ABC indicator removal
Hi
Having some clarification cycle count indicator...
1) How to mass remove the ABC indicator set for the material master ?
ie, mass change from a indicator specified to blank field.
I believe this is kind of basic qsnts, really appreciated your support.
Thanks
MM
Hi,
Just tested this out in my system and it works. Here's what I did.
1) Execute MM17
2) Choose Fields Tab --> Search for MARC-ABCIN and then highlight and execute
3) Enter Material and Plant then execute
4) At the new values line, leave it blank then, click on carry out mass change button
5) Save
Even with CC Fixed indicator checked, I am still able to change the value to blank.
Hope this helps
Regards,
Nazrin
Similar Messages
-
Vendor report for ABC indicator field
Hi All,
My client uses field ABC indicator in the purchasing data view of the vendor master. They want to have reports based on this field.
Are there any standard reports in SAP which can give total purchased value and quantity for a vendor with specific value of ABC indicator?
Regards,
VishalHi Vishal
you can try with T code ME81N
link:[http://help.sap.com/saphelp_45b/helpdata/en/75/ee128c55c811d189900000e8322d00/frameset.htm]
Hope this helps
Regards
Vikrant -
Updation of ABC indicator in Material Master
Hi,
For ABC analysis, I carried out it according to T_code MC40(Usage value). I got the category of material. For eg "A".But how the ABC indicator updates in Material master.Because I couldnt get indicator in MRP1 view.
Whats the right way? Pls guide me.
Thanks,
Goraksh.Hi,
Update of consumption is based on movement type, and you can decide which movement types should have or have not consumption updating.
Check in transaction OMJJ if the movement types in question have indicator "Consumption posting" (field V_156_VC-KZVBU) as marked.
If it is the case, consumption is updated, opposite for un-ticked.
Hope that helps.
Thanks. -
Hi PM gurus
I have a problem. I change a ABC Indicator value of Functional Locations to A via transaction IL02. However, when i get a report with transaction IW38, I dont see A value in ABC Indicator field in some of the Functional Locations. I am sure I have changed and saved the value of that field. What may be the reason? Do you have any idea? Thanks in advancecheck the change history, maybe someone else has changed it again.
-
ABC indicator in Material Master
Hi experts,
Could you please let me know if the ABC indicator field used in MRP1 view is Plant dependant or Plant independant?
We have 2 plants. So should we set this ABC indicator seperately for Plant 1 & Plant 2?
Thanks,
PriABC INDICATOR:
Indicator that classifies a material as an A, B, or C part according to
its consumption value. This classification process is known as the ABC
analysis.
The three indicators have the following meanings:
o A - important part, high consumption value
o B - less important part, medium consumption value
o C - relatively unimportant part, low consumption value
So we can say that this information in Material master is plant specific (Plant dependent)
Logically if we think the material which is of high importance and have high consumption in one plant need not have to be important with same level of consumption in another plant.
Rerward if it is helpful
Regards
Pavan
So when doing the bifercation of the materials based on their importance it is plant which is of utmost importance -
ABC Indicator for Equipment & Functional Location Same or Different
Hi All,
We can find ABC indicators in both Equipment & Functional Location (FL) master data.
Q. Please tell me....whether these fields are different for Equipment & FL or same??
Problem is that I could see the same field name ABCKZ for both Equipment & FL in tables V_EQUI & ILOA respectively.
SundarHi Sunder
*The ABC indicator can be entered in equipment as well as functional locations.*
An indicator that is assigned by the procedure of ABC analysis.
The following ABC indicators are possible:
A - Important
B - Less important
C - Relatively unimportant
According to these criteria, "A" materials are those materials that are of greatest importance for the production operations of a company.
Examples of use for ABC indicators are vendor master records, material master records, and master records of *technical objects.*
So ABC indicator is same for equipments and Functional LocationBUT value may be diferent
Regards
Jitender Suhag -
ABC indicator for project stock
Is there a way to run MIBC and assign abc indicator to project stock that is not valuated or even for the part numbers to show up on this list? What needs to be done in order for this to show up on the report? IS there a way to make it valuated and but not company own stock valuation?
Hello Kimberly,
MIBC report will show the list of material based on the Consumption or Requirement and it will suggest ABC indicator considering the both factor.
The Project stock can be managed as valuated project stock or nonvaluated project stock.
For more details, please have a look on the following link
<a href="http://help.sap.com/saphelp_46c/helpdata/en/4d/2b92c943ad11d189410000e829fbbd/frameset.htm">Project Stock</a>
Hope this helps.
Regards
Arif Mansuri -
Mandatory check for ABC Indicator- MRP1 view
Dear All,
I want to make ABC Indicator mandatory for ROH material type and to the particular plant. How can I achieve this?
I tried to change in customization (Change 'Field selection for data screens' ), but its effecting other fields also. because in the field selection group 51 has so many other fields.
