authorization level
    INFTY     Infotype           
    PERSA     Personnel Area     
    PERSG     Employee Group     
    PERSK     Employee Subgroup  
    SUBTY     Subtype            
    VDSK1     Organizational Key 
    regards,
    amit m.

  • How to create infotype while creating another infotype

    Hi All,
    I have below requirement...
    Whenever user create infotype 0008, infotype 0014 should be created for the wages available in a  Z table.
    I created a dynamic action and call function HR_INFOTYPE_OPERATION. When i debug the routine function successfully executed with sy-subrc eq 0. But when i check the database table, there will be no data for infotype 0014. I am writing the below piece of code, i put the hard code value for testing purpose...if you  have any idea please let me know
    IT_P0014-PERNR = '1000005'.
    IT_P0014-ENDDA = '99991231'.
    IT_P0014-BEGDA = '20071111'.
    IT_P0014-LGART = '1003'.
    IT_P0014-BETRG = 1003.
    CALL FUNCTION 'BAPI_EMPLOYEE_ENQUEUE'
    EXPORTING
    NUMBER = '1000005'
    IMPORTING
    RETURN = RETURN.
    CALL FUNCTION 'HR_INFOTYPE_OPERATION'
    EXPORTING
    INFTY = '0014'
    NUMBER = '1000005'
    VALIDITYEND = '99991231'
    VALIDITYBEGIN = '20071111'
    RECORD = IT_P0014
    OPERATION = 'INS'
    TCLAS = 'A'
    IMPORTING
    RETURN = RETURN
    EXCEPTIONS
    OTHERS = 0.
    COMMIT WORK AND WAIT.
    CALL FUNCTION 'BAPI_EMPLOYEE_DEQUEUE'
    EXPORTING
    NUMBER = '1000005'.
    Please let me know if i am missing any thing.

    Use INSERT command instead of HR_INFOTYPE_OPERATION.It has some issues while calling from Dynamic Actions.

  • How to Create infotype views through pm01

    I need to create a view for infotype 21. There is a tab for creating infotype views in pm01 transaction. but not sure how to use it. There are fields such as 'additional IT' and 'View'. Not sure what needs to be filled in these fields. I have created the structure for my view(PS0955). Can somebody help me out with this?

    Well what I meant by view was to create a new infotype but it won't be maintained in standard way through pa30. It is basically a view (infotype with some subscreen) that will be called on existing infotype screen (in my case IT0021). So instead of modifying the standard infotype 21 screen I can append my desired fields to this through view.
    Well my issue now has been resolved. But now I have yet another issue.
    I want to create my own screen for existing infotype. For that I know that I have to copy the existing standard screen 2000 and rename it to some other number. However, i want to know what is the exact procedure. What are the other steps involved with it. Any body can help?

  • How to create infotype 1001

    Hi experts,
    I am doing some configuration in accouting and an error pops up indicating infotype 1001 is not maintained. As I know very little about HR module so I just try to create infotype 1001 in PA30 but turn out it can not be maintained there. Could any body tell me how to maintain this infotype.
    Thanks,
    Tony

    Hi Tony,
    You can go to PP01, select the otype, type in the objid and create 'Relationships' infotype which is infotype 1001.
    Through transaction OOVK, you can find out what all relationships have to be created for an object. Some of these can be maintained through PP01, some cannot be (selecting the relationship subtype and then allowed relationships -> not maintainable flag).
    Basically, you need to find out that for which relationship (subtype of infotype 1001) it is sayin that 1001 is not maintained. Then you can go and create only that relation in PP01.
    Regards,
    Neha

  • Idoc hrmd_a  doesn't create infotype 0003 automatically

    Hello !
    When a new Person is created in One R3 system -
    we send It's infotypes to another R3 system
    with idoc hrmd_a.
    We send only these infotypes :
    0000,0001,0002,0006,0105,0041,0900.
    We expect infotype 0003 to be created automatically in the new system ,
    but it does not happen and for that reason
    The Person is not created fully in the target system.
    only 0000,0001,0002 are created and for each of the other infotypes we got a message like this :
    "You have tried to create infotype XXXX for the following object: plan version 01, object type P, object ID 00XXXXXX. However, the object does not exist.
    PA objects exist if infotypes 0000, 0001, 0002, and 0003  have been created. "
    How can we make 0003 infotype to be created automatically
    without sending it by the Idoc ?
    Is there a flag in the idoc declarations or
    a customization we can fill to make this happen ?
    Thanks ,
      Nitzan S.

    Hi Nitzan,
    I don't think there is any easy way to get 0003 infotype being created automatically on idoc input. At least I have none in Release 4.6 c.
    Why not send it? IMHO there is no sensitive data in it? Besides there are ways to manipulate that data when replicated via ALE.
    If you really need that infotype to be created, you could check EXIT_SAPLRHA0_003 of RHALE001 via transaction CMOD. There you can code your requirements in ALE-user-exit.
    Regards
    Herbert
    Message was edited by: Herbert B.

  • Error when create Infotype 0007-Planned Working Time of Personnel data

    Hi Experts,
    I'm creating Infotype 0007-Planned Working Time for Personnel data then having a error below.( I created Work schedule rule and Gennerated it).
    Feature structure cannot be recognized, please see documentation
    Message no. P0568
    Diagnosis
    Cause 1:
    The structure of the feature is not saved in the feature directory.
    Cause 2:
    The feature structure is not defined in the program that reads the feature.
    Cause 3:
    The feature that the program expects does not match the actual feature structure.
    Procedure
    Cause 1:
    Please advise your system administrator that all features must be regenerated. Please note that this generation must take place in client 000 first, and then in all other clients (report RPUMKF00 or the Generation function in the feature maintenance transaction (transaction PE03)).
    Cause 2:
    The feature structure must always be defined in the program reading the feature (see documentation for program RPUMKC00).
    Cause 3:
    Please contact your system administrator
    I did using T.Code PE03 in Client 000 but I don't know what is Features?
    Please tell me how solves it ?
    Thanks so much.
    Dungnv

    infotype 0007 reads two features
    SCHKZ  - Default value for Shift indicator
    TMSTA     DEFAULT VALUE FOR TIME MANAGEMENT STATUS
    Please have a look at both these features

  • Every time an email comes in it's preceded by two telephone rings. I don't know what I did to create the problem so I don't know how to resolve it. HELP PLEASE!!!

    Every time an email comes in it's preceded by two telephone rings. I don't know what I did to create the problem so I don't know how to resolve it. HELP PLEASE!!!

    settings >>>>notifications>>>>Mail >>>>allow notifications >>>off  (your choice )
    settings>>>sounds>>>new mail>>>>none  ( will kill rings )

Maybe you are looking for