Should I have to create new field section group & field reference Or any other way? Need your valuable guidance.
Thanks.hi Vijay,
if you want to control it thru configuration then you have to create a new field selection group and then you can make the ABC indicator mandatory.
you can also use the user exit in material master which will throw an error message at the time of saving of material master if the ABC indicator field is blank.
Regards,
Anoop singh -
ABC Indicator field in PM MODULE
Hi gurus,
I have a problem. I change a ABC Indicator value of Functional Locations to A via transaction IL02. However, when i get a report with transaction IW38, I dont see A value in ABC Indicator field in some of the Functional Locations. I am sure I have changed and saved the value of that field. What may be the reason? Do you have any idea? Thanks in advance....Hi,
The value shown on IW38 will be the ABC Indicator as recorded on the order. When the order was created this value would have defaulted from the functional location. If you later change the functional location value, that is not updated on existing orders.
You can change the ABC Indicator value directly on the orders location tab (provided it is not completed).
-Paul
Please use [Enterprise Asset Management (EAM)|Enterprise Asset Management (SAP EAM); forum for PM/CS specific topics -
BDC- To add ABC indicator in MM02-- MRP1
Hi,
I am working on BDC- To add ABC indicator in MM02--> MRP1.
Problem -->
In some material+ plant - Reorder point is there. In this case I need to take additional 'BDC_okcode' for ENTER.
HOW CAN I DO THIS?
I tried it with 'Select statement' between the Perform statement, but it's not working?
IF wa_file-matnr IS NOT INITIAL.
PERFORM bdc_dynpro USING 'SAPLMGMM' '0060'.
PERFORM bdc_field USING 'BDC_CURSOR'
'RMMG1-MATNR'.
PERFORM bdc_field USING 'BDC_OKCODE'
'=ENTR'.
PERFORM bdc_field USING 'RMMG1-MATNR'
wa_file-matnr.
PERFORM bdc_dynpro USING 'SAPLMGMM' '0070'.
PERFORM bdc_field USING 'BDC_CURSOR'
'MSICHTAUSW-DYTXT(11)'.
PERFORM bdc_field USING 'MSICHTAUSW-KZSEL(11)'
'X'.
PERFORM bdc_field USING 'BDC_OKCODE'
'=ENTR'.
PERFORM bdc_dynpro USING 'SAPLMGMM' '0080'.
PERFORM bdc_field USING 'BDC_CURSOR'
'RMMG1-WERKS'.
PERFORM bdc_field USING 'RMMG1-WERKS'
wa_file-werks.
PERFORM bdc_dynpro USING 'SAPLMGMM' '4000'.
PERFORM bdc_field USING 'BDC_OKCODE'
'=BU'.
PERFORM bdc_field USING 'MARC-MAABC'
wa_file-maabc.
SELECT SINGLE minbe INTO v_minbe FROM marc
WHERE matnr = wa_file-matnr
AND werks = wa_file-werks.
IF v_minbe GT 0.
PERFORM bdc_field USING 'BDC_OKCODE'
'/00'.
ENDIF.
ENDIF.
CALL TRANSACTION 'MM02' USING it_bdcdata MODE p_mode MESSAGES INTO it_msg.Hi,
Try to use Bapi and see ..Please find the sample code.
LOOP AT t_itab INTO wa_itab.
CALL FUNCTION 'CONVERSION_EXIT_MATN1_INPUT'
EXPORTING
input = wa_itab-matnr
IMPORTING
output = wa_headdata-material
EXCEPTIONS
length_error = 1
OTHERS = 2.
IF sy-subrc <> 0.
MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
ENDIF.
prepare the follwing structres ( plantdata,headdata, plantdatax) .
* Select the MRP view
wa_headdata-mrp_view = 'X'.
* Call the Bapi to create the MRP view.
CALL FUNCTION 'BAPI_MATERIAL_SAVEDATA'
EXPORTING
headdata = wa_headdata
plantdata = wa_plantdata
plantdatax = wa_plantdatax
TABLES
returnmessages = t_return.
ENDLOOP
Regards,
Nagaraj -
Equipment ABC indicator mapping
Hi PM Gurus
Need some help I need to fill up three fields in technical object master data which is existing.
1. Technical object type u2013 ( like rotating , fabricated , instruments etc..)
2. Catalog profile u2013 ( sub classification based on identified object type like pump in a rotating object type)
3. ABC indicator u2013 ( should be identified based on established parameters like frequency of failure and repair cost)
For 1&2. Technical object type - i had used the EQUI - long text field and if any match found like pump then it was identified as rotating equipment and pump catalog profile fileds are filled up . (Any best practices for mapping similar to this approach)
Any best practices / Mapping of fields to obtain the frequency of failure (like <1 year, 1-3 year , 3-10 year) & Repair cost of technical object ( based on this ranking of ABC indicator is to be carried out)
ThanksHI
A, B, C indicators are used to classify technical objects according certain criteria such as importance from production point of view say A- denoting those objects failure of which causes production loss & critical to the process & multiple implications in process
B - causes partial production loss
C-causes no production loss (have standby)
This indicator has to be assigned to technical object prior to transactions & you will get the failure analysis once you do transactions over a period of time. After wards you will come to know about the failure frequency & it will not follow any pattern. Hence failure to be analysed based on object class/object type/damage/cause/object part & also location & manufacturer etc.
Shakti -
Difference "abc indicator" in MRP1 & "cc phys inv ind" in plant data stor1
Hello,
we want to do cycle counts and I noticed that there are two different field in the material master for that.
I think they have a different purpose?
"ABC indicator" field in MRP1 view
and
"cc phys inv ind" field in plant data/ stor 1 view
Can somebody please explain the difference?
Thanks
AnneMC40 and MC41 dont need customizing, setting can be made in selection screen.
ABC analysis for cycle count MIBC needs customizing.
In MRP1 view the field name is MARC-MAABC while on storage location view the field name is MARC-ABCIN.
The one on storage location view is used for cycle count, and includes ABC and D, and is caclulated by MIBC transaction.
The indicator in MRP1 view is calculated and updated by MC40 and MC41 transaction
MICN is the only one that can update the indicator used for cycle counting.
if you execute both transaction with same settings, then there should be the same result.
However, pretty often the cycle count indicators are precalculated by MICN based on consumption, but then individual items are changed to get a different indicator for specific reasons.
You may have a low value item, which is very important for your processes.
Based on consumption values it may get indicator C, but if you have differences on that item then it is a critical factor for your business, hence you want count it more often, thus you would manually change it to B or even A. (which can be done directly from the MICN report)
The focus on both indicators can be equal in many companies, but may also be different in other companies, hence you need 2 indicators for ABC analysis -
Authorization object for ABC Indicator
HI Experts,
May we know what is the Authorization Object we can use for ABC Indicator in Equipment?
Thanks,Hi bonsai,
Sorry for delay response..
Authorization keys which you can use to set up authorization checks when you manually set or delete a user status.
After creating the status profile.create individula authorization key in the lower menu node where u hv created the User status .
Then assign the authorization key to the each status codes(Last column of the status profile).(Crete authorization key same as the status codes).
Then maintain the authorization key value in the field BERSL where u want to give the authority for change /Delete user status.
Regards
Dhiren -
Where a system saved a old ABC indicator
Dear expert Hi
We are working in our company with ABC indicator for cycle counting , Trans: MIBC
I will need to create a new Query when we can see what is the old ABC indicator and what is the new ABC indicator after we update a indicator with MIBC
Please you can explain where a system saved old ABC indicator (TABLE)?
Regards
DianaHi,
For a material master the ABC indicator is mentioned in the MM01 -MRP1 view screen
The table name is : MARC
where as in MBIC t.code if you change the CC indicator the CCindicator changes is indicated inthe same t.code in X. it is not stored in Table. It is stored in a structure.
actually the ABC indicator is stored in table MARC only
Regards
G.Ganesh Kumar -
Linking Priority and ABC indicator
Gentlemen,
Here i have an interesting requirement. My customer require to set the priority of notification based on the equipment criticality, ie based on the ABC indicator.
How to link these two things ( Priority in notification and ABC indicators of Tech object ) object and make it default.
Please throw your valuable ideas.
Regards
Srinivasan MadaswamyDear Pete,
Yes, this default data can be allowed to get into notification while saving.
The only criteria is to have automatic population of priority field based on criticality of equipment.
Regards
Srinivasan Madaswamy
Maybe you are looking for
-
Cisco ISE functionally and license
HI. I wanna configure the following on Cisco ISE 1.2.1. Self-registration portal for guests (SSID: guests) 802.1x user certificate check (Cisco NAM supplicant) for employees (SSID: Corporate) (EAP-TLS) Self provisioning portal (to deploy BYOD certif
-
.MP4 in timeline of Adobe Encore CS6 (DVD)
Hey there, I have created my DVD menu with an mp4 inside the timeline of my Encore project... I contacted support and they told me that most recent DVD players can support this file.. I am wondering if anyone has experience with this case.. Do most D
-
Print server (EA6500)
hello I own cisco router - EA6500 - which works as a prin server I use apple/mac computers and everything is workins fine the problem is that i cannot print anything when using ipad/iphone both devices cannot see the printer I use brother 7030 printe
-
Root Handles (icons next to the node) not visible in TreeTable
Hi i am using the example provided at www.java.sun.com for TreeTable. I have a tree table and when i add new nodes the data is visible in the table but the handles are not visible. I don't know how to resolve this problem. Below is my code where i'm
-
How to make a column as command link
hi, how to make a column as command link.i want to make a table column as a command link so that a popup will come.please let me know. thanks in advance